Transition Networks Plumbing Product SISTF10xx 141 LRT User Manual |
Download from Www.Somanuals.com. All Manuals Search And Download.
Transition Networks
Table of Contents
Trademark, copyright, and product classification information......................................................................... iii
FCC warning.............................................................................................................................................. iii
CE Mark..................................................................................................................................................... iii
About this product and manual .......................................................................................................................iv
Industrial Switch.........................................................................................................................................iv
Term/usage................................................................................................................................................iv
About this manual ......................................................................................................................................iv
Manual structure ........................................................................................................................................iv
Cautions and warnings ....................................................................................................................................v
Cautions and warnings................................................................................................................................v
Cautions......................................................................................................................................................v
Warnings....................................................................................................................................................vi
SISTF10xx-141 Industrial Unmanaged Switch..........................................................................................................1
In this section..............................................................................................................................................1
Overview.....................................................................................................................................................2
Standard models.........................................................................................................................................3
Physical description.........................................................................................................................................5
Installation.................................................................................................................................................................7
In this section..............................................................................................................................................7
DIN rail mounting.............................................................................................................................................8
Wall mounting................................................................................................................................................10
Grounding the Industrial Switch.....................................................................................................................11
Industrial Switch grounding.......................................................................................................................11
Connecting power to the Industrial Switch.....................................................................................................12
Terminal-block wiring................................................................................................................................13
In this section............................................................................................................................................20
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
i
Download from Www.Somanuals.com. All Manuals Search And Download.
Transition Networks
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
AutoCrossTM..............................................................................................................................................21
Auto-Negotiation (IEEE 802.3u)................................................................................................................21
Pause (IEEE 802.3xy)..............................................................................................................................21
Section IV:...............................................................................................................................................................22
In this section............................................................................................................................................22
Copper (RJ-45) cable specifications..............................................................................................................23
Fiber cable and optic specifications...............................................................................................................24
Section V:................................................................................................................................................................25
In this section............................................................................................................................................25
Section VI:...............................................................................................................................................................27
In this section............................................................................................................................................27
Web-based training...................................................................................................................................28
Warranty........................................................................................................................................................29
Non-warranty repair costs.........................................................................................................................30
Repaired non-warranty products...............................................................................................................30
Compliance information.................................................................................................................................31
UL Listed; C-UL Listed (Canada).............................................................................................................31
Appendix A:.............................................................................................................................................................33
Notices......................................................................................................................................................34
ii
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Download from Www.Somanuals.com. All Manuals Search And Download.
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
Transition Networks
Trademark, copyright, and product classification information
Trademark
All trademarks and registered trademarks are the property of their respective owners.
Copyright
restrictions
© 2007 Transition Networks: All rights reserved. No part of this work may be reproduced or
used in any form or by any means—graphic, electronic, or mechanical—without written
permission from Transition Networks.
Printed in the U.S.A.
FCC warning
This equipment has been tested and found to comply with the limits for class A devices,
pursuant to part 15 of FCC rules. These limits are designed to provide reasonable
protection against harmful interference in a commercial installation. This equipment
generates, uses, and radiates radio frequency energy; therefore, if it is not installed and
used in accordance with the instructions in this document, could cause harmful
interference to radio communications. Operation of this equipment in a residential area
is likely to cause harmful interference; the user will be required to correct the interference
at the user’s own expense.
CE Mark
CE Marking (European Conformity): This is a Class A product. In a domestic
environment, this product could cause radio interference; as a result, the user may be
required to take adequate preventative measures.
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
Transition Networks
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
About this product and manual
Industrial Switch
The SISTF10xx-141-LR(T) Industrial Unmanaged Switch provides four 10/100Base-TX (RJ-
45) copper connections and a 100Base-FX fiber connection. These switches are hardened
devices designed to reliably operate in harsh environments such as those found on factory
floors, outdoor enclosures or other hazardous environments.
Term/usage
In this manual, the term “Industrial Switch” (first letter upper case) refers to the
SISTF10xx-141-LR(T) 10/100Base-TX to 100Base-FX Industrial Unmanaged Switch.
About this
manual
This manual provides instructions on how to install, configure, and operate the
SISTF10xx-141-LR(T) 10/100Base-TX to 100Base-FX Industrial Unmanaged Switch.
Manual structure
This manual has a beginning table of contents; also, at the beginning of each section there is
a table of contents. As you traverse the manual, note the side headings. These side
headings make it easier to find specific information. The manual sections are as follows:
Section
I
Description
Industrial Switch general description, ordering information, package
contents and physical features/description
Installation and operation of the Industrial Switch
Advanced features
Cable Specifications
Troubleshooting
II
III
IV
V
VI
Contacting Transition Networks, product warranty and product compliance
information
Presents product specifications, notices, and warnings
Appendix A
iv
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Download from Www.Somanuals.com. All Manuals Search And Download.
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
Transition Networks
Cautions and warnings
Cautions and
warnings
Make sure that you read and understand all content identified by these two symbols:
Cautions and warnings appear here and throughout this manual where appropriate. Failure to
read and understand the information identified by the “caution” and “warning” symbols could
result in poor equipment performance, damage to equipment, or injury to persons.
Cautions
Cautions indicate the possibility of damage to equipment.
