and operate the compressor from an external 12 volt DC source.
4. To avoid over-inflation, carefully follow instructions on articles to be inflated.
5. Never leave compressor unattended while in use. Allow unit to cool for
five minutes after 10 minutes of continuous operation.
6. Do not use accessories that are not designed to be used with the
compressor.
7. Do not place battery pack on heater and keep it out of sunlight.
8. Do not charge battery when it is at or above 122° F (50° C). Allow the
battery pack to cool before charging.
CONTENTS
1. INTRODUCTION .................................................... 4
2. ADDITIONAL KEY FEATURES................................... 5
3. ATTACHING THE AIR HOSE.................................... 5
4. POWERING THE COMPRESSOR ............................. 6
4.1 Powering from the battery pack.........................
4.2 DC Power Adapter Use................................... 6
5. CHARGING/RECHARGING THE BATTERY PACK...... 7
5.1 AC Recharge of battery pack.......................... 7
6. COMPRESSOR/TIRE INFLATOR ............................... 8
6.1 Tire inflation or products with a valve stem....... 8
6.2 Inflate other articles (without valve stem)....... 8, 9
7. TYPICAL INFLATION TIRES ...................................... 9
8. MAINTENANCE/REPLACEMENT PARTS .................. 9
9. BATTERY REMOVAL/REPLACEMENT...................... 10
10. BATTERY DISPOSAL .............................................. 10
11. SPECIFICATIONS.................................................. 10
WARRANTY......................................................... 11
Download from Www.Somanuals.com. All Manuals Search And Download.
3
1.
INTRODUCTION
Congratulations on selecting the Vector AirPro™ Model VEC256
Compressor. This system is an advanced high-pressure (up to 260 PSI)
multi-use air compressor system with unique features that set it far above
the value and utility of ordinary compressors for mobile use. It is supplied
with a standard tire valve chuck for filling auto, truck, bike, and motorcycle
tires. Additionally, two different adapters are supplied to inflate soccer balls,
footballs, and popular inflatables. These adapters are conveniently stored
in a hatch in the compressor body. It is powered from its own snap-on/off
powerful battery to be used anywhere it is needed. It can also operate
from a standard 12 volt DC electrical system found on: trucks, cars, boats,
airplanes, RVs and tractors, using the supplied DC Power Adapter. A
supplied standard 110 VAC charger recharges the battery when required.
Typically, up to three completely flat tires can be inflated before the snap-on
battery has to be recharged.
A customer can purchase extra snap-on battery packs if completely cordless
operation is required (Part VEC194). The compressor with the snap-on DC
Power Adapter is ideal for use with Vector 12 volt DC cordless, portable,
rechargeable DC Power supplies if extended operating time in the field is
required.
HOSE RETAINING
RING
NOZZLE HATCH
COMPRESSOR
OUTLET
COVER
FIGURE 1
RIBBED BRASS
FITTING
TRIGGER LOCK
COMPRESSOR
HOSE
TRIGGER
SWITCH
TIRE CHUCK
The Compressor On/Off Switch controls operation of the compressor. It con-
veniently is depressed and released to control inflation. An exact pressure is
obtained by observing the gauge and releasing the trigger when the correct
pressure is achieved. For longer inflation operations, the Trigger Lock can
be moved laterally to lock the trigger in the ON position. Pushing the trigger
lock to the opposite direction releases the trigger (OFF) and
5 inflation stops.
Download from Www.Somanuals.com. All Manuals Search And Download.
2.
ADDITIONAL KEY FEATURES
• Trigger Switch with lock to allow hands free operation
• Corded -includes a DC power adapter for use with standard 12 volt
power supply
• Battery Pack includes non-spillable, maintenance-free, heavy duty, sealed,
high-density lead-acid battery
• Requires no maintenance (other than recharging and cleaning) for
optimum operation
• Supplied 110 volt AC charger is Underwriter Laboratories (UL) safety
tested and listed
• Battery Charging LED on battery automatically activated during
AC recharge
• Analog Pressure Gauge to 260 PSI
• Nozzle Hatch for storing nozzles
NOZZEL HATCH
COVER
NOZZLES
FIGURE 2
PRESSURE
GAUGE
CAUTION: This unit is delivered in a partially charged state - you must
fully charge it before using it for the first time. Initial AC Charge should
be for 10 hours. Refer to section 5 for use of AC Adapter and
detailed charging instructions.
3.
ATTACHING THE AIR HOSE
The Air Hose is supplied as a separate item from the compressor body. The
hose has a ribbed brass fitting at one end and a standard tire chuck at the
other end. To use the hose it must first be connected to the compressor outlet.
