CARPET EXTRACTOR
Operating Instructions (ENG)
MODEL:
D250 (115V)
Beginning with Serial No. 1000054537
Read these instructions before operating the machine
P
98828 06/07/03
Download from Www.Somanuals.com. All Manuals Search And Download.
SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
When using an electrical appliance, basic precaution
must always be followed, including the following:
READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE.
This machine is for commercial use.
To reduce the risk of fire, electric shock, or injury:
Connect to a properly grounded outlet. See Grounding Instructions.
Do not leave the machine unattended. Unplug machine from outlet when not in use and before
maintenance or service.
Use only indoors. Do not use outdoors or expose to rain.
Do not allow machine to be used as a toy. Close attention is necessary when used by or near
children.
Use only as described in this manual. Use only manufacturer’s recommended components and
attachments.
Do not use damaged electrical cord or plug. Follow all instructions in this manual concerning grounding
the machine. If the machine is not working properly, has been dropped, damaged, left outdoors, or
dropped into water, return it to an authorized service center.
Do not pull or carry machine by electrical cord, use as a handle, close a door on cord, or pull cord
around sharp edges or corners.
Do not run machine over cord. Keep cord away from heated surfaces.
Do not unplug machine by pulling on cord. To unplug, grasp the electrical plug, not the electrical cord.
Do not handle the electrical plug or machine with wet hands.
Do not operate the machine with any openings blocked. Keep openings free of debris that may reduce
airflow.
This machine is intended for cleaning carpet only.
Do not vacuum anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
This machine is not suitable for picking up health endangering dust.
Turn off all controls before unplugging.
Machine can cause a fire when operating near flammable vapors or materials. Do not operate this
machine near flammable fluids, dust or vapors.
This machine is suitable for commercial use, for example in hotels, schools, hospitals,
factories, shops and offices for more than normal housekeeping purposes.
Maintenance and repairs must be done by qualified personnel.
If foam or liquid comes out of machine, switch off immediately.
SAVE THESE INSTRUCTIONS
D-250 98828 11/09/00
2
Download from Www.Somanuals.com. All Manuals Search And Download.
GROUNDING INSTRUCTIONS
THIS PRODUCT IS FOR COMMERCIAL USE ONLY.
ELECTRICAL:
The amp, hertz, and voltage are listed on the
PROPER GROUNDING (115V)
Grounding Pin
Metal Screw
data label found on each machine.
Using
voltages above or below those indicated on the
data label will cause serious damage to the
motors.
Grounded
Outlet
Adaptor
Grounded Outlet Box
Fig. B
Tab For Grounding Screw
Fig. A
GROUNDING INSTRUCTIONS:
Adaptor
Fig. C
This appliance must be grounded. If it should
malfunction or break down, grounding provides a
path of least resistance for electric current to
reduce the risk of electric shock. This appliance
is equipped with a cord having an equipment-
grounding conductor and grounding plug. The
plug must be inserted into an appropriate outlet
that is properly installed and grounded in
accordance with all local codes and ordinances.
The D250 is for use on a nominal 115-volt circuit,
and has a grounded plug that looks like the plug
in “Fig. A”. A temporary adaptor that looks like
the adaptor in “Fig . C” may be used to connect
this plug to a 2-pole receptacle as shown in “Fig.
B”, if a properly grounded outlet is not available.
The temporary adaptor should be used only until
a properly grounded outlet (Fig. A) can be
installed by a qualified electrician. The green
colored rigid ear, lug, or the like extending from
the adaptor must be connected to a permanent
ground such as a properly grounded outlet box
cover. Whenever the adaptor is used, it must be
held in place by a metal screw.
NOTE: In Canada, the use of a temporary adaptor is not
permitted by the Canadian Electrical Code
CHEMICALS
Suitable Chemicals
Non-Compatible
Aldehydes
Alkalis
Aromatics Hydrocarbons
SP Butyls
Carbon Tetrachloride
Clorox*
Detergents
Hydroxides
Soaps
Vinegar
Chlorinated Bleaches
Chlorinated Hydrocarbons
Lysol*
Methyl Ethel Ketone (MEK)
Perchorethylene (perc)
Phenolics
Trichlorethylene
D-Limonene
Warning:
The D250IE is for use on a nominal 230-volt
circuit.
Using the incompatible chemicals listed above
will damage the machine. Damages of this
type are not covered under the 6-3-1 warranty.
Carefully read ingredients on manufacturer's
label before using any product in this machine.