CAUTION
Make sure that the Industrial Switch is mounted with proper space around it for ventilation
(heat dissipation). Failure to observe this caution could result in damage to the Industrial
Switch.
CAUTION
Please exercise caution when using power tools. Do not install this unit in damp or wet
locations, or in close proximity to very hot surfaces. Failure to observe this caution could
result in damage to the Industrial Switch and cables.
CAUTION
Only qualified persons should install the Industrial Switch. Failure to observe this caution
could result in poor performance or damage to the Industrial Switch.
CAUTION
Install the Industrial Switch in an environment where the temperature range will not
exceed the stated environmental specifications for the particular model being installed.
Failure to observe this caution could result in permanent damage to the Industrial Switch.
CAUTION
DO NOT install the Industrial Switch in areas where strong electromagnetic fields (EMF)
exist. Failure to observe this caution could result in poor Industrial Switch performance
and data corruption.
CAUTION
The Industrial Switch must be mounted to a well-grounded surface. Failure to observe
this caution could result in EMI problems.
CAUTION
When connecting DC power wires to the terminal-block plug, pay close attention to the
polarity markings shown near the terminal block of the Industrial Switch. Failure to
observe this caution could result in damage to the equipment.
CAUTION
This is a Class A product. In a residential environment, this product could cause radio
interference in which case the user may be required to take adequate corrective
measures.
Continued on next page
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
v
Download from Www.Somanuals.com. All Manuals Search And Download.
Transition Networks
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
Cautions and warnings, continued
Warnings
Warnings indicate the possibility of injury to persons.
WARNING
Be sure to disconnect power before installing and wiring the Industrial Switch. Failure to
observe this warning could result in an electrical shock.
WARNING
Fiber optics: Visible and invisible laser radiation when open: DO NOT stare into the
beam, or directly view the beam with optical instruments. Failure to observe this warning
could result in an eye injury or blindness.
WARNING
Use of controls, adjustments or the performance of procedures other than those
specified herein may result in hazardous radiation exposure.
vi
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Download from Www.Somanuals.com. All Manuals Search And Download.
Transition Networks
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
General description
Overview
The SISTF10xx-141 Industrial Unmanaged Switch can help eliminate EMI or RFI issues and
help to overcome distance limitations with copper-based cabling by providing a fiber interface
to transport data from copper-based industrial networking and communication devices over
fiber optic cabling.
Each Industrial Switch can connect to either 10Base-T or 100Base-TX copper ports and
provides a 100Base-FX fiber optic connection for links up to 20km. Multiple connector options
are offered as well as two distinct operating temperature ranges:
-
-
Standard: 0°C to +60°C (32°F to +140°F)
Extended: -40°C to +75°C (-40°F to +167°F)
Features
The SISTF10xx-141 Industrial Unmanaged Switch has the following features:
•
•
•
Auto-Negotiation
AutoCrossTM
Dual, redundant auto-sensing 12 to 48VDC inputs with reverse polarity protection
and over current protection
•
IEEE 802.3x flow control support
ꢀ
ꢀ
Flow control on full-duplex
Back pressure on half-duplex
•
•
•
•
•
•
512KB Embedded memory
1K MAC address table
DIN-Rail mounting bracket (installed)
Wall mount bracket included
DIP-switch to set the fiber port mode of operation – full or half-duplex
Barrel connector interface cable included for use with external AC/DC power supply
(order separately)
•
•
IP31 protection metal enclosure
Lifetime Warranty
2
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Download from Www.Somanuals.com. All Manuals Search And Download.
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
Transition Networks
SISTF10xx-141 Industrial Unmanaged Switch part numbers
Standard models
The part numbers shown in Tables 1 and 2 perform as described in this manual.
Table 1: Industrial Unmanaged Switch Part Numbers
Standard Operating Temperature (0°C to +60°C)
Part Number
SISTF1011-141-LR
Ports 1-4: 10/100Base-TX Port 5: 100Base-FX
RJ-45
ST, 1300 nm multimode
2 km (1.2 miles)
100 m (328ft)
RJ-45
100 m (328ft)
RJ-45
100 m (328ft)
SISTF1013-141-LR
SISTF1014-141-LR
SC, 1300 nm multimode
2 km (1.2 miles)
SC, 1310 nm single mode
20 km (12.4 miles)
Table 2: Industrial Unmanaged Switch Part Numbers
Extended Operating Temperature (-40°C to +75°C)
Part Number
SISTF1011-141-LRT
Ports 1-4: 10/100Base-TX Port 5: 100Base-FX
RJ-45
ST, 1300 nm multimode
2 km (1.2 miles)
100 m (328ft)
RJ-45
100 m (328ft)
RJ-45
100 m (328ft)
SISTF1013-141-LRT
SISTF1014-141-LRT
SC, 1300 nm multimode
2 km (1.2 miles)
SC, 1310 nm single mode
20 km (12.4 miles)
Note: The distances for ports 1 and 2 listed in Tables 1 and 2 are typical maximum
distances; the physical characteristics of the network will affect the actual distances.
Table 3: Optional Accessories (sold separately)
Part Number
Description
SPS-UA12DHT-xx
External power supply includes:
(1) AC/DC power supply, 100-240VAC input, 50-60Hz,
12VDC, 1.5A ouput, -25°C to +70°C operating temp.
