TECHNICAL MANUAL
INVERTER RESIDENTIAL AIR CONDITIONERS
(Split system, air to air heat pump type)
Wall mounted type Floor standing type Ceiling concealed type
SRK50ZJ-S
SRF25ZJX-S
SRF35ZJX-S
SRF50ZJX-S
SRR25ZJ-S
SRR35ZJ-S
SRK20ZJX-S
SRK25ZJX-S
SRK35ZJX-S
SRK50ZJX-S
SRK60ZJX-S
Ceiling cassette-4way compact type
FDTC25VD
FDTC35VD
'10 • SR-T-091D
1. SPECIFICATIONS
(1) Wall mounted type (SRK)
Adapted to RoHS directive
SRK50ZJ-S
Model
Item
Indoor unit SRK50ZJ-S
5000 (1600 (Min.)
5800 (1600 (Min.)
1 Phase, 220
Outdoor unit SRC50ZJ-S
Cooling capacity (1)
Heating capacity (1)
Power supply
W
W
~
~
~
5500 (Max.))
6600 (Max.))
240 V, 50Hz
Cooling
Heating
Cooling
Heating
1.55 (0.40
~
2.10)
2.20)
Power
consumption
kW
A
1.59 (0.42~
7.1 / 6.8 / 6.5 (220/ 230/ 240 V)
7.3 / 7.0 / 6.7 (220/ 230/ 240 V)
7.3 / 7.0 / 6.7 (220/ 230/ 240 V)
3.23
Running
current
Inrush current
Operation
data (1)
Cooling
COP
Heating
3.65
Sound level
Power level
Sound level
Power level
dB(A)
dB
Hi : 46 Me : 37 Lo : 26
51
Cooling
Heating
61
Hi : 45 Me : 37 Lo : 31
61
61
Noise
level
dB(A)
dB
53
63
Exterior dimensions (Height x Width x Depth)
mm
294 x 798 x 229
640 x 800 (+71) x 290
Exterior appearance
(Munsell color)
Fine snow
( 8.0Y 9.3/0.1 ) near equivalent
Stucco white
( 4.2Y 7.5/1.1 ) near equivalent
Net weight
kg
kW
kg
9.5
—
42
Compressor type & Q'ty
Motor (Starting method)
5RS132XAB21 (Rotary type) x 1
0.90 (Line starting)
—
Refrigerant oil
0.37 (FV50S)
R410A 1.35 (Pre-Charged up to the piping length of 15m)
Louver fins & inner grooved tubing M fins & inner grooved tubing
Refrigerant
equipment
Refrigerant (4)
Heat exchanger
Refrigerant control
Deice control
Fan type & Q'ty
Motor
Capillary tubes + Electronic expansion valve
Microcomputer control
Tangential fan x 1
38
Propeller fan x 1
34
W
Cooling
Heating
Hi : 11.3 Me : 7.8 Lo : 5.3
Hi : 13.5 Me : 10.2 Lo : 7.5
Not possible
36.0
Air handling
equipment
Air flow
CMM
36.0
Fresh air intake
—
Air filter, Quality / Quantity
Polypropylene net (washable) x 2
—
—
Shock & vibration absorber
Electric heater
Cushion rubber (for compressor)
—
—
—
—
Operation switch
Wireless-Remote control
Microcomputer thermostat
Operation
control
Room temperature control
Operation Display
RUN : Green, TIMER : Yellow, HI POWER : Green, 3D AUTO : Green
Compressor overheat protection, Overcurrent protection,
Safety devices
Frost protection, Serial signal error protection, Indoor fan motor error protection,
Heating overload protection (High pressure control), Cooling overload protection
Refrigerant piping size (O.D)
Connecting method
mm
m
Liquid line : 6.35 (1/4") Gas line : 12.7 (1/2")
φ
φ
Flare connecting
Liquid line : 0.53
Gas line : 0.40
Attached length of piping
—
—
Installation
data
Insulation for piping
Necessary (Both sides), independent
Max. 25
Refrigerant line (one way) length
m
A
Vertical height difference between
outdoor unit and indoor unit
Max. 15 (Outdoor unit is higher)
Max. 15 (Outdoor unit is lower)
Drain hose
Connectable (VP16)
Power cable
—
Recommended breaker size
16
Size x Core number
Connecting method
1.5mm2 x 4 cores (Including earth cable)
Terminal block (Screw fixing type)
Connection wiring
Accessories (included)
Optional parts
Mounting kit, Clean filter (Allergen clear filter x 1, Photocatalytic washable deodorizing filter x 1)
Interface kit (SC-BIKN-E)
The pipe length is 7.5m.
Note (1) The data are measured at the following conditions.
Item
Indoor air temperature
Outdoor air temperature
Standards
DB
WB
19˚C
—
DB
35˚C
7˚C
WB
24˚C
6˚C
Operation
Cooling
Heating
27˚C
20˚C
ISO-T1, JIS C 9612
(2) This air-conditioner is manufactured and tested in conformity with the ISO.
(3) The operation data are applied to the 220/230/240V districts respectively.
(4) The refrigerant quantity to be charged includes the refrigerant in 15m connecting piping.
(Purging is not required even for the short piping.)
RWA000Z225
B
ꢁ
'10 • SR-T-091D
Adapted to RoHS directive
SRK20ZJX-S
Model
Item
Indoor unit SRK20ZJX-S
2000 (900 (Min.)
2500 (900 (Min.)
1 Phase, 220
Outdoor unit SRC20ZJX-S
Cooling capacity (1)
Heating capacity (1)
Power supply
W
W
~
~
~
3100 (Max.))
4300 (Max.))
240 V, 50Hz
Cooling
Heating
Cooling
Heating
0.35 (0.19
~
1.00)
0.70)
Power
consumption
kW
A
0.45 (0.23~
1.9 / 1.8 / 1.7 (220/ 230/ 240 V)
2.4 / 2.3 / 2.2 (220/ 230/ 240 V)
2.4 / 2.3 / 2.2 (220/ 230/ 240 V)
5.71
Running
current
Inrush current
Operation
data (1)
Cooling
COP
Heating
5.56
Sound level
Power level
Sound level
Power level
dB(A)
dB
Hi : 39 Me : 30 Lo : 21
47
Cooling
Heating
53
Hi : 38 Me : 33 Lo : 25
54
60
Noise
level
dB(A)
dB
47
59
Exterior dimensions (Height x Width x Depth)
mm
309 x 890 x 220
595 x 780 (+62) x 290
Exterior appearance
(Munsell color)
Fine snow
( 8.0Y 9.3/0.1 ) near equivalent
Stucco white
( 4.2Y 7.5/1.1 ) near equivalent
Net weight
kg
kW
kg
15
—
—
38
Compressor type & Q'ty
Motor (Starting method)
RM-B5077MDE1 (Rotary type) x 1
0.75 (Line starting)
Refrigerant oil
0.35 (DIAMOND FREEZE MA68)
R410A 1.2 (Pre-Charged up to the piping length of 15m)
Louver fins & inner grooved tubing M fins & inner grooved tubing
Refrigerant
equipment
Refrigerant (4)
Heat exchanger
Refrigerant control
Deice control
Fan type & Q'ty
Motor
Capillary tubes + Electronic expansion valve
Microcomputer control
Tangential fan x 1
27
Propeller fan x 1
24
Cooling
Heating
Hi : 11.5 Me : 8.0 Lo : 5.0
Hi : 12.0 Me : 9.5 Lo : 7.0
Not possible
29.5
Air handling
equipment
Air flow
CMM
27.0
Fresh air intake
—
Air filter, Quality / Quantity
Polypropylene net (washable) x 2
—
—
Shock & vibration absorber
Electric heater
Cushion rubber (for compressor)
—
—
—
—
Operation switch
Wireless-Remote control
Microcomputer thermostat
Operation
control
Room temperature control
RUN : Green, TIMER : Yellow, HI POWER : Green,
Operation Display
3D AUTO : Green, ECONO : Blue
Compressor overheat protection, Overcurrent protection,
Safety devices
Frost protection, Serial signal error protection, Indoor fan motor error protection,
Heating overload protection (High pressure control), Cooling overload protection
Refrigerant piping size (O.D)
Connecting method
mm
m
Liquid line : 6.35 (1/4") Gas line : 9.52 (3/8")
φ
φ
Flare connecting
Liquid line : 0.55
Gas line : 0.49
Attached length of piping
—
—
Installation
data
Insulation for piping
Necessary (Both sides), independent
Max. 15
Refrigerant line (one way) length
m
A
Vertical height difference between
outdoor unit and indoor unit
Max. 10 (Outdoor unit is higher)
Max. 10 (Outdoor unit is lower)
Drain hose
Connectable (VP16)
Power cable
—
Recommended breaker size
16
Size x Core number
Connecting method
1.5mm2 x 4 cores (Including earth cable)
Terminal block (Screw fixing type)
Connection wiring
Accessories (included)
Optional parts
Mounting kit, Clean filter (Allergen clear filter x 1, Photocatalytic washable deodorizing filter x 1)
Interface kit (SC-BIKN-E)
The pipe length is 7.5m.
Note (1) The data are measured at the following conditions.
Item
Indoor air temperature
Outdoor air temperature
Standards
DB
WB
19˚C
—
DB
35˚C
7˚C
WB
24˚C
6˚C
Operation
Cooling
Heating
27˚C
20˚C
ISO-T1, JIS C 9612
(2) This air-conditioner is manufactured and tested in conformity with the ISO.
(3) The operation data are applied to the 220/230/240V districts respectively.
(4) The refrigerant quantity to be charged includes the refrigerant in 15m connecting piping.
(Purging is not required even for the short piping.)
RWA000Z229
B
ꢂ
'10 • SR-T-091D
Adapted to RoHS directive
SRK25ZJX-S
Model
Item
Indoor unit SRK25ZJX-S
2550 (900 (Min.)
3130 (900 (Min.)
1 Phase, 220
0.49 (0.19
0.595 (0.23
Outdoor unit SRC25ZJX-S
Cooling capacity (1)
Heating capacity (1)
Power supply
W
W
~
~
~
~
3200 (Max.))
4700 (Max.))
