Mitsubishi Electronics Srk507j S User Manual

DRAFT  
Manual No.'10•SR-T-091D  
TECHNICAL MANUAL  
INVERTER RESIDENTIAL AIR CONDITIONERS  
(Split system, air to air heat pump type)  
Wall mounted type Floor standing type Ceiling concealed type  
SRK50ZJ-S  
SRF25ZJX-S  
SRF35ZJX-S  
SRF50ZJX-S  
SRR25ZJ-S  
SRR35ZJ-S  
SRK20ZJX-S  
SRK25ZJX-S  
SRK35ZJX-S  
SRK50ZJX-S  
SRK60ZJX-S  
Ceiling cassette-4way compact type  
FDTC25VD  
FDTC35VD  
'10 • SR-T-091D  
1. SPECIFICATIONS  
(1) Wall mounted type (SRK)  
Adapted to RoHS directive  
SRK50ZJ-S  
Model  
Item  
Indoor unit SRK50ZJ-S  
5000 (1600 (Min.)  
5800 (1600 (Min.)  
1 Phase, 220  
Outdoor unit SRC50ZJ-S  
Cooling capacity (1)  
Heating capacity (1)  
Power supply  
W
W
~
~
~
5500 (Max.))  
6600 (Max.))  
240 V, 50Hz  
Cooling  
Heating  
Cooling  
Heating  
1.55 (0.40  
~
2.10)  
2.20)  
Power  
consumption  
kW  
A
1.59 (0.42~  
7.1 / 6.8 / 6.5 (220/ 230/ 240 V)  
7.3 / 7.0 / 6.7 (220/ 230/ 240 V)  
7.3 / 7.0 / 6.7 (220/ 230/ 240 V)  
3.23  
Running  
current  
Inrush current  
Operation  
data (1)  
Cooling  
COP  
Heating  
3.65  
Sound level  
Power level  
Sound level  
Power level  
dB(A)  
dB  
Hi : 46 Me : 37 Lo : 26  
51  
Cooling  
Heating  
61  
Hi : 45 Me : 37 Lo : 31  
61  
61  
Noise  
level  
dB(A)  
dB  
53  
63  
Exterior dimensions (Height x Width x Depth)  
mm  
294 x 798 x 229  
640 x 800 (+71) x 290  
Exterior appearance  
(Munsell color)  
Fine snow  
( 8.0Y 9.3/0.1 ) near equivalent  
Stucco white  
( 4.2Y 7.5/1.1 ) near equivalent  
Net weight  
kg  
kW  
kg  
9.5  
42  
Compressor type & Q'ty  
Motor (Starting method)  
5RS132XAB21 (Rotary type) x 1  
0.90 (Line starting)  
Refrigerant oil  
0.37 (FV50S)  
R410A 1.35 (Pre-Charged up to the piping length of 15m)  
Louver fins & inner grooved tubing M fins & inner grooved tubing  
Refrigerant  
equipment  
Refrigerant (4)  
Heat exchanger  
Refrigerant control  
Deice control  
Fan type & Q'ty  
Motor  
Capillary tubes + Electronic expansion valve  
Microcomputer control  
Tangential fan x 1  
38  
Propeller fan x 1  
34  
W
Cooling  
Heating  
Hi : 11.3 Me : 7.8 Lo : 5.3  
Hi : 13.5 Me : 10.2 Lo : 7.5  
Not possible  
36.0  
Air handling  
equipment  
Air flow  
CMM  
36.0  
Fresh air intake  
Air filter, Quality / Quantity  
Polypropylene net (washable) x 2  
Shock & vibration absorber  
Electric heater  
Cushion rubber (for compressor)  
Operation switch  
Wireless-Remote control  
Microcomputer thermostat  
Operation  
control  
Room temperature control  
Operation Display  
RUN : Green, TIMER : Yellow, HI POWER : Green, 3D AUTO : Green  
Compressor overheat protection, Overcurrent protection,  
Safety devices  
Frost protection, Serial signal error protection, Indoor fan motor error protection,  
Heating overload protection (High pressure control), Cooling overload protection  
Refrigerant piping size (O.D)  
Connecting method  
mm  
m
Liquid line : 6.35 (1/4") Gas line : 12.7 (1/2")  
φ
φ
Flare connecting  
Liquid line : 0.53  
Gas line : 0.40  
Attached length of piping  
Installation  
data  
Insulation for piping  
Necessary (Both sides), independent  
Max. 25  
Refrigerant line (one way) length  
m
A
Vertical height difference between  
outdoor unit and indoor unit  
Max. 15 (Outdoor unit is higher)  
Max. 15 (Outdoor unit is lower)  
Drain hose  
Connectable (VP16)  
Power cable  
Recommended breaker size  
16  
Size x Core number  
Connecting method  
1.5mm2 x 4 cores (Including earth cable)  
Terminal block (Screw fixing type)  
Connection wiring  
Accessories (included)  
Optional parts  
Mounting kit, Clean filter (Allergen clear filter x 1, Photocatalytic washable deodorizing filter x 1)  
Interface kit (SC-BIKN-E)  
The pipe length is 7.5m.  
Note (1) The data are measured at the following conditions.  
Item  
Indoor air temperature  
Outdoor air temperature  
Standards  
DB  
WB  
19˚C  
DB  
35˚C  
7˚C  
WB  
24˚C  
6˚C  
Operation  
Cooling  
Heating  
27˚C  
20˚C  
ISO-T1, JIS C 9612  
(2) This air-conditioner is manufactured and tested in conformity with the ISO.  
(3) The operation data are applied to the 220/230/240V districts respectively.  
(4) The refrigerant quantity to be charged includes the refrigerant in 15m connecting piping.  
(Purging is not required even for the short piping.)  
RWA000Z225  
B
'10 • SR-T-091D  
Adapted to RoHS directive  
SRK20ZJX-S  
Model  
Item  
Indoor unit SRK20ZJX-S  
2000 (900 (Min.)  
2500 (900 (Min.)  
1 Phase, 220  
Outdoor unit SRC20ZJX-S  
Cooling capacity (1)  
Heating capacity (1)  
Power supply  
W
W
~
~
~
3100 (Max.))  
4300 (Max.))  
240 V, 50Hz  
Cooling  
Heating  
Cooling  
Heating  
0.35 (0.19  
~
1.00)  
0.70)  
Power  
consumption  
kW  
A
0.45 (0.23~  
1.9 / 1.8 / 1.7 (220/ 230/ 240 V)  
2.4 / 2.3 / 2.2 (220/ 230/ 240 V)  
2.4 / 2.3 / 2.2 (220/ 230/ 240 V)  
5.71  
Running  
current  
Inrush current  
Operation  
data (1)  
Cooling  
COP  
Heating  
5.56  
Sound level  
Power level  
Sound level  
Power level  
dB(A)  
dB  
Hi : 39 Me : 30 Lo : 21  
47  
Cooling  
Heating  
53  
Hi : 38 Me : 33 Lo : 25  
54  
60  
Noise  
level  
dB(A)  
dB  
47  
59  
Exterior dimensions (Height x Width x Depth)  
mm  
309 x 890 x 220  
595 x 780 (+62) x 290  
Exterior appearance  
(Munsell color)  
Fine snow  
( 8.0Y 9.3/0.1 ) near equivalent  
Stucco white  
( 4.2Y 7.5/1.1 ) near equivalent  
Net weight  
kg  
kW  
kg  
15  
38  
Compressor type & Q'ty  
Motor (Starting method)  
RM-B5077MDE1 (Rotary type) x 1  
0.75 (Line starting)  
Refrigerant oil  
0.35 (DIAMOND FREEZE MA68)  
R410A 1.2 (Pre-Charged up to the piping length of 15m)  
Louver fins & inner grooved tubing M fins & inner grooved tubing  
Refrigerant  
equipment  
Refrigerant (4)  
Heat exchanger  
Refrigerant control  
Deice control  
Fan type & Q'ty  
Motor  
Capillary tubes + Electronic expansion valve  
Microcomputer control  
Tangential fan x 1  
27  
Propeller fan x 1  
24  
Cooling  
Heating  
Hi : 11.5 Me : 8.0 Lo : 5.0  
Hi : 12.0 Me : 9.5 Lo : 7.0  
Not possible  
29.5  
Air handling  
equipment  
Air flow  
CMM  
27.0  
Fresh air intake  
Air filter, Quality / Quantity  
Polypropylene net (washable) x 2  
Shock & vibration absorber  
Electric heater  
Cushion rubber (for compressor)  
Operation switch  
Wireless-Remote control  
Microcomputer thermostat  
Operation  
control  
Room temperature control  
RUN : Green, TIMER : Yellow, HI POWER : Green,  
Operation Display  
3D AUTO : Green, ECONO : Blue  
Compressor overheat protection, Overcurrent protection,  
Safety devices  
Frost protection, Serial signal error protection, Indoor fan motor error protection,  
Heating overload protection (High pressure control), Cooling overload protection  
Refrigerant piping size (O.D)  
Connecting method  
mm  
m
Liquid line : 6.35 (1/4") Gas line : 9.52 (3/8")  
φ
φ
Flare connecting  
Liquid line : 0.55  
Gas line : 0.49  
Attached length of piping  
Installation  
data  
Insulation for piping  
Necessary (Both sides), independent  
Max. 15  
Refrigerant line (one way) length  
m
A
Vertical height difference between  
outdoor unit and indoor unit  
Max. 10 (Outdoor unit is higher)  
Max. 10 (Outdoor unit is lower)  
Drain hose  
Connectable (VP16)  
Power cable  
Recommended breaker size  
16  
Size x Core number  
Connecting method  
1.5mm2 x 4 cores (Including earth cable)  
Terminal block (Screw fixing type)  
Connection wiring  
Accessories (included)  
Optional parts  
Mounting kit, Clean filter (Allergen clear filter x 1, Photocatalytic washable deodorizing filter x 1)  
Interface kit (SC-BIKN-E)  
The pipe length is 7.5m.  
Note (1) The data are measured at the following conditions.  
Item  
Indoor air temperature  
Outdoor air temperature  
Standards  
DB  
WB  
19˚C  
DB  
35˚C  
7˚C  
WB  
24˚C  
6˚C  
Operation  
Cooling  
Heating  
27˚C  
20˚C  
ISO-T1, JIS C 9612  
(2) This air-conditioner is manufactured and tested in conformity with the ISO.  
(3) The operation data are applied to the 220/230/240V districts respectively.  
(4) The refrigerant quantity to be charged includes the refrigerant in 15m connecting piping.  
(Purging is not required even for the short piping.)  
RWA000Z229  
B
'10 • SR-T-091D  
Adapted to RoHS directive  
SRK25ZJX-S  
Model  
Item  
Indoor unit SRK25ZJX-S  
2550 (900 (Min.)  
3130 (900 (Min.)  
1 Phase, 220  
0.49 (0.19  
0.595 (0.23  
Outdoor unit SRC25ZJX-S  
Cooling capacity (1)  
Heating capacity (1)  
Power supply  
W
W
~
~
~
~
3200 (Max.))  
4700 (Max.))  