(1) Regional specific power cord
(1) Barrel connector interface cable
Note: Replace the xx in the part number above with one of the following identifiers to match
the region where the Industrial Switch will be installed:
NA = North America
UK = United Kingdom
JP = Japan
OZ = Australia/New Zealand
SA = South Africa
EU = Europe
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Transition Networks
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
Package contents
Package
contents
Quantity
Description
1
1
1
6
1
1
10/100BaseTX to 100BaseFX Industrial Unmanaged Switch
DIN-Rail mounting bracket (installed)
One wall mount plate
Screws (for attaching wall-mount bracket)
Installation manual CD
Barrel connector interface cable
-
For external AC/DC power supply (sold separately)
Compare the package contents of your industrial Switch with the standard checklist above. If
any item is damaged or missing, please contact Transition Networks Technical Support.
4
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Download from Www.Somanuals.com. All Manuals Search And Download.
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
Transition Networks
Physical description
Physical
dimensions
Width: 2.1” [54mm]
Height: 5.3” [135mm]
Depth: 4.1” [105mm]
Front panel
The front panel of the Industrial Switch is shown in Figure 1 with corresponding descriptions
listed below:
Secondary power input 2 LED
Primary power input 1 LED
Power LED
Link / Activity Fiber Port 5 LED
Full Duplex / Collision Fiber Port 5 LED
100Base-FX
fiber port
Full-duplex / Half-duplex Fiber Port 5
DIP switch
Link / Activity Copper Port 1-4 LED
Full Duplex / Collision Copper Port 1-4 LED
10/100Base-TX
UTP ports (RJ-45)
Terminal block - power inputs
Figure 1: SISTF10xx-141-LR(T) Industrial Switch (Front View)
Continued on next page
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Transition Networks
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
Physical description, continued
Bottom panel
The bottom view of the Industrial Switch is shown in Figure 2 with corresponding descriptions
listed below:
Grounding Screw
6-position terminal block
Primary power input terminals (2)
Secondary power input terminals (2)
Figure 2: SISTF10xx-141-LR(T) Industrial Switch (Bottom View)
Back panel
The back view of the Industrial Switch is shown in Figure 3 with corresponding descriptions
listed below:
DIN Rail Clip
(installed)
Metal spring
Screws (3)
Figure 3: SISTF10xx-141-LR(T) Industrial Switch (Back View)
6
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Download from Www.Somanuals.com. All Manuals Search And Download.
Section II
Installation
In this section
These are the topics:
Topic
See Page
DIN rail mounting
Wall mounting
Grounding the Industrial Switch
Connecting power to the Industrial Switch
Connecting fiber cable
Connecting copper cable
DIP switches
Light Emitting Diodes (LEDs)
8
10
11
12
16
17
18
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Transition Networks
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
DIN rail mounting
DIN rail clip
The Industrial Switch includes an aluminum DIN Rail Clip attached to the rear panel. Verify
the clip is attached and oriented as pictured in Figure 4 below.
DIN Rail Clip
(installed)
Metal spring
Screws (3)
Figure 4: Mounted DIN Rail Clip
DIN rail mounting
considerations
Consider the following before mounting the DIN rail to a surface and attaching the Industrial
Switch:
•
The surface must support at least 635g (1.4 lbs) for the Industrial Switch.
•
Do not place heavy objects on the Industrial Switch.
CAUTION
Mount the Industrial Switch with proper spacing around it for ventilation (heat
dissipation). Failure to observe this caution could result in damage to the Industrial
Switch.
CAUTION
Please exercise caution when using power tools. Do not install this unit in damp or wet
locations, or in close proximity to very hot surfaces. Failure to observe this caution could
result in damage to the Industrial Switch and cables.
Continued on next page
8
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Download from Www.Somanuals.com. All Manuals Search And Download.
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
Transition Networks
DIN rail mounting, continued
DIN rail mounting
To mount the Industrial Switch to the DIN rail, see Figure 5 and do the following:
Step
1.
Action
Align and then position DIN-Rail-clip spring to the top of the DIN rail as shown in
Figure 5, step (a).
2.
Press DOWN on the Industrial Switch and then IN to snap it into place on the DIN
Rail. See Figure 5, step (b).
Figure 5: Industrial Switch Mounting to DIN Rail
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Transition Networks
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
Wall mounting
Wall mount
bracket
The Industrial Switch includes a wall mount bracket and screws in the contents of the shipping
package. The wall mount bracket can be attached to the rear panel of the Industrial Switch to
enable mounting to a vertical surface such as the wall of an enclosure. Locate the bracket (1)
and screws (6) and follow the steps below to install the bracket on the Industrial Switch.
Wall mount
bracket install
To install the wall mount bracket to the Industrial Switch, see Figure 6 and do the following:
Step
1.
2.
Action
Remove existing screws (3) and DIN-Rail bracket from rear of Industrial Switch.
Locate wall mount bracket and screws (6) from Industrial Switch packaging.
Place bracket in correct orientation as shown and insert and tighten screws to
secure bracket to rear of Industrial Switch.
3.
4.
Mount assembled device to a wall per locally accepted practices for anchoring
and securing. (Wall mount screws not included.)
Screw bracket onto rear
of Industrial Switch
Locate wall mount
brackets and screws
3
2
Remove screws and
1
DIN rail bracket
Figure 6: Installing wall mount bracket to Industrial Switch
10
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Download from Www.Somanuals.com. All Manuals Search And Download.