240 V, 50Hz
0.82)
1.12)
Cooling
Heating
Cooling
Heating
Power
consumption
kW
A
~
2.5 / 2.4 / 2.3 (220/ 230/ 240 V)
3.1 / 2.9 / 2.8 (220/ 230/ 240 V)
3.1 / 2.9 / 2.8 (220/ 230/ 240 V)
5.20
Running
current
Inrush current
Operation
data (1)
Cooling
COP
Heating
5.26
Sound level
Power level
Sound level
Power level
dB(A)
dB
Hi : 41 Me : 31 Lo : 22
47
Cooling
Heating
55
Hi : 41 Me : 34 Lo : 27
58
60
Noise
level
dB(A)
dB
47
60
Exterior dimensions (Height x Width x Depth)
mm
309 x 890 x 220
595 x 780 (+62) x 290
Exterior appearance
(Munsell color)
Fine snow
( 8.0Y 9.3/0.1 ) near equivalent
Stucco white
( 4.2Y 7.5/1.1 ) near equivalent
Net weight
kg
kW
kg
15
—
—
38
Compressor type & Q'ty
Motor (Starting method)
RM-B5077MDE1 (Rotary type) x 1
0.75 (Line starting)
Refrigerant oil
0.35 (DIAMOND FREEZE MA68)
R410A 1.2 (Pre-Charged up to the piping length of 15m)
Louver fins & inner grooved tubing M fins & inner grooved tubing
Refrigerant
equipment
Refrigerant (4)
Heat exchanger
Refrigerant control
Deice control
Fan type & Q'ty
Motor
Capillary tubes + Electronic expansion valve
Microcomputer control
Tangential fan x 1
27
Propeller fan x 1
24
W
Cooling
Heating
Hi : 12.5 Me : 9.0 Lo : 5.0
Hi : 13.0 Me : 10.0 Lo : 7.5
Not possible
29.5
Air handling
equipment
Air flow
CMM
27.0
Fresh air intake
—
Air filter, Quality / Quantity
Polypropylene net (washable) x 2
—
—
Shock & vibration absorber
Electric heater
Cushion rubber (for compressor)
—
—
—
—
Operation switch
Wireless-Remote control
Microcomputer thermostat
Operation
control
Room temperature control
RUN : Green, TIMER : Yellow, HI POWER : Green,
Operation Display
3D AUTO : Green, ECONO : Blue
Compressor overheat protection, Overcurrent protection,
Safety devices
Frost protection, Serial signal error protection, Indoor fan motor error protection,
Heating overload protection (High pressure control), Cooling overload protection
Refrigerant piping size (O.D)
Connecting method
mm
m
Liquid line : 6.35 (1/4") Gas line : 9.52 (3/8")
φ
φ
Flare connecting
Liquid line : 0.55
Gas line : 0.49
Attached length of piping
—
—
Installation
data
Insulation for piping
Necessary (Both sides), independent
Max. 15
Refrigerant line (one way) length
m
A
Vertical height difference between
outdoor unit and indoor unit
Max. 10 (Outdoor unit is higher)
Max. 10 (Outdoor unit is lower)
Drain hose
Connectable (VP16)
Power cable
—
Recommended breaker size
16
Size x Core number
Connecting method
1.5mm2 x 4 cores (Including earth cable)
Terminal block (Screw fixing type)
Connection wiring
Accessories (included)
Optional parts
Mounting kit, Clean filter (Allergen clear filter x 1, Photocatalytic washable deodorizing filter x 1)
Interface kit (SC-BIKN-E)
The pipe length is 7.5m.
Note (1) The data are measured at the following conditions.
Item
Indoor air temperature
Outdoor air temperature
Standards
DB
WB
19˚C
—
DB
35˚C
7˚C
WB
24˚C
6˚C
Operation
Cooling
Heating
27˚C
20˚C
ISO-T1, JIS C 9612
(2) This air-conditioner is manufactured and tested in conformity with the ISO.
(3) The operation data are applied to the 220/230/240V districts respectively.
(4) The refrigerant quantity to be charged includes the refrigerant in 15m connecting piping.
(Purging is not required even for the short piping.)
RWA000Z229
B
ꢃ
'10 • SR-T-091D
Adapted to RoHS directive
SRK35ZJX-S
Model
Item
Indoor unit SRK35ZJX-S
3500 (900 (Min.)
4300 (900 (Min.)
1 Phase, 220
Outdoor unit SRC35ZJX-S
Cooling capacity (1)
Heating capacity (1)
Power supply
W
W
~
~
~
4100 (Max.))
5100 (Max.))
240 V, 50Hz
Cooling
Heating
Cooling
Heating
0.845 (0.19
~
1.35)
1.01)
Power
consumption
kW
A
0.960 (0.23
~
4.0 / 3.8 / 3.6 (220/ 230/ 240 V)
4.6 / 4.4 / 4.2 (220/ 230/ 240 V)
4.6 / 4.4 / 4.2 (220/ 230/ 240 V)
4.14
Running
current
Inrush current
Operation
data (1)
Cooling
COP
Heating
4.48
Sound level
Power level
Sound level
Power level
dB(A)
dB
Hi : 43 Me : 33 Lo : 22
50
Cooling
Heating
58
Hi : 42 Me : 35 Lo : 27
59
63
Noise
level
dB(A)
dB
50
62
Exterior dimensions (Height x Width x Depth)
mm
309 x 890 x 220
595 x 780 (+62) x 290
Exterior appearance
(Munsell color)
Fine snow
( 8.0Y 9.3/0.1 ) near equivalent
Stucco white
( 4.2Y 7.5/1.1 ) near equivalent
Net weight
kg
kW
kg
15
—
—
38
Compressor type & Q'ty
Motor (Starting method)
RM-B5077MDE1 (Rotary type) x 1
0.90 (Line starting)
Refrigerant oil
0.35 (DIAMOND FREEZE MA68)
R410A 1.2 (Pre-Charged up to the piping length of 15m)
Louver fins & inner grooved tubing M fins & inner grooved tubing
Refrigerant
equipment
Refrigerant (4)
Heat exchanger
Refrigerant control
Deice control
Fan type & Q'ty
Motor
Capillary tubes + Electronic expansion valve
Microcomputer control
Tangential fan x 1
27
Propeller fan x 1
24
W
Cooling
Heating
Hi : 13.5 Me : 9.5 Lo : 5.0
Hi : 14.0 Me : 11.0 Lo : 8.0
Not possible
32.5
Air handling
equipment
Air flow
CMM
29.5
Fresh air intake
—
Air filter, Quality / Quantity
Polypropylene net (washable) x 2
—
—
Shock & vibration absorber
Electric heater
Cushion rubber (for compressor)
—
—
—
—
Operation switch
Wireless-Remote control
Microcomputer thermostat
Operation
control
Room temperature control
RUN : Green, TIMER : Yellow, HI POWER : Green,
Operation Display
3D AUTO : Green, ECONO : Blue
Compressor overheat protection, Overcurrent protection,
Safety devices
Frost protection, Serial signal error protection, Indoor fan motor error protection,
Heating overload protection (High pressure control), Cooling overload protection
Refrigerant piping size (O.D)
Connecting method
mm
m
Liquid line : 6.35 (1/4") Gas line : 9.52 (3/8")
φ
φ
Flare connecting
Liquid line : 0.55
Gas line : 0.49
Attached length of piping
—
—
Installation
data
Insulation for piping
Necessary (Both sides), independent
Max. 15
Refrigerant line (one way) length
m
A
Vertical height difference between
outdoor unit and indoor unit
Max. 10 (Outdoor unit is higher)
Max. 10 (Outdoor unit is lower)
Drain hose
Connectable (VP16)
Power cable
—
Recommended breaker size
16
Size x Core number
Connecting method
1.5mm2 x 4 cores (Including earth cable)
Terminal block (Screw fixing type)
Connection wiring
Accessories (included)
Optional parts
Mounting kit, Clean filter (Allergen clear filter x 1, Photocatalytic washable deodorizing filter x 1)
Interface kit (SC-BIKN-E)
The pipe length is 7.5m.
Note (1) The data are measured at the following conditions.
Item
Indoor air temperature
Outdoor air temperature
Standards
DB
WB
19˚C
—
DB
35˚C
7˚C
WB
24˚C
6˚C
Operation
Cooling
Heating
27˚C
20˚C
ISO-T1, JIS C 9612
(2) This air-conditioner is manufactured and tested in conformity with the ISO.
(3) The operation data are applied to the 220/230/240V districts respectively.
(4) The refrigerant quantity to be charged includes the refrigerant in 15m connecting piping.
(Purging is not required even for the short piping.)
RWA000Z229
B
ꢄ
'10 • SR-T-091D
Adapted to RoHS directive
SRK50ZJX-S
Model
Item
Indoor unit SRK50ZJX-S
5000 (700 (Min.)
6000 (700 (Min.)
1 Phase, 220
Outdoor unit SRC50ZIX-S
Cooling capacity (1)
Heating capacity (1)
Power supply
W
W
~
~
~
6200 (Max.))
8800 (Max.))
240 V, 50Hz
Cooling
Heating
Cooling
Heating
1.30 (0.2
~
2.26)
2.20)
Power
consumption
kW
A
1.35 (0.2~
6.0 / 5.7 / 5.5 (220/ 230/ 240 V)
6.2 / 5.9 / 5.7 (220/ 230/ 240 V)
6.2 / 5.9 / 5.7 (220/ 230/ 240 V)
3.85
Running
current
Inrush current
Operation
data (1)
Cooling
COP
Heating
4.44
Sound level
Power level
Sound level
Power level
dB(A)
dB
Hi : 45 Me : 38 Lo : 26
48
Cooling
Heating
60
Hi : 45 Me : 38 Lo : 32
62
62
Noise
level
dB(A)
dB
48
62
Exterior dimensions (Height x Width x Depth)
mm
309 x 890 x 220
640 x 800 (+71) x 290
Exterior appearance
(Munsell color)
Fine snow
( 8.0Y 9.3/0.1 ) near equivalent
Stucco white
( 4.2Y 7.5/1.1 ) near equivalent
Net weight
kg
kW
kg
15
—
—
43
Compressor type & Q'ty
Motor (Starting method)
5CS130XGB04 (Scroll type) x 1
0.9 (Line starting)
Refrigerant oil
0.48 (RB68A or Freol Alpha 68M)
R410A 1.4 (Pre-Charged up to the piping length of 15m)
Louver fins & inner grooved tubing M fins & inner grooved tubing
Refrigerant
equipment
Refrigerant (3)
Heat exchanger
Refrigerant control
Deice control
Fan type & Q'ty
Motor
Capillary tubes + Electronic expansion valve
Microcomputer control
Tangential fan x 1
27
Propeller fan x 1
34
W
Cooling
Heating
Hi : 13.5 Me : 11 Lo: 8
Hi : 16.5 Me : 14.5 Lo : 10.5
Not possible
36.0
Air handling
equipment
Air flow
CMM
33.0
Fresh air intake
—
Air filter, Quality / Quantity
Polypropylene net (washable) x 2
—
—
Shock & vibration absorber
Electric heater
Cushion rubber (for compressor)
—
—
—
—
Operation switch
Wireless-Remote control
Microcomputer thermostat
Operation
control
Room temperature control
RUN : Green, TIMER : Yellow, HI POWER : Green,
Operation Display
3D AUTO : Green, ECONO : Blue
Compressor overheat protection, Overcurrent protection,
Safety devices
Frost protection, Serial signal error protection, Indoor fan motor error protection,
Heating overload protection (High pressure control), Cooling overload protection
Refrigerant piping size (O.D)
Connecting method
mm
m
Liquid line : 6.35 (1/4") Gas line : 12.7 (1/2")
φ
φ
Flare connecting
Liquid line : 0.55
Gas line : 0.49
Attached length of piping
—
—
Installation
data
Insulation for piping
Necessary (Both sides), independent
Max. 30
Refrigerant line (one way) length
m
A
Vertical height difference between
outdoor unit and indoor unit
Max. 20 (Outdoor unit is higher)
Max. 20 (Outdoor unit is lower)
Drain hose
Connectable (VP16)
Power cable
—
Recommended breaker size
16
Size x Core number
Connecting method
1.5mm2 x 4 cores (Including earth cable)
Terminal block (Screw fixing type)
Connection wiring
Accessories (included)
Optional parts
Mounting kit, Clean filter (Allergen clear filter x 1, Photocatalytic washable deodorizing filter x 1)
Interface kit (SC-BIKN-E)
The pipe length is 7.5m.