Loosen the hose retaining ring (counterclockwise), insert the hose fitting
into the short, rubber sealing sleeve. Make sure the hose fitting is inserted
fully into the sleeve. Partially tighten (clockwise) the hose-retaining ring and
push the fitting in further. Do this two or three times until the fitting is firmly
attached and the ring is firmly tightened.
WARNING: Improperly attached hoses or nozzles can fly out under
compressor pressure. Make sure the connections are tight.
Download from Www.Somanuals.com. All Manuals Search And Download.
5
WARNINGS:
1. There is risk of dust or dirt projectiles being released if the compressor
hose or nozzles are not clean when the compressor is turned on.
2. Wearing protective goggles while operating this compressor can protect
eyes from flying particles of dust and dirt. Failure to follow instructions
ay cause property damage, and/or personal injury.
3. Keep out of reach of children.
4.
POWERING THE COMPRESSOR
The compressor can be powered either from a supplied battery pack or from
a supplied DC Power Adapter.
4.1 POWERING FROM THE BATTERY PACK
The supplied battery pack powers the compressor for short duration, cordless
operation. The Battery Pack should be fully charged initially before use (see
section 5 for charging instructions.)
To connect the charged battery pack to the compressor, align the battery
pack so that the battery release buttons snap onto the compressor. The
battery pack fits only one way to ensure correct polarity of the contacts.
To remove the Battery Pack, press the Battery Pack release buttons and the
battery pack will release from the compressor.
4.2 DC POWER ADAPTER USE
The DC power adapter can power the compressor for longer operation from
an external 12 volt power source.
The DC Power Adapter has a fused DC plug and connecting cord stored
inside the DC Power Adapter. To use the DC Power Adapter, first remove the
DC plug from it’s storage in the adapter. Deploy the cord from storage, and
connect the DC Power Adapter to the compressor. Make sure it snaps into
position. Connect the DC plug to a 12 Volt DC source. To remove the DC
Power Adapter, press it’s release buttons and the Adapter will release from the
compressor. Put the DC Plug and cord in the Adapter for storage after use.
FIGURE 3
CONTACT
FUSED DC
PLUG
RELEASE BUTTON
7
Download from Www.Somanuals.com. All Manuals Search And Download.
5.
CHARGING/RECHARGING THE BATTERY PACK
Lead-acid batteries require maintenance to maintain a full charge and
to ensure good battery life. All lead-acid batteries suffer from self-dis-
charge over time and more rapidly when they are at higher temperatures.
Therefore, these types of batteries need periodic charging to replace energy
lost through self-discharge. When the Battery Pack is not in use Vector
recommends that the battery is recharged at least every 60 days.
All batteries must be recharged as soon as possible after each use. If a battery
is allowed to remain in a discharged state, battery life will be reduced.
NOTE: Recharging battery after each use will prolong battery life;
frequent heavy discharges between recharges will reduce battery life.
Overcharging will reduce battery life. Never charge for more than 24 hours.
The time required to fully recharge the battery pack depends on the charge
status of the battery after its use. If the battery is discharged from recent use
recharge the battery for 8 hours.
5.1 AC RECHARGE OF BATTERY PACK
AC Recharge requires the use of the supplied AC/DC Adapter. The AC
adapter must be powered from 110 volt AC, 60 Hz North American
standard AC receptacles. The battery pack must be removed from the
compressor body to gain access to the recharge port.
CONTACTS
FIGURE 4
RECHARGE PORT
RECHARGE LED
RELEASE BUTTON
110 VOLT AC WALL
ADAPTOR
To remove the battery pack from the compressor body for charging: Make
sure the trigger switch is OFF. Press both battery pack release buttons at the
same time. Pull the battery pack down away from the compressor body. Insert
the barrel connector of the AC Adapter into the battery pack
receptacle (Recharge Port). Plug the AC Adapter into a 110 VAC stan-
dard household receptacle. Observe the red LED lights. Charge for the
recommended time. Do not overcharge! Disconnect and store the AC
Recharge Adapter from the battery pack and AC source when not in use.
Download from Www.Somanuals.com. All Manuals Search And Download.
7
6.
COMPRESSOR/TIRE INFLATOR
This 12 Volt DC compressor is the ultimate compressor for all Vehicles, Trailer Tires
and recreational inflatables. Three different sized nozzles are supplied.
IMPORTANT: Read Safety Instructions Carefully To Avoid Possible Injury
Or Property Damage.
