Wind Crest Ventilation Hood WCL User Manual

INSTALLATION INSTRUCTIONS  
HOOD MODELS WSL, WCL, & WER  
By CNP INDUSTRIES, INC.  
P.O. Box 18645 Anaheim, Ca 92817 (877) 387-6721  
PLEASE READ ENTIRE INSTRUCTION BEFORE PROCEEDING.  
INSTALLATIONS MUST COMPLY WITH ALL LOCAL CODES.  
IMPORTANT: Save these Instructions for the Local Electrical Inspector's use.  
INSTALLER: Please leave these Installation Instructions with this unit for owner.  
OWNER: Please retain these Instructions for future reference  
IMPROTANT SAFETY INSTRUCTIONS  
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS,  
HOODS SHOULD BR INSTALLED WITH VENTILATORS APPROVED FOR USE WITH THE HOOD.  
SEE TABLE 1 OF THIS INSTRUCTION FOR APPROVED VENTILATORS.  
C. When cutting or drilling into wall or  
ceiling, do not damage electrical wiring  
and other hidden utilities.  
B. Sufficient air is needed for proper  
combustion and exhausting of gases  
through the flue (chimney) of fuel  
burning equipment to prevent  
backdrafting. Follow the heating  
equipment manufactures guideline and  
safety standard such as those published  
by the National Fire Protection  
Association (NFPA) and the American  
Society for Heating, Refrigeration and  
Air Conditioning Engineers (ASHRAE),  
and the local code authorities.  
WARNING - TO REDUCE THE  
RISK OF FIRE, ELECTRIC  
SHOCK, OR INJURY TO  
PERSONS, OBSERVE THE  
FOLLOWING:  
A. Installation work and Electrical  
Wiring Must be Be Done By Qualified  
Person(s) In Accordance With All  
Applicable Codes & Standards.  
Including Fire-Rated Construction.  
“WARNING” To Reduce The Risk Of  
Fire, Use Only Metal Duct Work.  
D. Before Servicing or Cleaning Unit,  
Switch Power off At Service Panel And  
Lock Service Disconnecting Means to  
Prevent Power From Being Switched On  
Accidentally. When The Service  
Disconnecting Means Cannot be Locked,  
securely Fasten A Prominent Warning  
Device, Such As A Tag, To The Service  
Panel  
CAUTION - TO REDUCE THE RISK OF FIRE AND TO PROPERLY EXHAUST AIR, BE SURE TO  
DUCT AIR OUTSIDE FOR DUCTED FANS DO NOT VENT EXHAUST AIR INTO SPACE WITHIN  
WALLS OR CEILING OR INTO ATTICS, CRAWL SPACES OR GARAGES.  
Read this instruction completely before starting installation. Planning the complete installation before starting any work is  
highly recommended. This includes all aspects of the installation including hood location, ducting, electrical requirements,  
and adequacy of mounting surfaces.  
This hood has been designed to be used with the ventilators shown in Table-1.  
Before cutting into cabinets, it is necessary to confirm that the correct ventilator  
is being used. Your dealer should have reviewed your needs prior to your  
purchase. Be sure you have the correct ventilation system.  
TABLE - 1  
Use model VEN030I or VEN060I  
for internal ventilator. Use  
VEN060E, VEN120E, VEN100E  
or VEN140E for remote ventilator  
CAUTION: To Reduce The Risk Of Fire And Electrical Shock, Install This  
Rangehood Only With Blowers Manufactured By Wind Crest.  