ꢀ WARNING:
Improper
connection of the
equipment-grounding conductor can result in a
risk of electric shock. Check with a qualified
electrician or service person if you are in doubt as
to whether the outlet is properly grounded. Do
not modify the plug provided with the appliance -
if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
D-250 98828 04/25/02
3
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATIONS
CARPET INSPECTION:
PROTECT THIS MACHINE FROM
FREEZING.
Determine precisely what areas you are going to
clean. Note problem areas in the carpet or tack
strip. Look for loose carpet, heavily damaged areas,
discolored stains, or grease spots that will require
prespotting. Note the carpet type. Check the
availability of hot water, drains, and suitable
electrical outlets. If the carpet is loose or worn, have
it repaired before attempting to clean it.
EQUIPMENT SET-UP:
1.) Plug power cable from machine into
properly grounded wall outlet.
2.) Turn vacuum motor switch on and off to make
sure there is electrical power at machine.
3.) Connect vac hose to machine. Slide the swivel
cuff over the outlet on the tank.
Plan the cleaning route, work from the most remote
area towards the exit. Try not to travel over the
cleaned areas when getting fresh water or dumping
old. Furniture should be moved out away from the
walls before cleaning. If furniture is moved back in
place before carpet is completely dry, place plastic
or foil protectors under the legs to prevent possible
carpet staining. When possible use a Windblower
(WB3) and open all windows and doors to speed
carpet drying.
4.) Connect the hose set to the machine and
wand. Pull back the knurled collar on the quick
disconnect coupler and push onto the
connection on the chassis. To avoid leaks,
check to be sure a positive connection was
made.
5.) Pour clean, hot water into the solution tank.
To avoid possible tank distortion, water
temperature must not exceed 140 F (60C).
ACCESSORIES:
The D-250 can be used with the following Windsor
equipment: Deluxe Hand Tool (DHT), Pile
6.) Add a non-foaming cleaning solution
Jogger(PJ2A), Standard Floor Wands(SFW, SW,
concentrate, for use in hot water extractors at
the proportions noted on the container (See list
below), into solution tank. NOTE: When using
powder cleaner, pre-mix with hot water in a
clean container before adding to the
solution tank.
SW-PRO, PROW), & Wind Blower carpet
dryer(WB3). Contact an authorized Windsor dealer
for assistance in choosing the right equipment .
GENERAL INFORMATION:
On heavily soiled carpets, or on areas of high
foot traffic, it may be necessary to use a prespray
or traffic lane cleaner applied with a Pro-Spray. Do
not add presprays to the machine's solution tank. If
a spotter is used, follow the manufacturer's
7.) Turn pump and vacuum switch(s) to the on
position. NOTE: Pump may have to be
primed for solution flow. (See Priming the
Pump)
instructions exactly as printed on the label. Remove
the spotter with the floor tool when done, spotter left
in the carpet may bleach or brown it permanently.
8.) Start cleaning.
PRIMING THE PUMP
As the carpet is being cleaned, check to see if
there is foam building up in the recovery bucket.
Add a little defoaming compound to the recovery
tank but never to the solution tank.
1. Connect priming hose to solution output on
machine.
2. Run open end of priming hose to vacuum intake.
3. Turn pump and both vacuums on and seal off
hose going into vacuum in take.
4. Do this for 30 seconds or until pump is putting
out a steady flow of water.
For infrequent use or long periods of
storage, flush the system with a neutralizing
solution of 1 quart white vinegar mixed with 2
gallons hot water. Flush the system with clean
hot water after neutralizing.
For hose fitting lubrication, use a light
silicone lubricant which will not damage o-rings.
D-250 98828 04/08/03
4
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION
3. When cleaning, keep the working opening (wand
mouth) flat on the surface being cleaned. Keep
the wand moving when the valve is open.
4. The shutoff float inside the recovery tank will
impede the vacuum flow when the tank is full.
When this occurs, empty the recovery tank. Do
this by opening the dump valve located at the
back of the machine. NOTE: Dispose of waste in
a proper manner which would not violate any
Local, State or Federal law.
HEATER OPERATION
The disconnect fittings on the
heater will become extremely
hot during operation. Allow sufficient time to
cool, or run solution through the machine with
the heater turned off before disconnecting the or
performing any maintenance on the heater.
Before disconnecting the heater, open wand valve to
relieve the system of all pressure by depressing the
valve trigger.
5. Once the recovery tank has been emptied, you
may once again proceed with cleaning.
Operating Vacuum after shutoff
has activated could draw water
directly into the vac motor. This will cause
damage to the motor, therefore voiding your
warranty.
DO NOT spray water directly on to the heater. To
clean, unplug the unit and wipe with a damp cloth.
Make certain that the solution
tank is filled adequately before
plugging in the machine and heater.
