Viking Ventilation Hood VIL1200 User Manual

VIKING MODEL VIL1200  
INLINE FAN  
ONLY FOR USE WITH: VWH, VIH, VBCV, VICV, DTWL AND  
DTWN 24"W TO 66"W WALL AND ISLAND HOODS  
CAUTION  
WARNING  
1. For general ventilating use only. Do not use to exhaust  
hazardous or explosive material and vapors.  
2. To avoid motor bearing damage and noisy and/or  
unbalanced impellers, keep drywall spray, construction  
dust, etc. off power unit.  
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-  
JURY TO PERSONS, OBSERVE THE FOLLOWING:  
1. Use this unit only in the manner intended by the manufac-  
turer. If you have questions, contact the manufacturer or  
your distributor.  
3. Please read specification label on product for additional  
information and requirements.  
2. Before servicing or cleaning unit, switch power off at ser-  
vice panel and lock the service disconnecting means to pre-  
vent power from being switched on accidentally. When the  
service disconnecting means cannot be locked, securely  
fasten a prominent warning device, such as a tag, to the  
service panel.  
3. Installation work and electrical wiring must be done by  
a qualified person(s) in accordance with all applicable  
codes and standards, including fire rated construction  
codes and standards.  
4. Sufficient air is needed for proper combustion and ex-  
hausting of gases through the flue (chimney) of fuel  
burning equipment to prevent backdrafting. Follow the  
heating equipment manufacturer’s guidelines and safety  
standards such as those published by the National Fire  
Protection Association (NFPA), and the American Society  
for Heating, Refrigeration and Air Conditioning Engineers  
(ASHRAE), and the local code authorities.  
4. Unithasanunguardedimpeller. Donotuseinlocationswhere  
the impeller is readily accessible to people or animals.  
5. Screen guards must be installed if impeller is within reach  
of personnel, and less than 7 feet above the floor.  
6. When handling fan wear hand protection and stay  
clear of sharp edges.  
7. Because this unit has rotating parts, safety should be  
exercised during all phases of installation, operation and  
maintenance.  
8. The motor is permanently lubricated. Do not oil or disas-  
semble motor.  
9. Electrical circuit, including speed control, (if used), must  
be rated 5.0 AMPS minimum.  
SPECIFICATIONS  
5
When cutting or drilling into wall, or ceiling, do not  
damage electrical wiring or other hidden utilities.  
MODEL  
VOLTS  
115  
AMPS  
4.84  
CFM  
DUCT SIZE  
10” DIA.  
VIL1200  
1200  
6. Ducted fans must always be vented to the outdoors.  
7. To reduce risk of fire, use only metal ductwork.  
8. This unit must be grounded.  
INSTALLER: Leave this Manual With The Homeowner  
HOMEOWNER: Use And Care Information On Page 4  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONNECT WIRING TO VIL1200 INLINE FAN  
CONNECT WIRING TO THE ROUGH-IN PLATE  
1. The opposite end of this wiring will be connected to the 1. Run 115VAC electrical power cable from the service panel  
rough-in plate in the next step.  
2. Remove wiring box cover from the inline fan.  
and from the inline fan to the rough-in plate part number  
PV300008  
3. Attach an appropriate UL approved cable connector to 2. Remove appropriate knockouts from the range hood rough  
the wiring hole in the wiring box. in box.  
4. Bring electrical wiring through the cable connector in the 3. Attach appropriate UL approved cable connectors to the  
electrical box. wiring holes in the range hood rough-in box.  
5. Make electrical connections per the diagram shown below 4. Feed 6” of power cable through the cable connectors in  
the rough-in plate.  
5. Using the diagram below make all electrical connections  
to the rough-in plate.  
6. Attach wiring box cover.  
6. Attach wiring box cover to rough-in plate.  
7. Attach rough-in plate to the studs at the inside top of  
the range hood with the (4) #10-24 nuts part number  
PV300146 provided.  
8. Connect the plugin power cables of the rough-in kit to  
the range hood.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONNECTING DUCT WORK TO VIL1200 INLINE FAN  
USE AND CARE  
Two duct clamps part number 001377-000 are included  
with this unit and are intended to simplify fan installation  
and isolate fan vibration from the rigid metal duct.  
Disconnect electrical power supply and lock out service panel  
before cleaning or servicing this unit.  
CLEANING  
Note: The duct clamps are  
convenient in installations  
where regular removal of the  
fan in necessary for inspec-  
tion and cleaning.  
Periodic inspection and cleaning is recommended. The fre-  
quency of inspection and cleaning should be adjusted accord-  
ing to the type and amount of cooking.  
8mm  
neoprene pad  
The interior of the fan can to accessed by removing the duct  
The built in hanger tab of the duct clamps are not intended to clamp and gently moving the duct work away from the inlet  
support the weight of the inline fan. The inline fan should be of the fan.  
supported with the integral brackets of the inline fans.  
If excess build up is present it should be removed from the  
If special supports are required in anticipation of earthquakes interior of the fan and from the impeller of the fan.  
the duct clamps that are supplied with the VIL1200 are not  
intended to meet these requirements.  
MOTOR LUBRICATION  
To minimize vibration, leave a 1/4” gap between the inline fan  
collars and rigid duct.  
semble motor.  
The motor is permanently lubricated. Do not oil or disas-  
Tighten the two screws until the fan and duct are snugly attached.  
The duct work at the inlet of the inline fan is to be connected  
to the rough-in plate.  
The duct work at the out box of the inline fan is to be con-  
nected to a roof or wall cap.  
A inline butterfly damper part number PV300006 is included  
with the VIL1200. The damper can be installed anywhere  
in the duct system. Damper must be installed so that the  
airflow direction will open the butterfly blades. Mounting the  
damper in an inverted position may prevent the blades from  
closing completely. The preferred installation position is ver-  
tical as shown below.  
Damper  
Airflow  
Direction  
RSK  
Damper  
Duct  
Collar  
ROUGH-IN  
PLATE  
VIKING RANGE CORPORATION  
GREENWOOD, MISSISSIPPI 38930 USA  
Item #:450355  
Date: 060707  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  

Texas Instruments Computer Drive TMS320DM648 User Manual
Tokina Security Camera KMT 1749 User Manual
Transition Networks Plumbing Product SISTF10xx 141 LRT User Manual
Ultra Products Personal Computer m923 User Manual
Uniden Headphones EXAI 7248 User Manual
Unitech Cash Register ECR 1220 User Manual
ViewSonic MP3 Player VPD500 User Manual
ViewSonic Projector PJ452 User Manual
Vivitar Digital Camera Vivicam 3735 User Manual
VTech Telephone Accessories DS6111 2 User Manual