Vermont Casting Indoor Fireplace SDV30 User Manual

INSTALLER / CONSUMER  
SAFETY INFORMATION  
PLEASE READ THIS MANUAL  
BEFORE INSTALLING AND USING  
APPLIANCE.  
Stardance  
Direct Vent/Natural Vent  
Gas Heater  
Model SDV30: 3900-3916, 3940-  
3956  
WARNING!  
IF THE INFORMATION IN THIS  
MANUAL IS NOT FOLLOWED  
EXACTLY, A FIRE OR EXPLOSION  
MAY RESULT CAUSING  
PROPERTY DAMAGE, PERSONAL  
INJURY OR LOSS OF LIFE.  
FOR YOUR SAFETY  
Installation and service must be  
performed by a qualified installer, service  
agency or the gas suppler.  
WHAT TO DO IF YOU SMELL GAS:  
Do not try to light any appliance.  
Do not touch any electric switch; do  
not use any phone in your building.  
Immediately call your gas supplier from  
your neighbor’s phone. Follow the gas  
supplier’s instructions.  
If you cannot reach your gas supplier,  
call the fire department.  
DO NOT STORE OR USE GASO-  
LINE OR OTHER FLAMMABLE  
VAPORS AND LIQUIDS IN THE  
VICINITY OF THIS OR ANY OTHER  
APPLIANCE.  
This appliance may be installed in an after  
market permanently located manufactured  
(mobile) home where not prohibited by  
local codes.  
Homeowner’s Installation  
and Operating Manual  
This appliance is only for use with the  
type of gas indicated on the rating plate.  
This appliance is not convertible for use  
with other gases unless a certified kit is  
used.  
CERTIFIED  
I
INSTALLER: Leave this manual with the appliance.  
CONSUMER: Retain this manual for future reference.  
20007065 1/07 Rev. 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
General Information  
The Stardance Direct Vent/Natural Vent Room Heater, Model  
Nos. 3900-3916, 3940-3956 is a vented gas appliance listed  
to the ANSI standard Z21.88b-2002 and CSA-2.33b-2002 for  
Vented Room Heaters, and CSA 2.17-M91, Gas-Fired Appli-  
ances For Use at High Altitudes.  
WARNING: Operation of this heater when not connected  
to a properly installed and maintained venting system can  
result in carbon monoxide (CO) poisoning and possible  
death.  
The Stardance Direct Vent/Natural Vent Room Heater, when  
installed, must be electrically grounded in accordance with  
local codes or, in the absence of local codes, with the National  
Electrical Code ANSI/NFPA 70, (latest edition), or of the current  
Canadian Electrical Code C22.1.  
The installation of the Stardance Direct Vent/Natural Vent Room  
Heater must conform with local codes, or in the absence of lo-  
cal codes, with National Fuel Gas Code, ANSI Z223.1/NFPA 54  
— latest edition and CSA B-149.1 Installation Code. (EXCEP-  
TION: Do not derate this appliance for altitude. Maintain the  
manifold pressure at 3.5” w.c. for Natural Gas and 10.0” w.c.  
for LP gas at maximum input.) Refer to Page 32 (RF only).  
Due to high temperatures this appliance should be located  
out of traffic and away from furniture and draperies.  
WARNING: This appliance is hot while in operation. Keep  
children, clothing, and furniture away. Contact may cause  
burns or ignition of combustible materials.  
This appliance is only for use with the type of gas indicated on  
the rating plate. This appliance is not convertible for use with  
other gases unless a certified kit is used.  
Children and adults should be alerted to the hazards of  
high surface temperatures and should stay away to avoid  
burns or clothing ignition. Young children should be care-  
fully supervised when they are in the same room as the  
appliance.  
Installation and replacement of gas piping, gas utilization  
equipment or accessories, and repair and servicing of  
equipment shall be performed only by a qualified agency.  
The term “qualified agency” means any individual, firm,  
corporation, or company that either in person or through  
a representative is engaged in and is responsible for (a)  
installation or replacement of gas piping, or (b), the con-  
nection, installation, repair, or servicing of equipment, who  
is experienced in such work, familiar with all precautions  
required, and has complied with all the requirements of the  
authority having jurisdiction.  
Clothing or other flammable materials should not be placed  
on or near the appliance.  
Any safety screen, glass or guard removed for servicing an  
appliance must be replaced prior to operating the appli-  
ance.  
The appliance area must be kept clear and free from com-  
bustible materials, gasoline, and other flammable vapors  
and liquids.  
The Stardance Direct Vent/Natural Vent Room Heater  
should be inspected before use and at least annually by a  
qualified service agency. It is imperative that control com-  
partments, burners, and circulating air passageways of the  
appliance be kept clean.  
The flow of combustion and ventilation air must not be  
obstructed. The installation must include adequate acces-  
sibility and clearance for servicing and proper operation.  
The Stardance Direct Vent/Natural Vent Room Heater and its  
individual shut-off valve must be disconnected from the gas  
supply piping during any pressure testing of that system at test  
pressures in excess of 1/2 psig (3.5 kPa).  
WARNING: Do not operate the Room Heater with the glass  
panel removed, cracked or broken. Replacement of the  
panel should be done by a licensed or qualified service  
person.  
The Stardance Direct Vent/Natural Vent Room Heater must  
be isolated from the gas supply piping system by closing its  
individual manual shutoff valve during any pressure testing of  
the gas supply piping system at test pressures equal to or less  
than 1/2 psig.  
Do not use this appliance if any part has been under water.  
Immediately call a qualified service technician to inspect  
the appliance and to replace any part of the control system  
and any gas control which has been under water.  
Do not burn wood, trash or any other material for which  
this appliance was not designed. This appliance is de-  
signed to burn either natural gas or propane only.  
‘Direct Vent’ describes a sealed combustion system in which  
incoming outside air for combustion and outgoing exhaust enter  
and exit through two separate concentric passages within the  
same sealed vent system. The system does not use room air  
to support combustion. The Direct Vent system permits the  
gas appliance to be vented directly to the outside atmosphere  
through the side of the house or vertically through the roof.  
Conventional venting systems (Natural Vent) take air from the  
room for combustion and vent the exhaust vertically through the  
roof to the atmosphere.  
This gas appliance must not be connected to a chimney  
flue serving a separate solid-fuel burning appliance.  
CAUTION: Label all wires prior to disconnection when  
servicing controls. Wiring errors can cause improper and  
dangerous operation.  
Verify proper operation after servicing.  
Proposition 65 Warning: Fuels used in gas, woodburning or  
oil fired appliances, and the products of combustion of such fu-  
els, contain chemicals known to the State of California to cause  
cancer, birth defects and other reproductive harm.  
This appliance is approved for bedroom installations in the U.S.  
and Canada.  
This appliance may be installed in an aftermarket* manufac-  
tured (mobile) home, where not prohibited by state or local  
codes.  
California Health & Safety Code Sec. 25249.6  
* Aftermarket: Completion of sale, nor for purpose of resale,  
from the manufacturer.  
20007065  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
Stardance Direct Vent / Natural Vent Dimensions  
9"  
(229 mm)  
C
Valve  
Inlet  
L
26"  
(680 mm)  
Valve Inlet  
C
L
3"  
(76 mm)  
14"  
25"  
(355 mm)  
(635 mm)  
Attention  
The Stardance stove is shipped from the factory as a Direct Vent Gas Heater. This heater  
may be converted into a Natural Vent unit in the field. If a Natural Vent heater is desired,  
the Vermont Castings Z31D00 FSDHAG Draft Hood must be directly installed to the top  
of the unit according to the installation instructions. The Draft Hood Adapter is available  
in the 7FSDHASK stove kit or as a separate item.  
When the Stardance stove is converted to Natural Vent, it uses 4” vent pipe. For aes-  
thetic purposes the CFM direct vent system may be used up to the ceiling.  
20007065  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
Installation Requirements  
The installation must conform with local codes or, in  
the absence of local codes, with the National Fuel Gas  
Code, ANSI Z223.1/NFPA 54 - latest edition. (EXCEP-  
TION: Do not derate this appliance for altitude. Main-  
tain the manifold pressure at 3.5 inches w.c. for Natural  
Gas, and 10 inches w.c. for Propane).  
A
D
B
C
In Canada, installation must be in accordance with the  
current CSA B-149.1 Installation Codes and/or local  
codes.  
E
The installation should be done by a qualified ser-  
vice person who is familiar with the building codes  
and installation techniques appropriate for your  
area to accomplish a safe and effective installation.  
ST207  
Fig. 2 Possible stove locations.  
Your dealer or your local gas supplier will be able to  
refer a qualified service person.  
Clearance Requirements  
WARNING: Due to high temperatures, the HEATER  
should be located out of traffic and away from fur-  
niture and draperies.  
Minimum Clearances to Combustible  
Materials  
The surface of the Heater Is hot when it is in use.  
Young children should be watched carefully when  
they are in the same room when the Heater is in  
use, and they should be taught to avoid the hot  
surface. Keep any objects that can burn well away  
from the Heater, and observe the recommended  
clearances that follow.  
Measure side clearances as shown in Figures 3 and 4  
from the outer edge of the cast iron stove top. Measure  
rear clearances from the outermost surface of the steel  
rear skirt.  
The Stardance heater is approved for installation into  
an alcove constructed of combustible materials to the  
dimensions and clearances shown on the next page.  
Locating the Stove  
The same clearances apply in a standard parallel instal-  
lation.  
In choosing a location for the stove, consider:  
The location of outside walls;  
Where additional heat is needed:  
Where family members gather most often;  
The vent system requirements.  
Warning:  
• Always maintain required clearances  
(air spaces) to nearby combustibles to prevent  
fire hazard. Do not fill air spaces with insula-  
tion. All venting components must maintain a  
1” (25 mm) clearance to combustible materials.  
Maintain a 6” (150 mm) clearance when using a  
single wall pipe.  
NOTE: We do not recommend the use of wallpaper  
next to this stove. Over time, radiant heat may cause  
the wallpaper to shrink, or may adversely affect the  
binders in the wallpaper adhesive.  
• The gas appliance and vent system must be  
vented directly to the outside of the building  
and never be attached to a chimney serving a  
separate solid fuel or gas-burning appliance.  
Each direct vent appliance must use its own  
separate vent system. Common vents are pro-  
hibited.  
• Refer to the manufacturer’s instructions in-  
cluded with the venting system for complete  
installation procedures.  
20007065  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
Parallel Installation: Minimum Clearance  
and Flue Centerline, Direct Vent and  
Wall Centerline from Floor  
Direct Vent Only  
Natural Vent  
C
L
C
A
D
A
C
L
B
ST131b  
ST128b  
Effective Minimum  
Wall Thimble  
Centerline  
Stove Clearances:  
Pipe Centerlines:  
A: 4” (102 mm)  
B: 4” (102 mm)  
C: 15¹⁄₂” (395 mm)  
D: 9” (229 mm)  
56” (1480 mm) (CFM Pipe)  
52” (1378 mm) (Simpson Duravent Pipe)  
Fig. 5 Minimum wall thimble centerline.  
Fig. 3 Parallel installation, minimum back and side clear-  
ances, and flue centerlines.  
Wall and Ceiling Clearances  
Corner Installation:  
D
Minimum Clearance and Flue Centerline,  
Direct Vent and Natural Vent  
B
B
C
A
A
B
ST101b  
A: Rear Wall  
4” (102 mm)  
B: Min. Clearance  
C: Min. Alcove Height  
D: Max. Alcove Depth  
Sidewall Clearance  
45¹⁄₄” (1154 mm)*  
72” (1830 mm)  
48” (1220 mm)  
4” (102 mm)  
A
ST129b  
Fig. 5 Dimensions and clearances to ceiling or alcove.  
Stove Clearance: A: 4” (102 mm)  
Hearth Requirements  
Pipe Centerline:  
B: 14¹⁄₂” (370 mm)  
The Stardance Heater must be installed on rigid floor-  
ing. When the heater is installed directly on any com-  
bustible surface other than wood flooring, a metal or  
wood panel extending the full width and depth of the  
unit must be used as the hearth. There are no other  
hearth requirements.  
Fig. 4 Corner installation, minimum corner clearance and flue  
centerline.  
20007065  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
Gas Specifications  
Horizontal Termination -  
Direct Vent ONLY  
Max.  
Min.  
Input Input  
The vent must rise vertically a minimum of 24” (610mm)  
off the top of the unit, before the first elbow. The hori-  
zontal run may extend up to 20’ (6m) and include a  
vertical rise of up to 40’ (12m). (Fig. 7) Horizontal  
termination must also meet the criteria shown in Figures  
9 through 11.  
Model  
SDV30RN  
SDV30RP Prop  
Fuel Gas Control  
BTU/h BTU/h  
28,000 20,000  
28,000 19,000  
Nat  
Millivolt  
Millivolt  
SDV30RFN Nat Comfort Control 28,000 20,000  
SDV30RFP Prop Comfort Control 28,000 19,500  
• Approved vent systems must terminate above and  
including the heavy line in Figure 7.  
Weight: Fully assembled; 202 lbs.  
Gas Inlet and Manifold Pressures  
• Two 45˚ elbows may be substituted for each single  
90˚ elbow.  
Natural  
5.5” w.c.  
14.0” w.c.  
3.5” w.c.  
LP (Propane)  
11.0” w.c.  
14.0” w.c.  
10” w.c.  
• With a rise between 2’ - 5’, one 90˚ or two 45˚ el-  
bows may be used.  
Inlet Minimum  
Inlet Maximum  
Manifold Pressure  
40  
39  
Stardance Direct Vent / Natural Vent  
Certified to:  
38  
37  
ANSI Z21.88-2005 / CSA 2.33-2005  
Vented Gas Fireplace Heaters  
36  
35  
34  
33  
May use up to  
three 90° Elbows  
The installation of your Vermont Castings stove must  
conform with local codes, or in the absence of local  
codes, with the National Fuel Gas Code ANSI Z223.1/  
NFPA 54 - latest edition, or CSA B149.1 Installation  
code. (EXCEPTION: Do not derate this appliance for  
altitude up to 4,500 feet (1,370m). Maintain the mani-  
fold pressure at 3.5” w.c. for Natural Gas and 10.0”  
w.c. for LP Gas.  
32  
31  
30  
29  
28  
27  
26  
25  
24  
23  
22  
21  
20  
19  
18  
16  
15  
14  
13  
12  
11  
10  
9
High Elevations  
Input ratings are shown in BTU per hour and are cer-  
tified without deration for elevations up to 4,500 feet  
(1,370m) above sea level.  