Always test carpet for color
fastness in an inconspicuous
place. Also, to avoid prolonged drying times, do
not spray too much solution in any one area.
1. Plug the machine and heater into separate
grounded circuits. The heater draws 15 amps of
current.
2. Turn the solution pump ON. Turn the heater
switch ON. The solution pump must be turned on
BEFORE the heater is turned on.
SHUT DOWN AND STORAGE
1. Turn Switch OFF. Empty recovery tank
completely and rinse several times to remove
any dirt or debris that may be left behind.
2. Drain any unused cleaning solution from solution
tank and rinse with clean water to remove any
suds left behind by the cleaning chemicals.
NOTE: Dispose of waste in a proper manner
which would not violate any Local, State or
Federal law
3. Run a small amount of clean water through pump
if chemicals were used. This will help insure the
life of your pump.
4. Check the spray jet on the cleaning tool for full
spray pattern and inspect vac head for any
obstructions.
The heater requires about 5-6 minutes to reach
operating temperature, approximately 250°F.
When turning the machine and heater OFF, make
certain that you turn the heater off FIRST.
EMPTYING AND CLEANING
Always use defoamer if
foaming occurs. Foam will
suspend large particles that may damage
vacuum(s) as well as allow liquid into the vacuum
motor(s) without activating the float shutoff.
1. Before proceeding, make certain that the nozzle
is functioning properly.
5. Remove as much moisture from system before
storing in cold climates. Excess water may freeze
during storage and crack internal components,
causing damage to the unit.
a. To check, hold the wand about one foot
above the surface to be cleaned and open
the wand valve. A full spray should be
observed from the nozzle.
Before making any
adjustments or performing any
maintenance to your machine, disconnect the
power cord from the electrical source.
b. If the nozzle is not showing a full spray
pattern, adjust nozzle for proper pattern,
clean, or replace nozzle.
2. Normally, chemical is applied on the push stroke
while vacuuming is done on the pull stroke.
For heavily soiled carpets the hand tool may
be used in the scrubbing manner, applying
chemical in both the push and pull stroke.
ALWAYS FINISH UP AN AREA WITH A VACUUM PULL
STROKE.
D-250 98828 04/08/03
5
Download from Www.Somanuals.com. All Manuals Search And Download.
MAINTENANCE
3.) Check all handles, switches, knobs, electrical
cables and connections on your machine for
damage. If the cable insulation is broken or
frayed, repair or replace it immediately. Don’t
take chances with electrical fire or shock.
4.) Clean out solution tank and remove and clean
solution screen.
DAILY MAINTENANCE:
(At the end of each working day) :
1.)
Flush the entire system, including floor tool,
hand tool, etc., with 1 to 3 gallons of clean,
hot water.
2.)
3.)
Vacuum out the solution tank .
Rinse tank with fresh water. Periodically
inspect the recovery tank and
5.) Clean outside of all tanks and check for
damage.
decontaminate if necessary, using a
Hospital Grade Virucide or a 1-10 bleach to
water solution. Waste water should be
disposed of properly.
Remove lint build-up from the float shut-off
screen in the recovery tank . (Occasionally
check filter screen at the bottom of the
solution tank and rinse clean with hot water
if necessary).
MONTHLY MAINTENANCE
1.) Check all bearings for noise and wear.
2.) Check all gaskets for wear and leakage.
3.) Check pump pressure; observe spray pattern
and check with gauge if necessary.
4.) Check overall performance of machine.
5.) Grease piston inside pressure regulator.
4.)
5.)
6.)
Inspect hoses for wear. Frayed or cracked
hoses should be replaced to avoid vacuum
or solution pressure loss.
Inspect power cord for wear or damage.
This cable will lay on wet carpet. To prevent
electrical shock replace cords that are
frayed or have cracked insulation
immediately.
Ensure automatic shut-off ball is working
properly.
Clean all dirt and obstructions from drain
valve and gaskets to prevent possible
leakage and premature wear.
SEMI-ANNUALLY
1.) Check vacuum motor brushes.
LUBRICATION
For hose fitting lubrication, use a light silicone
lubricant which will not damage o-rings.
7.)
8.)
STORAGE
Thoroughly clean machine if it is to be stored.
Protect this machine from freezing while in storage.
9.)
Run clean water through solution pump
when work is complete.
10.)
11.)
Empty both tanks and rinse, run vacuum (s)
for at least one minute to dry motor(s).
Store with access covers removed to allow
tanks to dry.
HEATER MODEL STORAGE
Be sure to thoroughly drain water out of heater lines
prior to storage in colder climates. This heater will
freeze and possibly crack, voiding your warranty.
