QUICK START GUIDE
Wasp DuraLine
Industrial Scanner
WASP WLS 8400 ER/FZ SERIES
Dura
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICK START GUIDE
TROUBLESHOOTING
Scanner not working
Scanner not decoding bar code
No power to scanner
Check system power;
ensure power supply,
if required, is connected
Incorrect interface
cable used
Ensure that correct
Interface/power
cables are loose
Check for loose
Scanner not programmed Bar code unreadable
Distance between
scanner and bar
code incorrect
Move scanner
closer to or further
from bar code
for bar code type
Ensure bar code is not
defaced; try scanning
test bar code of same
bar code type
Ensure scanner is
programmed to read type
of bar code beingscanned
interface cable is used
cableconnections
Scanner decoding bar code, but data not transmitting to host
Scanned data incorrectly displayed on host
Scanner not programmed for
correct host interface
Interface cable is loose
Check for loose cable connections
Scanner not programmed for correct host interface
Check scanner host parameters or edit options
Check scanner host parameters
or edit options
SCANNER PROGRAMMING BAR CODES
Start Here if you have a keyboard wedge scanner
Start Here if you have a USB scanner
Reset Defaults
USB Host Types
Keyboard Wedge Host Types
Set Postamble
Erase All Rules
1
2
<Enter>
<Tab>
Enter
5
Save All Rules
Begin New Rules
Send All Data
4 Choose a Postamble
3
Tab
NOTE
If you do not need a Postamble scan
Erase All Rules only.
1
LED INDICATIONS
Off
Scanner is on and
ready to scan, or no
power to scanner
BEEPER INDICATIONS
Standard Use
Low/medium/high beep
Power up
Short high beep
Bar code decoded [if
decode beeper enabled]
4 long low beeps
Transmission error
detected; data is ignored
Green
Bar code is
Parameter Menu Scanning
successfully decoded
High/low/high/low beep High/low beep
Low/high beep
Successful parameter
setting
Correct programming
sequence performed
Incorrect programming
sequence or Cancel bar
code scanned
Red
Transmission error
©2005 Wasp Technologies. All rights reserved.
Wasp reserves the right to make changes to any product to improve reliability, function, or design. Wasp does not assume any product liability arising out of, or in connection with, the
application or use of any product, circuit, or application described herein. No license is granted, either expressly or by implication, estoppel, or otherwise under any patent right or patent,
covering or relating to any combination, system, apparatus, machine, material, method, or process in which Wasp products might be used. An implied license exists only for equipment,
circuits, and subsystems contained in Wasp products. Wasp and the Wasp logo are registered trademarks of Wasp Technologies. Other product names mentioned in this manual may be
trademarks or registered trademarks of their respective companies and are hereby acknowledged.
Download from Www.Somanuals.com. All Manuals Search And Download.
WASP DURALINE INDUSTRIAL SCANNER
LASER LABELS
PATENTS
This product is covered by one or more of the following U.S. and foreign Patents:
U.S. Patent No. 4,593,186; 4,603,262; 4,607,156; 4,652,750; 4,673,805;
4,736,095;4,758,717; 4,760,248; 4,806,742; 4,816,660; 4,845,350; 4,896,026;
4,897,532; 4,923,281; 4,933,538; 4,992,717; 5,015,833; 5,017,765; 5,021,641;
5,029,183; 5,047,617; 5,103,461; 5,113,445; 5,130,520; 5,140,144; 5,142,550;
5,149,950; 5,157,687; 5,168,148; 5,168,149; 5,180,904; 5,216,232; 5,229,591;
5,230,088; 5,235,167; 5,243,655; 5,247,162; 5,250,791; 5,250,792; 5,260,553;
5,262,627; 5,262,628; 5,266,787; 5,278,398; 5,280,162; 5,280,163; 5,280,164;
5,280,498; 5,304,786; 5,304,788; 5,306,900; 5,324,924; 5,337,361; 5,367,151;
5,373,148; 5,378,882; 5,396,053; 5,396,055; 5,399,846; 5,408,081; 5,410,139;
5,410,140; 5,412,198; 5,418,812; 5,420,411; 5,436,440; 5,444,231; 5,449,891;
5,449,893; 5,468,949; 5,471,042; 5,478,998; 5,479,000; 5,479,002; 5,479,441;
5,504,322; 5,519,577; 5,528,621; 5,532,469; 5,543,610; 5,545,889; 5,552,592;
5,557,093; 5,578,810; 5,581,070; 5,589,679; 5,589,680; 5,608,202; 5,612,531;
5,619,028; 5,627,359; 5,637,852; 5,664,229; 5,668,803; 5,675,139; 5,693,929;
5,698,835; 5,705,800; 5,714,746; 5,723,851; 5,734,152; 5,734,153; 5,742,043;
5,745,794; 5,754,587; 5,762,516; 5,763,863; 5,767,500; 5,789,728; 5,789,731;
5,808,287; 5,811,785; 5,811,787; 5,815,811; 5,821,519; 5,821,520; 5,823,812;
5,828,050; 5,848,064; 5,850,078; 5,861,615; 5,874,720; 5,875,415; 5,900,617;
