GAS GRILL
Built-In LP Gas Grill Installation Guide
Tank Enclosure Installation - Pg 25
S-460™
S-660™
#43267
YOU MUST READ THIS OWNER’S GUIDE
BEFORE OPERATING YOUR GAS GRILL
ƽ WARNING: Follow all leak-check procedures
carefully in this manual prior to barbecue
operation. Do this even if the barbecue was
dealer-assembled.
ƽ DANGER
If you smell gas:
NOTICE TO INSTALLER: These instructions
must be left with the owner and the owner
should keep them for future use.
1. Shut off gas to the appliance.
2. Extinguish any open flames.
3. Open lid.
4. If odor continues, keep away from the
appliance and immediately call your gas
supplier or your fire department.
Leaking gas may cause a fire or explosion
which can cause serious bodily injury or death,
or damage to property.
THIS GAS APPLIANCE IS DESIGNED FOR
OUTDOOR USE ONLY.
ƽ WARNING: Do not try to light this appliance
without reading the “Lighting Instructions”
section of this manual.
ƽ WARNING:
1. Do not store or use gasoline or other
flammable liquids or vapors in the vicinity of
this or any other appliance.
2. An LP cylinder not connected for use shall
not be stored in the vicinity of this or any
other appliance.
43267 US 08/06/08
LP
Download from Www.Somanuals.com. All Manuals Search And Download.
3
BUILT-IN CUTOUT DIMENSIONS
BUILT-IN STRUCTURE CUTOUT DIMENSIONS
ALL DIMENSIONS ARE TO FINISHED SURFACES.
BUILT-IN CUTOUT DIMENSIONS
3
S-460™
S-660™
1
TOLERANCES
ƽ
WARNING: All countertop finished surfaces must be
constructed of a noncombustible material.
1
1
1
1
1
1
1
1
2
3
30
34
/
˝ (768.35 mm)
38
34
/
˝ (971.55 mm)
+
+
+
/
/
/
˝
˝
˝
-
-
-
/
/
/
˝ (6.35mm)
˝ (6.35mm)
˝ (6.35mm)
4
4
4
4
4
4
4
4
3
3
/
˝ (873.13 mm)
/
˝ (873.13 mm)
8
8
23˝ (584.2 mm)
23˝ (584.2 mm)
GENERAL CONSTRUCTION DETAILS
Summit® Built-In unit and all other accessory units should be on site before construction
begins.
1
All dimensions have a tolerance of plus or minus (+/-)
/
inch (6.35 mm).
4
The grill frame rests directly on the Island Structure top finished surface. Make
sure this surface is level. Do not support the grill from the bottom.
If the supporting structure is going to have an electrical outlet for a
rotisserie, it should be on the left side of the structure.
BUILT-IN CUTOUT DIMENSIONS
S-460™
S-660™
1
2
3
4
5
6
24” minimum* (610 mm)
4 3/4” (120.65 mm)
6 1/4” (158.75 mm)
24” minimum* (610 mm)
4 3/4” (120.65 mm)
6 1/4” (158.75 mm)
10 1/2” (266.7 mm) minimum
23” (584.2 mm)
10 1/2” (266.7 mm) minimum
23” (584.2 mm)
34 3/8” (873.13 mm)
34 3/8” (873.13 mm)
27” (685.8 mm) minimum distance from front edge of
the cutout for open lid clearance
27” (685.8 mm) minimum distance from front edge of
the cutout for open lid clearance
7
8
a
b
c
d
30 1/4” (768.35 mm) Built-In Frame
38 1/4” (971.55 mm) Built-In Frame
Note: For a countertop treatment: Recommended 3/4” (19.1 mm) overhang. Notch front edge for frame to fully slide in.
Gas Inlet
Side Burner Opening
Access for electric on left hand side
* Clearance from any surface or structure is at least 24” (609.6mm) from the back and sides of the grill or side burner.
WWW.WEBER.COM®
Download from Www.Somanuals.com. All Manuals Search And Download.