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
Transition Networks
Grounding the Industrial Switch
CAUTION
Be sure to disconnect the Industrial Switch from the DC power source before installing
and wiring the device.
Wiring
considerations
The following wiring considerations are recommended:
•
•
Signal lines must not be directly connector to outdoor wiring.
Use separate paths or conduits to route wiring for power and device data cables. To avoid
interference, wires with different signal characteristics route separately. If power wiring and
device data cables must cross make sure that the wires are perpendicular at the
intersection point.
•
•
Use the type of signal transmitted through a wire to determine which wires should be kept
separate. The rule of thumb is wiring that shares similar electrical characteristics can be
bundled together.
Keep input and output wiring separated.
CAUTION
The Industrial Switch is intended to be grounded to a well-grounded mounting surface
such as a metal plate. Install the grounding wire prior to connecting any other device to
the Industrial Switch.
Industrial Switch
grounding
Grounding the Industrial Switch helps limit the effects of noise due to electromagnetic
interference (EMI) via proper grounding. Always run the ground connection from the ground
screw to a grounding surface before connecting the Industrial Switch to a DC power source.
See Figure 7.
Figure 7: Industrial Switch Ground Screw (Bottom Panel)
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Transition Networks
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
Connecting power to the Industrial Switch
Redundant
power inputs
The Industrial Switch has dual (redundant) power inputs capable of auto-sensing the input
voltage, while providing over current protection and reverse polarity protection.
The dual power inputs can be connected simultaneously to live DC power sources. See Figure
8. If one power source fails, the other live source acts as a backup, and automatically supplies
the Industrial Switch with power.
Power Input 2
Power Input 1
Figure 8: Redundant Power Connections
IMPORTANT
•
Power is supplied through an external 12-48 VDC power source. Check the Technical
Specification section for details about the DC power input voltage.
•
The Industrial Switch does not include a power switch; therefore, plugging a wired and
active terminal-block plug into its terminal block will immediately power ON the unit.
CAUTION
Before connecting the Industrial Switch to a DC power source, ensure the power source
is stable.
CAUTION
This device is intended to be supplied by a listed power source marked LPS or Limited
Power Source, provided with a connector for field wiring terminal.
CAUTION
This device is designed for operation with a safety extra-low voltage (SELV) in
compliance with IEC950 / EN60950 / VDE0805 and in compliance with the low voltage
directive 73/23/EEC and 93/68/EEC.
Continued on next page
12
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Download from Www.Somanuals.com. All Manuals Search And Download.
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
Transition Networks
Connecting power to the Industrial Switch, continued
Note: The terminal block can accept 12 – 24 AWG wire for power and alarm relay inputs.
Terminal-block
wiring
To wire the 6-position terminal block for redundant power, do the following:
Note: The 6-position terminal-block plug is constructed (keyed) to mate with the Industrial
Switch terminal block. When wiring the plug for power, use the polarity markings next
to the terminal block and on top of the plug to ensure proper connection.
Step
1.
2.
Action
Turn the external power source OFF.
Strip the power wires as required.
3.
Insert one stripped power wire into the terminal block plug. Observe polarity.
See Figure 9.
4.
5.
Secure the wire using a flathead screwdriver by tightening the contact screw.
See Figure 9.
Repeat Steps 3 and 4 until all wires are installed and secured.
Figure 9: 6-Position Terminal-Block (Primary/Redundant Power Wiring)
Continued on next page
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Transition Networks
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
Connecting power to the Industrial Switch, continued
Terminal-block wiring (continued)
Step
Action
6.
Insert the terminal block plug into the Industrial Switch’s terminal block, as shown
in Figure 10.
Figure 10: Wired Terminal Block Plug Inserted Into Industrial Switch
7.
8.
Make sure that the DC power source is stable and clean.
Turn ON the power source and the PWR LED should turn ON along with PWR 1
LED and/or PWR 2 LED, depending on whether one or both power supplies are
connected and turned ON.
14
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Download from Www.Somanuals.com. All Manuals Search And Download.
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
Transition Networks
Connecting power to the Industrial Switch, continued
Barrel connector
interface cable
A barrel connector interface cable is included with the Industrial Switch and can be used to
convert the barrel connector output of an external AC/DC power supply over to a wire interface
that can then be inserted into the terminal block following the instructions and figure 9, both
located on page 13 of this manual.
Note: An external AC/DC power supply is not included with the Industrial Switch. Transition
Networks offers an accessory power supply that can be purchased separately, if
required. Please see optional accessories in the general information section of this
manual for ordering information.
CAUTION
The operating temperature of the Industrial Switch, when used in conjunction with an
AC/DC power supply will be limited to the lesser operating temperature range of either
device.
For example: SISTF10xx-141-LRT (-40ºC to +75ºC operating temp) used
with SPS-UA12DHT-xx (-25ºC to +70ºC operating temp)
Operating temp for combination is -25ºC to +70ºC
Step
1.
Action
Locate the barrel interface cable included in the Industrial Switch packaging.
Strip the power wires as required.
2.
3.
Insert one stripped power wire into the terminal block plug, Observe polarity. See
Figure 9 on page 13.
4.
Secure the wire using a flathead screwdriver by tightening the contact screw.
See Figure 9 on page 13.
5.
