Outdoor Gas Fireplace
Models:
ODGSR36A, ODGSR42A
INSTALLER/CONSUMER
SAFETY INFORMATION
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE.
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.
—Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance
—WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch;
do not use any phone in your
building.
• Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
• If you cannot reach your gas
supplier, call the fire department.
Homeowner's Installation and
Operating Manual
G
E
N
D
—Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
CERTIFIED
C
WARNING: Improper installation,
adjustment, alteration, service or
maintenance can cause injury or
property damage. Read the installation,
operating and maintenance instructions
thoroughly before installing or servicing
this equipment.
E
D
R
E
I
F
I
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
WARNING:
For Outdoor Use ONLY.
20007114 7/06 Rev. 5
Download from Www.Somanuals.com. All Manuals Search And Download.
ODGSR Series Outdoor Gas Fireplace
General Information
This gas appliance should be installed by a qualified
installer in accordance with local building codes and with
current CSA-B149.1 Installation codes for Gas Burning
Appliances and Equipment.
Enclosures for LP-Gas Supply Systems
Enclosures for LP-gas supply cylinders shall be ventilated by
openings at the level of the cylinder valve and at floor level. The
effectiveness of the opening(s) for purposes of ventilation shall
be determined with the LP-gas supply cylinder(s) in place. This
shall be accomplished by one of the following:
FOR U.S.A Installations follow local codes and/or the cur-
rent National Fuel Gas Code. ANSI Z223.1/NFPA 54.
a. One side of the enclosure shall be completely open; or
b. For an enclosure having four sides, a top and a bottom:
1. At least two ventilation openings at cylinder valve level
shall be provided in the side wall, equally sized, spaced at
180 degrees (3.14rad), and unobstructed. Each opening
shall have a total free area of not less than 1/2 square
inch per pound (3.2 sq. cm/kg) of stored fuel capacity and
not less than a total free area of 10 square inches (64.5
sq. cm).
In the Commonwealth of Massachusetts, all gas fittings
and installation of this heater shall only be done by a
licensed gas fitter or licensed plumber.
FOR SAFE INSTALLATION AND OPERATION PLEASE
NOTE THE FOLLOWING:
1. This appliance gives off high temperatures and should be
located out of high traffic areas and away from furniture.
2. Children and adults should be alerted to the hazards of the
high surface temperatures of this appliance and should stay
away to avoid burns or ignition of clothing.
3. Children should be carefully supervised when they are in the
same room as your appliance.
4. Under no circumstances should this appliance be modified.
Parts having to be removed for servicing should be replaced
prior to operating this appliance again.
5. Installation and any repairs to this appliance should be car-
ried out by a qualified service person. A professional service
person should be contacted to inspect this appliance an-
nually. Make it a practice to have all of your gas appliances
checked annually. More frequent cleaning may be required
due to excess lint and dust from carpeting, bedding material,
etc.
6. Control compartments, burners and air passages in this ap-
pliance should be kept clean and free of dust and lint. Make
sure that the gas valve and pilot light are turned off before
you attempt to clean this unit.
7. Keep the area around your appliance clear of combustible
materials, gasoline and other flammable vapor and liquids.
This appliance should not be used as a drying rack for cloth-
ing, nor should Christmas stockings or decorations be hung
in the area of it.
8. Under no circumstances should any solid fuels (wood, coal,
paper or cardboard etc.) be used in this appliance.
9. The flow of combustion and ventilation air must not be ob-
structed in any way.
10. Whether the appliance is installed directly on carpeting, vinyl
tile or any combustible material other than wood, this appli-
ance must be installed on a metal or wood panel extending
the full width and depth of the appliance.
11. This appliance requires adequate ventilation and combus-
tion air to operate properly.
12. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system or
gas control that has been under water.
13. Inspect the burner before each use of the appliance. The
burner must be replaced prior to operation if there is evi-
dence the burner is damaged. Use only burner specified by
manufacturer.
2. Ventilation opening(s) shall be provided at floor level and
shall have a total free area of not less than 1/2 square
inch per pound (3.2 sq. cm/kg) of stored fuel capacity and
not less than a total free area of 10 square inches (64.5
sq. cm). If ventilation openings at floor level are in a side
all, there shall be at least two openings. The bottom of
the openings shall be at floor level and the upper edge no
more than 5 inches (127 mm) above the floor. The open-
ings shall be equally sized, spaced at 180 degrees (3.14
rad) and unobstructed.
3. Every opening shall have minimum dimensions so as to
permit the entrance of a 1/8 inch (3.2 mm) diameter rod.
Cylinder valves shall be readily accessible for hand operation.
A door on the enclosure to gain access to the cylinder valves
is acceptable, provided it is non-locking and can be opened
without the use of tools.
