Wolf Appliance Company Ventilation Hood PW302210R User Manual

Planning Information  
Pro Low-Profile Wall Ventilation Hood  
M O D E L P W 3 0 2 2 1 0 ( R )  
Hand finished  
craftsmanship  
Classic stainless  
steel finish  
Stainless steel  
baffle filters  
Decorative rail  
(optional)  
Model PW302210  
Location of  
rating plate  
Model PW302210R  
Rail Option  
Welded seams  
and hemmed edges  
Recessed easy-  
access controls  
Halogen lighting  
Infinite-speed  
blower control  
Model PW302210R shown with decorative rail.  
Wolf Pro wall hoods provide the ultimate in  
ventilation. With standard elements like heat sentry  
and dual setting halogen lighting, Wolf elevates the  
need for ventilation to an enjoyable perk.  
Wolf Pro low-profile wall hoods are  
10" (254) high by 22" (559) deep and  
come in the classic stainless steel finish.  
Rail option hoods (R) come with a classic  
stainless steel decorative rail and stand-  
offs. Optional platinum or brass rails  
match dual fuel range bezels. Pro wall  
hoods are sold as a shell only; internal,  
in-line and remote blower options are  
available.  
Pro low-profile wall hoods are available in the classic  
stainless steel finish. You also have the option of a  
decorative rail. While a classic stainless steel rail is  
standard on (R) models, platinum or brass rails are  
available to match the bezels of our dual fuel ranges  
and sealed burner rangetops.  
Pro wall ventilation hoods are recommended for use  
with all Wolf cooking appliances. For optimal perform-  
ance, a Pro 27" (686) deep wall hood is recommended  
for use with ranges and rangetops that contain a  
charbroiler or griddle.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
1
9/07  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Planning Information  
Pro Low-Profile Wall Ventilation Hood  
M O D E L P W 3 0 2 2 1 0 ( R )  
B L O W E R O P T I O N S  
500 CFM Internal Blower  
600 CFM In-Line Blower  
600 CFM Remote Blower  
900 CFM Remote Blower  
S P E C I F I C A T I O N S  
810991  
808331  
801640  
801641  
Overall Width of Hood  
Overall Height of Hood  
30" (762)  
10" (254)  
Overall Depth of Hood  
(including rail)  
22" (559)  
24" (610)  
Internal Blower Option  
In-Line Blower Option  
Remote Blower Options  
Discharge  
500 CFM  
600 CFM  
Refer to Pro Ventilation Recommendations  
at the end of this section.  
600 or 900 CFM  
Vertical or Horizontal  
10" (254) Round  
A C C E S S O R I E S  
Platinum or brass decorative rail  
and stand-offs  
Duct Size  
Electrical Supply Requirements  
110/120 V AC, 60 Hz  
15 amp dedicated circuit  
38" (965) high classic stainless  
steel backsplash with or without  
warming racks  
Shipping Weight (shell only)  
59 lbs (27 kg)  
6" (152), 12" (305), 18" (457) and  
24" (610) classic stainless steel  
duct covers  
Specifications are subject to change without notice.  
Transitions for both 8" (203) and  
10" (254) round duct  
Recirculating kit  
Accessories are available through your  
Wolf dealer. To obtain local dealer  
information, visit the Showroom Locator  
section of our website, wolfappliance.com.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Planning Information  
Pro Low-Profile Wall Ventilation Hood  
M O D E L P W 3 0 2 2 1 0 ( R )  
I N S T A L L A T I O N S P E C I F I C A T I O N S  
LOCATION OF  
ELECTRICAL  
6"  
E
(152)  
5"  
10" (254)  
HEIGHT  
(127)  
OF HOOD  
30" (762)  
WIDTH OF HOOD  
30" TO 36"  
(762–914)  
30" TO 36"  
(762–914)  
22" (559)  
DEPTH OF HOOD  
TO COUNTERTOP  
TO COUNTERTOP  
NOTE: Pro low-profile hoods have an adjustable discharge.  
