INSTALLATION INSTRUCTIONS
FREESTANDING ELECTRIC RANGE WITH DOUBLE OVENS
Table of Contents
RANGE SAFETY ......................................................................... 2
INSTALLATION REQUIREMENTS............................................ 3
Tools and Parts........................................................................ 3
Location Requirements ........................................................... 3
Electrical Requirements........................................................... 5
INSTALLATION INSTRUCTIONS.............................................. 6
Unpack Range......................................................................... 6
Adjust Leveling Legs................................................................ 6
Install Anti-Tip Bracket ............................................................ 7
Electrical Connection............................................................... 8
Verify Anti-Tip Bracket Location............................................ 13
Level Range........................................................................... 14
Complete Installation............................................................. 14
Moving the Range.................................................................. 15
IMPORTANT:
Save for local electrical inspector's use.
W10270322A
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION REQUIREMENTS
Tools and Parts
Location Requirements
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
IMPORTANT: Observe all governing codes and ordinances.
■
It is the installer’s responsibility to comply with installation
clearances specified on the model/serial number rating label.
The model/serial number rating label is located on the bottom
right front of the toe kick plate.
■
■
■
■
Tape measure
Level
■
■
■
■
Wrench or pliers
³⁄₈" nut driver
■
■
The range should be located for convenient use in the kitchen.
To eliminate the risk of burns or fire by reaching over heated
surface units, cabinet storage space located above the
surface units should be avoided. If cabinet storage is to be
provided, the risk can be reduced by installing a range hood
that projects horizontally a minimum of 5" (12.7 cm) beyond
the bottom of the cabinets.
Phillips screwdriver
Flat-blade screwdriver
Hand or electric drill
¹⁄₈" (3.2 mm) drill bit
Parts supplied
Check that all parts are included.
■
■
Cabinet opening dimensions that are shown must be used.
Given dimensions are minimum clearances.
■
■
■
■
■
3 - 10–32 hex nuts (attached to terminal block)
3 - Terminal lugs
The floor anti-tip bracket must be installed. To install the anti-
tip bracket shipped with the range, see “Install Anti-Tip
Bracket” section.
Oven racks
2 - #12 x 1⁵⁄₈" screws (for mounting anti-tip bracket)
■
Grounded electrical supply is required. See “Electrical
Requirements” section.
Anti-tip bracket (taped inside upper oven with literature
package)
IMPORTANT: To avoid damage to your cabinets, check with your
builder or cabinet supplier to make sure that the materials used
will not discolor, delaminate or sustain other damage. This range
has been designed in accordance with the requirements of UL
and CSA International and complies with the maximum allowable
wood cabinet temperatures of 194°F (90°C).
Anti-tip bracket must be securely mounted to back wall or
floor. Thickness of floor may require longer screws to anchor
bracket to subfloor. Longer screws are available from your
local hardware store.
Parts needed
If using a power supply cord:
Mobile Home - Additional Installation Requirements
■
A UL listed power supply cord kit marked for use with ranges.
The cord should be rated at 250 volts minimum, 40 amps or
50 amps that is marked for use with nominal 1³⁄₈" (3.5 cm)
diameter connection opening and must end in ring terminals
or open-end spade terminals with upturned ends.
The installation of this range must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction and
Safety, Title 24, HUD Part 280). When such standard is not
applicable, the Standard for Manufactured Home Installations,
ANSI A225.1/NFPA 501A or with local codes.
■
A UL listed strain relief.
Mobile home installations require:
Check local codes. Check existing electrical supply. See
“Electrical Requirements” section.
It is recommended that all electrical connections be made by a
licensed, qualified electrical installer.
■
When this range is installed in a mobile home, it must be
secured to the floor during transit. Any method of securing the
range is adequate as long as it conforms to the standards
listed above.
■
Four-wire power supply cord or cable must be used in a
mobile home installation. The appliance wiring will need to be
revised. See “Electrical Connection” section.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Dimensions
Cabinet Dimensions
Cabinet opening dimensions shown are for 25" (64.0 cm)
countertop depth, 24" (61.0 cm) base cabinet depth and
36" (91.4 cm) countertop height.