240 V, 50Hz  
0.82)  
1.12)  
Cooling  
Heating  
Cooling  
Heating  
Power  
consumption  
kW  
A
~
2.5 / 2.4 / 2.3 (220/ 230/ 240 V)  
3.1 / 2.9 / 2.8 (220/ 230/ 240 V)  
3.1 / 2.9 / 2.8 (220/ 230/ 240 V)  
5.20  
Running  
current  
Inrush current  
Operation  
data (1)  
Cooling  
COP  
Heating  
5.26  
Sound level  
Power level  
Sound level  
Power level  
dB(A)  
dB  
Hi : 41 Me : 31 Lo : 22  
47  
Cooling  
Heating  
55  
Hi : 41 Me : 34 Lo : 27  
58  
60  
Noise  
level  
dB(A)  
dB  
47  
60  
Exterior dimensions (Height x Width x Depth)  
mm  
309 x 890 x 220  
595 x 780 (+62) x 290  
Exterior appearance  
(Munsell color)  
Fine snow  
( 8.0Y 9.3/0.1 ) near equivalent  
Stucco white  
( 4.2Y 7.5/1.1 ) near equivalent  
Net weight  
kg  
kW  
kg  
15  
38  
Compressor type & Q'ty  
Motor (Starting method)  
RM-B5077MDE1 (Rotary type) x 1  
0.75 (Line starting)  
Refrigerant oil  
0.35 (DIAMOND FREEZE MA68)  
R410A 1.2 (Pre-Charged up to the piping length of 15m)  
Louver fins & inner grooved tubing M fins & inner grooved tubing  
Refrigerant  
equipment  
Refrigerant (4)  
Heat exchanger  
Refrigerant control  
Deice control  
Fan type & Q'ty  
Motor  
Capillary tubes + Electronic expansion valve  
Microcomputer control  
Tangential fan x 1  
27  
Propeller fan x 1  
24  
W
Cooling  
Heating  
Hi : 12.5 Me : 9.0 Lo : 5.0  
Hi : 13.0 Me : 10.0 Lo : 7.5  
Not possible  
29.5  
Air handling  
equipment  
Air flow  
CMM  
27.0  
Fresh air intake  
Air filter, Quality / Quantity  
Polypropylene net (washable) x 2  
Shock & vibration absorber  
Electric heater  
Cushion rubber (for compressor)  
Operation switch  
Wireless-Remote control  
Microcomputer thermostat  
Operation  
control  
Room temperature control  
RUN : Green, TIMER : Yellow, HI POWER : Green,  
Operation Display  
3D AUTO : Green, ECONO : Blue  
Compressor overheat protection, Overcurrent protection,  
Safety devices  
Frost protection, Serial signal error protection, Indoor fan motor error protection,  
Heating overload protection (High pressure control), Cooling overload protection  
Refrigerant piping size (O.D)  
Connecting method  
mm  
m
Liquid line : 6.35 (1/4") Gas line : 9.52 (3/8")  
φ
φ
Flare connecting  
Liquid line : 0.55  
Gas line : 0.49  
Attached length of piping  
Installation  
data  
Insulation for piping  
Necessary (Both sides), independent  
Max. 15  
Refrigerant line (one way) length  
m
A
Vertical height difference between  
outdoor unit and indoor unit  
Max. 10 (Outdoor unit is higher)  
Max. 10 (Outdoor unit is lower)  
Drain hose  
Connectable (VP16)  
Power cable  
Recommended breaker size  
16  
Size x Core number  
Connecting method  
1.5mm2 x 4 cores (Including earth cable)  
Terminal block (Screw fixing type)  
Connection wiring  
Accessories (included)  
Optional parts  
Mounting kit, Clean filter (Allergen clear filter x 1, Photocatalytic washable deodorizing filter x 1)  
Interface kit (SC-BIKN-E)  
The pipe length is 7.5m.  
Note (1) The data are measured at the following conditions.  
Item  
Indoor air temperature  
Outdoor air temperature  
Standards  
DB  
WB  
19˚C  
DB  
35˚C  
7˚C  
WB  
24˚C  
6˚C  
Operation  
Cooling  
Heating  
27˚C  
20˚C  
ISO-T1, JIS C 9612  
(2) This air-conditioner is manufactured and tested in conformity with the ISO.  
(3) The operation data are applied to the 220/230/240V districts respectively.  
(4) The refrigerant quantity to be charged includes the refrigerant in 15m connecting piping.  
(Purging is not required even for the short piping.)  
RWA000Z229  
B
'10 • SR-T-091D  
Adapted to RoHS directive  
SRK35ZJX-S  
Model  
Item  
Indoor unit SRK35ZJX-S  
3500 (900 (Min.)  
4300 (900 (Min.)  
1 Phase, 220  
Outdoor unit SRC35ZJX-S  
Cooling capacity (1)  
Heating capacity (1)  
Power supply  
W
W
~
~
~
4100 (Max.))  
5100 (Max.))  
240 V, 50Hz  
Cooling  
Heating  
Cooling  
Heating  
0.845 (0.19  
~
1.35)  
1.01)  
Power  
consumption  
kW  
A
0.960 (0.23  
~
4.0 / 3.8 / 3.6 (220/ 230/ 240 V)  
4.6 / 4.4 / 4.2 (220/ 230/ 240 V)  
4.6 / 4.4 / 4.2 (220/ 230/ 240 V)  
4.14  
Running  
current  
Inrush current  
Operation  
data (1)  
Cooling  
COP  
Heating  
4.48  
Sound level  
Power level  
Sound level  
Power level  
dB(A)  
dB  
Hi : 43 Me : 33 Lo : 22  
50  
Cooling  
Heating  
58  
Hi : 42 Me : 35 Lo : 27  
59  
63  
Noise  
level  
dB(A)  
dB  
50  
62  
Exterior dimensions (Height x Width x Depth)  
mm  
309 x 890 x 220  
595 x 780 (+62) x 290  
Exterior appearance  
(Munsell color)  
Fine snow  
( 8.0Y 9.3/0.1 ) near equivalent  
Stucco white  
( 4.2Y 7.5/1.1 ) near equivalent  
Net weight  
kg  
kW  
kg  
15  
38  
Compressor type & Q'ty  
Motor (Starting method)  
RM-B5077MDE1 (Rotary type) x 1  
0.90 (Line starting)  
Refrigerant oil  
0.35 (DIAMOND FREEZE MA68)  
R410A 1.2 (Pre-Charged up to the piping length of 15m)  
Louver fins & inner grooved tubing M fins & inner grooved tubing  
Refrigerant  
equipment  
Refrigerant (4)  
Heat exchanger  
Refrigerant control  
Deice control  
Fan type & Q'ty  
Motor  
Capillary tubes + Electronic expansion valve  
Microcomputer control  
Tangential fan x 1  
27  
Propeller fan x 1  
24  
W
Cooling  
Heating  
Hi : 13.5 Me : 9.5 Lo : 5.0  
Hi : 14.0 Me : 11.0 Lo : 8.0  
Not possible  
32.5  
Air handling  
equipment  
Air flow  
CMM  
29.5  
Fresh air intake  
Air filter, Quality / Quantity  
Polypropylene net (washable) x 2  
Shock & vibration absorber  
Electric heater  
Cushion rubber (for compressor)  
Operation switch  
Wireless-Remote control  
Microcomputer thermostat  
Operation  
control  
Room temperature control  
RUN : Green, TIMER : Yellow, HI POWER : Green,  
Operation Display  
3D AUTO : Green, ECONO : Blue  
Compressor overheat protection, Overcurrent protection,  
Safety devices  
Frost protection, Serial signal error protection, Indoor fan motor error protection,  
Heating overload protection (High pressure control), Cooling overload protection  
Refrigerant piping size (O.D)  
Connecting method  
mm  
m
Liquid line : 6.35 (1/4") Gas line : 9.52 (3/8")  
φ
φ
Flare connecting  
Liquid line : 0.55  
Gas line : 0.49  
Attached length of piping  
Installation  
data  
Insulation for piping  
Necessary (Both sides), independent  
Max. 15  
Refrigerant line (one way) length  
m
A
Vertical height difference between  
outdoor unit and indoor unit  
Max. 10 (Outdoor unit is higher)  
Max. 10 (Outdoor unit is lower)  
Drain hose  
Connectable (VP16)  
Power cable  
Recommended breaker size  
16  
Size x Core number  
Connecting method  
1.5mm2 x 4 cores (Including earth cable)  
Terminal block (Screw fixing type)  
Connection wiring  
Accessories (included)  
Optional parts  
Mounting kit, Clean filter (Allergen clear filter x 1, Photocatalytic washable deodorizing filter x 1)  
Interface kit (SC-BIKN-E)  
The pipe length is 7.5m.  
Note (1) The data are measured at the following conditions.  
Item  
Indoor air temperature  
Outdoor air temperature  
Standards  
DB  
WB  
19˚C  
DB  
35˚C  
7˚C  
WB  
24˚C  
6˚C  
Operation  
Cooling  
Heating  
27˚C  
20˚C  
ISO-T1, JIS C 9612  
(2) This air-conditioner is manufactured and tested in conformity with the ISO.  
(3) The operation data are applied to the 220/230/240V districts respectively.  
(4) The refrigerant quantity to be charged includes the refrigerant in 15m connecting piping.  
(Purging is not required even for the short piping.)  
RWA000Z229  
B
'10 • SR-T-091D  
Adapted to RoHS directive  
SRK50ZJX-S  
Model  
Item  
Indoor unit SRK50ZJX-S  
5000 (700 (Min.)  
6000 (700 (Min.)  
1 Phase, 220  
Outdoor unit SRC50ZIX-S  
Cooling capacity (1)  
Heating capacity (1)  
Power supply  
W
W
~
~
~
6200 (Max.))  
8800 (Max.))  
240 V, 50Hz  
Cooling  
Heating  
Cooling  
Heating  
1.30 (0.2  
~
2.26)  
2.20)  
Power  
consumption  
kW  
A
1.35 (0.2~  
6.0 / 5.7 / 5.5 (220/ 230/ 240 V)  
6.2 / 5.9 / 5.7 (220/ 230/ 240 V)  
6.2 / 5.9 / 5.7 (220/ 230/ 240 V)  
3.85  
Running  
current  
Inrush current  
Operation  
data (1)  
Cooling  
COP  
Heating  
4.44  
Sound level  
Power level  
Sound level  
Power level  
dB(A)  
dB  
Hi : 45 Me : 38 Lo : 26  
48  
Cooling  
Heating  
60  
Hi : 45 Me : 38 Lo : 32  
62  
62  
Noise  
level  
dB(A)  
dB  
48  
62  
Exterior dimensions (Height x Width x Depth)  
mm  
309 x 890 x 220  
640 x 800 (+71) x 290  
Exterior appearance  
(Munsell color)  
Fine snow  
( 8.0Y 9.3/0.1 ) near equivalent  
Stucco white  
( 4.2Y 7.5/1.1 ) near equivalent  
Net weight  
kg  
kW  
kg  
15  
43  
Compressor type & Q'ty  
Motor (Starting method)  
5CS130XGB04 (Scroll type) x 1  
0.9 (Line starting)  
Refrigerant oil  
0.48 (RB68A or Freol Alpha 68M)  
R410A 1.4 (Pre-Charged up to the piping length of 15m)  
Louver fins & inner grooved tubing M fins & inner grooved tubing  
Refrigerant  
equipment  
Refrigerant (3)  
Heat exchanger  
Refrigerant control  
Deice control  
Fan type & Q'ty  
Motor  
Capillary tubes + Electronic expansion valve  
Microcomputer control  
Tangential fan x 1  
27  
Propeller fan x 1  
34  
W
Cooling  
Heating  
Hi : 13.5 Me : 11 Lo: 8  
Hi : 16.5 Me : 14.5 Lo : 10.5  
Not possible  
36.0  
Air handling  
equipment  
Air flow  
CMM  
33.0  
Fresh air intake  
Air filter, Quality / Quantity  
Polypropylene net (washable) x 2  
Shock & vibration absorber  
Electric heater  
Cushion rubber (for compressor)  
Operation switch  
Wireless-Remote control  
Microcomputer thermostat  
Operation  
control  
Room temperature control  
RUN : Green, TIMER : Yellow, HI POWER : Green,  
Operation Display  
3D AUTO : Green, ECONO : Blue  
Compressor overheat protection, Overcurrent protection,  
Safety devices  
Frost protection, Serial signal error protection, Indoor fan motor error protection,  
Heating overload protection (High pressure control), Cooling overload protection  
Refrigerant piping size (O.D)  
Connecting method  
mm  
m
Liquid line : 6.35 (1/4") Gas line : 12.7 (1/2")  
φ
φ
Flare connecting  
Liquid line : 0.55  
Gas line : 0.49  
Attached length of piping  
Installation  
data  
Insulation for piping  
Necessary (Both sides), independent  
Max. 30  
Refrigerant line (one way) length  
m
A
Vertical height difference between  
outdoor unit and indoor unit  
Max. 20 (Outdoor unit is higher)  
Max. 20 (Outdoor unit is lower)  
Drain hose  
Connectable (VP16)  
Power cable  
Recommended breaker size  
16  
Size x Core number  
Connecting method  
1.5mm2 x 4 cores (Including earth cable)  
Terminal block (Screw fixing type)  
Connection wiring  
Accessories (included)  
Optional parts  
Mounting kit, Clean filter (Allergen clear filter x 1, Photocatalytic washable deodorizing filter x 1)  
Interface kit (SC-BIKN-E)  
The pipe length is 7.5m.  