PERIODIC MAINTENANCE
1.) Twice a month, flush a white vinegar solution
(One quart vinegar to two gallons of water) or
anti-browning solution (mixed as directed)
through the extractor, turning pump switch
on/off several times, flush with clean water.
This will prevent build-up of alkaline residue in
the system.
2.) Check hoses for wear, blockages, or damage.
Frayed or cracked hoses should be repaired or
replaced to eliminate vacuum or solution
pressure loss.
D-250 98828 04/08/03
6
Download from Www.Somanuals.com. All Manuals Search And Download.
MAINTENANCE
SERVICE SCHEDULE
MAINTENANCE
DAILY
WEEKLY
QUARTERLY
Check machine for cord damage
*
Check recovery dome and gasket for
damage and cleanliness
Check hoses for wear, blockages, or
damage
*
*
Check handles, switches, and knobs
for damage
Check vac motor intake filter and clean
*
*
Run one gallon of water through
system
*
*
*
*
*
*
Clean out recovery tank and check
float valve to make sure it moves freely
Clean out solution tank and remove
and clean vacuum intake screen
Clean outside of all tanks and check for
damage
Run vac motor for at least one minute
to allow motor to dry
Store with dome off tank to allow the
tank to dry
Check all gaskets for wear and leakage
*
*
Check vacuum intake screen for
damage; replace if necessary
Check pump pressure; observe spray
pattern and check with gauge if
necessary
Check and clean solution screen
Check cables for fraying
*
*
*
*
Check overall performance of machine
Check vac motor carbon brushes
*
D-250 98828 04/08/03
7
Download from Www.Somanuals.com. All Manuals Search And Download.
MAINTENANCE
ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO PERFORM
THE FOLLOWING REPAIRS.
! WARNING:
Vac Motor Carbon Brushes Replacement
VACUUM MOTOR REPLACEMENT
1. Turn off all switches and unplug machine.
2. Remove recovery tank.
End Cap
Carbon Brushes
WARNING: The green
ground wire must be
attached for safe
operation.
3. Locate the vacuum motor wires and
disconnect at the connector.
4. Remove the vacuum motor.
See wiring diagram.
5. Reverse process to install vacuum motor.
Note: When replacing carbon vac motor brushes
loosen wire terminal BEFORE removing screws on
bracket.
If armature commutator is not concentric, extremely
pitted, or grooved the motor will need to be replaced
or sent to a qualified service center to restore vac
performance.
Wire Terminal
Wire
Terminal
SOLUTION PUMP REPLACEMENT
Important:
These brushes wear quicker
as the length shortens due to
increased heat.
Spring inside brush
housing will damage motor
if brushes are
1. Turn off all switches and unplug the
machine.
Note:
Place
stop in
groove.
2. Remove recovery tank.
3. Remove solution hoses from fittings in
pump.
allowed to wear away
completely.
4. Remove the (2) screws that fasten the
pump to the frame.
5. Reverse process to install pump.
3/8
Periodically check the length of the carbon brushes.
Replace both carbon brushes when either is less
than 3/8" long.
D-250 98828 04/08/03
8
Download from Www.Somanuals.com. All Manuals Search And Download.
MAINTENANCE & TROUBLESHOOTING
D-250 PUMP MAINTENANCE
Per manufacturer’s recommendations the following maintenance should be performed
utilizing noted kits:
1.) 500 hours-Kit 55250751 replaces the V-packing, wave washer, packing spreader and
plunger guide.
2.) 500 hours-Kit 55250753 replaces the CAM bearing and insert.
3.) 1000 hours-kit 55250752 valve assembly and o-rings.
NOTE: Maintenance and repairs must be done by qualified personnel. Using non-
Windsor parts to repair this machine will void the warranty. Contact an authorized
Windsor dealer for complete details.
TROUBLE SHOOTING CHART :
PROBLEM
POSSIBLE CAUSE
SOLUTION
No power to
machine
Dead electrical circuit
Check building circuit breaker or fuse
box.
Faulty power cord
Replace.
Electrical shock
Equipment not grounding
Receptacle not grounded
Follow grounding instructions exactly.
Contact an electrician to check
building's wiring.
Internal wiring problem
Have a trained service technician check
machine's wiring.
Vac motor speed
varies or doesn't run
Worn motor brushes
Motor worn out
Replace.
Replace.
Faulty switch
Replace.
Loss of
Loose vacuum dome
Center and seal dome over tank.
Vacuum
Crack in dome or
poor joint
Replace or repair using acrylic plastic
cement only.
Lint or dirt clogging
vacuum screen
With power off clean screen.
Tighten cuffs turning counterclockwise.
Replace.