4
PARTS LIST
S-460™
Lid - 1
Left Door - 1
Cookbox - 1
Right Door - 1
Warming Rack - 1
OR
S-660™
Lid - 1
Right Enclosure Panel - 1
Cookbox - 1
Left Enclosure Panel - 1
Front Frame Rail - 1
Rear Frame Rail - 1
Front Vent Panel - 1
Rear Panel Assembly - 1
Rear Vent - 1
Bottom Shelf - 1
Corrugated Gas Line - 1
WWW.WEBER.COM®
Download from Www.Somanuals.com. All Manuals Search And Download.
5
PARTS LIST
Flavorizer® Bars
Smoker - 1
5
S-460™
S-660™
- 8
- 12
Stainless Steel Cooking Grates
Smoker Bar - 1
S-460™
- 2
S-660™
- 3
1/2 inch Bolts (¼-20 x 1/2 inch Bolt) - 10
Collection Tray - 1
Nylon Washer - 10
Hinge Pin - 2
Catch-Pan Holder - 1
Catch-Pan - 1
Hair Pin Cotter - 2
Disposable Drip Pans - 2
Battery Housing - 1
#10-32 x 1/4 inch Steel Screw - 5
¼-20 x 1/2 inch Truss Head Screw - 2
#10 Sheet Metal Screw - 3
Right Front Vent Clip - 1
Left Front Vent Clip - 1
Flat Head Screw - 2
Plastic Anchors - 5
Rotisserie - 1
Keps Nuts (1/4 x 20 Keps Nut) - 2
Rotisserie Fork - 4
1 inch Bolt (¼-20 x 1 inch Bolt) - 2
Handle Hardware - 4
Rotisserie Motor - 1
Rotisserie Bracket - 1
Handle - 2
Wire Tie - 1
7/16 inch Wrench - 1
WWW.WEBER.COM®
Download from Www.Somanuals.com. All Manuals Search And Download.
6
ASSEMBLY
1
2
1
2
1
Arrow stickers
on Frame Rail
(1) and Left Side
Panel (2) should
point toward each
other (shown
above). Door Stop
Bracket (3) should
be positioned as
shown (left).
3
2
WWW.WEBER.COM®
Download from Www.Somanuals.com. All Manuals Search And Download.
7
ASSEMBLY
7
3
ƽ ATTENTION! Do not fully tighten screws.
Clips should slide freely when installed.
4
WWW.WEBER.COM®
Download from Www.Somanuals.com. All Manuals Search And Download.
8
ASSEMBLY
5
6
Back
WWW.WEBER.COM®
Download from Www.Somanuals.com. All Manuals Search And Download.
9
ASSEMBLY
9
7
WWW.WEBER.COM®
Download from Www.Somanuals.com. All Manuals Search And Download.
10
ASSEMBLY
ƽ
CAUTION: Use two people to lift and install the Summit® Built-In frame assembly.
A)
B)
Lift the frame assembly into the “island” structure opening. Make sure the frame is resting level on the finished surface of the structure.
Adjust the Front Vent to rest squarely on ground.
8
CLEARANCES
24" (610 mm) Any Surface
1
Grill Frame
a
Note: For a countertop treatment: Recommended 19.1 mm (3/4˝
inch) overhang. Notch front edge for frame to fully slide in.
b
WWW.WEBER.COM®
Download from Www.Somanuals.com. All Manuals Search And Download.
11
ASSEMBLY
11
9
1/4" (6.35 mm)
Drill Bit
A)
Apply a bead of silicone sealant (1) around
the perimeter and front edges of the grill that
are in contact with the “island” structure. This
will prevent moisture seepage. The sealant
you use must have a temperature rating
above 120°F (48.8° C).
A
10
(1)
S-460™
S-660™
ƽ ATTENTION! Before applying
any silicone sealant make
sure the cookbox is flush with
the front of the grill frame.
WWW.WEBER.COM®
Download from Www.Somanuals.com. All Manuals Search And Download.
ASSEMBLY
12
F ))#œ
S-460™
11
3 -
2
1
BATTERY HOUSING WIRING
1
BLACK WIRE
GREEN WIRE
RED WIRE
2
3
4
4
3
RED WIRE
ƽ
WARNING: Make sure that all control knobs are turned to the OFF
position before connecting the gas supply and operating the grill.