Note (1) The data are measured at the following conditions.  
Item  
Indoor air temperature  
Outdoor air temperature  
Standards  
DB  
WB  
19˚C  
DB  
35˚C  
7˚C  
WB  
24˚C  
6˚C  
Operation  
Cooling  
Heating  
27˚C  
20˚C  
ISO-T1, JIS C 9612  
(2) This air-conditioner is manufactured and tested in conformity with the ISO.  
(3) The operation data are applied to the 220/230/240V districts respectively.  
(4) The refrigerant quantity to be charged includes the refrigerant in 15m connecting piping.  
(Purging is not required even for the short piping.)  
RWA000Z229  
B
'10 • SR-T-091D  
Adapted to RoHS directive  
SRK60ZJX-S  
Model  
Item  
Indoor unit SRK60ZJX-S  
6000 (800 (Min.)  
6800 (800 (Min.)  
1 Phase, 220  
Outdoor unit SRC60ZIX-S  
Cooling capacity (1)  
Heating capacity (1)  
Power supply  
W
W
~
~
~
6800 (Max.))  
9700 (Max.))  
240 V, 50Hz  
Cooling  
Heating  
Cooling  
Heating  
1.86 (0.25  
~
2.70)  
2.30)  
Power  
consumption  
kW  
A
1.67 (0.25~  
8.5 / 8.2 / 7.8 (220/ 230/ 240 V)  
7.7 / 7.3 / 7.0 (220/ 230/ 240 V)  
8.5 / 8.2 / 7.8 (220/ 230/ 240 V)  
3.23  
Running  
current  
Inrush current  
Operation  
data (1)  
Cooling  
COP  
Heating  
4.07  
Sound level  
Power level  
Sound level  
Power level  
dB(A)  
dB  
Hi : 47 Me : 38 Lo : 26  
51  
Cooling  
Heating  
62  
Hi : 45 Me : 39 Lo : 33  
62  
65  
Noise  
level  
dB(A)  
dB  
51  
65  
Exterior dimensions (Height x Width x Depth)  
mm  
309 x 890 x 220  
640 x 800 (+71) x 290  
Exterior appearance  
(Munsell color)  
Fine snow  
( 8.0Y 9.3/0.1 ) near equivalent  
Stucco white  
( 4.2Y 7.5/1.1 ) near equivalent  
Net weight  
kg  
kW  
kg  
15  
43  
Compressor type & Q'ty  
Motor (Starting method)  
5CS130XGB04 (Scroll type) x 1  
0.9 (Line starting)  
Refrigerant oil  
0.48 (RB68A or Freol Alpha 68M)  
R410A 1.4 (Pre-Charged up to the piping length of 15m)  
Louver fins & inner grooved tubing M fins & inner grooved tubing  
Refrigerant  
equipment  
Refrigerant (3)  
Heat exchanger  
Refrigerant control  
Deice control  
Fan type & Q'ty  
Motor  
Capillary tubes + Electronic expansion valve  
Microcomputer control  
Tangential fan x 1  
27  
Propeller fan x 1  
34  
W
Cooling  
Heating  
Hi : 14.5 Me : 12.5 Lo : 8.5  
Hi : 17.0 Me : 15.0 Lo : 11.0  
Not possible  
41.5  
Air handling  
equipment  
Air flow  
CMM  
36.0  
Fresh air intake  
Air filter, Quality / Quantity  
Polypropylene net (washable) x 2  
Shock & vibration absorber  
Electric heater  
Cushion rubber (for compressor)  
Operation switch  
Wireless-Remote control  
Microcomputer thermostat  
Operation  
control  
Room temperature control  
RUN : Green, TIMER : Yellow, HI POWER : Green,  
Operation Display  
3D AUTO : Green, ECONO : Blue  
Compressor overheat protection, Overcurrent protection,  
Safety devices  
Frost protection, Serial signal error protection, Indoor fan motor error protection,  
Heating overload protection (High pressure control), Cooling overload protection  
Refrigerant piping size (O.D)  
Connecting method  
mm  
m
Liquid line : 6.35 (1/4") Gas line : 12.7 (1/2")  
φ
φ
Flare connecting  
Liquid line : 0.55  
Gas line : 0.49  
Attached length of piping  
Installation  
data  
Insulation for piping  
Necessary (Both sides), independent  
Max. 30  
Refrigerant line (one way) length  
m
A
Vertical height difference between  
outdoor unit and indoor unit  
Max. 20 (Outdoor unit is higher)  
Max.20 (Outdoor unit is lower)  
Drain hose  
Connectable (VP 16)  
Power cable  
Recommended breaker size  
16  
Size x Core number  
Connecting method  
1.5mm2 x 4 cores (Including earth cable)  
Terminal block (Screw fixing type)  
Connection wiring  
Accessories (included)  
Optional parts  
Mounting kit, Clean filter (Allergen clear filter x 1, Photocatalytic washable deodorizing filter x 1)  
Interface kit (SC-BIKN-E)  
The pipe length is 7.5m.  
Note (1) The data are measured at the following conditions.  
Item  
Indoor air temperature  
Outdoor air temperature  
Standards  
DB  
WB  
19˚C  
DB  
35˚C  
7˚C  
WB  
24˚C  
6˚C  
Operation  
Cooling  
Heating  
27˚C  
20˚C  
ISO-T1, JIS C 9612  
(2) This air-conditioner is manufactured and tested in conformity with the ISO.  
(3) The operation data are applied to the 220/230/240V districts respectively.  
(4) The refrigerant quantity to be charged includes the refrigerant in 15m connecting piping.  
(Purging is not required even for the short piping.)  
RWA000Z229  
B
'10 • SR-T-091D  
(2) Floor standing type (SRF)  
Adapted to RoHS directive  
SRF25ZJX-S  
Model  
Item  
Indoor unit SRF25ZJX-S  
2500 (900 (Min.)  
3400 (900 (Min.)  
1 Phase, 220  
Outdoor unit SRC25ZJX-S  
Cooling capacity (1)  
Heating capacity (1)  
Power supply  
W
W
~
~
~
3200 (Max.))  
4700 (Max.))  
240 V, 50Hz  
Cooling  
Heating  
Cooling  
Heating  
0.521 (0.19  
~
1.20)  
0.82)  
Power  
consumption  
kW  
A
0.723 (0.23  
~
2.6 / 2.5 / 2.4 (220/ 230/ 240 V)  
3.6 / 3.4 / 3.3 (220/ 230/ 240 V)  
3.6 / 3.4 / 3.3 (220/ 230/ 240 V)  
4.80  
Running  
current  
Inrush current  
Operation  
data (1)  
Cooling  
COP  
Heating  
4.70  
Sound level  
Power level  
Sound level  
Power level  
dB(A)  
dB  
Hi : 40 Me : 32 Lo : 26  
47  
Cooling  
Heating  
51  
Hi : 40 Me : 35 Lo : 28  
51  
60  
Noise  
level  
dB(A)  
dB  
47  
60  
Exterior dimensions (Height x Width x Depth)  
mm  
600 x 860 x 238  
595 x 780 x 290  
Exterior appearance  
( Munsell color )  
Fine snow  
( 8.0Y 9.3/0.1 ) near equivalent  
Stucco white  
( 4.2Y 7.5/1.1 ) near equivalent  
Net weight  
kg  
kW  
kg  
18  
38  
Compressor type & Q'ty  
Motor (Starting method)  
RM-B5077MDE1 (Rotary type) x 1  
0.75 (Line starting)  
Refrigerant oil  
0.35 (DIAMOND FREEZE MA68)  
R410A 1.2 (Pre-Charged up to the piping length of 15m)  
Louver fins & inner grooved tubing M fins & inner grooved tubing  
Refrigerant  
equipment  
Refrigerant (3)  
Heat exchanger  
Refrigerant control  
Deice control  
Fan type & Q'ty  
Motor  
Capillary tubes + Electronic expansion valve  
Microcomputer control  
Turbo fan x 1  
40  
Propeller fan x 1  
24  
W
Cooling  
Heating  
Hi : 9.0 Me : 7.6 Lo : 5.8  
Hi : 10.5 Me : 8.2 Lo : 6.6  
Impossible  
29.5  
Air handling  
equipment  
Air flow  
CMM  
27.0  
Fresh air intake  
Air filter, Quality / Quantity  
Polypropylene net (washable) x 1  
Shock & vibration absorber  
Electric heater  
Cushion rubber (for compressor)  
Operation switch  
Wireless-Remote control  
Microcomputer thermostat  
Operation  
control  
Room temperature control  
RUN : Green, TIMER : Yellow, HI POWER : Green,  
AIR OUTLET SELECTION : Green, ECONO : Green  
Operation Display  
Compressor overheat protection, Overcurrent protection,  
Safety devices  
Frost protection, Serial signal error protection, Indoor fan motor error protection,  
Heating overload protection (High pressure control), Cooling overload protection  
Refrigerant piping size (O.D)  
Connecting method  
mm  
m
Liquid line : 6.35 (1/4") Gas line : 9.52 (3/8")  
φ
φ
Flare connecting  
Attached length of piping  
Installation  
data  
Insulation for piping  
Necessary (Both sides), independent  
Max. 15  
Refrigerant line (one way) length  
m
A
Vertical height difference between  
outdoor unit and indoor unit  
Max. 10 (Outdoor unit is higher)  
Max. 10 (Outdoor unit is lower)  
Drain hose  
Connectable (VP16)  
Power cable  
Recommended breaker size  
16  
Size x Core number  
Connecting method  
1.5mm2 x 4 cores (Including earth cable)  
Terminal block (Screw fixing type)  
Connection wiring  
Accessories (included)  
Optional parts  
Mounting kit, Clean filter (Natural enzyme filter x 1, Photocatalytic washable deodorizing filter x 1)  
Interface kit (SC-BIKN-E)  
The pipe length is 7.5m.  
Note (1) The data are measured at the following conditions.  
Item  
Indoor air temperature  
Outdoor air temperature  
Standards  
DB  
WB  
19˚C  
DB  
35˚C  
7˚C  
WB  
24˚C  
6˚C  
Operation  
Cooling  
Heating  
27˚C  
20˚C  
ISO-T1, JIS C 9612  
(2) This air-conditioner is manufactured and tested in conformity with the ISO.  
(3) The operation data are applied to the 220/230/240V districts respectively.  
(4) The refrigerant quantity to be charged includes the refrigerant in 15m connecting piping.  
(Purging is not required even for the short piping.)  
RWB000Z053  
A
'10 • SR-T-091D  
Adapted to RoHS directive  
SRF35ZJX-S  
Model  
Item  
Indoor unit SRF35ZJX-S  
3500 (900 (Min.)  
4500 (900 (Min.)  