For elevations above 4,500 feet (1,370m) in USA,  
installations must be in accordance with the current  
ANSI Z223.1/NFPA 54 and/or local codes having  
jurisdiction.  
In Canada, please consult provincial and/or local au-  
thorities having jurisdiction for installations at eleva-  
tions above 4,500 feet (1,370m).  
8
7
6
5
4
3
One 90°  
Elbow  
WARNING: Improper installation, adjustment,  
alteration, service or maintenance can cause in-  
jury or property damage. Refer to this manual for  
correct installation and operational procedures.  
For assistance or additional information consult  
a qualified installer, service agency, or the gas  
supplier.  
Unacceptable  
Venting Configureation  
2
1
0
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20  
Horizontal Run (in feet)  
ST134a  
Fig. 7 Horizontal vent termination window.  
20007065  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
Vertical Termination - Direct Vent ONLY  
Vent Termination Clearances  
A vertical vent system must terminate no less than 8’  
(2.44m) and no more than 40’ (12m) above the appli-  
ance flue collar. A 2Z\v” restrictor plate (supplied) must  
be used where specified in all vertically terminated vent  
systems. (Fig. 8) NOTE: The restrictor plate supplied  
with the vertical termination should be discarded. Install  
restrictor plate supplied with stove directly at stove  
outlet. A vertically terminated vent system must also  
conform to the following criteria:  
When planning the installation, consider the location  
of the vent terminal and clearances. Some of the most  
common clearances to keep in mind are shown in Fig-  
ure 10.  
Important: All vent clearances must be maintained.  
Check your vent termination clearances against  
Figures 9 through 11.  
The vent should be placed so that people cannot be  
burned by accidentally touching the vent surfaces when  
the stove is operating.  
• No more than three 90˚ elbows may be used.  
• Two 45˚ elbows may be substituted for one 90˚ el-  
bow. No more than six elbows may be used.  
The vent termination should be located where it cannot  
be damaged by such things as automobile doors, lawn  
mowers or snowblowers and it should be located away  
from areas where it could become blocked by snow,  
etc.  
• Vent must rise a minimum of 2 feet before offset is  
used.  
Termination height must conform to roof clearance  
as specified in Figure 9.  
Some considerations are:  
40  
39  
• Obstructions or impediments to venting.  
• Nearby combustible materials that could come into  
contact with combustion exhaust gases.  
38  
37  
All Vertical Termina-  
tions in this area  
Require use of the  
36  
• Other nearby openings {within 12” (305mm)} through  
which exhaust gas could reenter the building.  
35  
34  
33  
2¹⁄₄” Restrictor Plate*  
• All vegetation within 3’ ((76mm) that may interfere  
with the draft.  
32  
31  
30  
29  
28  
27  
26  
25  
Other factors that influence where the installation will  
be sited include the location of outside walls, where  
additional heat may be desired in the home, where the  
family members gather most regularly, and perhaps  
most importantly, the distance limitations of the venting  
system.  
24  
23  
Vertical Terminations  
22  
must be within this  
21  
IMPORTANT  
area  
20  
19  
18  
16  
15  
Direct Vent Only  
• The horizontal termination must not be recessed  
into the exterior wall or siding.  
14  
• Horizontal vent runs must be level toward the vent  
termination.  
Unacceptable Venting  
13  
Configuration  
12  
11  
10  
9
• Clearances around the vent termination must be  
maintained.  
• For installations using Simpson DuraVent pipe,  
parallel installations with minimum wall clearance  
have restricted access for connecting the Hori-  
zontal Vent Cap straps to the vent pipe. See the  
maker’s instructions for recommended installation  
procedures.  
8
7
6
5
4
3
2
1
0
20  
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19  
ST132a  
Horizontal Run (in feet)  
Fig. 8 Vertical vent termination window.  
*The restrictor Plate is used on Direct Vent Installations  
Only.  
20007065  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
Vent Termination Clearances  
Your stove is approved to be vented either through the  
side wall, or vertical through the roof.  
There must not be any obstruction such as bushes,  
garden sheds, fences, decks or utility buildings within  
24” from the front of the termination hood.  
• CFM Corporation does not require any opening for  
inspection of vent pipe.  
Do not locate termination hood where excessive snow  
or ice build up may occur. Be sure to check vent termi-  
nation area after snow falls, and clear to prevent ac-  
cidental blockage of venting system. When using snow  
blowers, make sure snow is not directed towards vent  
termination area.  
• Only CFM Corporation and Simpson DuraVent vent-  
ing components specifically approved and labelled  
for this stove may be used.  
• Minimum clearances between vent pipes and com-  
bustible materials is one (1”) inch (25 mm), except  
where stated otherwise.  
Location of Vent Termination  
• Venting terminals shall not be recessed into a wall or  
siding.  
It is imperative the vent termination be located observ-  
ing the minimum clearances as shown on this page.  
• Horizontal venting must be installed on a level plane  
without an inclining or declining slope.  
20007065  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
General Venting Information - Termination Location  
INSIDE  
CORNER DETAIL  
G
V
N
H
N
A
D
E
B
V
L
C
B
B
 
�  
V
V
B
V
V
Fixed  
Operable  
Closed  
F
B
M
V
J
X
B
I
K
X
V
A
CFM145a  
AREA WHERE TERMINAL IS NOT PERMITTED  
VENT TERMINATION  
X
AIR SUPPLY INLET  
V
Canadian Installations1  
12” (30cm)  
US Installations2  
12” (30cm)  
A = Clearance above grade, veranda, porch,  
deck, or balcony  
B = Clearance to window or door that may be  
opened  
6” (15cm) for appliances  
6” (15cm) for appliances  
< 10,000 Btuh (3kW), 9”  
(23cm) for appliances > 10,000  
Btuh (3kW) and < 50,000 Btuh  
(15kW), 12” (30cm) for  
< 10,000Btuh (3kW), 12” (30cm)  
for appliances > 10,000 Btuh (3kW) and  
< 100,000 Btuh (30kW), 36” (91cm)  
for appliances > 100,000 Btuh (30kW)  
appliances > 50,000 Btuh (15kW)  
C = Clearance to permanently closed window  
12” (305mm) recommended to  
prevent window condensation  
12” (305mm) recommended to  
prevent window condensation  
D = Vertical clearance to ventilated soffit located  
above the terminal within a horizontal  
distance of 2’ (610mm) from the center  
line of the terminal  
18” (458mm)  
18” (458mm)  
E = Clearance to unventilated soffit  
F = Clearance to outside corner  
G = Clearance to inside corner (see next page)  
12” (305mm)  
see next page  
see next page  
12” (305mm)  
see next page  
see next page  
H = Clearance to each inside of center line  
extended above meter/regulator assembly  
3’ (91cm) within a height of 15’ (5m)  
above the meter/regulator assembly  
3’ (91cm) within a height of 15’  
(5m) above the meter/regulator  
assy  
I = Clearance to service regulator vent outlet  
3’ (91cm)  
3’ (91cm)  
J = Clearance to nonmechanical air supply inlet 6” (15cm) for appliances < 10,000  
to building or the combustion air inlet to any Btuh (3kW), 12” (30cm) for  
6” (15cm) for appliances  
< 10,000 Btuh (3kW), 9”  
(23cm) for appliances > 10,000  
Btuh (3kW) and < 50,000 Btuh  
(15kW), 12” (30cm) for  
other appliances  
appliances > 10,000 Btuh (3kW) and  
< 100,000 Btuh (30kW), 36” (91cm)  
for appliances > 100,000 Btuh (30kW)  
appliances > 50,000 Btuh (15kW)  
K = Clearance to a mechanical air supply inlet  
6’ (1.83m)  
3’ (91cm) above if within 10  
feet (3m) horizontally  
L = Clearance above paved sidewalk or paved 7’ (2.13m)†  
driveway located on public property  
7’ (2.13m)†  
M = Clearance under veranda, porch, deck or  
balcony  
12” (30cm)‡  
12” (30cm)‡  
N = Clearance above a roof shall extend a minimum of 24” (610mm) above the highest point when it passes through the roof  
surface, and any other obstruction within a horizontal distance of 18” (450mm).  
1 In accordance with the current CSA-B149 Installation Codes  
2 In accordance with the current ANSI Z223.1/NFPA 54 National Fuel Gas Codes  
† A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and  
serves both dwellings  
‡ only permitted if veranda, porch, deck or balcony is fully open on a minimum 2 sides beneath the floor:  
NOTE: 1. Local codes or regulations may require different clearances.  
2. The special venting system used on Direct Vent units are certified as part of the appliance, with clearances tested and  
approved by the listing agency.  
3. CFM Corporation assumes no responsibility for the improper performance of the appliance when the venting system does not  
meet these requirements.  
Fig. 9 Vent termination clearances.  
10  
20007065  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
Termination Clearances  
Termination clearances for buildings with combustible and noncombustible exteriors.  
Inside Corner  
Alcove Applications*  
Outside Corner  
D
C
C
F =  
Combustible  
6" (152 mm)  
G =  
Combustible  
6" (152 mm)  
V
G
V
Noncombustible  
2" (51 mm)  
V
E
Noncombustible  
2" (51 mm)  
O
F
Balcony -  
with no side wall  
Balcony -  
with perpendicular side wall  
E = Min. 6” (152 mm) for  
non-vinyl sidewalls  
Min. 12” (305 mm) for  
vinyl sidewalls  
O = 8’ (2.4 m) Min.  
M
No.  
of Caps  
M
V
DMin.  
CMax.  
V
1
2
3
4
3’ (.9 mm) 2 x DActual  
6’ (1.8 m) 1 x DActual  
9’ (2.7 m) 2/3 x DActual  
12’ (3.7 m) 1/2 x DActual  
P
Combustible &  
Noncombustible  
M =  
Combustible &  
Noncombustible  
12" (305 mm)  
M = 24" (610 mm)  
P = 20” (508 mm)  
DMin. = # of Termination caps x 3  
CMax. = (2 / # termination caps) x DActual  
584-15  
*NOTE: Termination in an alcove space (spaces open only on one side and with an overhang) is permitted with the dimensions  
specified for vinyl or non-vinyl siding and soffits. 1. There must be a 3’ (914 mm) minimum between termination caps. 2. All  
mechanical air intakes within 10’ (1 m) of a termination cap must be a minimum of 3’ (914 mm) below the termination cap. 3. All  
gravity air intakes within 3’ (914 mm) of a termination cap must be a minimum of 1’ (305 mm) below the termination cap.  
Fig. 10 Termination clearances.  
Venting Requirements - Natural Vent Only  
 
 
 
 
 
�  
�  
��  
�  
�  
�  
�  
�  
�  
Venting Runs  
A
NOTE: When venting staight vertical, without any  
B
elbow, a minimum of 8 ft. vertical is required  
off the top of the stove.  
= Acceptable venting configuration  
= Unacceptable venting configuration  
A: Vertical installations up to 36 feet (12m) in  
height. Up to an 18 ft. horizontal vent run can be  
installed within the vent system using a  
maximum of two 90-degree elbows or four  
45-degree elbows.  
B: Vertical installations up to 36 feet (12m) in  
height. Up to a 24 ft. horizontal vent run can be  
installed within the vent system using a  
maximum of two 45-degree elbows.  
(Ratio = 2/3, Hor./Vert.)  
�����������������������������������  
Horizontal Run (in feet)  
NOTE: When using the FSDHAG, the restrictor plate  
supplied with the stove is not used.  
Fig. 11 Vent termination window - Natural Vent ONLY.  
20007065  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
Min. Through the Wall Vent Kit  
(1) 90-Degree Elbow (CG)  
(1) 24” Straight pipe (CG)  
7TFSSK  
Venting Requirements and Options -  
Direct Vent ONLY  
(1) 24” - 42” Adjustable Straight Pipe  
(1) Side Wall Termination  
(1) Firestop  
(1) Zero-clearance sleeve  
(1) Hardware package  
Approved Vent System Components  
The Stardance Heater must be vented to the outdoors  
through an adjacent exterior wall or through the roof.  
The venting system must be comprised of the appropri-  
ate listed venting components specified on this page.  
These parts are available from DuraVent Corporation or  
your Vermont Castings Dealer.  
See Figure 4 for dimensions relevant to the standard  
minimum-vent kits.  
Simpson DuraVent Components  
(1) Finishing plate (CG)  
(1) Finishing collar (CG)  
(4) Charcoal Gray flue pipe rings  
Starter Kit for Below Grade Installation  
(1) Snorkel Termination (7TDVSNORK)  
Vertical Termination Kit, 1/12-6/12 Pitch  
(1) Combination Horizontal Offset / Roof Support  
(1) Vertical Termination  
7TDVSKS  
7TDVSKVA  
Minimum Horizontal Vent Kit 2792  
(1) Storm Collar  
(1) 1/12-6/12 Flashing  
(1) Finishing Plate (CG)  
(1) Finishing Collar (CG)  
Starter Pipe Assembly  
(incl. inner & outer sections)  
90° Elbow, Blk.  
45° Elbow, Gal.  
6” Straight, Blk.  
9” Straight, Blk.  
11” - 14B\,” Adjustable Straight Section  
12” Straight  
24” Straight  
36” Straight  
48” Straight  
Horizontal Vent Cap  
Wall Plate  
Vinyl Siding Shield  
Snorkel Termination - 14”  
Snorkel Termination - 36”  
Wall Strap  
Cathedral Ceiling Support Box  
Storm Collar  
2768*  
990B*  
945  
908B*  
907B  
911B  
906  
904B*  
903B  
902  
984*  
940*  
950  
982  
981  
988  
941  
953  
963  
943  
943S  
(1) Polished Brass Flue Pipe Ring  
(1) Hardware Package  
Vertical Termination Kit, 7/12-12/12 Pitch  
(1) 7/12 - 12/12 Flashing  
and all of the other Vertical Termination parts.  
Vertical Termination, Flat Roof  
(1) Flat Flashing  
and all of the other Vertical Termination parts.  