6.
Repeat Steps 3 and 4 until all wires are installed and secured.
Locate an external AC/DC power supply with barrel connector interface and
make sure the power supply is not plugged into any power source.
Insert barrel connector into the receptacle on the interface cable. See Figure 11.
7.
External AC/DC
power supply with
barrel connector
Barrel Connector
Interface Cable
Figure 11: Barrel Connector Interface Cable with external power supply
Step
8.
Action
Plug external AC/DC power supply into an external power source.
Turn ON or plug in the external power supply and the PWR LED should turn ON
along with PWR 1 LED and/or PWR 2 LED, depending on whether one or both
power supplies are connected and turned ON.
9.
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Transition Networks
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
Connecting fiber cables
Fiber cable
installation
When connecting fiber cables to the 100BASE-FX port on the Industrial Switch, make sure the
correct type is used: ST or SC.
To install the fiber cables, do the following:
Step
1.
Action
Remove and keep the fiber-port protective dust cover(s).
Note: When not connected to a fiber cable, keep the protective cover(s) on the optical ports
to protect the optics and keep dust and debris from entering the optical interface.
2.
Check that the fiber connectors on the fiber-optic cabling are clean. If necessary,
clean the fiber connectors using locally accepted cleaning procedures.
Note: Dirty fiber connectors on fiber optic cables will impair light transmission quality
through the cable and lead to degraded performance on the port.
3.
Connect the fiber cable as shown in Figure 12.
Figure 12: Fiber Cable Connections
4.
Check the corresponding fiber port LED on the Industrial Switch to verify the
connection—LNK/ACT LED should be lit.
Warning
•
Visible and invisible laser radiation when open: DO NOT stare into the beam, or
directly view the beam with optical instruments. Failure to observe this warning could
result in an eye injury.
• Use of controls, adjustments or the performance of procedures other than those
specified herein may result in hazardous radiation exposure.
16
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Download from Www.Somanuals.com. All Manuals Search And Download.
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
Transition Networks
Connecting copper cables
Copper cable
installation
To connect the copper cable to the Industrial Switch and other equipment, do the following:
Step
1.
Action
Locate or build 10Base-T or 100Base-TX copper cables with male, RJ-45
connectors installed at both ends.
2.
3.
4.
Connect the RJ-45 connector at one end of the cable to the RJ-45 port on
the Industrial Switch. See Figure 13 below.
Connect the RJ-45 connector at the other end of the cable to the RJ-45
port on the other device (switch, workstation, PLC, etc.).
Check the copper port LED on the Industrial Switch to verify the connection—
LNK/ACT LED should be lit.
Figure 13: Copper Cable Installation
Copper cable
configuration
Either a straight-through or cross-over cable may be used. See Figure 14.
Figure 14: Straight-Through and Crossover Cables
Note: The AutoCrossTM feature determines the characteristics of the cable connection and
automatically configures the unit to link up, regardless of the cable configuration,
allowing either straight-through (MDI) or crossover (MDI-X) cables to be used.
(Requires no operator intervention.). See Advanced Features section for more
information.
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Transition Networks
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
DIP Switches
DIP switch
position
descriptions
The Industrial Switch features one DIP switch on the front panel used to configure the fiber
port for use in a particular network setting. Figure 15 shows the DIP switch and a chart that
explains each setting.
ON
No Description
1
Default
OFF
Half-duplex / Full-duplex Fiber Port 5
(Half-duplex ON, Full-duplex OFF)
Figure 15: Dip Switch Setting and Explanation
CAUTION
DIP switch changes will not become active until the Industrial Switch is power cycled
(turned OFF then ON).
18
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Download from Www.Somanuals.com. All Manuals Search And Download.
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
Transition Networks
Light Emitting Diodes (LEDs)
LEDs
The Industrial Switch has LED indicators located on its front panel. The LEDs present at-a-
glance network status, and provide real-time connectivity information. Figure 16 shows the
LEDs and a chart that explains the function of each.
LED
Description
PWR
Green = input power present on either
of the power inputs
PWR1
PWR2
Green = input power present on PWR1
input
Green = input power present on PWR2
input
LNK/ACT
Green = fiber link
Green (blinking) = fiber port is receiving
link pulses or data from a
100Base-FX compliant port
(Fiber port)
FDX/COL
Orange = Full duplex
(Fiber port 5)
Off = Half duplex or no device attached
Orange (blinking) = Collisions occurring
LNK/ACT
Green = UTP link
Green (blinking) = UTP port is receiving
link pulses or data from a
10/100Base-TX compliant port
(UTP ports 1-4)
Off = No device attached
Orange = Full duplex
FDX
(UTP ports 1-4) Off = Half duplex or no device attached
Orange (blinking) = Collisions occurring
Figure 16: LEDs and Description Chart
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
19
Download from Www.Somanuals.com. All Manuals Search And Download.
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
Transition Networks
Advanced Features
AutoCrossTM
AutoCrossTM automatically detects and configures the twisted pair port on the converter to the
correct MDI or MDI-X configuration allowing either straight-through (MDI) or crossover (MDI-X)
cables to be used – see figure 17. No user intervention is required.