DUCTING: Use a minimum 8" round duct for VEN030I, VEN060I and VEN060E installations. Use a minimum 10" round  
duct for VEN120E, VEN100E, VEN140E and VEN060I-Dual installations. Use #10100 8" - round transition or #10287 10"-  
round transition from hood to ducting. Other Transition options are available See your Dealer for details.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RECEPTACLE  
PLUG  
POWER SUPPLY  
L1  
N
G
RECEPTACLE  
BOX  
BLOWER  
MOTOR  
18 B # 12  
18 G # 11  
18 W # 25  
18 W  
1
2
3
4
1
2
3
4
18 B  
18 R  
18 B # 24  
18 BL #23  
18 R # 22  
18 BL  
18 W # 13  
18 BL # 3  
18 B # 2  
18 W # 10  
18 R # 4  
18 B # 7  
18 W # 9  
LEFT  
RIGHT  
LIGHT  
LIGHT  
1
3-SPD  
A
1
2
5
3
LIGHT  
SWITCH  
ROTARY  
SWITCH  
18 B # 6  
2
3
4
6
B
18 B # 8  
18 W # 5  
WIRING DIAGRAM-INTERNAL BLOWER & LIGHTING  
RECEPTACLE  
POWER SUPPLY  
L1  
PLUG  
N
G
RECEPTACLE  
BLOWER  
MOTOR  
BOX  
18 B # 12  
18 G # 11  
18 W # 25  
18 W  
1
2
3
4
1
2
3
4
18 B  
18 R  
18 B # 24  
18 BL #23  
18 R # 22  
18 BL  
18 W # 13  
RIGHT  
HEAT  
LIGHT  
LEFT  
HEAT  
LIGHT  
18 B # 19  
18 B # 17  
18 W # 20  
18 B # 18  
18 W # 26  
18 B # 16  
18 W # 21  
18 BL # 3  
18 B # 2  
18 W # 10  
18 R # 4  
18 B # 7  
RIGHT  
LIGHT  
18 W # 9  
LEFT  
LIGHT  
1
HEAT  
LIGHT  
SWITCH  
RIGHT  
3-SPD  
ROTARY  
SWITCH  
HEAT  
A
1
2
1
2
1
2
5
3
6
LIGHT  
SWITCH  
LIGHT  
SWITCH  
LEFT  
18 B # 6  
2
3
4
B
18 W # 5  
18 B # 14  
18 B # 15  
18 B # 8  
WIRING DIAGRAM-INTERNAL BLOWER, LIGHTING & HEAT LAMPS  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dual Internal Ventilators  
NOTE: Wiring harness #10220 is required to complete the installation  
of dual VEN060I ventilators and must be ordered separately.  
Cabinet Mounting  
When using two (2) VEN060I ventilators the cabinet mounting must accommodate two discharge transitions. Wiring  
and discharge holes are shown in FIG 6.  
HINT: Transition dimensions may very. Before assembling transitions to hood, fit them into the prepared cabinet  
opening to be sure the openings are large enough to accommodate the transition. Enlarge the hole if required  
Hood Preparation  
The hood must be prepared for dual ventilator mountings by removing the discharge coverplate and two “breakaway”  
discharge hole plates. To remove, break the metal webs holding the plate and remove completely. See FIG 5. Break the  
metal webs by placing a screwdriver at one corner of the plate and hitting screwdriver sharply with a hammer. After breaking  
a second web the plate can be flexed to break other webs.  
Wear eye protection when using tools.  
Attach the transition (See DUCTING, pg 1), obtained separately from your local hardware or available through your dealer,  
and install the hood as described previously in this instruction.  
Ventilator Installation  
Install the ventilators as previously described, see FIG 1 and instruction on same page of this document. Connect the  
ventilators to the receptacle in the hood junction box using Harness #10220, ordered separately. Dress the wires and  
secure to bracket “A” see FIG – 5, using the wire tie supplied with the harness. Follow the remaining instructions for  
operating checks to complete the installation.  
FIG - 5  
AIR DISCHARGE  
KNOCKOUTS  
AIR DISCHARGE  
KNOCKOUTS  
HOOD TOP  
TIE  
HOOD BACK  
"A"  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Weed Eater Trimmer 530163448 User Manual
Weil McLain Boiler WGO User Manual
Westinghouse Indoor Furnishings 70287 User Manual
Whirlpool Refrigerator 2184591 User Manual
Wolf Cooktop ICBCT15E User Manual
Xerox Scanner XDM5155DWU User Manual
Yamaha Boat 212SS User Manual
Yamaha Electronic Keyboard EZ J200 User Manual
Yamaha MP3 Docking Station MCR B142BL Black User Manual
Zanussi Refrigerator ZRT 1675 User Manual