Twist Lock 12” Straight Pipe (CG)  
(1) 12” Non-adjustable Pipe  
Twist Lock 12”-18” Straight Pipe (CG)  
(1) 12” - 18” Adjustable Pipe  
Twist Lock 24” Straight Pipe (CG)  
(1) 24” Non-adjustable Pipe  
Twist Lock 48” Straight Pipe (CG)  
(1) 48” Nonadjustable Pipe  
Twist Lock 45-Degree Elbow (CG)  
for vertical offsets  
(1) 45-degree Elbow  
Draft Hood Adapter  
NV Stove Kit  
(1) 7” Diameter Polished Brass Trim Ring  
(1) 48” Nonadjustable Pipe (CG)  
(1) 24” Nonadjustable Pipe (CG)  
(1) Finishing Plate  
(1) Finishing Collar (CG)  
(1) 90 Degree Elbow (CG)  
Stove Kit  
7TDVSKVB  
7DVSKVF  
7TFSDVP12  
7TFSDVP1218  
7TFSDVP24  
7TFSDVP48  
7TFSDVT45  
Firestop Spacer  
Flashing 0/12 - 6/12  
Flashing 6/12 - 12/12  
Steel Chimney  
Kit A  
Kit B  
FSDHAG  
7FSSK  
931  
932  
933  
934  
991  
980  
Kit C  
Masonry Chimney Kit  
Vertical Termination Cap (High Wind)  
Vertical Termination Cap (Low Profile)  
*Included in Minimum Horizontal Vent Kit #2792  
7FSDHASK  
Includes all parts in the 7FSSK plus the Draft Hood Adapter  
FSDHAG  
Combination Offset/Roof Support  
Attic Insulation Shield  
7” Charcoal Gray Pipe Rings, (4)  
7” Polished Brass Pipe Rings (4)  
Wall Thimble  
All DuraVent Straight vent pipe sections have a net  
length 1¹⁄₂” (37mm) less than the nominal dimension;  
i.e., a 6” (152mm) Straight pipe section has an effective  
length of 4¹⁄₂” (115mm).  
7DVCS  
7DVAIS  
7FSDRG  
7FSDRP  
942G  
CFM Vent Components  
The following kits are available to meet the needs of  
most installations. All pipe has a 7” outer diameter and  
includes a 4” diameter inner section. A (CG) designa-  
tion indicates the part is finished in Charcoal Gray paint.  
Consult your dealer about other vent parts that may be  
appropriate to complete the installation.  
NOTE: Direct vent pipe may be used on the Natural  
Vent system from the top of the draft hood adapter to  
the ceiling.  
20007065  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
4. The rheostat control switch attaches to the left side  
of the valve bracket at the front of the stove. (Fig. 15)  
Install the Optional Fan  
If you are installing the optional convection Fan Kit  
#2767 (FK26), continue here. If you are not installing a  
Fan Kit, go to Page 14, Venting System Assembly.  
1. The fan kit includes a Blower Assembly and a Rheo-  
stat Assembly, connected by a cable. (Fig. 12) The  
Blower Assembly mounts to the bottom rear of the  
stove, and the Rheostat mounts to the valve bracket  
to the left of the valve. The assembly includes a  
‘snapstat’ which automatically turns the fan On (or  
Off) above (or below) approximately 109˚. The Rheo-  
stat also provides a range of fan speed settings from  
Off (which overrides the snapstat function) to High.  
Unpack and inspect the Blower assembly. Confirm  
the fan spins freely.  
Remove retaining nut from shaft of rheostat. (if  
preinstalled)  
Insert the rheostat through the hole in the back  
of the left side of the valve bracket, aligning the  
locator pin with the smaller hole in that bracket.  
Thread the retaining nut onto the shaft of the  
rheostat, tightening with a wrench. Do not over-  
tighten.  
Attach the control knob to the rheostat shaft.  
Use the wire tie to secure the fan and rheostat  
wire harnesses together.  
Rear Skirt  
WARNING  
This appliance is equipped with a three-prong  
(grounded) plug for your protection against shock  
hazard and should be plugged directly into a prop-  
erly grounded three-prong receptacle. Do not cut or  
remove the grounding prong from this plug.  
Sheet Metal  
Screws  
Snapstat Bracket  
Not Used on RF Models  
Snapstat/  
Extension  
Assembly  
Rear Skirt  
ST313  
Insert  
Not Used on  
Stardance  
Fig. 13 Remove rear skirt insert.  
Rheostat  
Assembly  
Star Washer  
Sheet Metal Screws  
2
Snapstat  
1
Phillips  
Pan Head  
Bolts  
1/4” - 20  
Hex Bolt  
Not Used  
on RF  
Models  
Star  
Washer  
Blower  
Snapstat  
Bracket  
Assembly  
Connect to PC Board on  
RF Models Only  
3
ST473  
Fig. 12 Fan kit components.  
NOTE: Shown  
without shell for  
clarification  
2. Remove the rear skirt insert panel at the bottom of  
the Rear Skirt (Fig. 13) and fasten the blower assem-  
bly to the firebox back with the two Phillips pan-head  
bolts originally installed in the firebox back. (‘1’, Fig.  
14)  
ST314  
Fig. 14 Attach the fan assembly and the snapstat.  
NOTE: Steps 3 and 4 do not apply when the RF  
valve is used. After attaching blower assembly to the  
firebox, run the spliced female leads to the front of  
the stove and attach to back of RF valve. (Page 28,  
Fig. 51)  
3. Attach the snapstat assembly to the snapstat bracket  
with two sheet-metal screws. (‘2’, Fig. 15) Attach the  
snapstat bracket to the stove with a hex-head bolt  
passing through the bracket and into the stove base.  
(‘3’, Fig. 14)  
Rheostat Retaining  
Collar  
Rheostat Knob  
ST347a  
Fig. 15 Attach the fan rheostat.  
20007065  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
Venting System Assemlby - Direct Vent  
General Information  
First Section of Vent  
Pipe  
The Stardance is approved for installation only with the  
vent components listed on Page 12. Follow the vent  
component instructions exactly.  
#8 x 1/2” Sheet  
Metal Screws  
For U.S. installations: The venting system must con-  
form with local codes and/or the current National Fuel  
Gas Code, ANSI Z223.1/NFPA 54.  
3” Inner  
Starter PIpe  
For Canadian installations: The venting system must  
conform to the current CSA B149.1 installation code.  
ST211  
Fig. 17 Connect the inner starter with the next section of in-  
ner vent pipe.  
Install the Vent Adapter Pipe  
(CFM Corporation Vent Components)  
1. Install the Restrictor Plate. Consult the ‘Vent Run  
Specifications’ on Page 8 to determine whether the  
restrictor plate is needed. If so, put the restrictor  
plate in place within the inner flue collar as shown in  
Figure 16.  
CEMENT  
ST212  
Fig. 18 Attach inner assembly to flue collar.  
5. Install the Outer Adapter Pipe. Apply a 1/4” bead  
of cement around the inside wall of the pipe, about  
1” from the end. Insert the pipe over the stove flue  
collar, keeping the vertical seam oriented to the back  
of the stove. Also, be sure to align holes on the pipe  
with the holes on the flue collar of the firebox. Fasten  
the pipe to the holes in the flue collar with the #12 x  
1/2” sheet metal screws provided. (Fig. 19)  
ST210  
Fig. 16 Install the restrictor plate only if required for the vent-  
ing configuraiotn. Refer to Page 8.  
2. Attach Inner Starter Pipe, (found in with the log-  
set), to the next section of inner pipe.  
• Run a bead of sealant about 1/2” from the upper  
end of the Inner starter pipe and join the two sec-  
tions together.  
• Drill three pilot holes into the Inner Starter and  
secure the assembly with three sheet metal screws.  
(Fig. 17)  
3. Dry fit the Inner Pipe assembly to the stove for  
the purpose of determining the center line of the  
pipe on the wall.  
• Side Wall Terminations: Dry fit the outer elbow  
with the vertical outer vent and confirm the centerline  
alignment with the wall thimble opening.  
4. Attach the Inner Vent Assembly to the stove.  
• Run a bead of sealant around the bottom end of  
the starter pipe and attach the assembly to the stove  
using three 1/4-20 x 3/8” Phillips screws provided in  
the parts bag. (Fig. 18)  
ST213  
Fig. 19 Fasten outer pipe with #12 x 1/2” sheet metal screw.  
20007065  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
Install the Vent Adapter Pipe  
Side Wall Termination Assembly  
(Simpson Dura-Vent Components)  
1. Locate the vent opening on the wall. Refer to Fig-  
ure 4, Page 6, to determine the opening centerline.  
It may be necessary to first position the stove and  
measure to find the hole location. Depending on  
whether the wall is made of combustible materials,  
cut the opening to the size shown in Figure 23. Com-  
bustible wall openings must be framed as shown in  
Figure 22.  
1. Install the Restrictor Plate. Consult the ‘Vent Run  
Specifications’ on Page 8 to determine whether the  
restrictor plate is needed. If so, put the restrictor  
plate in place within the inner flue collar. (Fig. 16)  
2. Discard the inner starter pipe shipped with the log-  
set. Using the starter pipe assembly listed on Page  
7, slide the inner section out to allow access.  
CFM System  
• Run a bead of sealant around the bottom end of  
the starter pipe and attach the assembly to the stove  
using three 1/4-20 x 3/8” Phillips screws provided in  
the parts bag. (Fig. 20)  
9³⁄₈”  
(240mm)  
9³⁄₈”  
3. Install the Outer Adapter Pipe. Apply a 1/4” bead of  
cement around the outside surface, about one inch  
from the crimped end. (Fig. 21) Orient the vertical  
seam to the rear, and insert the crimped end of the  
outer pipe into the flue collar. Fasten with three sheet  
metal screws provided.  
(240mm)  
Combustible Wall  
10”  
DuraVent  
System  
Framing Detail  
(254 mm)  
Inner Adapter  
Pipe  
7¹⁄₂”  
(191 mm)  
1/4-20 x  
3/8 Phillips  
Screws  
Noncombustible Wall  
VO584-100  
Fig. 22 Locate vent opening.  
CEMENT  
2. Measure the wall thickness and cut the wall sleeve  
sections to proper length (MAXIMUM 12”). Assemble  
the sleeve with the #8 sheet metal screws supplied.  
Attach the firestop plate to the sleeve end with the  
holes. (Fig. 23) NOTE: The wall sleeve is required  
in combustible walls only.  
3. Install the Wall Firestop/Sleeve assembly into the  
wall cutout and fasten the firestop to the wall cutout  
framing members. (Fig. 23)  
ST355a  
Fig. 20 Simpson Dura-Vent - install inner adapter pipe.  
12”  
(305 mm)  
Max. Length  
Sleeve  
#8 Sheet  
Metal Screws  
ST356a  
Fig. 21 Simpson Dura-Vent - install outer adapter pipe.  
Firestop  
ZCS103  
Fig. 23 Assemble the wall sleeve and firestop.  
20007065  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
For DuraVent pipe only: Install vent pipe by aligning  
the locking system together, sliding the pipes togeth-  
er and twisting clockwise.  
• Install 90° elbow. Twist lock as before.  
• Slide the wall plate over horizontal run before at-  
taching the horizontal run to the elbow. Fasten wall  
plate to wall.  
X
4. For CFM Vent Pipe only: If necessary, measure  
to determine the vertical length (X) of pipe required  
from the adapter pipe to the wall cutout centerline,  
including a 2” overlap at the joint. (Fig. 24) use a  
hacksaw or tin snips to trim the pipe as needed.  
ST215  
Fig. 25 Measure the horizontal length.  
Trim Collar  
Wall  
Sleeve  
X
Wall Plate  
ST216  
Fig. 26 Install the horizontal pipe and wall plate parts.  
10. For both CFM and DuraVent Systems: Install  
the vent terminal. (Fig. 27) Apply high temperature  
sealant one inch from the ends of the inner and outer  
collars. Guide the inner and outer vent termination  
collars into the adjacent pipes. Double check that  
the vent pipes overlap the collars by 2”. Fasten the  
termination to the wall with the screws provided, and  
caulk the joint with weatherproof sealant.  
ST214a  
Fig. 24 Determine the vertical pipe length.  
5. Install first the inner then the outer straight pipe  
section(s), trimmed end down, to the point of the el-  
bow. Drill 3 holes through each joint and fasten with  
sheet metal screws.  
11. For CFM only: Install Charcoal Gray Pipe Rings  
(#7FSDRG) or Polished Brass Pipe Rings (#7FS-  
DRP) at pipe joints, if desired.  
6. Seal and install the elbow using 3 sheet metal  
screws at each joint.  
Recessed Wall  
7. Measure, and cut if needed, the appropriate length of  
pipe section needed to make the connection through  
the wall. Include a 2” overlap; i.e. from the elbow  
to the outside wall face, about 2” or the distance  
required if installing a second 90° elbow. (Fig. 25)  
8. Slip the wall plate and trim collar over the interior end  
of the horizontal pipe and install into the wall sleeve.  
Seal the joint inside the wall plate if needed to keep  
cold air from being drawn into the home.  
9. Seal the ends and connect the horizontal pipe to the  
elbow. Fasten the wall plate to the pipe with three  
sheet metal screws. Slide the trim collar up against  
the wall plate to cover the screws. (Fig. 26)  
Caulk Plate Joint with  
Weatherproof Sealant  
ST217  
Fig. 27 Install the vent terminal.  
20007065  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
Vent Termination Below Grade  
Recessed Wall  
Install Snorkel Kit #7FSDVSKS when it is not possible  
to meet the required vent termination clearances of 12”  
(305mm) above grade level. The snorkel kit will allow  
installation depth of down to 7” (178mm) below grade  
level. The seven inches is measured from the center of  
the horizontal vent pipe as it penetrates the wall. If the  
venting system is installed below grade, a window  
well must be installed with adequate and proper  
drainage. (Fig. 28)  
Firestop  
Finishing Collar  
Sheet Metal  
Screws and  
Bracket  
Wall Screws and  
Anchor  
Waterproof Seal  
Around Pipe  
7” Pipe  
NOTE: Be sure to maintain side wall clearances and  
vent run restrictions. Refer to Figures 5, 6, 7, and 8.  
Wall Plate  
ST219  
1. Establish the vent hole through the wall.  
Fig. 29 Use extension brackets to mount snorkel against  
2. Remove soil to a depth of approximately 16”  
(400mm) below the base of the snorkel. Install a  
window well (not supplied). Refill the hole with 12”  
(305mm) of coarse gravel and maintain a clearance  
of at least 4” (100mm) below the snorkel. (Fig. 32)  
recessed wall.  
Vertical (Through the Roof)  
Vent Assembly  
Note that all vertically terminated installations must  
include the restrictor plate included with the stove.  
Refer to Page 8, Figure 8.  
3. Install the vent system as described on Pages 14-17.  
4. Be sure to make a watertight joint around the vent  
pipe joint at the inside and outside wall joints.  
Make certain the vent system conforms to all other  
requirements for vertical termination as specified on  
Page 8.  