Note (1) The data are measured at the following conditions.
Item
Indoor air temperature
Outdoor air temperature
Standards
DB
WB
19˚C
—
DB
35˚C
7˚C
WB
24˚C
6˚C
Operation
Cooling
Heating
27˚C
20˚C
ISO-T1, JIS C 9612
(2) This air-conditioner is manufactured and tested in conformity with the ISO.
(3) The operation data are applied to the 220/230/240V districts respectively.
(4) The refrigerant quantity to be charged includes the refrigerant in 15m connecting piping.
(Purging is not required even for the short piping.)
RWA000Z229
B
ꢅ
'10 • SR-T-091D
Adapted to RoHS directive
SRK60ZJX-S
Model
Item
Indoor unit SRK60ZJX-S
6000 (800 (Min.)
6800 (800 (Min.)
1 Phase, 220
Outdoor unit SRC60ZIX-S
Cooling capacity (1)
Heating capacity (1)
Power supply
W
W
~
~
~
6800 (Max.))
9700 (Max.))
240 V, 50Hz
Cooling
Heating
Cooling
Heating
1.86 (0.25
~
2.70)
2.30)
Power
consumption
kW
A
1.67 (0.25~
8.5 / 8.2 / 7.8 (220/ 230/ 240 V)
7.7 / 7.3 / 7.0 (220/ 230/ 240 V)
8.5 / 8.2 / 7.8 (220/ 230/ 240 V)
3.23
Running
current
Inrush current
Operation
data (1)
Cooling
COP
Heating
4.07
Sound level
Power level
Sound level
Power level
dB(A)
dB
Hi : 47 Me : 38 Lo : 26
51
Cooling
Heating
62
Hi : 45 Me : 39 Lo : 33
62
65
Noise
level
dB(A)
dB
51
65
Exterior dimensions (Height x Width x Depth)
mm
309 x 890 x 220
640 x 800 (+71) x 290
Exterior appearance
(Munsell color)
Fine snow
( 8.0Y 9.3/0.1 ) near equivalent
Stucco white
( 4.2Y 7.5/1.1 ) near equivalent
Net weight
kg
kW
kg
15
—
—
43
Compressor type & Q'ty
Motor (Starting method)
5CS130XGB04 (Scroll type) x 1
0.9 (Line starting)
Refrigerant oil
0.48 (RB68A or Freol Alpha 68M)
R410A 1.4 (Pre-Charged up to the piping length of 15m)
Louver fins & inner grooved tubing M fins & inner grooved tubing
Refrigerant
equipment
Refrigerant (3)
Heat exchanger
Refrigerant control
Deice control
Fan type & Q'ty
Motor
Capillary tubes + Electronic expansion valve
Microcomputer control
Tangential fan x 1
27
Propeller fan x 1
34
W
Cooling
Heating
Hi : 14.5 Me : 12.5 Lo : 8.5
Hi : 17.0 Me : 15.0 Lo : 11.0
Not possible
41.5
Air handling
equipment
Air flow
CMM
36.0
Fresh air intake
—
Air filter, Quality / Quantity
Polypropylene net (washable) x 2
—
—
Shock & vibration absorber
Electric heater
Cushion rubber (for compressor)
—
—
—
—
Operation switch
Wireless-Remote control
Microcomputer thermostat
Operation
control
Room temperature control
RUN : Green, TIMER : Yellow, HI POWER : Green,
Operation Display
3D AUTO : Green, ECONO : Blue
Compressor overheat protection, Overcurrent protection,
Safety devices
Frost protection, Serial signal error protection, Indoor fan motor error protection,
Heating overload protection (High pressure control), Cooling overload protection
Refrigerant piping size (O.D)
Connecting method
mm
m
Liquid line : 6.35 (1/4") Gas line : 12.7 (1/2")
φ
φ
Flare connecting
Liquid line : 0.55
Gas line : 0.49
Attached length of piping
—
—
Installation
data
Insulation for piping
Necessary (Both sides), independent
Max. 30
Refrigerant line (one way) length
m
A
Vertical height difference between
outdoor unit and indoor unit
Max. 20 (Outdoor unit is higher)
Max.20 (Outdoor unit is lower)
Drain hose
Connectable (VP 16)
Power cable
—
Recommended breaker size
16
Size x Core number
Connecting method
1.5mm2 x 4 cores (Including earth cable)
Terminal block (Screw fixing type)
Connection wiring
Accessories (included)
Optional parts
Mounting kit, Clean filter (Allergen clear filter x 1, Photocatalytic washable deodorizing filter x 1)
Interface kit (SC-BIKN-E)
The pipe length is 7.5m.
Note (1) The data are measured at the following conditions.
Item
Indoor air temperature
Outdoor air temperature
Standards
DB
WB
19˚C
—
DB
35˚C
7˚C
WB
24˚C
6˚C
Operation
Cooling
Heating
27˚C
20˚C
ISO-T1, JIS C 9612
(2) This air-conditioner is manufactured and tested in conformity with the ISO.
(3) The operation data are applied to the 220/230/240V districts respectively.
(4) The refrigerant quantity to be charged includes the refrigerant in 15m connecting piping.
(Purging is not required even for the short piping.)
RWA000Z229
B
ꢆ
'10 • SR-T-091D
(2) Floor standing type (SRF)
Adapted to RoHS directive
SRF25ZJX-S
Model
Item
Indoor unit SRF25ZJX-S
2500 (900 (Min.)
3400 (900 (Min.)
1 Phase, 220
Outdoor unit SRC25ZJX-S
Cooling capacity (1)
Heating capacity (1)
Power supply
W
W
~
~
~
3200 (Max.))
4700 (Max.))
240 V, 50Hz
Cooling
Heating
Cooling
Heating
0.521 (0.19
~
1.20)
0.82)
Power
consumption
kW
A
0.723 (0.23
~
2.6 / 2.5 / 2.4 (220/ 230/ 240 V)
3.6 / 3.4 / 3.3 (220/ 230/ 240 V)
3.6 / 3.4 / 3.3 (220/ 230/ 240 V)
4.80
Running
current
Inrush current
Operation
data (1)
Cooling
COP
Heating
4.70
Sound level
Power level
Sound level
Power level
dB(A)
dB
Hi : 40 Me : 32 Lo : 26
47
Cooling
Heating
51
Hi : 40 Me : 35 Lo : 28
51
60
Noise
level
dB(A)
dB
47
60
Exterior dimensions (Height x Width x Depth)
mm
600 x 860 x 238
595 x 780 x 290
Exterior appearance
( Munsell color )
Fine snow
( 8.0Y 9.3/0.1 ) near equivalent
Stucco white
( 4.2Y 7.5/1.1 ) near equivalent
Net weight
kg
kW
kg
18
—
—
38
Compressor type & Q'ty
Motor (Starting method)
RM-B5077MDE1 (Rotary type) x 1
0.75 (Line starting)
Refrigerant oil
0.35 (DIAMOND FREEZE MA68)
R410A 1.2 (Pre-Charged up to the piping length of 15m)
Louver fins & inner grooved tubing M fins & inner grooved tubing
Refrigerant
equipment
Refrigerant (3)
Heat exchanger
Refrigerant control
Deice control
Fan type & Q'ty
Motor
Capillary tubes + Electronic expansion valve
Microcomputer control
Turbo fan x 1
40
Propeller fan x 1
24
W
Cooling
Heating
Hi : 9.0 Me : 7.6 Lo : 5.8
Hi : 10.5 Me : 8.2 Lo : 6.6
Impossible
29.5
Air handling
equipment
Air flow
CMM
27.0
Fresh air intake
—
Air filter, Quality / Quantity
Polypropylene net (washable) x 1
—
—
Shock & vibration absorber
Electric heater
Cushion rubber (for compressor)
—
—
—
—
Operation switch
Wireless-Remote control
Microcomputer thermostat
Operation
control
Room temperature control
RUN : Green, TIMER : Yellow, HI POWER : Green,
AIR OUTLET SELECTION : Green, ECONO : Green
Operation Display
Compressor overheat protection, Overcurrent protection,
Safety devices
Frost protection, Serial signal error protection, Indoor fan motor error protection,
Heating overload protection (High pressure control), Cooling overload protection
Refrigerant piping size (O.D)
Connecting method
mm
m
Liquid line : 6.35 (1/4") Gas line : 9.52 (3/8")
φ
φ
Flare connecting
Attached length of piping
—
—
—
Installation
data
Insulation for piping
Necessary (Both sides), independent
Max. 15
Refrigerant line (one way) length
m
A
Vertical height difference between
outdoor unit and indoor unit
Max. 10 (Outdoor unit is higher)
Max. 10 (Outdoor unit is lower)
Drain hose
Connectable (VP16)
Power cable
—
Recommended breaker size
16
Size x Core number
Connecting method
1.5mm2 x 4 cores (Including earth cable)
Terminal block (Screw fixing type)
Connection wiring
Accessories (included)
Optional parts
Mounting kit, Clean filter (Natural enzyme filter x 1, Photocatalytic washable deodorizing filter x 1)
Interface kit (SC-BIKN-E)
The pipe length is 7.5m.
Note (1) The data are measured at the following conditions.
Item
Indoor air temperature
Outdoor air temperature
Standards
DB
WB
19˚C
—
DB
35˚C
7˚C
WB
24˚C
6˚C
Operation
Cooling
Heating
27˚C
20˚C
ISO-T1, JIS C 9612
(2) This air-conditioner is manufactured and tested in conformity with the ISO.
(3) The operation data are applied to the 220/230/240V districts respectively.
(4) The refrigerant quantity to be charged includes the refrigerant in 15m connecting piping.
(Purging is not required even for the short piping.)