There shall be a minimum clearance of 2 inches (51 mm)
between the lower surface of the floor of the LP-gas supply
cylinder enclosure and the ground.
The design of the appliance shall be such that (1) the LP-gas
supply cylinder(s) can be connected, disconnected and the
connections inspected and tested outside the cylinder enclo-
sure; and (2) those connections which could be disturbed when
installing the cylinder(s) in the enclosure can be leak tested
inside the enclosure.
Description
The ODGSR Series are radiant fireplaces. Do not burn wood
or other materials in these appliances. Each model is available
with standing pilot for use with Natural or Propane gas units.
Report to your dealer any parts damaged in shipment.
Adequate combustion and ventilation air must be provided. The
flow of combustion and ventilation air MUST NOT be obstruct-
ed.
Provide adequate clearances around the air opening into the
combustion chamber; and adequate accessibility clearance for
servicing and proper operation. NEVER obstruct the front open-
ing of the appliance.
This fireplace is not designed to be water tight.
Therefore, when installing this unit against an exte-
rior wall, the wall must be finished before setting unit
LP-cylinder enclosures, if provided by the consumer must con-
form to the design parameters as detailed below.
in place.
3
20007114
Download from Www.Somanuals.com. All Manuals Search And Download.
ODGSR Series Outdoor Gas Fireplace
Fireplace Dimensions
��" (559mm)
Rough
Opening
Depth
48���" (1232mm)
���" (13mm)
�����"
(572mm)
22"
(559mm)
Recessed
Nailing
Flange
���"
(16mm)
�����" (822mm)
Rough Opening Width 41"
(1041mm)
)
Rough
Opening
Height
m
" (16mm)
�
�
m
0
�
4
7
1
(
"
�
�
���"
�
8
6
����"
(191mm)
39���"
(1007mm)
43���"
(1111mm)
Low Voltage
Wire
Access
��"
(622mm)
36"
(914mm)
Low Voltage
Wire Access
14���"
(362mm)
8���"
(210mm)
3���"
(95mm)
14���"
(362mm)
40"
(1016mm)
3���"
(95mm)
����"
(165mm)
Gas Line Access
3���"
(98mm)
Fig. 1 ODGSR36A specification and framing dimensions.
Fireplace Dimensions
�����"
(667mm)
Rough
Opening
Depth
50" (1270mm)
���" (13mm)
�����"
(572mm)
22"
(559mm)
���"
(16mm)
Recessed
Nailing
Flange
35���" (895mm)
Rough Opening Width 47"
(1194mm)
Rough
Opening
Height
" (16mm)
�
�
�
" (1791mm)
�
�
���"
�
�
�
����"
(191mm)
43���"
(1111mm)
39���"
(1007mm)
Low Voltage
Wire
Access
��"
(610mm)
42"
(1067mm)
Low Voltage
Wire Access
14���"
(362mm)
����"
(191mm)
3���"
(95mm)
14���"
(362mm)
3"
(76mm)
46"
(1168mm)
����"
(165mm)
Gas Line Access
Fig. 2 ODGSR42A specification and framing dimensions.
4
20007114
Download from Www.Somanuals.com. All Manuals Search And Download.
ODGSR Series Outdoor Gas Fireplace
Screened Porch Installation
The ODGSR may be installed safely and is design
certified by CSA to be installed in a screened porch with
these guidelines:
Minimum porch area...............................96 sq. feet (9sq m)
Minimum celing height................................. 92" (2,337 mm)
Minimum of two (2) walls must be screened
Minimum top of screen height, side walls....6'6" (1,981 mm)
Minimum screen area .............................64 sq. feet (6sq m)
J
I
H
G
Black Sur-
round Face
F
Mantel
Leg
Clearance to Combustibles
CFM164
Appliances
Top ..........................................................0” (0 mm)
Bottom.....................................................0” (0 mm)
Side.........................................................0” (0 mm)
Back........................................................0” (0 mm)
Perpendicular Sidewall ...........................0” (0 mm)
Top of unit to ceiling ..........................36” (914 mm)
Front of unit to combustibles.............36” (914 mm)
K
L
Side of
Combustion Chamber
M
N
O
Mantels\
WARNING: A 4" hood must be used if a
mantel is to be installed.
The height that a combustible mantel is fitted above the
fireplace is dependent on the depth of the mantel. This
also applies to the distance between the mantel leg (if
fitted) and the fireplace.
CFM170
For the correct mounting height and widths refer to
Figures 3a and 3b
Ref.
Mantel
Leg Depth
Ref.
Mantel Leg From
of Comb. Opening
Noncombustible mantels and legs may be installed at
any height and width around the appliance.