IMPORTANT: If installing a range hood or microwave hood
combination above the range, follow the range hood or
microwave hood combination installation instructions for
dimensional clearances above the cooktop surface.
A freestanding range may be installed next to combustible walls
with zero clearance.
A
A
B
C
C
D
E*
G
D
F
B
A. 46⁷⁄₈" (119.9 cm)
C. 35⁷⁄₈" (91.4 cm)
D. 29⁷⁄₈" (75.9 cm)
E. 26⁵⁄₁₆" - 27¼" (66.8 - 69.2 cm)*
E
B. Model/serial number rating
label (located on bottom right
front of the toe kick plate)
*Excludes handle. Dimension given is from wall to front of oven
door and will vary based on electric outlet receptacle installation.
H
A. 13" (33 cm) upper cabinet
depth
B. 30" (76.2 cm) min. opening
width
C. For minimum clearance to the
top of the cooktop,
see NOTE.
D. 30" (76.2 cm) min. opening
width
F. 3-wire shaded area -
7" (17.8 cm) min. from left side
cabinet, 5¾" (14.6 cm) max.
from floor, 6" (15.2 cm) max.
width*
G. 4-wire shaded area -
10" (25.4 cm) min. from right
side cabinet, 5¾" (14.6 cm)
max. from floor, 6" (15.2 cm)
max. width*
E. Cabinet door or hinge should
not extend into cutout.
H. 1½" (3.8 cm) min. from floor if
using a flush mount outlet.
*Nothing located in shaded areas can extend more than 1½"
(3.8 cm) from wall or range will not slide all the way back.
NOTE: 24" (61.0 cm) minimum when bottom of wood or metal
cabinet is covered by not less than ¹⁄₄" (0.64 cm) flame retardant
millboard covered with not less than No. 28 MSG sheet steel,
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or
0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking
platform and the bottom of an uncovered wood or metal cabinet.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical Requirements
If codes permit and a separate ground wire is used, it is
If connecting to a 4-wire system:
recommended that a qualified electrical installer determine that
the ground path and wire gauge are in accordance with local
codes.
This range is manufactured with the ground connected to the
neutral by a link. The ground must be revised so the green ground
wire of the 4-wire power supply cord is connected to the cabinet.
See “Electrical Connection.”
Do not use an extension cord.
Grounding through the neutral conductor is prohibited for new
branch-circuit installations (1996 NEC); mobile homes; and
recreational vehicles, or an area where local codes prohibit
grounding through the neutral conductor.
When a 4-wire receptacle of NEMA Type 14-50R is used, a
matching UL listed, 4-wire, 250-volt, 40- or 50-amp, range power
supply cord (pigtail) must be used. This cord contains 4 copper
conductors with ring terminals or open-end spade terminals with
upturned ends, terminating in a NEMA Type 14-50P plug on the
supply end.
Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code, ANSI/NFPA
70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269.
WARNING: Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. Check with a
qualified electrician or service technician if you are in doubt as to
whether the appliance is properly grounded. Do not modify the
power supply cord plug. If it will not fit the outlet, have a proper
outlet installed by a qualified electrician.
The fourth (grounding) conductor must be identified by a green or
green/yellow cover and the neutral conductor by a white cover.
Cord should be Type SRD or SRDT with a UL listed strain relief
and be at least 4 ft (1.22 m) long.
Electrical Connection
To properly install your range, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
■
Range must be connected to the proper electrical voltage and
frequency as specified on the model/serial number rating
label. The model/serial number rating label is located on the
bottom right front of the toe kick plate. Refer to the figures in
the “Product Dimensions” section of the “Location
Requirements” section.
4-wire receptacle (14-50R)
The minimum conductor sized for the copper 4-wire power
cord are:
40-amp circuit
■
This range is manufactured with the neutral terminal
connected to the cabinet. Use a 3-wire, UL listed, 40- or
50-amp power supply cord (pigtail) (see following Range
Rating chart). If local codes do not permit ground through the
neutral, use a 4-wire power supply cord rated at 250 volts,
40 or 50 amps and investigated for use with ranges.
