INSTALLATION REQUIREMENTS
SMART-MOUNT® tray assembly installation
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
A
B
C
Tools needed
I
Flat-blade and Phillips
screwdrivers
I
I
I
I
I
Pencil
Tape measure
Level
D
I
I
I
¹⁄₄" nut driver
⁷⁄₁₆" wrench
Scissors
Drill
³⁄₃₂" or smaller drill bit
E
G
H
I
Through-the-Wall Installation
F
J
In addition to the tools listed above, the following tools are
needed for through-the-wall installation.
A. Tray back
B. Tray center
C. Tray sides (2)
D. Support legs (2)
E. #8 - 18 x ¹⁄₄" hex- H. Hex nuts (4)
I
Saw
I
Caulk
head screws (4)
F. Flat washers (4)
G. Lock washers (4)
I. Carriage bolts (4)
J. #10 - 12 x 1¹⁄₂" slot-
head wood screws (2)
I
Wood preservative
I
1" (2.5 cm) or thicker
lumber
Parts supplied
Location Requirements
Check that all parts are included in parts package.
IMPORTANT: Observe all governing codes and ordinances.
Air conditioner installation
Check the location where the air conditioner will be installed.
Make sure you have everything necessary for correct installation.
G
The location should provide:
F
I
Grounded electrical outlet within 4 ft (122 cm) of where the
power cord exits the air conditioner.
NOTE: Do not use an extension cord.
E
H
I
I
Free movement of air in room to be cooled.
A
A large enough opening for the air conditioner. Installation
parts are supplied for double-hung windows.
B
D
C
I
Adequate wall support for weight of air conditioner. Air
conditioner weighs 80 lbs (36.3 kg) to 125 lbs (56.7 kg).
A. Window-lock bracket
B. #8 x ³⁄₈" pan-head screws (6)
C. #8 x ³⁄₄" round-head screws (3)
D. #10 x ³⁄₈" pan-head screws (3)
E. Side curtains (2)
F. Top channel
G. Foam seal
NOTE: Cabinet louvers must not be obstructed. Air must be able
to pass freely through the cabinet louvers.
H. Side curtain frames (2)
A
A. Cabinet louvers
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Window Installation
Electrical Requirements
Window opening measurements:
I
27" (68.6 cm) minimum to 40" (101.6 cm) maximum opening
width.
WARNING
I
19" (48.3 cm) minimum opening height.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
A
B
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
A. 27" (68.6 cm) minimum, 40" (101.6 cm) maximum
B. 19" (48.3 cm) minimum
The electrical ratings for your air conditioner are listed on the
model and serial number label. The model and serial number
label is located on the right-hand side of the cabinet.
Specific electrical requirements are listed in the chart below.
Follow the requirements for the type of plug on the power supply
cord.
Through-the-Wall Installation
The wall opening measurements should be:
Power supply
cord
I
I
I
Height: 18" (45.7 cm) plus twice the thickness of wood used
to build frame.
Wiring requirements
Width: 26" (66 cm) plus twice the thickness of wood used to
build frame.
I
I
I
115-volt (103.5 min. - 126.5 max.)
0-12 amps
Depth: 2" (5 cm) minimum to 8" (20.3 cm) maximum.
15-amp time-delay fuse or circuit
breaker
I
Use on single outlet circuit only.
C
I
I
I
230-volt (207 min. - 253 max.)
0-12 amps
A
¹⁄₄"
(0.6 cm)
B
15-amp time-delay fuse or circuit
breaker
D
I
Use on single outlet circuit only.
C
A. 18" (45.7 cm)
B. 26" (66 cm)
C. Wood thickness
D. 2" (5 cm) minimum to 8" (20.3 cm) maximum
Recommended grounding method
This air conditioner must be grounded. This air conditioner is
equipped with a power supply cord having a grounded 3 prong
plug. To minimize possible shock hazard, the cord must be
plugged into a mating, grounded 3 prong outlet, grounded in
accordance with all local codes and ordinances. If a mating outlet
is not available, it is the customer's responsibility to have a
properly grounded 3 prong outlet installed by a qualified electrical
installer.
It is the customer's responsibility:
I
To contact a qualified electrical installer.
I
To assure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70 -
latest edition, and all local codes and ordinances.
Copies of the standards listed may be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Power Supply Cord
INSTALLATION INSTRUCTIONS
NOTE: Your unit’s device may differ from the one shown.
A
Unpack the Air Conditioner
B
WARNING
Excessive Weight Hazard
Use two or more people to move and install
air conditioner.
Failure to do so can result in back or other injury.
A. Test button
B. Reset button
Remove packaging materials
This room air conditioner is equipped with a power supply cord
required by UL. This power supply cord contains state-of-the-art
electronics that sense leakage current. If the cord is crushed, the
electronics detect leakage current and power will be
disconnected in a fraction of a second.
I
Remove and properly dispose of packaging materials.
Remove tape and glue residue from surfaces before turning
on the air conditioner. Rub a small amount of liquid dish soap
over the adhesive with your fingers. Wipe with warm water
and dry.
I
I
Do not use sharp instruments, rubbing alcohol, flammable
fluids, or abrasive cleaners to remove tape or glue. These
products can damage the surface of your air conditioner.
WARNING
Handle air conditioner gently.
