The wireless sensor system is comprised of a programmable, weather-resistant receiver module
and a sensor module with built-in transmitter. The receiver installs next to the irrigation controller
and connects to the controller’s 24 Vac power source and sensor input terminals (if equipped)
or splices directly into the irrigation valve common wire. The sensor module is installed within
range of the receiver in a location that best represents the landscape’s sun/shade exposure and
can provide reliable communication from the sensor to the receiver.
Once activated by preset rain or low temperature levels (rain/freeze model only), the sensor
communicates to the receiver via ultra high-frequency radio signal. The receiver responds by
placing the controller’s automatic watering schedule on hold or by simply opening the valve
common circuit to prevent sprinkler operation. When watering is once again needed, the sensor
system automatically resets, allowing automatic irrigation to resume.
More than just an accurate rain switch, the wireless sensor system actually adapts to your
landscape with the simple, yet sophisticated Water Conservation feature. Just choose the
conservation level that corresponds to your landscape soil type and the sensor location.
A dry-out period, adjusted for actual rainfall duration, is automatically placed after the sensor
system resets to effectively delay automatic watering until it is actually needed.
TM
Other standard features include a Smart Bypass button that gives you manual control over the
sensor system with a single touch, system status indicators to see at glance that your sensor
system is active and watering is on hold, watering delay to postpone automatic watering from
1 to 5 days, air temperature displayed for rain/freeze sensors and even a Fail-safe mode to allow
irrigation in case the sensor system is not performing properly.
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Getting Started
The wireless rain sensor system is designed for easy installation, setup and years of trouble-free
operation. In most cases, the system components can be installed and fully operational within
minutes. All you will need is a Phillips screwdriver and basic do-it-yourself skills.
If you have problems with any portion of the installation, or the product does not seem to function
properly, refer to the Troubleshooting section on page 22 first. If the problem is not listed, or the
remedy does not help, call Toro Irrigation at 1-951-688-9221 or contact your local Toro
distributor for assistance. For more information on this and other Toro irrigation products, visit
Here’s all there is to it:
Step 1
Step 2
The sensor and receiver are tested at close
The receiver is installed and connected to
your irrigation system controller. See page 5.
range to verify operation. See Page 8.
2
Download from Www.Somanuals.com. All Manuals Search And Download.
Step 4
Step 3
The sensor is adjusted to the preferred
rainfall activation level. See page 11.
A sensor installation site is chosen and the system
is tested again to verify operation. See page 10.
Step 6
Step 5
The operating features are set to your
The sensor module is installed. See page 11.
preferences. See page 14.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Receiver Module Features
1–
Setup Button–Accesses the receiver setup and operating
features.
Adjust Button–Selects settings within the receiver setup
and operating features.
3
4
2–
5
6
7
3– Mast Antenna–Adjusts easily for best signal reception.
4– Digital Display–High-resolution LCD screen provides visual
2
1
reference for sensor system operating features.
5– Sensor Status Indicators– Rain status and Freeze status
(TWRFS-I only) indicators illuminate when the sensor
system is active and automatic watering is on hold.
TM
8
6–
Smart Bypass Button–Multi-functional use. Pressed
to bypass sensor operation, allowing automatic watering to
resume. Switches the Water Delay feature on and off.
7–
Water Conservation LEDs–Indicate the Water
Conservation feature level selected (Minimum, Medium or Maximum).
8– Hinged Cover–Opens downward for receiver control access.
Closed position protects receiver when installed outdoors.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the Receiver Module
Important: Installation of this product must comply with national and local building and
electrical codes. For assistance, contact a professional irrigation system contractor in your area.
The receiver module is suitable for either indoor or outdoor installation. Select a location next to
the controller that provides the following conditions:
• The display screen is clearly visible and the control buttons are easily accessed.
• The connection cable can reach the controller wiring terminal strip without straining.
• The antenna will be unobstructed and is able to be adjusted.
Figure 1
1. Install one of the provided stainless steel screws into the wall at the
intended receiver location. Leave a 3mm gap behind the screw head.
Note: Use screw anchors if installing the receiver on drywall or masonry.
2. Hang the receiver on the screw ensuring the keyhole slot drops down
onto the screw shaft.
3. Install a second screw through the lower tab to secure the receiver.
4. Route the connection cable through the bottom of the controller cabinet
to the wiring connection terminals.
