INSTALLATION INSTRUCTIONS  
MODEL 490-95  
MICRO LINK™ “PLASMA FRIENDLY” INFRARED RECEIVER  
TABLE OF CONTENTS  
INTRODUCTION ............................................................................................................................................................. 1  
Features...................................................................................................................................................................... 1  
Specifications .............................................................................................................................................................. 1  
INSTALLATION ............................................................................................................................................................... 2  
Placement ................................................................................................................................................................... 2  
Mounting...................................................................................................................................................................... 2  
Application Wiring........................................................................................................................................................ 3  
Advanced Wiring Configuration.................................................................................................................................... 3  
3.5mm Mini Plug Pinout ............................................................................................................................................... 4  
INTRODUCTION  
The 490-95 is designed to reject interference from Plasma Displays from entering the IR signal line. These Small IR  
Receivers are intended to be mounted in panels, doors, cabinets, etc. for control of A/V equipment behind closed doors or  
any IR Repeater System that is in close proximity of a Plasma or LCD Displays. Modeled after the original 490-90, the  
490-95 offers the same features as its predecessor but in a smaller mounting frame.  
FEATURES  
Small size; mounts in ¾” diameter hole. 2¾ inches deep (70mm)  
Quick-Connect 3.5mm Stereo Mini Plug on 7ft. (213.36cm) cable for direct plug-in to Xantech Connecting Blocks  
Works in normal 3-wire mode (12VDC, IR, GND)  
Green Talkback LED for System Verification  
Improved Fluorescent Light rejection (under most conditions) and rejection from LCD Displays  
Can be used in Direct Sunlight  
RF Grid included for EMI interference reduction  
Includes CB12 Connecting Block for easy connection and extension of 7' ribbon cable  
7 units may be powered by one 781RG power supply  
Note: The 490-95 will not operate in 2-wire Phantom Power mode  
SPECIFICATIONS  
Infrared modulation frequency bandwidth: 30 - 100 kHz  
Reception range: up to 55 feet (17M), depending on local conditions  
Reception angle: 55 degrees off axis for 50% range reduction  
Cable requirements: 3-conductor. Use 24 gauge up to 200' (61M), 22 gauge up to 600' (182.5M), 20 gauge up to  
1000' (305M), 18 gauge up to 2000' (610KM) -- unshielded OK)  
Maximum transmission length: One mile using 18 gauge wire (1.6KM)  
Maximum current output: 100 mA  
Dimensions: 0.75" diameter x 2.75" deep (19mm x 70mm)  
Power requirements: 12 volts DC @ 20 mA  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 490-95  
Page 3  
APPLICATION WIRING  
A typical system, with a 490-95, 781RG Power Supply and 283M Emitter plugged into a 789-44 Connecting Block, is  
shown in Figure 3:  
1. Plug in the 2.1mm Coaxial power plug of the 781RG Power Supply (not included) into the jack labeled 12VDC on  
the 789-44 Connecting Block.  
2. Plug the AC end of the 781RG power Supply into an ‘un-switched’ 120v AC Line outlet.  
3. Plug the 3.5mm stereo mini plug from the 490-95 into the IR RCVR input on the 789-44 Connecting Block  
4. Plug in the Emitters 3.5mm mono mini plug such as any of the 282, 284, 283 and 286 series into the jacks labeled  
EMITTERS on the 789-44 and affix the opposite end to the IR Sensor Window of the controlled equipment.  
781RG  
Satellite Receiver  
Power Supply  
To 120 VAC  
(unswitched)  
283M Emitter  
490-95  
Micro Link  
789-44  
Connecting Block  
VCR  
Plasma-Friendly  
IR Receiver  
Hand Held  
Remote  
283M Emitter  
+12 VDC  
AV Receiver  
GND  
STATUS  
IR IN  
283M Blink-IR™  
Mouse Emitter  
Equipment Rack  
Figure 3 - Typical System Layout using 490-95, 789-44, 781RG, and 283M Emitters  
ADVANCED WIRING CONFIGURATION  
490-95 may also be used where the 7-foot lead is not long enough. In this case, simply use the CB12 Connecting Block  
as a “break-out” block. In Figure 4, a 490-95 is extended down to a 789-44 Connecting Block and combined with other  
Xantech IR Receivers.  