D I M E N S I O N S  
Overall Width of Hood  
30" (762)  
Overall Height of Hood  
10" (254)  
22" (559)  
Overall Depth of Hood (excluding rail)  
Countertop to Bottom of Hood  
Location of Electrical  
30" (762) to 36" (914)  
Within shaded area  
See Installation Instructions shipped with unit for detailed specifications.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Planning Information  
Pro Low-Profile Wall Ventilation Hood  
M O D E L P W 3 0 2 2 1 0 ( R )  
I N S T A L L A T I O N N O T E S  
Refer to the illustrations and specifications  
IMPORTANT NOTE: Install this ventilation hood  
for overall dimensions and installation specifics.  
only with a Wolf blower.  
Wolf Pro wall ventilation hoods are recom-  
mended for use with any Wolf cooking appli-  
ance, and should be as least as wide as the  
cooking surface. It is recommended that the  
hood overlap the cooking surface by 3" (76) on  
either side.  
Pro wall hoods require a separate, grounded  
110/120 V AC, 60 Hz power supply. The service  
should have its own 15 amp circuit breaker.  
Placement of the electrical supply is not critical,  
as long as you provide enough 120 V AC, 60 Hz  
power cable to make the electrical connection.  
Locate electrical within the shaded area shown  
in the Installation illustration on page 4.  
IMPORTANT NOTE: For optimal performance, a  
Pro 27" (686) deep wall hood is recommended  
for use with ranges and rangetops that contain  
a charbroiler or griddle.  
You must follow all National Electrical Code  
regulations. In addition, be aware of local codes  
and ordinances when installing your service.  
Installation of all Pro ventilation hoods  
should be 30" (762) to 36" (914) from the  
bottom of the hood to the countertop. Follow  
the dimensions shown in the Installation  
illustration on page 4.  
Refer to the installation instructions shipped  
with each Wolf product for detailed specifica-  
tions. This information can also be found on  
our website, wolfappliance.com.  
Wolf Pro wall hoods are shipped without a  
blower assembly. Internal, in-line or remote  
blower assemblies are available. Blower options  
also vary with the volume of air that needs to  
be moved and the length of the duct run. Refer  
to the charts at the end of this section for Pro  
ventilation recommendations and blower  
options.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Planning Information  
Pro Low-Profile Wall Ventilation Hood  
M O D E L P W 3 0 2 2 1 0 ( R )  
D U C T I N G C O N S I D E R A T I O N S  
Wolf Pro low-profile wall hoods are shipped  
without the blower assembly. Internal, in-line  
and remote blower assemblies are available.  
The hood will operate most efficiently when  
ductwork does not exceed 50' (15 m) in length.  
Local building codes may require the use of  
make-up air. Consult your local HVAC professional  
for specific requirements in your area.  
IMPORTANT NOTE: Install this ventilation hood  
only with a Wolf blower.  
Pro low-profile wall hoods come standard with  
a horizontal or vertical discharge. No transition is  
included. Internal blower WBLOWER-50INT  
comes with a transition. When using an in-line  
or external blower, use the optional accessory  
10" (254) round transition.  
IMPORTANT NOTE: Wolf Pro low-profile wall  
hoods must be vented to the outside except when  
used with the accessory recirculating kit with the  
600 CFM blower. Use only metal ductwork.  
Refer to the illustration below for ducting  
considerations for Pro low-profile wall hoods.  
Ducting for Pro  
low-profile wall hoods.  