* Eliminates an entire category of troubleshooting
* No need to identify cable type; straight-through or crossover
* No user intervention required to determine correct button / switch settings
Figure 17: Straight-Through and Crossover Cables
Auto-Negotiation
(IEEE 802.3u)
Auto-Negotiation allows devices to perform automatic configuration to achieve the best
possible mode of operation over a link. The Industrial Switch will broadcast its speed
(10Mbps, 100Mbps) and duplex (half/full) capabilities to other devices and negotiate the best
mode of operation between the two devices.
* No user intervention required to determine best mode of operation
* Optimal link established automatically
* Quick and easy installation
Note: If the Industrial Switch is connected to a non-negotiating device over the copper link,
it will default to 10Mb/s speed, half duplex mode.
Pause
(IEEE 802.3xy)
PAUSE signaling is an IEEE feature that is used to temporarily suspend data transmission
between two devices in the event that one of the devices becomes overwhelmed. In the event
that a device needs some time to clear network congestion, it will send out a PAUSE signal to
the other end device, which will then wait a pre-determined amount of time before re-
transmitting the data. Transition's converters will pass PAUSE signaling unhindered; ensuring
that the message is delivered to the end device.
* PAUSE enabled devices allowed to work properly
* Prevents loss of valuable data transmission
* Reduces bottlenecks and allows for efficient use of network devices
Note: PAUSE signaling is not standardized over fiber media. Transition's Industrial Switchs
will communicate this signaling over fiber between the converters to pass this
signaling on to the other end device.
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Transition Networks
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
Section IV:
Cable Specifications
Introduction
This section provides copper and fiber cable specifications.
These are the topics:
In this section
Topic
UTP cable specifications
Fiber cable and optic specifications
See Page
23
24
22
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Download from Www.Somanuals.com. All Manuals Search And Download.
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
Transition Networks
Copper (RJ-45) cable specifications
Copper cabling
Shielded twisted-pair (STP) or unshielded twisted-pair (UTP) cabling may be used and can be
configured as either Straight-through or crossover – see figure 18.
Figure 18: Straight-Through and Crossover Cables
Note: The AutoCrossTM feature determines the characteristics of the cable connection and
automatically configures the unit to link up, regardless of the cable configuration,
allowing either straight-through (MDI) or crossover (MDI-X) cables to be used.
(Requires no operator intervention.). See Advanced Features section for more
information.
Copper cable
specifications
Wire category:
Attenuation:
Category 5 (minimum)
22.0 dB /100m @ 100 MHz
24 to 22 AWG
Gauge:
Maximum cable distance:
100 meters (328 ft)
RJ-45 pinouts
Figure 19 shows the RJ-45 connector pin assignment chart.
No
1
2
MDI Signal Name
Receive Data + (RD+)
Receive Data - (RD-)
Transmit Data + (TD+)
Transmit Data - (TD-)
MDI-X Signal Name
Transmit Data + (TD+)
Transmit Data - (TD-)
Receive Data + (RD+)
Receive Data - (RD-)
3
6
Figure 19: RJ-45 Connector Pin Assignment Chart
Note: The Industrial Switch is configured as a MDI-X device.
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Transition Networks
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
Fiber cable and optic specifications
Fiber cable
characteristics
Cable physical characteristics must meet or exceed IEEE 802.3™ specifications.
Parameter
Specification
Bit Error Rate:
<10-9
9 µm
Single mode fiber:
Multimode fiber:
Multimode fiber:
62.5/125 µm
100/140, 85/140, 50/125 µm
Fiber optic
specifications
The following shows the fiber optic specification:
Fiber Cable
Specifications
SISTF1011-141-LR(T)
1300 nm multimode
min: -20.0 dBm max: -14.0 dBm
min: -31.0 dBm max: 0.0 dBm
11.0dB
Fiber-optic transmitter power:
Fiber-optic receiver sensitivity:
Link budget:
SISTF1013-141-LR(T)
1300 nm multimode
min: -20.0 dBm max: -14.0 dBm
min: -30.0 dBm max: 0.0 dBm
11.0dB
Fiber-optic transmitter power:
Fiber-optic receiver sensitivity:
Link budget:
1310 nm single mode
min: -15.0 dBm max: -8.0 dBm
min: -34.0 dBm max: 0.0 dBm
19.0 dB
SISTF1014-141-LR(T)
Fiber-optic transmitter power:
Fiber-optic receiver sensitivity:
Link budget:
Note: The fiber optic transmitters on this device meet Class I Laser safety requirements per
IEC-825/CDRH standards and comply with 21CFR1040.10 and 21CFR1040.11.
24
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Download from Www.Somanuals.com. All Manuals Search And Download.
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
Transition Networks
Section V:
Troubleshooting
Introduction
This section provides basic troubleshooting information for the Industrial Switch via a problem
and corrective action table. The problems are stated in the problem column and the action(s)
to take for the problem is stated in the corrective action column. If the corrective measures
listed do not correct the problem, contact our 24-Hour Technical Support department at 1-800-
260-1312, International: 00-1-952-941-7600.
In this section
These are the topics:
Topic
Troubleshooting problem and corrective action table
See Page
26
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Transition Networks
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
Troubleshooting problem and corrective action table
Problem
Industrial Switch does not
power up
Potential Cause
Potential Solution
•
Wire and insert the terminal-block plug
into the Industrial Switch’s terminal
block – See pages 12-16
• Is the wired terminal-block plug fully
inserted into the Industrial Switch?
