X10 Wireless Technology Switch XPS2 User Manual

240V Wall Switch - Receiver  
XPS2  
Code  
Dials  
Double-Pole Switch  
GROUND (GREEN)  
LINE (BLACK)  
LINE (RED)  
LOAD (BLUE)  
LOAD  
240V  
Double  
Breaker  
Motor, Pump  
Vac, Heater  
Blower  
240V / 20A  
LOAD (YELLOW)  
HID Lights  
etc.  
Rocker  
Plate  
XPS2  
Description:  
The XPS2 is a 240V, Decorative-style, non-dimming, Double-Pole Wall Switch rated for 20Amps. It can handle ON/OFF loads as follows:  
Pumps, Air Conditioners, HID Lighting, Blowers, Heaters, Vacuum Systems, etc. It's decorative rocker plate permits local operation of the switch.  
The X10 Address Code Dials set House Code and Unit Number and are located behind the Rocker Plate.  
Specific Requirements: 240VAC, 20Amps  
Optional / Supplementary Devices & Modules:  
XPF - Load-side Filter (one on each leg) to reduce noise, from load, degrading switch remote operation.  
PMC01 Desk-top, Mini-Controller, XPMT1 Desk-top Mini-Timer, PHK05 Wireless RF Handheld Remote Kit  
X10 Protocol:  
House Code Dial - Letters A-P (default "A") Unit Number Dial - Numbers 1-16 (default "1")  
Each X10 Receiver Module is set to a unique Unit Number or to an identical Unit Number as desired.  
Each X10 Controller operating a specific set of Receiver Modules must be set to the same House Code as the Receivers they are controlling.  
Does NOT respond to ALL Lights ON  
Electrical Protocol:  
Nearly all residential homes are wired SPLIT-PHASE. Each 120V Phase is NOT directly connected with the other 120V phase. If after installation,  
an X10 Receiver does not respond to a remote Controller, then check to ensure that the breaker serving the X10 Receiver is on the same phase as  
the Controller. If not, the breaker can be changed to the opposite phase. An alternative solution is recommended, to install a Phase Coupler for  
improving remote communications throughout the home. See www.x10pro.com, then select Technical Support and PLC Troubleshooting.  
Installation:  
1. Turn power OFF at Circuit Breaker  
2. Remove the existing wall switch. Five wires remain protruding out of switch box. Two wires are HOT (one from each phase of a 120/240  
electrical system), two wires go to the LOAD and one wire is Green which is Ground. Spread wires apart so none are touching each other.  
3. With Breaker ON, determine which two protruding wires are HOT. Use a voltmeter and measure between ground and each wire, individually.  
Two will read 120V (LINE), the other two are 0V to (LOAD). One is the Green Ground wire. You will measure 240V across the two HOT wires.  
4. With the Breaker OFF, Connect the Switch "Green" Ground Wire to the Ground wire in the switch box.  
5. Connect the two HOT wires to the Switch "Red and Black" LINE wires, connect the other two LOAD wires to the  
Switch "Blue and Yellow" LOAD wires.  
7. Re-check all connections, Turn power ON at Circuit Breaker.  
8. Press switch paddle once, you will hear the switch CLICK and the LOAD should turn ON. Press paddle again, you will hear the switch CLICK  
and the LOAD should turn OFF.  
7. Attach the face plate.  
You are now ready to control the switch with an X10 Remote Control Module: desktop, wireless handheld, Security Panel, etc. The default address  
is "A1". If you wish to change the Code, the Code Dials are behind the paddle. Remove the paddle, with a small flat screwdriver, buy prying it up  
from its side center point..  
XPS2_03_03/07  
Technical Support: (800) 832-4003  
Tampa, FL 33542  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Weed Eater Tiller WER500D User Manual
Weslo Treadmill 831295021 User Manual
Western Digital Computer Drive WD10JPVT User Manual
Westinghouse Flat Panel Television vr 2418 User Manual
Whirlpool Clothes Dryer WGD9200SQ1 User Manual
Whirlpool Washer Dryer LMR5243A User Manual
White Westinghouse TV VCR Combo WTV11321B User Manual
Xerox Printer Phaser 6300 6350 User Manual
Yamaha Personal Computer CRW2200S User Manual
Zanussi Refrigerator Z1163 TR User Manual