1. Locate provided bag of pan-head screws.
2. Place the top channel on top of the air conditioner, lining up
the holes in top channel with the holes on top of air
conditioner.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
3. Using 3 - #10 x ³⁄₈" pan-head screws, attach top channel to
air conditioner.
B
B
A
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
To test your power supply cord:
1. Plug power supply cord into a grounded 3 prong outlet.
2. Press RESET.
3. Press TEST (listen for click; Reset button will trip and pop
out).
4. Press and release RESET (listen for click; Reset button will
latch and remain in). The power supply cord is ready for
operation.
A. Top channel
B. #10 x ³⁄₈" pan-head screw
NOTES:
I
The Reset button must be pushed in for proper operation.
I
The power supply cord must be replaced if it fails to trip when
the test button is pressed or fails to reset.
I
I
Do not use the power supply cord as an off/on switch. The
power supply cord is designed as a protective device.
A damaged power supply cord must be replaced with a new
power supply cord obtained from the product manufacturer
and must not be repaired.
I
The power supply cord contains no user serviceable parts.
Opening the tamper-resistant case voids all warranty and
performance claims.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Window Installation
1. Using the tray back as a template, center in windowsill
1. To assemble the tray frame, insert tab on tray back into slot
on tray side. Check to see that the tab is engaged and the
2 pieces are aligned. Insert 2 - #8 - 18 x ¹⁄₄" hex-head screws
to secure.
against outside edge of stool.
2. Repeat with other tray side.
C
C
B
B
A
A
A. Tray back
B. Windowsill
C. Outside edge of stool
A. Tray back
B. #8 - 18 x ¹⁄₄" hex-head screws
C. Tray side
2. Using the 2 inside screw holes in tray back, mark
screw locations on windowsill for mounting the
SMART-MOUNT® tray.
Attach Support Legs
1. Determine the correct slots on the tray side from the type of
exterior construction of the building.
Thin Wall Construction (vinyl, wood, etc.)
A
3. Remove tray back. Using these marks, drill ³⁄₃₂" pilot holes in
the windowsill approximately 1¹⁄₂" (3.8 cm) deep.
Assemble SMART-MOUNT® Tray
A. First and second slots
Thick Wall Construction (brick)
A
A. Second and third slots
6
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Insert carriage bolt up through slot on tray-frame side and
Install SMART-MOUNT® Tray Assembly in Window
support leg.
1. From inside, place SMART-MOUNT® tray, support legs facing
down, in the window. Match the holes in tray side with the
predrilled holes in windowsill.
2. Using 2 - #10 - 12 x 1¹⁄₂" slot-head wood screws, secure the
tray frame to the window.
A
3. Place one end of tray center over carriage bolt.
A. #10 - 12 x 1¹⁄₂" slot-head wood screws
NOTE: If the exterior of building can be damaged by support
legs, place a board between the wall and support legs.
3. With tray center pushed away from the windowsill, place a
level on the angled edge on top of the tray side. Be sure level
is against notch on tray side.
B
A
4. Then place flat washer, lock washer and hex nut.
NOTE: Do not tighten. The leg must be able to move freely to
adjust angle when installed.
A
B
C
D
A. Angled edge on top of the tray side
B. Notch
E
4. Adjust SMART-MOUNT® tray until bubble indicates the
A. Hex nut
B. Lock washer
C. Flat washer
D. Tray center
E. Carriage bolt
angled edge on top of the tray side is level.
IMPORTANT: The tray must slope downward slightly toward
the outside to provide proper drainage for the air conditioner.
5. Insert second carriage bolt through tray side and attach other
end of support leg.
NOTE: Do not tighten. The leg must be able to move freely to
adjust angle when installed.
A
A
B
B
C
D
A. Bubble indicates the angled edge on top of the tray side is level.
B. Place level on angled edge against notch on tray side.
A. Hex nut
B. Lock washer
C. Flat washer
D. Carriage bolt
5. Tighten the hex nut just enough to hold tray center in place.
6. Repeat with other side.
7. Tighten hex nuts securely with ⁷⁄₁₆" wrench.
6. Install support leg on other side.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Prepare Air Conditioner for Window Installation
Top View
Install Side Curtains
NOTE: Attach curtains to unit before placing unit in window.
1. Insert curtain into curtain frame. Make sure curtain end locks
into curtain frame.
Top View
Bottom View
Side View
5. Extend right-hand curtain outward so you may insert the first
screw through the middle hole of the curtain. Using a #8 x ³⁄₈"
pan-head screw, screw curtain to middle hole in air
conditioner cabinet.
2. Push curtain in all the way.
3. Pull curtain toward open end of curtain frame.
NOTE: This screw is required to correctly attach curtain (top
to bottom) to the air conditioner cabinet.
4. Insert top and then bottom of right-hand curtain frame in top
A
and bottom curtain guides on air conditioner.
A. #8 x ³⁄₈" pan-head screw
6. While the right-hand curtain is still extended, insert screws
into top and bottom slots of curtain. Using #8 x ³⁄₈" pan-head
screws, screw curtain to the top and bottom holes in air
conditioner cabinet.
7. Slide curtain housing into guides as far as it will go.
8. Repeat above steps for left-hand curtain.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Position the Air Conditioner in Window
I
I
Handle air conditioner gently.
Incorrect Installation
Be sure your air conditioner does not fall out of the opening
during installation or removal.
A
C
B
I
I
Do not block the louvers on the front panel.