F
G
H
I
14" (356 mm)
12" (305 mm)
10" (254 mm)
8" (203 mm)
1¹⁄₂" (38 mm)
K
L
14" (356 mm)
12" (305 mm)
10" (254 mm)
M
N
O
Side View
8"
(203 mm)
Y
J
1¹⁄₂" (38 mm)
Z
Fig. 3b Combustible mantel leg minimum installation.
When using paint or lacquer to finish the
mantel, such paint or lacquer must be heat
resistant to prevent discoloration.
A
B
Fireplace
Hearth
A hearth is not mandatory but is recommended for
aesthetic purposes. We recommend a noncombustible
hearth.
Top of Combustion
Chamber
CFM146
Ref.
Mantel
Ref.
Mantel From Top
of Comb. Chamber
28" (711 mm)
Shelf Depth
8" (203 mm)
1¹⁄₂" (38 mm)
Y
Z
A
B
26" (660 mm)
Fig. 3a Mantel clearances.
5
20007114
Download from Www.Somanuals.com. All Manuals Search And Download.
ODGSR Series Outdoor Gas Fireplace
Framing and Finishing
Gas Specification
Max. Min.
Fuel Gas Control Input Input
Check appliance to make sure it is levelled
and properly positioned.
Model
ODGSR36ARN Nat. Millivolt Hi/Lo
ODGSR36ARP Prop. Millivolt Hi/Lo
ODGSR42ARN Nat. Millivolt Hi/Lo
ODGSR42ARP Prop. Millivolt Hi/Lo
60,000 42,600
60,000 44,000
60,000 42,600
60,000 44,000
The appliance should only be mounted on the following
surfaces:
• A flat combustible (burnable) surface.
• A raised wooden platform.
• A concrete block or other solid object placed
beneath each of the four corners of the appliance.
Gas Inlet & Manifold Pressures
Natural
LP
Minimum Inlet Pressure
Maximum Inlet Pressure 14.0” w.c.
Manifold Pressure 3.5”w.c.
5.5” w.c.
11.0” w.c.
14.0” w.c.
10.0” w.c.
To mount the appliance:
1. Choose unit location.
2. Four (4) nailing flanges are supplied with the fire-
place (found on the fireplace hearth). To level the
box and secure it firmly in place, remove the nailing
flanges from the hearth and install at the sides of the
fireplace as shown in Figure 4.
ODGSR36A / ODGSR42A
Certified to
CSA 4-96
Units: G01AU6, G01BU6, G01AU2, G01BU2
High Elevations
Nail Top
Input ratings are shown in BTU per hour and are
certified without deration from elevations up to
4,500 feet (1,370 m) above sea level.
Standoffs
Nail Side-
Nailing
Flanges
Nuisance outages may occur at altitudes above
4,500 feet (1,370 m) if dirt, dust, lint and/or cob-
webs are allowed to accumulate on burner and/or
ODS pilot. Monthly inspection and cleaning is rec-
ommended for altitudes above 4,500 feet (1,370 m)
FP549
Fig. 4 Adjustable drywall strip (nailing flange).
Finishing
For elevations above 4,500 feet (1,370 m), instal-
lations must be in accordance with the current
ANSI Z223.1/NFPA 54 and/or local codes having
jurisdiction.
CAUTION: All joints between the finished
wall and the appliance surround (top and
sides) may be sealed only with non-com-
bustible material. Only noncombustible
material can be applied as facing to the ap-
pliance surround (the black painted face).
Valve Access
Valve access can be accomplished in one of two ways:
1. Remove the front panel just below the front of the
hearth pan. This is accomplished by lifting on the
panel. To replace the valve access panel line up the
two pins with the holes in the surround bottom and
push the panel over the front of the hearth pan. (Fig.
5)
Finish the wall with the material of your choice. Refer to
Figures 3a and 3b for specific clearances when install-
ing a combustible mantel or other combustible projec-
tion.
2. Lift the brick with the Majestic logo on it. (Fig. 6)
6
20007114
Download from Www.Somanuals.com. All Manuals Search And Download.
ODGSR Series Outdoor Gas Fireplace
The appliance and its individual shutoff valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in
excess of 1/2 psig (3.45 kPa).
If gas piping from the source to the appliance location
has not been accomplished, install the required pipe.
Consult local plumbing code to assure proper pipe size.
The gas pipeline can be brought in through the right
side of the appliance. A knockout is provided to allow
for the gas pipe installation and testing of any gas con-
nection.
FP1414
NOTE: The gas line connection can be made with 3/8"
copper tubing approved for propane or natural gas, 1/2"
rigid pipe or an approved flex connector, then reduced
to 3/8" to the appliance. Because some municipalities
have some additional local codes, it is always best to
consult your local authority.
Fig. 5 Valve access.