1. Plug the 3.5mm stereo mini plug from the 490-95 into the IR RCVR input on the CB12 Connecting Block.  
2. Using 3-Conductor wire (refer to Specifications section for proper Wire Gauge) connect the terminals labeled V  
G S of the CB12 to the terminals labeled +12VDC, GND, and IR IN on the 789-44 Connecting Block (or other)  
3. Plug in the 2.1mm Coaxial power plug of the 781RG (or 782) Power Supply (not included) into the jack labeled  
PWR on the 789-44CB.  
CAUTION! Do not plug in a 781RG or any other Power Supply into the CB12 when using in a “break-out”  
configuration. This will put 2 supplies in parallel and possibly damage your equipment. If a ‘local’ emitter is needed on  
the CB12, see Step 5 below.  
4. Plug in the Emitters 3.5mm mono mini plug such as any of the 282, 284, 283 and 286 series into the Emitter  
Outputs on the 789-44.  
© 2004 Xantech Corporation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Page 4  
Model 490-95  
ROOM 2  
ROOM 3  
ROOM 4  
GND  
+12V  
3-Wire  
Cable  
490-95  
Plasma-Friendly  
IR Receiver  
480-00  
Dinky Link™  
IR Receiver  
Hand Held  
Remote  
780-10  
J-Box  
IR Receiver  
Red  
Stripe  
IR OUT  
+12V  
(See Text)  
+12 VDC  
X
X
IR OUT  
O U T  
P W R CB12  
IR OUT  
GND  
Connecting  
Block  
GND  
To 120 V AC  
(unswitched)  
Satellite Receiver  
782-00  
Power  
Supply  
Smart  
Pad™  
282M  
Mouse Emitter  
789-44  
V
G
S
VCR  
Connecting Block  
282M  
Emitter  
AV Receiver  
+12 VDC  
GND  
STATUS  
IR IN  
283M  
Blink IR Emitter  
3-Conductor Room-to-Room Cable  
24 to 18 gauge (unshielded OK)  
286M  
Dual Blink IRs  
(to other  
controlled  
devices)  
291-10  
IR Receiver  
MAIN ROOM 1, EQUIPMENT CABINET, ETC.  
Figure 4 - Advanced Wiring Configuration using 490-95, CB12, 789-44, 781RG and multiple 286M’s  
5. If a local Emitter is needed on the CB12, you will need to place a 470 Ohm Resistor in Series with the Signal  
Output on the CB12. To Wire in this fashion:  
a. Cut a standard Mouse Emitter (282M or 283M) approximately 12inches from the 3.5mm Mono Mini Jack.  
You will now have 2 cables; one with a 3.5mm Mono Mini Jack and one with the Mouse Emitter.  
b. Wire the 2 leads of the Mono Mini Jack side to a terminal Strip.  
c. On the Terminal Strip, opposite the lead with the White Stripe (Signal) connect one side of the 470 Ohm  
Resistor.  
d. Wire the other side of the resistor to the lead with the White Stripe on the Mouse Emitter.  
e. Connect the Black Wire of the Mouse Emitter to the Terminal Strip opposite the Black Wire (GND) from  
the 3.5mm Mono Mini Jack.  
This will keep the proper load balance and prevent miscommunication with the Emitters on the 789-44 CB.  
3.5MM MINI PLUG PINOUT  
There might be times when the 490-95 needs to be wired directly to a Terminal Block. In that case you will need to cut off  
the 3.5mm jack and wire according to Table 1.  
Table 1 - 490-95 Connector Pin-Out  
PLUG  
CABLE LEADS CIRCUIT ITEM  
TIP  
WHITE  
BLACK  
RED  
IR OUT  
GROUND  
+12V  
RING  
SLEEVE  
CAUTION: With any of these systems, be sure the 781-RG Power Supply is plugged into an un-switched AC outlet. This  
maintains the 490 system in "stand-by" operation so that power-on commands can be sent to the controlled equipment.  
XANTECH CORPORATION  
13100 Telfair Avenue, Sylmar CA 91342-3829  
phone 818.362.0353 • fax 818.362.9506  
Part No. 08901485 Rev A 07-22-04  
© 2004 Xantech Corporation  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Weider Cash Register XE A101 User Manual
Weider Home Gym WEBE06110 User Manual
Whirlpool Air Conditioner ACH082XD0 User Manual
Whistler Radar Detector XTR 185 User Manual
Worksaver Compact Loader DCR 4 User Manual
ZALMAN Computer Hardware GV1000 User Manual
Zanussi Dishwasher 534324 User Manual
Zanussi Oven BMS 641 BST 6 User Manual
Zanussi Washer ZWH6100 P User Manual
Zebra Technologies Printer Q3DLUBA000002 User Manual