Important: If the receiver module is installed outdoors, be sure to keep the cover in the
closed position when you do not need to view the display or access the control buttons.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Connecting the Receiver Wires
CAUTION: The receiver requires continuous 24 Vac power for operation. Connecting to
higher power will result in irreparable damage. Ensure that power to the controller has
been removed prior to connecting the receiver wires.
The sensor system is designed to work with most makes and models of irrigation controllers.
• If your controller is equipped for a sensor connection, follow the steps in Wiring Procedure I.
• If your controller is not equipped for a sensor connection, use Wiring Procedure II on page 7.
Wiring Procedure I (sensor-ready)
Figure 2 - Normally-closed Sensor
Note: Refer to your controller user’s guide
to determine the type of sensor required:
Normally Closed (NC) or Normally Open (NO).
Jumper
TWRFS-I
PUMP/
MV
1. Locate the sensor connection terminals,
SENSOR
COM
24 VAC
1
2
3
4
usually labeled “SENSOR” or “SN.”
Remove the jumper connector (if installed).
2. Attach the White wire to either Sensor
Red
terminal (disregard +/ – polarity if labeled).
Red
To Valves
3. For a Normally-Closed sensor type , attach the
Brown wire to the remaining Sensor terminal.
Tape back the Yellow wire. See Figure 2.
White
Brown
Yellow
X
6
Download from Www.Somanuals.com. All Manuals Search And Download.
For a Normally-Open sensor type, attach the
Yellow wire to the remaining Sensor terminal.
Tape back the Brown wire. See Figure 3.
Figure 3 - Normally-open Sensor
4. Attach the two Red wires to the 24 Vac
terminals in either order.
Important: Most controllers equipped
for sensor connection provide a switch to
control the sensor circuit. Check the
switch setting to ensure that it is not in
the Bypass or Off position.
Red
Red
To Valves
White
Yellow
Brown
TWRFS-I
Figure 4 - Splice Valve Common
Wiring Procedure II (no Sensor terminals)
1. Locate the valve common wire terminal,
generally labeled “C” or “COM”, and remove
the attached common wire(s).
2. Attach the White wire to this terminal.
Red
To Valves
3. Splice the Brown wire to the common
wire(s) using a wire nut or electrical tape.
Tape back the Yellow wire. See Figure 4.
Red
White
Brown
Yellow
Common to Valves
and Pump/MV
4. Attach the Red wires to the 24 Vac terminals.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Initial Sensor System Test
Before installing the sensor module, test the sensor system to verify operation. Once this test has
been completed satisfactorily, the sensor module can be installed. If a problem occurs during the
test procedure, refer to “Troubleshooting” on page 22.
1. Apply power to the controller. Check controller operation to confirm that it is working properly.
2. When power is applied to the receiver,
Figure 5
Figure 6
the “Min”
Water Conservation indicator will
illuminate. The TWRS-I receiver will display
alternating boxes and the TWRFS-I receiver will
display two flashing bars as shown in Figures 5 and 6.
3. Holding the sensor module next to the receiver, press
and hold the sensor test spindle down for at least 15
seconds to establish communication. See Figure 7.
The Sensor Status indicator will illuminate,
Figure 8
Figure 7
the Antenna icon will flash and the signal strength
bars will appear. The TWRFS-I receiver will display
the current air temperature. See Figure 8.
Figure 9 (TWRS-I)
Figure 10 (TWRFS-I)
4. When the Antenna icon stops flashing, release the
test spindle. The receiver display will appear as
shown in Figures 9 or 10.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Sensor Module Features
1– Rain Threshold Adjustment–Adjusts the rain sensor to
accumulate 3mm, 6mm,12mm or 19mm of rainfall before
signaling the receiver to hold watering. The factory default
setting 6mm.
2
1
2– Sensor Test Spindle–Pressed to manually activate the
sensor for setup and test procedures.
3– Batteries (not shown)–Two 3V lithium batteries, installed
at time of manufacture, will provide approximately five
years of service under normal use conditions.
6
4– Antenna–Positioned downward for maximum signal
transmission strength.
5– Pipe-mount Adapter–Replaces Quick Clip mounting
bracket to enable installation on a length of 13mm thick-
wall PVC pipe.
3
4
TM
6– Quick Clip Mounting Bracket–Simplifies sensor
module installation. Adjustable pivot point for easy
vertical alignment.