5. Apply high temperature sealant around the inner  
and outer snorkel collars. Join the pipes and fasten  
the snorkel termination to the wall with the screws  
provided.  
This installation will require you to first determine the  
roof pitch and use the appropriate vent components.  
Refer to Pages 8 and 10, Figures 8 and 9.  
6. Level the soil to maintain a 4” clearance below the  
snorkel.  
1. Locate the final position of the stove, observing all  
clearances for both the vent and the stove.  
If the foundation is recessed, use extension brackets  
(not supplied) to fasten the lower portion of the snor-  
kel. Fasten the brackets to the wall first, and then  
fasten to the snorkel with self-tapping #8 x 1/2” sheet  
metal screws. Extend the vent pipes out as far as the  
protruding wall face. (Fig. 29)  
2. Plumb to the center of the inner (4”) flue collar from  
the ceiling above, and mark that location.  
3. Cut the opening:  
CFM System: 9³⁄₈” x 9³⁄₈” (240 x 240mm)  
DuraVent System: 10” x 10” (254 x 254mm)  
Wall Screws  
Waterproof Seal  
and Anchors  
4. Plumb any additional opening through the roof or  
other construction that may be needed. In all cases,  
the opening must provide a minimum of 1” (25mm)  
clearance to the vent pipe.  
Around PIpe  
Snorkel  
Firestop  
Termination  
Cap  
5. Place the stove in its final position.  
6. Install firestop(s) #7DVFS and Attic Insulation Shield  
#7DVAIS as needed. (Fig. 30) If there is a room  
above ceiling level, a firestop must be installed on  
both the bottom and top sides of the ceiling joists.  
If an attic is above ceiling level, an attic insulation  
shield must be installed.  
Drain  
Window Well  
7. Install the appropriate roof support and flashing,  
making certain that the upper flange of the flashing  
base is below the shingles. (Fig. 31)  
8. Install appropriate pipe sections until the vent run  
reaches above the flashing. The enlarged ends of  
the vent sections always face downward.  
ST218a  
Fig. 28 Snorkel kit installation.  
20007065  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
9. Install the storm collar and seal around the joints.  
(Fig. 31)  
Venting System Assembly - Natural Vent  
General Information  
10. Add additional vent lengths to achieve the proper  
overall height.  
The Stardance Heater is shipped from the factory as a  
Direct Vent Heater. It may be converted to a Natural  
Vent heater by installing the Vermont Castings Model  
Z31D00 FSDHAG Draft Hood Adapter.  
11. Apply cement to the inner and outer termination col-  
lars and install the terminal cap.  
#7DVAIS  
Attic Insulation  
Shield  
The Stardance Heater is approved for installation as  
a Natural Vent. CFM Direct Vent pipe could be used  
directly after the Draft Hood Adapter up to the ceiling,  
then B-vent pipe must be used. Do not mix types of  
B-vent pipe; use components from one maker or the  
other. Follow the vent component maker’s instructions  
exactly. The heater will also accept standard or enam-  
elled 7” (178mm) diameter pipe, around the Type B  
venting, for decorative purposes only. (Fig. 32)  
#7DVFS  
Firestop in  
Upper Floor  
Use Four  
8dNails  
NOTE: The restrictor plate supplied with the stove  
is not used for Natural Vent applications.  
CFM Direct Vent  
Decorative  
System may be  
7” Pipe  
used after Draft  
Hood up to the  
ceiling  
4” B-vent  
Pipe  
#7DVFS  
Firestop in  
Ceiling  
ST222  
Draft Hood  
Adapter  
Fig. 30 Install firestops and attic insulation shield.  
Use three #5 sheet  
metal screws at  
each joint  
Sealant  
Storm Collar  
Upper  
edge of  
flange  
ST358  
goes under  
upper  
Fig. 32 Decorative 7” pipe may be fitted around the B-vent  
pipe.  
shingles  
The Stardance stove, when installed as a Natural vent  
heater, includes a vent safety switch. (Page 36, Figure  
66) Operating the stove when it is not connected to a  
properly installed and maintained venting system, or  
tampering with or disconnecting the vent safety switch,  
can result in carbon monoxide (CO) poisoning and pos-  
sible death.  
Flashing  
#7DVSKV  
(A, B, or F)  
RoofSupport  
ST221  
Fig. 31 Roof support and flashing.  
For U.S. installations: The venting system must con-  
form with local codes and/or the current National Fuel  
Gas Code, ANSI Z22.1.  
For Canadian installations: The venting system must  
conform to the current CSA B149.1 installation code.  
20007065  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
4. Install the left log by engaging hole on bottom with  
pin on rear log. (Fig. 34) Then set left bottom side  
on the burner so the edge of the log touches the left  
side of the firebox.  
Install the Vent Pipe  
Apply a bead of sealant around bottom end of inner  
starter pipe (found in bag with logset) and attach to  
stove. Apply a bead of sealant around top of inner  
starter pipe and install the Z31D00 FSDHAG Draft  
Hood according to Draft Hood instructions. (Fig. 33)  
5. Loosely sprinkle the lava rocks directly on top of the  
burner in front of and between the decorative grate  
and the right and left logs. Use the lava rock to cover  
brackets on the burner. (Fig. 35)  
Attach the first section of venting to the draft hood. De-  
pending on the length of the individual venting sections  
and the lengths of the decorative pipe (if installed), you  
may need to slip the decorative pipe over the venting  
sections before attaching upper sections to lower ones.  
The sections of decorative pipe should be oriented with  
their seams (if any) toward the wall; sections usually  
do not need to be fastened at each joint, other than  
slip sections. If the layout includes a slip section, this  
should be the last section of pipe visible in the room, at  
the ceiling. Complete the venting according to the vent  
maker’s instructions.  
Lava Rock  
LG142  
Fig. 35 Completed log installation.  
Install the Log Set  
1. Remove the logs from their packaging, and inspect  
each piece for damage. DO NOT INSTALL DAM-  
AGED LOGS.  
Connect the Gas Supply Line  
Check the Rating Plate attached by a steel cable to the  
firebox, to confirm that you have the appropriate firebox  
for the type of fuel to be used. The Stardance may be  
converted from one gas to another using the appropri-  
ate Fuel Conversion Kit listed on Page 39.  
2. Install the rear log centering it side to side on the  
sheet metal shelf at the back of the firebox. (Fig. 34)  
The log will touch both sides and the back wall of the  
firebox.  
CAUTION  
3. Install the right log by engaging hole on bottom with  
pin on the rear log. (Fig. 34) Then set right bottom  
side on the burner so the edge of the log touches the  
right side of the firebox. The right log does not use  
the locator pins on the burner to stay in place.  
This appliance should only be connected  
by a qualified gas technician. Test to  
confirm manifold pressures as specified  
below.  
The Stardance Heater and its individual shutoff  
valve must be disconnected from the gas supply  
piping during any pressure testing of that system  
at test pressures in excess of 1/2 psig (3.5 kPa).  
Left Log  
Right  
Log  
The Stardance Heater must be isolated from the  
gas supply piping system by closing its indi-  
vidual manual shutoff valve during any pressure  
testing of the gas supply piping system at test  
pressure equal to or less than 1/2 psig.  
There must be a gas shutoff between the stove  
and the supply.  
In order to connect Natural Gas, use a fitting with  
3/8” NPT nipple on the valve side and 1/2” natural  
gas supply line with an input of 28,000 BTUs at a  
manifold pressure of 3.5” and minimum inlet sup-  
ply for adjustment of 5.5” w.c.  
Rear Log  
In order to connect Propane, use a fitting with  
3/8” NPT nipple on the valve side and 1/2” pro-  
pane gas supply line with an input of 28,000 BTUs  
at a manifold pressure of 10.0” and minimum inlet  
supply for adjustment of 11.0” w.c.  
Decorative Grate  
LG141  
Fig. 34 Install the back, left and right logs.  
20007065  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
In the U.S.; Gas connection should be made in ac-  
cordance with current National Fuel Gas Code, ANSI  
Z223.1/NFPA 54. Since some municipalities have  
additional local codes, be sure to consult your local  
authority.  
Air Shutter Adjustment Instructions  
To adjust the air shutter, the following procedures  
should be followed:  
1. Remove stove front. Lift stove front up and then  
swing bottom out and away to disengage from the  
stove body. (Fig. 36)  
In Canada; consult the local authority and CSA-B149.1  
installation code.  
Always check for gas leaks with a mild  
soap and water solution. Do not use an  
open flame for leak testing.  
2. Swing open the swiveling latches at the top left and  
right corners of the glass frame. (Page 35, Fig. 62)  
Light the pilot according to the directions on Page 25,  
before going to the next step.  
Burner Information  
The appliance must only use the gas specified on the  
rating plate, unless converted using a Vermont Castings  
Fuel Conversion Kit. To convert from LP to Natural Gas  
use Kit #000-5021. To convert from Natural Gas to LP  
use Kit #000-5022.  
Conversion instructions are provided with each kit and  
beginning on Page 31 in this manual.  
ST474a  
THIS APPLIANCE SHOULD BE CONNECTED TO  
THE GAS SUPPLY ONLY BY A QUALIFIED GAS  
SERVICE TECHNICIAN.  
Fig. 36 Remove stove front.  
3. Pull the top edge of the glass and frame assembly  
away from the firebox, and lift it off its supports on  
the bottom of the firebox face. Place the assembly  
out of the way on a flat, padded surface such as a  
counter protected by a towel.  
THERE MUST BE A GAS SHUT-OFF BETWEEN  
THE STOVE AND THE SUPPLY.  
In order to connect Natural Gas, use a fitting with 3/8”  
NPT nipple on the valve side and 1/2” natural gas sup-  
ply line with an input of 28,000 BTUs at a manifold pres-  
sure of 3.5” and minimum inlet supply for adjustment of  
5.5” w.c.  
4. Take the logset out of the firebox if previously in-  
stalled.  
5. Remove the rear log bracket by unfastening the  
screw. (Fig. 37)  
In order to connect Propane, use a fitting with 3/8”  
NPT nipple on the valve side and 1/2” propane gas  
supply line with an input of 28,000 BTUs at a manifold  
pressure of 10.0” and minimum inlet supply for adjust-  
ment of 11.0” w.c.  
6. Remove the right and left log bracket assembly by  
unfastening the two screws which hold the burner in  
place. (Fig. 37)  
7. Hold the burner at the right hand side and lift to clear  
the right burner leg. Then pull to the right to clear the  
injectors on the left hand side.  
Air Shutter Adjustment  
The Stardance is shipped from the factory with the air  
shutter adjusted to the minimum allowed opening. Refer  
to Table 1. Based on the altitude where the stove is  
located, a shutter adjustment is acceptable to provide a  
mixed balance of flame color/glow. To adjust the shutter  
opening, follow the steps below.  
Remove Screws  
Rear Log Bracket  
Pilot  
NOTE: The air shutter may only be adjusted to a more  
open position. The factory setting is the minimum allow-  
able air shutter opening. (Figs. 38 & 39)  
Table 1. Air Shutter Adjustment  
Minimum rear injector air inlet openings.  
Left & Right Log  
Bracket Assembly  
ST350  
Model  
Natural Gas  
1/2”  
LP  
1/2”  
1”  
Direct Vent  
Natural Vent  
Fig. 37 Remove rear log bracket and left and right log  
bracket assembly.  
1/2”  
20007065  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
8. The air shutter is located on the bottom of the burner  
to the left. Unfasten the two nuts holding the shutter  
in place. The shutter may be adjusted between the  
factory adjusted 1/2” to fully open. Reassemble the  
shutter to allow the rear injector air inlet to close from  
the minimum 1/2” opening to fully open. (Fig. 39) You  
may have to try more than once to find the correct air  
shutter opening for best results depending on your  
altitude.  
Left Burner Leg  
Injector Shoulder  
90°  
Air Shutter  
Refer to  
ST353  
(Original Position)  
Table 1  
Burner  
Fig. 40 Be sure to maintain 90° angle at left burner leg.  
Complete the Assembly  
• Open the swiveling latches (cams) on the top left and  
right corners of the glass frame.  
• Position the glass and frame against the firebox by  
placing the bottom edge on the brackets on the bot-  
tom face of the firebox.  
ST352  
• Swing the assembly against the firebox, and close  
the latches firmly against the pins protruding from the  
firebox top.  
Fig. 38 Air shutter in original from-the-factory position.  
Air Shutter  
Front Injector  
Air Inlet  
(May be adjusted up to fully open)  
Install ON/OFF Switch  
Burner  
The switch assembly parts are found in the parts bag.  
1. Attach switch assembly to left rear side of stove  
shroud (when facing shroud) using two screws and  
existing holes in shroud. (Fig. 41)  
Rear Injector Air Inlet  
2. Run wires down back of stove, under bottom of rear  
shroud to valve.  
ST351  
3. Attach wires to valve terminals. (Fig. 42)  
Fig. 39 Air shutter adjusted.  
9. Refasten the two nuts and assemble the burner into  
the unit by sliding the burner in at an angle with the  
left side lower than the right side. Slide the left side  
onto the injectors. Lower the right hand side down  
into place. Make sure the burner is as far left as pos-  
sible and the injector shoulders are inside the burner.  
NOTE: It is very critical to keep the left burner leg,  
which holds the injectors, at a 90° angle to the base.  
(Fig. 40) This keeps the orifices aligned with tubes  
on the inside of the burner. Failure to do so could  
affect the flame appearance and performance of the  
unit.  
Switch  
Existing Holes  
Assembly  
Screws  
ST315  
Fig. 41 Attach switch assembly to rear shroud.  
10.Refasten the right and left log bracket assembly.  
11.Refasten the rear log bracket.  
12.Replace logs.  
13.Replace glass and stove front.  
Follow lighting instructions on Page 25. Check flame  
color appearance. NOTE: Allow stove to burn for at  
least 1/2 hour to establish full flame color.  
ST228  
Should color need further adjustment, repeat steps 1  
- 12 for air shutter adjustment.  
Fig. 42 Attach switch wires to valve.  
20007065  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
Thermostat Connection (optional)  
Engage steel tabs  
gehind the cast  
iron bosses  
Use only a thermostat rated for 500 millivolts.  
Check the table below for the appropriate gauge ther-  
mostat wire to use for the length of lead required in your  
installation.  
Thermostat  
Wire / Gauge  
Maximum Run  
20 feet  
20 - 40 feet  
up to 60 feet  
Control Door  
18  
16  
14  
Bottom tabs engage  
notch in the leg.  
