VENTILATION
Built-In Custom Ventilator Systems
Standard Features & Accessories
All models include
•
Must purchase and install an interior-
or exterior-power ventilator (motor) kit
(see Installation Requirements table
for recommendations)
o Power switch and dimmer control
are separate, allowing you to leave
dimmer at favorite position
o See Dimensions & Specifications
table for number of lights per model
Professional models include
Professional-type size, design, and
styling
Heat lamps standard on wall ventilator
systems (bulbs not included)
Commercial-type baffle filter system
efficiently removes grease and heated
vapors from the air; especially
designed for use with commercial-
type products
o See Dimensions & Specifications
table for number of filters per model
Removable trough catches liquefied
grease, making cleanup quick and
easy
Model numbers
PROFESSIONAL CUSTOM WALL
VENTILATOR SYSTEMS (for use with
custom wall hoods)
•
For use with custom hoods
o The look and performance of Viking
ventilation in a blank canvas for
virtually endless overlay options
o Easily installs into almost any custom
hood application
•
•
•
•
•
•
•
VBCV3038—30"W./18"H./22"D.
VBCV3638—36"W./18"H./22"D.
VBCV4238—42"W./18"H./22"D.
VBCV4838—48"W./18"H./22"D.
VBCV5438—54"W./18"H./22"D.
VBCV6038—60"W./18"H./22"D.
VBCV6638—66"W./18"H./22"D.
•
•
•
•
•
Powerful enough to handle even the
most pungent cooking odors
Heat sensor on hood turns ventilator
on full power when cooking
temperatures reach uncomfortable
levels
PROFESSIONAL CUSTOM ISLAND
VENTILATOR SYSTEMS (for use with
custom island hoods)
•
•
•
•
VICV3698—36"W./18"H./29"D.
VICV4298—42"W./18"H./29"D.
VICV5498—54"W./18"H./29"D.
VICV6698—66"W./18"H./29"D.
•
Variable speed controls for custom
venting—separate on/off switch allows
you to leave ventilator at
•
DESIGNER CUSTOM WALL VENTILATOR
SYSTEMS (for use with custom wall
hoods)
favorite/most-used setting
Quiet fans also keep temperatures
down
•
•
Designer models include
Elegant design and styling
12-hour timer built into ventilator
controls
•
•
•
•
•
•
DBCV3082—30"W./12"H./18"D.
DBCV3682—36"W./12"H./18"D.
DBCV4282—42"W./12"H./18"D.
DBCV4882—48"W./12"H./18"D.
Heavy-duty construction
o Virtually seamless stainless steel
design with no visible screws
Easy cleanup
•
•
Delay feature allows you to set the
ventilator to shut off on its own from
10 – 30 minutes later
Dishwasher-safe, stainless steel mesh
filters efficiently remove grease and
heated vapors from the air, and are
easily removed for quick cleaning
o See Dimensions & Specifications
table for number of filters per
model
•
DESIGNER CUSTOM ISLAND VENTILATOR
SYSTEMS (for use with custom island
hoods)
o Design of low-profile filter system
means less interior hood space to
be cleaned
o Stainless steel liner for increased
rigidity, seamless appearance, and
easy cleaning
•
•
•
DICV3632—36"W./12"H./23"D.
DICV4232—42"W./12"H./23"D.
DICV5432—54"W./12"H./23"D.
•
50-watt halogen lights with dimmer
control (bulbs included)
Model Options
VBCV Professional
Custom Wall
Ventilator System
VICV Professional
Custom Island
Ventilator System
DBCV Designer
DICV Designer
Custom Island
Ventilator System
Custom Wall
Ventilator System
FINISH DETAILS
• Designed to be covered by custom
materials—no standard exterior finish
• Stainless steel interior
• See Custom Panels section for more
information and additional
specifications.
P L A N N I N G A N D D E S I G N G U I D E
R E L E A S E D 0 5 / 1 2 / 0 8
© 2 0 0 7 V R C — INFORMATION SUBJECT TO CHANGE
V I K I N G R A N G E . C O M
•
1 - 8 8 8 - V I K I N G 1
Download from Www.Somanuals.com. All Manuals Search And Download.