5
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Rain Sensor Site Selection
Choosing the right installation site for the sensor module is key to obtaining the maximum benefit
from your sensor system. For best results, choose a sensor installation site that provides:
• Unobstructed exposure to rainfall–away from overhangs, tree branches, etc.
• Protected from irrigation spray, rainwater accumulation and the possibility of submersion.
• Exposure to sunlight and shade conditions similar to the landscape being watered.
• Good communication signal from the sensor to the receiver.
Note: If installing a TWRFS-I rain/freeze sensor specifically for freeze detection, refer to the
additional site selection criteria provided on page 13.
Before installing the sensor module, test the system again to confirm operation by using the
following test procedure:
1. Activate a watering zone that is visible from the intended sensor installation site.
Note: The manual operation mode of some irrigation controllers may bypass the sensor circuit.
If your controller operates like this, set an automatic cycle to start within a minute or two.
2. With the sprinklers on, press and hold the sensor test spindle until the sprinklers shut off.
Note: Irrigation control valves close at various rates. It may require several seconds for the
sprinklers to shut off.
If the test is successful, the sensor is ready to install. If the sprinklers do not shut off, try moving
the sensor a few feet in either direction and test again. Rotating the receiver antenna slightly may
improve the signal strength. Refer to “Troubleshooting” on page 22 for additional information.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the Sensor Module
1. Adjust the sensor module to the preferred rainfall threshold activation point.
The settings, provided in metric on one side of the cap and U.S. standard on
the other, include 3mm, 6mm, 12mm and 19mm. The factory setting is 6mm
and is generally a good starting point. The 3mm setting is not recommended
for high humidity or foggy locations. To adjust, turn the cap to align the
stationary pin with the vertical slot. Guide the cap to the preferred slot
position, then turn it just enough to engage the pin.
Figure 11
2. To install the sensor module on a rain
Figure 13
Figure 12
gutter, position the Quick Clip bracket
on the outer edge of the gutter and
secure by tightening the thumb screw
(Figure 12). Use the provided stainless
steel screws when installing the sensor
on a solid structure, such as a fence or
the side of a roof. See Figure 13.
Thumb
Screw
Note: For optimum signal strength,
the antenna wire should hang straight
down. Ensure the antenna is not in
contact with any metal objects .
11
Download from Www.Somanuals.com. All Manuals Search And Download.
3. To install the sensor on a length of thick-walled PVC pipe, remove and replace the Quick Clip
bracket with the pipe-mount adapter. To provide friction between the components, ensure the
star washer is installed between the adapter and housing tab as shown in Figure 14.
4. Check the sensor module for vertical alignment. To adjust, loosen the bracket screw slightly,
align vertically and tighten screw. See Figure 15.
Figure 14
Figure 15
Star
Washer
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Freeze Sensor (model TWRFS-I) Site Selection
To ensure optimum freeze sensor operation, the sensor module installation site should meet the
site criteria of the rain sensor in addition to the following conditions:
• Located in the coldest portion of the landscape.
• Away from direct exposure to morning sunlight.
• Away from any heat producing or storing device, equipment or appliance such as a pool/spa,
heater, water heater, chimney or hot air vent pipe.
CAUTION: The freeze sensor should be regularly inspected for freeze damage and
manually tested to ensure proper operation.
The freeze sensor system is NOT intended for farm/crop freeze protection and must not be
used for this purpose.
Important: Visual checks and prudent manual watering suspension must be used in
conjunction with any freeze sensor. A freeze sensor should only be relied upon as an aid to
conscientious watering practices, including frequent visual checks.
Air temperatures may be above freezing while the ground and vegetation temperatures remain
below freezing. Due to sensor location and sunlight exposure, actual air temperature may be
lower than measured by the sensor. Operation of the sprinkler system during these conditions may
cause icing. Freeze sensor response time may not coincide with extremely rapid temperature
drop, enabling automatic irrigation to occur.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Temperature Activation Threshold (TWRFS-I models only)
The freeze sensor temperature activation threshold is adjustable from 2°C to 7°C ( 35°F to 45°F).
When the air temperature reaches the threshold setting, the freeze sensor activates the receiver,
and the Freeze Status indicator will turn on. The sensor system will return to the Monitor mode
when the outside air temperature rises above the sensor threshold temperature.
Select Centigrade or Fahrenheit Temperature Scale
Figure 16
1. Press the
Setup button to display the current temperature scale
Setup icon will begin flashing to indicate the
(°C or °F) and the
selected feature can be adjusted. See Figure 16.