2 No.-8 conductors
1 No.-10 white neutral
1 No.-8 green grounding
If connecting to a 3-wire system:
Local codes may permit the use of a UL listed, 3-wire, 250-volt,
40- or 50-amp range power supply cord (pigtail). This cord
contains 3 copper conductors with ring terminals or open-end
spade terminals with upturned ends, terminating in a NEMA Type
10-50P plug on the supply end. Connectors on the appliance end
must be provided at the point the power supply cord enters the
appliance. This uses a 3-wire receptacle of NEMA Type 10-50R.
Range Rating*
Specified Rating of
Power Supply Cord Kit
and Circuit Protection
120/240 Volts
120/208 Volts
Amps
8.8 - 16.5 KW
16.6 - 22.5 KW
7.8 - 12.5 KW
12.6 - 18.5 KW
40 or 50**
50
*The NEC calculated load is less than the total connected load
listed on the model/serial number rating label.
**If connecting to a 50-amp circuit, use a 50-amp rated cord with
kit. For 50-amp rated cord kits, use kits that specify use with a
nominal 1³⁄₈" (34.9 mm) diameter connection opening.
3-wire receptacle (10-50R)
■
A circuit breaker is recommended.
■
The range can be connected directly to the circuit breaker box
(or fused disconnect) through flexible or nonmetallic sheathed,
copper or aluminum cable. See “Electrical Connection.”
■
■
Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that
the range can be moved if servicing is ever necessary.
A UL listed conduit connector must be provided at each end
of the power supply cable (at the range and at the junction
box).
■
■
Wire sizes and connections must conform with the rating of
the range.
The wiring diagram is located on the back of the range or
inside the storage drawer in a clear plastic bag.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
Unpack Range
Adjust Leveling Legs
1. If range height adjustment is necessary, use a wrench or pliers
to loosen the 4 leveling legs.
WARNING
Excessive Weight Hazard
This may be done with the range on its back or with the range
supported on 2 legs after the range has been placed back to a
standing position.
Use two or more people to move and install range.
Failure to do so can result in back or other injury.
NOTE: To place range back up into a standing position, put a
sheet of cardboard or hardboard in front of range. Using 2 or
more people, stand range back up onto the cardboard or
hardboard.
1. Remove shipping materials, tape and film from the range.
Keep cardboard bottom under range.
2. Remove oven racks and parts package from inside oven.
3. To place range on its back, take 4 cardboard corners from the
carton. Stack one cardboard corner on top of another. Repeat
with the other 2 corners. Place them lengthwise on the floor
behind the range to support the range when it is laid on its
back.
WARNING
4. Using 2 or more people, firmly grasp the range and gently lay
it on its back on the cardboard corners.
5. Pull cardboard bottom firmly to remove.
6. Use an adjustable wrench to loosen the leveling legs.
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
7. Place cardboard or hardboard in front of range. Using 2 or
more people, stand range back up onto cardboard or
hardboard.
Failure to follow these instructions can result in death
or serious burns to children and adults.
2. Adjust the leveling legs to the correct height. Leveling legs can
be loosened to add up to a maximum of 1" (2.5 cm). A
minimum of ³⁄₁₆" (5.0 mm) is needed to engage the anti-tip
bracket.
NOTE: If height adjustment is made when range is standing,
tilt the range back to adjust the front legs, then tilt forward to
adjust the rear legs.
3. When the range is at the correct height, check that there is
adequate clearance under the range for the anti-tip bracket.
Before sliding range into its final location, check that the anti-
tip bracket will slide under the range and onto the rear leveling
leg prior to anti-tip bracket installation.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Install Anti-Tip Bracket
1. Remove the anti-tip bracket that is taped inside the upper
Floor Mounting
oven with the package containing literature.
A
B
2. Determine which mounting method to use: floor or wall.
If you have a stone or masonry floor you can use the wall
mounting method.
3. Determine and mark edge of range in the cutout space. The
mounting bracket can be installed on either the left side or
right side of the cutout. Position mounting bracket in cutout so
that right (or left) edge of the bracket is ¹⁵⁄₁₆" (2.4 cm) from the
marked edge of the range, as shown.
A
B
A. #12 x 1⁵⁄₈" screws
B. Anti-tip bracket
Wall Mounting
C
A. Anti-tip bracket
B. Mark edge of range.
C. ¹⁵⁄₁₆" (2.4 cm)
A
B
4. Drill two ¹⁄₈" (3.0 mm) holes that correspond to the bracket
holes of the determined mounting method. See the following.
