INSTALLATION INSTRUCTIONS  
HOOD MODELS WPN  
By CNP INDUSTRIES, INC.  
P.O. Box 18645 Anaheim, Ca 92817 (877) 387-6721  
PLEASE READ ENTIRE INSTRUCTION BEFORE PROCEEDING.  
INSTALLATION MUST COMPLY WITH ALL LOCAL CODES.  
IMPORTANT: Save these Instructions for the Local Electrical Inspector's use.  
INSTALLER: Please leave these Installation Instructions with this unit for owner.  
OWNER: Please retain these Instructions for future reference  
IMPROTANT SAFETY INSTRUCTIONS  
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS,  
HOODS SHOULD BE INSTALLED WITH VENTILATORS APPROVED FOR USE WITH THE HOOD.  
SEE TABLE 1 OF THIS INSTRUCTION FOR APPROVED VENTILATORS.  
C. When cutting or drilling into wall or  
ceiling, do not damage electrical wiring  
and other hidden utilities.  
WARNING - TO REDUCE THE  
RISK OF FIRE, ELECTRIC  
SHOCK, OR INJURY TO  
PERSONS, OBSERVE THE  
FOLLOWING:  
A. Installation work and Electrical  
Wiring Must be Be Done By Qualified  
Person(s) In Accordance With All  
Applicable Codes & Standards,  
Including Fire-Rated Construction.  
“WARNING” To Reduce The Risk Of  
Fire, Use Only Metal Duct Work.  
B. Sufficient air is needed for proper  
combustion and exhausting of gases  
through the flue (chimney) of fuel  
burning equipment to prevent  
backdrafting. Follow the heating  
equipment manufactures guideline and  
safety standard such as those published  
by the National Fire Protection  
Association (NFPA) and the American  
Society for Heating, Refrigeration and  
Air Conditioning Engineers (ASHRAE),  
and the local code authorities.  
D. Before Servicing or Cleaning Unit,  
Switch Power off At Service Panel And  
Lock Service Disconnecting Means to  
Prevent Power From Being Switched On  
Accidentally. When The Service  
Disconnecting Means Cannot be Locked,  
Securely Fasten A Prominent Warning  
Device, Such As A Tag, To The Service  
Panel  
CAUTION - TO REDUCE THE RISK OF FIRE AND TO PROPERLY EXHAUST AIR, BE SURE TO  
DUCT AIR OUTSIDE FOR DUCTED FANS DO NOT VENT EXHAUST AIR INTO SPACE WITHIN  
WALLS OR CEILING OR INTO ATTICS, CRAWL SPACES OR GARAGES.  
Read this instruction completely before starting installation. Planning the complete installation before starting any work is  
highly recommended. This includes all aspects of the installation including hood location, ducting, electrical requirements,  
and adequacy of mounting surfaces.  
This hood has been designed to be used with the ventilators shown in Table-1.  
Before cutting into cabinets, it is necessary to confirm that the correct ventilator  
is being used. Your dealer should have reviewed your needs prior to your  
purchase. Be sure you have the correct ventilation system. CAUTION: To  
Reduce The Risk Of Fire And Electrical Shock, Install This RangeHood Only  
With Blowers Manufactured By Wind Crest.  
TABLE - 1  
Use model VEN030I or VEN060I  
for internal ventilator. Use  
VEN060E, VEN120E, VEN100E  
or VEN150E for remote ventilator  
DUCTING: Use a minimum 8" round duct for VEN030I, VEN060I and VEN060E installations. Use a minimum 10" round  
duct for VEN120E, VEN100E, VEN150E and VEN060I-Dual installations. Use #10100 8" - round transition or #10287 10"-  
round transition from hood to ducting. Other Transition are available See your Dealer for details.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DUCT COVER INSTALLATION INSTRUCTION FOR WPN MODELS  
PLEASE READ DUCT COVER AND HOOD INSTRUCTION  
COMPLETELY BEFORE PROCEEDING WITH INSTALLATION  
PARTS: One 15” Duct Cover Section  
One 19” Duct Cover Section  
One Duct Cover Bracket  
Two #8 x 1-1/2” Screws (Mount duct cover bracket to ceiling)  
Four #8 x 3-1/2” Screws Secure duct cover section 1 and 2)  
Four #8 x 1/2“ Screw Mount duct cover to hood)  
Your WPN model hood includes a duct cover, which can be used as an alternate installation method to enclose the  
ventilation duct. The hood can also be mounted under a cabinet.  
HOOD UNDER CABINET  
INSTALLATION  
HOOD WITH DUCT COVER  
INSTALLATION  
Two typical installation options shown above  
When used, the duct cover is designed to accommodate typical ceiling heights of 8-ft to 10-ft.  
CEILING  
CEILING  
CEILING  
19" MIN  
32" MAX  
19"  
15"  
15"  
USING DUCT COVER  
SECTION - 1 ONLY  
USING DUCT COVER  
SECTION - 2 ONLY  
USING DUCT COVER  
SECTION - 1 & 2 ONLY  
CAUTION: To prevent damaging the duct cover, DO NOT remove the protective covering until you are  
ready to assemble the cover to the hood.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1) Decide on hood location, position above cooking surface and type of air discharge to be used (See Hood  
Installation Instruction). When using the Duct Cover(s) plan on spacing from the top of the hood to the  
ceiling 1/8” larger than the duct cover length being used. This allows assembly of the duct cover after  
installation of the hood, electric connections and ducting. The small gap, at top of duct, remaining after  
installation will not be noticeable in most applications. If necessary a small quarter-round can be used to  
this gap at the ceiling interface.  