1 Phase, 220  
Outdoor unit SRC35ZJX-S  
Cooling capacity (1)  
Heating capacity (1)  
Power supply  
W
W
~
~
~
4100 (Max.))  
5100 (Max.))  
240 V, 50Hz  
Cooling  
Heating  
Cooling  
Heating  
0.890 (0.19  
~
1.43)  
1.26)  
Power  
consumption  
kW  
A
1.124 (0.23  
~
4.1 / 3.9 / 3.7 (220/ 230/ 240 V)  
5.2 / 4.9 / 4.7 (220/ 230/ 240 V)  
5.2 / 4.9 / 4.7 (220/ 230/ 240 V)  
3.93  
Running  
current  
Inrush current  
Operation  
data (1)  
Cooling  
COP  
Heating  
4.00  
Sound level  
Power level  
Sound level  
Power level  
dB(A)  
dB  
Hi : 41 Me : 34 Lo : 28  
50  
Cooling  
Heating  
52  
Hi : 41 Me : 36 Lo : 31  
52  
63  
Noise  
level  
dB(A)  
dB  
50  
62  
Exterior dimensions (Height x Width x Depth)  
mm  
600 x 860 x 238  
595 x 780 x 290  
Exterior appearance  
( Munsell color )  
Fine snow  
( 8.0Y 9.3/0.1 ) near equivalent  
Stucco white  
( 4.2Y 7.5/1.1 ) near equivalent  
Net weight  
kg  
kW  
kg  
19  
38  
Compressor type & Q'ty  
Motor (Starting method)  
RM-B5077MDE1 (Rotary type) x 1  
0.90 (Line starting)  
Refrigerant oil  
0.35 (DIAMOND FREEZE MA68)  
R410A 1.2 (Pre-Charged up to the piping length of 15m)  
Louver fins & inner grooved tubing M fins & inner grooved tubing  
Refrigerant  
equipment  
Refrigerant (3)  
Heat exchanger  
Refrigerant control  
Deice control  
Fan type & Q'ty  
Motor  
Capillary tubes + Electronic expansion valve  
Microcomputer control  
Turbo fan x 1  
40  
Propeller fan x 1  
24  
W
Cooling  
Heating  
Hi : 9.2 Me : 7.8 Lo : 6.4  
Hi : 10.7 Me : 8.3 Lo : 7.4  
Impossible  
32.5  
Air handling  
equipment  
Air flow  
CMM  
29.5  
Fresh air intake  
Air filter, Quality / Quantity  
Polypropylene net (washable) x 1  
Shock & vibration absorber  
Electric heater  
Cushion rubber (for compressor)  
Operation switch  
Wireless-Remote control  
Microcomputer thermostat  
Operation  
control  
Room temperature control  
RUN : Green, TIMER : Yellow, HI POWER : Green,  
AIR OUTLET SELECTION : Green, ECONO : Green  
Operation Display  
Compressor overheat protection, Overcurrent protection,  
Safety devices  
Frost protection, Serial signal error protection, Indoor fan motor error protection,  
Heating overload protection (High pressure control), Cooling overload protection  
Refrigerant piping size (O.D)  
Connecting method  
mm  
m
Liquid line : 6.35 (1/4") Gas line : 9.52 (3/8")  
φ
φ
Flare connecting  
Attached length of piping  
Installation  
data  
Insulation for piping  
Necessary (Both sides), independent  
Max. 15  
Refrigerant line (one way) length  
m
A
Vertical height difference between  
outdoor unit and indoor unit  
Max. 10 (Outdoor unit is higher)  
Max.10 (Outdoor unit is lower)  
Drain hose  
Connectable (VP16)  
Power cable  
Recommended breaker size  
16  
Size x Core number  
Connecting method  
1.5mm2 x 4 cores (Including earth cable)  
Terminal block (Screw fixing type)  
Connection wiring  
Accessories (included)  
Optional parts  
Mounting kit, Clean filter (Natural enzyme filter x 1, Photocatalytic washable deodorizing filter x 1)  
Interface kit (SC-BIKN-E)  
The pipe length is 7.5m.  
Note (1) The data are measured at the following conditions.  
Item  
Indoor air temperature  
Outdoor air temperature  
Standards  
DB  
WB  
19˚C  
DB  
35˚C  
7˚C  
WB  
24˚C  
6˚C  
Operation  
Cooling  
Heating  
27˚C  
20˚C  
ISO-T1, JIS C 9612  
(2) This air-conditioner is manufactured and tested in conformity with the ISO.  
(3) The operation data are applied to the 220/230/240V districts respectively.  
(4) The refrigerant quantity to be charged includes the refrigerant in 15m connecting piping.  
(Purging is not required even for the short piping.)  
RWB000Z053  
A
'10 • SR-T-091D  
Adapted to RoHS directive  
SRF50ZJX-S  
Model  
Item  
Indoor unit SRF50ZJX-S  
5000 (700 (Min.)  
6000 (700 (Min.)  
1 Phase, 220  
Outdoor unit SRC50ZIX-S  
Cooling capacity (1)  
Heating capacity (1)  
Power supply  
W
W
~
~
~
5500 (Max.))  
7000 (Max.))  
240 V, 50Hz  
Cooling  
Heating  
Cooling  
Heating  
1.390 (0.2  
~
2.25)  
1.80)  
Power  
consumption  
kW  
A
1.540 (0.2~  
6.4 / 6.1 / 5.8 (220/ 230/ 240 V)  
7.1 / 6.8 / 6.5 (220/ 230/ 240 V)  
7.1 / 6.8 / 6.5 (220/ 230/ 240 V)  
3.60  
Running  
current  
Inrush current  
Operation  
data (1)  
Cooling  
COP  
Heating  
3.90  
Sound level  
Power level  
Sound level  
Power level  
dB(A)  
dB  
Hi : 47 Me : 39 Lo : 30  
48  
Cooling  
Heating  
58  
Hi : 47 Me : 39 Lo : 32  
58  
62  
Noise  
level  
dB(A)  
dB  
48  
62  
Exterior dimensions (Height x Width x Depth)  
mm  
600 x 860 x 238  
640 x 800 x 290  
Exterior appearance  
(Munsell color)  
Fine snow  
( 8.0Y 9.3/0.1 ) near equivalent  
Stucco white  
( 4.2Y 7.5/1.1 ) near equivalent  
Net weight  
kg  
kW  
kg  
19  
43  
Compressor type & Q'ty  
Motor (Starting method)  
5CS130XGB04 (Scroll type) x 1  
0.9 (Line starting)  
Refrigerant oil  
0.48 (RB68A or Freol Alpha 68M)  
R410A 1.4 (Pre-Charged up to the piping length of 15m)  
Louver fins & inner grooved tubing M fins & inner grooved tubing  
Refrigerant  
equipment  
Refrigerant (3)  
Heat exchanger  
Refrigerant control  
Deice control  
Fan type & Q'ty  
Motor  
Capillary tubes + Electronic expansion valve  
Microcomputer control  
Turbo fan x 1  
40  
Propeller fan x 1  
34  
W
Cooling  
Heating  
Hi : 11.5 Me : 9.6 Lo : 6.6  
Hi : 12.0 Me : 10.0 Lo : 7.6  
Impossible  
36.0  
Air handling  
equipment  
Air flow  
CMM  
33.0  
Fresh air intake  
Air filter, Quality / Quantity  
Polypropylene net (washable) x 1  
Shock & vibration absorber  
Electric heater  
Cushion rubber (for compressor)  
Operation switch  
Wireless-Remote control  
Microcomputer thermostat  
Operation  
control  
Room temperature control  
RUN : Green, TIMER : Yellow, HI POWER : Green,  
AIR OUTLET SELECTION : Green, ECONO : Green  
Operation Display  
Compressor overheat protection, Overcurrent protection,  
Safety devices  
Frost protection, Serial signal error protection, Indoor fan motor error protection,  
Heating overload protection (High pressure control), Cooling overload protection  
Refrigerant piping size (O.D)  
Connecting method  
mm  
m
Liquid line : 6.35 (1/4") Gas line : 12.7 (1/2")  
φ
φ
Flare connecting  
Attached length of piping  
Installation  
data  
Insulation for piping  
Necessary (Both sides), independent  
Max. 30  
Refrigerant line (one way) length  
m
A
Vertical height difference between  
outdoor unit and indoor unit  
Max. 20 (Outdoor unit is higher)  
Max. 20 (Outdoor unit is lower)  
Drain hose  
Connectable (VP16)  
Power cable  
Recommended breaker size  
16  
Size x Core number  
Connecting method  
1.5mm2 x 4 cores (Including earth cable)  
Terminal block (Screw fixing type)  
Connection wiring  
Accessories (included)  
Optional parts  
Mounting kit, Clean filter (Natural enzyme filter x 1, Photocatalytic washable deodorizing filter x 1)  
Interface kit (SC-BIKN-E)  
The pipe length is 7.5m.  
Note (1) The data are measured at the following conditions.  
Item  
Indoor air temperature  
Outdoor air temperature  
Standards  
DB  
WB  
19˚C  
DB  
35˚C  
7˚C  
WB  
24˚C  
6˚C  
Operation  
Cooling  
Heating  
27˚C  
20˚C  
ISO-T1, JIS C 9612  
(2) This air-conditioner is manufactured and tested in conformity with the ISO.  
(3) The operation data are applied to the 220/230/240V districts respectively.  
(4) The refrigerant quantity to be charged includes the refrigerant in 15m connecting piping.  
(Purging is not required even for the short piping.)  
RWB000Z053  
A
ꢀ0  
'10 • SR-T-091D  
(3) Ceiling concealed type (SRR)  
Adapted to RoHS directive  
SRR25ZJ-S  
Model  
Item  
Indoor unit SRR25ZJ-S  
2500 ( 900 (Min.)  
3400 ( 900 (Min.)  
1 Phase, 220  
Outdoor unit SRC25ZJX-S  
Cooling capacity (1)  
Heating capacity (1)  
Power supply  
W
W
~
~
~
3200 (Max.))  
4700 (Max.))  
240 V, 50Hz  
Cooling  
Heating  
Cooling  
Heating  
0.580 ( 0.19  
~
1.20 )  
0.82 )  
Power  
consumption  
kW  
A
0.750 ( 0.23  
~
2.9 / 2.8 / 2.7 (220/ 230/ 240 V)  
3.7 / 3.6 / 3.4 (220/ 230/ 240 V)  
3.7 / 3.6 / 3.4 (220/ 230/ 240 V)  
4.31  
Running  
current  
Inrush current  
Operation  
data (1)  
Cooling  
COP  
Heating  
4.53  
Sound level  
Power level  
Sound level  
Power level  
dB(A)  
dB  
Hi : 40 Me : 35 Lo : 29  
47  
Cooling  
Heating  
54  
Hi: 41 Me: 38 Lo: 31  
55  
60  
Noise  
level  
dB(A)  
dB  
47  
60  
Exterior dimensions (Height x Width x Depth)  
mm  
230 x 740 x 455  
595 x 780 x 290  
Exterior appearance  
(Munsell color)  
Stucco white  
( 4.2Y 7.5/1.1 ) near equivalent  
Net weight  
kg  
kW  
kg  
22  
38  
Compressor type & Q'ty  
Motor (Starting method)  
RM-B5077MDE1 (Rotary type) x 1  
0.75 (Line starting)  
Refrigerant oil  
0.35 (DIAMOND FREEZE MA68)  
R410A 1.2 ( Pre-Charged up to the piping length of 15m )  
Louver fins & inner grooved tubing M fins & inner grooved tubing  
Refrigerant  
equipment  
Refrigerant (3)  
Heat exchanger  
Refrigerant control  
Deice control  
Fan type & Q'ty  
Motor  
Capillary tubes + Electronic expansion valve  
Microcomputer control  
Centrifugal fan x 2  
51  
Propeller fan x 1  
24  
W
Cooling  
Heating  
Hi : 8.5 Me : 7.0 Lo : 5.0  
Hi : 10.0 Me : 9.0 Lo : 6.5  
Not possible  
29.5  
Air handling  
equipment  
Air flow  
CMM  
27.0  
Fresh air intake  
Air filter, Quality / Quantity  
Polypropylene net x 1  
Shock & vibration absorber  
Electric heater  
Cushion rubber (for compressor)  
Operation switch  
Wireless-Remote control  
Microcomputer thermostat  
Operation  
control  
Room temperature control  
RUN : Green, TIMER : Yellow,  
HI POWER : Green, ECONO : Green  
Operation Display  
Compressor overheat protection, Overcurrent protection, Drain error protection  
Frost protection, Serial signal error protection, Indoor fan motor error protection,  
Heating overload protection( High pressure control ), Cooling overload protection  
Safety devices  
Refrigerant piping size (O.D)  
Connecting method  
mm  
m
Liquid line : 6.35 (1/4") Gas line : 9.52 (3/8")  
φ
φ
Flare connecting  
Attached length of piping  
Installation  
data  
Insulation for piping  
Necessary (Both sides), independent  
Max. 15  
Refrigerant line (one way) length  
m
A
Vertical height difference between  
outdoor unit and indoor unit  
Max. 10 (Outdoor unit is higher)  
Max. 10 (Outdoor unit is lower)  
Drain hose  
Connectable (VP16)  
Power cable  
Recommended breaker size  
16  
Size x Core number  
Connecting method  
1.5mm2 x 4 cores (Including earth cable)  
Terminal block (Screw fixing type)  
Mounting kit  
Connection wiring  
Accessories (included)  
Optional parts  
Wired remote control, Interface kit (SC-BIKN-E)  
The pipe length is 7.5m.  