WARNINGS: The compressor is capable of inflating to 260 pounds per
square inch (PSI) pressure (approximately 18 kg/cm). To avoid over-
inflation, carefully follow instructions on articles to be inflated. Never
exceed recommended pressures. Bursting articles can cause serious
injury. Always check pressure with the pressure gauge. Never leave
compressor unattended while in use. Allow unit to cool for five minutes
after10 minutes of continuous operation.
6.1 TIRE INFLATION OR PRODUCTS WITH A VALVE STEM
1. Place connector (chuck) on valve stem.
2. Push connector toward valve stem and close thumb latch.
3. Make sure connector is pushed on to valve stem as far as possible
before closing thumb latch.
4. Turn on the compressor (for larger items the trigger can be latched).
5. Observe pressure with the pressure gauge.
6. When desired pressure is reached, open thumb latch and remove
connector from valve stem.
7. Turn OFF compressor power switch.
IMPORTANT: Always leave the tire chuck thumb latch in the open
position when storing unit.
6.2 INFLATE OTHER ARTICLES (WITHOUT VALVE STEM)
Inflation of other than tires requires use of one of the nozzles (adapters). A
nozzle can be attached to the tire chuck or it can directly be connected to
the compressors outlet if the hose is removed.
A nozzle can be attached to the tire chuck. Open the nozzle hatch cover
and remove the required nozzle. Close the nozzle hatch cover. Place the tire
chuck over the nozzle fitting and secure by moving the chuck thumb latch so
it is parallel with the hose. Make sure the nozzle is clean and secure before
turning on the compressor. After use, release the nozzle from the chuck by
lifting the latch. Return the nozzle to the nozzle hatch.
A nozzle can also be directly attached to the compressor outlet if the hose
9 is not required.
Download from Www.Somanuals.com. All Manuals Search And Download.
1. Open the nozzle hatch cover and remove the required nozzle.
2. Remove the hose from the compressor outlet by loosening (counterclock-
wise) the hose retaining ring and sliding out the ribbed brass fitting.
3. Close the nozzle hatch cover.
4. Insert the selected nozzle into the compressor outlet and secure it by
tightening the hose-retaining ring as above.
5. After using the compressor, remove and store the nozzle in the
nozzle hatch.
Refer to “Typical Inflation Times” for approximate pressure and time. Smal-
litems like volleyballs, footballs, etc. inflate very rapidly.
• Insert nozzle (e.g needle) into item to be inflated and inflate to
desired pressure
• Turn ON compressor switch - inflate to desired pressure or fullness
7.
TYPICAL INFLATION TIMES
The following are approximate pressure and inflation times for various
items.
WARNING: Always follow tire manufacturers recommendations for
pressure on item to be inflated.
VEHICLE AND TRAILER TIRES
TIRE SIZE
............. PRESSURE
........... TIME FROM “0” PRESSURE
155/80R 13”
185/70R 14”
235/75R 15”
235/85R 16”
.... 26 PSI ..........................2.50 MIN.
.... 30 PSI ..........................4.50 MIN.
.... 30 PSI ..........................6.50 MIN.
.... 50 PSI ..........................16.00 MIN.
BICYCLE TIRES
TIRE SIZE
............. PRESSURE
............ TIME FROM “0” PRESSURE
27
X
1” RACING ....... 10 PSI ..........................40 SEC.
INFLATABLE ARTICLES
ITEM
............................................ PRESSURE
TIME FROM
“0” PRESSURE
FOOTBALL
BASKETBALL
VOLLEYBALL
.......... 13 PSI ..........................24 SECONDS
.......... 9 PSI ...........................20 SECONDS
.......... 5 PSI ...........................6 SECONDS
8.
MAINTENANCE/REPLACEMENT PARTS
For replacement parts (batteries, DC power adapters, AC charging
adapters, cables, etc.), contact Vector Technical Support: (954) 584-4446 or toll
free at 866-584-5504. Periodically, cables, hose, nozzles and connectors should
be inspected for damage, corrosion, dust and dirt. If surfaces are dirty, they
Download from Www.Somanuals.com. All Manuals Search And Download.
9
can be wiped clean with a cloth moistened with water and a drop of detergent.
Battery Pack contacts can be wiped clean with a dry cloth.
9.
BATTERY REMOVAL/REPLACEMENT
The battery in the battery pack should be replaced with a new one when the
operating capacity is reduced to about one half or the ability to inflate one
and one half average sized automobile tires. Make sure that the battery is
fully charged before determining that the battery pack should be replaced.
Contact Vector Technical Support and ask for part VEC194. This battery
pack is also used with other Vector products that include portable infla-
tors and spotlights. For more details, please contact our Sales or Technical
Support Department at 1-866-584-5504.
10.