Loose cuffs on vacuum
hose
Vac motor seals leaking
Floor tool vac chamber
clogged
Wash out with hose. Pick lint out with a
wire.
Vac motor, hose, or
dome gasket
Replace.
D-250 98828 04/08/03
9
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING CONT.
Solution hose
fitting hard to
connect
Corrosion on fittings
Clean with steel wool.
Soak in acetic acid (white vinegar).
Lubricate lightly with silicone base
lubricant.
Carpet not
getting clean.
Severe soil conditions
Over saturation
Make several passes at right angles to
other. Use a prespray.
Carpet too wet
Adjust solution pressure to lower setting.
Make several passes without spray.
Carpet browning
Leaving carpet too wet
Too much chemical in
Check for loss of vac pressure.
Check label for correct solution
concentration.
.
Solution not
flowing properly
Solution hose connection
Faulty pump
Check for positive connection
Repair or replace.
Repair or replace.
Repair.
Faulty floor tool valve
Faulty pump switch
TECHNICAL SPECIFICATIONS
POWER TYPE
ELECTRICAL: 115 V, 60 Hz, 15 Amps per power cable ((D250)
230 V, 50 Hz, 15 Amps (D250IE)
ELECTRIC VACUUM MOTOR: (1) –2/1.25 HP, 2 stage, Waterlift –150” (381cm)
SOLUTION PUMP: 250 psi, adj.
SOLUTION CAPACITY: 17 gallons (64.3ltr)
RECOVERY CAPACITY: 15 gallons (56.75ltr)
GENERAL DIMENSIONS/WEIGHT
WEIGHT: 97 lbs. ( 44 kg)
LENGTH: 20” (50.80 cm)
HEIGHT: 36” (91.44 cm)
WIDTH: 16” (40.64 cm)
POWER CABLE: 2-25’ (6.35 m) (D250)
1-25' (6.35 m) (D250IE)
D-250 98828 04/08/03
10
Download from Www.Somanuals.com. All Manuals Search And Download.
115V WIRING DIAGRAM
D-250 98828 06/07/03
11
Download from Www.Somanuals.com. All Manuals Search And Download.
THIS PAGE LEFT BLANK INTENTIONALLY
D-250 98828 04/08/03
12
Download from Www.Somanuals.com. All Manuals Search And Download.
RECOVERY TANK ASSEMBLY
1
2
6
3
5
29
4
28
27
34
13
7
26
13
8
25
9
35
10
11
12
14
15
16
24
13
17
33
36
18
19
30
23
22
21
20
31
32
D-250 98828 06/07/03
13
Download from Www.Somanuals.com. All Manuals Search And Download.
RECOVERY TANK ASSEMBLY
SERIAL NO.
NOTES:
FROM
REF
PART NO.
QTY DESCRIPTION
TUBE ASM, RECOVERY TANK
1
2
3
4
5
6
7
8
05151
500009
260-64A
70546
090-12A
78475
320-05
15-808123
11-800444
390-26
35168
360-24
87013
35166
065-92
85047
70813
87016
70335
20063
39337
27508
20046
880292
75334
70015
1
1
1
6
1
1
2
1
1
3
1
1
7
1
3
1
1
3
1
1
1
1
1
1
1
2
1
2
LABEL, WARNING
ACCESS COVER CLEAR 6” W/RIM
SCR, 8 X 3/4 PFHT/S BLK ZINC
FLOAT CAGE ASSY COMPLETE SLIP
VAC STACK ASM, 17 GAL PORTABLES
VELCRO STRAPS
DUMP VALVE 2”
9
ELBOW, 1.5 2” 45D PVC SCH40
SPACER NYLON 1/4 ID X 1/2 OD
GASKET VAC MTR
PLATE, VAC
WASHER, 1/4 ID X 5/8 OD SS
GASKET, VAC MTR
VAC SPACER 2 1/4 II STAGE
VAC MTR ASM, D/B RCVRY 115V 2ST
STUD, 1/4-20 X 3.5 SS
WASHER, #10 LOCK EXT STAR SS
SCR, 10-32 X 1/2 PHTR GRN/GRND
CLAMP, 1.75” WORM GEAR X .312
HOSE, 1.5 BLK VAC X 24”
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
CUFF, VAC HOSE BLU
CLAMP, 2.25” WORM GEAR
WIRE, 4” GRN/14 76010 X 76014
TANK, RECOVERY DB DK GRY
SCR, 1/4-20 3/4 HHCS SS DL
TANK BRACE ASM, D/B
065-25
70020
SCR, 1/4-20 X 1/2 HHCS SS NP
29
30
31
32
33
34
35
36
40001R
39574
1
1
1
1
1
1
1
3
HOSEBARB, 1.5 MPT X 1.5
HOSE ASM, 1/4 HP SLTN 16.5FT
VAC HOSE 16-1/2’ W/CUFFS 1 1/2
KIT, HOSE ASM W/BAG DOM50
HOSE BAG 24” X 36”
150-44A
47356
150-65
35255
GASKET, TANK LID
35256
GASKET, DUMP VALVE
57105
NUT, 1/4-20 HEX W/ STAR WASHER
D-250 98828 06/07/03
14
Download from Www.Somanuals.com. All Manuals Search And Download.