1. Install the wall thermostat in the desired location and  
run the wires to the stove location. Terminate these  
leads with 1/4” female connectors.  
ST474  
Fig. 43 Install the front plate.  
2. Connect the thermostat wires to the valve. (Fig. 42)  
Install the Front Plate  
This completes assembly of the Stardance stove.  
Hold the front plate by the window bars and lift it into  
position, engaging the two steel tabs on the top corners  
behind the adjacent bosses in the side plates. (Fig. 43)  
Then seat the Front against the sides so the tabs at the  
bottom lip engage with the notches in the stove legs.  
When properly installed, the bottom of the Front Plate  
cannot be pulled away from the sides without also lifting  
it .  
20007065  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
Operation  
The Stardance is operated with the operable door front  
plate in place with the doors open or closed. To open  
the front doors, insert the handle into the door latch stub  
and turn it to the left and up. (Fig. 44) When not in use,  
the handle may be stored in the handle holder on the  
right side of the rear shroud. (Fig. 47)  
Clockwise  
to Open  
ST476  
Fig. 46 Pilot assembly location.  
Flame & Temperature Adjustment  
Counterclockwise  
to Close  
For stoves equipped with HI/LO valves, flame adjust-  
ment is accomplished by rotating the HI/LO adjustment  
knob located near the center of the gas control valve.  
(Fig. 47)  
ST621  
Fig. 44 To open the front doors, turn handle clockwise.  
Turn  
Handle  
Holder  
counterclockwise  
to decrease  
Turn clockwise  
to increase  
flame height  
flame height  
Fig. 47 Flame adjustment knob for Honeywell valve.  
ST624  
Flame Characteristics  
Fig. 45 When not in use, store handle in the handle holder.  
It is important to periodically perform a visual check  
of the pilot and the burner flames. Compare them to  
Figure 48. If any of the flames appear abnormal, call a  
service person.  
Your First Fire  
Read these instructions carefully and familiarize your-  
self with the burner controls. Locate the pilot assembly,  
Figure 46. Follow the lighting instructions on Page 24  
exactly.  
During the first fire, it is not unusual to smell some odor  
associated with new logs, paint and metal being heated.  
Odors should dissipate within an hour or so, however,  
you can open a window to provide fresh air to alleviate  
the condition.  
Pilot and Burner Inspection  
CO105c  
Each time you light your heater check that the pilot  
flame and burner flame patterns are as shown in Figure  
54. If flame patterns are incorrect, turn the heater off.  
Contact your dealer or a qualified gas technician for as-  
sistance. Do not operate the heater until the pilot flame  
is correct.  
Follow regular maintenance procedures as described  
on Page 33.  
Red Glow  
LG143  
Fig. 48 Correct pilot and burner flame patterns.  
20007065  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
Lighting and Operating Instructions  
FOR YOUR SAFETY READ BEFORE LIGHTING  
WARNING:If you do not follow these instructions exactly, a fire or explosion  
may result causing property damage, personal injury or loss of life.  
A. This heater has a pilot which must be lit manu-  
ally. When lighting the pilot follow these instruc-  
tions exactly.  
Follow the gas supplier’s instructions.  
If you cannot reach your gas supplier, call  
the Fire Department  
B. BEFORE LIGHTING smell all around the  
heater area for gas. Be sure to smell next to  
the floor because some gas is heavier than air  
and will settle on the floor.  
C. Use only your hand to push in or turn the gas  
control knob. Never use tools. If the knob will not  
push in or turn by hand, do not try to repair it, call a  
qualified service technician. Applying force or any  
attempted repair may result in a fire or explosion.  
D. Do not use this fireplace if any part has been under  
water. Immediately call a qualified service techni-  
cian to inspect the heater and to replace any part of  
the control system and any gas control which has  
been under water.  
WHAT TO DO IF YOU SMELL GAS  
Do not try to light any fireplace  
Do not touch any electric switch  
Do not use any phone in your building  
Immediately call your gas supplier from a  
neighbor’s phone.  
Lighting Instructions  
1. STOP! Read the safety information above.  
2. Turn off all electrical power to the fireplace.  
3. For MN/MP/TN/TP appliances ONLY, go on to  
Step 4. For RN/RP appliances turn the ON/OFF  
switch to “OFF” position or set thermostat to  
lowest level.  
10. Push the control knob all the way in and hold.  
Immediately light the pilot by repeatedly depress-  
ing the piezo spark ignitor until a flame appears.  
Continue to hold the control knob in for about one  
(1) minute after the pilot is lit. Release knob and it  
will pop back up. Pilot should remain lit. If it goes  
out, repeat steps 5 through 8.  
4. Open control access panel.  
5. Push in gas control knob slightly and turn clock-  
wise  
to “OFF”.  
3/8" - 1/2"  
OFF  
Honeywell  
Euro SIT  
SIT NOVA  
If knob does not pop up when released, stop  
and immediately call your service technician or  
gas supplier.  
6. Wait five (5) minutes to clear out any gas. Then  
smell for gas, including near the floor. If you  
smell gas, STOP! Follow “B” in the safety infor-  
mation above. If you do not smell gas, go to the  
next step.  
7. Remove glass door before lighting pilot. (See  
Glass Frame Removal section).  
8. Visibly locate pilot by the main burner.  
9. Turn knob on gas control counterclockwise  
to “PILOT”.  
If after several tries, the pilot will not stay lit,  
turn the gas control knob to “OFF” and call your  
service technician or gas supplier.  
11. Replace glass door.  
12. Turn gas control knob to “ON” position.  
13. For RN/RP appliances turn the ON/OFF switch to  
“ON” position or set thermostat to desired setting.  
14. Turn on all electrical power to the fireplace.  
To Turn Off Gas To Heater  
1. Turn the ON/OFF switch to Off position or set  
the thermostat to lowest setting.  
3. Open control access panel.  
4. Push in gas control knob slightly and turn clock-  
2. Turn off all electric power to the fireplace if  
service is to be performed.  
wise  
to “OFF”. Do not force.  
5. Close control access panel.  
20007065  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
Troubleshooting / Honeywell #8420 Gas Control System  
NOTE: Before troubleshooting the gas control system, be sure the external gas shutoff is in the “ON” position.  
WARNING: REMOVE THE GLASS PANEL BEFORE PERFORMING ANY GAS CONTROL SERVICE WORK.  
SYMPTOM  
POSSIBLE CAUSES  
CORRECTIVE ACTION  
Using a match, light pilot. If pilot lights, turn off pilot  
and push the ignitor button again. If pilot will not light,  
check gap at electrode and pilot - it should be 1/8” to  
have a strong spark.  
1. Spark ignitor will not A. Defective or misaligned elec-  
light  
trode at the pilot  
Push piezo ignitor button. Check for spark at elec-  
trode and pilot. If there is no spark at the pilot, and  
electrode wire is properly connected, replace ignitor.  
B. Defective ignitor (push button)  
Check pilot flame. It must impinge on the thermo-  
couple or thermopile. NOTE: This pilot burner as-  
sembly uses both a thermocouple and a thermopile.  
The thermocouple operates the pilot flame. Tighten  
the thermocouple. The thermopile operates the main  
valve (ON and OFF). Clean and/or adjust pilot for  
maximum flame impingement on thermocouple and  
thermopile.  
A. Defective pilot generator (ther-  
mocouple)  
2. Pilot will not stay lit  
after carefully fol-  
lowing the lighting  
instructions  
Turn valve knob to ‘Pilot’. Maintain flow to pilot; mil-  
livolt meter should read greater than 10mV. If the  
reading is okay and the pilot does not stay on, re-  
place the gas valve. NOTE: An interrupter block (not  
supplied) must be used to conduct this test.  
B. Defective automatic valve op-  
erator  
Check rocker switch and wires for proper connection.  
Use jumper wires across terminals at rocker switch.  
If burner lights, replace rocker switch. If okay, use  
jumper wires across rocker switch wires at the valve;  
if burner lights, wires are faulty or connections are  
bad.  
3. Pilot lights, no gas to A. Remote switch or wires defec-  
burner, valve knob  
ON, remote switch  
(rocker switch) ON  
tive  
B. Thermopile may not generate  
sufficient voltage  
1. Be sure wire connections from thermopile at gas  
valve terminals are tight and thermopile is fully  
inserted into pilot bracket.  
2. One of the rocker switch wires may be grounded.  
Remove rocker switch wires from valve terminals.  
If burner now stays lit, trace rocker switch wiring  
from ground. It may be grounded to the appliance  
or the gas supply line.  
3. Check the thermopile with a millivolt meter. Take  
reading at thermopile (“TP” and “TP/TH”) terminals  
of gas valve. Should read 325 millivolts minimum  
while holding valve knob depressed in PILOT po-  
sition and with rocker switch OFF. Replace faulty  
thermopile if reading is below specified minimum.  
Check burner orifices for debris, and remove.  
C. Plugged burner orifice  
Turn knob to ON, place rocker switch to ON, millivolt  
meter should read greater than 10 mV. If the read-  
ing is okay and the burner does not light, replace the  
valve.  
D. Defective automatic valve op-  
erator  
4. Frequent pilot out-  
age  
Clean and/or adjust pilot flame for maximum flame  
impingement on thermocouple and thermopile.  
A. Pilot flame may be too low or  
high, (blowing or lifting), caus-  
ing the pilot to drop out  
B. Possible blockage of the vent  
terminal  
Check the vent terminal for blockage.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
Instructions for RF Comfort Control Valve  
Shut Off Procedure  
The Comfort Control valve allows remote control of tem-  
perature, fan and flame appearance.  
If the manual switch is in the REMOTE position, the  
transmitter can shut off the main burner and fan. How-  
ever, the control is still on and a command from the  
transmitter can turn on the main burner or fan.  
NOTE: The antenna should hang in free air away form  
grounded metal.  
To shut off the system, turn the pilotstat knob clockwise  
to the OFF position. This action closes the main gas  
and safety valves. The transmitter cannot turn on the  
main burner or fan.  
Operation  
1. If the manual switch is in remote position, switch it to  
LOCAL. (Fig. 49)  
2. Turn the pilotstat knob counterclockwise from OFF to  
the PILOT position, push the knob down, and hold in  
position. The pilot valve opens and allows gas to flow  
to the pilot burner.  
Transmitter Operation  
Off Mode  
In the OFF mode, the fireplace flame and fan are  
off, the display will show OFF and displays the room  
temperature. If the receiver is in REMOTE mode, the  
fireplace will shut off.  
3. Push plunger on the piezo until the pilot burner is lit.  
When the pilot burner is lit, the LED on the control  
will come on after approximately 40 seconds and  
will provide 1 short blink continuously in the normal  
mode. When the light turns off which will be approxi-  
mately 10 seconds after it has been continuously  
red, the receiver/valve is fully powered.  
Display  
Room Temperature  
Set Temperature  
Flame Height Level  
Fan Speed Level  
Mode  
Countdown Timer  
Low Battery  
Auto  
On  
Off  
Motor Top Cap  
Piezo Ignitor  
Flame  
Up  
Countdown  
Timer  
Increase Flame Height,  
Fan Speed Timer, or  
Set Point  
OFF  
Down  
Decrease Flame, Fan  
Speed Timer or Set  
Point  
Fan  
FP1039  
Fig. 50 Transmitter diagram.  
LED  
Local/Remote  
Switch  
Pilotstat  
Knob  
On (Manual) Mode  
Plug  
Antenna  
FP1037  
In the ON mode, the room temperature, flame and fan  
levels will be shown. MANUAL will appear next to both  
the flame and fan icons.  
Fig. 49 Comfort control valve.  
4. Release the knob. The shaft will move upward. The  
pilot burner should now stay burning. If the pilot  
burner goes out, repeat step 2.  
When the control is in the ON mode, the flame and fan  
levels, and delay timer are changed with the up and  
down buttons. To change the flame level, press the  
flame button followed by an arrow key. To change the  
fan level, press the fan key followed by an arrow key.  
Pushing the arrow key once will change the level by  
one unit.  
5. Turn the knob counterclockwise to the ON position. If  
the manual switch is in the LOCAL position, the main  
burner will turn on immediately.  
6. ON the initial use of a transmitter, a recognition  
operation is required between the receiver/valve and  
transmitter. Change the switch from LOCAL to RE-  
MOTE. Press the fan or flame button on the transmit-  
ter within 30 seconds. The LED will blink indicating  
the transmitter will now work with the receiver/valve.  
If the switch continues in the REMOTE position, the  
transmitter will now control the main valve, flame  
modulation level and fan control.  
Delay Timer Mode  
The shut off delay timer has a maximum of 2 hours and  
a minimum of zero minutes. To change the timer level,  
press the time key followed by an arrow key. Pushing  
the key once will change the timer by 10 minutes.  
7. If the manual switch is in the LOCAL position, the  
valve will be at the highest fixed pressure setting and  
the fan will be at the highest fixed speed. The trans-  
mitter will control the fan only.  
20007065  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
Auto Mode  
Pilot  
In the AUTO mode, the room temperature, set tem-  
perature, flame and fan levels will be shown. AUTO will  
appear next to both the flame and fan icons.  
Assembly  
Fan  
When the control is in the AUTO mode, the main burner  
will turn on/off or modulate based on the heat needed  
to maintain the set temperature. The flame level will  
change automatically to optimize the heat output  
needed to maintain the set temperature. To change the  
set temperature, press the up or down key. Pushing a  
key once will change the temperature by one degree.  
N A F  
Red  
White  
Red  
White  
In the AUTO mode, the fan speed will increase with  
increasing flame height or decrease with decreasing  
flame height. “AUTO” is displayed next to the flame and  
fan icons.  
White Dots  
Antenna  
Fan Override During Auto Mode  
Valve  
FP1038  
(Bottom View)  
If a lower or higher fan speed is desired when operating  
in the AUTO mode, the fan speed can be overridden by  
pushing the fan button followed by the up or down key.  
Pushing a key once will change the fan level by one  
unit. In this mode “AUTO” is displayed next to the flame  
icon and “MANUAL” is displayed next to the fan icon.  
Fig. 51 Comfort valve wiring diagram.  
5. In the event of multiple failure codes, next failure  
code follows previous failure code by approximately  
3 seconds.  
If an Error Code 3 is observed while performing the  
testing, complete the following:  
1. Make sure the spade connectors are pushed all the  
way on. If rhe Error Code 3 is still showing, then go  
to the next step.  
2. Switch the front two thermopile leads with the back  
two. Be sure the white lead is connected to the  
spade with the white dot next to it. If the Error Code  
3 is still showing, replace the thermopiles.  