2. To select the alternate temperature scale, press the
Select Temperature Threshold
Advance button.
Figure 17
1. Press the
Setup button to display Temperature icon. The display
will indicate the current temperature threshold setting and the
Setup
icon will begin flashing to indicate the selected feature can be adjusted.
See Figure 17.
2. Press the
Advance button to set the sensor threshold temperature.
Congratulations! Your Wireless Rain Sensor system installation is complete. To take advantage
of the unique Water Conservation feature, review the information on the next page to select the
conservation level that best suits your landscape irrigation needs.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Water Conservation Feature – By simply choosing the Minimum (Min), Medium (Med) or
Maximum (Max) conservation level that corresponds to your landscape’s soil type and the sensor
location, a dry-out period, adjusted for actual rainfall duration, is
Figure 18
inserted after the sensor system resets to delay the resumption of
automatic watering.
Each conservation level represents a baseline value that is
automatically adjusted to compensate for rainfall duration.
Min (display number 1) – sets baseline at no days of delay.
Med (display number 2) – sets baseline at one day of delay.
Max (display number 3) – sets baseline at two days of delay.
To assist in choosing which conservation setting to use, review
the chart in Figure 18. First select the landscape soil type. Now,
drop down to the row that best describes the sun/shade coverage
Figure 19
of the sensor location. The level indicated where the two conditions meet is
the suggested starting point. That’s all there is to it!
1. Press the
Setup button to display the
Water Conservation icon.
The display will indicate the current water conservation level setting
and the corresponding level indicator will be illuminated. The
icon will begin flashing to indicate the selected feature can be adjusted.
See Figure 19.
Setup
2. Press the
Adjust button to select level 1, 2 or 3.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Smart Bypass Feature
Figure 20
Once the rain sensor becomes active, it can be easily bypassed by pressing
the
Smart Bypass button. When the rain sensor is bypassed,
the Sensor Status indicator and
flashing. See Figure 20.
Smart Bypass icon will begin
The controller will resume automatic watering operations as scheduled. The rain sensor will stay
in the Bypass mode until it automatically resets to the Monitor mode, or is returned to the active
mode by pressing the
Smart Bypass button again.
Water Delay Feature
The Water Delay feature provides a convenient method of postponing automatic irrigation from
1 to 5 days when rain (or freeze) conditions are expected.
1. Press the
The Setup icon will begin flashing to indicate the selected feature can
be adjusted. See Figure 21.
Setup button to display the
Water Delay icon.
Figure 21
2. Press the
Adjust button to select 1.0 to 5.0 days.
• To activate the Water Delay period, press the
Smart Bypass button.
The number of days remaining in the Water Delay period will countdown as days pass.
Automatic watering will resume as scheduled when 0.0 Water Delay days remain.
• To cancel the Water Delay mode and resume automatic watering operations as scheduled,
press the
16
Smart Bypass button again.
Download from Www.Somanuals.com. All Manuals Search And Download.
Signal Strength Display
This feature displays sensor signal strength on a digital scale ranging from 0.0 to 10.2.
1. Press the
Setup button as needed to display the antenna icon and the
Figure 22
digital readout. The display will indicate the strength of the last received
signal. See Figure 22.
Important: A signal strength value less than 2.0 is may cause
inconsistent operation. Relocate the sensor as needed to increase the
signal strength. See “Troubleshooting” on page 22 for additional information.
Battery Strength Display
This feature displays sensor battery strength on a bar scale. The strength of the battery is indicated
by the height of the bar stack: No bar = a dead battery to six bars = full strength.
1. Press the
the bar scale. See Figure 23.
Note: If the Battery icon is flashing, low battery strength is indicated
Setup button as needed to display the
Battery icon and
Figure 23
and replacement is recommended.
See “Sensor Module Battery Replacement” on page 21.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Dry Out Feature
The Dry Out feature is provided to override the Water Conservation baseline level, allowing the
dry-out delay period to be set with more accuracy from 0.5 to 4.0 days in 0.5-day increments.
Note: Before using the Dry Out feature, allow the sensor system to normalize by cycling through
rain and/or freeze activation several times.
1. Press the
The display will indicate the current Dry Out day setting (factory default is
0.0 days). The Setup icon will begin flashing to indicate the selected
feature can be adjusted. See Figure 24.
Setup button to display the
Dry Out icons.
