RETRO STYLE UNDER CABINET RANGEHOOD SPECIFICATIONS  
CLH9 Halogen lights only.  
9”  
2”  
½Offset  
CLH9  
Connection Diagram (30”- 48” Widths)  
Recommended  
Mounting Height*  
1 ¾”  
5 ¼”  
1 3⁄8”  
5 ½”  
5 ¼”  
Wall Side  
Wall Side  
Vent  
Holes  
Soffit  
Vent  
Hole  
1 ¾”  
Electrical  
Electrical  
8Outlet  
Cabinets  
6Outlet  
Centerline  
of Hood  
3 ¼”  
Centerline  
of Hood  
9”  
300 CFM B100 Single Blower  
(Top View)  
600 CFM B200 Dual Blower  
(Top View)  
24”-27”  
Connection Diagram (42” - 48”)  
10Round  
10Round  
7 516”  
7 516”  
1 ¾”  
5 ½”  
1 7⁄8”  
Wall Side  
36”  
Vent  
Holes  
17 ½”  
Electrical (2)  
6Outlet  
5 ¼”  
*Exceeding recommended  
mounting height may  
compromise performance.  
8Round  
8Round  
6Round  
Centerline  
of Hood  
8Outlet  
2”  
VP562 Transition (Optional) For B300  
(B200 Dual Blower & B100 Single Blower)  
900 CFM B200 Dual & B100 Single Blower  
(Top View)  
10OR 12”  
Round  
Connection Diagram (48”)  
11”  
5 ½”  
11”  
12Round  
12Round  
5 ½”  
Wall Side  
Vent  
Holes  
16 ½”  
1 ¾”  
8Outlet  
5 ¼”  
Electrical (2)  
VP562/VP563  
transition  
8Outlet  
Centerline  
of Hood  
8Round  
8Round  
8Round  
3”  
centers outlet  
over top of hood  
VP563 Transition (Optional) For B400  
(Double B200 Dual Blowers)  
1200 CFM Double B200 Dual Blowers  
(Top View)  
Electrical/Mechanical Specifications For Blower Units  
CFM  
CFM  
CFM  
CFM  
Minimum Round Square  
Model  
Volts  
Amps*  
RPM  
Equivalent CFM#  
Duct Size  
Inches  
28  
B100 Single  
B200 Dual  
115  
115  
1.7  
3.4  
1550  
1550  
300  
600  
450  
900  
286  
572  
270  
540  
240  
480  
6” (or equivalent)  
8” (or equivalent)  
50  
* Note: Add 0.5 amp for each halogen light. Hood is available halogen lights (2 lights: 30” - 41”, 3 lights: 42” - 48”).  
#Because the Magic Lung® uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently  
than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.  
U
C
US  
R
L
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 04/08  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Tiger Radar Detector V1 User Manual
Tricity Bendix Washer BIW 126 W User Manual
Uniden Cordless Telephone DECT2185 User Manual
Unitron Hearing Aid Hearing Aid BTE User Manual
Velodyne Acoustics Speaker VX 10 User Manual
Vidikron Projection Television Vision 120 User Manual
Viper Vacuum Cleaner VR ACF User Manual
VTech Cordless Telephone VT1712 User Manual
VXI Network Hardware 82 0102 000 User Manual
Wagner SprayTech Paint Sprayer 0261 951 User Manual