If an Error Code 8 is observed while performing the  
testing, complete the following:  
Change Between F/C Temperature Units  
Push the up and down arrow keys simultaneously for  
at least 3 seconds to toggle between Fahrenheit and  
Celsius units.  
Disable Thermostat Function  
To disable the thermostat function in the AUTO mode,  
push the time and down keys simultaneously for at least  
3 seconds.  
1. Confirm the valve is not in REMOTE mode.  
• If the valve is producing Error Code 8 and in RE-  
MOTE mode, the valve is defective and should be  
replaced.  
• If the valve is in LOCAL mode and producing Error  
Code 8, then go to the next step.  
2. Slide the Remote/Local switch to REMOTE and  
teach the valve a transmitter (see item 6, page 32).  
The Error Code will clear itself after approximately  
1.5 minutes and return to normal operation.  
To Change Batteries  
1. Remove cover on the backside of the transmitter.  
Install 3 AAA batteries as shown and reattach cover.  
2. Once steps 1-3 in OPERATION are completed,  
receiver/valve and transmitter are now ready. Press  
any button on transmitter for recognition process to  
occur between the receiver/valve and transmitter.  
3. Use functions as described in TRANSMITTER sec-  
tion.  
LED Count  
Service Action  
Replace valve  
Confirm stepper motor connection exists  
Confirm fan connection exists and works  
Confirm gas type; jumper in place  
Replace thermopiles  
Troubleshooting  
8
7
5
4
3
2
1. Locate LED light on valve.  
2. LED will blink after every valid command received by  
the transmitter; this is not an error.  
3. Failure codes may occur anytime after pilot burner is  
lit.  
Turn fan ON  
4. Sequence is failure code followed by light not blink-  
ing for 30 seconds.  
NOTE: Some keys are not active.  
20007065  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
Comfort Valve System Control Sequence of Operation with Transmitter  
Set manual switch  
to local or remote  
five minute wait  
period  
Light pilot burner  
Did the LED stop  
blinking?  
Review LED  
failure analysis  
Release pilotstat  
knob  
Yes  
Cycle switch once  
and leave in remote.  
Pressy any key on  
transmitter for  
Choose Manual or  
Remote path. Set  
switch to manual or  
remote.  
Turn pilotstat knob  
from PILOT to ON  
recognition operation  
On Path  
Local Path  
Move switch from  
If manual switch is  
If the manual switch  
local to remote.  
Press any key on  
transmitter. Move  
switch back to  
local.  
Move switch from  
set to LOCAL, did  
main burner light and  
fan turn on?  
is set to REMOTE,  
press the mode but-  
ton to display “ON”.  
Does transmitter con-  
trol the main burner  
and fan?  
manual to remote.  
Press any key on  
transmitter.  
Yes  
Turn pilotstat knob  
to PILOT to turn off  
main burner.  
Yes  
Does transmitter  
No  
change levels of flame  
height, fan speed?  
Turn pilotstat knob  
to OFF to turn valve  
completely off.  
Set levels of flame  
height and fan to “0:  
to shut off main burner  
and fan.  
Turn pilotstat knob  
to OFF to turn valve  
completely off.  
20007065  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
Auto Path  
If the manual switch is set  
to REMOTE, press the  
mode button to display  
AUTO on the transmitter.  
Does the transmitter dis-  
play the room and tempera-  
ture setting?  
Move switch from  
LOCAL to REMOTE.  
Press any key within  
30 seconds.  
If the setting is above  
room temperature on the  
transmitter, does the main  
valve and fan turn on?  
No  
No  
If the settings is below  
room temperature on the  
transmitter, does the main  
valve and fan turn off?  
Turn pilotstat knob to OFF  
to turn valve completely  
off.  
20007065  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
Fuel Conversion Instructions  
WARNING! This conversion kit shall be installed  
by a qualified service agency in accordance with  
the manufacturer’s instructions and all applicable  
codes and requirements of the authority having  
jurisdiction. If the information in these instruc-  
tions is not followed exactly, a fire, explosion  
or production of carbon monoxide may result  
causing property damage, personal injury or loss  
of life. The qualified service agency is respon-  
sible for the proper installation of this kit. The  
installation is not proper and complete until the  
operation of the converted appliance is checked  
as specified in the manufacturer’s instructions  
supplied with the kit.  
Remove Screws  
Rear Log Bracket  
Pilot  
Left & Right Log  
Bracket Assembly  
ST350  
Fig. 53 Remove the rear log bracket and left and right log  
bracket assembly.  
CAUTION: The gas supply shall be shut off prior  
to disconnecting the electrical power, before pro-  
ceeding with the conversion.  
8. Remove injector orifices from left burner leg using  
1/2” wrench. (Fig. 60)  
9. Install conversion orifices. (Refer to Table 2)  
Models 3900, 3910 (R Models) Only  
Honeywell Valve  
10. Remove cap from Hi-Lo knob. This can be accom-  
plished by lifting the plastic cap off the screw. (Fig.  
54)  
OFF  
11. Remove the screw from center of Hi-Lo knob with  
small screwdriver turning counterclockwise. (Fig. 54)  
Cap  
Main Gas  
Line  
Gas Supply Inlet  
ST226  
Lift Open  
Fig. 52 Attach the gas line to the left side of the valve.  
Conversion Precautions  
Before proceeding, turn control knob on valve to OFF  
and turn gas supply OFF. Turn OFF any electricity that  
may be going to the appliance.  
Hi/Lo  
Knob  
Center Screw  
CO100  
Fig. 54 Remove center screw from Hi/Lo knob.  
Conversion Procedure  
12.Insert blue painted screw when converting to natural  
gas and red painted screw when converting to LP.  
1. Remove stove front. Lift stove front up and then  
swing bottom out and away to disengage from the  
stove body. (Page 33, Fig. 63)  
13. Tighten screw (do not over tighten), replace cap.  
SIT 820 Valve  
2. Swing open the swiveling latches at the top left and  
right corners of the glass frame. (Page 34, Fig. 64)  
14. Using TORX T20 bit, remove and discard the three  
(3) pressure regulator mounting screws (A), pressure  
regulator tower (B) and the spring and diaphragm  
assembly (C). (Fig. 55)  
3. Pull the top edge of the glass and frame assembly  
away from the firebox face. Place the assembly out  
of the way on a flat, padded surface such as a coun-  
ter protected by a towel.  
15. Insure the rubber gasket (D) is properly positioned  
and install the new HI/LO pressure regulator assem-  
bly to the valve using the new screws (E) supplied  
with the kit. Tighten the screws securely. (Ref. torque  
= 25 in/lb) (Fig. 56)  
4. Remove the logset from the firebox.  
5. Remove the rear log bracket by unfastening the  
screw. (Fig. 53)  
6. Remove the right and left log bracket assembly by  
unfastening the two screws which hold the burner in  
place. (Fig. 53)  
16. Install the enclosed conversion label (F) to the valve  
body where it can easily be seen. (Fig. 57)  
7. Hold the burner at the right hand side and lift to clear  
the right burner leg. Then pull to the right to clear the  
injectors on the left hand side.  
20007065  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
A
Pilot Hood  
B
C
Pilot  
Bracket  
CO105a  
Fig. 57 Remove pilot hood.  
O
Index Tab  
Snap Ring  
Allen Wrench  
FC107  
Fig. 55 Remove mounting screws, pressure regulator tower  
and spring and diaphragm assembly.  
CO106a  
E
Fig. 58 Remove pilot orifice.  
Pilot type 2  
• Loosen pilot hood turning counterclockwise using a  
7/16” wrench. (Fig. 59) NOTE: You may use pen-  
etrating oil to prevent pilot hood threads from seizing  
up.  
O
• Remove pilot orifice with needlenose pliers. (Fig.  
60) NOTE: Use a wrench to hold pilot tube in place  
while removing the orifice.  
D
• Install the conversion orifice.  
• Reinstall pilot hood and tighten until mark on pilot  
hood aligns with mark on pilot bracket.  
F
NOTE: Be sure burner leg remains at a 90° angle to  
firebox base after conversion.  
FC108  
Fig. 56 Replace regulator.  
Pilot Orifice Conversion  
1. Locate pilot. (Fig. 53)  
2. Replace pilot orifice.  
Pilot Type 1  
Pilot  
Index  
Marks  
• Remove pilot hood by lifting up. (Fig. 57) Do not  
remove snap ring to remove pilot hood. NOTE: It is  
not necessary to remove the pilot tube for conver-  
sion.  
Pilot Bracket  
CO105  
Fig. 59 Remove pilot hood. (Your pilot may have a different  
appearance.)  
• Remove pilot orifice with Allen wrench. (Fig. 58)  
• Install the conversion orifice.  
• Reinstall pilot hood. Be sure to align hood with  
index tab.  
Pilot Orfice  
CO106b  
Fig. 60 Remove pilot orifice.  
20007065  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
Models 3940, 3950 (RF Models) Only  
All Models  
16. Follow procedure for pilot type 2 to replace pilot  
orifice.  
21. Replace burner. Slide the burner in at an angle  
with left side lower than the right side. Slide the left  
side onto the injectors, making sure the burner leg  
remains at a 90° angle to the base. Lower the right  
hand side down in to place. Make sure the burner is  
as far left as possible and the injector shoulders are  
inside the burner.  
17. Remove and replace plug on lower right hand side  
of the valve; Red for LP and Blue for NG. (Page 26,  
Fig. 49)  
18. Remove motor top cap. Depress and turn center  
plunger until arrow points to correct screw. Red for  
LP and Blue for NG. NOTE: Plunger will “snap” into  
NG position when arrow is close to blue screw. It will  
not “snap” at LP (Red) position. (Fig. 61)  
NOTE: It is very critical to keep the left burner leg,  
which holds the injectors, at a 90° angle to the base.  
(Fig. 62) This keeps the orifices aligned with the  
tubes inside burner. Failure to do so could affect the  
flame appearance and performance of the unit.  
19. Insure manifold pressure remains between 3.2”  
- 3.5” w.c. for NG and 9,5” - 10” w.c. for LP. To adjust  
the manifold pressure, for NG, using a torque #10  
key turn the blue screw clockwise to increase the  
manifold pressure. Turn the screw counterclockwise  
to decrease the pressure. Use the red screw to  
adjust LP.  
22.Place conversion label on valve.  
23.Reinstall the right and left log bracket assembly.  
24.Reinstall the rear log bracket.  
25.Replace logs.  
26.Replace glass and stove front.  
Conversion is complete.  
20. Replace motor top cap.  
Motor Top Cap  
Center  
Plunger  
Left Burner Leg  
Valve  
Injector Orifice  
Blue - NG  
Red - LP  
90°  
FP1037b  
Fig. 61 Depress and turn center plunger.  
ST353a  
Fig. 62 Remove and replace injector orifices.  
Table 2. Injector Orifice Size Matrix  
Conversion to Natural Gas  
Input (Btu/h)  
Kit #  
Front  
Part #  
Rear  
Part #  
Minimum  
Maximum  
000-5021  
000-5011  
#54 / .055”  
30000514  
#44 / .086”  
30000334  
19,000  
28,000  
Conversion to LP  
Input (Btu/h)  
Kit #  
Front  
Part #  
Rear  
Part #  
Minimum  
Maximum  
000-5022  
000-5012  
#69 / .029”  
30000513  
#54 / .055”  
30000514  
20,000  
28,000  
20007065  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
Maintenance  
Your Stardance Gas Heater will provide years of service  
with minimal upkeep. The following procedures will help  
ensure that your stove continues to function properly.  
CAUTION  
TURN THE PILOT OFF BEFORE PAINTING. AL-  
LOW THE HEATER TO COOL COMPLETELY BE-  
FORE PAINTING.  
Annual System Inspection  
Have the entire heater and venting system inspected  
annually by a qualified gas technician. Replace any  
worn or broken parts.  
Cleaning the Glass  
WARNING: Allow the glass cool completely before  
attempting to clean.  
Logset and Burner /  
Cleaning and Inspection  
It will be necessary to clean the glass periodically. Dur-  
ing start-up, condensation, which is normal, forms on  
the inside of the glass and causes lint, dust and other  
airborne particles to cling to the glass surface. Also  
initial paint curing may deposit a slight film on the glass.  
It is therefore recommended that the glass be cleaned  
two or three times with a non-ammonia household  
cleaner and warm water (we recommend gas fireplace  
glass cleaner). After that the glass should be cleaned  
two or three times during each heating season depend-  
ing on the circumstances present.  
Cleanliness is critical to the proper function of the  
heater. The logset and burner must all be kept free of  
dust and unobstructed by debris. Inspect these areas  
before each use and clean as necessary.  
1. Turn the burner OFF and let the heater cool com-  
pletely before cleaning.  
2. Lift the Stove Front up and then swing the bottom  
out to disengage it from the heater shell. (Fig. 64)  
3. Carefully remove the glass and frame assembly and  
place it out of the way on a flat, padded surface such  
as a counter protected by a towel.  
Clean glass after first two weeks of opera-  
tion.  
4. Carefully inspect the Logs for damage. Contact your  
local dealer if any damage is evident. DO NOT OP-  
ERATE THE HEATER WITH DAMAGED LOGS.  
Glass Replacement  
Replace glass only with CFM Corporation approved  
parts. Refer to Page 36 for Replacement Parts. Refer to  
Figure 63 and previous instructions for removal of the  
damaged glass frame.  
5. Use a soft bristled brush to sweep dust or debris  
from the Logs, Pilot and Burner. Use care as the logs  
are fragile and susceptible to damage. DO NOT USE  
A VACUUM TO CLEAN THE LOGS OR BURNER.  
6. Replace the glass panel and frame assembly.  
7. Replace the Stove Front.  
Care of Cast Iron  
An occasional dusting with a dry rag will help keep the  
painted surfaces looking new. Use high-temperature  
stove paints, available through your local dealer, to  
touch-up areas as needed. Clean areas to be painted  
with a wire brush and be sure to cover the logs, burner  
and valve assembly, glass and frame assembly. Apply  
the paint sparingly; two light coats of paint will give bet-  
ter results than a single heavy coat.  
Clean porcelain enamel surfaces with a soft, damp  
cloth. Do not use abrasive cleaning agents. If neces-  
sary, use only a cleaning agent formulated especially  
for use on porcelain enamel surfaces.  
ST474a  
Fig. 63 Remove the stove front.  