Note (1) The data are measured at the following conditions.  
Item  
Indoor air temperature  
Outdoor air temperature  
Standards  
DB  
WB  
19˚C  
DB  
35˚C  
7˚C  
WB  
24˚C  
6˚C  
Operation  
Cooling  
Heating  
27˚C  
20˚C  
ISO-T1, JIS C 9612  
(2) This air-conditioner is manufactured and tested in conformity with the ISO.  
(3) The operation data are applied to the 220/230/240V districts respectively.  
(4) The refrigerant quantity to be charged includes the refrigerant in 15m connecting piping.  
(Purging is not required even for the short piping.)  
RWA000Z231  
A
ꢀꢀ  
'10 • SR-T-091D  
Adapted to RoHS directive  
SRR35ZJ-S  
Model  
Item  
Indoor unit SRR35ZJ-S  
3500 ( 900 (Min.)  
4200 ( 900 (Min.)  
1 Phase, 220  
Outdoor unit SRC35ZJX-S  
Cooling capacity (1)  
Heating capacity (1)  
Power supply  
W
W
~
~
~
4100 (Max.))  
5100 (Max.))  
240 V, 50Hz  
Cooling  
Heating  
Cooling  
Heating  
1.080 ( 0.19  
~
1.43 )  
1.26 )  
Power  
consumption  
kW  
A
1.100 ( 0.23  
~
5.0 / 4.7 / 4.5 (220/ 230/ 240 V)  
5.1 / 4.8 / 4.6 (220/ 230/ 240 V)  
5.1 / 4.8 / 4.6 (220/ 230/ 240 V)  
3.24  
Running  
current  
Inrush current  
Operation  
data (1)  
Cooling  
COP  
Heating  
3.82  
Sound level  
Power level  
Sound level  
Power level  
dB(A)  
dB  
Hi: 42 Me : 37 Lo: 30  
50  
Cooling  
Heating  
56  
Hi : 43 Me : 40 Lo : 32  
57  
62  
Noise  
level  
dB(A)  
dB  
50  
62  
Exterior dimensions (Height x Width x Depth)  
mm  
230 x 740 x 455  
595 x 780 x 290  
Exterior appearance  
(Munsell color)  
Stucco white  
(4.2Y 7.5/1.1) near equivalent  
Net weight  
kg  
kW  
kg  
22  
38  
Compressor type & Q'ty  
Motor (Starting method)  
RM-B5077MDE1 (Rotary type) x 1  
0.75 ( Line starting )  
Refrigerant oil  
0.35 (DIAMOND FREEZE MA68)  
R410A 1.2 (Pre-Charged up to the piping length of 15m)  
Louver fins & inner grooved tubing M fins & inner grooved tubing  
Refrigerant  
equipment  
Refrigerant (3)  
Heat exchanger  
Refrigerant control  
Deice control  
Fan type & Q'ty  
Motor  
Capillary tubes + Electronic expansion valve  
Microcomputer control  
Centrifugal fan x 2  
51  
Propeller fan x 1  
24  
W
Cooling  
Heating  
Hi : 9.0 Me : 7.5 Lo : 5.5  
Hi : 11.0 Me : 9.5 Lo : 7.0  
Not possible  
32.5  
Air handling  
equipment  
Air flow  
CMM  
29.5  
Fresh air intake  
Air filter, Quality / Quantity  
Polypropylene net x 1  
Shock & vibration absorber  
Electric heater  
Cushion rubber (for compressor)  
Operation switch  
Wireless-Remote control  
Microcomputer thermostat  
Operation  
control  
Room temperature control  
RUN : Green, TIMER : Yellow,  
HI POWER : Green, ECONO : Green  
Operation Display  
Compressor overheat protection, Overcurrent protection, Drain error protection  
Frost protection, Serial signal error protection, Indoor fan motor error protection,  
Heating overload protection (High pressure control), Cooling overload protection  
Safety devices  
Refrigerant piping size (O.D)  
Connecting method  
mm  
m
Liquid line : 6.35 (1/4") Gas line : 9.52 (3/8")  
φ
φ
Flare connecting  
Attached length of piping  
Installation  
data  
Insulation for piping  
Necessary (Both sides), independent  
Max. 15  
Refrigerant line (one way) length  
m
A
Vertical height difference between  
outdoor unit and indoor unit  
Max. 10 (Outdoor unit is higher)  
Max. 10 (Outdoor unit is lower)  
Drain hose  
Connectable (VP16)  
Power cable  
Recommended breaker size  
16  
Size x Core number  
Connecting method  
1.5mm2 x 4 cores (Including earth cable)  
Terminal block (Screw fixing type)  
Mounting kit  
Connection wiring  
Accessories (included)  
Optional parts  
Wired remote control, Interface kit (SC-BIKN-E)  
The pipe length is 7.5m.  
Note (1) The data are measured at the following conditions.  
Item  
Indoor air temperature  
Outdoor air temperature  
Standards  
DB  
WB  
19˚C  
DB  
35˚C  
7˚C  
WB  
24˚C  
6˚C  
Operation  
Cooling  
Heating  
27˚C  
20˚C  
ISO-T1, JIS C 9612  
(2) This air-conditioner is manufactured and tested in conformity with the ISO.  
(3) The operation data are applied to the 220/230/240V districts respectively.  
(4) The refrigerant quantity to be charged includes the refrigerant in 15m connecting piping.  
(Purging is not required even for the short piping.)  
RWA000Z231  
A
ꢀꢁ  
'10 • SR-T-091D  
(4) Ceiling cassette-4way compact type (FDTC)  
Adapted to RoHS directive  
FDTC25VD  
Model  
Indoor unit FDTC25VD  
Outdoor unit SRC25ZJX-S  
Item  
Panel TC-PSA-25W-E  
Power source  
Operation data  
Nominal capacity  
Power consumption  
Running current  
Power factor  
220/230/240V  
Heating  
3.45 [ 0.9 (Min.)  
0.84  
~
50Hz  
Cooling  
kW  
kW  
A
2.55 [ 0.9 (Min.)~3.2 (Max.)]  
~4.7 (Max.)]  
0.6  
3.0/2.9/2.8  
91  
4.1/4.0/3.8  
92  
%
A
Inrush current  
4.1  
Cooling P-Hi : 38 Hi : 36 Me : 32 Lo : 29  
Heating P-Hi : 39 Hi : 38 Me : 33 Lo : 29.5  
Sound Pressure Level  
dB(A)  
mm  
47  
Exterior dimensions  
Height x Width x Depth  
Unit 248 × 570 × 570  
Panel 35 × 700 × 700  
595 x 780 x 290  
Exterior appearance  
(Munsell color)  
Plaster White  
( 6.8Y8.9/0.2 ) near equivalent  
Stucco White  
( 4.2Y7.5/1.1 ) near equivalent  
Net weight  
kg  
UNIT 15 PANEL 3.5  
38  
Refrigerant equipment  
Compressor type & Q'ty  
RM-B5077MDE1 (Rotary type) x 1  
Starting method  
Refrigerant oil  
Direct line start  
0.35 (DIAMOND FREEZE MA68)  
M shape fin & inner grooved tubing  
Electronic expansion valve  
Heat exchanger  
Refrigerant control  
Louver fin & inner grooved tubing  
Air handling equipment  
Fan type & Q'ty  
Turbo fan × 1  
Propeller fan × 1  
Motor <Starting method>  
W
CMM  
Pa  
33 <Direct line start>  
24 <Direct line start>  
Cooling P-Hi : 10 Hi : 9 Me : 8 Lo : 6.5  
Heating P-Hi : 10.5 Hi : 9.5 Me : 8.5 Lo : 7  
Cooling 29.5  
Heating 27.0  
Air flow (Standard)  
Available static pressure  
Outdoor air intake  
0
Not possible  
Air filter, Q'ty  
Pocket plastic net × 1 (Washable)  
Rubber sleeve (for fan motor)  
Polyurethane form  
Shock & vibration absorber  
Insulation (noise & heat)  
Electric heater  
Rubber sleeve (for Compressor)  
W
Remote controller  
wired : RC-E4 (option) wireless : RCN-TC-24W-ER (option)  
Room temperature control  
Thermostat by electronics  
Overload protection for fan motor  
Frost protection thermostat  
Internal thermostat for fan motor  
Abnormal discharge temperature protection.  
Safety equipment  
Liquid line : I/U 6.35 (1/4") Pipe 6.35 (1/4") × 0.8 O/U 6.35 (1/4")  
φ
φ
φ
Installation data  
Refrigerant piping size  
mm  
Gas line  
:
9.52 (3/8")  
9.52 (3/8") × 0.8  
φ
9.52 (3/8")  
φ
φ
Connecting method  
Flare piping  
Flare piping  
Refrigerant line (one way) length  
Max. 15m  
Vertical height difference between  
outdoor unit and indoor unit  
Max. 10m (Outdoor unit is higher)  
Max. 10m (Outdoor unit is lower)  
Refrigerant Quantity  
Drain pump  
R410A 1.2kg in outdoor unit (incl. the amount for the piping of : 15m)  
Built-in Drain pump  
Drain  
Hose Connectable with VP20  
Insulation for piping  
Standard Accessories  
Necessary (Both liquid & Gas lines)  
Mounting kit, Drain hose  
Drain elbow, Drain hole grommet  
Notes (1) The data are measured at the following conditions when the air flow is high mode.  
Item  
Indoor air temperature  
Outdoor air temperature  
Operation  
Cooling  
Heating  
DB  
WB  
DB  
35˚C  
7˚C  
WB  
24˚C  
6˚C  
27˚C  
19˚C  
20˚C  
(2) This packaged air-conditioner is manufactured and tested in conformity with the ISO.  
(3) Sound pressure level indicates the value in an anechoic chamber. During operation these value are somewhat higher due to  
ambient temperature.  
(4) The operation data indicates when the air-conditioner is operated at 220/230/240V 50Hz.  
(5) When wireless remote controller is used, fan is 3 speed setting (Hi-Me-Lo) only.  