SOLUTION TANK ASSEMBLY
6
5
31
4
7
8
3
2
63
9
67
68
12A
1
41
10
11
69
70
66
13
31
14
65
74
30
29
15
18
64
28
32
16
27
26A
17
63
61
33
25
24
19
34
62
23
60
71
22
38
21
35
8
37
20
36
38
59
8
39
38
73
72
58
40
41
54
52
53
46
43
57
42
56
31
51
76
55
50
44
8
49
38
48
45
46
47
D-250 98828 06/07/03
15
Download from Www.Somanuals.com. All Manuals Search And Download.
SOLUTION TANK ASSEMBLY
SERIAL NO.
NOTES:
FROM
REF PART NO. QTY DESCRIPTION
1
2
3
4
5
6
7
8
9
85045
39582
20046
880292
87016
70335
70813
87013
065-92
35166
360-24A
070-08
065-91
070-08A
70626
1
1
1
1
1
1
3
13
3
1
1
1
1
1
4
1
3
1
1
2
1
2
1
1
1
1
1
1
2
2
8
1
1
1
1
1
1
18
1
1
2
1
1
1
1
2
1
1
2
1
1
1
4
VAC MTR ASM, D/B SLTN 115V 2ST
HOSE, VAC EXHAUST X 9”
CLAMP, 2.25” WORMGEAR
WIRE, 4” GRN/14 76010 X 76014
WASHER, #10 LOCK EXT STAR SS
SCR, 10-32 X 1/2 PHTR GRN/GRND
STUD, 1/4-20 X 3.5 SS
WASHER, 1/4 ID X 5/8 OD SS
VAC SPACER 2 1/4 II STAGE
GASKET, VAC MTR
PLATE ASM, VAC 90 DEG
FAN 105 CFM AXIAL
PANEL ASM, CONT. 3 SW W/HEAT
FAN FINGER GUARD
SCR, #10 X 3/4 PPHST HI-LO BLK
SCR, 1/4-20 X 1 HHCS SS
SWITCH, SPST 15A EURO ROCKER
CORD 25’ BLK 14/3 SJTW/A PLUG
CORD 25’ BLK 12/3 SJTW/A PLUG
LABEL CIRCUIT INTERUPTER
HEATER MATE WARNING TAG
STRAIN RELIEF, 1/2 NPT (.48M)
TOGGLE SWITCH BOOT
10
11
12A
13
14
15
16
17
18
19
20
21
22
23
24
25
26A
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
70018
72142
060-04A
060-04
170-41
170-31
73195
330-06
330-05
3350-04
51116
22046
500345
57040
140-11
57105
87217
030-16
010-02
151-50C
70088
20008
70393
065-26
31017
56014
130-17D
31021
151-51C
31016
TOGGLE SWITCH
TOGGLE SWITCH PLATE ON/OFF
LIGHT ASM, 115V BRUSH WEAR
CLIP, NEON LAMP
LABEL, DOM3 SWITCH W/HEAT
NUT, 1/2 NPT CONDUIT
KNOB RT/TANK
NUT, 1/4-20 HEX W/STAR WASHER
WASHER, 9/16 ID MCHD
ELBOW, 1/4 NPT STREET LONG 90D
AXLE ASM, RIGHT
DB 200PSI PUMP TO QD
SCR, 10-32 X 1/2 PPHMS SS NP
CLAMP, 5/8 NYLON UL/USA
SET SCR, 1/4-20 X 1.25L
HEATER MOUNT ASM, D/B
ELBOW, 1/4 FPT X FPT UNION
NIPPLE, 1/4 CLOSE
HEATER ASM, DB COMPLETE
ELBOW, 1/4 NPT 45D STREET
DB 200PSI PUMP TO HEATER
ELBOW, 1/4 NPT STREET
CLAMP, 3/8 HOSE (D-SLOT)
HOSEBARB, 1/4NPT X 1/2H 90D DL
PUMPTEC 200PSI PUMP & MOTOR
PLUG, 1/4 BRASS PIPE
HOSE, 1/2 WIRE BOUND X 23”
PLATE, PUMP MOUNT
HOSEBARB, 3/8MPT X 1/2 90D DL
NUT, 6-32 ACORN, ZINC
20042
40047
250-79
66017
39174
065-28A
40027
57187
D-250 98828 06/07/03
16
Download from Www.Somanuals.com. All Manuals Search And Download.