5,902,989; 5,907,146; 5,912,450; 5,914,478; 5,917,173; 5,920,059; 5,923,025;
5,929,420; 5,945,658; 5,945,659; 5,946,194; 5,959,285; 6,002,918; 6,021,947;
6,029,894; 6,031,830; 6,036,098; 6,047,892; 6,050,491; 6,053,413; 6,056,200;
6,065,678; 6,067,297; 6,082,621; 6,084,528; 6,088,482; 6,092,725; 6,101,483;
6,102,293; 6,104,620; 6,114,712; 6,115,678; 6,119,944; 6,123,265; 6,131,814;
6,138,180; 6,142,379; 6,172,478; 6,176,428; 6,178,426; 6,186,400; 6,188,681;
6,209,788; 6,209,789; 6,216,951; 6,220,514; 6,243,447; 6,244,513; 6,247,647;
6,308,061; 6,250,551; 6,295,031; 6,308,061; 6,308,892; 6,321,990; 6,328,213;
6,330,244; 6,336,587; 6,340,114; 6,340,115; 6,340,119; 6,348,773; 6,380,949;
6,394,355; D305,885; D341,584; D344,501; D359,483; D362,453; D363,700;
D363,918; D370,478; D383,124;
In accordance with Clause 5, IEC 825 and EN60825, the following
information is provided to the user:
ENGLISH
CLASS 1 CLASS 1 LASER PRODUCT CLASE 1 PRODUCTO LASER DE LA
CLASS 2 LASER LIGHT CLASE 1
DO NOT STARE INTO BEAM CLASE 2 LUZ LASER
CLASS 2 LASER PRODUCT NO MIRE FIJAMENTE EL HAZ
SPANISH / ESPAÑOL
PRODUCTO LASER DE LA
CLASE 2
DUTCH / NEDERLANDS
KLASSE 1 KLASSE-1 LASERPRODUKT
KLASSE 2 LASERLICHT
GERMAN / DEUTCH
NIET IN STRAAL STAREN
KLASSE-2 LASERPRODUKT
KLASSE 1 LASERPRODUKT DER
KLASSE 1
KLASSE 2 LASERSTRAHLEN
NICHT DIREKT IN DEN
LASERSTRAHL SCHAUEN
LASERPRODUKT DER
KLASSE 2
FRENCH / FRANÇAIS
CLASSE 1 PRODUIT LASER DE CLASSE 1
CLASSE 2 LUMIERE LASER
NE PAS REGARDER LE
RAYON FIXEMENT
PRODUIT LASER DE CLASSE 2
RADIO FREQUENCY INTERFERENCE REQUIREMENTS
Note: This equipment has been tested and
found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC
Tested to comply
with FCC Standards
D391,250; D405,077; D406,581; D414,171; D414,172; D418,500; D419,548;
D423,468; D424,035;
D430,158; D430,159; D431,562; D436,104.
Invention No. 55,358; 62,539; 69,060; 69,187, NI-068564 (Taiwan); No.
1,601,796; 1,907,875; 1,955,269 (Japan); European Patent 367,299; 414,281;
367,300; 367,298; UK 2,072,832; France 81/03938; Italy 1,138,713
FOR HOME OR OFFICE USE
rules. These limits are designed to provide
reasonable protection against harmful inter-
ference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio communications.
However there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of the
following measures:
ERGONOMIC RECOMMENDATIONS
Caution: In order to avoid or minimize the potential risk of ergonomic injury
follow the recommendations below. Consult with your local Health & Safety
Manager to ensure that you are adhering to your company's safety programs to
prevent employee injury.
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected
• Consult the dealer or an experienced radio/TV technician for help.
• Reduce or eliminate repetitive motion
• Maintain a natural position
• Reduce or eliminate excessive force
• Keep objects that are used frequently within easy reach
• Perform tasks at correct heights
• Reduce or eliminate vibration
• Reduce or eliminate direct pressure
• Provide adjustable workstations
• Provide adequate clearance
• Provide a suitable working environment
• Improve work procedures.
Radio Frequency Interference Requirements – Canada
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
Marking and European Economic Area (EEA)
LASER DEVICES
Wasp products using lasers comply with US 21CFR1040.10, and
IEC825-1:1993, EN60825-1:1994+A11:1996. The laser classification
is marked on one of the labels on the product.
REGULATORY INFORMATION
All Wasp devices are designed to be compliant with rules and regulations in
locations they are sold and will be labeled as required.
Class 1 Laser devices are not considered to be hazardous when used for their
intended purpose. The following statement is required to comply with US and
international regulations:
Any changes or modifications to Wasp Technologies equipment, not expressly approved
by Wasp Technologies, could void the user's authority to operate the equipment.
Caution: Use of controls, adjustments or performance of procedures other
than those specified herein may result in hazardous laser light exposure.
Antenna’s, use only the supplied or an approved replacement antenna.
Unauthorized antennas, modifications, or attachments could cause damage and
may violate regulations.
Class 2 laser scanners use a low power, visible light diode. As with any very bright
light source, such as the sun, the user should avoid staring directly into the light
beam. Momentary exposure to a Class 2 laser is not known to be harmful.