A. #12 x 1⁵⁄₈" screws
B. Anti-tip bracket
5. Using the Phillips screwdriver, mount anti-tip bracket to the
wall or floor with the two #12 x 1⁵⁄₈" screws provided.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical Connection - U.S.A. Only
Power Supply Cord
Direct Wire
WARNING
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper or 6 gauge aluminum wire.
Electrically ground range.
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Failure to follow these instructions can result in death,
fire, or electrical shock.
1. Disconnect power.
Style 1: Power supply cord strain relief
2. Use Phillips screwdriver to remove the terminal block cover
screw located on the back of the range. Pull cover down and
toward you to remove cover.
■
Assemble a UL listed strain relief in the opening.
A
A. UL listed strain relief
3. Remove plastic tag holding three 10-32 hex nuts from the
■
■
Feed the power supply cord through the strain relief in the
cord/conduit plate on bottom of range. Allow enough
slack to easily attach the wiring to the terminal block.
middle post of the terminal block.
Tighten strain relief screw against the power supply cord.
4. Add strain relief.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Style 2: Direct wire strain relief
■
Assemble a UL listed conduit connector in the opening.
■
Use Phillips screwdriver to remove screws and slide
cord/conduit plate down and out.
A
B
■
Position cord/conduit plate as shown in the following
illustration.
A. Removable retaining nut
B. Strain relief
■
■
Feed the flexible conduit through the strain relief, allowing
enough slack to easily attach wiring to the terminal block.
Tighten strain relief screw against the flexible conduit.
■
Replace cord/conduit plate and insert screws.
5. Replace back panel and screws on rear of range.
6. Complete installation following instructions for your type of
electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical Connection Options
3. Feed the power supply cord through the strain relief in the
cord/conduit plate on bottom of range. Allow enough slack to
easily attach the wiring to the terminal block.
If your home has:
And you will be
connecting to:
Go to Section:
4-wire receptacle
(NEMA type 14-50R)
A UL listed,
250-volt
4-wire connection:
Power supply cord
A
minimum,
40-amp, range
power supply
cord
B
4-wire direct
A fused
4-wire connection:
Direct wire
disconnect or
circuit breaker
box
5"
(12.7 cm)
3-wire receptacle
(NEMA type 10-50R)
A UL listed,
250-volt
3-wire connection:
Power supply cord
minimum,
40-amp, range
power supply
cord
C
D
3-wire direct
A fused
3-wire connection:
Direct wire
disconnect or
circuit breaker
box
1"
A. Terminal block
(2.5 cm)
B. Ground-link screw
C. Cord/conduit plate
D. Power supply cord wires
3"
(7.6 cm)
4. Use Phillips screwdriver to connect the green ground wire
from the power supply cord to the range with the ground-link
screw. The ground wire must be attached first.
4-wire connection: Power Supply Cord
5. Use ³⁄₈" nut driver to connect the neutral (white) wire to the
Use this method for:
center terminal block post with one of the 10–32 hex nuts.
■
■
■
■
New branch-circuit installations (1996 NEC)
Mobile homes
Recreational vehicles
In an area where local codes prohibit grounding through the
neutral
A
F
1. Part of metal ground strap must be cut out and removed.
B
E
C
A
B
C
D
A. 10–32 hex nut
B. Ground-link screw
C. Line 1 (black)
D. Green ground wire
E. Neutral (center) wire
F. Line 2 (red)
A. Metal ground strap
B. Discard
C. Ground-link screw
6. Connect line 1 (black) and line 2 (red) wires to the outer
terminal block posts with 10-32 hex nuts.
2. Use Phillips screwdriver to remove the ground-link screw from
the back of the range. Save the ground link screw and the end
of the ground-link under the screw.
7. Securely tighten hex nuts.
NOTE: For power supply cord replacement, only use a power
cord rated at 250 volts minimum, 40 amps or 50 amps that is
marked for use with nominal 1³⁄₈" (3.5 cm) diameter
connection opening, with ring terminals and marked for use
with ranges.