B
Do not block the louvers on the outside of the air conditioner.
WARNING
Excessive Weight Hazard
Use two or more people to move and install
air conditioner.
A. Window sash
B. Top channel
C. Air conditioner
Failure to do so can result in back or other injury.
1. Put air conditioner on SMART-MOUNT® tray. Check that feet
on bottom of air conditioner are behind and against back side
of windowsill. Lower window sash.
3. If the bottom of the air conditioner does not sit against the
bottom of the SMART-MOUNT® tray, remove air conditioner
and adjust angle of tray until air conditioner sits against the
bottom of the tray.
IMPORTANT: The tray must slope downward slightly toward
the outside to provide proper drainage for the air conditioner.
A
B
A
B
A. Window sash
B. Feet on bottom of air conditioner
behind back side of windowsill
2. If window sash does not close flush against rear
surface of top channel, remove air conditioner and
adjust SMART-MOUNT® tray until window sash closes
flush against rear surface of top channel.
A. Air conditioner sitting on SMART-MOUNT® tray
B. SMART-MOUNT® tray
IMPORTANT: The tray must slope downward slightly toward
the outside to provide proper drainage for the air conditioner.
Attach Side Curtains to Window
1. Pull left-hand curtain frame out until it fits into the window
Correct Installation
channel. Repeat with right-hand curtain frame.
2. Insert one of the #8 x ³⁄₄" round-head screws through left-
hand curtain frame and into the window channel to fasten the
curtain frame to the window.
A
B
3. Repeat for right-hand curtain frame.
Front View
C
A
B
A. Window sash
B. Top channel
C. Air conditioner
If your air conditioner looks like either of the illustrations in the
“Incorrect installation” graphic, SMART-MOUNT® tray needs
adjustment.
A. Hole for #8 x ³⁄₄" round-head screw
B. Side curtain
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Top View
WARNING
B
A
C
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
A. Side curtain against window channel
B. Window channel
C. #8 x ³⁄₄" round-head screw
Complete Installation
Do not use an extension cord.
1. Insert foam seal behind the top of the lower window sash and
Failure to follow these instructions can result in death,
fire, or electrical shock.
against the glass of the upper window.
A
4. Attach window-lock bracket to window sash with #8 x ³⁄₄"
round-head screw to secure window in place.
B
A
B
A. Lower window sash
B. Foam seal
2. Place window-lock bracket on top of lower window and
against upper window sash.
A. Upper window sash
B. Window-lock bracket
3. Use a ³⁄₃₂" drill bit to drill a starter hole through the hole in the
bracket into the window sash.
5. Plug into a grounded 3 prong outlet.
6. Press RESET on the power supply cord plug.
Through-the-Wall Installation
Option 1—Wood, Metal or Plastic Molding
Option 2—Plaster Wall With No Molding
If the plastered wall is to be flush with the cabinet and no molding
is used, the wood frame must be set ¹⁄₂" (13 mm) into the inside
wall.
When you are using a wood, metal or plastic molding, the wood
frame should line up with inside wall as shown.
A B C
A B
C
D
D
A. Molding
B. Inside wall
C. Wood frame
D. Louvers
A. Plastered wall
B. Inside wall
C. Wood frame
D. Louvers
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Install Wood Frame
A
1. Construct wood frame. See “Location Requirements” for
dimensions.
2. Measure outside width and height of frame to determine wall
opening dimensions.
3. Cut opening through the wall. Remove and save insulation.
B
NOTES:
I
Dimension for depth depends on wall thickness and type
of molding.
I
I
Do not block louvers in air conditioner cabinet.
Use 1" (2.5 cm) or thicker lumber for wood frame.
A. Inside screw holes
B. Indoor side of wall opening
A
9. Remove the tray back. Using these marks, drill ³⁄₃₂" pilot holes
approximately 1¹⁄₂" (3.8 cm) deep.
B
Assemble SMART-MOUNT® Tray
C
A. Outside width
B. Outside height
C. Depth
4. Apply wood preservative to the outside exposed surface.
5. Insert the frame in the wall opening. Square and level frame.
6. Attach frame securely to the wall.
7. Place a ³⁄₄" (2 cm) thick by 2" (5 cm) wide wood strip on the
bottom of the opening against the inside edge.
A
D
1. To assemble the tray frame, insert tab on tray back into slot
on tray side. Check to see that the tab is engaged and the
2 pieces are aligned. Insert 2 - #8 - 18 x ¹⁄₄" hex-head screws
to secure.
C
B
A. 17¹⁄₄" (43.8 cm)
B. 2" (5 cm) wide
C. ³⁄₄" (2 cm) thick
2. Repeat with other tray side.
D. Indoor side of wall opening
C
8. Center the tray back in the opening and align it with the inside
edge of the opening. Using the 2 inside screw holes in the
tray back, mark screw locations for mounting the
SMART-MOUNT® tray.
B
A
A
A. Tray back
B. #8 - 18 x ¹⁄₄" hex-head screws
C. Tray side
A. Flush with inside wall
11
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Then place flat washer, lock washer and hex nut.
Attach Support Legs
NOTE: Do not tighten. The leg must be able to move freely to
adjust angle when installed.
1. Determine the correct slots on the tray side from the type of
exterior construction of the building.
A
B
C
D
Thin wall construction (vinyl, wood, etc.)