RWA000Z234  
A
ꢀꢂ  
'10 • SR-T-091D  
Adapted to RoHS directive  
FDTC35VD  
Model  
Indoor unit FDTC35VD  
Outdoor unit SRC35ZJX-S  
Item  
Panel TC-PSA-25W-E  
Power source  
Operation data  
Nominal capacity  
Power consumption  
Running current  
Power factor  
220/230/240V  
Heating  
4.25 [ 0.9 (Min.)  
1.16  
~
50Hz  
Cooling  
kW  
kW  
A
3.6 [ 0.9 (Min.)~4.1 (Max.)]  
~5.1 (Max.)]  
1.07  
4.9/4.7/4.5  
99  
5.3/5.1/4.9  
99  
%
A
Inrush current  
5.3  
Cooling P-Hi : 41 Hi : 40 Me : 36 Lo : 30  
Heating P-Hi : 43 Hi : 42 Me : 35 Lo : 32  
Sound Pressure Level  
dB(A)  
mm  
50  
Exterior dimensions  
Height x Width x Depth  
Unit 248 × 570 × 570  
Panel 35 × 700 × 700  
595 x 780 x 290  
Exterior appearance  
( Munsell color )  
Plaster White  
( 6.8Y8.9/0.2 ) near equivalent  
Stucco White  
( 4.2Y7.5/1.1 ) near equivalent  
Net weight  
kg  
UNIT 15 PANEL 3.5  
38  
Refrigerant equipment  
Compressor type & Q'ty  
RM-B5077MDE1 (Rotary type) x 1  
Starting method  
Refrigerant oil  
Direct line start  
0.35 (DIAMOND FREEZE MA68)  
M shape fin & inner grooved tubing  
Electronic expansion valve  
Heat exchanger  
Refrigerant control  
Louver fin & inner grooved tubing  
Air handling equipment  
Fan type & Q'ty  
Turbo fan × 1  
Propeller fan × 1  
Motor <Starting method>  
W
CMM  
Pa  
33 <Direct line start>  
24 <Direct line start>  
Cooling P-Hi : 11 Hi : 9.5 Me : 9 Lo : 7  
Heating P-Hi : 11.5 Hi : 10.0 Me : 9 Lo : 8  
Cooling 32.5  
Heating 29.5  
Air flow (Standard)  
Available static pressure  
Outdoor air intake  
0
Not possible  
Air filter, Q'ty  
Pocket plastic net × 1 (Washable)  
Rubber sleeve (for fan motor)  
Polyurethane form  
Shock & vibration absorber  
Insulation (noise & heat)  
Electric heater  
Rubber sleeve (for Compressor)  
W
Remote controller  
wired : RC-E4 (option) wireless : RCN-TC-24W-ER (option)  
Room temperature control  
Thermostat by electronics  
Overload protection for fan motor  
Frost protection thermostat  
Internal thermostat for fan motor  
Abnormal discharge temperature protection.  
Safety equipment  
Liquid line : I/U 6.35 (1/4") Pipe 6.35 (1/4") × 0.8 O/U 6.35 (1/4")  
φ
φ
φ
Installation data  
Refrigerant piping size  
mm  
Gas line  
:
9.52 (3/8")  
9.52 (3/8") × 0.8  
φ
9.52 (3/8")  
φ
φ
Connecting method  
Flare piping  
Flare piping  
Refrigerant line (one way) length  
Max. 15m  
Vertical height difference between  
outdoor unit and indoor unit  
Max. 10m (Outdoor unit is higher)  
Max. 10m (Outdoor unit is lower)  
Refrigerant Quantity  
Drain pump  
R410A 1.2kg in outdoor unit (incl. the amount for the piping of : 15m)  
Built-in Drain pump  
Drain  
Hose Connectable with VP20  
Insulation for piping  
Standard Accessories  
Necessary (Both liquid & Gas lines)  
Mounting kit, Drain hose  
Drain elbow, Drain hole grommet  
Notes (1) The data are measured at the following conditions when the air flow is high mode.  
Item  
Indoor air temperature  
Outdoor air temperature  
Operation  
Cooling  
Heating  
DB  
WB  
DB  
35˚C  
7˚C  
WB  
24˚C  
6˚C  
27˚C  
19˚C  
20˚C  
(2) This packaged air-conditioner is manufactured and tested in conformity with the ISO.  
(3) Sound pressure level indicates the value in an anechoic chamber. During operation these value are somewhat higher due to  
ambient temperature.  
(4) The operation data indicates when the air-conditioner is operated at 220/230/240V 50Hz.  
(5) When wireless remote controller is used, fan is 3 speed setting (Hi-Me-Lo) only.  
RWA000Z234  
A
ꢀꢃ  
790  
Symbol  
A
Content  
14.5  
60  
60  
31  
2035 Ǿ9.5238"㧕㧔Flare㧕  
50 Ǿ12.712"㧕㧔Flare㧕  
Gas piping  
Model  
Liquid piping  
B
C
D
E
Ǿ6.3514"㧕㧔Flare㧕  
㧔Ǿ65㧕  
㧔Ǿ65㧕  
Hole on wall for right rear piping  
Hole on wall for left rear piping  
Drain hose  
VP16  
Outlet for wiring  
F
Outlet for pipingon both side㧕  
G
229  
3
798  
G
Wireless remote controller  
Outlet for down piping  
Refer to the above view㧕  
45  
60  
17.3  
Service space㧕  
Installation plate  
Unit  
Wired - remote controller  
50  
F
Option㧕  
Service space㧕  
106.5  
139  
585  
450  
106.5  
209  
100  
غ
120  
19  
Notes1The model name label is attached  
ޓ
ޓ
 
ޓ
 on the underside of the panel.  
ޓ
 2It takes the interface kit SC-BIKN-E㧕  
ޓ
ޓ
 
ޓ
 to connect the wired remote controller.  
Unit:mm  
55  
55  
C
D
E
B
A
403.6  
471.6  
531.8  
Space for installation and service when viewing from the front  
881.9  
Symbol  
A
Content  
26  
59.9  
59.9  
20.9  
Model 20,25,35  
Model 50,60  
Ǿ6.3514"Flare㧕  
㧔Ǿ65㧕  
㧔Ǿ65㧕  
VP16  
Ǿ9.5238"Flare㧕  
Ǿ12.712"Flare㧕  
Gas piping  
Liquid piping  
B
C
D
E
Hole on wall for right rear piping  
Hole on wall for left rear piping  
Drain hose  
Outlet for wiring  
F
Outlet for pipingon both side㧕  
G
220  
3
890  
G
Wireless remote controller  
Outlet for down piping  
Refer to the above view㧕  
Terminal block  
46.5  
60  
17.3  
61.5  
F
Installation plate  
Wired - remote controller  
Service space㧕  
Service space㧕  
Option㧕  
50  
120  
220  
650  
120  
220  
100  
450  
Unit  
غ
120  
19  
35  
35  
Notes1The model name label is attached  
ޓ
ޓ
 
ޓ
 on the underside of the panel.  
ޓ
 2It takes the interface kit SC-BIKN-E㧕  
ޓ
ޓ
 
ޓ
 to connect the wired remote controller.  
Unit:mm  
54  
B
A
D
C
58  
491.1  
520.8  
559.1  
Space for installation and service when viewing from the front  
E
Symbol  
A
Content  
83.5  
620  
726  
156.5  
103.5  
211.5  
25,35 : Ǿ9.5238"㧕㧔Flare㧕  
50 : Ǿ12.712"㧕㧔Flare㧕  
Ǿ6.3514"㧕㧔Flare㧕  
Installation plate  
Unit  
Gas piping  
Model  
30.5  
138.5  
255  
255  
Liquid piping  
B
C
D
E
Hole on wall for right rear piping  
Hole on wall for left rear piping  
Drain hose  
㧔Ǿ65㧕  
㧔Ǿ65㧕  
VP16  
F
Screw point fasten the indoor unit  
Outlet for pipingon both side㧕  
F
G
Ǿ5  
F
A
B
35  
10  
840  
10  
76.3  
157.2  
85.3  
22.7  
F
F
D
E
C
Service space㧕  
50 65  
65  
30.5  
804  
25.5  
50+Service space  
482.8  
Space for installation and service when viewing from the front  
860  
238  
Wireless remote controller  
Wired remote controller  
Option㧕  
60  
غ
120  
19  
17.3  
Notes  
1Themodelnamelabelisattachedontherightsideoftheunit.  
ޓ
2IttakestheinterfacekitSC-BIKN-Etoconnectthewiredremotecontroller.  
3Incaseofwallinstallation,leavetheunit150mmorlessfromthefloor.  
G
6
Unit:mm  
12  
Outlet for down piping  
Refer to the above view㧕  
60  
15  
11  
190  
160  
30.3  
174.4  
40  
52  
41  
148  
170  
30  
19  
(Suspension bolts pitch)  
515  
13  
30  
30  
30  
230  
11.2  
253  
455  
150  
150  
120  
20  
150  
80  
21  
177  
32  
20  
80 40  
11.3  
203.7  
Decorative panel  
530Suspension bolts pitch)  
G
Symbol  
A
Content  
φ
Gas piping  
9.52(  
3
8"Flare  
4"Flare  
Liquid piping  
Drain piping  
Hole for wiring  
φ
6.35  
1
B
C
D
F
VP20  
I.D.20,O.D.26  
Note  
2)  
φ
25  
Suspension bolts  
M10 or M8  
Ducting for air outlet  
G
Knock out  
G
G
Space for installation and service  
Control  
box  
Air return  
grille  
1000 or more  
Air supply  
185  
190  
D
Obstacle  
223  
413  
700  
21  
200  
Make a space of 4000 or more between  
the units when installing more than one.  
48  
Drain hose piece  
Accessory  
140  
60  
φ
6-  
4
Installed on site  
Holes for  
570  
325  
Remote controller  
tapping screws  
Option)  
295 325  
F
C
B
A
145  
Hole  
100  
120  
19  
G
Hanger plate for  
suspension bolt  
Unit:mm  
Notes1The model name label is attached on the control box lid.  
VP20 on site.  
2Prepare the connecting socke  
t
3This unit is designed for 2x2 grid ceiling.  
If it is installed on a ceiling other than 2x2 grid ceiling,  
provide an inspection port on the control box side.  
Notes  
1It must not be surrounded by walls on the four sides.  
2The unit must be fixed with anchor bolts. An anchor bolt must not  
protrude more the 15mm.  
3Where the unit is subject to strong winds, lay it in such  
a direction that the blower outlet faces perpendicularly  
to the dominant wind direction.  
4Leave 1m or more space above the unit.  
5A wall in front of the blower outlet must not exceed the units height.  
6The model name label is attached on the right side of the unit.  
Symbol  
Content  
Service valve connectiongas side)  
A
B
C
D
E
φ12.712")(Flare)  
Service valve connectionliquid side)  
Pipecable draw-out hole  
Drain discharge hole  
φ6.3514")(Flare)  
φ20 × 5places  
Anchor bolt hole  
M10 × 4places  
520.6  
161  
327.3  
50.6  
12  
38.6  
D
E
L3  
Intake  
L4  
L2  
Service  
space  
(
)
Intake  
Outlet  
L1  
327.3  
89  
510  
201  
17.9  
71.2  
Minimum installation space  
800  
Examples of  
installation  
I  
I  
IV  
Dimensions  
L1  
L2  
L3  
L4  
Open  
100  
280  
Open  
80  
280  
75  
180  
Open  
Terminal block  
100  
80  
Open  
80  
Open  
250  
250  
148.4  
33.5  
C
B
Unit:mm  
A
Notes  
1It must not be surrounded by walls on the four sides.  
2The unit must be fixed with anchor bolts. An anchor bolt must not  
protrude more the 15mm.  
3Where the unit is subject to strong winds, lay it in such  
a direction that the blower outlet faces perpendicularly  
to the dominant wind direction.  