SOLUTION TANK ASSEMBLY CONT'.
SERIAL NO.
FROM
REF PART NO. QTY DESCRIPTION
NOTES:
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
70232
57196
2
2
1
1
2
1
1
1
2
2
2
1
1
2
1
1
1
1
1
4
1
1
2
SCR, 10-32 X 3/8 FHMS SS
NUT, 1/2 PUSH-ON DOME CAP
WHEEL 8” BLK CENTERED HUB
AXLE ASM, LEFT
DIAMONDBACK 200 PUMP SUPPORT
CASTER SWIVEL 4” SWIVEL
SOL SCREEN (ACORN) W/RUB BASE
TANK, SOLUTION DOM 250 DK BLU
LABEL, DOMINATOR
RIVIT AL. 3/16 X 1/2 CLOSED
WASHER 1/4 X 5/8 BONDED NEOPRN
KNOB 1/4-20 X 3/4 S/S CUPPOINT
CHAIN ASM, #10 BEAD S/S W/EVES
SOLUTION COVER D/B
040-06
010-01
065-28
040-03
290-08
75349
500378
280-02
390-24
140-12
27912
260-71
56012
250-35
151-50B
250-15
41393
NIPPLE 1/4 FPT QD
D/B BPR 200PSI
HOSE, 42” GRY 3/8 1/4 MPTXCUT
HOSEBARB, 3/8 NPT X 3/8H
HINGE, ACCESS PANEL
SCR, 3-32 X 1/4 PPHMS SS
KNOB, HEX PRESS LOC WING
NUT, 1/4-20 WING SS
70127
48100
57037
70393
NOT SHOWN
SET SCR, ¼-20 X 1.25L
SUGGESTED SPARE PARTS
DESCRIPTION
PART NUMBER
FUSE 3 AMP 200 PSI
150-04A
250-33A
130-14I
130-14C
250-79E
250-79F
250-79G
140370
85047
BPR REPAIR KIT PUMPTEC
THERMOSTAT W/SPADE LEADS
THERMOSTAT RESET
PUMPTEC 300/400PSI PUMP KIT 1
PUMPTEC 300PSI PUMP KIT 2
PUMPTEC 300PSI REBUILD KIT 3
CARBON BRUSHES, VAC MOTOR
VAC MOTOR ASM, RCVRY 115V 2ST
VAC MOTOR ASM, SLTN 115V 2ST
PUMPTEC 200PSI PUMP & MOTOR
ROCKER SWITCH 2 PRONG
WHEEL 8” BLK CENTERED HUB
NUT, 1/2 PUSH-ON DOME CAP
CASTER SWIVEL 4” SWIVEL
KNOB RT/TANK
85045
250-79
330-02
040-06
57196
040-03
140-11
260-64A
290-08
370-08
51116
ACCESS COVER CLEAR 6” W/RIM
SOL SCREEN (ACORN) W/RUB BASE
DUMP VALVE SEAL 1-1/2”
LIGHT ASM, 115V BRUSH
TOGGLE SWITCH
HOSE, PRIMING KIT FEMALE QC
330-05
39572
D-250 98828 06/07/03
17
Download from Www.Somanuals.com. All Manuals Search And Download.
WINDSOR INDUSTRIES
New Machine Warranty
Limited Warranty
Windsor Industries, Inc. warrants new machines against defects in material and workmanship under normal use and service to the
original purchaser. Any statutory implied warranties, including any warranty of merchantability or fitness for a particular purpose, are
expressly limited to the duration of this written warranty. Windsor will not be liable for any other damages, including but not limited
to indirect or special consequential damages arising out of or in connection with the furnishing, performance, use or inability to use
the machine. This remedy shall be the exclusive remedy of the buyer. The warranty period is subject to the conditions stated below.
6 / 3 / 1 Warranty: 6 Years Polyethylene (PE) Housings, 3 Years Parts, and 1 Year Service Labor
Subject to conditions outlined below, Windsor Industries warrants rotationally molded PE housings and parts on all of its machines to
be free from defects in material and workmanship, under normal use and service for six (6) years to the original owner.