A
E
A. Hex nut
D. Tray center
B. Lock washer
C. Flat washer
E. Carriage bolt
A. First and second slots
5. Insert second carriage bolt through tray side and attach other
end of support leg.
Thick wall construction (brick)
NOTE: Do not tighten. The leg must be able to move freely to
adjust angle when installed.
A
A
B
C
D
A. Second and third slots
2. Insert carriage bolt up through slot on tray-frame side and
A. Hex nut
B. Lock washer
C. Flat washer
D. Carriage bolt
support leg.
6. Install support leg on other side.
Install SMART-MOUNT® Tray Assembly in Wall Opening
1. From inside, place SMART-MOUNT® tray, support legs facing
down, in the wall opening. Match the holes in tray side with
the predrilled holes in wall opening.
3. Place one end of tray center over carriage bolt.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Using 2 - #10 - 12 x 1¹⁄₂" slot-head wood screws, secure the
B
A
tray-frame assembly to the wall opening.
Left Side
A. Angled edge on top of the tray side
B. Notch
4. Adjust SMART-MOUNT® tray until bubble indicates the
angled edge on top of the tray side is level.
A
IMPORTANT: The tray must slope downward slightly toward
the outside to provide proper drainage for the air conditioner.
A. #10 - 12 x 1¹⁄₂" slot-head wood screw
Right Side
A
B
A
A. Bubble indicates the angled edge on top of the tray side is level.
B. Place level on angled edge against notch on tray side.
A. #10 - 12 x 1¹⁄₂" slot-head wood screw
NOTE: If the exterior of building can be damaged by support
5. Tighten the hex nut just enough to hold tray center in place.
6. Repeat with other side.
legs, place a board between the wall and support legs.
3. With tray center pushed away from the windowsill, place a
level on the angled edge on top of the tray side. Be sure level
is against notch on tray side.
7. Tighten hex nuts securely with ⁷⁄₁₆" wrench.
Position the Air Conditioner Through the Wall
I
I
Handle air conditioner gently.
Be sure your air conditioner does not fall out of the opening
during installation or removal.
I
I
Do not block the louvers on the front panel.
Do not block the louvers on the outside of the air conditioner.
WARNING
Excessive Weight Hazard
Use two or more people to move and install
air conditioner.
Failure to do so can result in back or other injury.
B
1. Place the air conditioner in the SMART-MOUNT® tray. Check
that feet on bottom of air conditioner are resting on the ³⁄₄"
(1.9 cm) x 2" (5 cm) wood strip at the bottom of the wall
opening and the top channel rests against the top of the wall
opening.
A
A. SMART-MOUNT® tray
B. Feet on bottom of air conditioner resting on wood strip
13
Download from Www.Somanuals.com. All Manuals Search And Download.
2. If the feet on the bottom of the air conditioner do not rest on
the wood strip, remove the air conditioner and adjust the
SMART-MOUNT® tray until feet rest on the wood strip.
and adjust angle of tray until air conditioner sits against the
bottom of the tray.
IMPORTANT: The tray must slope downward slightly toward
the outside to provide proper drainage for the air conditioner.
A
B
A
B
C
A. Air conditioner
B. Feet on bottom of air conditioner
C. ³⁄₄" (1.9 cm) x 2" (5 cm) wood strip
A. Air conditioner sitting on SMART-MOUNT® tray
B. SMART-MOUNT® tray
5. Install screws through the top channel to secure the air
3. If top channel does not rest against the top of the wall
opening, remove air conditioner and adjust SMART-MOUNT®
tray until top channel rests against wall.
conditioner into the wall opening.
Complete Installation
IMPORTANT: The tray must slope downward slightly toward
the outside to provide proper drainage for the air conditioner.
1. Trim and seal around the air conditioner on the inside and the
outside.
A
NOTE: Allow for removal of the air conditioner at a later time
for routine annual maintenance.
B
WARNING
C
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
A. Top of wall opening
B. Top channel
C. Air conditioner
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
2. Plug into a grounded 3 prong outlet.
3. Press RESET on the power supply cord plug.
4. If the bottom of the air conditioner does not sit against the
bottom of the SMART-MOUNT® tray, remove air conditioner
14
Download from Www.Somanuals.com. All Manuals Search And Download.
AIR CONDITIONER USE
Operating your air conditioner properly helps you to obtain the
best possible results.
I
Do not try to operate your air conditioner in the cooling mode
when outside temperature is below 65°F (18°C). The inside
evaporator coil will freeze up, and the air conditioner will not
operate properly.
This section explains proper air conditioner operation.
IMPORTANT:
I
If you turn off the air conditioner, wait at least 3 minutes
before turning it back on. This prevents the air conditioner
from blowing a fuse or tripping a circuit breaker.
NOTE: In the event of a power failure, your air conditioner will
operate at the previous settings when the power is restored.
Starting Your Air Conditioner—Digital Control
I
Cool—Cools room. You can adjust temperature by
pressing the plus or minus button. You can select fan
speed by pressing FAN SPEED.
I
Fan Only—Only the fan runs. You can select the fan
speed by pressing FAN SPEED, but you cannot adjust the
Temperature control setting. Display shows the current
room temperature.
I
Power Saver—Fan runs only when cooling is needed. You
can select the fan speed by pressing FAN SPEED.
Because the fan does not circulate the room air
continuously, less energy is used, but the room air is not
circulated as often. Use Power Saver when you are
asleep or away from home.