RWB000Z053
A
ꢇ
'10 • SR-T-091D
Adapted to RoHS directive
SRF35ZJX-S
Model
Item
Indoor unit SRF35ZJX-S
3500 (900 (Min.)
4500 (900 (Min.)
1 Phase, 220
Outdoor unit SRC35ZJX-S
Cooling capacity (1)
Heating capacity (1)
Power supply
W
W
~
~
~
4100 (Max.))
5100 (Max.))
240 V, 50Hz
Cooling
Heating
Cooling
Heating
0.890 (0.19
~
1.43)
1.26)
Power
consumption
kW
A
1.124 (0.23
~
4.1 / 3.9 / 3.7 (220/ 230/ 240 V)
5.2 / 4.9 / 4.7 (220/ 230/ 240 V)
5.2 / 4.9 / 4.7 (220/ 230/ 240 V)
3.93
Running
current
Inrush current
Operation
data (1)
Cooling
COP
Heating
4.00
Sound level
Power level
Sound level
Power level
dB(A)
dB
Hi : 41 Me : 34 Lo : 28
50
Cooling
Heating
52
Hi : 41 Me : 36 Lo : 31
52
63
Noise
level
dB(A)
dB
50
62
Exterior dimensions (Height x Width x Depth)
mm
600 x 860 x 238
595 x 780 x 290
Exterior appearance
( Munsell color )
Fine snow
( 8.0Y 9.3/0.1 ) near equivalent
Stucco white
( 4.2Y 7.5/1.1 ) near equivalent
Net weight
kg
kW
kg
19
—
—
38
Compressor type & Q'ty
Motor (Starting method)
RM-B5077MDE1 (Rotary type) x 1
0.90 (Line starting)
Refrigerant oil
0.35 (DIAMOND FREEZE MA68)
R410A 1.2 (Pre-Charged up to the piping length of 15m)
Louver fins & inner grooved tubing M fins & inner grooved tubing
Refrigerant
equipment
Refrigerant (3)
Heat exchanger
Refrigerant control
Deice control
Fan type & Q'ty
Motor
Capillary tubes + Electronic expansion valve
Microcomputer control
Turbo fan x 1
40
Propeller fan x 1
24
W
Cooling
Heating
Hi : 9.2 Me : 7.8 Lo : 6.4
Hi : 10.7 Me : 8.3 Lo : 7.4
Impossible
32.5
Air handling
equipment
Air flow
CMM
29.5
Fresh air intake
—
Air filter, Quality / Quantity
Polypropylene net (washable) x 1
—
—
Shock & vibration absorber
Electric heater
Cushion rubber (for compressor)
—
—
—
—
Operation switch
Wireless-Remote control
Microcomputer thermostat
Operation
control
Room temperature control
RUN : Green, TIMER : Yellow, HI POWER : Green,
AIR OUTLET SELECTION : Green, ECONO : Green
Operation Display
Compressor overheat protection, Overcurrent protection,
Safety devices
Frost protection, Serial signal error protection, Indoor fan motor error protection,
Heating overload protection (High pressure control), Cooling overload protection
Refrigerant piping size (O.D)
Connecting method
mm
m
Liquid line : 6.35 (1/4") Gas line : 9.52 (3/8")
φ
φ
Flare connecting
Attached length of piping
—
—
—
Installation
data
Insulation for piping
Necessary (Both sides), independent
Max. 15
Refrigerant line (one way) length
m
A
Vertical height difference between
outdoor unit and indoor unit
Max. 10 (Outdoor unit is higher)
Max.10 (Outdoor unit is lower)
Drain hose
Connectable (VP16)
Power cable
—
Recommended breaker size
16
Size x Core number
Connecting method
1.5mm2 x 4 cores (Including earth cable)
Terminal block (Screw fixing type)
Connection wiring
Accessories (included)
Optional parts
Mounting kit, Clean filter (Natural enzyme filter x 1, Photocatalytic washable deodorizing filter x 1)
Interface kit (SC-BIKN-E)
The pipe length is 7.5m.
Note (1) The data are measured at the following conditions.
Item
Indoor air temperature
Outdoor air temperature
Standards
DB
WB
19˚C
—
DB
35˚C
7˚C
WB
24˚C
6˚C
Operation
Cooling
Heating
27˚C
20˚C
ISO-T1, JIS C 9612
(2) This air-conditioner is manufactured and tested in conformity with the ISO.
(3) The operation data are applied to the 220/230/240V districts respectively.
(4) The refrigerant quantity to be charged includes the refrigerant in 15m connecting piping.
(Purging is not required even for the short piping.)
RWB000Z053
A
ꢈ
'10 • SR-T-091D
Adapted to RoHS directive
SRF50ZJX-S
Model
Item
Indoor unit SRF50ZJX-S
5000 (700 (Min.)
6000 (700 (Min.)
1 Phase, 220
Outdoor unit SRC50ZIX-S
Cooling capacity (1)
Heating capacity (1)
Power supply
W
W
~
~
~
5500 (Max.))
7000 (Max.))
240 V, 50Hz
Cooling
Heating
Cooling
Heating
1.390 (0.2
~
2.25)
1.80)
Power
consumption
kW
A
1.540 (0.2~
6.4 / 6.1 / 5.8 (220/ 230/ 240 V)
7.1 / 6.8 / 6.5 (220/ 230/ 240 V)
7.1 / 6.8 / 6.5 (220/ 230/ 240 V)
3.60
Running
current
Inrush current
Operation
data (1)
Cooling
COP
Heating
3.90
Sound level
Power level
Sound level
Power level
dB(A)
dB
Hi : 47 Me : 39 Lo : 30
48
Cooling
Heating
58
Hi : 47 Me : 39 Lo : 32
58
62
Noise
level
dB(A)
dB
48
62
Exterior dimensions (Height x Width x Depth)
mm
600 x 860 x 238
640 x 800 x 290
Exterior appearance
(Munsell color)
Fine snow
( 8.0Y 9.3/0.1 ) near equivalent
Stucco white
( 4.2Y 7.5/1.1 ) near equivalent
Net weight
kg
kW
kg
19
—
—
43
Compressor type & Q'ty
Motor (Starting method)
5CS130XGB04 (Scroll type) x 1
0.9 (Line starting)
Refrigerant oil
0.48 (RB68A or Freol Alpha 68M)
R410A 1.4 (Pre-Charged up to the piping length of 15m)
Louver fins & inner grooved tubing M fins & inner grooved tubing
Refrigerant
equipment
Refrigerant (3)
Heat exchanger
Refrigerant control
Deice control
Fan type & Q'ty
Motor
Capillary tubes + Electronic expansion valve
Microcomputer control
Turbo fan x 1
40
Propeller fan x 1
34
W
Cooling
Heating
Hi : 11.5 Me : 9.6 Lo : 6.6
Hi : 12.0 Me : 10.0 Lo : 7.6
Impossible
36.0
Air handling
equipment
Air flow
CMM
33.0
Fresh air intake
—
Air filter, Quality / Quantity
Polypropylene net (washable) x 1
—
—
Shock & vibration absorber
Electric heater
Cushion rubber (for compressor)
—
—
—
—
Operation switch
Wireless-Remote control
Microcomputer thermostat
Operation
control
Room temperature control
RUN : Green, TIMER : Yellow, HI POWER : Green,
AIR OUTLET SELECTION : Green, ECONO : Green
Operation Display
Compressor overheat protection, Overcurrent protection,
Safety devices
Frost protection, Serial signal error protection, Indoor fan motor error protection,
Heating overload protection (High pressure control), Cooling overload protection
Refrigerant piping size (O.D)
Connecting method
mm
m
Liquid line : 6.35 (1/4") Gas line : 12.7 (1/2")
φ
φ
Flare connecting
Attached length of piping
—
—
—
Installation
data
Insulation for piping
Necessary (Both sides), independent
Max. 30
Refrigerant line (one way) length
m
A
Vertical height difference between
outdoor unit and indoor unit
Max. 20 (Outdoor unit is higher)
Max. 20 (Outdoor unit is lower)
Drain hose
Connectable (VP16)
Power cable
—
Recommended breaker size
16
Size x Core number
Connecting method
1.5mm2 x 4 cores (Including earth cable)
Terminal block (Screw fixing type)
Connection wiring
Accessories (included)
Optional parts
Mounting kit, Clean filter (Natural enzyme filter x 1, Photocatalytic washable deodorizing filter x 1)
Interface kit (SC-BIKN-E)
The pipe length is 7.5m.
Note (1) The data are measured at the following conditions.
Item
Indoor air temperature
Outdoor air temperature
Standards
DB
WB
19˚C
—
DB
35˚C
7˚C
WB
24˚C
6˚C
Operation
Cooling
Heating
27˚C
20˚C
ISO-T1, JIS C 9612
(2) This air-conditioner is manufactured and tested in conformity with the ISO.
(3) The operation data are applied to the 220/230/240V districts respectively.
(4) The refrigerant quantity to be charged includes the refrigerant in 15m connecting piping.
(Purging is not required even for the short piping.)
RWB000Z053
A
ꢀ0
'10 • SR-T-091D
(3) Ceiling concealed type (SRR)
Adapted to RoHS directive
SRR25ZJ-S
Model
Item
Indoor unit SRR25ZJ-S
2500 ( 900 (Min.)
3400 ( 900 (Min.)
1 Phase, 220
Outdoor unit SRC25ZJX-S
Cooling capacity (1)
Heating capacity (1)
Power supply
W
W
~
~
~
3200 (Max.))
4700 (Max.))