Figure 24
2. Press the
Adjust button to select the desired value (0.5 to 4.0 days).
Note: Once activated, the Dry Out mode can be canceled by pressing the
Smart Bypass
button.
Note: Changing the Water Conservation level will override the Dry Out feature setting.
Fail Safe Feature
The Fail Safe feature is provided to alert and respond to a loss of communication signal and/or if
the sensor system stays in the active mode for a prolonged period of time. This important feature
safeguards your automatic irrigation system from being inadvertently shut off for an indefinite
period of time due to a rain sensor system malfunction.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Loss of Communication
If the sensor and receiver do not communicate within a 24-hour period, the
sensor system will remain in its current state (Active or Monitor). To alert
Figure 25
you to this condition, the
Warning icon will be displayed. The Antenna
icon and current air temperature (TWRFS-I only) will be flashing and the
signal bar indicator will be cleared. See Figure 25.
Figure 26
If communication is not restored within 48 hours, the sensor system will
automatically revert to the Monitor mode; allowing automatic irrigation to
resume as scheduled. The Warning and Antenna icons will continue to
flash. On the TWRFS-I model, the temperature is replaced with two dashes.
The
Water Conservation indicators will flash in unison. See Figure 26.
Prolonged Active Mode
If the sensor system remains in the Active mode for seven consecutive days,
it will revert to the Monitor mode, allowing the irrigation system to resume
automatic operation.
Figure 27
The Sensor Status indicator will flash continuously and the Warning
icon will be displayed to alert you to this condition. See Figure 27.
Note: A prolonged Active mode generally indicates a stuck sensor.
Check the sensor test spindle to confirm that it moves freely when the sensor discs are dry.
• To reset the receiver, press the Smart Bypass button one time.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Turn the Receiver Module Off and On
1. To turn the receiver module Off, press and hold the
Adjust button until two dashes are
displayed (approximately 5 seconds), then release.
2. To turn the receiver On, press the
Setup button two times. The receiver will return to the
normal display mode within approximately 10 seconds.
Set or Restore the Sensor Address Code
The receiver and sensor modules are factory-matched to communicate using a specific address
code. If you have purchased a new sensor module or if it becomes necessary to reset the address
code, use the following procedure to enable communication:
1. Press and hold the
Smart Bypass button until all three
Figure 28
Water Conservation indicators are illuminated and the
Setup
icon begins blinking (approximately 15 seconds). See Figure 28.
2. Activate the sensor module at close range by pressing the test
spindle until the Sensor Status indicator is illuminated, then release
the test spindle. Refer to step 3 of “Initial System Test” on page 8
for additional information.
Note: If the Water Conservation level is set to Medium or Maximum, or the Dry Out feature is in
use, the sensor system will be activated. Press the
receiver to the Monitor mode.
Smart Bypass button to reset the
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Sensor Module Battery Replacement
Figure 29
1. Unscrew and remove the bottom cap from the sensor
housing.
2. Grasping the edges of the circuit board assembly, carefully
slide the circuit board assembly out of the housing.
3. Remove the battery cover and batteries.
4. Insert two new 3V CR2032 (or equivalent) batteries with
the positive (+) side facing toward the retaining clip.
Note: Properly dispose of the used batteries according
to the battery manufacturer’s recommendations.
5. Install the battery cover.
6. Align the circuit board assembly with the housing guide
slots and carefully insert it into the housing. The circuit
board will fit only when oriented properly. The bottom
edge of the circuit board and housing will be even when
fully inserted.
Battery
Cover
7. Thread the antenna wire through the hole in bottom cap.
Screw the cap onto the housing and tighten by hand.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
If you encounter problems at any point in the installation process, or the components do not
function properly, try the Troubleshooting procedures first. If the problem is not listed or the
remedy does not resolve the problem, contact your local Toro irrigation distributor for assistance.
ꢀ Signal strength is weak or inconsistent.
The Wireless Rain Sensor system has a maximum operating range of 152.4m (500') LOS
(Line-of-Site). Operating range is based on optimum site conditions with no signal interference
present. But in most cases there are buildings in the way or other sources of radio signal
interference, that can reduce the signal range. Most residential and small commercial buildings
will not pose reception problems under normal conditions. However, there are some sites with
buildings or structures constructed of thick, dense walls, or contain electrical equipment that
emits high levels of radio frequency interference. If you are having difficulty obtaining good
signal strength, try the following possible solutions:
• Move the antenna away from any large metal object.