VENTILATION
Built-In Custom Ventilator Systems
Installation Requirements
VBCV Professional
Custom Wall
Ventilator System
VICV Professional
DBCV Designer
Custom Wall
Ventilator System
DICV Designer
Custom Island
Ventilator System
Custom Island
Ventilator System
UTILITY REQUIREMENTS
Proper installation/ ducting is
extremely important to ensure
maximum performance. Use a qualified
and trained installer.
o Straight runs and gradual
turns are best; for example,
each 90° elbow is equivalent
to 5’ – 10’ (1.52 – 3.05 cm)
of straight run.
• 7” (17.8 cm) round duct for
300 – 600 CFM; 10” for 900 –
1500 CFM
o Never use flexible duct; it
creates back pressure/air
turbulence and greatly
reduces performance.
ELECTRICAL
• Hardwire direct with two-wire
ground
• 120 VAC/60 Hz
• Max. amp usage (rating
includes recommended
ventilator kit rating)—see
Installation Requirements
table
DUCTING
• Check with a qualified and
trained installer or local codes
for makeup air requirements, if
any.
• Max. duct run length
o For 300 – 1,200 CFM—
50’ (152.4 m)
PLUMBING
Not applicable
o
For 1,500 CFM—75’ (22.9 m)
GAS
o Duct run length is for
general reference only;
always use a qualified and
trained installer.
Not applicable
Note: Exhaust capacity based on tests with 0.1 static pressure. Without applying static pressure (some brands do not), CFM could be
greatly overstated.
Model
Ventilator Kits
Duct Size
Max. Amps
Interior
Interior
Exterior
Interior
Exterior
Exterior
VBCV3038
VBCV3638
VBCV4238
VIV300/600/1200*
VIV300/600/1200*
VIV600/1200*
VEV900/1200*
7” (17.8 cm)/
10” (25.4 cm)
7” (17.8 cm)/
10” (25.4 cm)
7” (17.8 cm)/
10” (25.4 cm)
10” (25.4 cm)
10” (25.4 cm)
10” (25.4 cm)
10” (25.4 cm)
7” (17.8 cm)
7” (17.8 cm)
10” (25.4 cm)
10” (25.4 cm)
7” (17.8 cm)
7” (17.8 cm)
7” (17.8 cm)
10” (25.4 cm)
7” (17.8 cm)
7” (17.8 cm)
10” (25.4 cm)
10” (25.4 cm)
5.0/6.2/8.7
5.0/6.2/8.7
6.2/8.7
8.7/6.1
VEV900/1200*
10” (25.4 cm)
10” (25.4 cm)
8.7/6.1
8.7/6.1
VEV900/1200*
VBCV4838
VBCV5438
VBCV6038
VBCV6638
VICV3698
VICV4298
VICV5498
VICV6698
DBCV3082
DBCV3682
DBCV4282
DBCV4882
DICV3632
DICV4232
DICV5432
VIV1200*
VIV1200*
VIV1200*
VIV1200*
VIV600/VIV1200*
VIV600/1200*
VIV1200*
VIV1200*
DIV300/440
DIV300/440
DIV440
VEV1200*/1500
VEV1200*/1500
VEV1200*/1500
VEV1200*/1500
VEV900/1200*
10” (25.4 cm)
10” (25.4 cm)
10” (25.4 cm)
10” (25.4 cm)
10” (25.4 cm)
10” (25.4 cm)
10” (25.4 cm)
10” (25.4 cm)
10” (25.4 cm)
10” (25.4 cm)
10” (25.4 cm)
10” (25.4 cm)
10” (25.4 cm)
10” (25.4 cm)
10” (25.4 cm)
11.1
11.1
11.5
11.5
4.9/7.4
4.9
8.4/9.1
8.4/9.1
8.8/9.5
8.8/9.5
7.4/4.7
7.4/4.8/5.4
5.6/6.2
6.3/7.1
6.6/3.9
6.6/3.9
6.6/3.9
4.3/5.1
7.5/5.2
7.5/5.2/6.0
5.2/6.0
VEV900/1200*/1500
VEV1200*/1500
VEV1200*/1500
DEV900**/1200*
DEV900**/1200*
DEV900**/1200*
DEV1200/1500
8.2
9.0
1.7/3.2
1.7/3.2
3.2
DIV880
5.6
DIV440
DEV900**/1200*
DEV900**/1200/1500
DEV1200/1500
4.0
DIV440
4.0
DIV880
6.4
*1200 CFM interior and exterior (if applicable) ventilator should be used with all outdoor approved models and when indoor models are installed over
ranges/rangetops with gas grill.