240 V, 50Hz
Cooling
Heating
Cooling
Heating
0.580 ( 0.19
~
1.20 )
0.82 )
Power
consumption
kW
A
0.750 ( 0.23
~
2.9 / 2.8 / 2.7 (220/ 230/ 240 V)
3.7 / 3.6 / 3.4 (220/ 230/ 240 V)
3.7 / 3.6 / 3.4 (220/ 230/ 240 V)
4.31
Running
current
Inrush current
Operation
data (1)
Cooling
COP
Heating
4.53
Sound level
Power level
Sound level
Power level
dB(A)
dB
Hi : 40 Me : 35 Lo : 29
47
Cooling
Heating
54
Hi: 41 Me: 38 Lo: 31
55
60
Noise
level
dB(A)
dB
47
60
Exterior dimensions (Height x Width x Depth)
mm
230 x 740 x 455
595 x 780 x 290
Exterior appearance
(Munsell color)
Stucco white
( 4.2Y 7.5/1.1 ) near equivalent
—
Net weight
kg
kW
kg
22
—
—
38
Compressor type & Q'ty
Motor (Starting method)
RM-B5077MDE1 (Rotary type) x 1
0.75 (Line starting)
Refrigerant oil
0.35 (DIAMOND FREEZE MA68)
R410A 1.2 ( Pre-Charged up to the piping length of 15m )
Louver fins & inner grooved tubing M fins & inner grooved tubing
Refrigerant
equipment
Refrigerant (3)
Heat exchanger
Refrigerant control
Deice control
Fan type & Q'ty
Motor
Capillary tubes + Electronic expansion valve
Microcomputer control
Centrifugal fan x 2
51
Propeller fan x 1
24
W
Cooling
Heating
Hi : 8.5 Me : 7.0 Lo : 5.0
Hi : 10.0 Me : 9.0 Lo : 6.5
Not possible
29.5
Air handling
equipment
Air flow
CMM
27.0
Fresh air intake
—
Air filter, Quality / Quantity
Polypropylene net x 1
—
—
Shock & vibration absorber
Electric heater
Cushion rubber (for compressor)
—
—
—
—
Operation switch
Wireless-Remote control
Microcomputer thermostat
Operation
control
Room temperature control
RUN : Green, TIMER : Yellow,
HI POWER : Green, ECONO : Green
Operation Display
Compressor overheat protection, Overcurrent protection, Drain error protection
Frost protection, Serial signal error protection, Indoor fan motor error protection,
Heating overload protection( High pressure control ), Cooling overload protection
Safety devices
Refrigerant piping size (O.D)
Connecting method
mm
m
Liquid line : 6.35 (1/4") Gas line : 9.52 (3/8")
φ
φ
Flare connecting
Attached length of piping
—
—
Installation
data
Insulation for piping
Necessary (Both sides), independent
Max. 15
Refrigerant line (one way) length
m
A
Vertical height difference between
outdoor unit and indoor unit
Max. 10 (Outdoor unit is higher)
Max. 10 (Outdoor unit is lower)
Drain hose
Connectable (VP16)
—
Power cable
—
Recommended breaker size
16
Size x Core number
Connecting method
1.5mm2 x 4 cores (Including earth cable)
Terminal block (Screw fixing type)
Mounting kit
Connection wiring
Accessories (included)
Optional parts
Wired remote control, Interface kit (SC-BIKN-E)
The pipe length is 7.5m.
Note (1) The data are measured at the following conditions.
Item
Indoor air temperature
Outdoor air temperature
Standards
DB
WB
19˚C
—
DB
35˚C
7˚C
WB
24˚C
6˚C
Operation
Cooling
Heating
27˚C
20˚C
ISO-T1, JIS C 9612
(2) This air-conditioner is manufactured and tested in conformity with the ISO.
(3) The operation data are applied to the 220/230/240V districts respectively.
(4) The refrigerant quantity to be charged includes the refrigerant in 15m connecting piping.
(Purging is not required even for the short piping.)
RWA000Z231
A
ꢀꢀ
'10 • SR-T-091D
Adapted to RoHS directive
SRR35ZJ-S
Model
Item
Indoor unit SRR35ZJ-S
3500 ( 900 (Min.)
4200 ( 900 (Min.)
1 Phase, 220
Outdoor unit SRC35ZJX-S
Cooling capacity (1)
Heating capacity (1)
Power supply
W
W
~
~
~
4100 (Max.))
5100 (Max.))
240 V, 50Hz
Cooling
Heating
Cooling
Heating
1.080 ( 0.19
~
1.43 )
1.26 )
Power
consumption
kW
A
1.100 ( 0.23
~
5.0 / 4.7 / 4.5 (220/ 230/ 240 V)
5.1 / 4.8 / 4.6 (220/ 230/ 240 V)
5.1 / 4.8 / 4.6 (220/ 230/ 240 V)
3.24
Running
current
Inrush current
Operation
data (1)
Cooling
COP
Heating
3.82
Sound level
Power level
Sound level
Power level
dB(A)
dB
Hi: 42 Me : 37 Lo: 30
50
Cooling
Heating
56
Hi : 43 Me : 40 Lo : 32
57
62
Noise
level
dB(A)
dB
50
62
Exterior dimensions (Height x Width x Depth)
mm
230 x 740 x 455
595 x 780 x 290
Exterior appearance
(Munsell color)
Stucco white
(4.2Y 7.5/1.1) near equivalent
—
Net weight
kg
kW
kg
22
—
—
38
Compressor type & Q'ty
Motor (Starting method)
RM-B5077MDE1 (Rotary type) x 1
0.75 ( Line starting )
Refrigerant oil
0.35 (DIAMOND FREEZE MA68)
R410A 1.2 (Pre-Charged up to the piping length of 15m)
Louver fins & inner grooved tubing M fins & inner grooved tubing
Refrigerant
equipment
Refrigerant (3)
Heat exchanger
Refrigerant control
Deice control
Fan type & Q'ty
Motor
Capillary tubes + Electronic expansion valve
Microcomputer control
Centrifugal fan x 2
51
Propeller fan x 1
24
W
Cooling
Heating
Hi : 9.0 Me : 7.5 Lo : 5.5
Hi : 11.0 Me : 9.5 Lo : 7.0
Not possible
32.5
Air handling
equipment
Air flow
CMM
29.5
Fresh air intake
—
Air filter, Quality / Quantity
Polypropylene net x 1
—
—
Shock & vibration absorber
Electric heater
Cushion rubber (for compressor)
—
—
—
—
Operation switch
Wireless-Remote control
Microcomputer thermostat
Operation
control
Room temperature control
RUN : Green, TIMER : Yellow,
HI POWER : Green, ECONO : Green
Operation Display
Compressor overheat protection, Overcurrent protection, Drain error protection
Frost protection, Serial signal error protection, Indoor fan motor error protection,
Heating overload protection (High pressure control), Cooling overload protection
Safety devices
Refrigerant piping size (O.D)
Connecting method
mm
m
Liquid line : 6.35 (1/4") Gas line : 9.52 (3/8")
φ
φ
Flare connecting
Attached length of piping
—
—
Installation
data
Insulation for piping
Necessary (Both sides), independent
Max. 15
Refrigerant line (one way) length
m
A
Vertical height difference between
outdoor unit and indoor unit
Max. 10 (Outdoor unit is higher)
Max. 10 (Outdoor unit is lower)
Drain hose
Connectable (VP16)
—
Power cable
—
Recommended breaker size
16
Size x Core number
Connecting method
1.5mm2 x 4 cores (Including earth cable)
Terminal block (Screw fixing type)
Mounting kit
Connection wiring
Accessories (included)
Optional parts
Wired remote control, Interface kit (SC-BIKN-E)
The pipe length is 7.5m.
Note (1) The data are measured at the following conditions.
Item
Indoor air temperature
Outdoor air temperature
Standards
DB
WB
19˚C
—
DB
35˚C
7˚C
WB
24˚C
6˚C
Operation
Cooling
Heating
27˚C
20˚C
ISO-T1, JIS C 9612
(2) This air-conditioner is manufactured and tested in conformity with the ISO.
(3) The operation data are applied to the 220/230/240V districts respectively.
(4) The refrigerant quantity to be charged includes the refrigerant in 15m connecting piping.
(Purging is not required even for the short piping.)
RWA000Z231
A
ꢀꢁ
'10 • SR-T-091D
(4) Ceiling cassette-4way compact type (FDTC)
Adapted to RoHS directive
FDTC25VD
Model
Indoor unit FDTC25VD
Outdoor unit SRC25ZJX-S
Item
Panel TC-PSA-25W-E
Power source
Operation data
Nominal capacity
Power consumption
Running current
Power factor
220/230/240V
Heating
3.45 [ 0.9 (Min.)
0.84
~
50Hz
Cooling
kW
kW
A
2.55 [ 0.9 (Min.)~3.2 (Max.)]
~4.7 (Max.)]
0.6
3.0/2.9/2.8
91
4.1/4.0/3.8
92
%
A
Inrush current
4.1
Cooling P-Hi : 38 Hi : 36 Me : 32 Lo : 29
Heating P-Hi : 39 Hi : 38 Me : 33 Lo : 29.5
Sound Pressure Level
dB(A)
mm
47
Exterior dimensions
Height x Width x Depth
Unit 248 × 570 × 570
Panel 35 × 700 × 700
595 x 780 x 290
Exterior appearance
(Munsell color)
Plaster White
( 6.8Y8.9/0.2 ) near equivalent
Stucco White
( 4.2Y7.5/1.1 ) near equivalent
Net weight
kg
UNIT 15 PANEL 3.5
38
Refrigerant equipment
Compressor type & Q'ty
—
RM-B5077MDE1 (Rotary type) x 1
Starting method
Refrigerant oil
—
Direct line start
—
0.35 (DIAMOND FREEZE MA68)
M shape fin & inner grooved tubing
Electronic expansion valve
Heat exchanger
Refrigerant control
Louver fin & inner grooved tubing
—
Air handling equipment
Fan type & Q'ty
Turbo fan × 1
Propeller fan × 1
Motor <Starting method>
W
CMM
Pa
33 <Direct line start>
24 <Direct line start>
Cooling P-Hi : 10 Hi : 9 Me : 8 Lo : 6.5
Heating P-Hi : 10.5 Hi : 9.5 Me : 8.5 Lo : 7
Cooling 29.5
Heating 27.0
Air flow (Standard)
Available static pressure
Outdoor air intake
0
Not possible
—
—
Air filter, Q'ty
Pocket plastic net × 1 (Washable)
Rubber sleeve (for fan motor)
Polyurethane form
—
—
Shock & vibration absorber
Insulation (noise & heat)
Electric heater
Rubber sleeve (for Compressor)
—
—
W
Remote controller
wired : RC-E4 (option) wireless : RCN-TC-24W-ER (option)
Room temperature control
Thermostat by electronics
—
Overload protection for fan motor
Frost protection thermostat
Internal thermostat for fan motor
Abnormal discharge temperature protection.
Safety equipment
Liquid line : I/U 6.35 (1/4") Pipe 6.35 (1/4") × 0.8 O/U 6.35 (1/4")
φ
φ
φ
Installation data
Refrigerant piping size
mm
Gas line
:
9.52 (3/8")
9.52 (3/8") × 0.8
φ
9.52 (3/8")
φ
φ
Connecting method
Flare piping
Flare piping
Refrigerant line (one way) length
Max. 15m
Vertical height difference between
outdoor unit and indoor unit
Max. 10m (Outdoor unit is higher)
Max. 10m (Outdoor unit is lower)
Refrigerant Quantity
Drain pump
R410A 1.2kg in outdoor unit (incl. the amount for the piping of : 15m)
Built-in Drain pump
—
—
Drain
Hose Connectable with VP20
Insulation for piping
Standard Accessories
Necessary (Both liquid & Gas lines)
Mounting kit, Drain hose
Drain elbow, Drain hole grommet
Notes (1) The data are measured at the following conditions when the air flow is high mode.
Item
Indoor air temperature
Outdoor air temperature
Operation
Cooling
Heating
DB
WB
DB
35˚C
7˚C
WB
24˚C
6˚C
27˚C
19˚C
20˚C
(2) This packaged air-conditioner is manufactured and tested in conformity with the ISO.
