ONLY FOR USE WITH: VWH, VIH, VBCV, VICV, DTWL AND
DTWN 24"W TO 66"W WALL AND ISLAND HOODS
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive material and vapors.
2. To avoid motor bearing damage and noisy and/or
unbalanced impellers, keep drywall spray, construction
dust, etc. off power unit.
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufac-
turer. If you have questions, contact the manufacturer or
your distributor.
3. Please read specification label on product for additional
information and requirements.
2. Before servicing or cleaning unit, switch power off at ser-
vice panel and lock the service disconnecting means to pre-
vent power from being switched on accidentally. When the
service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the
service panel.
3. Installation work and electrical wiring must be done by
a qualified person(s) in accordance with all applicable
codes and standards, including fire rated construction
codes and standards.
4. Sufficient air is needed for proper combustion and ex-
hausting of gases through the flue (chimney) of fuel
burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer’s guidelines and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Society
for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
4. Unithasanunguardedimpeller. Donotuseinlocationswhere
the impeller is readily accessible to people or animals.
5. Screen guards must be installed if impeller is within reach
of personnel, and less than 7 feet above the floor.
6. When handling fan wear hand protection and stay
clear of sharp edges.
7. Because this unit has rotating parts, safety should be
exercised during all phases of installation, operation and
8. The motor is permanently lubricated. Do not oil or disas-
semble motor.
9. Electrical circuit, including speed control, (if used), must
be rated 5.0 AMPS minimum.
5
When cutting or drilling into wall, or ceiling, do not
damage electrical wiring or other hidden utilities.
MODEL
VOLTS
AMPS
CFM
DUCT SIZE
6. Ducted fans must always be vented to the outdoors.
7. To reduce risk of fire, use only metal ductwork.
8. This unit must be grounded.
HOMEOWNER: Use And Care Information On Page 4
Download from Www.Somanuals.com. All Manuals Search And Download.
1. The opposite end of this wiring will be connected to the 1. Run 115VAC electrical power cable from the service panel
rough-in plate in the next step.
2. Remove wiring box cover from the inline fan.
and from the inline fan to the rough-in plate part number
PV300008
3. Attach an appropriate UL approved cable connector to 2. Remove appropriate knockouts from the range hood rough
the wiring hole in the wiring box. in box.
4. Bring electrical wiring through the cable connector in the 3. Attach appropriate UL approved cable connectors to the
electrical box. wiring holes in the range hood rough-in box.
5. Make electrical connections per the diagram shown below 4. Feed 6” of power cable through the cable connectors in
the rough-in plate.
5. Using the diagram below make all electrical connections
to the rough-in plate.
6. Attach wiring box cover.
6. Attach wiring box cover to rough-in plate.
7. Attach rough-in plate to the studs at the inside top of
the range hood with the (4) #10-24 nuts part number
PV300146 provided.
8. Connect the plugin power cables of the rough-in kit to
the range hood.
Download from Www.Somanuals.com. All Manuals Search And Download.
Two duct clamps part number 001377-000 are included
with this unit and are intended to simplify fan installation
and isolate fan vibration from the rigid metal duct.
Disconnect electrical power supply and lock out service panel
before cleaning or servicing this unit.
Note: The duct clamps are
convenient in installations
where regular removal of the
fan in necessary for inspec-
tion and cleaning.
Periodic inspection and cleaning is recommended. The fre-
quency of inspection and cleaning should be adjusted accord-
ing to the type and amount of cooking.
8mm
neoprene pad
The interior of the fan can to accessed by removing the duct
The built in hanger tab of the duct clamps are not intended to clamp and gently moving the duct work away from the inlet
support the weight of the inline fan. The inline fan should be of the fan.
supported with the integral brackets of the inline fans.
If excess build up is present it should be removed from the
If special supports are required in anticipation of earthquakes interior of the fan and from the impeller of the fan.
the duct clamps that are supplied with the VIL1200 are not
intended to meet these requirements.
MOTOR LUBRICATION
To minimize vibration, leave a 1/4” gap between the inline fan
collars and rigid duct.
semble motor.
The motor is permanently lubricated. Do not oil or disas-
Tighten the two screws until the fan and duct are snugly attached.
The duct work at the inlet of the inline fan is to be connected
to the rough-in plate.
The duct work at the out box of the inline fan is to be con-
nected to a roof or wall cap.
with the VIL1200. The damper can be installed anywhere
in the duct system. Damper must be installed so that the
airflow direction will open the butterfly blades. Mounting the
damper in an inverted position may prevent the blades from
closing completely. The preferred installation position is ver-
tical as shown below.
Damper
Airflow
Direction
RSK
Damper
Duct
Collar
ROUGH-IN
PLATE
GREENWOOD, MISSISSIPPI 38930 USA
Item #:450355
Date: 060707