Symbol  
Content  
Service valve connectiongas side)  
A
B
C
φ9.5238")(Flare)  
Service valve connectionliquid side)  
Pipecable draw-out hole  
Drain discharge hole  
φ6.3514")(Flare)  
φ20 × 2places  
D
E
Anchor bolt hole  
M10 × 4places  
4Leave 1m or more space above the unit.  
5A wall in front of the blower outlet must not exceed the units height.  
6The model name label is attached on the lower right corner of the front panel.  
390.6  
50.6  
12  
E
D
L3  
Intake  
L4  
L2  
Service  
space  
(
)
Intake  
Outlet  
L1  
390.6  
111.6  
510  
780  
158.4  
17.9  
61.9  
Minimum installation space  
Examples of  
installation  
I  
I  
IV  
Dimensions  
L1  
L2  
L3  
L4  
Open  
100  
280  
Open  
80  
280  
75  
180  
Open  
Terminal block  
100  
80  
Open  
80  
Open  
250  
250  
138.4  
33.5  
C
B
Unit:mm  
A
Notes  
1It must not be surrounded by walls on the four sides.  
2The unit must be fixed with anchor bolts. An anchor bolt must not  
protrude more the 15mm.  
3Where the unit is subject to strong winds, lay it in such  
a direction that the blower outlet faces perpendicularly  
to the dominant wind direction.  
4Leave 1m or more space above the unit.  
5A wall in front of the blower outlet must not exceed the units height.  
6The model name label is attached on the lower right corner of the front panel.  
Symbol  
Content  
Service valve connectiongas side)  
A
B
C
D
E
φ12.712")(Flare)  
Service valve connectionliquid side)  
Pipecable draw-out hole  
Drain discharge hole  
φ6.3514")(Flare)  
φ20 × 5places  
Anchor bolt hole  
M10 × 4places  
520.6  
161  
327.3  
50.6  
12  
38.6  
D
E
L3  
Intake  
L4  
L2  
Service  
space  
(
)
Intake  
Outlet  
L1  
327.3  
89  
510  
201  
17.9  
Minimum installation space  
800  
71.2  
Examples of  
installation  
I  
I  
IV  
Dimensions  
L1  
L2  
L3  
L4  
Open  
100  
280  
Open  
80  
280  
75  
180  
Open  
Terminal block  
100  
80  
Open  
80  
Open  
250  
250  
148.4  
33.5  
C
B
Unit:mm  
A
'10 • SR-T-091D  
(3) Remote controller  
(a) Wireless remote controller  
Models SRK, SRF, SRR  
٨
The wireiess remote controller in the following figure shows for the SRK-50ZJ-S type.  
Unit: mm  
60  
17.3  
Model FDTC (Option parts)  
60  
17  
23  
'10 • SR-T-091D  
(b) Wired remote controller (option parts)  
Wiring outlet  
Cut off the upper thin part of remote control lower case with a nipper or knife,  
and grind burrs with a file etc.  
Exposed mounting  
In case of pulling out  
from upper left  
In case of pulling out  
from center  
0.3mm2×2 cores.  
48  
Upper part  
In case of pulling out  
from center  
In case of pulling out  
from upper left  
Lower case  
L C D  
Lower part  
Sheath  
TEMP  
ON/OFF  
Sheath  
Upper  
Board  
Upper  
Upper cace  
Upper cace  
Board  
X
Y
X
Y
Lower  
Lower  
Wiring  
Wiring  
X, Y Terminal block  
Attach M3 screw  
with washer  
In case of pulling out from center  
In case of pulling out from  
upper left  
The peeling-off length of sheath  
غ
120  
Pulling out from upper left Pulling out from center  
X wiring : 215mm  
Y wiring : 195mm  
X wiring : 170mm  
Y wiring : 190mm  
The peeling-off length  
of sheath  
Embedded mounting  
Remote control installation dimensions  
120  
Wall surface  
Tighten the screws after  
cutting off the thin part of  
screw mounting part.  
Remote  
control  
outline  
46  
23  
Wiring  
44  
11.5  
11  
Wiring oulet  
Electrical box  
12×7 Slot hole  
Installation hole  
9.5×5 Slot hole 4places䋩  
Not included䋩  
1Installation screw for remote control  
M4 Screw (2 pieces)  
19  
Unit:mm  
Wiring specifications  
(1) If the prolongation is over 100m, change to the size below.  
2
But, wiring in the remote controller case should be under 0.5mm . Change the wire size outside of  
the case according to wire connecting. Waterproof treatment is necessary at the wire connecting  
section. Be careful about contact failure.  
Length  
Wiring thickness  
2
100 to 200m  
Under 300m  
Under 400m  
Under 600m  
0.5mm ×2 cores  
2
0.75mm ×2 cores  
2
1.25mm ×2 cores  
2
2.0mm ×2 cores  
PJZ000Z274  
24  
LM2  
LM1  
SMI  
FMI  
Description  
Item  
CNE-CNY Connector  
M
M
M
M
Fan motor  
FMI  
SMI  
LM1,2  
HD  
ThI  
Th2,3  
DS  
F
Flap motor  
Louver motor  
5
5
5
Humidity sensor  
Room temp. sensor  
Heat exch. sensor  
Diode stack  
1
3
4
5
6
CNY  
CNX  
CNM  
CNU  
G
Fuse  
PRINTED  
CIRCUIT  
BOARD  
T
Va  
Terminal block  
Varistor  
HEAT  
EXCHANGER  
F
L
Mark  
Color  
250V 3.15A  
Va  
BK  
BL  
RD  
WH  
Y
Black  
U
Blue  
Red  
S/N  
White  
Yellow  
DS  
J
YG YellowGreen  
HEAT  
EXCHANGER  
CNS  
5
CNF  
CNE  
CNG  
2
2
2
2
8
to  
to  
to  
DISPLAY  
WIRELESS  
R-AMP  
1
2/N  
3
Power Source  
1 Phase  
220230240V 50Hz  
T
BACK-UP SW  
HD  
̪
Th3  
Th2  
ThI  
̪35,50  
ONLY  
TO OUTDOOR  
UNIT  
Description  
Item  
CNE-CNY Connector  
Fan motor  
FMI  
SM1,2  
LM1,2  
IM  
Th1  
Th2 1,2  
Th3  
LS  
5
5
5
5
DISPLAY  
WIRELESS RECEIVER  
BACK-UP SW  
M
M
M
LM1  
LM2  
12  
Flap motor  
Louver motor  
Inlet motor  
CNE  
CNG  
CNX1  
CNX2  
PRINTED  
CIRCUIT  
BOARD  
t
Th1  
Room temp. sensor  
Heat exch. sensor  
Humidity sensor 50,60 only㧕  
Limit switch  
5
5
5
5
SM1  
SM2  
t
Th2  
Th2  
1
2
DS  
M
DS  
Diode stack  
t
F
Fuse  
T
Terminal block  
Varistor  
5
5
M
IM  
Va  
2
5
CNF  
CNS  
Th3  
CNY  
LS  
INTERFACE KIT  
SC-BIKN-E  
Color Marks  
Mark  
Color  
G
YG  
BK  
Black  
U
Va  
BL  
RD  
WH  
Y
Blue  
RD  
WH SN  
1
BK  
WH  
Y
Red  
3
4
5
6
F
J
RD  
HEAT  
EXCHANGER  
CNU  
250V  
3.15A  
M
White  
Yellow  
BL  
L
BK  
FMI  
YG YellowGreen  
Power source  
1 phase 220 - 240 V 50Hz  
T
TO OUTDOOR UNIT  
1
2N  
3
2/N  
POWER WIRES  
SIGNAL WIRE  
1
3
HEAT  
EXCHANGER  
Description  
Item  
CNE-CNX2 Connector  
DISPLAY  
WIRELESS RECEIVER  
BACK-UP SW  
Fan motor  
FMI  
SM1,2  
DM1  
DM2  
Th1  
Th2 1,2  
Th3  
DS  
5
5
5
5
10  
M
M
M
DM1  
DM2  
CNE  
CNG  
Flap motor  
CNX1  
CNX2  
AIR SELECTION SW  
Damper motor  
Damper arm motor  
Room temp. sensor  
Heat exch. sensor  
Humidity sensor  
Diode stack  
PRINTED  
CIRCUIT  
BOARD  
t
Th1  
5
5
5
5
SM1  
SM2  
t
Th21  
DS  
M
F
Fuse  
t
Th22  
T
Terminal block  
Varistor  
Va  
2
5
CNF  
CNS  
Th3  
INTERFACE KIT  
SC-BIKN-E  
Color Marks  
Mark  
Color  
G
YG  
BK  
Black  
U
Va  
BL  
Blue  
RD  
WH SN  
1
BK  
WH  
YE  
RD  
WH  
YE  
Red  
3
4
5
6
F
J
RD  
HEAT  
EXCHANGER  
CNU  
250V  
3.15A  
M
White  
Yellow  
BL  
L
BK  
FMI  
YG YellowGreen  
Power source  
1 phase 220 - 240 V 50Hz  
T
TO OUTDOOR UNIT  
1
2N  
3
2/N  
POWER WIRES  
SIGNAL WIRE  
1
3
HEAT  
EXCHANGER  
FM  
M
CONTROL  
BOX  
1
3
4
5
6
CNU  
5
INTERFACE KIT  
SC-BIKN-E  
CNS  
F
250V  
0.16A  
DM  
SN  
WH  
RD  
RD  
M
U
CNW  
Va  
1  
L
BK  
RD  
F
250V 3.15A  
J
FS  
WH  
WH  
YG  
G
PRINTED CIRCUIT  
BOARD  
CNY  
CNE  
CNG  
2
2
BK  
8
T
2
2
1
2/N  
3
10  
Power source  
1 phase 220 - 240 V 50Hz  
DISPLAY  
TO OUTDOOR UNIT  
WIRELESS  
RECEIVER  
TO OUTDOOR UNIT  
Description  
Th1 Th2  
Description  
Th3  
2/N  
POWER WIRES  
SIGNAL WIRE  
1
3
Color Marks  
Mark  
Meaning of Marks  
Item  
Color  
Mark  
YE  
YG  
Color  
Item  
BK  
BL  
Black  
Blue  
Yellow  
YellowGreen  
CNE-CNY  
F
Connector  
Fuse  
Fan motor  
Drain motor  
Float Switch  
Th1  
Th2  
Th3  
T
Room temp. sensor  
Heat exch. sensor 1  
Heat exch. sensor 2  
Terminal block  
OR  
RD  
WH  
Orange  
Red  
White  
FM  
DM  
FS  
I
Va  
Varistor  
Color Marks  
LED3  
LM14  
SW2  
Indication lampRed-Inspection)  
TB1  
Terminal block Power source)  
(□ mark)  
Terminal block Signal line)□mark)  
Thermistor Remote controller)  
Thermistor Return air)  
Thermistor Heat exchanger)  
Relay for DM  
Mark Color  
BK Black  
BL Blue  
BR Brown  
OR Orange  
RD Red  
CNBZ  
DM  
F200203  
Connector  
Drain motor  
Fuse  
Fan motor  
Float switch  
Indication lamp  
Green-Normal operation)  
Louver motor  
TB2  
Thc  
ThI-A  
ThI-R1,2,3  
X4  
Remote controller communication  
address  
Plural units MasterSlave setting  
Model capacity setting  
FM  
FS  
I
SW5  
SW6  
SW7-1  
LED2  
Operation check,Drain motor test run  
WH White  
mark  
Closed-end connector  
Y
Yellow  
YGN YellowGreen  
Remote controller  
TB2  
Control PCB  
FS  
WH  
1
1
WH  
WH  
WH  
WH  
RD  
1
X
Y
X
Y
CNB  
1
CNI  
BL  
BK  
WH  
3
ThC  
t°  
2
2
RD  
2
LED2  
LED3  
CNI2  
WH  
YGN  
BL  
BL  
3
4
BL  
BL  
1
BK  
1
YGN  
YGN  
CNH  
BK  
ThI-A  
t°  
t°  
t°  
t°  
2
BK  
2
Power PCB  
RD  
RD  
RD  
RD  
RD  
CNH2  
WH  
BK  
1
1
YGN  
2
2
Connecting line between  
YGN  
RD  
7
5
3
CNW3  
CNW2  
RD  
RD  
RD  
5
6
RD  
RD  
1
SW2  
3
4
5
3
1
F2003.15A)  
indoor unit and outdoor unit  
RD  
4
1
2
3
ThI-R1  
ThI-R2  
ThI-R3  
2
BK  
Power circuit  
2
1
2
WH  
5
2
Power source line  
Signal line  
Earth  
3
F2013.15A)  
BL  
1
CNW1  
BL  
BL  
BL  
BL  
BL  
BL  
1
2
3
SW5  
SW6  
SW7  
Y
Y
7
8
Y
Y
3
4
BK  
BK  
1 CNW4  
[ ]  
3
4
CNW0  
WH  
CNN  
Y
X4  
3
YGN  
BL  
TB1  
4
5
F203  
0.16A)  
F202  
1.0A)  
4
5
1
3
1
4
5
6
7
BK  
BK  
9
BK  
BK  
5
6
BK  
5
6
RD BL BR OR WH  
WH BR  
CNR  
WH  
CNM  
WH  
10  
BK  
1
BK  
BK  
BK  
BK  
BK  
BK  
BK  
BK  
BK  
BK  
BK  
BK  
BK  
BK  
BK  
BK  
BK  
BK  
BK  
BK  
1
BK  
BK  
BK  
BK  
BK  
BK  
BK  
BK  
BK  
BK  
BK  
BK  
BK  
BK  
BK  
BK  
BK  
BK  
BK  
BK  
1
2
3
4
5
6
7
8
9
LM1  
M
CNN2  
BK  
2
Y
1
CNC  
WH  
2
2
5
6
4
3
2
CNR2  
BL  
CNM3  
3
4
5
3
4
Y
RD BL BR OR WH  
RD  
5
5
6
4
3
2
1
6
M
1~  
DM  
CNM4  
WH  
LM2  
M
2
3
4
5
7
RD BL BR OR WH  
Option  
8
+12  
1
9
2
3
4
5
6
XR1  
(Operation)  
(Heating)  
M
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
CNJ  
10  
FMI  
CNT  
BL  
XR2  
XR4  
1
WH  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
(Compressor ON)  
(Inspection)  
XR3  
LM3  
M
2
3
4
5
XR5Remote operation input:volt-free contact)  
1
Notes 1.  