(3) Sound pressure level indicates the value in an anechoic chamber. During operation these value are somewhat higher due to
ambient temperature.
(4) The operation data indicates when the air-conditioner is operated at 220/230/240V 50Hz.
(5) When wireless remote controller is used, fan is 3 speed setting (Hi-Me-Lo) only.
RWA000Z234
A
ꢀꢂ
'10 • SR-T-091D
Adapted to RoHS directive
FDTC35VD
Model
Indoor unit FDTC35VD
Outdoor unit SRC35ZJX-S
Item
Panel TC-PSA-25W-E
Power source
Operation data
Nominal capacity
Power consumption
Running current
Power factor
220/230/240V
Heating
4.25 [ 0.9 (Min.)
1.16
~
50Hz
Cooling
kW
kW
A
3.6 [ 0.9 (Min.)~4.1 (Max.)]
~5.1 (Max.)]
1.07
4.9/4.7/4.5
99
5.3/5.1/4.9
99
%
A
Inrush current
5.3
Cooling P-Hi : 41 Hi : 40 Me : 36 Lo : 30
Heating P-Hi : 43 Hi : 42 Me : 35 Lo : 32
Sound Pressure Level
dB(A)
mm
50
Exterior dimensions
Height x Width x Depth
Unit 248 × 570 × 570
Panel 35 × 700 × 700
595 x 780 x 290
Exterior appearance
( Munsell color )
Plaster White
( 6.8Y8.9/0.2 ) near equivalent
Stucco White
( 4.2Y7.5/1.1 ) near equivalent
Net weight
kg
UNIT 15 PANEL 3.5
38
Refrigerant equipment
Compressor type & Q'ty
—
RM-B5077MDE1 (Rotary type) x 1
Starting method
Refrigerant oil
—
Direct line start
—
0.35 (DIAMOND FREEZE MA68)
M shape fin & inner grooved tubing
Electronic expansion valve
Heat exchanger
Refrigerant control
Louver fin & inner grooved tubing
—
Air handling equipment
Fan type & Q'ty
Turbo fan × 1
Propeller fan × 1
Motor <Starting method>
W
CMM
Pa
33 <Direct line start>
24 <Direct line start>
Cooling P-Hi : 11 Hi : 9.5 Me : 9 Lo : 7
Heating P-Hi : 11.5 Hi : 10.0 Me : 9 Lo : 8
Cooling 32.5
Heating 29.5
Air flow (Standard)
Available static pressure
Outdoor air intake
0
Not possible
—
—
Air filter, Q'ty
Pocket plastic net × 1 (Washable)
Rubber sleeve (for fan motor)
Polyurethane form
—
—
Shock & vibration absorber
Insulation (noise & heat)
Electric heater
Rubber sleeve (for Compressor)
—
—
W
Remote controller
wired : RC-E4 (option) wireless : RCN-TC-24W-ER (option)
Room temperature control
Thermostat by electronics
—
Overload protection for fan motor
Frost protection thermostat
Internal thermostat for fan motor
Abnormal discharge temperature protection.
Safety equipment
Liquid line : I/U 6.35 (1/4") Pipe 6.35 (1/4") × 0.8 O/U 6.35 (1/4")
φ
φ
φ
Installation data
Refrigerant piping size
mm
Gas line
:
9.52 (3/8")
9.52 (3/8") × 0.8
φ
9.52 (3/8")
φ
φ
Connecting method
Flare piping
Flare piping
Refrigerant line (one way) length
Max. 15m
Vertical height difference between
outdoor unit and indoor unit
Max. 10m (Outdoor unit is higher)
Max. 10m (Outdoor unit is lower)
Refrigerant Quantity
Drain pump
R410A 1.2kg in outdoor unit (incl. the amount for the piping of : 15m)
Built-in Drain pump
—
—
Drain
Hose Connectable with VP20
Insulation for piping
Standard Accessories
Necessary (Both liquid & Gas lines)
Mounting kit, Drain hose
Drain elbow, Drain hole grommet
Notes (1) The data are measured at the following conditions when the air flow is high mode.
Item
Indoor air temperature
Outdoor air temperature
Operation
Cooling
Heating
DB
WB
DB
35˚C
7˚C
WB
24˚C
6˚C
27˚C
19˚C
20˚C
(2) This packaged air-conditioner is manufactured and tested in conformity with the ISO.
(3) Sound pressure level indicates the value in an anechoic chamber. During operation these value are somewhat higher due to
ambient temperature.
(4) The operation data indicates when the air-conditioner is operated at 220/230/240V 50Hz.
(5) When wireless remote controller is used, fan is 3 speed setting (Hi-Me-Lo) only.
RWA000Z234
A
ꢀꢃ
790
Symbol
A
Content
14.5
60
60
31
20㨪35 Ǿ9.52㧔3㧛8"㧕㧔Flare㧕
50 Ǿ12.7㧔1㧛2"㧕㧔Flare㧕
Gas piping
Model
Liquid piping
B
C
D
E
Ǿ6.35㧔1㧛4"㧕㧔Flare㧕
㧔Ǿ65㧕
㧔Ǿ65㧕
Hole on wall for right rear piping
Hole on wall for left rear piping
Drain hose
VP16
Outlet for wiring
F
Outlet for piping㧔on both side㧕
G
229
3
798
G
Wireless remote controller
Outlet for down piping
㧔Refer to the above view㧕
45
60
17.3
㧔Service space㧕
Installation plate
Unit
Wired - remote controller
50
F
㧔Option㧕
㧔Service space㧕
106.5
139
585
450
106.5
209
100
غ 120 19
Notes㧔1㧕The model name label is attached
ޓ ޓ ޓ on the underside of the panel. ޓ 㧔2㧕It takes the interface kit 㧔SC-BIKN-E㧕 ޓ ޓ ޓ to connect the wired remote controller. Unit:mm
55
55
C
D
E
B
A
403.6
471.6
531.8
Space for installation and service when viewing from the front
881.9
Symbol
A
Content
26
59.9
59.9
20.9
Model 20,25,35
Model 50,60
Ǿ6.35㧔1㧛4"㧔㧕Flare㧕
㧔Ǿ65㧕
㧔Ǿ65㧕
VP16
Ǿ9.52㧔3㧛8"㧔㧕Flare㧕
Ǿ12.7㧔1㧛2"㧔㧕Flare㧕
Gas piping
Liquid piping
B
C
D
E
Hole on wall for right rear piping
Hole on wall for left rear piping
Drain hose
Outlet for wiring
F
Outlet for piping㧔on both side㧕
G
220
3
890
G
Wireless remote controller
Outlet for down piping
㧔Refer to the above view㧕
Terminal block
46.5
60
17.3
61.5
F
Installation plate
Wired - remote controller
㧔Service space㧕
㧔Service space㧕
㧔Option㧕
50
120
220
650
120
220
100
450
Unit
غ 120 19
35
35
Notes㧔1㧕The model name label is attached
ޓ ޓ ޓ on the underside of the panel. ޓ 㧔2㧕It takes the interface kit 㧔SC-BIKN-E㧕 ޓ ޓ ޓ to connect the wired remote controller. Unit:mm
54
B
A
D
C
58
491.1
520.8
559.1
E
Symbol
A
Content
83.5
620
726
156.5
103.5
211.5
25,35 : Ǿ9.52㧔3㧛8"㧕㧔Flare㧕
50 : Ǿ12.7㧔1㧛2"㧕㧔Flare㧕
Ǿ6.35㧔1㧛4"㧕㧔Flare㧕
Installation plate
Unit
Gas piping
Model
30.5
138.5
255
255
Liquid piping
B
C
D
E
Hole on wall for right rear piping
Hole on wall for left rear piping
Drain hose
㧔Ǿ65㧕
㧔Ǿ65㧕
VP16
F
Screw point fasten the indoor unit
Outlet for piping㧔on both side㧕
F
G
Ǿ5
F
A
B
35
10
840
10
76.3
157.2
85.3
22.7
F
F
D
E
C
㧔Service space㧕
50 65
65
30.5
804
25.5
50+Service space
482.8
Space for installation and service when viewing from the front
860
238
Wireless remote controller
Wired remote controller
㧔Option㧕
60
غ 120 19
17.3
Notes
㧔1㧕Themodelnamelabelisattachedontherightsideoftheunit.
ޓ 㧔2㧕Ittakestheinterfacekit㧔SC-BIKN-E㧕toconnectthewiredremotecontroller. 㧔3㧕Incaseofwallinstallation,leavetheunit150mmorlessfromthefloor.
G
6
Unit:mm
12
Outlet for down piping
㧔Refer to the above view㧕
60
15
11
190
160
30.3
174.4
40
52
41
148
170
30
19
(Suspension bolts pitch)
515
13
30
30
30
230
11.2
253
455
150
150
120
20
150
80
21
177
32
20
80 40
11.3
203.7
Decorative panel
530(Suspension bolts pitch)
G
Symbol
A
Content
φ
Gas piping
9.52(
3
/
/
8"()Flare
4"()Flare
)
)
Liquid piping
Drain piping
Hole for wiring
φ
6.35
(
1
B
C
D
F
VP20
(
I.D.20,O.D.26
)
Note
(2)
φ
25
Suspension bolts
(
M10 or M8
)
Ducting for air outlet
G
(Knock out
)
G
G
Space for installation and service
Control
box
Air return
grille
1000 or more
Air supply
185
190
D
Obstacle
223
□
□
413
700
21
200
Make a space of 4000 or more between
the units when installing more than one.
48
Drain hose piece
Accessory
(
)
140
60
φ
6-
4
Installed on site
(
)
Holes for
□
570
325
Remote controller
tapping screws
(
Option)
295 325
F
C
B
A
145
Hole
100
□
120
19
G
Hanger plate for
suspension bolt
Unit:mm
Notes(1)The model name label is attached on the control box lid.
VP20 on site.
(2)Prepare the connecting socke
(
t
)
(3)This unit is designed for 2x2 grid ceiling.
If it is installed on a ceiling other than 2x2 grid ceiling,
provide an inspection port on the control box side.
Notes
(1)It must not be surrounded by walls on the four sides.
(2)The unit must be fixed with anchor bolts. An anchor bolt must not
protrude more the 15mm.
(3)Where the unit is subject to strong winds, lay it in such
a direction that the blower outlet faces perpendicularly
to the dominant wind direction.
(4)Leave 1m or more space above the unit.
(5)A wall in front of the blower outlet must not exceed the units height.
(6)The model name label is attached on the right side of the unit.
