Zephyr Ventilation Hood AK8800AG User Manual

Willow  
AK8800AS  
AK8800AG  
INTENDED FOR OUTDOOR COVERED PATIO OR LANAI AREA.  
Model number:  
Serial Number:  
Date of Purchase:  
Sales Dealer:  
AUG08.0101 © 2008 Zephyr Corporation  
READ AND SAVE THESE INSTRUCTIONS  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY NOTICE................................................................. 2-3  
LIST OF MATERIALS.......................................................  
4
INSTALLATION  
Ducting Calculation Sheet.......................................  
Mounting Height & Clearance................................  
Ducting Options...........................................................  
Specications ...............................................................  
Electrical.........................................................................  
5
6
7
8
9
Installing the Power Pack........................................ 10  
CONTROLS  
Rocker Switch Controls............................................ 11  
MAINTENANCE  
Cleaning and Installing Filters ............................... 12  
Lights................................................................................ 13  
TROUBLESHOOTING................................................................ 14  
LIST OF PARTS AND ACCESSORIES.............................. 15  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
READ AND SAVE THESE INSTRUCTIONS  
WARNING  
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE.  
WARNING  
TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:  
a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer.  
b. Before servicing or cleaning unit, switch power off at service panel and lock panel to prevent power from being switched on accidentally.  
When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service  
panel.  
c. This unit must be grounded and protected by a GFCI.  
d. Suitable for use in damp locations only when installed in a GFCI PROTECTED branch-circuit.  
CAUTION  
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. Take care when using cleaning  
agents or detergents. Suitable for use in household cooking area.  
WARNING  
TO REDUCE THE RISK OF RANGE TOP GREASE FIRE:  
a. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly  
on low or medium settings.  
b. Always turn hood ON when cooking at high heat or when aming food  
c. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or lter.  
d. Use proper pan size. Always use cookware appropriate for the size of the surface element.  
e. Keep fan, lters and grease laden surfaces clean.  
f. Use high setting on hood only when necessary.  
g. Don’t leave hood unattended when cooking.  
h. Always use cookware and utensils appropriate for the type of and amount of food being prepared.  
WARNING  
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE, OBSERVE THE FOLLOWING:  
a. SMOTHER FLAMES with a close-tting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS.  
If the ames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.  
b. NEVER PICK UP A FLAMING PAN – You may be burned.  
c. DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.  
d. Use an extinguisher ONLY if:  
1. You know you have a Class ABC extinguisher, and you already know how to operate it.  
2. The re is small and contained in the area where it started.  
3. The re department is being called.  
4. You can ght the re with your back to an exit  
WARNING  
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:  
a. Installation work and electrical wiring must be done by qualied person(s) in accordance with all applicable codes and standards.  
Including re-rated construction.  
b. Sufcient air is needed for power combustion and exhausting of gases through the ue (chimney) of fuel burning equipment to prevent  
back-drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National  
Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and  
the local code authorities.  
c. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.  
d. Ducted fans must always vent to the outdoors.  
e. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFI  
(Ground Fault Interrupter protected branch circuit).  
g. NEVER place a switch where it can be reached from a tub or shower.  
h. Make sure the power is off before installing, wiring or maintenancing.  
WARNING  
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAUTION  
To reduce risk of re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings,  
attics, crawl spaces or garages.  
OPERATION  
Always leave safety grilles and lters in place. Without these components, operating blowers could catch onto hair, ngers  
and loose clothing.  
The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation,  
maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to  
negligence and the warranty of the unit automatically expires due to improper maintenance.  
ELECTRICAL REQUIREMENTS  
Important:  
Observe all governing codes and ordinances.  
It is the customer’s responsibility:  
-
-
To contact a qualied electrical installer.  
To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70  
latest edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and  
all local codes and ordinances.  
If codes permit and a separate ground wire is used, it is recommended that a qualied electrician determine that the  
ground path is adequate.  
Do not ground to a gas pipe.  
Check with a qualied electrician if you are not sure the range hood is properly grounded.  
Do not have a fuse in the neutral or ground circuit.  
*National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269  
** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575  
This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit  
protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to  
Electrical Diagram on product.  
AK8800Ax - 710W, 5.95 Amps  
A cable locking connector (not supplied) might also be required by local codes. Check with local requirements, purchase  
and install appropriate connector if necessary.  
FEDERAL COMMUNICATION COMMISSION INTERFACE STATEMENT  
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant  
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful  
interference in a residential installation.  
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in  
accordance with the instructions, may cause harmful interference to radio communications. However, there  
is no guarantee that interference will not occur in a particular installation. If this equipment does cause  
harmful interference to radio or television reception, which can be determined by turning the equipment off  
and on, the user is encouraged to try to correct the interference by one of the following measures:  
. Reorient or relocate the receiving antenna.  
