WHITE-RODGERS WALL THERMOSTATS
HEATING/COOLING AND COOLING ONLY ASTRO* STATS WITH
SELECTOR-SWITCHES
•
DUSTPROOF SEALED MERCURY CELLS OR SNAP-ACTION CONTACTS WITH
DUSTCOVER
•
•
•
•
•
BEIGE CASE WITH GOLD TONE DIAL
POSITIVE CONTACT SNAP-SWITCHES ON SUBBASE
BIMETAL THERMOMETER
CLEAR FACEPLATE - REMOVABLE FOR EASY CLEANING
HEATING AND COOLING ANTICIPATORS PROVIDE NARROW DIFFERENTIAL
CONTROL OF ROOM TEMPERATURE
Part No.: 1D56-310
1F56-301
1F56-444
1E56-444
P574
P574
P574
P577
1D56-301 SHOWN
1F56-444 SHOWN
1E56-444 SHOWN
ASTROSTATS WITH SNAP ACTION SWITCH
•
•
•
•
SNAP ACTION CONTACTS WITH DUST COVER
NON-SUSCEPTIBLE TO SLIGHT JARS AND VIBRATIONS
IDEAL FOR MOBILE HOME USE
HEATING AND/OR COOLING ANTICIPATORS PROVIDE A NARROW DIFFERENTIAL CONTROL
OF ROOM TEMPERATURE
Part No.: 1D30-316
1C30-302
P578
1D30-316 SHOWN
HEAT PUMP THERMOSTAT
•
•
MANUAL CHANGEOVER
DUAL MERCURY CELL ARRANGEMENT ON A SINGLE BI-METAL PROVIDES CONTROL
WITHOUT COMPLICATED GEAR AND LEVER ARRANGEMENTS
•
•
THERMOSTAT MOUNTS TO SUBBASE WITH POSITIVE CAPTIVE SCREWS
SUBBASE TERMINAL SCREWS SPACED AND IDENTIFIED FOR EASY INSTALLATION
Part No.: 1F58-058
P583
202
Download from Www.Somanuals.com. All Manuals Search And Download.
WHITE-RODGERS WALL THERMOSTATS
COMFORT-SET 80 SERIES SINGLE STAGE DIGITAL THERMOSTATS (cont)
STANDARD FEATURES:
•
•
•
•
Choice of 5/1/1 day or 7 day programmable or non-programmable
4 time and 4 temperature settings per program (heat & cool)
Energy savings up to 33%
Patented pre-programmed software simplifies time and temperature
programming
•
•
•
Indefinite setpoint Hold or programmable timed Hold up to 8 hours
Temporary temperature override until next program period
Dual-Powered…choice of battery-powered or hardwired, for all single
stage applications
•
•
•
Selectable Energy Management recovery
Meets ENERGY STAR® specifications
Meets California Building Code, Title 24
Single Stage
2 Programs
Part No.: 1F80-261
COMFORT-SET 90 SERIES SINGLE STAGE DIGITAL THERMOSTATS
STANDARD FEATURES:
Single Stage
3 Programs
•
Choice of 7 or 5/1/1 day or 7 day programmable or
non-programmable
Part No.: 1F90-371
•
•
•
4 time and 4 temperature settings per program (heat & cool)
Energy savings up to 33%
Patented pre-programmed software simplifies time and
temperature programming
Single Stage
7 Programs
•
•
•
•
•
•
Large Comfort-View™ luminescent display
Permanent program retention
Vacation programming
Part No.: 1F97-371
Air filter change indicator
Daylight Savings Time quick-change button
Temporary temperature override from 15 minutes to 19 hours or
indefinite setpoint hold
•
•
•
•
•
•
•
•
•
•
•
Display temperature recalibration (+/-5º)
Maintains room temperature differential within .8 degree
Automatic Heat/Cool System Changeover
Selectable Energy Management Recovery
Built-in system and thermostat diagnostics
Digital-signal remote sensors (optional)
Meets ENERGY STAR® specifications
Meets California Building Code, Title 24
Compressor lockout protection
Millivolt compatible
Electric heat option
P4556
204
Download from Www.Somanuals.com. All Manuals Search And Download.