• Avoid indoor receiver locations where cellular or cordless phones have trouble with reception.
• Mount the sensor and receiver modules closer together if possible.
• If the sensor is installed directly over the receiver, move the sensor slightly to either side of
the receiver.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
ꢀ The receiver display is blank.
• Check the 24 Vac power connections. The red power wires from the receiver must be
connected to the controller’s 24 Vac power source. Make sure the power wires are not
connected to the station or pump/master valve terminals. These terminals only provide 24
Vac power when the controller is operating the sprinkler zones.
ꢀ The sensor module does not activate the receiver at close range.
• The receiver module may not recognize the sensor module address code.
See “Set or Restore Sensor Address Code” on page 20.
• Remove and replace the sensor module batteries.
ꢀ The sensor system works, but the controller does not respond to the sensor.
• Check the Yellow or Brown wire connection. The Brown wire must be used for Normally
Closed (NC) controller operation and Yellow wire for Normally Open (NO) operation.
• The Brown wire must be used when splicing into the valve common wire.
• Make sure the controller’s Sensor control switch is not in the Bypass or Off position.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
Models:TWRS-I (Wireless Rain Sensor-International) and TWRFS-I (Wireless Rain/Freeze
Sensor-International)
Wireless Communication Range: Up to 152.4m LOS (line-of-site)
Sensor Type: Industry-standard hygroscopic disc stack with adjustable rainfall sensitivity
Sensor Module Batteries: (2) 3V cells - CR2032 (or equivalent)
Average Battery Life: 5 years
Operating Temperature Range: -29°C to 49°C
Receiver Power: 22–28 Vac/Vdc, 100mA (from controller w/Class 2, UL-approved transformer)
Relay Contacts Output: Normally Open (NO) and Normally Closed (NC) 3A at 24 Vac
Note: The Toro Wireless Rain and Rain/Freeze Sensor series, models TWRS, TWRS-I, TWRFS
and TWRFS-I, are patented with the following U.S. patents pending: 6,452,499, 5,101,083 and
D489,280.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
The Toro Promise – Five-year Limited Warranty
The Toro Company and its affiliate, Toro Warranty Company, pursuant to an agreement between them, jointly warrants, to
the owner, each new piece of equipment (featured in the current catalog at date of installation) against defects in material and
workmanship for for a period described below, provided they are used for irrigation purposes under manufacturer's
recommended specifications. Product failures due to acts of God (i.e., lightning, flooding, etc.) are not covered by this warranty.
Neither Toro nor Toro Warranty Company is liable for failure of products not manufactured by them even though such
products may be sold or used in conjunction with Toro products.
During such warranty period, we will repair or replace, at our option, any part found to be defective. Your remedy is limited
solely to the replacement or repair of defective parts.
Return the defective part to your local Toro distributor, who may be listed in your telephone directory Yellow Pages under
"Irrigation Supplies" or "Sprinkler Systems," or contact The Toro Warranty Company P.O. Box 489, Riverside, California,
92502. For the location of your nearest Toro distributor outside the U.S., call (951) 688-9221.
This warranty does not apply where equipment is used, or installation is performed in any manner contrary to Toro’s
specifications and instructions, nor where equipment is altered or modified.
Neither Toro nor Toro Warranty Company is liable for indirect, incidental or consequential damages in connection with the
use of equipment, including but not limited to: vegetation loss, the cost of substitute equipment or services required during
periods of malfunction or resulting non-use, property damage or personal injury resulting from installer’s actions, whether
negligent or otherwise.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or
exclusion may not apply to you.
All implied warranties, including those of merchantability and fitness for use, are limited to the duration of this express
warranty.
Some states do not allow limitations of how long an implied warranty lasts, so the above limitation may not apply to you.
This warranty gives you specific legal rights and you may have other rights which vary from state to state.
The Toro Wireless Rain Sensor series is covered by this warranty for a period of five years from the date of installation.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Electromagnetic Compatibility
The TWRS-I and TWRFS-I wireless rain sensor series is CISPR 22 class B compliant.
FCC ID: OF7TWRS
IC: 3575A-TWRS
Important: Changes or modifications to this unit, not expressly approved by the party
responsible for compliance, could void the authority to operate the equipment.
Form # 373-0372 Rev. A
Download from Www.Somanuals.com. All Manuals Search And Download.
|