Whirlpool Range WFG381LV User Manual

®
30" (76.2 cm) Freestanding Gas Range  
PRODUCT MODEL NUMBERS  
PRODUCT DIMENSIONS  
GFG461LV  
Type of Gas  
Natural Gas:  
WFG381LV  
This range is design-certified by CSA International for use with  
Natural gas or, after proper conversion, for use with LP gas.  
This range is factory set for use with Natural gas. See “Gas  
Conversions” section. The model/serial rating plate located on the  
oven frame behind the top left side of the oven door has  
information on the types of gas that can be used. If the types of  
gas listed do not include the type of gas available, check with the  
local gas supplier.  
LP gas conversion:  
Conversion must be done by a qualified service technician.  
A
No attempt shall be made to convert the appliance from the gas  
specified on the model/serial rating plate for use with a different gas  
without consulting the serving gas supplier. See “Gas Conversions”  
section.  
F
C
B
Gas Supply Line  
Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the range  
location. A smaller size pipe on longer runs may result in  
insufficient gas supply. With LP gas, piping or tubing size can be  
¹⁄₂" (1.3 cm) minimum. Usually, LP gas suppliers determine the  
size and materials used in the system.  
NOTE: Pipe-joint compounds that resist the action of LP gas must  
be used. Do not use TEFLON®† tape.  
E
If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to  
152.4 cm) long, ¹⁄₂" (1.3 cm) or ³⁄₄" (1.9 cm) I.D., flexible metal  
appliance connector may be used for connecting range to the gas  
supply line.  
D
A ¹⁄₂" (1.3 cm) male pipe thread is needed for connection to the  
female pipe threads of the inlet to the appliance pressure regulator.  
Must include a shutoff valve:  
The supply line must be equipped with a manual shutoff valve.  
This valve should be located in the same room but external to the  
range opening, such as an adjacent cabinet. It should be in a  
location that allows ease of opening and closing. Do not block  
access to shutoff valve. The valve is for turning on or shutting off  
gas to the range.  
A. 27¹⁷⁄₃₂" (69.9 cm) max. depth with handle  
B. 36" (91.4 cm) cooktop height (max.) with leveling  
legs screwed all the way in*  
C. 46⁷⁄₈" (119.1 cm) overall height (max.) with  
leveling legs screwed all the way in*  
D. 29⁷⁄₈" (75.9 cm) width  
E. 25" (63.5 cm)  
F. Model/serial rating plate (located on the oven  
frame behind the top left side of the oven door)  
Electrical:  
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is  
required. A time-delay fuse or circuit breaker is also recommended.  
It is recommended that a separate circuit serving only this range be  
provided.  
*Range can be raised approximately 1" (2.5 cm) by adjusting the leveling legs  
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.  
CABINET OPENING DIMENSIONS  
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth,  
24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height.  
IMPORTANT: If installing a range hood or microwave hood combination above  
the range, follow the range hood or microwave hood combination installation  
instructions for dimensional clearances above the cooktop surface.  
D
B
C
A. 18" (45.7 cm) upper side cabinet to countertop  
B. 13" (33 cm) max. upper cabinet depth  
C. 30" (76.2 cm) min. opening width  
D. For minimum clearance to top of cooktop, see NOTE*.  
E. 30¹⁄₈" (76.5 cm) min. opening width  
F. The shaded areas are recommended for installation of rigid gas pipe.  
G. 4¹⁄₂" (11.4 cm)  
A
E
N
H. 8" (20.3 cm)  
M
L
I. 17" (43.2 cm)  
J. 2" (5.1 cm)  
K. 4¹⁄₂" (11.4 cm)  
L. 2" (5.1 cm) min. clearance from both sides of range to side  
wall or other combustible material.  
H
F
G
I
K
F
M. Grounded outlet  
N. Cabinet door or hinges should not extend into the cutout.  
* NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet is covered  
by not less than 1⁄4" (0.64 cm) flame retardant millboard covered with not less than  
No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm)  
aluminum or 0.020" (0.5 mm) copper.  
J
K
30" (76.2 cm) minimum clearance between the top of the cooking platform and the  
bottom of an uncovered wood or metal cabinet.  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. W10413013A  
5-20-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Weider Home Gym 831157070 User Manual
Weil McLain Boiler AFG User Manual
Westinghouse Laptop 190 5300 User Manual
Westinghouse Saw Digtrip RMS 500 User Manual
Whirlpool Clothes Dryer 3979171 User Manual
Whirlpool Microwave Oven GH9185XL User Manual
Williams Furnace 2509621 User Manual
Xantech Electronic Accessory HDMI3X1 User Manual
Yamaha Guitar CGX 111SC User Manual
Zanussi Ventilation Hood TH 500 User Manual