**Must use 8” duct from canopy to ceiling – trasition to 10” duct past duct cover.
P L A N N I N G A N D D E S I G N G U I D E
R E L E A S E D 0 5 / 1 2 / 0 8
© 2 0 0 7 V R C — INFORMATION SUBJECT TO CHANGE
V I K I N G R A N G E . C O M
•
1 - 8 8 8 - V I K I N G 1
Download from Www.Somanuals.com. All Manuals Search And Download.
VENTILATION
Built-In Custom Ventilator Systems
Installation Notes & Accessories
%
Ventilator Kits
• See Installation Requirements table for recommendations for each hood model
• One ventilator, one duct run for any size hood/ventilator
• A 1,200 CFM interior or 1,500 CFM exterior (if applicable) ventilator should be used over ranges/rangetops with gas grill
• Must use Viking ventilator kits with Viking hoods; use of non-Viking kits voids product warranty
Kit model
VIV300
Description
Hood models
VBCV3038/3638
Approx. ship wt. lbs. (kg)
300 CFM interior-power
440 CFM interior-power
1200 CFM interior-power
27 (12.2)
27 (12.2)
43 (19.4)
VIV600
VBCV3038/3638/4238 & VCIV3698/4298
VBCV3038/3638/4238/4838/5438/6038/6638 &
VCIV3698/5498/6698
VIV1200
VEV900
900 CFM exterior-power
1200 CFM exterior-power
VBCV3038/3638/4238 & VICV3698/4298
VBCV4838/5438/6038/6638 & VICV3698/4298/
5498/6698
39 (17.6)
53 (23.9)
VEV1200
VEV1500
DIV300
1500 CFM exterior-power
300 CFM interior-power
440 CFM interior-power
880 CFM interior-power
900 CFM exterior-power
1200 CFM exterior-power
1500 CFM exterior-power
VBCV4838/5438/6038/6638 &VICV4298/5498/6698
DBCV3082/3682
47 (21.3)
15 (6.8)
DIV440
DBCV3082/3682/4282 & DICV3632/4232
DBCV4882 & DICV5432
25 (11.3)
36 (16.2)
39 (17.6)
53 (23.9)
53 (23.9)
DIV880
DEV900
DEV1200
DEV1500
DBCV3082/3682/4282 & DICV3632/4232
DBCV3082/3682/4282/4882 & DICV3632/4232/5432
DBCV4882 & DICV4232/5432
Compliance Information
WARRANTY SUMMARY*
• One-year full warranty—complete product
• Five-year limited warranty—all ventilator motors
• Ninety-day limited warranty—cosmetic parts such as glass, painted, and decorative items
*Must use Viking ventilator kits with Viking hoods; use of non-Viking kits voids product warranty. For complete warranty see Use & Care Guide.
Warranty valid on Viking products shipped within the United States and Canada.
P L A N N I N G A N D D E S I G N G U I D E
R E L E A S E D 0 5 / 1 2 / 0 8
© 2 0 0 7 V R C — INFORMATION SUBJECT TO CHANGE
V I K I N G R A N G E . C O M
•
1 - 8 8 8 - V I K I N G 1
Download from Www.Somanuals.com. All Manuals Search And Download.
|