WHITE-RODGERS WALL THERMOSTATS
COMFORT-SET 90 SERIES MULTI STAGE & HEAT PUMP
DIGITAL THERMOSTATS
STANDARD FEATURES:
Heat Pump
•
•
Heat pump warm air start
Energy Source Optimizer selects heat pump or fossil fuel
•
•
7-day programming
Four pre-programmed time/temperature periods per
day
Part No.: 1F94-371
•
•
•
•
Vacation Programming button
Programmable fan continuous in any period
Programmable fan on/off delays
Separate set-up menus: Installer menu, User menu,
Keypad lockout (total/partial) menu
Large Comfort-View™ display and lighted keypad
Permanent program retention – no batteries required
Daylight Savings Time quick-change button
Air filter change indicator
Multi Stage
Part No.: 1F95-371
•
•
•
•
•
•
•
•
Ignition control reset
Remote sensing (optional)
Outdoor temperature sensing (optional)
Multi-stage,heat pump, or single stage up to 3-stage
heat/2-stage cool
•
•
•
•
•
•
•
Auto-changeover
EMR (Energy Management Recovery)
Meets ENERGY STAR® specifications
Meets California Building Code, Title 24
Compressor lockout/Auxiliary run time
Adjustable differential
Telephone access run program (X10 module
required)
205
Download from Www.Somanuals.com. All Manuals Search And Download.
TOTALINE THERMOSTAT GUARDS
THERMOSTAT GUARDS
•
•
•
•
•
•
Metal: beige
Plastic: beige or clear
Sizes fit most thermostats
Solid and ring bases
Have key lock
P593
Metal
Virtually tamper proof
P594
Plastic
Metal
WIDTH (in.)
3-7/8
5-1/4
5-1/4
6-3/8
6-3/8
6
HEIGHT (in.)
3-1/2
DEPTH (in.)
BASE
Solid
Solid
Ring
Solid
Ring
Ring
Solid
Solid
Ring
STYLE
Beige
Beige
Beige
Beige
Beige
Beige
Beige
Beige
Beige
PART NO.
2-1/2
3
3-1/4
3
3-1/4
3-1/8
3
3-1/2
3-9/16
P269-0010
P269-0011
P269-0012
P269-0013
P269-0014
P269-0015
P269-0016
P269-0017
P269-0018
4-5/8
4-5/8
3-1/2
3-1/2
3-3/16
4-3/4
5-3/8
6-1/4
7-1/4
6-3/4
4-1/4
Plastic
WIDTH (in.)
HEIGTH (in.)
3-1/2
DEPTH (in.)
2-1/2
2-1/2
3
BASE
Solid---
Solid
Solid
Ring
Solid
Ring
Solid
Ring
STYLE
Clear-
Beige
Clear
Clear
Beige
Beige
Clear
Clear
Beige
Beige
Clear
Beige
PART NO.
P269-0001
P269-0002
3-7/8
3-7/8
5-1/4
5-1/4
5-1/4
5-1/4
6-3/8
6-3/8
6-3/8
6-3/8
8-1/4
8-1/4
3-1/2
4-5/8
4-5/8
4-5/8
4-5/8
3-1/2
3-1/2
3-1/2
P269-0003
P269-0004
P269-0005
P269-0006
3-1/4
3
3-1/4
3
3-1/4
3
3-1/4
3-1/2
3-1/2
Solid
Ring
Ring
3-1/2
5-3/8
5-3/8
P269-0007
P269-0008
Ring
206
Download from Www.Somanuals.com. All Manuals Search And Download.
MISCELLANEOUS PARTS
MISCELLANEOUS PARTS
ROOM AIR CONDITIONER SERVICE CORDS
•
1/4 IN. QUICK CON-
NECT TERMINALS ON
POWER LEADS
•
•
RING TERMINAL ON
GROUND WIRE
IVORY COLOR EXCEPT
51PC CORDS ARE
GRAY
P402
FIG. A
FIG. B
FIG. C
FIG. D
FIG. E
FIG. F
FIG. G
WIRE
GAUGE
14
LENGTH
(in.)
WIRE
GAGE
14
LENGTH
PART NO.
(in.)
FIGURE
AMPS VOLTS
PART NO.
FIGURE
AMPS VOLTS
A
B
15
15
125
250
93
51SA400353
52SQ402334
51CM400964
60AA400094
82
66
82
52CQ400994
51CM400974
52CQ401004
E
20
30
250
250
14
14
12
66
60
113
12
12
G
20
125
D
ROOM AIR CONDITIONER FILTER
The 51YA680001 polyure-
thane foam replacement
room air conditioner filter
measures 22-3/4 in. x
14-1/2 in. x 1/4 in. thick. It
can be trimmed to fit most
RAC’s in use today.