WWW.WEBER.COM®
Download from Www.Somanuals.com. All Manuals Search And Download.
13
ASSEMBLY
Requires 3“D”alkaline batteries (Included). Use alkaline
batteries only. Do not mix old and new batteries or different types
of batteries (standard, alkaline or rechargeable).
13
12
13
Note: Secure wire to side panel.
(1)
(2)
(3)
WWW.WEBER.COM®
Download from Www.Somanuals.com. All Manuals Search And Download.
14
ASSEMBLY
14
S-460™
S-660™
15
16
S-460™
S-660™
WWW.WEBER.COM®
Download from Www.Somanuals.com. All Manuals Search And Download.
15
ASSEMBLY
S-460™
S-660™
15
17
A
B
C
Match Holder
WWW.WEBER.COM®
Download from Www.Somanuals.com. All Manuals Search And Download.
16
ASSEMBLY
18
ƽ ATTENTION!
Before drilling
any holes for the
rear vent make
sure the cookbox
is flush with the
front of the grill
frame.
1/4" (6.35 mm)
Drill Bit
WWW.WEBER.COM®
Download from Www.Somanuals.com. All Manuals Search And Download.
17
ASSEMBLY
S-460™
S-660™
17
19
20
S-460™
S-660™
WWW.WEBER.COM®
Download from Www.Somanuals.com. All Manuals Search And Download.
18
ASSEMBLY
21
S-460™
S-660™
S-460™
S-660™
22
WWW.WEBER.COM®
Download from Www.Somanuals.com. All Manuals Search And Download.
19
ASSEMBLY
S-460™
S-660™
19
23
WWW.WEBER.COM®
Download from Www.Somanuals.com. All Manuals Search And Download.
ASSEMBLY
20
S-460™
S-660™
24
WWW.WEBER.COM®
Download from Www.Somanuals.com. All Manuals Search And Download.
21
ASSEMBLY
21
S-460™
S-460™
S-660™
- 2
AAA
AAA
AAA
- 1
- 2
25
S-660™ - 4
The Weber Grill Out™ Handle Light has a “Tilt Sensor”: Lid up - ON / Lid Closed - OFF. The power
button (a) activates or deactivates the “Tilt Sensor.” For daytime use, deactivate the sensor by
pressing power button (a).
Requires 3 “AAA” alkaline batteries
(not included)
S-660™
WWW.WEBER.COM®
Download from Www.Somanuals.com. All Manuals Search And Download.
22
GAS SUPPLY
BUILT-IN GAS LINE LOCATIONS
BUILT-IN GAS LINE LOCATIONS
Note: Leave an access in the “island” structure for gas supply and regulator service
that is not inside the grill structure. Note: Area should be kept clear of sharp, jagged, or
extremely abrasive surfaces to avoid possible damage to gas supply lines. Exercise
caution when pulling gas lines through built-in structure.
460
660
TOLERANCES
4 3/4˝
(120.65 mm)
4 3/4˝
(120.65 mm)
+1/8˝(3.8mm)
- 1/8˝(3.8mm)
1
2
3
6 1/4˝
(158.8 mm)
6 1/4˝
(158.8 mm)
+1/8˝(3.8mm)
- 1/8˝(3.8mm)
2 1/2˝
(63.5 mm)
2 1/2˝
(63.5 mm)
+1/8˝(3.8mm)
- 1/8˝(3.8mm)
Plan View Left
a
b
c
Side View
Gas Inlet
TYPICAL BULK PROPANE GAS SUPPLY INSTALLATION
We recommend that this installation be done by a LICENSED professional.
ƽ
CAUTION: If young children are in the area, a locking valve
should be considered.
Pipe compound should be used which is resistant to the action of liquid propane
gas when gas connections are made.