20007065  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
Inspect the Vent System Annually  
Have the vent system inspected annually by a qualified  
technician. Shut off the main gas supply before inspect-  
ing the system. Both the inner exhaust pipe and the out-  
er combustion supply pipe must be checked to confirm  
that they are unblocked and in good condition.  
ST208  
Fig. 64 Release the latches to release the glass frame.  
Check the Gas Flame Regularly  
To ensure that the stove is operating properly, check the  
flames periodically to confirm that they match Figure 64.  
The flames will be blue during the first 15-20 minutes of  
operation, and will gradually turn to yellow after that.  
Gasket Replacement  
The Stardance Gas Heater uses a ‘tadpole’ type gasket  
to seal between the glass panel and the frame. In time,  
this gasket can become brittle and compressed and  
should be replaced. New gasket is available from your  
dealer.  
Do not use your stove if the flame pattern differs from  
that shown here. Contact your Vermont Castings dealer  
or a qualified technician for help.  
Shut off the gas supply and allow the stove to cool.  
Wear safety goggles and a dust mask.  
1. Remove the Front, Glass Frame and Glass Panel.  
(Figs. 63 & 64) Remove the old gasket. Use a  
razor blade to separate the glass and gasket from  
the frame, and to clean the glass of any remaining  
cement or bits of gasket. Use a cold chisel if neces-  
sary.  
Red  
Glow  
2. Determine the correct length of gasket by laying it  
out around the edge of the glass. Allow an extra 1  
- 2” (25-50mm). Mark the spot to be cut. Use a utility  
knife.  
LG143  
Fig. 66 Correct flame pattern.  
3. Starting on a long edge, remove about 6” of the pro-  
tective paper strip and apply the flat adhesive face  
of the gasket around the outside-facing edge of the  
panel. Continue around the panel, applying a bout 6”  
at a time and being careful to not stretch the mate-  
rial. Do not overlap the gasket ends. (Fig. 65)  
Stove Disassembly  
If there is ever a need to remove the firebox assem-  
bly from the stove shell, support the firebox with solid  
stands about 6” (152mm) tall under the left and right  
outer edges of the firebox base. Do not set the firebox  
assembly directly on the floor; this can damage the  
control valve and/or the gas lines from the valve to the  
firebox.  
4. Apply a thin bead of high temperature silicone rubber  
sealant along the inside corner of the glass frame, all  
around the perimeter. Place the flat gasketed side of  
the glass panel back into the steel frame. Pinch the  
rounded inside-facing gasket material to bulk it up.  
Before removing the firebox from the shell, disconnect  
the on/off switch wires from the valve. If the assembly  
includes the optional fan, disconnect the fan rheostat.  
If the installation includes a wall thermostat, disconnect  
the thermostat leads from valve.  
5. Replace the glass frame and front panel as previ-  
ously described.  
Disconnection and reconnection to the gas line should  
only be done by a qualified gas service technician.  
Upon reinstallation, the vent system must be sealed to  
the firebox as shown in the installation section, Page  
14. Also be sure the logs are placed in the firebox cor-  
rectly, as shown in Page 19, Figures 34 & 35.  
ST179  
Fig. 65 Wrap the gasket material around the outside iedge of  
the glass.  
20007065  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
Wiring Diagrams  
ON  
OFF  
FAN  
POWER  
CORD  
On/Off Switch  
Wiring  
WHT  
BLK  
TP/TH  
TP  
TH  
Chassis  
Ground  
GRN  
Black  
ST124b  
BLK  
Thermostat  
(Optional)  
Optional Thermostat  
Wiring  
FAN JUNCTION BOX  
TP/TH  
Strain Relief  
TP  
TH  
ON / OFF  
Rheostat  
Black  
ST124c  
Fig. 67 On/Off switch and optional thermostat circuit.  
Snapstat  
NOTE: IF ANY OF THE ORIGINAL WIRE, AS  
SUPPLIED WITH THE APPLIANCE, MUST BE  
REPLACED, IT MUST BE REPLACED WITH TYPE  
SF-2, 200°C WIRE OR ITS EQUIVALENT.  
WHT  
BLK  
GRN  
RHEOSTAT / SNAPSTAT  
BOX  
Chassis Ground  
Safety Limit  
Switch  
ST153  
MOTOR  
Schematic Diagram  
BLK  
Valve  
SNAPSTAT  
WHT  
BLK  
ON/OFF  
RHEOSTAT  
ST665  
Fig. 68 Draft hood adapter wiring.  
ST234  
Fig. 69 Stardance fan circuit.  
20007065  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
6
5
4
2
7
1a  
3
11  
13  
12  
1c  
14  
10a  
1b  
18  
15  
OFF  
8a,b  
16  
17  
19  
10b  
9a,b  
10c  
OFF  
21  
20  
LED  
22  
23  
28  
29  
25a,b,  
c,d  
27  
32  
31  
35  
34  
30  
38  
24  
40  
39  
36  
33  
26  
41  
48a,b  
42  
49  
CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time,  
without notice.  
Stardance Direct Vent/Natural Vent Gas Heater (SDV30)  
Models 3900-3916, 3940-3956  
Ref. Description  
SDV30  
1. Gas Log Assembly - SDV30  
1a. Log Rear (V21)  
1b. Log Right (V22)  
1c. Log Left (V23)  
20003458  
20003459  
20003460  
20003461  
20007065  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
Stardance Direct Vent/Natural Vent Gas Heater (SDV30)  
Models 3900-3916, 3940-3956 (continued)  
Ref. Description  
SDV30  
2. Gasket Cement  
3. Manifold Assembly  
1206122  
20003739  
4. Lava Rocks Burner  
57897  
5. Gasket, Glass - Med. Knit - RDV40  
6. Glass, DV25  
1203702  
1601691  
7. Glass Frame Assembly - SDV30  
8a. Valve RN Honeywell VS8420E 2038 (Serial #’s up to 8738)*  
8b. Valve RP Honeywell VS8420E 2020 (Serial #’s up to 8738)**  
9a. Valve Gas Honeywell Convertible RFN RV8310E  
9b. Valve Gas Honeywell Convertible RFP RV8310E  
10a. Pilot Assembly 3Way N/DV RN 0.199.706  
Pilot Assembly 3Way N/DV RP 0.199.703  
10b. Pilot, PSE - NA175  
30000127  
10001782  
10001759  
20003719  
20003720  
10002264  
10002265  
20001115  
Pilot, PSE - LP175  
20001116  
10c. Pilot Assembly 3Way DV/RFN CS3003A2009  
Pilot Assembly 3Way DV/RFP CS3003A2017  
11. Thermocouple 24”  
20002266  
20002268  
53373  
7531137  
12. Electrode Ignitor w/Cable SIT24  
13. Pilot Top Convertible  
10001297  
10002266  
14. Thermopile 18” RS  
51827  
7533113  
15. Nut Electrode SIT #0.974.144  
16. Tubing Pilot w/Fittings 1/8 x 24”  
17. Thermopile - PSE for RF Pilots  
18. Burner Housing Assembly NG/LP  
19. Switch ON/OFF - RN/RP Models  
20. Grate, Burner - JDV  
57886  
10001296  
20002400  
20002214  
30000874  
20002167  
21. Wiring Harness - FSDV32 RN/JDV  
22. Right Log Bracket  
10002582  
20005259  
23. Left Log Bracket  
20005258  
24. Door, Control - FS/HM  
1301087  
25a. Orifice Hood #69 - Front - LP  
25b. Orifice Hood #54 - Front - NG  
25c. Orifice Hood #54 - Rear - LP  
25d. Orifice Hood #44 - Rear - NG  
26. Top, Stardance DV  
27. Nut, Hex Jam 3/8 -16 TOPLK-Z  
28. Pawl Assy, Ash Door - ENC  
29. Front Steel Handle/Shaft - NI/VER  
30. Handle Pkg, Ceramic w/Screw  
31. Gasket, Base Pan - JDV  
30000513  
20000130  
20000130  
30000334  
Refer to Enamel Parts Chart Page 38  
1203290  
5004025  
30002717  
0004345  
20002282  
32. Gasket, Base Pan Inner  
20002566  
33. Front, Stardance OP Dr  
Refer to Enamel Parts Chart Page 38  
*When converting to SIT valve, must order RP275  
**When converting to SIT valve, must order RP269  
20007065  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
Stardance Direct Vent/Natural Vent Gas Heater (SDV30)  
Models 3900-3916, 3940-3956 (continued)  
Ref. Description  
SDV30  
34. Door, Right - Stardance  
Refer to Enamel Parts Chart Page 38  
35. Door, Left - Stardance  
Refer to Enamel Parts Chart Page 38  
36. Sensor 1450 CMG-8184-0032  
37. Draft Hood Final Assembly (not shown)  
38. Gasket, HE Door  
10002013  
20005228  
1203687  
39. Left End  
Refer to Enamel Parts Chart Page 38  
40. Right End  
Refer to Enamel Parts Chart Page 38  
41. Transmitter Honeywell RF  
42. FK26 Fan Subassembly (RF only)  
43. Switch Bracket (not shown)  
44. Starter Pipe (not shown)  
45. Rear Shroud (not shown)  
46. 2¹⁄₄” Restrictor (not shown)  
47. 1/4” Fiberglass Gasket  
48a. Valve Nova SIT820.662 RN (Serial #’s starting with 8738)  
48b. Valve Nova SIT820.653 RP (Serial #”s starting with 8738)  
49. Ignitor Piezo w/Nut SIT  
20002047  
30000879  
53821  
30000245  
20003802  
1409170  
1203560  
20010563  
20010645  
52464  
50. Bracket Piezo Ignitor (not shown)  
20010876  
Fuel Conversion Kits  
Conversion Kit, NG to LP - JDV/SDV30R  
Conversion Kit, NG to LP - SDV30RFN (DB)  
Conversion Kit, LP to NG - JDV/SDV30R  
Conversion Kit, LP to NG - SDV30RFP (DB)  
Kit #000-5022  
Kit #000-5012  
Kit #000-5021  
Kit #000-5011  
Shell Enamel Part Numbers  
Color  
Classic  
Top  
Left End  
30001280  
30003300  
30001287  
30003308  
30001308  
30001294  
30001321  
30001301  
30002547  
Right End  
30001279  
30003301  
30001286  
30003309  
30001307  
30001293  
30001320  
30001300  
30002548  
Front OP  
30001496  
30003302  
30001261  
30003310  
30001270  
30001264  
30001314  
30001267  
30002550  
Left Door  
30001139  
30003304  
30001263  
30003312  
30001272  
30001266  
30001316  
30001269  
30002552  
Right Door  
30001138  
30003303  
30001262  
30003311  
30001271  
30001265  
30001315  
30001268  
30002551  
30001276  
30003305  
30001283  
Biscuit  
Bordeaux  
Chestnut Brown 30003313  
Ebony  
30001304  
30001290  
30001317  
30001297  
30002549  
Forest Green  
Midnight Blue  
Sand  
Suede Brown  
Vermont  
Classic Green  
30003321  
30003316  
30003317  
30003318  
30003320  
30003319  
20007065  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
Optional Accessories  
Fan Kits  
Screen Kit  
FK26 Fan  
An optional screen, S30SK, for use with the operable  
doors is available to allow the doors to be left in the  
open position.  
The FK26 fan helps distribute heated air from within  
the firebox out into the room. The fan is controlled by a  
snapstat that turns power on and off as the firebox tem-  
perature rises above and falls below a preset tempera-  
ture. A rheostat provides for variable fan speeds.  
Warming Shelf  
Warming shelves add versatility to your stove; they can  
be used to keep foods warm at mealtime.  
Specifications  
Model  
Color  
115 Volt / 60Hz / .75 Amps  
Maintenance  
2702  
2684  
2685  
2688  
2704  
2706  
2764  
2765  
2711  
2712  
Classic Black  
Biscuit  
Chestnut Brown  
Vt. Classic Green  
Bordeaux  
Forest Green  
Sand  
Ebony  
The fan itself does not require regular maintenance,  
however, periodic cleaning of the fan and the surround-  
ing area is required.  
Installation  
Refer to Page 13 for installation instructions.  
Remote Controls  
Midnight Blue  
Suede Brown  
The remote control allows you to turn the heater on or  
off from anywhere in the room. Refer to Page 40 for wir-  
ing diagrams. These remotes for use with RN/RP model  
gas stoves.  
The shelf installation is done in three stages. First you  
attach the shelf loosely to the stove, leaving the screws  
loose enough to allow final adjustments. Then, you po-  
sition the shelf and adjust the brackets so the shelf fits  
correctly. Finally, you tighten the screws.  
Model  
Functions Controlled  
RC1  
RC2  
IMTFK  
ON/OFF  
ON/OFF and Temperature  
Wall mounted thermostat control  
Refer to the instructions included with each warming  
shelf for complete installation procedures.  
Decorative Rings  
7” brass or charcoal gray rings are available to add a  
decorative touch to the exposed stove pipe.  
Model  
Description  
7FSDRG/4  
7FSDRP/4  
7” Charcoal Gray Rings (4)  
7” Polished Brass Rings (4)  
20007065  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
20007065  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stardance Direct Vent/Natural Vent Gas Heater  
20007065  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LIMITED LIFETIME WARRANTY  
PRODUCT COVERED BY THIS WARRANTY  
All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic brand gas fireplaces equipped with  
an Insta-Flame Ceramic Burner, or standard steel tube burner.  
BASIC WARRANTY  
Any part and/or component replaced under the provisions of this  
warranty is covered for six months or the remainder of the original  
warranty, whichever is longest.  
CFM Corporation (hereinafter referred to collectively as the Company)  
warrants that your new Vermont Castings or Majestic Gas Fireplace/  
Stove is free from manufacturing and material defects for a period of  
one year from the date of purchase, subject to the following conditions  
and limitations.  
This warranty is limited to the repair of or replacement of part(s) found  
to be defective in material or workmanship, provided that such part(s)  
have been subjected to normal conditions of use and service, after  
said defect is confirmed by the Company’s inspection.  
EXTENDED LIFETIME WARRANTY  
The company may, at its discretion, fully discharge all obligations  
with respect to this warranty by refunding the wholesale price of the  
defective part(s)  
The heat exchanger, where applicable, and combustion chamber  
of every Vermont Castings or Majestic gas product is warranted for  
life against through wall perforation. All appliances equipped with an  
Insta-Flame Ceramic Burner have limited lifetime coverage on the  
ceramic burner plaque. Warrantees are made to the original owner  
subject to proof of purchase and the conditions and limitations listed  
on this Warranty Document  
Any installation, labor, construction, transportation, or other related  
costs/expenses arising from defective part(s), repair, replacement,  
or otherwise of same, will not be covered by this warranty, nor shall  
the Company assume responsibility for same. Further, the Company  
will not be responsible for any incidental, indirect, or consequential  
damages except as provided by law.  