•
•
Check that DC power is at the
recommended levels.
• Is the power LED lit?
Contact Technical Support.
US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600
No link or activity on the
UTP port
•
•
Check that the power is turned ON.
• Is the power LED lit?
Verify that the cable at both ends is
properly inserted into the UTP port
• Is the UTP cable properly installed
at both ends?
•
Contact Technical Support.
US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600
No link or activity on the
Fiber port
•
•
Check that the power is turned ON.
• Is the power LED lit?
Verify that the cable at both ends is
properly inserted into the fiber port
• Is the Fiber cable properly installed
at both ends?
•
Contact Technical Support.
US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600
26
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Download from Www.Somanuals.com. All Manuals Search And Download.
Section VI:
Contact Us, Warranty, &
Compliance Information
Introduction
This section explains how to contact Transition Networks via Phone, fax, email, and direct
mail. It also explains:
• What the warranty covers
• Who to contact to return product
• How and where to return the product
• Industry standards compliance
In this section
These are the topics:
Topic
See Page
Contact us
Warranty
Compliance information
28
29
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Transition Networks
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
Contact us
Technical
support
Technical Support is available 24 hours a day.
United States:
International:
1-800-260-1312
00-1-952-941-7600
Live Web chat
Chat live via the Web with a Transition Networks Technical Support Specialist.
Web-based
training
Transition Networks provides 8-10 seminars per month via live web-based training.
E-Mail
Ask a question anytime by sending an e-mail message to our technical support staff at:
Address
Transition Networks
6475 City West Parkway
Minneapolis, MN 55344, U.S.A.
Telephone:
952-941-7600
800-526-9267
952-941-2322
Toll free U.S.A & Canada:
Fax:
28
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Download from Www.Somanuals.com. All Manuals Search And Download.
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
Transition Networks
Warranty
Limited lifetime
warranty
Effective for products shipped May 1, 1999 and after, every Transition Networks’ labeled
product will be free from defects in material and workmanship for its lifetime. This warranty
covers the original user only and is not transferable.
What the
warranty does
not cover
This warranty does not cover damage from accident, acts of God, neglect, contamination,
misuse or abnormal conditions of operation or handling, including over-voltage failures caused
by use outside the product’s specified rating, or normal wear and tear of mechanical
components. If the user is unsure of the proper means of installing or using the equipment,
contact Transition Networks’ free technical support services.
Warranty Service
Transition Networks will at its option:
• Repair the defective product to functional specification at no charge
• Replace the product with an equivalent functional product
• Refund the purchase price of a defective product
Who to contact
for returns
To return a defective product for warranty coverage, contact Transition Networks’ technical
support department for a return authorization number (RAN). Transition’s technical support
department can be reached through any of the following means:
Technical Support is available 24 hours a day:
• Tel: 800-260-1312 x 200 or 952-941-7600 x 200
• Fax: 952-941-2322
• Email: [email protected]
• Live web chat: Transition Now
• Voicemail: 800-260-1312 x 579 or 952-941-7600 x 579
• All messages will be answered within one hour
How and where
to send the
returns
Send the defective product postage and insurance prepaid to the following address:
CSI Material Management Center
c/o Transition Networks
6103 Blue Circle Drive
Minnetonka, MN 55343 U.S.A.
Attn: RETURNS DEPT: Credit Return Authorization (CRA)# or Return Material Authorization
(RMA) # ___________
Failure to protect the product during shipping may void this warranty. The return authorization
number must be written on the outside of the carton to ensure its acceptance. We cannot
accept delivery of any equipment sent to us without a CRA or RMA number.
Continued on next page
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Transition Networks
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
Warranty, continued
Customer pays
non-compliant
return costs
The customer must pay the non-compliant product(s) return transportation cost to Transition
Networks for evaluation of said product(s) for repair or replacement. Transition Networks will
pay for shipping the repaired or replaced in-warranty product(s) back to the customer (any and
all customs charges, tariffs, or/and taxes are the customer’s responsibility).
Non-warranty
repair costs
Before making any non-warranty repair, Transition Networks requires a $200 charge, plus
actual shipping costs to and from the customer. If the repair is greater than $200, an estimate
is issued to the customer for authorization of repair. If no authorization is obtained, or the
product is deemed not repairable, Transition Networks will retain the $200 service charge and
return the product to the customer not repaired.
Repaired non-
warranty
products
Non-warranted products repaired by Transition Networks for a fee will carry a 180-day limited
warranty. All warranty claims are subject to the restrictions and conventions set forth by this
document.
Transition Networks reserves the right to charge for all testing and shipping incurred, if after
testing, a return is classified as “No Problem Found.”
This warranty is
your only remedy
This warranty is your only remedy. No other warranties, such as fitness for a particular
purpose, are expressed or implied. Transition Networks is not liable for any special, indirect,
incidental or consequential damages or losses, including loss of data, arising from any cause
or theory. Authorized resellers are not authorized to extend any different warranty on
Transition Networks’ behalf.
30
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Download from Www.Somanuals.com. All Manuals Search And Download.
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
Transition Networks
Compliance information
Compliances
CISPR22/EN5022 Class A + EN55024; EN60950 Class A; FCC Class A; CE Mark
UL Listed;
C-UL Listed
(Canada)
The following part numbers are UL Listed: SISTF1011-141-LR, SISTF1011-141-LRT,
SISTF1013-141-LR, SISTF1013-141-LRT, SISTF1014-141-LR, SISTF1014-141-LRT.