GENERAL SPECIFICATIONS FOR PIPING
Note - Contact your local municipality for building codes regulating outdoor gas grill
installations. In absence of Local Codes, you must conform to the latest edition of the
National Fuel Gas Code ANSI Z223.1/NFPA 54, Natural Gas and Propane Installation
•
•
The gas connections must be firmly attached to rigid, permanent construction.
Note:The information provided in this manual is general for typical installations.We
cannot cover all possible installation ideas.We recommend, prior to installation, that you
contact your municipality for local building codes and your local fire department for
installation verification.
Code, CSA B149.1, or Propane Storage and Handling Code, B149.2, or the Standard for
Recreational Vehicles,ANSI A 119.2/NFPA 1192, and CSA Z240 RV Series, Recreational
Vehicle Code, as applicable.
•
This grill is designed to operate at 11 inches of water column pressure. An LP in line
regulator may be necessary for this pressure.
If you have any questions, contact Customer Service at 1-800-446-1071.
WWW.WEBER.COM®
Download from Www.Somanuals.com. All Manuals Search And Download.
23
GAS SUPPLY
Table
6.2(a)
Maximum Capacity of Metallic Pipe in Cubic Feet of Gas per Hour for Gas Pressures of 2 psi or Less and
a Pressure Drop of 0.3 Inch Water Column. (Based on a 0.60 Specific Gravity Gas)
23
Nominal
Iron Pipe
Size
Actual
ID:
(Inches)
Length of Pipe (Feet)
10
20
30
40
50
60
70
80
90
100
125
150
175
200
(Inches)
1/2
3/4
1
.622
.824
131
273
90
72
151
62
55
50
46
95
42
89
40
83
38
79
33
70
30
63
28
26
188
129
114
104
58
54
1.049
1.380
1.610
2.067
2.469
3.068
4.026
514
353
284
243
215
195
179
167
157
148
131
119
109
102
1 1/4
1/12
2
1,060
1,580
3,050
4,860
8,580
726
583
499
442
400
368
343
322
304
269
244
224
209
313
1,090
2,090
3,340
5,900
873
747
662
600
552
514
482
455
403
366
336
1,680
2,680
4,740
1,440
2,290
4,050
8,270
1,280
2,030
3,590
7,330
1,160
1,840
3,260
6,640
1,060
1,690
3,000
6,110
989
928
877
777
704
648
602
960
1,700
3,460
2 1/2
3
1,580
2,790
5,680
1,480
2,610
5,330
1,400
2,470
5,040
1,240
2,190
4,460
1,120
1,980
4,050
1,030
1,820
3,720
4
17,500 12,000 9,660
© 2008 National Fire Protection Association, Inc. and International Approval Services - U.S., Inc. All Rights Reserved.
TEST CONNECTIONS
ƽ DANGER
All connections and joints must be thoroughly tested for leaks in accordance with local
codes and all listed procedures in the latest edition of the National Fuel Gas Code ANSI
Z223.1/NFPA 54, Natural Gas and Propane Installation Code, CSA B149.1, or Propane
Storage and Handling Code, B149.2, or the Standard for Recreational Vehicles, ANSI A
Do not use an open flame to check for gas leaks. Be sure
there are no sparks or open flames in the area while you
check for gas leaks.This will result in a fire or explosion
which can cause serious bodily injury or death, and damage
to property.
119.2/NFPA 1192, and CSA Z240 RV Series, Recreational Vehicle Code, as applicable.
WWW.WEBER.COM®
Download from Www.Somanuals.com. All Manuals Search And Download.
24
GAS SUPPLY
TYPICAL 20 LP PROPANE GAS SUPPLY INSTALLATION
The remote tank enclosure kit provide with you grill shall be used for installations using a
20 lb LP cylinder, mounted in an “island” structure.
The remote tank enclosure shall house the included hose and regulator assembly and
gas connections, the tank bracket and the fuel scale for connecting a remote mounted
LP cylinder to the Summit® Built-In gas grill. The hose and regulator is listed as a required
part of the CSA listed Summit® Built-In gas grill.
A properly installed tank enclosure meets the requirements for venting, tank retention
and separation of the LP cylinder from a heat source as outlined in the ANSI Standard for
Outdoor Cooking Gas Appliances, Z21.58/CSA 1.6 for LP enclosures.
