VENTILATION
Built-In VersaVent™ Rear Downdraft
Standard Features & Accessories
All models include
VIPR161 – 36”W. (fits in most 36”W.
cabinets*)
• Downdraft blower systems are
designed to exhaust airborne
contaminants when cooking with gas
or electric cooktops. They can be
mounted in island, peninsula, or
conventional wall locations.
VIPR models include
• For use with Viking Professional
cooktops
VIPR181 – 48”W. (fits in most 48”W.
cabinets*)
PROFESSIONAL DOWNDRAFT W/REMOTE
VIPR101R – 30”W. (fits in most 30”W.
cabinets*)
VIPR161R – 36”W. (fits in most 36”W.
cabinets*)
VIPR181R – 48”W. (fits in most 48”W.
cabinets*)
DESIGNER DOWNDRAFT W/REMOTE
DIPR100R – 30”W. (fits in most 30”W.
cabinets*)
DIPR160R – 36”W. (fits in most 36”W.
cabinets*)
• Controls on intake top
VIPR(R) models include
• For use with Viking Professional
cooktops & rangetops* (non-grill, non-
wok**)
• Island rangetop must be installed with
island trim
• Remote-mounted control installs on
the countertop prevents you from
having to reach over cooking surface
or vessels
DIPR models include
• For use with Viking Designer cooktops
& rangetops (non-grill, non-wok**)
• Island rangetop must be installed with
island trim
• Remote-mounted control installs on
the countertop prevents you from
having to reach over cooking surface
or vessels
Model numbers
PROFESSIONAL DOWNDRAFT
VIPR101 – 30”W. (fits in most 30”W.
cabinets*)
• Hidden operation—mechanically raises
and lowers from countertop with the
touch of a button
• When not in use, unite retracts and
rests flush with the cooking surface
• Suitable for both island and wall
installations
• Choose from interior- or exterior-
power ventilators (see Installation
Notes & Accessories)
• Filter alert (flashing light) reminds you
to clean filters after approx. 30 hours
of use
DIPR150R – 45”W. (fits in most 45”W.
cabinets*)
*Remote model must be used when
installed with VGRT rangetops.
• Four variable fan speeds ensure
efficient ventilation
• Delay/off feature allows operation for
10 minutes before automatically
shutting off
**If installed behind a gas char-grill or
wok, the warranty will be voided and
performance may be below expectations.
When selecting the power and high
performance of a Viking gas char-grill or
wok, a Viking 18”H. overhead hood is
highly recommended.
• Two removable, easy-to-clean mesh
filters are dishwasher-safe and sized
Model Options
VIPR Professional
Downdraft
VIPR Professional
Downdraft w/Remote
DIPR Designer
Downdraft w/Remote
FINISH DETAILS FOR REMOTE MODELS
• Stainless Steel (SS)
FINISH DETAILS FOR ALL MODELS
• Stainless Steel (SS)
• Black control panel and membrane
with stainless steel trim
o
4”W. x 2-1/2”D.
PLANNING AND DESIGN GUIDE
RELEASED 12/1/07
©2007 VRC— INFORMATION SUBJECT TO CHANGE
V I K I N G R A N G E . C O M
•
1 - 8 8 8 - V I K I N G 1
Download from Www.Somanuals.com. All Manuals Search And Download.
VENTILATION
Built-In VersaVent™ Rear Downdraft
Dimensions & Specifications
CLEARANCE DIMENSIONS
1–3/4”
(4.4 cm)
2”
(5.1 cm)
Countertop
Cooktop
Downdraft
Front to back inside
cabinet depth
1/32”
(0.08 cm
F
IL
R
TE
T
E
R
SE
to
1/16”
)
(
0
.
1
6 cm)
1/32”
(0.08 cm)
to
1/16”
.16
(10.2 cm)
4”
(0
F
IL
T
E
R
1
2
D
P
N
O
W
3
c
4
m)
PROFESSIONAL
PROFESSIONAL &
DESIGNER W/REMOTE
Note: Accurate alignment of cooktop and downdraft is necessary to ensure that there is no interference when air vent
is raised and lowered. There should be a gap of 1/32”–1/16” (.08 cm–0.16 cm) between the back of the cooktop and
the front of the downdraft cover. Rangetops and Designer cooktops must be used with an “R” model downdraft (with
remote control) - mounted into the countertop, at least 4” (10.2 cm) from the burners.
Countertops with a raised lip and/or
backsplash may not allow enough flat
space. Installation requires 2” of flat
countertop behind the cooking surface,
and 1-3/4” between the back edge of the
cooking surface and the inside back of
cabinet. (Viking recommends that
oversized cabinets be used for easier
installation. Also, cooktop depth can vary
greatly, causing the fit of
applicable) must be placed in the
countertop. Do not install it directly
behind or beside a burner or element.