U.S.: Consult the current National Fuel Gas Code, ANSI
Z223.1/NFPA 54.
Canada: CSA - B149.1 installation code.
Test for leaks. Use a 50/50 solution of liquid soap and
water to test for leaks at gas fittings and joints. Apply
water/soap solution with brush only - do not over apply.
NEVER test with an open flame.
Majestic Logo
Brick
FP1415
The gas control is equipped with a captured screw type
pressure test point, therefore it is not necessary to pro-
vide a 1/8" test point up stream of the control.
Fig. 6 Lift brick with logo on it to access valve.
*Do not install
header until unit
is in place.
When using copper or flex connector use only approved
fittings. Always provide a union so that gas line can
be easily disconnected for burner or fan servicing.
See gas specification for pressure details and ratings.
NOTE: If flex connector is used, it must be kept inside
of the appliance. (Fig. 8)
Standoff
Surround
Gas
Line Ac-
cess
Nailing
Flange
1/2" Gas Supply
1/2" x 3/8" Shut-off Valve
3/8" Nipple
3/8" Union
Screen
3/8" Nipple
Grate
Firebox
Valve Access Panel
FP1416
FP598
Fig. 7 Parts identification.
Fig. 8 Typical gas supply installation.
Gas Line Installation
This appliance must be isolated from the gas supply
piping system by closing its individual manual shut off
valve during any pressure equal to or less than 1/2 psig
(3.45 kPa).
7
20007114
Download from Www.Somanuals.com. All Manuals Search And Download.
ODGSR Series Outdoor Gas Fireplace
NOTE: If glass doors are installed, the unit must be
operated with the doors fully open. (Fig. 10) If the
doors are not fully open, the thermodisk will auto-
matically turn the unit off.
Remote Wall Switch
NOTE: Use an approved outdoor switch.
1. Thread wire through the low voltage wire access hole
located on either side of unit. Do not cut wire or insu-
lation on metal edges. Ensure that wire is protected.
Run the other end to a conveniently located wall
receptacle box.
CAUTION: After the unit cools, the burner
will automatically come on.
2. Attach wire to switch and install switch into receptacle
box. Attach cover plate to switch.
3. Connect wiring to gas valve. Refer to Figure 9.
OPEN
CAUTION: Do not wire millivolt remote wall
switch for gas appliance to a 120v power
supply.
Correct
Wrong
For lighting instructions, refer to Page 11.
MD706-7
Fig. 10 Correct door position during operation.
Pilot
Thermodisk
Valve
On/Off
Switch
HV105
Fig. 9 Remote switch wiring.
8
20007114
Download from Www.Somanuals.com. All Manuals Search And Download.
ODGSR Series Outdoor Gas Fireplace
Operating Instructions
Log Installation
Right Cross
Log
1. Remove logs from the packaging.
Left Cross
Log
As with all plastic, these bags
are not toys and should always
be kept away from children and
infants.
2. Place left rear log on rear log support.
Ensure that log is firmly positioned and
there is no side-to-side movement. (Figs.
11 & 12)
Right Rear
Log
3. Carefully place Ember Log between
grate and burner. (Figs. 11 & 12)
Left Rear
Log
4. Place the front of right rear log on the
burner and the back of the log on the
rear log support.
Ember
Log
5. Place the top logs onto the locator
notches. Ensure the logs are secure.
(Fig. 11 & 12)
LG317
Fig. 11 ODGSR36 log placement.
Left Cross
Log
First Firing
Middle Cross Log
Upon completing the gas line connection, a small
amount of air will be trapped in the line. When
first lighting the unit with pilot light, it will take a
few minutes to purge the trapped air. Once purg-
ing is complete, the pilot and burner will light and
operate as indicated in the instruction manual.
Subsequent lightings of the appliance will not
require purging.
Right Cross
Log
Right Rear
Log
When lit for the first time, the appliance will emit
a slight odor for an hour or two. This is due to
paint and lubricants used in the manufacturing
process. After each lighting, vapor may con-
dense and fog the glass; this moisture disap-
pears in a few minutes of burning.
Left Rear
Log
Log Right
Ember
Log Left
Ember
Grate
LG318
Fig. 12 ODGSR42A log placement.
9
20007114
Download from Www.Somanuals.com. All Manuals Search And Download.
ODGSR Series Outdoor Gas Fireplace
Flame Adjustment
3/8"-1/2"
For units equipped with Hi/Lo valves, flame adjustment
is accomplished by rotating the Hi/Lo adjustment knob
located near the center of the gas control.
NOVA SIT Pilot
Turn
counterclockwise
Turn clockwise
to lower
to increase
flame height
flame height
FP581
Fig. 16 Proper pilot flame height.
Fig. 13 Flame adjustment knob for SIT820 valve.