You need to hire a licensed contractor or licensed plumber and they need to follow the
requirements described in the ANSI Standard for Outdoor Cooking Gas Appliances,
Z21.58/CSA 1.6 for LP enclosures.
D) The remote LP cylinder enclosure should be constructed with non-combustible
materials. The remote LP cylinder enclosure should isolate the LP cylinder from the
burner compartment, so that it provides shielding from radiation, be a flame barrier
and provide protection from foreign material such as hot drippings.
E) There should be a minimum of 2 inches (50.8mm) between the ground and the floor of
the remote LP cylinder enclosure.
F) The LP cylinder valve should be readily accessible for hand operation. A door on the
remote LP cylinder enclosure to gain access to the LP cylinder valve is acceptable,
provided it is non-locking and can be opened without the use of tools.
ƽ DANGER
The requirements described in the Standard for Outdoor Cooking Gas Appliances,
Z21.58/CSA 1.6. are as follows;
Use of any other hose and regulator assembly could be
dangerous, and may not provide adequate gas supply to
the Summit® Built-In gas grill, and could result in a fire or an
explosion causing serious bodily injury or death, and damage
to property.
A remote enclosure for an LP gas cylinder shall be ventilated by openings at both the
upper and lower levels of the cylinder. This shall be accomplished by one of the following:
A) One side of the remote LP cylinder enclosure shall be completely open; or
B) If the remote LP cylinder enclosure is designed to have four sides, a top and a bottom,
ventilation is required for the remote LP cylinder enclosure;
1) There should be at least two ventilation openings, (a hole or group of
holes, for the purpose of ventilation) in the sidewalls of the island structure.
The openings should be located within 5 inches (127mm) of the top of the
enclosure. The ventilation openings should be equally sized and spaced at a
minimum of 90 degrees, and be unobstructed. The openings shall have a total
free open area of not less than 20 square inches. (This relates to 1 square
inch of ventilation area, per pound of stored fuel capacity).
2) Ventilation openings (a hole or group of holes, for the purpose of ventilation)
should be provided at floor level. The ventilation openings should have a total
free area of not less than 10 square inches. (This relates to 1/2 square inch of
ventilation area, per pound of stored fuel capacity). There should be at least
two ventilation openings if the ventilation openings at floor level are in the
sidewall. The ventilation openings should be within 5 inches (127mm) of the
floor. The ventilation openings should be of equal size and be spaced at a
minimum of 90 degrees, and should be unobstructed.
ƽ DANGER
Failure to build a remote LP cylinder enclosure for a 20 lb
cylinder following the requirements for ventilation, cylinder
retention and separation of the LP cylinder from a heat
source, listed in the ANSI Standard for Outdoor Cooking Gas
Appliances, ANSI Z21.58 CSA 1.6, could be dangerous, and
could result in a fire or an explosion causing serious bodily
injury or death and damage to property.
If you do not follow the DANGER statements exactly, the Warranty on the Summit® Built-In
gas grill will be voided.
3) The minimum size of the ventilation hole (s) should not be less than 1/4 inch.
4) The ventilation openings in the sidewalls should not allow venting into
the empty or “hollow” area of the “island”. If a gas leak should occur or
the LP cylinder should vent in the LP cylinder enclosure, the gas should
not be allowed to vent or migrate into the empty or “hollow” area of the
“island”. Ventilation openings in the sidewalls of the enclosure should only
communicate with the outside of the “island” structure, so that the gas can
dissipate outside of the “island” structure.
C) If the remote LP cylinder enclosure has four sides, a top and a bottom, and is intended
for installation in a built-in “island” enclosure;
1) At least one ventilation opening (a hole or group of holes, for the purpose
of ventilation) needs to be on one side of the enclosure that communicates
with the outside of the “island” structure. If a gas leak should occur or the
LP cylinder should vent in the LP cylinder enclosure, the gas should not
be allowed to vent or migrate into the empty or “hollow” area of the “island”.