NOTES:
I
When the air conditioner is off, the Room indicator light is lit
and the display shows the current room temperature.
I
If the room temperature is below 55ºF (13ºC), the display will
show 55ºF (13ºC). If the room temperature is above 99ºF
(37ºC), the display will show 99ºF (37ºC).
Fan Speed
I
I
When the Set indicator light is lit, the display shows the
NOTE: The Fan Speed button will operate only when Cool, Fan
temperature control setting. See “Temperature.”
Only or Power Saver mode has been selected.
1. Press FAN SPEED until you see the indicator light come on
When the Hour indicator light is lit, the display shows the time
remaining on the Timer setting. See “Timer Delay.”
for the setting you desire.
2. Choose Turbo, High or Low.
1. Remove clear protective film from control panel and front
panel badge.
2. Press POWER to turn on air conditioner.
Filter Monitor
NOTE: When air conditioner is turned on for the first time
after it is plugged in, it will display the default settings: Cool
mode, Turbo fan speed, 72°F (22°C) for 3 seconds. When it is
turned on at all other times, it will display the previous
settings for 3 seconds, and then display the room
temperature.
1. When Filter indicator light is lit or flashing, remove, clean and
replace air filter. See “Cleaning the Air Filter.”
2. Press and hold FILTER for 3 seconds after cleaning and
replacing the air filter. This resets the Filter Monitor.
3. Select mode. See “Mode.”
4. Select fan speed. See “Fan Speed.”
5. Set temperature. See “Temperature.”
Mode
NOTE: After 360 hours of fan operating time, the Filter indicator
light will turn on. It will remain on for 180 hours or until you press
FILTER. After 180 hours, it will flash. It will continue flashing until
you press FILTER.
1. Press MODE until you see the indicator light come on for the
setting you desire.
2. Choose Auto, Cool, Fan Only or Power Saver.
I
Auto—Cools room while it automatically controls fan
speed. You cannot change fan speed, but you can adjust
temperature by pressing the plus or minus button.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
To set the Timer to turn on the air conditioner, keeping
previous settings:
Temperature
1. Turn off air conditioner.
I
Press the plus button to raise the temperature. Room
indicator light will turn off, and Set indicator light will turn on.
Display shows the Temperature control setting. Each time you
press or hold the plus button, the temperature will increase
1º until it reaches 86°F (30°C).
2. Press TIMER. Timer indicator light will flash. Hour indicator
light will turn on, and display will show remaining hours
before air conditioner will turn on.
3. Press the plus or minus button to change delay time (1 to
24 hours).
NOTE: After 3 seconds, Set indicator light will turn off, and
Room indicator light will turn on. Display will show the current
room temperature.
4. Press TIMER again or wait 10 seconds. Timer indicator light
will remain on. Hour indicator light will turn off, and Room
indicator light will turn on. Display will show current room
temperature.
To set the Timer to turn on the air conditioner, changing
the previous settings:
1. Turn on air conditioner.
2. Adjust Mode to Auto, Cool, Fan Only, or Power Saver.
NOTE: For Auto mode, go to Step 4.
3. For Cool, Fan Only or Power Saver mode, adjust FAN SPEED
I
Press the minus button to lower the temperature. Room
indicator light will turn off, and Set indicator light will turn on.
Display shows the Temperature control setting. Each time you
press or hold the minus button, the temperature will decrease
1º until it reaches 64°F (18°C).
to Turbo, High or Low.
4. Adjust temperature between 64°F (18ºC) and 86°F (30ºC).
5. Wait 3 seconds before turning off air conditioner.
6. Press TIMER. Timer indicator light will flash. Hour indicator
light will turn on, and display will show remaining hours
before air conditioner will turn on.
NOTE: After 3 seconds, Set indicator light will turn off, and
Room indicator light will turn on. Display will show the current
room temperature.
7. Press the plus or minus button to change delay time (1 to
24 hours).
To change the temperature display from °F to °C:
1. Turn off the air conditioner.
8. Press TIMER again or wait 10 seconds. Timer indicator light
will remain on. Hour indicator light will turn off, and Room
indicator light will turn on. Display will show current room
temperature.
2. While the air conditioner is off, press and hold down the
MODE and FAN SPEED buttons while pressing POWER to
turn on the air conditioner.
To clear Timer delay program:
NOTE: Air conditioner can be either on or off.
Press and hold TIMER for 3 seconds. Timer indicator light will
shut off.
NOTE: Follow these same steps to change the temperature
display from °C to °F.
Timer Delay
To see or change the remaining time (in hours):
1. Press TIMER once after it has been programmed. Hour
indicator light will turn on, and display will show remaining
time.
To set the Timer for a 1- to 24-hour delay until the air
conditioner turns off (the air conditioner must be On):
1. Press TIMER. Timer indicator light will flash. Hour indicator
light will turn on, and display will show remaining hours
before air conditioner will turn off.
2. While the display is showing the remaining time, you can
press the plus or minus button to increase or decrease the
time.
3. After 10 seconds, Hour indicator light will turn off, and Room
indicator light will turn on. Display will show the current room
temperature.
2. Press the plus or minus button to adjust the delay time (1 to
24 hours).
3. Press TIMER again or wait 10 seconds. Timer indicator light
will remain on. Hour indicator light will turn off, and Room
indicator light will turn on. Display will show the current room
temperature.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
To raise the temperature:
To Operate Air Conditioner with Remote Control
Press the plus button. Room indicator light on air conditioner will
turn off, and Set indicator light on air conditioner will turn on.