Flame Characteristics
It is important to periodically perform a visual check of
the pilot and the burner flames. Compare them to the il-
lustrations below (Figs. 14, 15, 16). If any of the flames
appear abnormal call a service person.
Red Glow
LG319
Fig. 14 ODGSR36A flame appearance.
LG320
Fig. 15 ODGSR42A flame appearance.
10
20007114
Download from Www.Somanuals.com. All Manuals Search And Download.
ODGSR Series Outdoor Gas Fireplace
Optional Weather Enclosure
Optional Stainless Steel Hood
An optional weather enclosure is available to protect
the burner when not in use.
An optional stainless steel hood is available for both the
ODGSR36A and ODGSR42A.
CAUTION: Do not use the weather enclosure
if the unit has glass doors installed.
NOTE: The stainless steel hood may NOT
be used when the optional glass doors are
installed.
Installation Instructions
Installation Instructions:
1. Turn the unit OFF and allow to cool.
1. Turn the unit off and allow to cool.
2. Grab the weather enclosure by the handle(s).
2. Place the hood so the 2⁵⁄₈" (67 mm) slot clears the
sensor plate located under the fireplace opening on
the top left side. (Fig. 19)
3. Slide the top of the weather enclosure up between
the back of the surround top and the screen rail.
(Fig. 17)
3. Secure the hood to the unit using the three (3) slots
in the hood and the pilot holes in the unit with the
stainless steel sheet metal screws provided. (Fig.
19)
4. Push the bottom of the weather enclosure into the
firebox just enough to clear the valve access cover
and set down. (Fig. 18)
4. Align the sides of the hood so the pilot holes on the
right and left sides of the unit are exposed through
the slots on the ends of the hood. Secure using the
remaining stainless steel sheet metal screws. (Fig.
19)
Surround Top
Weather Enclosure
Screen Rail
Stainless
Steel Hood
KT457
Fig. 17 Place top of weather enclosure between surround top
and screen rail.
Stainless
Steel Sheet
Metal Screws
(5)
Sensor Plate Slot
FP1635
Screen
Fig. 19 Secure stainless steel hood with five (5) sheet metal
screws.
Hearth Brick
Valve Access Cover
KT458
Fig. 18 Push bottom of weather enclosure into firebox.
11
20007114
Download from Www.Somanuals.com. All Manuals Search And Download.
ODGSR Series Outdoor Gas Fireplace
Lighting and Operating Instructions
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING:If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
A. This heater has a pilot which must be lit manu-
ally. When lighting the pilot follow these
•
If you cannot reach your gas supplier, call the
Fire Department
instructions exactly.
C. Use only your hand to push in or turn the gas
control knob. Never use tools. If the knob will not
push in or turn by hand, do not try to repair it, call
a qualified service technician. Applying force or
any attempted repair may result in a fire or explo-
sion.
B. BEFORE LIGHTING smell all around the
heater area for gas. Be sure to smell next to
the floor because some gas is heavier than air
and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
•
•
•
•
Do not try to light any fireplace
Do not touch any electric switch
Do not use any phone in your building
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
D. Do not use this fireplace if any part has been
under water. Immediately call a qualified service
technician to inspect the heater and to replace
any part of the control system and any gas control
which has been under water.
Lighting Instructions
1. STOP! Read the safety information above.
2. Turn OFF all electrical power to the fireplace.
3. For MN/MP/TN/TP appliances ONLY, go on to
Step 4. For RN/RP appliances turn the On/Off
switch to “OFF” position or set thermostat to
lowest level.
10. Push the control knob all the way in and hold.
Immediately light the pilot by repeatedly depress-
ing the piezo spark ignitor until a flame appears.
Continue to hold the control knob in for about one
(1) minute after the pilot is lit. Release knob and it
will pop back up. Pilot should remain lit. If it goes
out, repeat steps 5 through 8.
4. Open control access panel.
5. Push in gas control knob slightly and turn
•
If knob does not pop up when released, stop
clockwise
to "OFF".
3/8" - 1/2"
OFF
PILOT
o
2
O
Honeywell
Euro SIT
SIT NOVA
and immediately call your service technician or
gas supplier.
6. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the floor. If
you smell gas, STOP! Follow "B" in the safety
information above. If you do not smell gas, go
to the next step.
7. Remove glass door before lighting pilot. (See
Glass Frame Removal section).
8. Visibly locate pilot by the main burner.
9. Turn knob on gas control counterclockwise
to "PILOT".
•
If after several tries, the pilot will not stay lit,
turn the gas control knob to "OFF" and call your
service technician or gas supplier.
11. Replace glass door.
12. Turn gas control knob to “ON” position.
13. For RN/RP appliances turn the On/Off switch to
“ON” position or set thermostat to desired setting.