SPACING TO  
BE 1/8"  
LARGER THAN  
DUCT COVER  
BEING USED  
2) When using the duct cover and hood, locate hood centerline on wall and mount the Duct Cover Bracket to  
ceiling centered on the hood centerline, use #8 x 1-1/2” screws to mount bracket. Mount the bracket to the  
ceiling with edge “A” against the hood-mounting wall. Wood framing should be located, behind wallboard,  
in the area of the ceiling. If not, use anchors to fasten bracket to ceiling.  
SECURE  
TO  
CEILING  
A
CEILING  
DUCT COVER  
BRACKET  
SECURE W/2  
#8 SCREWS  
C
L HOOD  
WALL  
The Duct Cover Bracket is used to ensure the Duct Cover is retained against the wall, for appearance purposes,  
when the longer length of cover is used.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3) Mount the hood and install wiring and ducting per Hood Installation Instruction.  
4) When using Duct Cover sections 1 & 2, set in length of duct needed and secure sections together using four #8 x 3/8”  
screws. Flanges on Duct Cover Section should be positioned facing toward same end of Duct Cover assembly. HINT:  
Predrive screws into holes, remove screws, remove protective cover from Duct Cover Sections, assemble Duct Cover  
sections and set length (Use extreme caution to avoid scratching Duct Cover Sections), reinstall screws and  
tighten. This will ease assembly of screws and prevent scratching of Duct Cover.  
REMINDER: Length of Duct Covers should be 1/8” smaller than spacing of hood top to ceiling.  
15" SECTION  
SCREW, BOTH  
15" SECTION  
FLANGE  
SIDES WITH  
DESIRED  
DUCT COVER  
HEIGHT  
#8 X 3/8 SCREWS  
19" SECTION  
19" SECTION  
FLANGE  
5) Predrive #8x1/2” screws into bottom flange of duct cover. Remove screws and aside for use when mounting duct  
cover to hood.  
6) Install the duct cover onto the hood, flanges facing down, and spread the sides of the Duct Cover slightly and position  
the cover over the Duct Cover Bracket.  
7) Fasten Duct Cover to hood using screws from step-5. This should be done before installing internal blower unit.  
8) Install internal blower unit or remote blower unit as required.  
RECEPTACLE BOX COVER  
COVER IS PACKED WITH FILTERS  
HO OD TOP  
KNOCK O UTS  
H OO D W IRING  
ACCE SS  
COVER  
M OUNTING  
SCREW  
REMOVE APPROPRIATE KNOCK OUTS AND CONNECT WIRING  
ACCORDING TO HOOD AND BLOWER INSTALLATION INSTRUCTIONS.  
CAUTION: ALWAYS INSTALL RECEPTACLE BOX COVER.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RECEPTACLE  
PLUG  
POWER SUPPLY  
L1  
N
G
RECEPTACLE  
BOX  
BLOWER  
MOTOR  
18 B # 12  
18 G # 11  
18 W # 25  
18 W  
1
2
3
4
1
2
3
4
18 B  
18 R  
18 B # 24  
18 BL #23  
18 R # 22  
18 BL  
18 W # 13  
18 BL # 3  
18 B # 2  
18 W # 10  
18 R # 4  
18 B # 7  
18 W # 9  
LEFT  
RIGHT  
LIGHT  
LIGHT  
1
3-SPD  
A
1
2
5
3
LIGHT  
SWITCH  
ROTARY  
SWITCH  
18 B # 6  
2
3
4
6
B
18 B # 8  
18 W # 5  
WIRING DIAGRAM-INTERNAL BLOWER & LIGHTING  
RECEPTACLE  
POWER SUPPLY  
L1  
PLUG  
N
G
RECEPTACLE  
BLOWER  
MOTOR  
BOX  
18 B # 12  
18 G # 11  
18 W # 25  
18 W  
1
2
3
4
1
2
3
4
18 B  
18 R  
18 B # 24  
18 BL #23  
18 R # 22  
18 BL  
18 W # 13  
RIGHT  
HEAT  
LIGHT  
LEFT  
HEAT  
LIGHT  
18 B # 19  
18 B # 17  
18 W # 20  
18 B # 18  
18 W # 26  
18 B # 16  
18 W # 21  
18 BL # 3  
18 B # 2  
18 W # 10  
18 R # 4  
18 B # 7  
RIGHT  
LIGHT  
18 W # 9  
LEFT  
LIGHT  
1
HEAT  
LIGHT  
SWITCH  
RIGHT  
3-SPD  
ROTARY  
SWITCH  
HEAT  
A
1
2
1
2
1
2
5
3
6
LIGHT  
SWITCH  
LIGHT  
SWITCH  
LEFT  
18 B # 6  
2
3
4
B
18 W # 5  
18 B # 14  
18 B # 15  
18 B # 8  
WIRING DIAGRAM-INTERNAL BLOWER, LIGHTING & HEAT LAMPS  
Rev B  
Download from Www.Somanuals.com. All Manuals Search And Download.  

West Bend Fondue Maker 88999 User Manual
Westinghouse Fan WJ WH05 User Manual
Whirlpool Air Conditioner ACC602 User Manual
WiebeTech Laptop Docking Station NBDDV4 User Manual
Yamaha Guitar 11391 User Manual
Zanussi Freezer ZUF 2320 User Manual
Zanussi Oven ZPB 1260 User Manual
Zanussi Refrigerator ZX 57 3 W User Manual
Zanussi Washer ZWF 1230 W User Manual
Zenoah Trimmer EXZ2401S User Manual