COMPONENT WARRANTY  
CAST IRON: All external and internal cast iron parts are warranted for a  
period of three years.  
SOME STATES DO NOT ALLOW FOR THE EXCLUSION OR  
LIMITATIONS OF INCIDENTALAND CONSEQUENTIAL DAMAGES  
OR LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY  
LASTS, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOUR  
CIRCUMSTANCES. THIS WARRANTY GIVES YOU SPECIFIC  
RIGHTSANDYOU MAYHAVE OTHER RIGHTS WHICH VARYFROM  
STATE TO STATE.  
Note: On porcelain enamel finished external parts and accessories  
The Company offers no Warranty on chipping of enamel surfaces.  
Inspect all product prior to accepting it for any damage to the  
enamel.  
The salt air environment of coastal areas or a high humidity  
environment can be corrosive to the porcelain enamel finish. These  
conditions can cause rusting of the cast iron beneath the porcelain  
enamel finish, which will cause the finish to flake off.  
All other warranties-expressed or implied- with respect to the product,  
its components and accessories, or any obligations/liabilities on the  
part of the Company are hereby expressly excluded.  
The Company neither assumes, nor authorizes any third party to  
assume on its behalf, any other liabilities with respect to the sale of  
this Vermont Castings or Majestic product  
Dye lot variations with replacement parts and/or accessories can  
occur and are not covered by warranty.  
GLASS DOORS: Glass doors are covered for a period of one year.  
Glass doors are not warranted for breakage due to misuse or accident.  
Glass doors are not covered for discoloration or burned in stains due to  
environmental issues, or improper cleaning and maintenance.  
The warranties as outlined within this document do not apply to  
chimney components or other non CFM Corporation accessories used  
in conjunction with the installation of this product..  
Damage to the unit while in transit is not covered by this warranty but  
is subject to claim against the common carrier. Contact the dealer  
from whom you purchased your fireplace/stove (do not operate the  
appliance as this might negate the ability to process the claim with the  
carrier).  
BRASS PLATED PARTS AND ACCESSORIES: Brass parts should be  
cleaned with Lemon oil only. Brass cleaners cannot be used. Mortar  
mix and masonry cleaners may corrode the brass finish. The Company  
will not be responsible for, nor will it warrant any brass parts which are  
damaged by external chemicals or down draft conditions.  
The Company will not be responsible for:  
GAS VALVES: Gas valves are covered for a period of one year  
a) Down drafts or spillage caused by environmental conditions such  
as near-by trees, buildings, roof tops, hills, or mountains.  
b) Inadequate ventilation or negative air pressure caused by  
mechanical systems such as furnaces, fans, clothes dryers, etc.  
ELECTRONIC AND MECHANICAL COMPONENTS: Electronic and  
mechanical components of the burner assembly are covered for one  
year. All steel tube burners are warranted for one year.  
ACCESSORIES: Unless otherwise noted all components and CFM  
Corporation company supplied accessories are covered for a period of  
one year.  
This warranty is void if:  
a) The fireplace has been operated in atmospheres contaminated by  
chlorine, fluorine, or other damaging chemicals.  
b) The fireplace has been subjected to prolonged periods of  
dampness or condensation  
c) Any damages to the fireplace, combustion chamber, heat  
exchanger or other components due to water, or weather damage,  
which is the result of but not limited to, improper chimney/venting  
installation.  
CONDITIONS AND LIMITATIONS  
This new Vermont Castings or Majestic product must be installed by  
a competent, authorized, service contractor. A licensed technician, as  
prescribed by the local jurisdiction must perform any installation/service  
work. It must be installed and operated at all times in accordance with  
the Installation and Operating instructions furnished with the product.  
Any alteration, willful abuse, accident, or misuse of the product shall  
nullify this warranty.  
d) Any alteration, willful abuse, accident, or misuse of the product  
has occurred.  
This warranty is non-transferable, and is made to the original owner,  
provided that the purchase was made through an authorized supplier  
of the Company.  
IF WARRANTY SERVICE IS NEEDED…  
1) Contact your supplier. Make sure you have your warranty,  
your sales receipt, and the model/serial number of your  
CFM Corporation product.  
2) DO NOT ATTEMPT TO DO ANY SERVICE WORK  
YOURSELF.  
The customer must pay for anyAuthorized Dealer in-home travel fees  
or service charges for in-home repair work. It is the dealers option  
whether the repair work will be done in the customer’s home or in the  
dealer’s shop.  
If upon inspection, the damage is found to be the fault of the  
manufacturer, repairs will be authorized at no charge to the customer  
parts and/or labor.  
20007065  
42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GARANTIE À VIE LIMITÉE  
PRODUIT COUVERT PAR LA PRÉSENTE GARANTIE  
L’ensemble des cuisinières à gaz, des poêles encastrables et des foyers à gaz Vermont Castings, ainsi que l’ensem-  
ble des foyers à gaz de marque Majestic équipés d’un brûleur en céramique Insta-Flame ou d’un brûleur en acier  
du fabricant, les réparations, les pièces et la main-d’œuvre seront  
autorisées sans frais pour le client.  
standard.  
GARANTIE DE BASE  
Toute pièce et (ou) tout composant remplacé en vertu des dispo-  
La société CFM Corporation (ci-après la « Société ») garantit votre  
sitions de la présente garantie est couvert pour une période de six  
nouveau poêle/foyer au gaz Vermont Castings ou Majestic contre  
mois ou jusqu’à l’expiration de la garantie originale, selon la dernière  
tous défauts de fabrication et de matières premières pour une  
des éventualités à survenir.  
période d’un an à compter de la date d’achat, sous réserve des  
conditions et limitations suivantes.  
GARANTIE À VIE PROLONGÉE  
• Cette garantie est limitée à la réparation ou au remplacement  
de toute pièce trouvée défectueuse en matières premières ou  
main-d’oeuvre, à condition que ladite pièce ait été sujette aux con-  
L’échangeur de chaleur, s’il y a lieu, ainsi que la chambre à com-  
bustion de tout produit à gaz de la société Vermont Castings ou  
Majestic sont garantis pour la vie contre la perforation des parois.  
Tous les produits équipés d’un brûleur en céramique Insta-Flame  
comprennent une garantie à vie limitée de la plaque du brûleur en  
céramique. Les garanties sont accordées à l’acheteur d’origine,  
le tout sujet à une preuve d’achat et aux conditions et limitations  
suivantes :  
ditions normales d’usage et de service, après que ledit défaut a été  
confirmé par une inspection par la Société.  
• La Société peut, à sa discrétion, se décharger entièrement de toutes  
obligations se rapportant à cette garantie en remboursant le prix de  
gros de toute pièce défectueuse.  
Tous les frais/dépenses d’installation, de main-d’oeuvre, de cons-  
truction, de transport ou autres causés par toute pièce défectueuse,  
une réparation, un remplacement ou autre, ne seront pas couverts  
en vertu de la présente garantie, et la Société n’assume aucune  
responsabilité pour ceux-ci. De plus, la Société ne pourra être tenue  
responsable de tous dommages fortuits ou indirects, sauf là où prévu  
par la loi.  
• CERTAINS PROVINCES NE PERMETTENT PAS L’EXCLUSION  
OU LES LIMITATIONS RELATIVES AUX DOMMAGES CONSÉCU-  
TIFS OU INDIRECTS QUANT À LA DURÉE DE TOUTE GARANTIE  
IMPLICITE, SI BIEN QU’IL EST POSSIBLE QUE LES LIMITATIONS  
CI-DESSUS NE S’APPLIQUENT PAS DANS VOTRE CAS. LA PRÉ-  
SENTE GARANTIE VOUS DONNE DES DROITS SPÉCIFIQUES,  
ET IL EST POSSIBLE QUE VOUS AYEZ D’AUTRES DROITS QUI  
PEUVENT VARIER D’UN ÉTAT À L’AUTRE.  
GARANTIE DES COMPOSANTS  
FONTE : Toutes les pièces en fonte externes et internes sont garanties  
pour une période de trois ans.  
Nota : Dans le cas des pièces et accessoires externes au fini en émail  
de porcelaine, la Société n’offre aucune garantie quant à l’écaillage  
des surfaces en émail. Avant d’accepter un produit, inspectez-le afin  
de vous assurer que les surfaces en émail ne sont pas endomma-  
gées.  
L’atmosphère saline des zones côtières ou les environnements à  
forte humidité peuvent provoquer la corrosion du fini en émail de  
porcelaine. Ces conditions peuvent également faire rouiller la fonte  
sous le fini en émail de porcelaine, provoquant ainsi l’écaillement de  
la couche de fini.  
Dans le cas des pièces et (ou) des accessoires de remplacement,  
les variations de lots de teinture sont possibles, mais elles ne sont  
pas couvertes par la garantie.  
Toute autre garantie, expresse ou implicite, en ce qui a trait au pro-  
duit et ses composants et accessoires, ou toute obligation/responsa-  
bilité de la part de la Société sont expressément exclues en vertu des  
présentes.  
PORTES EN VERRE : Les portes en verre sont couvertes pour une  
période d’un an. Les portes en verre ne sont pas garanties contre le  
bris causé par un mauvais usage ou un accident. Les portes en verre  
ne sont pas couvertes contre la décoloration ni contre les taches  
imprégnées attribuables à des conditions environnementales ou à un  
nettoyage et un entretien inadéquats.  
PIÈCES ET ACCESSOIRES PLAQUÉS EN LAITON : Les pièces en  
laiton ne doivent être nettoyées qu’avec de l’essence de citron. Les  
nettoyants pour le laiton ne doivent pas être utilisés, et les agents net-  
toyants pour le mortier et la maçonnerie peuvent provoquer la corrosion  
du fini laiton. La Société ne pourra être tenue responsable des domma-  
ges à toute pièce en laiton occasionnés par des conditions chimiques  
externes ou le refoulement, et elle n’offre aucune garantie à cet égard.  
SOUPAPES À GAZ : Les soupapes à gaz sont couvertes pour une  
période d’un an.  
• La Société n’assume et n’autorise personne à assumer, en son nom,  
toute responsabilité en ce qui a trait à la vente de ce produit Vermont  
Castings ou Majestic.  
• Les garanties, telles qu’elles sont décrites dans le présent document,  
ne s’appliquent pas aux composants de cheminée ni à d’autres ac-  
cessoires CFM Corporation utilisés conjointement avec l’installation  
de ce produit.  
• Les dommages causés à l’unité tandis qu’elle est en transit ne sont  
pas couverts par la présente garantie, mais pourront être l’objet  
d’une réclamation contre le transporteur général. Communiquez avec  
le détaillant chez qui vous avez acheté votre foyer/poêle (n’utilisez  
pas l’appareil étant donné que cela pourrait annuler toute réclamation  
contre le transporteur).  
• La Société n’engagera aucune responsabilité quant :  
a) au refoulement de cheminée ou débordement causé par les  
conditions environnementales (arbres, édifices, toits, coteaux ou  
montagnes adjacents);  
COMPOSANTS ÉLECTRONIQUES ET MÉCANIQUES : Les compo-  
sants électroniques et mécaniques du brûleur sont couverts pendant un  
an. Tous les brûleurs en acier sont garantis pendant un an.  
ACCESSOIRES : À moins d’indication contraire, tous les composants  
et accessoires fournis par CFM Corporation sont couverts pendant une  
période d’un an.  
b) à une ventilation inadéquate ou une pression d’air négative  
causée par des systèmes mécaniques comme les fournaises, les  
ventilateurs, les sécheuses, etc.  
• Cette garantie est nulle si :  
a) le foyer a été utilisé dans une atmosphère contaminée par du  
chlore, du fluor ou tout autre produit chimique;  
b) le foyer est assujetti à de longues périodes d’humidité ou de  
condensation;  
c) des dommages sont causés au foyer, à la chambre de combus-  
tion, à l’échangeur de chaleur ou aux autres composants par de  
l’eau ou par la température qui est le résultat mais sans y être  
limité, d’une mauvaise installation de cheminée/ventilation;  
d) toute altération ainsi que tout abus volontaire, accident ou mau-  
vais usage du produit annule la présente garantie.  
CONDITIONS ET LIMITATIONS  
• Ce nouveau produit Vermont Castings ou Majestic doit être installé  
par un entrepreneur de service autorisé et compétent. L’installation/le  
service doivent être assurés par un technicien breveté, conformé-  
ment à la juridiction locale. Le produit doit être installé et utilisé en  
tout temps selon les instructions d’installation et de fonctionnement  
fournies avec le produit. Toute altération ou tout abus volontaire,  
accident ou mauvais usage du produit annulera cette garantie.  
• Cette garantie n’est pas transférable et est offerte à l’acheteur  
d’origine, à condition que l’achat ait été effectué par l’entremise d’un  
détaillant autorisé de la Société.  
SI UN SERVICE SOUS GARANTIE EST REQUIS…  
1) Communiquez avec votre détaillant. Assurez-vous que vous avez  
votre garantie, votre reçu de caisse ainsi que le numéro de modèle/  
série de votre produit CFM Corporation.  
• Le client doit assumer les frais de déplacement à domicile de tout  
détaillant autorisé ou les frais de service relatifs à toute réparation  
effectuée à domicile. Le détaillant peut à son choix effectuer les  
réparations chez le client ou à son atelier.  
2) NE TENTEZ PAS D’EFFECTUER DES RÉPARATIONS VOUS-  
MÊME.  
• Si, lors de l’inspection, on constate que les dommages sont la faute  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Efficiency Ratings  
Model  
EnerGuide Ratings  
Fireplace Efficiency (%)  
SDV30RN  
SDV30RP  
SDV30RFN  
SDV30RFP  
63.0  
63.0  
63.0  
63.0  
CFM Corporation  
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Targus Webcam AVC0102 User Manual
Toastmaster Blender TFP2 User Manual
Toastmaster Oven 389U User Manual
Toshiba Computer Monitor TR2006R User Manual
Toshiba Laptop U840W User Manual
Toshiba Network Card OIS120 User Manual
Tripp Lite Surge Protector ISOBAR6DBS User Manual
USRobotics Network Card Instant802 APSDK User Manual
Velodyne Acoustics Speaker HGS 10 User Manual
Wachsmuth Krogmann CRT Television TQ 10 User Manual