. Increase the separation between the equipment and receiver.  
. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  
. Consult the dealer or an experienced radio/TV technician for help  
SUITABLE FOR USE IN DAMP LOCATIONS WHEN INSTALLED IN A GFCI PROTECTED BRANCH-  
CIRCUIT. INTENDED FOR OUTDOOR COVERED PATIO OR LANAI AREA.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODELS: AK8800AS AND AK8800AG  
PARTS SUPPLIED  
1 - 316S High quality stainless steel Power Pack (AK8800AS)  
or  
1 - Gray powder coated Power Pack (AK8800AG)  
2 - Bafe lters  
2 - Halogen light bulbs (pre-installed)  
1 - Dual internal blower (pre-installed)  
1 - 8” round adapter  
1 - Hardware package  
Suction Cup (1)  
M4 x 1” (6)  
M4 x 8 (4)  
Wire Caps (3)  
HARDWARE PACKAGE CONTENTS  
PARTS NOT SUPPLIED  
- Ducting, conduit and all installation tools  
- Cable connector (if required by local codes)  
- Optional stainless steel hood liner (AK08xxAS)  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Equivalent number  
length x used  
Equivalent number  
length x used  
Duct pieces  
Duct pieces  
=
To t a l  
=
To t a l  
Ft.  
Ft.  
Ft.  
Ft.  
3-1/ 4” x 10” 1 Ft.  
x (  
x (  
x (  
x (  
)
)
)
)
=
=
=
=
Ft.  
6” Round  
wall cap  
30 Ft.  
x (  
)
=
Rect.,  
straight  
with damper  
6” Round,  
straight  
1 Ft.  
Ft.  
Ft.  
6” Round,  
roof cap  
30 Ft.  
1 Ft.  
x (  
x (  
)
)
=
=
7”-10” Round, 1 Ft.  
straight  
6” roundto  
3-1/ 4” x 10”  
rect.  
transition  
3-1/ 4” x 10” 15 Ft.  
Ft.  
6” roundto  
3-1/ 4” x 10”  
rect.  
16 Ft.  
x (  
)
=
0
Rect.90  
elbow  
transition  
0
Ft.  
3-1/ 4” x 10” 9 Ft.  
x (  
)
=
90 elbow  
0
Rect.45  
elbow  
Ft.  
Ft.  
7” - 10”  
Round,  
15 Ft.  
9 Ft.  
x (  
x (  
)
)
=
=
0
90 elbow  
Ft.  
Ft.  
3-1/ 4” x 10” 24 Ft.  
x (  
x (  
)
)
=
=
0
Rect.90  
7” - 10”  
Round,  
flat elbow  
0
45 elbow  
3-1/ 4” x 10” 30 Ft.  
Rect.  
wall cap  
with damper  
Ft.  
Ft.  
Ft.  
7” - 10”  
30 Ft.  
30 Ft.  
8 Ft.  
x (  
x (  
x (  
)
)
)
=
=
=
Round  
wall cap  
with damper  
Ft.  
Ft.  
3-1/ 4” x 10” 5 Ft.  
Rect.to  
6” round  
transition  
x (  
x (  
)
)
=
=
7” - 10”  
Round,  
roof cap  
7” roundto  
3 1/ 4” x 10”  
rect.  
3-1/ 4” x 10” 20 Ft.  
Rect.to  
6” round  
transition  
transition  
0
90 elbow  
Ft.  
7” roundto  
3-1/ 4” x 10”  
rect.  
23 Ft.  
x (  
)
=
Ft.  
6” Round,  
15 Ft.  
9 Ft.  
x (  
x (  
)
)
=
=
0
90 elbow  
transition  
0
90 elbow  
Ft.  
Ft.  
6” Round,  
Subtotal column2 =  
Subtotal column1 =  
Ft.  
Ft.  
Ft.  
0
45 elbow  
Subtotal column1 =  
Total ductwork  
=
Maximum Duct Length: For satisfactory air movement, the  
total duct length should not exceed 100 equivalent feet.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Minimum mount height between range top to hood  
bottom should be no less than 30”.  
Maximum mount height should be no higher than  
36”.  
It is important to install the hood at the proper  
mounting height. Hoods mounted too low could  
result in heat damage and re hazard; while hoods  
mounted too high will be hard to reach and will  
lose its performance and efciency.  
If available, also refer range manufacturer’s height  
clearance requirements and recommended hood  
mounting height above range.  
Min 30" - Max 36"  
AK8800Ax  
36"  
Vertical Ducting:  
8” round minimum (dual blower)  
Horizontal Ducting:  
N/A  
DUCTING  
A minimum of 8” round ducting must be used to  
maintain maximum air ow efciency.  
