Wolf Ventilation Hood SRT484CG User Manual

Planning Information  
48" (1219) Sealed Burner Rangetops  
M O D E L S S R T 4 8 6 C  
/
S R T 4 8 6 G  
/
S R T 4 8 4 C G  
/
S R T 4 8 4 D G  
/
S R T 4 8 4 F  
Infrared griddle  
(optional)  
Infrared charbroiler  
(optional)  
Continuous,  
cast iron top grates  
Low-profile  
island trim  
Dual-stacked,  
sealed burners  
Model SRT486C  
Model SRT486G  
Model SRT484CG  
Model SRT484DG  
Model SRT484F  
Stainless steel  
exterior finish  
Griddle indicator  
light  
Control knobs with  
platinum bezels  
Location of rating  
plate  
Model SRT484CG shown  
This appliance is certified by Star-K  
to meet strict religious regulations in  
conjunction with specific instructions  
The Wolf 48" (1219) sealed burner  
rangetop is available in natural or LP gas,  
with your choice of several top configura-  
tions. Model numbers indicate the  
There's a good reason why professional chefs choose  
gas cooking; control. The patented, dual-stacked sealed  
gas burners of our new sealed burner rangetop take  
control to a new level. Two levels, really. The upper-tier  
burner delivers maximum heat transfer at higher settings;  
the lower-tier continuous flame ably handles the  
subtleties of simmering and melting.  
rangetop features; (C) charbroiler, (G)  
griddle, (DG) double griddle and (F) French  
top. The model number followed by (-LP)  
denotes an LP gas model.  
Patented features along with the Wolf exclusive infrared  
charbroiler, infrared griddle and French Top ensure this  
rangetop stands out from the rest in performance and  
also beauty.  
Let Wolf, the corporate companion and kitchen soul mate  
of Sub-Zero, fuel your passion for cooking and kitchen  
design.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
1
5/06  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Planning Information  
48" (1219) Sealed Burner Rangetops  
M O D E L S S R T 4 8 6 C  
/
S R T 4 8 6 G  
/
S R T 4 8 4 C G  
/
S R T 4 8 4 D G  
/
S R T 4 8 4 F  
M O D E L O P T I O N S  
Six Burners/Charbroiler  
Six Burners/Griddle  
S P E C I F I C A T I O N S  
SRT486C  
SRT486G  
Overall Rangetop Width  
477/8" (1216)  
Overall Rangetop Height  
(to cooking surface)  
81/2" (216)  
Four Burners/Charbroiler  
and Griddle  
Overall Rangetop Depth  
281/2" (724)  
SRT484CG  
Four Burners/Double  
Griddle  
Dual-Stacked Sealed Surface Burners  
SRT484DG  
SRT484F  
15,000 Btu/hr (4.4 kW) burners with 950 Btu/hr  
(.3 kW) delivered at simmer  
Single 9,200 Btu/hr (2.7 kW) burner with 325 Btu/hr  
(.1 kW) delivered at simmer  
Four Burners/French Top  
Natural gas model listed, for LP gas add  
(-LP) to the model number.  
Infrared Charbroiler  
16,000 Btu/hr (4.7 kW)  
V E N T I L A T I O N O P T I O N S  
48" (1219) Pro wall hood or liner  
54" (1372) Pro wall or island hood  
Infrared Griddle – Natural Gas  
LP Gas  
15,000 Btu/hr (4.4 kW)  
13,000 Btu/hr (3.8 kW)  
Double Griddle (two burners)  
Natural Gas  
LP Gas  
15,000 Btu/hr (4.4 kW)  
13,000 Btu/hr (3.8 kW)  
Refer to the Wolf Pro Ventilation section  
of our website, wolfappliance.com for  
additional information.  
French Top  
15,000 Btu/hr (4.4 kW)  
Electrical Supply Requirements  
110/120 V AC, 50/60 Hz  
15 amp dedicated circuit  
A C C E S S O R I E S  
Power Cord  
6' (1.8 m) power cord with  
3-prong grounded plug  
5" (127) or 10" (254) classic  
stainless steel riser  
Shipping Weight  
240 lbs (109 kg) – 280 lbs (127 kg)  
20" (508) classic stainless steel  
riser with shelf  
Specifications are subject to change without notice.  
Black control knobs  
IMPORTANT NOTE: A minimum 10" (254) riser is required for  
charbroiler (C) or griddle (G) models installed against a combustible  
surface.  