BATTERY DISPOSAL
Contains a maintenance-free, sealed, non-spillable, lead acid battery, which
must be disposed of properly. Most states require recycling-contact your local
municipal authority for information.
Non-spillable sealed lead-acid battery, must be recycled or disposed of
properly. Recycling is required -contact your local authority for information.
DISPOSAL QUESTIONS FOR USA CALL toll-free 877-288-7722.
WARNINGS:
•
Do not dispose of the battery pack in fire as this may result in an explo-
sion
•
Before disposing of the battery pack, protect exposed terminals with
heavy-
duty electrical tape to prevent shorting (shorting can
fire). Failure to comply with local, state and
result in injury or
federal regulations can result
in fines, or imprisonment
11.
SPECIFICATIONS
Battery .......... 12 Volt 3 Amp Hour, Non-spillable Sealed Lead-Acid
Compressor ......................................................260 PSI Maximum
11Download from Www.Somanuals.com. All Manuals Search And Download.
VECTOR 1 YEAR LIMITED WARRANTY PROGRAM
This limited warranty program is the only one that applies to this product, and
it sets forth all the responsibilities of Vector Manufacturing, Ltd., regarding
this product. There is no other warranty other than those described herein.
This Vector Manufacturing, Ltd. product is warranted, to the original
purchaser only, to be free of defects in materials and workmanship for two
years from the date of purchase without additional charge. The warranty
does not extend to subsequent purchasers or users. Vector Manufacturing,
Ltd. will not be responsible for any amount of damage in excess of the
retail purchase price of the product under any circumstances. Incidental
and consequential damages are specifically excluded from coverage under
this warranty.
This product is not intended for commercial use. This warranty does not apply
to accessories or damage to units from misuse or incorrect installation. Misuse
includes wiring or connecting to improper polarity power sources.
RETURN/REPAIR POLICY: Defective products, other than accessories,
may be returned postage prepaid to Vector Manufacturing. Any defective
product, other than accessories, that is returned to Vector Manufacturing
within 10 days of the date of purchase will be replaced free of charge.
If such a product is returned more than 30 days but less than two years
from the purchase date, Vector Manufacturing will repair the unit or, at its
option, replace it free of charge.
If the unit is repaired, new or reconditioned replacement parts may be
used, at Vector Manufacturing’s option. A unit may be replaced with a new
or reconditioned unit of the same or comparable design. The repaired or
replaced unit will then be warranted under the terms of the remainder of the
warranty period. The customer is responsible for the shipping charges on
all returned items. During the warranty period, Vector Manufacturing, Ltd.
will be responsible for the return shipping charges.
LIMITATIONS: This warranty does not cover accessories, bulbs, fuses and
batteries, defects resulting from normal wear and tear (including chips,
scratches, abrasions, discoloration or fading due to usage or exposure to
sunlight), accidents, damage during shipping to our service facility, altera-
tions, unauthorized use or repair, neglect, misuse, abuse, failure to follow
instructions for care and maintenance, fire, flood, and acts of God.
If your problem is not covered by this warranty, call our Technical Support
Download from Www.Somanuals.com. All Manuals Search And Download.
11
Department at (954) 584-4446 Ext.1 19 for general repair information and
charges if applicable.
STATE LAW RIGHTS: This warranty gives you specific legal rights. Some
states do not allow limitations on how long an implied warranty lasts or
the exclusion or limitation of incidental or consequential damages, so the
exclusions or imitations stated herein may not apply. This warranty gives
the purchaser specific legal rights. Other rights, which vary from state to
state, may apply.
TO REQUEST WARRANTY SERVICE FOR THIS PRODUCT: Contact Vector
Manufacturing Technical Support by telephone, fax or mail. We suggest
that you keep the original packaging in case you need to ship the unit.
When returning a product, include your name, address, phone number,
dated sales receipt (or copy), and a description of the reason for return
and product serial number. After replacing the unit, we will return it to you
within four weeks.
WARRANTY ACTIVATION: Please complete Warranty Activation Card and
mail to Vector Manufacturing. Enter “VEC256” as Model and Compres-
sor as “Product Type”. All Vector Manufacturing, Ltd. products must be
registered within (10) days of purchase. To activate this warranty, mail
completed registration form, a copy of the original sales receipt and
required fee (if activating extended warranty) to:
WARRANTY REGISTRATION
VECTOR MANUFACTURING, Ltd.
4140 S.W. 28th Way; Fort Lauderdale, Florida 33312
© 2003 VECTOR MANUFACTURING, Ltd.
FT. LAUDERDALE, FL 33312 MADE IN CHINA
12Download from Www.Somanuals.com. All Manuals Search And Download.
|