Ventilation openings should only communicate with the outside of the “island”
structure, so that the gas can dissipate outside of the “island” structure. The
ventilation opening should be located within 5 inches (127mm) of the top of
the enclosure, and should have a total free area of 20 square inches. (This
relates to 1 square inch of ventilation area, per pound of stored fuel).
2) At least one ventilation opening (a hole or group of holes, for the purpose of
ventilation) needs to be on one side of the enclosure that communicates with
the outside of the “island” structure, at the bottom. If a gas leak should occur
or the LP cylinder should vent in the LP cylinder enclosure, the gas should
not be allowed to vent or migrate into the empty or “hollow” area of the “island”.
Ventilation openings should only communicate with the outside of the “island”
structure, so that the gas can dissipate outside of the “island” structure. The
ventilation opening should be located within 5 inches (127mm) of the bottom
of the enclosure, and should have a total free area of 10 square inches. (This
relates to 1/4 square inch of ventilation area, per pound of stored fuel).
3) The minimum size of the ventilation hole (s) should not be less than 1/4 inch
(6.35mm).
WWW.WEBER.COM®
Download from Www.Somanuals.com. All Manuals Search And Download.
25
BUILT-IN TANK ENCLOSURE INSTRUCTIONS
25
OPERATING
ƽ WARNING: Only use the Weber® Tank Enclosure Kit outdoors
in a well-ventilated area. Do not use in a garage, building,
breezeway or any other enclosed area.
ƽ WARNING:Turn off the gas at the LP gas supply cylinder
when the outdoor cooking gas appliance is not in use.
ƽ WARNING: Never store an outdoor cooking gas appliance
indoors unless the LP cylinder is disconnected and removed
from the outdoor cooking gas appliance.
ƽ WARNING: LP Cylinders must be stored outdoors out of
the reach of children and must not be stored in a building,
garage, or any other enclosed area.
ƽ WARNING:Your Weber® Tank Enclosure Kit shall not be used
under an unprotected combustible roof or overhang.
ƽ WARNING:Your Weber® Tank Enclosure Kit is not intended to
be installed in or on recreational vehicles and/or boats.
ƽ WARNING: Keep any electrical supply cord and the fuel
supply hose away from any heated surface.
ƽ WARNING:The LP pressure regulator and hose assembly
supplied with the Weber® Tank Enclosure Kit must be used.
Replacement LP pressure regulators and hoses must be
obtained from Weber-Stephen Product Co.
ƽ WARNING: Never store an extra (spare) LP cylinder under or
near the Weber® gas barbecue.
ƽ WARNING: Keep the ventilation openings of the cylinder
enclosure free and clear of debris.
WWW.WEBER.COM®
Download from Www.Somanuals.com. All Manuals Search And Download.
26
BUILT-IN TANK ENCLOSURE INSTRUCTIONS
LOCATINGYOUR LP TANK ENCLOSURE KIT
ƽDANGER
When determining a suitable location for your LP Tank Enclosure Kit installation, give
attention to concerns such as proximity to traffic paths, and keeping any gas supply
lines as short as possible. Never locate the Summit® LP Tank Enclosure Kit in a garage,
breezeway, shed, under an unprotected overhang, or other enclosed area. Locate the LP
Tank Enclosure Kit and structure so there is enough room to safely evacuate the area in
case of a fire.
Use of any other hose and regulator assembly could be
dangerous, and may not provide adequate gas supply to
the Summit® Built-In gas grill, and could result in a fire or an
explosion causing serious bodily injury or death and damage
to property.
c
1
ƽ DANGER
Failure to build a LP cylinder enclosure for a 20 lb cylinder
following the requirements for ventilation, cylinder retention
and separation of the LP cylinder from a heat source, listed in
the ANSI Standard for Outdoor Cooking Gas Appliances, ANSI
Z21.58 CSA 1.6, could be dangerous, and could result in a fire
or an explosion causing serious bodily injury or death and
damage to property.
b
b
1
1
a
If you do not follow the DANGER statements exactly, the Warranty on the Summit®
Built-In gas grill will be voided.