8. Replace terminal block access cover.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Securely tighten hex nuts.
3-wire connection: Power Supply Cord
NOTE: For power supply cord replacement, only use a power
cord rated at 250 volts minimum, 40 amps or 50 amps that is
marked for use with nominal 1³⁄₈" (3.5 cm) diameter
connection opening, with ring terminals and marked for use
with ranges.
Use this method only if local codes permit connecting chassis
ground conductor to neutral wire of power supply cord.
1. Feed the power supply cord through the strain relief in the
cord/conduit plate on bottom of range. Allow enough slack to
easily attach the wiring to the terminal block.
5. Replace terminal block access cover.
Direct Wire Installation: Copper or Aluminum Wire
This range may be connected directly to the fuse disconnect or
circuit breaker box. Depending on your electrical supply, make the
required 3-wire or 4-wire connection.
A
1. Strip outer covering back 3" (7.6 cm) to expose wires. Strip
the insulation back 1" (2.5 cm) from the end of each wire.
1"
(2.5 cm)
B
3"
(7.6 cm)
2. Allow enough slack in the wire to easily attach the wiring
terminal block.
C
3. Complete electrical connection according to your type of
D
electrical supply (4-wire or 3-wire connection).
4-wire Connection: Direct Wire
A. Terminal block
Use this method for:
B. Ground-link screw
C. Cord/conduit plate
D. Power supply cord wires
■
■
■
■
New branch-circuit installations (1996 NEC)
Mobile homes
2. Use ³⁄₈" nut driver to connect the neutral (white) wire to the
Recreational vehicles
center terminal block post with one of the 10–32 hex nuts.
In an area where local codes prohibit grounding through the
neutral
1. Part of metal ground strap must be cut out and removed.
A
E
A
B
C
D
B
A. Metal ground strap
B. Discard
C
C. Ground-link screw
A. 10–32 hex nut
B. Line 1 (black)
C. Ground-link screw
D. Neutral (white) wire
E. Line 2 (red)
2. Use Phillips screwdriver to remove the ground-link screw from
the back of the range. Save the ground-link screw and the end
of the ground link under the screw.
3. Connect line 1 (black) and line 2 (red) wires to the outer
terminal block posts with 10-32 hex nuts.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Pull the conduit through the strain relief on cord/conduit plate
on bottom of range. Allow enough slack to easily attach wiring
to the terminal block.
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)
Wire Awg
Torque
8 gauge copper
25 lbs-in. (2.8 N-m)
35 lbs-in. (4.0 N-m)
A
B
C
6 gauge aluminum
5. Use Phillips screwdriver to connect the bare (green) ground
wire to the range with the ground-link screw. The ground wire
must be attached first and must not contact any other
terminal.
6. Use ³⁄₈" nut driver to connect the neutral (white) wire to the
center terminal block post with one of the 10–32 hex nuts.
G
A
G
D
B
F
E
F
A. Terminal block
E. Neutral (white) wire
F. Line 1 (black) wire
G. Bare (green) ground wire
B. Ground-link screw
C. Cord/conduit plate
D. Line 2 (red) wire
D
E
C
4. Attach terminal lugs to line 1 (black), neutral (white), and line
2 (red) wires. Loosen (do not remove) the setscrew on the front
of the terminal lug and insert exposed wire end through
bottom of terminal lugs. Securely tighten setscrew to
A. 10–32 hex nut
B. Line 1 (black)
C. Bare (green) ground wire
D. Ground-link screw
E. Neutral (white) wire
F. Line 2 (red)
G. Terminal lug
XX lbs-in. torque. See Bare Wire Torque Specifications chart.
7. Connect line 1 (black) and line 2 (red) wires to the outer
A
terminal block posts with 10-32 hex nuts.
8. Securely tighten hex nuts.
9. Replace terminal block access cover.
B
C
D
E
A. Terminal lug
B. Setscrew
C. Line 1 (black) wire
D. Neutral (white) wire
E. Line 2 (red) wire
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)
3-wire connection: Direct Wire
Wire Awg
Torque
Use this method only if local codes permit connecting ground
conductor to neutral supply wire.
1. Pull the conduit through the hole and conduit plate on bottom
of range. Allow enough slack to easily attach the wiring to the
terminal block.
