Weber Thermometer 178722 User Manual

Digital Pocket thermometer With  
StainleSS Steel Probe  
NOTE Please keep this manual handy as you use your new product. It contains practical step-by-step instructions, as well as technical specifications and warnings you should know about. Do not use a dishwasher to clean the  
probe or immerse in water or liquid. Clean the probe with water and a mild detergent. Wipe the cabinet with a damp cloth.  
FEATURES  
TEMPERATURE MEASUREMENT  
USING THE AUTO POWER OFF AND POWER OFF FUNCTIONS  
1. Pull out the Pocket Thermometer from the plastic sleeve.  
Press the [AUTO-OFF] button. This enables “AUTO” to display, indicating  
the thermometer will turn off automatically. If you do not press any key for  
6 to 7 minutes, the thermometer will turn off automatically.  
Easy operation:  
Displays the temperature reading automatically.  
2. Pierce the sensor probe into meat or place the sensor probe into water.  
Press and hold the [ON/FAST] button for a faster sensing rate, the  
measuring temperature will show on the display in a second. The  
temperature sensing rate will operate at its normal speed if you do not  
press the [ON/FAST] button.  
Error-free Reading: Digital display system ensures clear, error-free  
reading at a glance.  
If you press the [AUTO-OFF] button once again, the thermometer will turn  
off immediately.  
Wide Range:  
User Friendly:  
Measuring range from -50°C to 260°C  
(-58°F to 500°F)  
Caution: The effective measuring area is 1.5"–2" from the tip.  
User selectable normal or fast sampling cycle.  
Plastic sleeve for sensor probe protection.  
SPECIFICATIONS  
Do not expose the main unit out of the operating temperature.  
Caution: Do not leave the thermometer in the food on the grill.  
Operation temperature  
:
:
0°C - 50°C (32°F - 122°F)  
TEMPERATURE DISPLAY  
AUTO - OFF  
Temperature measuring range (probe)  
-50°C to 260°C  
(-58°F - 500°F)  
USING THE MAXIMUM AND MINIMUM  
TEMPERATURE MEMORY  
Temperature display resolution  
:
Min 0.1°C to Max 0.5°C  
(Min 0.2°F to Max 1°F)  
STAINLESS STEEL PROBE  
1.5"–2"  
Temperature sampling cycle  
(Normal)  
The Pocket Thermometer will automatically record the maximum and minimum  
measurements.  
You can recall those readings by doing the following:  
:
:
:
:
:
:
10 seconds  
MAX/MIN  
(Fast)  
2 seconds  
EFFECTIVE  
MEASURING AREA  
Power Source  
Battery life  
One (1) LR-44 battery  
Approximate 6 Months  
Diameter 2.8 mm ∞ 110 mm  
30g (with plastic sleeve)  
FUNCTION  
CURRENT ACTION  
DISPLAY  
NEXT  
DISPLAY  
ON/FAST  
BATTERY COVER  
Metal probe size  
Weight  
Recall the  
Maximum  
temperature  
22.3  
Press [MAX/MIN] once  
s 28.8  
Recall the  
Minimum  
s 28.8  
Press [MAX/MIN] once  
again  
t18.8  
temperature  
Return to current t18.8  
temperature  
Press [MAX/MIN] once  
again  
22.3  
METAL CLIP  
PLASTIC SLEEVE  
WARRANTY  
RESETTING THE MAXIMUM OR MINIMUM  
TEMPERATURE MEMORIES  
Weber-Stephen Products Co., (Weber®) hereby warrants to the ORIGINAL  
PURCHASER of this Digital Pocket Thermometer, that it will be free  
from defects in material and workmanship from the date of purchase as  
follows: 2 year(s) when assembled, and operated in accordance with the  
printed instructions accompanying it.  
INSTALLING AND REPLACING BATTERIES  
The unit uses 1 LR-44 size battery which is included in the package.  
Follow these steps to install or replace battery:  
The Pocket Thermometer will automatically record the maximum and minimum  
measurements.  
You can reset those readings by doing the following:  
Weber may require reasonable proof of your date of purchase.  
THEREFORE, YOU SHOULD RETAIN YOUR SALES RECEIPT  
OR INVOICE.  
1. Use a screw driver to open the battery cover. (Follow the direction of  
the arrow.)  
FUNCTION  
CURRENT ACTION  
DISPLAY  
NEXT  
DISPLAY  
2. Insert a new battery (make sure positive (+) is facing you).  
This Limited Warranty shall be limited to the repair or replacement of  
parts that prove defective under normal use and service and which on  
examination shall indicate, to Weber’s satisfaction, that they are defective.  
If Weber confirms the defect and approves the claim, Weber will elect to  
repair or replace such parts without charge. If you are required to return  
defective parts, transportation charges must be prepaid. Weber will return  
parts to the purchaser, freight or postage prepaid.  
Reset the  
Maximum  
temperature  
memory  
s 28.8  
Press and hold  
s 22.3  
3. Replace the battery cover.  
(With the  
Maximum  
temperature  
display)  
[ON/FAST] button for 1  
second.  
(The current  
temperature  
will become  
the maximum  
memory)  
DISPLAY MODES  
The thermometer has three different display modes:  
Reset the  
Minimum  
temperature  
memory  
t18.8  
Press and hold  
[ON/FAST] button for 1  
second.  
t22.3  
(With the  
Minimum  
temperature  
display)  
(The current  
temperature  
will become  
the minimum  
memory)  
This Limited Warranty does not cover any failures or operating difficulties  
due to accident, abuse, misuse, alteration, misapplication, vandalism,  
improper installation or improper maintenance or service, or failure to  
perform normal and routine maintenance. Deterioration or damage due  
to severe weather conditions such as hail, hurricanes, earthquakes or  
tornadoes, discolouration due to exposure to chemicals either directly or  
in the atmosphere, is not covered by this Limited Warranty. Weber shall not  
be liable under this or any implied warranty for incidental or consequential  
damages. This warranty gives you specific legal rights, and you may also  
have other rights, which vary from state to state.  
DISPLAY MODE  
FUNCTION  
DISPLAY  
22.3  
Normal  
Shows the current measuring  
temperature.  
Return to current t22.3  
temperature  
Press [MAX/MIN] once  
22.3  
Maximum Temperature  
Memory  
Shows the maximum temperature  
recorded since last memory reset.  
s 28.8  
t18.8  
Minimum Temperature  
Memory  
Shows the minimum temperature  
recorded since last memory reset.  
NOTE: You may like to clear the memory occasionally, so you can record  
the Maximum / Minimum for a specified period.  
Auto Power OFF  
The thermometer will  
AUTO 22.3  
Weber Customer Service (US only) 1-800-446-1071.  
Resetting a memory will result in the current temperature being  
displayed in the Maximum or Minimum memory display.  
automatically turn off, if you do not  
press any key for 6 to 7 minutes.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
178722 8/07  

Technicolor Thomson MP3 Player PDP2860 User Manual
TeleAdapt Switch TA 6500 User Manual
Toastmaster Coffeemaker MERB10B User Manual
Toshiba Blu ray Player BDX2150KC User Manual
Toshiba Cash Register MA 1300 User Manual
Toshiba Tablet Accessory AT300SE User Manual
Trane Thermostat TCONT401AN21MA User Manual
Viking Burner F50028 User Manual
VistaQuest Digital Camera VQ3015 User Manual
Vulcan Hart Range VCH16 ML 126341 User Manual