Display on air conditioner shows the Temperature control setting.
Each time you press or hold the plus button, the temperature will
increase 1º until it reaches 86°F (30ºC).
NOTE: Remote control may vary in appearance.
NOTE: After 3 seconds, Set indicator light on air conditioner will
turn off, and Room indicator light on air conditioner will turn on.
Display on air conditioner will show the current room
temperature.
To lower the temperature:
Press the minus button. Room indicator light on air conditioner
will turn off, and Set indicator light on air conditioner will turn on.
Display on air conditioner shows the Temperature control setting.
Each time you press or hold the minus button, the temperature
will decrease 1º until it reaches 64°F (18ºC).
NOTE: After 3 seconds, Set indicator light on air conditioner will
turn off, and Room indicator light on air conditioner will turn on.
Display on air conditioner will show the current room
temperature.
To set the Timer for a 1- to 24-hour delay until the air
conditioner turns off (the air conditioner must be On):
1. Press TIMER. Timer indicator light on air conditioner will
flash. Hour indicator light on air conditioner will turn on, and
display on air conditioner will show remaining hours before air
conditioner will turn off.
NOTE: Two AA batteries (not included) power the remote control.
Replace batteries after 6 months of use, or when the remote
control starts to lose power.
To turn the air conditioner on or off:
Press POWER.
2. Press the plus or minus button to change delay time (1 to
24 hours).
3. Press TIMER again or wait 10 seconds. Timer indicator light
on air conditioner will remain on. Hour indicator light on air
conditioner will turn off, and Room indicator light on air
conditioner will turn on. Display on air conditioner will show
the current room temperature.
To select the mode:
Press AUTO COOL, COOL, FAN ONLY, or POWER SAVER.
I
Auto Cool—fan speed is adjusted automatically.
I
Cool, Fan Only or Power Saver—you can adjust the fan
speed.
To set Timer to turn on air conditioner, keeping previous
settings:
1. Turn off air conditioner.
2. Press TIMER. Timer indicator light on air conditioner will
flash. Hour indicator light on air conditioner will turn on, and
display on air conditioner will show remaining hours before air
conditioner will turn off.
3. Press the plus or minus button to change delay time (1 to
24 hours).
4. Press TIMER again or wait 10 seconds. Timer indicator light
on air conditioner will remain on. Hour indicator light on air
conditioner will turn off, and Room indicator light on air
conditioner will turn on. Display on air conditioner will show
the current room temperature.
To select the fan speed (in Cool, Fan Only or Power Saver
mode only):
Press TURBO, HIGH or LOW.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Press TIMER. Timer indicator light on air conditioner will
flash. Hour indicator light on air conditioner will turn on, and
display on air conditioner will show remaining hours before air
conditioner will turn on.
To set Timer to turn on air conditioner, changing the
previous settings:
1. Turn on air conditioner.
2. Adjust Mode to Auto Cool, Cool, Fan Only, or Power Saver.
NOTE: For Auto Cool mode, go to Step 4.
7. Press the plus or minus button to change delay time (1 to
24 hours).
3. For Cool, Fan Only or Power Saver mode, adjust Fan Speed
8. Press TIMER again or wait 10 seconds. Timer indicator light
on air conditioner will remain on. Hour indicator light on air
conditioner will turn off, and Room indicator light on air
conditioner will turn on. Display on air conditioner will show
current room temperature.
to Turbo, High or Low.
4. Adjust temperature between 64°F (18ºC) and 86°F (30ºC).
5. Wait 3 seconds before turning off air conditioner.
Starting Your Air Conditioner—Rotary Control
Models Without Power Saver
Exhaust Control (on some models)
Push the Exhaust control CLOSED for maximum continuous
cooling. Pull the Exhaust control OPEN to allow you to draw stale
or smoky air from the room.
I
Open—pull to exhaust room air to the outside
Closed—push to circulate room air
I
Models With Power Saver
NOTE: The Exhaust control will function only when the Fan
Speed control is operating.
Fan Speed
Set FAN SPEED to the desired setting. When the air conditioner
is operating at Low Cool, High Cool, or Turbo Cool, the fan
circulates air continuously.
1. Remove clear protective film from front panel badge (on
some models).
I
I
I
I
Turbo Cool—for maximum cooling
High Cool—for normal cooling
2. Set exhaust control. See “Exhaust Control (on some
models).”
3. Select the fan speed. See “Fan Speed.”
4. Select temperature. See “Temperature.”
Low Cool—for sleeping comfort
Fan Only—to move air continuously without cooling
NOTE: Fan runs on Turbo speed only.
I
Power Saver (on some models)—fan runs only when cooling
is needed.
Because the fan does not circulate the room air continuously,
less energy is used, but the room air is not circulated as
often. Use Power Saver when you are asleep or away from
home.
NOTE: Fan runs on Low speed only.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Models Without Power Saver
Changing Air Direction
Roll the wheel to direct the air right or left. Rotate the whole
cartridge to direct air up, down or straight ahead.
A
Models With Power Saver
A. Wheel
A
A. Cartridge
Temperature
Normal Sounds
Turn the TEMPERATURE control to a mid-setting. Adjust the air
conditioner's performance by turning the Temperature control
clockwise for maximum cooling. For less cooling, turn the
TEMPERATURE control counterclockwise. Experiment to find the
setting that suits you best.