indicates wiring on site.  
LM4  
M
2
3
4
5
   2. TB1 is the terminal block for heavy currentconnecting line between  
indoor unit and outdoor unit,  
and TB2 is the terminal block for weak currentremote controller.  
   3. See the wiring diagram of outside unit about the line between  
inside unit and outside unit.  
CNJ2  
WH  
   4. Use twin core cable0.3mm2X2at remote controller line. See spec  
   sheet of remote controller in case that the total length is more than 100m.  
   5. Do not put remote controller line alongside power source line.  
POWER SOURCE 1220240V 50Hz1220V 60Hz  
Item  
Description  
Compressor motor  
CNEEVCN20S Connector  
CM  
EEV  
FMo  
L
Electric expansion valvecoil)  
Fan motor  
L
Reactor  
T1,2  
TH1  
TH2  
TH3  
20S  
Terminal block  
Heat exchanger sensoroutdoor unit)  
Outdoor air temp.sensor  
Discharge pipe temp.sensor  
Solenoid valve for 4 way valve  
TERMINAL  
BLOCK  
PWB ASSY MAIN)  
PWB ASSY SUB)  
POWER  
TRANSISTOR  
T1  
L
FUSE  
R
IN  
BK)  
F8  
F2  
U
V
RD)  
WH)  
BK)  
P
R
O
O
R
U
250V 20A  
BK)  
WH)  
WH)  
BK)  
ACTIVE  
FILTER  
UNIT  
250V 20A  
250V 20A  
WHS IN  
+
+
+
NU  
V
M
N
S
S
3  
WH)  
NV  
NW  
W
BR)  
W
YG)  
CM  
R
OUT  
S-1  
S-2  
Mark  
BK  
Color  
Black  
Brown  
G1  
YG)  
TERMINAL  
BLOCK  
CNMAIN  
CNSUB  
C-2  
CN20S  
RD)  
BR  
T2  
1
F3 250V 1A  
OR  
RD  
Orange  
Red  
TO INDOOR UNIT  
2
M
N
WH  
Y
White  
CNFAN  
2
RD)  
POWER WIRES  
SIGNAL WIRE  
1
3
N
FMo  
3
SWITCHING POWER  
CIRCUIT  
Yellow  
[
]
YG)  
YG  
YellowGreen  
CNTH  
CNEEV  
20S  
M
t  
t゜  
t゜  
EEV  
5 or 6 wires  
TH1 TH2 TH3  
Power cable, indoor-outdoor connecting wires  
Model  
MAX running current  
Power cable size  
Power cable length  
indoor-outdoor  
wire size x number  
Earth wire size  
mm)  
mm2  
m)  
A)  
50  
2.0  
φ1.6mm x 3  
φ1.6mm  
14  
18  
The specifications shown in the above table are for units without heaters. For units with heaters, refer  
to the installation instructions or the construction instructions of the indoor unit.  
Switchgear of Circuit breaker capacity which is calculated from MAX. over current should be chosen  
along the regulations in each country.  
The cable specifications are based on the assumption that a metal or plastic conduit is used with no  
more than three cables contained in a conduit and a voltage drop is 2%. For an installation falling  
outside of these conditions, please follow the internal cabling regulations. Adapt it to the regulation  
in effect in each country.  
Item  
Description  
Compressor motor  
CM  
Connector  
CN20S  
CNTH  
L
TO INDOOR UNIT  
POWER WIRES  
CNEEV  
CNFAN  
2
1
3
N
EEV  
FMo  
L
Electric expansion valvecoil)  
Fan motor  
[
]
SIGNAL WIRE  
PWB ASSY  
Reactor  
POWER  
T1 T2  
POWER SOURCE  
220240V 50Hz/~220V 60Hz  
T
Terminal block  
TRANSISTOR  
250V 15A  
t  
F2  
BKR.IN  
TH1  
TH2  
TH3  
20S  
Heat exchanger sensoroutdoor unit)  
Outdoor air temp.sensor  
Discharge pipe temp.sensor  
Solenoid valve for 4 way valve  
RD)  
WH)  
BK)  
P
U
V
L
1
2
3
U
+ +  
250V 20A  
NOISE  
FILTER  
M
V
N
3  
W
WHS.IN  
W
N
CM  
F3 250V 1A  
YG)  
PAM  
RDC-2  
F4  
CIRCUIT  
Mark  
BK  
Color  
Black  
M
YGG1  
CNFAN  
250V 10A  
TERMINAL  
BLOCK  
FMo  
SWITCHING POWER  
CIRCUIT  
OR  
RD  
Orange  
Red  
T
CN20S  
CNEEV  
CNTH  
WH  
Y
White  
ttt゜  
Yellow  
M
20S  
YG  
YellowGreen  
EEV  
5 or 6 wires  
TH1 TH2 TH3  
Power cable, indoor-outdoor connecting wires  
Model  
MAX running current  
Power cable size  
Power cable length  
indoor-outdoor  
wire size x number  
Earth wire size  
mm)  
mm2  
m)  
A)  
20  
25  
35  
8
2.0  
32  
φ1.6mm x 3  
φ1.6mm  
The specifications shown in the above table are for units without heaters. For units with heaters, refer  
to the installation instructions or the construction instructions of the indoor unit.  
Switchgear of Circuit breaker capacity which is calculated from MAX. over current should be chosen  
along the regulations in each country.  
The cable specifications are based on the assumption that a metal or plastic conduit is used with no  
more than three cables contained in a conduit and a voltage drop is 2%. For an installation falling  
outside of these conditions, please follow the internal cabling regulations. Adapt it to the regulation  
in effect in each country.  
POWER SOURCE 1220240V 50Hz1220V 60Hz  
Item  
Description  
Compressor motor  
CM  
CNEEV20S  
Connector  
EEV  
FMo  
L
Electric expansion valvecoil)  
Fan motor  
L
Reactor  
T1,2  
TH1  
TH2  
TH3  
20S  
Terminal block  
Heat exchanger sensoroutdoor unit)  
Outdoor air temp.sensor  
Discharge pipe temp.sensor  
Solenoid valve for 4 way valve  
TERMINAL  
BLOCK  
PWB ASSY MAIN)  
PWB ASSY SUB)  
POWER  
TRANSISTOR  
T1  
FUSE  
R
IN  
BK)  
F8  
F2  
L
U
V
RD)  
WH)  
BK)  
P
R
O
O
R
U
250V 20A  
BK)  
WH)  
WH)  
BK)  
ACTIVE  
FILTER  
UNIT  
250V 20A  
250V 20A  
WHS IN  
+
+
+
NU  
V
M
N
S
S
3  
WH)  
NV  
NW  
W
BR)  
W
YG)  
CM  
R
OUT  
S-1  
S-2  
Mark  
BK  
Color  
Black  
G1  
YG)  
TERMINAL  
BLOCK  
CNMAIN  
CNSUB  
C-2  
CN20S  
RD)  
BR  
Brown  
T2  
F3 250V 1A  
OR  
RD  
Orange  
Red  
1
TO INDOOR UNIT  
2
M
N
WH  
Y
White  
CNFAN  
2
RD)  
POWER WIRES  
SIGNAL WIRE  
1
3
N
FMo  
3
SWITCHING POWER  
CIRCUIT  
Yellow  
[
]
YG)  
YG  
YellowGreen  
CNTH  
CNEEV  
20S  
M
t  
t゜  
t゜  
EEV  
5 or 6 wires  
TH1 TH2 TH3  
Power cable, indoor-outdoor connecting wires  
Model  
MAX running current  
Power cable size  
Power cable length  
indoor-outdoor  
wire size x number  
Earth wire size  
mm)  
mm2  
m)  
A)  
40  
50  
60  
12  
21  
2.0  
φ1.6mm x 3  
φ1.6mm  
14  
18  
The specifications shown in the above table are for units without heaters. For units with heaters, refer  
to the installation instructions or the construction instructions of the indoor unit.  
Switchgear of Circuit breaker capacity which is calculated from MAX. over current should be chosen  
along the regulations in each country.  
The cable specifications are based on the assumption that a metal or plastic conduit is used with no  
more than three cables contained in a conduit and a voltage drop is 2%. For an installation falling  
outside of these conditions, please follow the internal cabling regulations. Adapt it to the regulation  
in effect in each country.  
INVERTER RESIDENTIAL AIR CONDITIONERS  
Air-Conditioning & Refrigeration Systems Headquarters  
16-5, 2-chome, Kounan, Minato-ku, Tokyo, 108-8215, Japan  
Fax : (03) 6716-5926  
Because of our policy of continuous improvement, we reserve the right to make changes in all specifications without notice.  
C
Copyright MITSUBISHI HEAVY INDUSTRIES, LTD.  

Linak Twindrive Hb12 User Manual
Master Lock B70 User Manual
Mitsubishi Motors Automobile Parts 4d6 User Manual
Oricom 200 User Manual
Samsung Sf 330 User Manual
Sanyo Cadnica Kr 2300sce User Manual
Soleus Air Kfthp 24 Od User Manual
Tekkeon Healthy White Hx6732 User Manual
Trion Air Boss 22 Series User Manual
Xerox Workcentre 7328 User Manual