Part No.:
51YA680001S
P729
207
Download from Www.Somanuals.com. All Manuals Search And Download.
TEMPERATURE ACTUATED SWITCHES
CONTROL BULB
•
•
CONTROL BULB WELLS FOR USE WITH
TEMPERATURE CONTROLLERS
BUSHING INCLUDED
C
D
B
A
DIMENSIONS (in.)
FOR BULB
THREAD
PART NO.
DIA. (in.)
5/16
3/8
SIZE NPT
1/2-14
1/2-14
1/2-14
1/2-14
3/4-14
1/2-14
A
13.0
6.3
7.6
8.7
8.7
5.7
B
C
D
.4
.4
.4
.7
.7
.7
11.5
5.0
5.8
4.2
4.2
4.2
1.2
.7
1.4
3.7
3.7
.7
HL79PZ001
30HH406102
HL79ZZ002
HL79MZ001
HL79MZ005
HL79MZ007
3/8
1/2
1/2
1/2
AQUASTAT CONTROLLERS
Part No. P672-L6006C
Part No. P672-L4006
•
OPERATE IN RESPONSE TO
TEMPERATURE CHANGES IN
HYDRONIC HEATING SYSTEMS.
PROVIDES SPDT SWITCHING FOR
THREE-WIRE APPLICATIONS.
COMBINES CIRCULATOR CONTROL
WITH HIGH AND LOW LIMITS.
HORIZONTAL OR VERTICAL SURFACE
•
TOTALLY ENCLOSED MICRO
SWITCH SNAP-ACTING SWITCHES
OPERATE ON TEMPERATURE RISE
TO SET POINT.
VISIBLE CONTROL POINT SCALE
AND EXTERNAL ADJUSTMENT
SCREW PERMIT EASY SETTING.
HORIZONTAL OR VERTICAL
INSERTION AND DIRECT OR WELL
IMMERSION OF SENSING ELEMENT.
•
•
•
•
•
•
MOUNTING.
VISIBLE CONTROL POINT SCALE AND
EXTERNAL ADJUSTMENT SCREW
PERMIT EASY SETTING.
P4320
Part No. P672-L7124U UNIVERSAL OIL ELECTRONIC AQUASTAT CONTROLLER
•
PROVIDES ELECTRONIC TEMPERATURE SENSING IN A UL LIMIT-RATED CONTROL WITH A
SINGLE SENSING PROBE.
•
•
•
CONTROLS CIRCULATOR, OIL BURNER, AND BOILER TEMPERATURE.
REPLACES THE L8124A, L8124C, L8148A CONTROLLERS.
THE L7124U HAS A CASE THAT CAN BE CONVERTED FOR EITHER HORIZONTAL OR
VERTICAL MOUNTING.
HONEYWELL
PART NO.
PART NO.
P672-L4006A
P672-L4006B
P672-L6006C
P672-L7124U
L4006A1009
L4006B1007
L6006C1018
L7124U1003
P4321
208
Download from Www.Somanuals.com. All Manuals Search And Download.
TEMPERATURE ACTUATED SWITCHES
SWITCHING RELAYS
Part No. P673-RA889A SWITCHING RELAY
(HYDRONIC)
Part No. P673-R8845A UNIVERSAL
SWITCHING RELAY (HYDRONIC)
•
•
•
•
HIGH LOAD SWITCHING RELAY.
TROUBLESHOOTING LED.
REPLACEABLE TRANSFORMER FUSE.
LONG LIFE DC RELAY DRIVE CONTROL
TECHNOLOGY.
RELAY FOR USE WITH EXTERNAL 24 VAC
OR 24 VDC SUPPLY, WITH LINE-VOLTAGE
CONTROL, OR WITH INTERNAL 24-V
TRANSFORMER SUPPLY.
•
•
•
•
•
REPLACEABLE, SOCKETED RELAY.
TWO TROUBLESHOOTING LED’S.
PUSH-TO-TEST BUTTON.
REPLACEABLE TRANSFORMER FUSE.
LOW VOLTAGE CONTACTS FOR POWERPILE
APPLICATIONS.
RELAYS CAN BE USED WITH EXTERNAL
24-VAC OR 24-VDC SUPPLY, LINE-VOLTAGE
CONTROL, OR WITH INTERNAL 24-V
TRANSFORMER.
•
•
P4325
HONEYWELL
PART NO.
PART NO.
P673-RA889A
P673-R8845A
RA889A1001
R8845U1003
209