Distance between the controls and the
edge of the cooking surface should be 4”
min.
Important—If installing in a cabinet with
same width as your downdraft model, the
outlet cannot be located on the back wall
of cabinet. In these cases, the downdraft
will cover the entire back wall of the
cabinet, so you must you must either
• mount the electrical box to a side wall or
cabinet floor—at least 12” from the back
wall, or
• mount the electrical box to a wall stud
behind the cabinet, where it will not be
covered by the downdraft, and provide a
clearance hole in the back wall of the
cabinet.
For ducting clearance, check location of
floor joists, wall studs, electrical wiring or
plumbing for possible interference.
cooktop/rangetop and downdraft to be
tight.)
The remote mounted control (if
PLANNING AND DESIGN GUIDE
RELEASED 12/1/07
©2007 VRC— INFORMATION SUBJECT TO CHANGE
V I K I N G R A N G E . C O M
•
1 - 8 8 8 - V I K I N G 1
Download from Www.Somanuals.com. All Manuals Search And Download.
VENTILATION
Built-In VersaVent™ Rear Downdraft
Installation Requirements
VIPR Professional
Downdraft
VIPR Professional
Downdraft w/Remote
DIPR Designer
Downdraft w/Remote
UTILITY REQUIREMENTS
o
o
DUCTING
6” or 10” round elbow= 6’
of straight duct
3-1/4” x 10” to 6” round
transition= 2’ of straight
duct
hardwiring with 2-wire with
ground, using locally-supplied
wire, and connected to the
downdraft plug (included)
• 120 VAC/60 Hz
• Check with a qualified and
trained installer or local codes
for makeup air requirements,
if any.
o
• Max. duct run length (see
Installation Notes &
Accessories)
• For best performance, use the
shortest length of ductwork
and a minimum number of
elbows.
3-1/4” x 10” 90° elbow= 8’
of straight duct
• Max. amp usage (rating does
not include recommended
ventilator kit rating—See
Installation Notes &
• Never use flexible duct; it
creates back pressure/air
turbulence and greatly
reduces performance.
Accessories)
PLUMBING
• The system will operate most
efficiently when the ductwork
does not exceed 40’ of
equivalent duct. For longer
duct runs, increase duct size
and contact a qualified and
trained installer.
• Straight runs and gradual
turns are best; for example,
each 90° elbow is equivalent
to 5’ – 10’ (152.4 – 304.8 cm)
of straight run.
GAS
• Not applicable
• Not applicable
ELECTRICAL
• 2’-long power cord with 3-
pronged plug included
• Internal blowers require a
grounded outlet within reach
of the power cord
• External blowers require direct
Model
Ventilator Kits
Duct Size
Max. Amps
Interior
Exterior
VEDV900
VEDV900
VEDV900/1200
VEDV900
VEDV900
VEDV900/1200
VEDV900
VEDV900
Interior
Exterior
Interior
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
Exterior
5.7
5.7
5.7/3.0
5.7
5.7
5.7/3.0
5.7
5.7
5.7
VIPR101
VIPR161
VIPR181
VIPR101R
VIPR161R
VIPR181R
DIPR100R
DIPR160R
DIPR150R
VIDV500
VIDV500
VIDV500
VIDV500
VIDV500
VIDV500
VIDV500
VIDV500
VIDV500
3–1/4” x 10” (8.3 x 25.4 cm) 10” (25.4 cm)
3–1/4” x 10” (8.3 x 25.4 cm) 10” (25.4 cm)
3–1/4” x 10” (8.3 x 25.4 cm) 10” (25.4 cm)
3–1/4” x 10” (8.3 x 25.4 cm) 10” (25.4 cm)
3–1/4” x 10” (8.3 x 25.4 cm) 10” (25.4 cm)
3–1/4” x 10” (8.3 x 25.4 cm) 10” (25.4 cm)
3–1/4” x 10” (8.3 x 25.4 cm) 10” (25.4 cm)
3–1/4” x 10” (8.3 x 25.4 cm) 10” (25.4 cm)
3–1/4” x 10” (8.3 x 25.4 cm) 10” (25.4 cm)
VEDV900
4.0
Note: Proper installation/ ducting is extremely important to ensure maximum performance. Use a qualified and trained installer.
PLANNING AND DESIGN GUIDE
RELEASED 12/1/07
©2007 VRC— INFORMATION SUBJECT TO CHANGE
V I K I N G R A N G E . C O M
•
1 - 8 8 8 - V I K I N G 1
Download from Www.Somanuals.com. All Manuals Search And Download.