14. Turn on all electrical power to the fireplace.
To Turn Off Gas to Heater
3. Open control access panel.
4. Push in gas control knob slightly and turn
1. Turn the On/Off switch to "OFF" position or set
the thermostat to lowest setting.
clockwise
5. Close control access panel.
to "OFF". Do not force.
2. Turn off all electric power to the fireplace if
service is to be performed.
12
20007114
Download from Www.Somanuals.com. All Manuals Search And Download.
ODGSR Series Outdoor Gas Fireplace
Troubleshooting
Nova SIT 820 Standing Pilot
START
CHECK
Supply Line Hooked up
Shutoff Valve Open
Gas Supply On
NO
YES
Lockout has engaged. Wait 60
seconds and try again.
Piezo not tight enough for good
ground.
Pilot Lights with
Piezo Ignitor
For spark at electrode while
depressing Piezo (Red Button)
1/8" gap to pilot hood needed.
All wiring connections
Replace Piezo Ignitor
Thermodisk
NO
YES
Pilot Stays Lit
YES
For Air in the lines
Thermopile needs a minimum
325mV. Adjust pilot flame height.
All wiring connections
Replace Thermopile
Thermocouple needs a minimum
of 14mV.
Defective valve. Turn to pilot,
meter should read greater than
100mV.
NO
Thermodisk
Wall switch is not turned on.
Watch for grounded wires!
Thermopile needs a minimum
325mV
Pilot Lights Main
Burner
NO
Plugged burner orifice
Doors not fully open (Fig. 10)
YES
System OK
FP396
13
20007114
Download from Www.Somanuals.com. All Manuals Search And Download.
ODGSR Series Outdoor Gas Fireplace
Maintenance
Burner and Burner Compartment
Cleaning the Standing Pilot
Control System
It is important to keep the burner and the burner
compartment clean. At least once per year the logs
should be removed and the burner compartment
vacuumed and wiped out. Remove and replace the logs
as per the instructions in this manual.
The burner and control system consists of:
• main burner
• gas orifice
• pilot burner
• thermopile
Always handle the logs with care as they are fragile
and may also be hot if the fireplace has been in
use.
• combination millivolt gas valve
Cleaning
Most of these components may require only an occa-
sional checkup and cleaning and some may require ad-
justment. If repair is necessary, it should be performed
by a qualified technician.
There are three methods of cleaning the polished stain-
less steel of your outdoor fireplace;
1. Warm, soapy water - to loosen any dirt film
2. Glass cleaner with ammonia
In order to properly clean the burner and pilot assembly,
turn off the gas to the unit, remove logs exposing the
burner and pilot assembly. Clean all foreign materials
from the top of the burner. Check to make sure that
burner parts are clean. Visually inspect pilot. Brush or
blow away any dust or lint accumulation If pilot orifice is
plugged, disassembly may be required to remove any
foreign material from the orifice or tubing.
3. Stainless steel cleaner available at hardware stores
Regardless of which method is used, remember that
anything with too much abrasive may dull the finish.
To obtain proper operation, it is imperative that the pilot
and burner's flame characteristics are steady, not lifting
or floating.
Typically, the top 3/8" or 1/2" of the thermopile should
be engulfed in the pilot flame. (Fig. 16)
To adjust pilot burner, turn pilot screw marked "pilot" for
proper flame size.
The air shutter is set at factory no adjustment should be
necessary.
14
20007114
Download from Www.Somanuals.com. All Manuals Search And Download.
ODGSR Series Outdoor Gas Fireplace
1. ODGSR42A Logs
b
1. ODGSR36A Logs
b
4a/b
a
2
a
d
e
c
d
3
c
h
f
g
25
11
12a/b
7
10
9
6
8
16
19a/b
13
�
�
22
20
�
�
�
�
15
�
14
21
17
7114
18a/b
CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time,
without notice.
ODGSR36A, ODGSR42A
Ref. Description
ODGSR36A
20007180
20007175
20007176
20007178
20007177
--
ODGSR42A
20007200
20007193
20007194
20007197
20007195
20007196
20007198
20007199
--
1. Logs - Complete Set
1a. Log - Left Rear
1b. Log - Right Rear
1c. Log - Right Cross
1d. Log - Left Cross
1e. Log - Middle Cross
1f. Log - Left Ember
1g. Log - Right Ember
--
--
1h. Front Ember Log
20007179
20007119
57803
2. Burner Housing Assembly
3. Ceramic Tile (single)
4a. Burner Orifice - Natural (Manifold & Orifice)
4b. Burner Orifice - LP (Manifold & Orifice)
6. Side Brick - Left
7. Back Brick
8. Side Brick - Right
9. Left Hearth Brick
10. Right Hearth Brick
20007187
57803
20007106
20007159
20002008
20002006
20002007
20007158
20007157
52464
20003547
20003552
20002008
20002019
20002007
20007241
20007240
52464
11. Piezo
12a. Pilot Top Convertible - Natural (3 Way Assembly)
12b. Pilot Top Convertible - LP (3 Way assembly)
13. Thermopile 18"
10002264
10002265
7533113
10002264
10002265
7533113
15
20007114
Download from Www.Somanuals.com. All Manuals Search And Download.