ENCLOSURE CHART
24˝ inches (610 mm) Any Surface
1
LP Tank Enclosure
Any Surface
a
b
c
Non-Combustible Surface
CLEARANCE FROM COMBUSTIBLE SURFACES OR
STRUCTURES
ƽ
WARNING: Clearance from the outside walls of the sides
and back of the LP Tank Enclosure must be a minimum of
24" (60.96cm) any surface. Refer to “Typical Gas Supply
Installation” before starting installation.
ƽ
WARNING:The structure, “island” counter tops and adjacent
work areas for the LP Tank Enclosure must be built from
noncombustible materials only.
NOTE: If you have questions on what materials are considered noncombustible, contact
you local building supplier or fire department.
WWW.WEBER.COM®
Download from Www.Somanuals.com. All Manuals Search And Download.
27
PARTS LIST / ASSEMBLY
PARTS LIST
27
1
Hose and regulator - 1
4
8
4
Tank stand - 1
Tank stand base - 1
Tank Scale - 1
2
1/4-20 nut - 6
Nylon washer - 12
2
4
1/4-20 x 1/2” bolt - 6
Cylinder glide - 2
1/2” Flare Gasket - 2
3/8” Flare Gasket - 2
2
2
WWW.WEBER.COM®
Download from Www.Somanuals.com. All Manuals Search And Download.
28
ASSEMBLY
MOUNTING THE LP TANK BRACKET
Mount the LP tank bracket to the right hand side of the enclosure opening using non corrosive hardware. Mounting holes are provided on the sides and bottom of your LP tank bracket.
Be sure to mount the bracket securley to the enclosure before use.
MOUNTING HARDWARE NOT INCLUDED.
MOUNTING THE LP HOSE AND REGULATOR
Securley mount the hose and regulator bracket to the top of the built-in tank enclosure using non corrosive hardware.
3
MOUNTING HARDWARE NOT INCLUDED.
LP TANK ENCLOSURE GAS LINE LOCATIONS
Area should be kept clear of sharp, jagged, or extremely abrasive surfaces to avoid possible damage to gas supply lines. Exercise caution when pulling gas lines through built-in
structure.
4
WWW.WEBER.COM®
Download from Www.Somanuals.com. All Manuals Search And Download.
29
GAS SUPPLY
CONNECT GAS SUPPLY
29
A 58 inch (147.32 cm) corrugated gas line is supplied with the grill. This line needs to pass
through the gas inlet opening to the main gas supply.
1) Connect the corrugated gas line to the manifold located on the right hand side of grill
under the control panel. Use the 1/2” flared gasket (1) to ensure proper seal.
Note: 1/2”flared gaskets are included in the Summit® Built-In tank Enclosure Kit included
with your grill.
The corrugated line passes through the “Island Structure” cavity to the hose and regulator
connection inside the tank enclosure. (Shown in illustration)
2) Uncap one flare fitting from the 90º Connection on the regulator hose located inside
the tank enclosure.
3) Use the 1/2 (12.7 mm) inch flared gasket to ensure proper seal.
NOTE: Only use the 3/8 inch (9.53 mm) flared gasket if you are installing the optional side
burner.
4) Connect the corrugated gas line to the 90º Connection.
A
B
D
ii
i
CONNECTION CHART
Top View
A
Typical tank cabinet or tank enclosure location
B
Side View
C
iv
Top of Box
E
D
Back of Box
E
Corrugated Gas Line to Manifold
i
v
90° fitting
ii
C
1/2” (12.7 mm) Flared Gasket
iv
Cap (Optional Side Burner)
v
WWW.WEBER.COM®
Download from Www.Somanuals.com. All Manuals Search And Download.
GAS SUPPLY
30
VENTILATION
ƽ
WARNING:Ventillation holes must be provided in the
structure at the top and bottom to provide ventilation in the
event of a gas leak.
Ventilation holes can be located in a low visibility area and should be protected by
screening material to prevent rodents and insects from entering the structure. Air holes
will also help dry moisture.
Note: These drawings are only a reference.
•
Cross ventilation must be incorporated in the supporting structure. We recommend
a minimum of 100 square inches (254 square cm )of venting per side.