Symbol
Content
Service valve connection(gas side)
A
B
C
D
E
φ12.7(1/2")(Flare)
Service valve connection(liquid side)
Pipe/cable draw-out hole
Drain discharge hole
φ6.35(1/4")(Flare)
φ20 × 5places
Anchor bolt hole
M10 × 4places
520.6
161
327.3
50.6
12
38.6
D
E
L3
Intake
L4
L2
Service
space
(
)
Intake
Outlet
L1
327.3
89
510
201
17.9
71.2
Minimum installation space
800
Examples of
installation
I
II
III
IV
Dimensions
L1
L2
L3
L4
Open
100
280
Open
80
280
75
180
Open
Terminal block
100
80
Open
80
Open
250
250
148.4
33.5
C
B
Unit:mm
A
Notes
(1)It must not be surrounded by walls on the four sides.
(2)The unit must be fixed with anchor bolts. An anchor bolt must not
protrude more the 15mm.
(3)Where the unit is subject to strong winds, lay it in such
a direction that the blower outlet faces perpendicularly
to the dominant wind direction.
Symbol
Content
Service valve connection(gas side)
A
B
C
φ9.52(3/8")(Flare)
Service valve connection(liquid side)
Pipe/cable draw-out hole
Drain discharge hole
φ6.35(1/4")(Flare)
φ20 × 2places
D
E
Anchor bolt hole
M10 × 4places
(4)Leave 1m or more space above the unit.
(5)A wall in front of the blower outlet must not exceed the units height.
(6)The model name label is attached on the lower right corner of the front panel.
390.6
50.6
12
E
D
L3
Intake
L4
L2
Service
space
(
)
Intake
Outlet
L1
390.6
111.6
510
780
158.4
17.9
61.9
Minimum installation space
Examples of
installation
I
II
III
IV
Dimensions
L1
L2
L3
L4
Open
100
280
Open
80
280
75
180
Open
Terminal block
100
80
Open
80
Open
250
250
138.4
33.5
C
B
Unit:mm
A
Notes
(1)It must not be surrounded by walls on the four sides.
(2)The unit must be fixed with anchor bolts. An anchor bolt must not
protrude more the 15mm.
(3)Where the unit is subject to strong winds, lay it in such
a direction that the blower outlet faces perpendicularly
to the dominant wind direction.
(4)Leave 1m or more space above the unit.
(5)A wall in front of the blower outlet must not exceed the units height.
(6)The model name label is attached on the lower right corner of the front panel.
Symbol
Content
Service valve connection(gas side)
A
B
C
D
E
φ12.7(1/2")(Flare)
Service valve connection(liquid side)
Pipe/cable draw-out hole
Drain discharge hole
φ6.35(1/4")(Flare)
φ20 × 5places
Anchor bolt hole
M10 × 4places
520.6
161
327.3
50.6
12
38.6
D
E
L3
Intake
L4
L2
Service
space
(
)
Intake
Outlet
L1
327.3
89
510
201
17.9
Minimum installation space
800
71.2
Examples of
installation
I
II
III
IV
Dimensions
L1
L2
L3
L4
Open
100
280
Open
80
280
75
180
Open
Terminal block
100
80
Open
80
Open
250
250
148.4
33.5
C
B
Unit:mm
A
'10 • SR-T-091D
(3) Remote controller
(a) Wireless remote controller
Models SRK, SRF, SRR
٨ The wireiess remote controller in the following figure shows for the SRK-50ZJ-S type.
Unit: mm
60
17.3
Model FDTC (Option parts)
60
17
23
'10 • SR-T-091D
(b) Wired remote controller (option parts)
Wiring outlet
Cut off the upper thin part of remote control lower case with a nipper or knife,
and grind burrs with a file etc.
Exposed mounting
In case of pulling out
from upper left
In case of pulling out
from center
0.3mm2×2 cores.
48
Upper part
In case of pulling out
from center
In case of pulling out
from upper left
Lower case
L C D
Lower part
Sheath
TEMP
ON/OFF
Sheath
Upper
Board
Upper
Upper cace
Upper cace
Board
X
Y
X
Y
Lower
Lower
Wiring
Wiring
X, Y Terminal block
Attach M3 screw
with washer
In case of pulling out from center
In case of pulling out from
upper left
The peeling-off length of sheath
غ 120 Pulling out from upper left Pulling out from center
X wiring : 215mm
Y wiring : 195mm
X wiring : 170mm
Y wiring : 190mm
The peeling-off length
of sheath
Embedded mounting
Remote control installation dimensions
120
Wall surface
Tighten the screws after
cutting off the thin part of
screw mounting part.
Remote
control
outline
46
23
Wiring
44
11.5
11
Wiring oulet
Electrical box
12×7 Slot hole
Installation hole
9.5×5 Slot hole 䋨4places䋩
䋨Not included䋩
䋨1䋩 Installation screw for remote control
M4 Screw (2 pieces)
19
Unit:mm
Wiring specifications
(1) If the prolongation is over 100m, change to the size below.
2
But, wiring in the remote controller case should be under 0.5mm . Change the wire size outside of
the case according to wire connecting. Waterproof treatment is necessary at the wire connecting
section. Be careful about contact failure.
Length
Wiring thickness
2
100 to 200m
Under 300m
Under 400m
Under 600m
0.5mm ×2 cores
2
0.75mm ×2 cores
2
1.25mm ×2 cores
2
2.0mm ×2 cores
PJZ000Z274
24
LM2
LM1
SMI
FMI
Description
Item
CNE-CNY Connector
M
M
M
M
Fan motor
FMI
SMI
LM1,2
HD
ThI
Th2,3
DS
F
Flap motor
Louver motor
5
5
5
Humidity sensor
Room temp. sensor
Heat exch. sensor
Diode stack
1
3
4
5
6
CNY
CNX
CNM
CNU
G
Fuse
PRINTED
CIRCUIT
BOARD
T
Va
Terminal block
Varistor
HEAT
EXCHANGER
F
L
㨪
㨪
Mark
Color
250V 3.15A
Va
BK
BL
RD
WH
Y
Black
U
Blue
Red
S/N
White
Yellow
DS
J
Y㧛G Yellow㧛Green
HEAT
EXCHANGER
CNS
5
CNF
CNE
CNG
2
2
2
2
8
to
to
to
DISPLAY
WIRELESS
R-AMP
1
2/N
3
Power Source
1 Phase
220㧛230㧛240V 50Hz
T
BACK-UP SW
HD
̪
Th3
Th2
ThI
̪35,50
ONLY
TO OUTDOOR
UNIT
Description
Item
CNE-CNY Connector
Fan motor
FMI
SM1,2
LM1,2
IM
Th1
Th2 1,2
Th3
LS
5
5
5
5
DISPLAY
WIRELESS RECEIVER
BACK-UP SW
M
M
M
LM1
LM2
12
Flap motor
Louver motor
Inlet motor
CNE
CNG
CNX1
CNX2
PRINTED
CIRCUIT
BOARD
t
Th1
Room temp. sensor
Heat exch. sensor
Humidity sensor 㧔50,60 only㧕
Limit switch
5
5
5
5
SM1
SM2
t
Th2
Th2
1
2
DS
M
DS
Diode stack
t
F
Fuse
T
Terminal block
Varistor
5
5
M
IM
Va
2
5
CNF
CNS
Th3
CNY
LS
INTERFACE KIT
SC-BIKN-E
Color Marks
Mark
Color
G
Y㧛G
BK
Black
U
Va
BL
RD
WH
Y
Blue
RD
WH S㧛N
1
BK
WH
Y
Red
3
4
5
6
F
J
RD
HEAT
EXCHANGER
CNU
250V
3.15A
M
White
Yellow
BL
L
BK
FMI
Y㧛G Yellow㧛Green
Power source
1 phase 220 - 240 V 50Hz
T
TO OUTDOOR UNIT
1
2㧛N
3
2/N
POWER WIRES
SIGNAL WIRE
1
3
HEAT
EXCHANGER
Description
Item
CNE-CNX2 Connector
DISPLAY
WIRELESS RECEIVER
BACK-UP SW
Fan motor
FMI
SM1,2
DM1
DM2
Th1
Th2 1,2
Th3
DS
5
5
5
5
10
M
M
M
DM1
DM2
CNE
CNG
Flap motor
CNX1
CNX2
AIR SELECTION SW
Damper motor
Damper arm motor
Room temp. sensor
Heat exch. sensor
Humidity sensor
Diode stack
PRINTED
CIRCUIT
BOARD
t
Th1
5
5
5
5
SM1
SM2
t
Th21
DS
M
F
Fuse
t
Th22
T
Terminal block
Varistor
Va
2
5
CNF
CNS
Th3
INTERFACE KIT
SC-BIKN-E
Color Marks
Mark
Color
G
Y㧛G
BK
Black
U
Va
BL
Blue
RD
WH S㧛N
1
BK
WH
YE
RD
WH
YE
Red
3
4
5
6
F
J
RD
HEAT
EXCHANGER
CNU
250V
3.15A
M
White
Yellow
BL
L
BK
FMI
Y㧛G Yellow㧛Green
Power source
1 phase 220 - 240 V 50Hz
T
TO OUTDOOR UNIT
1
2㧛N
3
2/N
POWER WIRES
SIGNAL WIRE
1
3
HEAT
EXCHANGER
FM
M
CONTROL
BOX
1
3
4
5
6
CNU
5
INTERFACE KIT
SC-BIKN-E
CNS
F
250V
0.16A
DM
S㧛N
WH
RD
RD
M
U
CNW
Va
1㨪
L
BK
RD
F
250V 3.15A
J
FS
WH
WH
Y㧛G
G
PRINTED CIRCUIT
BOARD
CNY
CNE
CNG
2
2
BK
8
T
2
2
1
2/N
3
10
Power source
1 phase 220 - 240 V 50Hz
DISPLAY
TO OUTDOOR UNIT
WIRELESS
RECEIVER
TO OUTDOOR UNIT
Description
Th1 Th2
Description
Th3
2/N
POWER WIRES
SIGNAL WIRE
1
3
Color Marks
Mark
Meaning of Marks
Item
Color
Mark
YE
Y㧛G
Color
Item
BK
BL
Black
Blue
Yellow
Yellow㧛Green
CNE-CNY
F
Connector
Fuse
Fan motor
Drain motor
Float Switch
Th1
Th2
Th3
T
Room temp. sensor
Heat exch. sensor 1
Heat exch. sensor 2
Terminal block
OR
RD
WH
Orange
Red
White
FM
DM
FS
I
Va
Varistor
Color Marks
LED・3
LM1~4
SW2
Indication lamp(Red-Inspection)
TB1
Terminal bloc(k Power source)
(□ mark)
Terminal bloc(k Signal line()□mark)
Thermisto(r Remote controller)
Thermisto(r Return air)
Thermisto(r Heat exchanger)
Relay for DM
Mark Color
BK Black
BL Blue
BR Brown
OR Orange
RD Red
CNB~Z
DM
F200~203
Connector
Drain motor
Fuse
Fan motor
Float switch
Indication lamp
(Green-Normal operation)
Louver motor
TB2
Thc
ThI-A
ThI-R1,2,3
X4
Remote controller communication
address
Plural units Master/Slave setting
Model capacity setting
FM
FS
I
SW5
SW6
SW7-1
LED・2
Operation check,Drain motor test run
WH White
■ mark
Closed-end connector
Y
Yellow
Y/GN Yellow/Green
Remote controller
TB2
Control PCB
FS
WH
1
1
WH
WH
WH
WH
RD
1
X
Y
X
Y
CNB
1
CNI
BL
BK
WH
3
ThC
t°
2
2
RD
2
LED・2
LED・3
CNI2
WH
Y/GN
BL
BL
3
4
BL
BL
1
BK
1
Y/GN
Y/GN
CNH
BK
ThI-A
t°
t°
t°
t°
2
BK
2
Power PCB
RD
RD
RD
RD
RD
CNH2
WH
BK
1
1
Y/GN
2
2
Connecting line between
Y/GN
RD
7
5
3
CNW3
CNW2
RD
RD
RD
5
6
RD
RD
1
SW2
3
4
5
3
1
F200(3.15A)
indoor unit and outdoor unit
RD
4
1
2
3
ThI-R1
ThI-R2
ThI-R3
2
BK
Power circuit
2
1
2
WH
5
2
Power source line
Signal line
Earth
3
F201(3.15A)
BL
1
CNW1
BL
BL
BL
BL
BL
BL
1
2
3
SW5
SW6
SW7
Y
Y
7
8
Y
Y
3
4
BK
BK
1 CNW4
[ ]
3
4
CNW0
WH
CNN
Y
X4
3
Y/GN
BL
TB1
4
5
F203
(0.16A)
F202
(1.0A)
4
5
1
3
1
4
5
6
7
BK
BK
9
BK
BK
5
6
BK
5
6
RD BL BR OR WH
WH BR
CNR
WH
CNM
WH
10
BK
1
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
1
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
1
2
3
4
5
6
7
8
9
LM1
M
CNN2
BK
2
Y
1
CNC
WH
2
2
5
6
4
3
2
CNR2
BL
CNM3
3
4
5
3
4
Y
RD BL BR OR WH
RD
5
5
6
4
3
2
1
6
M
1~
DM
CNM4
WH
LM2
M
2
3
4
5
7
RD BL BR OR WH
Option
8
+12
1
9
2
3
4
5
6
XR1
(Operation)
(Heating)
M
10
11
12
13
14
15
16
17
18
19
20
CNJ
10
FMI
CNT
BL
XR2
XR4
1
WH
11
12
13
14
15
16
17
18
19
20
(Compressor ON)
(Inspection)
XR3
LM3
M
2
3
4
5
XR5(Remote operation input:volt-free contact)
1
Notes 1.