ODGSR Series Outdoor Gas Fireplace
ODGSR36A, ODGSR42A (continued)
Ref. Description
ODGSR36A
10001296
7522432
ODGSR42A
10001296
7522432
14. Pilot Tubing
15. Cable Ignitor 24"
16. Thermocouple 24"
17. Grate
18a. Pilot Orifice - Natural
18b. Pilot Orifice - LP
19a. Valve NOVA - Natural
19b. Valve NOVA - LP
20a. Air Shutter - Natural
21. Hearth Brick Cover
22. Thermodisk
7531137
7531137
20006819
10002268
10002269
7529141
20006819
10002268
10002269
7529141
7529142
7529142
20009120
20007183
20007568
20008549
20008548
20008296
20000129
20007183
20007568
20008551
20008550
20009119
23. Conversion Kit LP to Natural
24. Conversion Kit Natural to LP
25. Valve Access Panel Assy
Contact CFM Corporation for questions concerning prices
and policies covering replacement parts. Parts may be or-
dered through your Majestic Fireplaces distributor or dealer.
Model and serial numbers are listed on the rat-
ing plate (located on right side of combustion
chamber).
You will need the following information when ordering re-
placement parts:
Record your model and serial numbers here for
future reference:
1. The appliance model number.
2. The serial number.
3. A description of the part.
Model #
Serial #
____________________________
____________________________
Should you need additional information beyond what your
dealer can furnish, contact:
CFM Corporation
2695 Meadowvale Blvd.
Mississauga, Ontario, Canada L5N 8A3
Attn: Manager of Customer Service
16
20007114
Download from Www.Somanuals.com. All Manuals Search And Download.
ODGSR Series Outdoor Gas Fireplace
Accessories
The following accessories are available from your local Majestic Fireplaces distributor. Each accessory comes with
a separate installation instruction for mounting to the particular firebox. Be sure to read each instruction thoroughly
before installing.
Accessory
4" Stainless Steel
Hood
Description
For heater up to 40,000 BTU's and mantels
8" high by 12" wide
Model Number
UV36SH4
UV42SH4
Glass Doors
Designed to enhance the look of the fireplace
36GDKSSSR
42GDKSSSR
ODG36WE
ODG42WE
Weather Enclosure Designed to protect the burner when unit is not in use
CAUTION: This firebox is a highly engineered system, and, as such, must be operated only with CFM Cor-
poration approved components. If you use an unapproved component to make any modifications, you may
create a possible fire hazard and will void the CFM Corporation warranty. In addition, such action may void
the coverage provided by the owner's insurance.
17
20007114
Download from Www.Somanuals.com. All Manuals Search And Download.
ODGSR Series Outdoor Gas Fireplace
18
20007114
Download from Www.Somanuals.com. All Manuals Search And Download.
LIMITED LIFETIME WARRANTY
PRODUCT COVERED BY THIS WARRANTY
All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic brand gas fireplaces
equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner.
BASIC WARRANTY
•
If upon inspection, the damage is found to be the fault of the
manufacturer, repairs will be authorized at no charge to the customer
parts and/or labor.
CFM Corporation (hereinafter referred to collectively as the Company)
warrants that your new Vermont Castings or Majestic Gas Fireplace/
Stove is free from manufacturing and material defects for a period of
one year from the date of purchase, subject to the following conditions
and limitations.
•
•
Any part and/or component replaced under the provisions of this
warranty is covered for six months or the remainder of the original
warranty, whichever is longest.
EXTENDED LIFETIME WARRANTY
This warranty is limited to the repair of or replacement of part(s) found
to be defective in material or workmanship, provided that such part(s)
have been subjected to normal conditions of use and service, after
said defect is confirmed by the Company’s inspection.
The heat exchanger, where applicable, and combustion chamber
of every Vermont Castings or Majestic gas product is warranted for
life against through wall perforation. All appliances equipped with an
Insta-Flame Ceramic Burner have limited lifetime coverage on the
ceramic burner plaque. Warrantees are made to the original owner
subject to proof of purchase and the conditions and limitations listed
on this Warranty Document
•
•
The company may, at its discretion, fully discharge all obligations
with respect to this warranty by refunding the wholesale price of the
defective part(s)
Any installation, labor, construction, transportation, or other related
costs/expenses arising from defective part(s), repair, replacement,
or otherwise of same, will not be covered by this warranty, nor shall
the Company assume responsibility for same. Further, the Company
will not be responsible for any incidental, indirect, or consequential
damages except as provided by law.