Vents should be on two sides of the structure.
•
•
•
•
•
The above drawings are for reference only.
Location of the vents should be from the center, outward.
Locate the vents at both the bottom of the structure and at the top of the structure.
The bottom vents should be as close to ground level as possible. Make sure the
vent area is not blocked by interior supports of the structure.
We recommend vents with screens.
•
•
•
Access doors to the structure are not considered vents.
Clean the vents periodically.
ƽ
DANGER: Failure to follow recommended minimum venting
instructions can cause gas to collect in the structure in the
event of a gas leak.This may result in a fire or an explosion
which can cause serious bodily injury or death, and damage
to property.
WWW.WEBER.COM®
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES
31
31
Download from Www.Somanuals.com. All Manuals Search And Download.
ƽ ATTENTION:This product has been safety tested and is only certified for use in a specific country. Refer to country designation
located on outer carton.
These parts may be gas carrying or gas burning components. Please contact Weber-Stephen Products Co., Customer Service Department for genuine Weber-Stephen
Products Co. replacement part(s) information.
ƽ WARNING: Do not attempt to make any repair to gas carrying, gas burning, igniter components or structural components
without contacting Weber-Stephen Products Co., Customer Service Department.Your actions, if you fail to follow this Product
Warning, may cause a fire, an explosion, or structural failure resulting in serious personal injury or death as well as damage to
property.
WEBER-STEPHEN PRODUCTS CO.
©2009 The following trademarks are registered in the name of Weber-Stephen Products Co., an Illinois corporation, located at 200 East Daniels Road, Palatine, Illinois 60067 U.S.A.
Australia; Smokey Joe, Weber, Kettle Silhouette , Genesis, Austria; Kettle Silhouette , Smokey Joe, Weber, Benelux; Kettle Silhouette , Smokey Joe, Weber, Compact Grill Configura-
tion, Botswana; Weber, Canada; Smokey Joe, Genesis, China; Kettle Silhouette , Denmark; Kettle Silhouette , Smokey Joe, Weber, Finland; Smokey Joe, France; Kettle Silhouette ,
Smokey Joe, Weber, One-Touch, Germany; Smokey Joe, Weber, One-Touch, Greece; Smokey Joe, Ireland; Kettle Silhouette , Smokey Joe, Italy; Smokey Joe, Weber, Japan; Smokey
Joe, Weber, Korea; Smokey Joe, Weber, New Zealand; Weber, Smokey Joe, Nigeria; Weber, Norway; Smokey Joe, Weber, Portugal; Weber, South Africa: Smokey Joe, Weber, Kettle
Configuration, Spain; Smokey Joe, Weber, Sweden; Kettle Silhouette , Smokey Joe, Switzerland; Kettle Silhouette , Smokey Joe, Weber, United Kingdom; Smokey Joe, Weber, Weber
One-Touch, U.S.A..; Kettle Configuration, Kettle Silhouette , Smokey Joe, Weber, One-Touch, Firespice, Go-Anywhere, U.S.A.;Kettle Configuration, Kettle Silhouette, Genesis, Flavorizer,
Crossover, Flamgo, Performer, Rapidfire, Tuck ‘N Carry, Jumbo Joe, Bar-B-Kettle, Master-Touch, Spirit, Grill Out, Summit, Platinum, 1-800-Grill-Out, Ranch, Matchless Flame, Zimbabwe;
Weber, Kettle Configuration, Kettle Silhouette .
Download from Www.Somanuals.com. All Manuals Search And Download.
|
Taylor Blender AC 1200 BL User Manual
Technicolor Thomson MP3 Player PDP2356K User Manual
Thule Automobile Accessories 91726 User Manual
Timex Watch 810 095009 NA User Manual
Toshiba Marine Radio C650 User Manual
TP Link Speaker TL R402M User Manual
Transition Networks Home Security System E TBT MC04 User Manual
Traulsen Refrigerator RDT132WUT HHS User Manual
Tripp Lite Welding System APINT Series User Manual
ViewSonic Car Video System VS15465 User Manual