indicates wiring on site.
LM4
M
2
3
4
5
2. TB1 is the terminal block for heavy current(connecting line between
indoor unit and outdoor unit),
and TB2 is the terminal block for weak current(remote controller).
3. See the wiring diagram of outside unit about the line between
inside unit and outside unit.
CNJ2
WH
4. Use twin core cable(0.3mm2X2)at remote controller line. See spec
sheet of remote controller in case that the total length is more than 100m.
5. Do not put remote controller line alongside power source line.
POWER SOURCE 1~220ー240V 50Hz/1~220V 60Hz
Item
Description
Compressor motor
CNEEV~CN20S Connector
CM
EEV
FMo
L
Electric expansion valve(coil)
Fan motor
L
Reactor
T1,2
TH1
TH2
TH3
20S
Terminal block
Heat exchanger sensor(outdoor unit)
Outdoor air temp.sensor
Discharge pipe temp.sensor
Solenoid valve for 4 way valve
TERMINAL
BLOCK
PWB ASSY (MAIN)
PWB ASSY (SUB)
POWER
TRANSISTOR
T1
L
FUSE
R
IN
(BK)
F8
F2
U
V
(RD)
(WH)
(BK)
P
R
O
O
R
U
250V 20A
(BK)
(WH)
(WH)
(BK)
ACTIVE
FILTER
UNIT
250V 20A
250V 20A
(WH) S IN
+
+
+
NU
V
M
N
S
S
3~
(WH)
NV
NW
W
(BR)
W
(Y/G)
CM
R
OUT
S-1
S-2
Mark
BK
Color
Black
Brown
G1
(Y/G)
TERMINAL
BLOCK
CNMAIN
CNSUB
C-2
CN20S
(RD)
BR
T2
1
F3 250V 1A
OR
RD
Orange
Red
TO INDOOR UNIT
2
M
N
WH
Y
White
CNFAN
2
(RD)
POWER WIRES
SIGNAL WIRE
1
3
N
FMo
3
SWITCHING POWER
CIRCUIT
Yellow
[
]
(Y/G)
Y/G
Yellow/Green
CNTH
CNEEV
20S
M
t゜
t゜
t゜
EEV
5 or 6 wires
TH1 TH2 TH3
Power cable, indoor-outdoor connecting wires
Model
MAX running current
Power cable size
Power cable length
indoor-outdoor
wire size x number
Earth wire size
(mm)
(mm2
)
(m)
(A)
50
2.0
φ1.6mm x 3
φ1.6mm
14
18
The specifications shown in the above table are for units without heaters. For units with heaters, refer
to the installation instructions or the construction instructions of the indoor unit.
Switchgear of Circuit breaker capacity which is calculated from MAX. over current should be chosen
along the regulations in each country.
The cable specifications are based on the assumption that a metal or plastic conduit is used with no
more than three cables contained in a conduit and a voltage drop is 2%. For an installation falling
outside of these conditions, please follow the internal cabling regulations. Adapt it to the regulation
in effect in each country.
Item
Description
Compressor motor
CM
Connector
CN20S
CNTH
L
TO INDOOR UNIT
POWER WIRES
CNEEV
CNFAN
2
1
3
N
EEV
FMo
L
Electric expansion valve(coil)
Fan motor
[
]
SIGNAL WIRE
PWB ASSY
Reactor
POWER
T1 T2
POWER SOURCE
~220ー240V 50Hz/~220V 60Hz
T
Terminal block
TRANSISTOR
250V 15A
t゜
F2
(BK) R.IN
TH1
TH2
TH3
20S
Heat exchanger sensor(outdoor unit)
Outdoor air temp.sensor
Discharge pipe temp.sensor
Solenoid valve for 4 way valve
(RD)
(WH)
(BK)
P
U
V
L
1
2
3
U
+ +
250V 20A
NOISE
FILTER
M
V
N
3~
W
(WH) S.IN
W
N
CM
F3 250V 1A
(Y/G)
PAM
(RD) C-2
F4
CIRCUIT
Mark
BK
Color
Black
M
(Y/G) G1
CNFAN
250V 10A
TERMINAL
BLOCK
FMo
SWITCHING POWER
CIRCUIT
OR
RD
Orange
Red
T
CN20S
CNEEV
CNTH
WH
Y
White
t゜ t゜ t゜
Yellow
M
20S
Y/G
Yellow/Green
EEV
5 or 6 wires
TH1 TH2 TH3
Power cable, indoor-outdoor connecting wires
Model
MAX running current
Power cable size
Power cable length
indoor-outdoor
wire size x number
Earth wire size
(mm)
(mm2
)
(m)
(A)
20
25
35
8
2.0
32
φ1.6mm x 3
φ1.6mm
The specifications shown in the above table are for units without heaters. For units with heaters, refer
to the installation instructions or the construction instructions of the indoor unit.
Switchgear of Circuit breaker capacity which is calculated from MAX. over current should be chosen
along the regulations in each country.
The cable specifications are based on the assumption that a metal or plastic conduit is used with no
more than three cables contained in a conduit and a voltage drop is 2%. For an installation falling
outside of these conditions, please follow the internal cabling regulations. Adapt it to the regulation
in effect in each country.
POWER SOURCE 1~220ー240V 50Hz/1~220V 60Hz
Item
Description
Compressor motor
CM
CNEEV~20S
Connector
EEV
FMo
L
Electric expansion valve(coil)
Fan motor
L
Reactor
T1,2
TH1
TH2
TH3
20S
Terminal block
Heat exchanger sensor(outdoor unit)
Outdoor air temp.sensor
Discharge pipe temp.sensor
Solenoid valve for 4 way valve
TERMINAL
BLOCK
PWB ASSY (MAIN)
PWB ASSY (SUB)
POWER
TRANSISTOR
T1
FUSE
R
IN
(BK)
F8
F2
L
U
V
(RD)
(WH)
(BK)
P
R
O
O
R
U
250V 20A
(BK)
(WH)
(WH)
(BK)
ACTIVE
FILTER
UNIT
250V 20A
250V 20A
(WH) S IN
+
+
+
NU
V
M
N
S
S
3~
(WH)
NV
NW
W
(BR)
W
(Y/G)
CM
R
OUT
S-1
S-2
Mark
BK
Color
Black
G1
(Y/G)
TERMINAL
BLOCK
CNMAIN
CNSUB
C-2
CN20S
(RD)
BR
Brown
T2
F3 250V 1A
OR
RD
Orange
Red
1
TO INDOOR UNIT
2
M
N
WH
Y
White
CNFAN
2
(RD)
POWER WIRES
SIGNAL WIRE
1
3
N
FMo
3
SWITCHING POWER
CIRCUIT
Yellow
[
]
(Y/G)
Y/G
Yellow/Green
CNTH
CNEEV
20S
M
t゜
t゜
t゜
EEV
5 or 6 wires
TH1 TH2 TH3
Power cable, indoor-outdoor connecting wires
Model
MAX running current
Power cable size
Power cable length
indoor-outdoor
wire size x number
Earth wire size
(mm)
(mm2
)
(m)
(A)
40
50
60
12
21
2.0
φ1.6mm x 3
φ1.6mm
14
18
The specifications shown in the above table are for units without heaters. For units with heaters, refer
to the installation instructions or the construction instructions of the indoor unit.
Switchgear of Circuit breaker capacity which is calculated from MAX. over current should be chosen
along the regulations in each country.
The cable specifications are based on the assumption that a metal or plastic conduit is used with no
more than three cables contained in a conduit and a voltage drop is 2%. For an installation falling
outside of these conditions, please follow the internal cabling regulations. Adapt it to the regulation
in effect in each country.
INVERTER RESIDENTIAL AIR CONDITIONERS
Air-Conditioning & Refrigeration Systems Headquarters
16-5, 2-chome, Kounan, Minato-ku, Tokyo, 108-8215, Japan
Fax : (03) 6716-5926
Because of our policy of continuous improvement, we reserve the right to make changes in all specifications without notice.
C
Copyright MITSUBISHI HEAVY INDUSTRIES, LTD.
|