Always use rigid type metal ducts only. Flexible  
ducts could restrict air ow by up to 50%.  
Also use calculation (on page 5) to compute total  
available duct run when using elbows, transitions  
and caps.  
ALWAYS, when possible, reduce the number or  
transitions and turns. If long duct run is required,  
increase duct size.  
If turns or transitions are required; install as far  
away from hood duct output and as far apart,  
between the two as possible.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING FIRE HAZARD  
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages.  
All exhaust must be ducted to the outside.  
Use metal ductwork only.  
Fasten all connections with sheet metal screws and tape all joints with certied Silver Tape or Duct Tape.  
Some Ducting Options  
side wall cap  
w/ gravity damper  
side wall cap  
w/ gravity damper  
Soffit or crawl space  
Roof Pitch w/  
Flashing & Cap  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
316 High Class Stainless Steel Body for AK8800AS  
11 7/16”  
1 3/4”  
C
L
elec  
k/o  
1 1/2”  
14 11/16”  
C
L
11 7/16”  
6 1/2”  
13/16”  
elec.  
k/o  
15 13/16”  
1 1/2”  
1 5/16”  
2 5/8”  
14 11/16”  
15 13/16”  
top  
side  
24 5/8”  
14 3/4”  
7
3/4”  
5”  
11 7/16”  
4
3/8”  
4 3/4”  
2 3/8”  
25 15/16”  
29 13/16”  
front  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTRICAL  
WARNING  
All Electrical work must be performed by qualied electrician or person with similar technical know  
how and background.  
For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use  
extension cord or adapter plug with this appliance.  
Follow national electrical codes or prevailing local codes and ordinances.  
Electrical Supply:  
This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly grounded  
branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire w/  
ground. Please also refer Electrical Diagram labeled on product.  
Cable Lock:  
A cable locking connector (not supplied) might also be required by local codes. Check with local requirements  
and codes, purchase and install appropriate connector if necessary.  
Cable Lock  
!
CAUTION: The power cable must be a GFCI protected branch circuit.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
!
CAUTION: At least two installers are  
required due to the weight and size of the  
hood.  
Remove support screw from top of Power Pack  
before installing into cabinet. FIG 2b  
AK8800Ax  
26 1/16”  
C/L  
1. Place 8” round adapter on top of power pack and secure with (4)  
M4x8 screws. (FIG 3)  
C/L  
2. Install optional AK088xAS Stainless Steel Liner under custom hood  
opening. Review manual included with liner for more details.  
3. If no liner is used cut out an opening in the bottom of the cabinet by  
following the dimensions in (FIG 1).  
cabinet bottom cut-out size  
FIG 1  
5. Lift Power Pack into opening and secure to bottom of cabinet using  
(4) M4 stainless steel screws, (1) in each corner; see (FIG 2).  
NOTE: Wood blocking may need to be added to cabinet base if  
additional support is needed.  
Ductwork  
elec.  
6. Install 8” round duct work and seal with duct tape. Depending on  
the contruction of the custom hood, the duct work may need to be  
installed on top of the Power Pack prior to mounting the Power Pack  
inside your custom hood.  
minimum  
3/4” wood base  
Front View  
7. Install electrical.  
metal or other non  
combustible material  
(4) M4 ss wood screws  
(1) in each corner  
8. Remove all packing materials before using Power Pack.  
Switch power on and check for leaks around duct tape.  
FIG 2  
remove support screw  
FIG 2b  
FIG 3  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1 Lights On/Off  
2
Adjust Blower Level (2 Speeds)  
1
2
Light On/Off  
By pressing  
, the light is switched On and Off. is on,  
is off.  
Blower Speed Selection  
The 2 speed levels are selected by switching to  
for level one and  
for level two.  
Switching the rocker switch to middle  
will turn off the blower.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
!
CAUTION: If this hood is installed in a salt water area (example: coast),  
rinse all surfaces once a week with clear water (even if the hood is not used), and wipe dry completely.  
SURFACE MAINTENANCE:  
Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent,  
or steel wool/ scoring pads which will scratch and damage surface. Do not use products containing chlorine  
bleach or orange cleaners.  
For heavier soil use liquid degreaser.  
After cleaning, you may use non-abrasive stainless steel polish/ cleaners, to polish and buff out the stainless  
luster and grain. Always scrub lightly using a micro ber or clean cotton cloth and with the grain.  
Bafe Filters  
The lters are intended to trap residue and grease from cooking. Although the lters should never need  
replacing, they are required to be cleaned every 30 days or more often depending on cooking habits.  
Filters may be placed in dishwasher at low heat or soaked in hot soapy water Dry lters and re-install before  
using hood.  
