ELECTRIC FIREPLACE
CARE & USE GUIDE
Please read this manual before
installing and using your fireplace
IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, AN ELECTRICAL SHOCK
OR FIRE MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE
Download from Www.Somanuals.com. All Manuals Search And Download.
Use this appliance only as described in this manual. Any other use not recommended
by the manufacturer may cause fire, electric shock or injury to persons.
Avoid the use of an extension cord because the extension cord may overheat and
cause a risk of fire. However, if you have to use an extension cord, the cord shall be
14 gauge minimum size and rated not less that 2025 watts. The extension cord must
be a three wire cord with grounding type plug and cord connector. The extension
cord shall not be more than 20 feet in length.
17.
18.
SPECIFICATIONS
Dimensions LxWxH
15.76” x 26” x 28.37”
59.40 lbs
110V
Net Weight
Voltage
Frequency
Watts
60 Hz
1350 W
Heater Rating
4600 BTU
ELECTRICAL CONNECTION
A 15 Amp, 110 Volt, 60 Hz circuit with a properly grounded outlet is required to operate this
appliance. The fireplace must be on a dedicated circuit as other appliances on the same
circuit may cause the circuit breaker to trip or the fuse to blow when the heater is in opera-
tion. The unit comes standard with a 6.5 ft long 3 wire cord, exiting out the back of the
fireplace. Plan the installation to avoid the use of an extension cord. If an extension cord
must be used, it must be a minimum 14 gauge, 3 wire with grounding type plug and
connector and rated not less than 2025 watts. The extension cord shall not be more than
20 ft in length.
WARNING: Electrical outlet wiring must comply with local building codes and other
applicable regulations to reduce the risk of fire, electrical shock and injury to persons.
WARNING: Do not use this fireplace if any part of it has become wet. Immediately call a
qualified service technician to inspect the fireplace and replace any part of the electrical
system which has been wet.
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICE INSTRUCTIONS
FOR YOUR SAFETY
Service must be performed by a qualified service agency.
REtPLACING THE LIGHT BULBS
This fireplace uses 2 clear 110 Volt, 40 Watt, E-12 socket base light bulbs (small base,
chandelier candle type bulbs). The access plate is located on the back of the unit. For
convenience, if one of the light bulbs burns out, it may be easier to replace both of the
light bulbs at the same time.
WARNING: Do not exceed 40 Watts per bulb. Use of higher rated bulbs may result in a
fire, causing property damage, personal injury or loss of life.
1. Turn off the power to the unit, and unplug it from the electrical outlet.
2. Let the fireplace cool if it has been operating.
3. Turn the fireplace so you are facing the back of the fireplace.
4. Look for the access plate with the gold printing on it.
5. Remove the 3 screws holding the access plate in position. Once you have removed
the 3 screws, lift the access plate so the 2 positioning tabs come free of their slots.
Once you have removed the access plate you can see and access the two 40 watt
chandelier bulbs.
6. Remove each light bulb by unscrewing them out of the bases, turning them
counterclockwise. You can use one hand to hold the light socket in place, if required.
7. Install the new light bulbs by turning each light bulb into the base clockwise. You can
use one hand to hold the light socket in place, if required.
8. Replace the access plate by inserting the 2 tabs, pushing the plate up against the
fireplace back, and inserting the 3 screws.
9. Turn the fireplace back so you are facing the front of the fireplace.
10. Plug the fireplace back into the electrical outlet and turn the power on and enjoy the
flame effect.
SERVICE INSTRUCTIONS
Your fireplace has the following functions:
Leg Assembly:
Lay stove on a flat surface. Attach
4 legs with screws provided as
shown in Fig. 1:
Low heat
700 watts
On/Off
Power to the uni
High heat
1350 watts
Fig. 1
Please note: Both the low heat and high heat
Download from Www.Somanuals.com. All Manuals Search And Download.
switches must be in the on position to achieve high heat.