When your air conditioner is operating normally, you may hear
sounds such as:
I
Droplets of water hitting the condenser, causing a pinging or
clicking sound. The water droplets help cool the condenser.
I
I
I
I
Air movement from the fan.
Clicks from the thermostat cycle.
Vibrations or noise due to poor wall or window construction.
A high-pitched hum or pulsating noise caused by the modern
high-efficiency compressor cycling on and off.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
AIR CONDITIONER CARE
Your new air conditioner is designed to give you many years of
3. Use a vacuum cleaner to clean air filter. If air filter is very dirty,
wash it in warm water with a mild detergent. Do not wash air
filter in the dishwasher or use any chemical cleaners. Air dry
filter completely before replacing to ensure maximum
efficiency.
dependable service. This section tells you how to clean and care
for your air conditioner properly. Call your local authorized dealer
for an annual checkup. Remember… the cost of this service call
is your responsibility.
4. Replace air filter by sliding filter back into either side of unit.
Cleaning the Air Filter
The air filter is removable for easy cleaning. A clean filter helps
remove dust, lint, and other particles from the air and is important
for best cooling and operating efficiency. Check the filter every
2 weeks to see whether it needs cleaning.
Cleaning the Front Panel
1. Turn off air conditioner.
2. Remove the air filter and clean it separately. See “Cleaning
the Air Filter.”
NOTE: Do not operate the air conditioner without the filter in
3. Wipe the front panel with a soft, damp cloth.
4. Air dry front panel completely.
place.
1. Turn off air conditioner.
2. Remove air filter by sliding filter out from either side of unit.
Repairing Paint Damage
Check once or twice a year for paint damage. This is very
important, especially in areas near oceans or where rust is a
problem. If needed, touch up with a good grade enamel paint.
A
NOTE: To reduce paint damage during the winter, install a heavy-
duty cover over air conditioner cabinet. For information on
ordering a heavy-duty cover, see “Accessories.”
Annual Maintenance
Your air conditioner needs annual maintenance to help ensure
steady, top performance throughout the year. Call your local
authorized dealer to schedule an annual checkup. The expense
of an annual inspection is your responsibility.
A. Filter may be removed from either side.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING
Before calling for service, try the suggestions below to see whether you can solve your problem without outside help.
Air conditioner will not operate
Air conditioner blows fuses or trips circuit breakers
I
I
I
Too many appliances are being used on the same circuit.
Unplug or relocate appliances that share the same circuit.
WARNING
An extension cord is being used. Do not use an extension
cord with this or any other appliance.
You are trying to restart the air conditioner too soon after
turning the unit off. Wait at least 3 minutes after turning the
unit off before trying to restart the air conditioner.
Air conditioner power supply cord trips (Reset button
pops out)
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
I
I
Disturbances in your electrical current can trip (Reset
button will pop out) the power supply cord. Press and
release RESET (listen for click; Reset button will latch and
remain in) to resume operation.
Do not use an extension cord.
Electrical overloading, overheating, cord pinching or
aging can trip (Reset button will pop out) the power
supply cord. After correcting the problem, press and release
RESET (listen for click; Reset button will latch and remain in)
to resume operation.
Failure to follow these instructions can result in death,
fire, or electrical shock.
I
I
The power supply cord is unplugged. Plug into a grounded
3 prong outlet. See “Electrical Requirements.”
NOTE: A damaged power supply cord must be replaced with a
new power supply cord obtained from the product manufacturer
and must not be repaired.
Time-delay fuse or circuit breaker of the wrong capacity
is being used. Replace with a time-delay fuse or circuit
breaker of the correct capacity. See “Electrical
Requirements.”
Air conditioner seems to run too much
I
I
The power supply cord has tripped (Reset button has
popped out). Press and release RESET (listen for click; Reset
button will latch and remain in) to resume operation.
I
The current air conditioner replaced an older model. The
use of more efficient components may cause the air
conditioner to run longer than an older model, but the total
energy consumption will be less. Newer air conditioners do
not emit the “blast” of cold air you may be accustomed to
from older units, but this is not an indication of lesser cooling
capacity or efficiency. Refer to the efficiency rating (EER) and
capacity rating (in BTU/hr.) marked on the air conditioner.
A household fuse has blown, or a circuit breaker has
tripped. Replace the fuse, or reset the circuit breaker. If the
problem continues, call an electrician. See “Electrical
Requirements.”
I
I
Depending on model, the Power button has not been
pressed or the Fan Speed control is turned to Off. Press
POWER button or turn the Fan Speed control to an active
setting.
I
The air conditioner is in a heavily occupied room, or heat-
producing appliances are in use in the room. Use exhaust
vent fans while cooking or bathing and try not to use heat-
producing appliances during the hottest part of the day. A
higher capacity air conditioner may be required, depending
on the size of the room being cooled.
The local power has failed. Wait for power to be restored.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
I
The temperature of the room you are trying to cool is
extremely hot. Allow extra time for the air conditioner to cool
off a very hot room.
Air conditioner cycles on and off too much or does not
cool
I
I
I
Windows or doors to the outside are open. Close all
I
I
The Mode is set to Power Saver (on some models). Use
Power Saver only when you are asleep or away from home,
since the fan does not circulate the room air continuously.