Installing Bafe Filters (FIG 4):  
1. Place lter into top groove of the power pack as shown and  
pull towards front of power pack using handles.  
2. Pivot back of lter upwards so it is angled in the power pack.  
1
3. Push lter into channel on back of power pack to lock into place.  
3
Replacing/Ordering Bafe Filters:  
2
Hood Model:  
Part No.  
Qty. to Order  
AK8800Ax  
50210010  
2
FIG 4  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
REPLACING LIGHT BULBS  
CAUTION: Light bulb becomes extremely hot when turned on.  
DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns.  
Make sure all power is turned off and bulbs are not hot.  
Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, stops and  
falls out.  
If bulbs are difcult to turn due to prolonged use, rmly attach a glass suction cup approximately the  
diameter of the bulb or use a rubber/latex glove and turn counter clockwise.  
Replacement bulbs are available at specialty lighting stores. Purchase type MR16 (GU-10) 35W halogen.  
For Zephyr part numbers please turn to page 15 of the manual.  
Bottom View  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING PROCEDURES FOR WILLOW  
Issue  
Cause  
What to do  
After installation, 1. The power source is not turned ON.  
the unit doesn’t  
1. Make sure the circuit breaker and the unit’s  
power is ON.  
work.  
2. The power line and the cable locking connector  
2. Check the power connection with the unit is  
connected properly.  
is not connecting properly.  
3. The switch board and control board wirings are  
disconnected.  
3. Make sure the wirings between the switch  
board and control board are connected  
properly.  
4. The wires on control board are loose.  
4. Make sure the wires on the control board are  
connected properly.  
5. The switch board or control board is defective.  
5. Change the switch board or control board.  
1. Change the motor.  
Light works,  
but motor is not  
turning.  
1. The motor is defective, possible seized.  
2. The thermally protected system detects if the  
motor is too hot to operate and shuts the motor  
down.  
2. The motor will function properly after the  
thermally protected system cool down.  
3. Damaged capacitor.  
3. Change the capacitor.  
4. The motor wire is not connected.  
4. Make sure the motor wire is plugged into the  
molex connector.  
The unit is  
vibrating.  
1. The motor is not secure in place.  
2. Damaged blower wheel.  
1. Tighten the motor in place.  
2. Change the blower.  
3. The hood is not secured in place.  
1. Defective halogen bulb.  
3. Check the installation of the hood.  
1. Change the halogen bulb.  
2. Tighten the light bulb.  
The motor is  
working, but the  
lights are not.  
2. The light bulb is loose.  
3. The wires on the control board are loose.  
3. Make sure the wires on control board are  
connected properly.  
The hood is  
not venting out  
properly.  
1. The hood might be hanging too high from the  
cook top.  
1. Adjust the distance between the cook top and  
the bottom of the hood within 26” and 36”  
range.  
2. The wind from the opened windows or opened  
doors in the surrounding area are affecting the  
ventilation of the hood.  
2. Close all the windows and doors to eliminate  
the outside wind ow.  
3. Blockage in the duct opening or duct work.  
3. Remove all the blocking from the duct work or  
duct opening.  
4. The direction of duct opening is against the wind. 4. Adjust the duct opening direction.  
5. Using the wrong size of ducting.  
1. Metal lter is loose.  
5. Change the ducting to correct size.  
1. Change the metal lter.  
Metal lter is  
vibrating.  
2. Spring clip is broken.(bafe lter)  
1. Battery is dead  
2. Change the spring clip.  
RF Remote  
control does not  
work  
1. Replace battery with type A23 12v  
2. Poor communication with the power pack  
2. Remote control must be within 15 ft of power  
pack  
3. RF remote lost communication with power pack  
3. Reset power pack and remote by switching  
power off at the circuit breaker for 5 minutes.  
Pace remote on counter top near power pack  
and switch the circuit breaker back on.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESCRIPTION  
PART #  
Replacement Parts  
Light Bulb MR16 (GU10) 35W (each)  
Bafe Filter (each)  
Z0B-0023  
50210010  
Optional Accessories  
Liner, 36”  
Liner, 42”  
Liner, 48”  
Liner, 54”  
Liner, 60”  
AK0886AS  
AK0882AS  
AK0888AS  
AK0884AS  
AK0880AS  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  

West Bend Griddle 76225 User Manual
Westinghouse Flat Panel Television UW40T User Manual
Whirlpool Freezer EV161FZRQ02 User Manual
Whirlpool Router 690LR User Manual
White Outdoor Snow Blower 1150W User Manual
Xtant Work Light X21204 User Manual
Yamaha Stereo Amplifier CP2000 User Manual
Zanussi Clothes Dryer TD30 User Manual
Zanussi Freezer 113186 User Manual
Zanussi Washer FJ 1033 User Manual