Under this warranty we guarantee the performance of non-polyethylene parts and components to be free from defects and for up to
three (3) years to the original end user. Parts replaced or repaired under this warranty are guaranteed for the remainder of the original
warranty period. (See table below)
Service labor charges are covered for up to one (1) year from the date of purchase through authorized Windsor service provider. No
travel coverage is extended for cord-electric models. See table below for each general product model warranty coverage.
Product
PE Housing & Parts
Non- PE Parts
Service Labor
Travel
Rider Scrubbers
Rider Sweepers
6 years
6 years
6 years
6 years
6 years
6 years
6 years
6 years
1 year
-
3 years
1 year
3 years
1 year
3 years
3 years
3 years
1 year
1 year
2 year
2 year
1 years
1 years
1 years
1 years
1 years
1 years
1 years
1 year
6 Months
6 Months
6 Months
6 Months
Walk Behind Scrubbers
Walk Behind Sweepers
Extractors
Polishers / Elec. Burnishers / GH
Wide Areas Vacuums
-
-
-
-
-
-
VacPak Vacuums
1 year
1 year
6 months
Air Movers / Dri-matic / TITANꢀ
Propane Burnishers / Strippers
Tracer/Flex Sweepers/Scrubbers
6 years
90 days
Brush motor, Vacuum motor, Belts – 3 years
Vacuum motor, Belts – 2 years
All other parts – 1 year
All other parts – 1 year
VERSAMATICꢁ
SENSORꢁ
Product exceptions and Exclusions:
S
Extractor brush motors, pump motors, ALL PC boards and electronics, ALL Vacuum motors (other than VERSAMATICꢁ and
SENSORꢁ), ALL pumps, and FLEXSOLꢀ diaphragms carry a one (1) year parts and service labor warranty.
The Onanꢁ engines have three (3) year manufacturer’s warranty. The Hondaꢁ and Kawasakiꢁ engines have two (2) year
manufacturer’s warranty. NOTE: The engine warranty is administered through the engine manufacturer and must be repaired at
an authorized service center.
S
Normal wear items and accessories including, but not limited to, belts, brushes, capacitors, carbon brushes, casters, clutches, cords,
filters, finishes, gaskets, hoses, light bulbs, rectifiers, switches, squeegees, bearings, pulleys, relays, actuating cables, wheels, tires,
propane tanks, and batteries will be warranted for manufacturing defects for 90-days from the purchase date.
The warranty commences on the purchase date by the original end user from an authorized Windsor agent, subject to proof of
purchase. The Machine Registration Card must be completed and returned immediately at the time of purchase. If proof of purchase
cannot be identified, the warranty start date is 90 days after the date of sale to an authorized Windsor distributor. Parts replaced or
repaired under warranty are guaranteed for the remainder of the original warranty period.
Windsor Industries reserves the right to change its warranty policy without notice – Rev2 10/16/02
1
Windsor Industries, Inc. ● a Castle Rock Industries company ● 1351 W. Stanford Ave. ● (303) 762-1800 ● 800-444-7654 ● FAX (303) 865-2800
Download from Www.Somanuals.com. All Manuals Search And Download.
WINDSOR INDUSTRIES
New Machine Warranty
90 Day Warranty Extension Available
Upon receipt of the Machine Registration Card, Windsor will extend by 90 days, from the date of purchase, all items included under
the one-year provision. This applies only to one-year items and does not include 90-day wear items.
This Warranty Shall Not Apply To:
1. Any product that has been subject to abuse, misuse, neglect or unauthorized alteration (including the use of incompatible or
corrosive chemicals or overloading of capacity).
2. Products that have experienced shipping or freight damage.
3. Repairs necessary to correct any failure due to improper pre-delivery service and inspection by the selling dealer.
4. Excessive time for cleaning units in preparation for repair.
5. Any repairs resulting from poor initial service work or improper diagnosis.
6. Tune-up parts such as plugs, plug wires and condensers.
7. Any design alterations performed by an organization not authorized or specified by Windsor.
8. Battery and charger warranties are handled directly with the manufacturer (Trojanꢁ batteries and Lesterꢁ chargers).
9. High-pressure washing.
10. Electrical components exposed to moisture.
If difficulty develops during the warranty period, contact the authorized Windsor agent from whom the product was purchased.
Windsor Industries, Inc. may elect to require the return of components to validate a claim. Any defective part to be returned must be
shipped freight prepaid to an authorized Windsor Distributor/Service Center or to the Windsor factory.
Use Of Parts Not Approved By Windsor Industries, Inc. Will Void All Warranties
This warranty is valid only for all products sold after July 1, 1995. A product sold before that date shall be covered by the limited
warranty in effect at the date of sale to the original purchaser.
Windsor Industries reserves the right to change its warranty policy without notice – Rev2 10/16/02