DUCTWORK INSTALLATION  
THROUGH ROOF  
ROOF CAP OR REMOTE BLOWER  
10" (254) ROUND DUCT  
ACCESSORY TRANSITION  
FOR IN-LINE OR  
SOFFIT OR CABINET  
OR DUCT COVER  
REMOTE BLOWER  
173/4"W x 41/4"D TO 10" ROUND  
93/8"H (INCLUDING FLANGES)  
VERTICAL DISCHARGE  
10" (254)  
HEIGHT OF HOOD  
WALL HOOD  
22" (559)  
DEPTH OF HOOD  
30" TO 36"  
(762–914)  
COUNTERTOP  
TO BOTTOM OF  
VENTILATION HOOD  
36" (914)  
STANDARD  
FLOOR TO  
COUNTERTOP  
HEIGHT  
NOTE: 10" (254) ROUND ACCESSORY TRANSITION SHOWN IN VERTICAL DISCHARGE APPLICATION WITH  
IN-LINE OR REMOTE BLOWER. REFER TO INSTALLATION INSTRUCTIONS FOR HORIZONTAL DISHCARGE.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Planning Information  
Pro Low-Profile Wall Ventilation Hood  
M O D E L P W 3 0 2 2 1 0 ( R )  
W O L F B L O W E R A S S E M B L I E S  
A ventilation system must include a blower  
assembly. Wolf ventilation hoods are shipped  
without the blower assembly. An internal, in-line  
or remote blower assembly must be selected to  
accommodate the cooking appliance, CFM  
requirements and homeowner preferences.  
Internal, in-line and remote blower assemblies  
are available as sales accessories through your  
Wolf dealer.  
Internal blowers are mounted inside the hood  
canopy. In-line blowers are mounted in between  
the hood and the exterior of the home. Remote  
blowers can be mounted on the roof or in some  
cases, on an exterior wall. Refer to the illustra-  
tions below for dimensions of Wolf in-line and  
remote blowers.  
Pro ventilation recommendation charts on the  
following page provide minimum CFM recom-  
mendations according to the cooking appliance  
and ventilation hood used and blower options  
for each specific Pro low-profile wall hood.  
IMPORTANT NOTE: Use only a Wolf blower  
with all Wolf ventilation products.  
3
20 /4"  
(527)  
1
3
28 /4"  
24 /8"  
(718)  
(619)  
10" (254)  
Diameter  
3
11 /4"  
1
15 /2"  
(394)  
(298)  
1
24 /2"  
1
(622)  
18 /2"  
(470)  
1
4 /2"  
(114)  
14"  
(356)  
1
21 /2"  
3
4
/4"  
1
(546)  
12 /4"  
(311)  
3
(121)  
24 /4"  
(629)  
In-line BLOWER-60IL  
Remote BLOWER-60REM and  
BLOWER-90REM  
Unit dimensions may vary by 1/8" (3).  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Planning Information  
Pro Low-Profile Wall Ventilation Hood  
M O D E L P W 3 0 2 2 1 0 ( R )  
P R O V E N T I L A T I O N C F M R E C O M M E N D AT I O N S  
Pro Low-Profile Wall Hoods  
Model  
PW302210  
PW362210  
500/600  
900  
PW422210  
PW482210  
DF304 / R304 / SRT304  
DF366 / R366 / SRT366 / RT366  
DF364 / R364 / SRT364 / RT364  
RT362  
500/600  
900  
900  
900  
900  
900  
DF484 / R484 / SRT484 / RT484  
900  
Minimum CFM requirements for Wolf ranges and rangetops. CFM recommendations are based on total Btu/hr output.  
Additional CFM may be required for long duct runs.  
P R O V E N T I L A T I O N B L O W E R O P T I O N S  
Pro Low-Profile Wall Hoods  
Blower Description  
500 CFM Internal  
600 CFM In-Line  
600 CFM Remote  
900 CFM Remote  
Blower Number  
Wall Hood Models  
WBLOWER-50INT (810991)  
BLOWER-60IL (808331)  
BLOWER-60REM (801640)  
BLOWER-90REM (801641)  
PW302210 / PW362210  
All Low-Profile Wall Hoods  
All Low-Profile Wall Hoods  
All Low-Profile Wall Hoods  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  

Weslo Treadmill WCTL293100 User Manual
Whirlpool Cooktop G7CE3055XB User Manual
Whirlpool Garbage Disposal GC1000PE User Manual
Whirlpool Oven R8700PXS User Manual
Williams Sound Stereo Receiver WIR SYS 90V User Manual
Wolf Appliance Company Cooktop CG304P S User Manual
Wolf Range C60CB 10 User Manual
XO Vision Car Video System X348NT User Manual
Yamaha Music Mixer EMX212Ss User Manual
Zanussi Range ZKC6020 User Manual