FCC Regulations
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is
likely to cause harmful interference, in which case the user will be required to correct the
interference at the user’s own expense.
Canadian
Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus
set out on the radio interference regulations of the Canadian Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites
applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le
brouillage radioélectrique édicté par le ministère des Communications du Canada.
European
Regulations
CUATION:
This is a Class A product. In a domestic environment, this product could cause radio
interference in which case the user may be required to take adequate corrective measures.
Achtung !
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb
dieses Gerätes Rundfunkstörungen auftreten. In diesem Fäll ist der Benutzer für
Gegenmaßnahmen verantwortlich.
Attention !
Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer
des interférences radioélectriques, il appartiendra alors à l'utilsateur de prende les measures
spécifiques appropriées.
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Transition Networks
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
European
Regulations,
(continued)
In accordance with European Union Directive 2002/96/EC of the European Parliament and of
the Council of 27 January 2003, Transition Networks will accept post usage returns
of this product for proper disposal. The contact information for this activity can be
found in the ‘Contact Us’ portion of this document.
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE
PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in
damage to the public telephone network.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-
Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der
Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über
Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer
Konformität.
32
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A:
Technical Specifications
SISTF10xx-141-LR(T) specifications, notices, and warnings
Parameter
Standards
Description
IEEE 802.3TM, 802.3uTM, 802.3xTM
Regulatory Compliance for Emissions CISPR/EN55022 Class A; FCC Class A; CE Mark
Safety Compliance
EMI Compliance
UL 60950; cUL; CSA C22.2 no 60950
EN61000-4-2; EN61000-4-3; EN61000-4-4;
EN61000-4-5; EN61000-4-6
IEC60068-2-32 (Free fall)
Environmental Compliance
IEC60068-2-27 (Shock)
IEC60068-2-6 (Vibration)
Ports
(1) fiber port single mode/multi-mode
(4) RJ-45 port
Fiber Optic Specifications
1300 nm Multimode
TX power: min: -20.0 dBm max: -14.0 dBm
RX power: min: -31.0 dBm max: 0.0 dBm
Link budget: 11.0dB
1310 nm Single mode
TX power: min: -15.0 dBm max: -8.0 dBm
RX power: min: -32.0 dBm max: 0.0 dBm
Link budget: 19.0dB
Max Distance
Fiber (multimode): up to 2km (1.2 miles)
Fiber (single mode): up to 20km (12.4 miles)
Copper: up to 100 meters (328 ft.)
Fiber: 100 Mb/s
Max Data Rate
Copper: 10Mb/s or 100Mb/s
TxD, RxD, CTS, RTS, DTR, DSR, RI, DCD, GND
1K MAC address table
Signals
MAC Addresses
Memory Buffer
Transfer Rate
Packet Throughput
Backplane
512KB
14,880 pps [10Mb] or 148,800 pps [100Mb]
0.74Mpps @64bytes (4TX + 100FX)
1.0 Gbps
Power Consumption
Ingress Protection
MTBF
3.3 watts
IP31
380,973 hours (MIL-HDBK-217F)
12 to 48 VDC, 0.2A-0.7A; dual, redundant auto-
sensing inputs with reverse polarity and overload
current protection
Input Power
Width: 2.1" [54 mm]
Depth: 4.1" [105 mm]
Dimensions
Height: 5.3" [135 mm]
0.64 kg (1.4 lbs)
Weight
Shipping weight
Standard Operating Temperature
(-LR models only)
0.90 kg (2 lbs)
0ºC to +60ºC (32 ºF to 140ºF)
Extended Operating Temperature
(-LRT models only)
-40ºC to +75ºC (-40 ºF to 167ºF)
Storage Temperature
Operating Humidity
Warranty
-40ºC to +85ºC (-40 ºF to 185ºF)
5% to 90% (non-condensing)
Lifetime
Download from Www.Somanuals.com. All Manuals Search And Download.
Transition Networks
SISTF10xx-141-LR(T) Industrial Unmanaged Switch
SISTF10xx-141-LR(T) specifications, notices, and warnings, continued
Notices
•
The information in this user’s guide is subject to change. For the most up-to-date
information on the SISTF10xx-141-LR(T) Industrial Unmanaged Switch, please refer to the
•
•
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J
applicable at the date of manufacture.
IMPORTANT Copper based media ports: e.g., Twisted Pair (TP) Ethernet, USB, RS-232,
RS422, RS485, DS1, DS3, Video Coax, etc., are intended to be connected to intra-building
(inside plant) link segments that are not subject to lightening transients or power faults.
Copper based media ports: e.g., Twisted Pair (TP) Ethernet, USB, RS-232, RS-422, RS-
485, DS1, DS3, Video Coax, etc., are NOT to be connected to inter-building (outside plant)
link segments that are subject to lightening transients or power faults. Failure to observe
this caution could result in damage to equipment.
Warnings
WARNING: Visible and invisible laser radiation when open: Do not stare into the beam
or view the beam directly with optical instruments. Failure to observe this warning could
result in an eye injury or blindness.
WARNING: Use of controls, adjustments or the performance of procedures other than
those specified herein may result in hazardous radiation exposure.
34
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600