VENTILATION
Built-In VersaVent™ Rear Downdraft
Installation Requirements
PROFESSIONAL ACCESS REQUIREMENTS & SITE PREPARATION
1-1/2”
(3.8 cm)
1-1/2”
(3.8 cm)
27”
(68.6 cm)
7/8”
(2.2 cm)
1-5/16”
(3.3 cm)
2-3/4”
(7.0 cm)
7/8”
(2.2 cm)
27”
(68.6 cm)
27”
(68.6 cm)
2-1/4”
(5.7 cm)
3”
(7.6 cm)
Downdraft: VIPR101R
Rangetop: VGRT300
24”
(61.0 cm)
18-3/4”
(47.6 cm)
Downdraft: VIPR101/101R
Cooktop: VGSU102
20-1/4”
(51.4 cm)
Downdraft: VIPR101/101R
Cooktop: VECU106
28-3/4”
(73.0 cm)
28-1/16”
(73.1 cm)
30”
(76.2 cm)
VIPR101/101R
1-1/2”
(3.8 cm)
1-1/2”
(3.8 cm)
33”
(83.8 cm)
7/8”
(2.2 cm)
1-1/4”
(3.2 cm)
2-3/4”
(7.0 cm)
7/8”
(2.2 cm)
33”
(83.8 cm)
33”
(83.8 cm)
2-1/4”
(5.7 cm)
3”
(7.6 cm)
Downdraft: VIPR161R
Cooktop: VGRT362
24”
(61.0 cm)
Downdraft: VIPR161/161R
Cooktop: VGCU162
Downdraft: VIPR161/161R
Cooktop: VECU166
20-1/4”
(51.4 cm)
18-3/4”
(47.6 cm)
36”
34-3/4”
34-1/4”
(91.4 cm)
(88.3 cm)
(87.0 cm)
VIPR161/161R
1-1/2”
(3.8 cm)
1-1/2”
45”
(3.8 cm)
(114.3 cm)
2-3/4”
(7.0 cm)
TOP EDGE
1/4” (0.6 cm)
DIA. HOLE
1/4” (0.6 cm)
DIA. HOLE
Downdraft: VIPR181R
Cooktop: VGRT482
24”
(61.0 cm)
5/8” (1.6 cm)
DIA. HOLE
CUT OUT ON DOTTED LINE
48”
VIPR181/VIPR181R (121.9 cm)
REMOTE CUTOUT
Model
Downdraft Cutout
Cooktop Cutout
Width
Depth
Width
Depth
VIPR101/101R
w/VECU106
27” (68.6 cm)
27” (68.6 cm)
27” (68.6 cm)
2-1/4” (5.7 cm)
3” (7.6 cm)
28-3/4” (73.0 cm)
28-1/16” (73.1 cm)
30” (76.2 cm)
20-1/4” (51.4 cm)
18-3/4” (47.6 cm)
24” (61.0 cm)
w/VGSU102
w/VGRT300*
VIPR161/161R
w/VECU166
2-3/4” (7.0 cm)
33” (83.8 cm)
33” (83.8 cm)
33” (83.8 cm)
2-1/4” (5.7 cm)
3” (7.6 cm)
34-3/4” (88.3 cm)
34-1/4” (87.0 cm)
36” (91.4 cm)
20-1/4” (51.4 cm)
18-3/4” (47.6 cm)
24” (61.0 cm)
w/VGSU162
w/VGRT362*
VIPR181/VIPR181R
w/VGRT482*
2-3/4” (7.0 cm)
45” (114.3)
2-3/4” (7.0 cm)
48” (121.9 cm)
24” (61.0 cm)
*Must use island trim. Rear countertop trim (supplied with island trim) will be used in this installation.
PLANNING AND DESIGN GUIDE
RELEASED 12/1/07
©2007 VRC— INFORMATION SUBJECT TO CHANGE
V I K I N G R A N G E . C O M
•
1 - 8 8 8 - V I K I N G 1
Download from Www.Somanuals.com. All Manuals Search And Download.