Use Low, High or Turbo for your best comfort.
windows and doors.
The Exhaust control is set to OPEN (on some models).
Push the Exhaust control CLOSED for maximum cooling.
Depending on model, the Temp/Time or Temperature
control is not at a cool enough setting. Adjust the TEMP/
TIME control to a cooler setting by pressing the minus button
to reduce the temperature, or adjust the Temperature control
to a cooler setting by turning the knob clockwise. Set the Fan
Speed control to Turbo or Turbo Cool.
The air conditioner is not properly sized for your room.
Check the cooling capabilities of your room air conditioner.
Room air conditioners are not designed to cool multiple
rooms.
I
I
The filter is dirty or obstructed by debris. Clean the filter.
The inside evaporator and outside condenser coils are
dirty or obstructed by debris. See “Annual Maintenance.”
Temperature on display does not match room
temperature
I
There is excessive heat or moisture (open container
cooking, showers, etc.) in the room. Use a fan to exhaust
heat or moisture from the room. Try not to use heat-
producing appliances during the hottest part of the day.
I
When the compressor and fan motor turn off during
Power Saver mode, or after you turn off the unit, a lower
temperature reading than the actual room temperature
may be displayed for a short period of time. This lower
temperature reading is caused by the temperature sensor
being located close to the cold evaporator coil. The actual
room temperature will be displayed within a few minutes.
I
I
The louvers are blocked. Install the air conditioner in a
location where the louvers are free from curtains, blinds,
furniture, etc.
The outside temperature is below 65°F (18°C). Do not try to
operate your air conditioner in the cooling mode when the
outside temperature is below 65°F (18°C).
Water drips from cabinet into your house
I
The air conditioner is not properly leveled. The air
conditioner should slope slightly downward toward the
outside. Level the air conditioner to provide a downward
slope toward the outside to ensure proper drainage. See the
Installation Instructions.
NOTE: Do not drill a hole into the bottom of the metal base
and condensate pan.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
ASSISTANCE OR SERVICE
Before calling for assistance or service, please check
“Troubleshooting.” It may save you the cost of a service call. If
you still need help, follow the instructions below.
If you need replacement parts
If you need to order replacement parts, we recommend that you
use only factory-authorized replacement parts. These
replacement parts will fit right and work right because they are
made with the same precision used to build every new appliance.
When calling, please know the purchase date and the complete
model and serial number of your appliance. This information will
help us to better respond to your request.
To locate factory-authorized replacement parts in your area, call
our Customer eXperience Center or your nearest designated
service center.
In the U.S.A.
Call the Customer eXperience Center toll free: 1-800-253-1301.
Please include a daytime phone number in your correspondence.
Our consultants provide assistance with:
Please record your model's information.
I
I
I
I
I
Features and specifications on our full line of appliances.
Whenever you call to request service on your appliance, you
need to know your complete model number and serial number.
You can find this information on the model and serial number
label. See “Electrical Requirements” for model and serial number
location.
Installation information.
Use and maintenance procedures.
Accessory and repair parts sales.
Please record the model and serial number information below.
Also, record the purchase date of your appliance and the store's
name, address, and telephone number.
Specialized customer assistance (Spanish speaking, hearing
impaired, limited vision, etc.).
I
Referrals to local dealers, repair parts distributors, and
service companies. Our service technicians are trained to
fulfill the product warranty and provide after-warranty service,
anywhere in the United States.
Model Number__________________________________________________
Serial Number __________________________________________________
Purchase Date__________________________________________________
Store Name ____________________________________________________
Store Address __________________________________________________
Store Phone ____________________________________________________
Keep this book and the sales slip together for future reference.
To locate the authorized service company in your area, you
can also look in your telephone directory Yellow Pages.
For further assistance
If you need further assistance, you can write with any questions
or concerns at:
Customer eXperience Center
553 Benson Road
Benton Harbor, MI 49022-2692
Accessories
You can order the following accessories for your air conditioner from your local authorized dealer or by calling 1-800-253-1301 from
anywhere in the U.S.A.
Replacement air filters
Heavy-duty cover
A good, clean air filter is important for best cooling with least
energy consumption. Your air filter should be cleaned regularly.
See “Cleaning the Air Filter” for cleaning instructions. We suggest
you replace your air filter once a year.
For a new electrostatic air filter, order Part Number 1187197.
Airborne particles are attracted to an electrostatic air filter and
remain attached to it until they are rinsed away. For a new
antimicrobial air filter, order Part Number 1187389. In addition to
providing all the benefits of an electrostatic air filter, an
antimicrobial air filter also inhibits the growth of odor-causing
bacteria, fungi, mold and mildew on the filter. Both of these air
filters are sized to fit your air conditioner.
If you decide to leave your air conditioner installed during the
winter, a heavy-duty cover will help protect your air conditioner
and reduce drafts. The outdoor cover protects against cold drafts
through the unit's air passages and protects the cabinet from
snow, rain, sleet, rust, and dust.
For a heavy-duty outdoor cover sized to fit your air conditioner,
order Part Number 484069.
For a heavy-duty indoor cover sized to fit your air conditioner,
order Part Number 4392941.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
1188226B
© 2005.
12/05
Printed in U.S.A.
SMART-MOUNT is a trademark of Whirlpool, U.S.A.
All rights reserved.
Download from Www.Somanuals.com. All Manuals Search And Download.
|