8 gauge copper
25 lbs-in. (2.8 N-m)
35 lbs-in. (4.0 N-m)
6 gauge aluminum
3. Use ³⁄₈" nut driver to connect the bare (green) ground wire to
the center terminal block post with one of the 10–32 hex nuts.
A
F
E
A
B
B
C
D
C
A. 10–32 hex nut
B. Line 1 (black)
C. Ground-link screw
D. Bare (green) ground wire
E. Line 2 (red)
F. Terminal lug
D
F
E
A. Terminal block
B. Ground-link screw
C. Cord/conduit plate
D. Line 2 (red) wire
E. Bare (green) ground wire
F. Line 1 (black) wire
4. Connect line 1 (black) and line 2 (red) wires to the outer
terminal block posts with 10-32 hex nuts.
5. Securely tighten hex nuts.
6. Replace terminal block access cover.
2. Attach terminal lugs to line 1 (black), bare (green) ground, and
line 2 (red) wires. Loosen (do not remove) the setscrew on the
front of the terminal lug and insert exposed wire end through
bottom of terminal lugs. Securely tighten setscrew to XX lbs-
in. torque. See Bare Wire Torque Specifications chart.
Verify Anti-Tip Bracket Location
1. Make sure the anti-tip bracket is installed.
■
Look for the anti-tip bracket securely attached to floor or
wall.
A
2. If not direct wired, plug power cord into appropriate outlet.
3. Slide range back so rear range foot is engaged with anti-tip
bracket. Check that the flexible conduit or power supply cord
is not bent.
B
C
D
E
A. Terminal lug
B. Setscrew
C. Line 1 (black) wire
D. Bare (green) ground wire
E. Line 2 (red) wire
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Level Range
Complete Installation
1. Place oven rack in oven.
1. Check that all parts are now installed. If there is an extra part,
go back through the steps to see which step was skipped.
2. Check that you have all of your tools.
2. Place level on oven rack and check levelness of range, first
side to side; then front to back.
3. Dispose of/recycle all packaging materials.
4. Check that the range is level. See “Level Range.”
5. Use a mild solution of liquid household cleaner and warm
water to remove waxy residue caused by shipping material.
Dry thoroughly with a soft cloth. For more information, read
the “Range Care” section of the Use and Care Guide.
6. Read the range Use and Care Guide.
7. Turn power on. Turn on surface burners and oven. See the
Use and Care Guide for specific instruction on range
operation.
3. If range is not level, pull range forward until rear leveling leg is
removed from the anti-tip bracket.
4. Use wrench to adjust leveling legs up or down until range is
If range does not operate, check the following:
level. Push range back into position.
■
Household fuse is intact and tight; or circuit breaker has not
tripped.
5. Check that rear leveling leg is engaged in anti-tip bracket.
NOTE: Range must be level for satisfactory baking performance.
■
■
■
Range is plugged into an outlet.
Electrical supply is connected.
See “Troubleshooting” in the Use and Care Guide.
When the range has been on for 5 minutes, check for heat. If
range is cold, turn off the range and contact a qualified
technician.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Moving the Range
For direct-wired ranges:
WARNING
WARNING
Electrical Shock Hazard
Tip Over Hazard
Disconnect power before servicing.
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
Failure to follow these instructions can result in death
or serious burns to children and adults.
1. Disconnect power.
2. Slide range forward.
3. Complete cleaning or maintenance.
When moving range, slide range onto cardboard or hardboard to
avoid damaging the floor covering.
4. To check that anti-tip bracket is installed, use a flashlight and
look underneath the bottom of the range:
If removing the range is necessary for cleaning or maintenance:
■
Look for the anti-tip bracket securely attached to floor or
wall.
For power supply cord-connected ranges:
1. Slide range forward.
■
Slide range back so rear range foot is under anti-tip
bracket.
2. Unplug the power supply cord.
3. Complete cleaning or maintenance.
4. Plug in power supply cord.
5. To check that anti-tip bracket is installed, use a flashlight and
look underneath the bottom of the range:
■
Look for the anti-tip bracket securely attached to floor or
wall.
■
Slide range back so rear range foot is under anti-tip
bracket.
5. Check that range is level.
6. Reconnect power.
6. Check that range is level.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
W10270322A
© 2009. Whirlpool Corporation.
All rights reserved.
5/09
Printed in U.S.A.