Chrome or brass bezels  
One-piece wok grate and single  
burner grate  
Porcelain-coated cast iron two-  
burner S-grate  
Hardwood cutting board (griddle  
models only)  
High altitude conversion kits  
Accessories are available through  
your Wolf dealer. To obtain local dealer  
information, visit the Locator section  
of our website, wolfappliance.com.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Planning Information  
48" (1219) Sealed Burner Rangetops  
I N S T A L L A T I O N  
VENTILATION HOOD  
36"min (914)  
COUNTERTOP  
TO COMBUSTIBLE  
MATERIALS  
13" max  
(330)  
30"min (762) TO  
6"min (152)  
TO  
44"min (1118)  
36"max (914)  
TO BOTTOM OF  
18"min (457)  
FOR CHARBROILER  
TO COUNTERTOP  
COMBUSTIBLE  
MATERIALS  
(BOTH SIDES)  
VENTILATION HOOD  
COOKING  
SURFACE  
1
8 /2"  
48" (1219)  
1
7 /2"  
(216)  
FINISHED ROUGH OPENING WIDTH  
3
(191)  
3
/4" (19) PLATFORM  
/4" (19)  
16" (406)  
36"  
PLATFORM  
(914)  
LOCATION OF GAS AND  
ELECTRICAL SUPPLY CUT-OUT  
WITHIN SHADED AREA  
THROUGH BOTTOM OF  
PLATFORM  
TOP VIEW  
24" (610)  
OF PLATFORM  
BACK  
4" (102)  
WALL  
E
G
16"  
(406)  
ISLAND INSTALLATIONS: 12" (305) MINIMUM  
CLEARANCE FROM BACK OF RANGETOP TO  
COMBUSTIBLE REAR WALL ABOVE COUNTERTOP–  
0" (0) TO NON-COMBUSTIBLE MATERIALS  
D I M E N S I O N S  
Rough Opening Width  
Rough Opening Height  
Rough Opening Depth  
48" (1219)  
71/2" (191)  
24" (610)  
Location of Electrical and Gas Supply  
See Installation Instructions shipped with unit for detailed specifications.  
Within shaded area  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Planning Information  
48" (1219) Sealed Burner Rangetops  
I N S T A L L A T I O N  
I N S T A L L A T I O N N O T E S  
Refer to the illustrations and specifications  
for overall dimensions, finished rough opening  
dimensions and installation specifics.  
Wolf sealed burner rangetops are designed  
to operate on natural gas at 5" (12.5 mb) WC  
(water column) pressure or LP (propane) gas at  
10" (25 mb) WC pressure. The minimum line  
pressure for natural gas is 7" (17.5 mb) WC and  
11" (27.4 mb) WC for LP gas. The maximum  
gas supply pressure to the regulator should  
never exceed 14" (34.9 mb) WC; .5 psi (3.5  
kPa).  
IMPORTANT NOTE: Caution must be used in  
planning the proper installation of the Wolf  
sealed burner rangetop to avoid any fires or  
damage to adjacent cabinetry or kitchen equip-  
ment. Follow the minimum clearances estab-  
lished in the finished rough opening dimensions  
as shown in the Installation illustration.  
If local codes permit, a certified, 3' (.9 m)  
long, 1/2" or 3/4" ID flexible metal appliance  
connector is recommended for connecting the  
rangetop to the gas supply line.  
The platform for the rangetop must be 3/4"  
(19) thick and include a cut-out at the right rear  
for gas supply and electrical connections. The  
platform must be level to ensure that the  
cooking surface is level.  
IMPORTANT NOTE: A separate external gas  
shut-off valve must be located near the  
rangetop in an accessible location.  
IMPORTANT NOTE: A minimum 10" (254) riser  
is required for charbroiler (C) or griddle (G)  
models installed against a combustible surface.  
Wolf sealed burner rangetops using natural  
gas will operate up to an altitude of 8,000'  
(2438 m) without any adjustment. Natural gas  
and LP gas installations from 8,000' (2438 m)  
to 11,000' (3353 m) need the high altitude  
conversion kit. Contact your Wolf dealer for  
details. To obtain local dealer information, visit  
the Locator section of our website, wolfappli-  
ance.com.  
It is recommended that you use a Wolf Pro  
wall or island ventilation hood or hood liner  
with the Wolf sealed burner rangetop. Refer to  
the Pro Ventilation section of our website,  
wolfappliance.com.  
The Wolf sealed burner rangetop requires a  
110/120 V AC, 50/60 Hz electrical supply to  
operate the electronic ignition system. The  
power supply cord is equipped with a 3-prong,  
grounded plug for protection against shock  
hazard. The service should have its own 15  
amp circuit breaker. Locate electrical and gas  
supply within the shaded area shown in the  
Installation illustration.  
You must follow all National Electrical Code  
and gas regulations. In addition, be aware of  
local codes and ordinances when installing your  
services.  
Refer to the installation instructions  
shipped with each Wolf product for detailed  
specifications.  
IMPORTANT NOTE: A ground fault circuit  
interrupter (GFCI) is not recommended and may  
cause interruption of operation.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  

Westinghouse Flat Panel Television LD 265 User Manual
Whirlpool Ventilation Hood GZ8330XLS0 User Manual
Whirlpool Washer Dryer LE5200XT, LE5750XM, LE5790XS, LE5795XP, LG5201XT, LG5751XM, LG5791XS, LG5796XP User Manual
White Outdoor Lawn Mower ZT 1850, ZT 2150, ZT 2250 User Manual
White Rodgers Thermostat 1F56N 911 User Manual
Xerox Printer WC PE120 Series User Manual
Zanussi Clothes Dryer TC 482 W User Manual
Zanussi Fryer 200224 User Manual
Zanussi Ventilation Hood 641249 User Manual
Zanussi Washer DL 22 User Manual