VENTILATION
Built-In VersaVent™ Rear Downdraft
Installation Requirements
DESIGNER ACCESS REQUIREMENTS & SITE PREPARATION
1-1/16”
(2.7 cm)
15/16”
(2.4 cm)
27”
(68.6 cm)
33”
(83.8 cm)
1-1/16”
(2.7 cm)
15/16”
(2.4 cm)
2-1/4”
(5.7 cm)
2-1/4”
(5.7 cm)
Downdraft: DIPR100R
Cooktops:DECU105,
DGCU105, or DGSU100
Downdraft: DIPR160R
Cooktops: DECU165, DGCU165,
or DGSU160
20-5/8”
(52.4 cm)
20-5/8”
(52.4 cm)
29-1/8”
(73.9 cm)
34-7/8”
(88.6 cm)
DIPR100R
DIPR160R
7/16”
(1.1 cm)
42”
(106.7 cm)
7/16”
(1.1 cm)
2-1/4”
(5.7 cm)
TOP EDGE
1/4” (0.6 cm)
DIA. HOLE
1/4” (0.6 cm)
DIA. HOLE
20-5/8”
(52.4 cm)
Downdraft: DIPR150R
Cooktops: DECU155 or DGCU155
5/8” (1.6 cm)
DIA. HOLE
CUT OUT ON DOTTED LINE
42-7/8”
(108.9 cm)
DIPR150R
REMOTE CUTOUT
Model
Downdraft Cutout
Cooktop Cutout
Width
Depth
Width
Depth
DIPR100R
w/DECU105
27” (68.6 cm)
27” (68.6 cm)
27” (68.6 cm)
2-1/4” (5.7 cm)
2-1/4” (5.7 cm)
2-1/4” (5.7 cm)
29-1/8” (73.9 cm)
29-1/8” (73.9 cm)
29-1/8” (73.9 cm)
20-5/8” (52.4 cm
w/DGCU105
w/DGSU100
20-5/8” (52.4 cm)
20-5/8” (52.4 cm)
DIPR160R
w/DECU165
w/DGCU165
w/DGSU160
33” (83.8 cm)
33” (83.8 cm)
33” (83.8 cm)
2-1/4” (5.7 cm)
2-1/4” (5.7 cm)
2-1/4” (5.7 cm)
34-7/8” (88.6 cm)
34-7/8” (88.6 cm)
34-7/8” (88.6 cm)
20-5/8” (52.4 cm)
20-5/8” (52.4 cm)
20-5/8” (52.4 cm)
DIPR150R
w/DECU155
w/DGCU155
42” (106.7 cm)
42” (106.7 cm)
2-1/4” (5.7 cm)
2-1/4” (5.7 cm)
42-7/8” (108.9 cm)
42-7/8” (108.9 cm)
20-5/8” (52.4 cm)
20-5/8” (52.4 cm)
PLANNING AND DESIGN GUIDE
RELEASED 12/1/07
©2007 VRC— INFORMATION SUBJECT TO CHANGE
V I K I N G R A N G E . C O M
•
1 - 8 8 8 - V I K I N G 1
Download from Www.Somanuals.com. All Manuals Search And Download.
VENTILATION
Built-In VersaVent™ Rear Downdraft
Installation Notes & Accessories
✪
Interior-Power Blower Kit
• Stainless Steel (SS)
• Mounts on any size plenum
• 3-1/4” x 10” duct takeoff
• Can transition to 6” round
• Can run duct to left, right, or down
• Max. duct run—40’ (12.2 m)
• Kit includes motor, downdraft plug, and 3-1/4” x 10” collar (for installers who prefer to rivet the ductwork to the
unit.)
Note: Exhaust capacity based on tests with 0.1 static pressure. Without applying static pressure (some brands do not),
CFM could be greatly overstated
Model
Description
Max. amp usage
Approx. ship wt. lbs. (kg)
VIDV500
500* CFM downdraft blower
4.0
32 (14.4)
Exterior-Power Blower Kit
• Stainless Steel (SS)
• Mounts on wall or roof (no roof cap required)
• Comes with 10” round duct takeoff plate, which mounts on any size plenum
• Max. duct run—50’ (15.2 m)
• Kit includes motor, downdraft plug, and 3-1/4” x 10” collar (for installers who prefer to rivet the ductwork to the
unit.)
• VEDV1200 must be used with VIPR181/181R
Note: Exhaust capacity based on tests with 0.1 static pressure. Without applying static pressure (some brands do not),
CFM could be greatly overstated
Model
Description
Max. amp usage
Approx. ship wt. lbs. (kg)
VEDV900
900 CFM downdraft blower
5.7
42 (18.9)
VEDV1200
1200 CFM downdraft blower
3.0
44 (19.8)
Remote Mounted Control
• Replaces standard Designer control
• Gray control panel and membrane with stainless steel trim—coordinates with white Designer cooktops
• Easy to install
• Must be mounted into the countertop, 4” min. from burners
• 4”W. x 2-1/2”D.
Model
Description
Approx. ship wt. lbs. (kg)
DSRCGY
Designer remote mounted control (SS/gray)
1.5 (0.7)
Compliance Information
WARRANTY SUMMARY*
• One-year full warranty—complete product
• Five-year limited warranty—all ventilator motors
• Ninety-day limited warranty—cosmetic parts such as glass, painted, and decorative items
*Must use Viking ventilator kits with Viking downdrafts; use of non-Viking kits voids product warranty. For complete warranty see Use & Care Guide.
Warranty valid on Viking products shipped within the United States and Canada.
PLANNING AND DESIGN GUIDE
RELEASED 12/1/07
©2007 VRC— INFORMATION SUBJECT TO CHANGE
V I K I N G R A N G E . C O M
•
1 - 8 8 8 - V I K I N G 1
Download from Www.Somanuals.com. All Manuals Search And Download.
|