COMPONENT WARRANTY
CAST IRON: All external and internal cast iron parts are warranted for a
period of three years.
Note: On porcelain enamel finished external parts and accessories
The Company offers no Warranty on chipping of enamel surfaces.
Inspect all product prior to accepting it for any damage to the
enamel.
•
SOME STATES DO NOT ALLOW FOR THE EXCLUSION OR
LIMITATIONS OF INCIDENTALAND CONSEQUENTIAL DAMAGES
OR LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY
LASTS, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOUR
CIRCUMSTANCES. THIS WARRANTY GIVES YOU SPECIFIC
RIGHTSANDYOU MAYHAVE OTHER RIGHTS WHICH VARYFROM
STATE TO STATE.
The salt air environment of coastal areas or a high humidity
environment can be corrosive to the porcelain enamel finish. These
conditions can cause rusting of the cast iron beneath the porcelain
enamel finish, which will cause the finish to flake off.
Dye lot variations with replacement parts and/or accessories can
occur and are not covered by warranty.
•
•
•
•
All other warranties-expressed or implied- with respect to the product,
its components and accessories, or any obligations/liabilities on the
part of the Company are hereby expressly excluded.
GLASS DOORS: Glass doors are covered for a period of one year.
Glass doors are not warranted for breakage due to misuse or accident.
Glass doors are not covered for discoloration or burned in stains due to
environmental issues, or improper cleaning and maintenance.
The Company neither assumes, nor authorizes any third party to
assume on its behalf, any other liabilities with respect to the sale of
this Vermont Castings or Majestic product
BRASS PLATED PARTS AND ACCESSORIES: Brass parts should be
cleaned with Lemon oil only. Brass cleaners cannot be used. Mortar
mix and masonry cleaners may corrode the brass finish. The Company
will not be responsible for, nor will it warrant any brass parts which are
damaged by external chemicals or down draft conditions.
The warranties as outlined within this document do not apply to
chimney components or other non CFM Corporation accessories used
in conjunction with the installation of this product..
Damage to the unit while in transit is not covered by this warranty but
is subject to claim against the common carrier. Contact the dealer
from whom you purchased your fireplace/stove (do not operate the
appliance as this might negate the ability to process the claim with the
carrier).
GAS VALVES: Gas valves are covered for a period of one year
ELECTRONIC AND MECHANICAL COMPONENTS: Electronic and
mechanical components of the burner assembly are covered for one
year. All steel tube burners are warranted for one year.
•
•
The Company will not be responsible for:
a) Down drafts or spillage caused by environmental conditions such
as near-by trees, buildings, roof tops, hills, or mountains.
b) Inadequate ventilation or negative air pressure caused by
mechanical systems such as furnaces, fans, clothes dryers, etc.
ACCESSORIES: Unless otherwise noted all components and CFM
Corporation company supplied accessories are covered for a period of
one year.
CONDITIONS AND LIMITATIONS
This warranty is void if:
a) The fireplace has been operated in atmospheres contaminated by
chlorine, fluorine, or other damaging chemicals.
b) The fireplace has been subjected to prolonged periods of
dampness or condensation
c) Any damages to the fireplace, combustion chamber, heat
exchanger or other components due to water, or weather damage,
which is the result of but not limited to, improper chimney/venting
installation.
•
This new Vermont Castings or Majestic product must be installed by
a competent, authorized, service contractor. A licensed technician, as
prescribed by the local jurisdiction must perform any installation/service
work. It must be installed and operated at all times in accordance with
the Installation and Operating instructions furnished with the product.
Any alteration, willful abuse, accident, or misuse of the product shall
nullify this warranty.
•
•
This warranty is non-transferable, and is made to the original owner,
provided that the purchase was made through an authorized supplier
of the Company.
d) Any alteration, willful abuse, accident, or misuse of the product
has occurred.
IF WARRANTY SERVICE IS NEEDED…
The customer must pay for anyAuthorized Dealer in-home travel fees
or service charges for in-home repair work. It is the dealers option
whether the repair work will be done in the customer’s home or in the
dealer’s shop.
1) Contact your supplier. Make sure you have your warranty,
your sales receipt, and the model/serial number of your
CFM Corporation product.
2) DO NOT ATTEMPT TO DO ANY SERVICE WORK
YOURSELF.
19
20007114
Download from Www.Somanuals.com. All Manuals Search And Download.
CFM Corporation
2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3
Download from Www.Somanuals.com. All Manuals Search And Download.
|