UNVENTED (VENT-FREE)
PROPANE/LP GAS LOG HEATER
VARIABLE MANUALLY-CONTROLLED MODELS ALSO
DESIGN-CERTIFIED AS VENTED DECORATIVE APPLIANCES
OWNER’S OPERATION AND INSTALLATION MANUAL
FLAME-MAX®
Models VYS18PWA,
VYS24PWA, and
VYS30PWA (Millivolt)
AUTO
OFF
ON
Remote Ready
Patent Pending
WARNING:Improperinstallation,adjust-
ment,alteration,service,ormaintenance
can cause injury or property damage.
Refer to this manual for correct installa-
tion and operational procedures. For as-
sistance or additional information con-
sult a qualified installer, service agency,
or the gas supplier.
WARNING: If the information in this manual
is not followed exactly, a fire or explosion
may result causing property damage, per-
sonal injury, or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Immediatelycallyourgassupplierfrom
a neighbor’s phone. Follow the gas
supplier’s instructions.
WARNING:Thisapplianceisforinstalla-
tiononlyinasolid-fuelburningmasonry
or UL127 factory-built fireplace, or in an
approved ventless firebox. It is design
certified for these installations in accor-
dancewithANSIZ21.11.2.Exception:Do
not install this appliance in a factory-
built fireplace that includes instructions
stating it has not been tested or should
not be used with unvented gas logs.
• If you cannot reach your gas supplier,
call the fire department.
— Installation and service must be per-
formed by a qualified installer, service
agency, or the gas supplier.
WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in
which it is installed. Provisions for adequate combustion and ventilation air must be
provided. Refer to Air for Combustion and Ventilation section on page 4 of this manual.
This appliance may be installed in an aftermarket*, permanently located, manufactured
(mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
Save this manual for future reference.
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
SAFETY
LOCAL CODES
Install and use heater with care. Follow all
localcodes.Intheabsenceoflocalcodes,use
the latest edition of The National Fuel Gas
Code ANSI Z223.1/NFPA 54*.
PRODUCT
FEATURES
INFORMATION
Continued
OPERATION
13. Do not use this heater to cook food or
burn paper or other objects.
This heater is clean burning. It requires no
outside venting. There is no heat loss out a
vent or up a chimney. Heat is generated by
realistic,dancingyellowflames.Thisheater
is designed for vent-free operation with flue
damper closed. It has been tested and ap-
proved to ANSI Z21.11.2 standard for
unvented heaters. State and local codes in
some areas prohibit the use of vent-free
heaters. This heater may also be operated as
a vented decorative (ANSI Z21.60) product
byopeningthefluedamper(non-thermostat
operation only).
*Available from:
14. Do not use heater if any part has been
exposed to or under water. Immediately
call a qualified service technician to in-
spect the room heater and to replace any
part of the control system and any gas
control which has been under water.
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
15. Do not operate heater if any log is bro-
ken. Do not operate heater if a log is
chipped (dime-sized or larger).
Quincy, MA 02269
Note: Where listed vented decorative logs
are required, thermostat operation is not
permitted.
16. Turn heater off and let cool before ser-
vicing, installing, or repairing. Make sure
the selector switch is in the OFF posi-
tion. Only a qualified service person
should install, service, or repair heater.
UNPACKING
SAFETY PILOT
ThisheaterhasapilotwithanOxygenDeple-
tion Sensing (ODS) safety shutoff system.
The ODS/pilot is a required feature for vent-
free room heaters. The ODS/pilot shuts off
the heater if there is not enough fresh air.
CAUTION: Do not remove the
metal data plates from the grate
assembly. Thedataplatescontain
important product information.
17. Make sure the selector switch is in the
OFF position when you are away from
home for long periods of time.
18. Operating heater above elevations of
4,500 feet could cause pilot outage.
1. Remove logs and heater base assem-
bly from carton. Note: Do not pick up
heater base assembly by the burner.
This could damage heater. Always
handle base assembly by grate.
PIEZO IGNITION SYSTEM
19. Provide adequate clearances around air
openings.
This heater has a piezo ignitor. This system
requires no matches, batteries, or other
sources to light heater.
PRODUCT
IDENTIFICATION
Flame-Max®
Vintage Oak Logs
2. Remove all protective packaging ap-
plied to logs and heater for shipment.
REMOTE CONTROL
ACCESSORIES
There are four optional remote controls that
can be purchased separately for this log
heater:
3. Check all items for any shipping dam-
age. If damaged, promptly inform
dealer where you bought heater.
• wall switch
• wall thermostat
• hand-held ON/OFF remote
• hand-held thermostat remote
Optional
Remote
Control
One Piece
Log Set
See Accessories, page 24.
The wall thermostat or hand-held thermo-
stat may not be used where vented decora-
tive listing is required.
W
A
R
M
E
R
C
O
O
T
E
L
M
P
E
R
A
A
U
U
T
T
O
O
O
N
O
O
F
O
F
F
F
N
Piezo
I
H
Ignitor
L
Base Assembly
O
O
F
F
N
O
T
I P
O
L
Optional
Selector
Switch
Flame Adjustment Knob
Control Knob
Figure 1 - Product Identification
105190
3
Download from Www.Somanuals.com. All Manuals Search And Download.
VANGUARD
UNVENTED PROPANE/LP GAS LOG HEATER
Confined and Unconfined Space
PROVIDING ADEQUATE
VENTILATION
AIR FOR
The National Fuel Gas Code, ANSI Z223.1/
NFPA 54 defines a confined space as a
space whose volume is less than 50 cubic
feet per 1,000 Btu per hour (4.8 m3 per kw)
of the aggregate input rating of all appli-
ances installed in that space and an uncon-
fined space as a space whose volume is not
less than 50 cubic feet per 1,000 Btu per
hour (4.8 m3 per kw) of the aggregate input
rating of all appliances installed in that
space. Rooms communicating directly with
the space in which the appliances are in-
stalled*, through openings not furnished
with doors, are considered a part of the
unconfined space.
COMBUSTION AND
VENTILATION
The following are excerpts from National
Fuel Gas Code ANSI Z223.1/NFPA 54, Sec-
tion5.3, AirforCombustionandVentilation.
WARNING: This heater shall
notbeinstalledinaconfinedspace
or unusually tight construction
unless provisions are provided
foradequatecombustionandven-
tilation air. Read the following in-
structions to insure proper fresh
air for this and other fuel-burning
appliances in your home.
All spaces in homes fall into one of the three
following ventilation classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space
The information on pages 4 through 6 will
help you classify your space and provide
adequate ventilation.
Today’s homes are built more energy effi-
cient than ever. New materials, increased
insulation, and new construction methods
helpreduceheatlossinhomes.Homeowners
weather strip and caulk around windows and
doorstokeepthecoldairoutandthewarmair
in. During heating months, home owners
want their homes as airtight as possible.
Unusually Tight Construction
* Adjoining rooms are communicating only
iftherearedoorlesspassagewaysorventila-
tion grills between them.
The air that leaks around doors and win-
dows may provide enough fresh air for
combustion and ventilation. However, in
buildings of unusually tight construction,
you must provide additional fresh air.
Unusually tight construction is de-
fined as construction where:
While it is good to make your home energy
efficient, your home needs to breathe. Fresh
air must enter your home. All fuel-burning
appliances need fresh air for proper com-
bustion and ventilation.
a. walls and ceilings exposed to the
outside atmosphere have a con-
tinuous water vapor retarder with
a rating of one perm (6x10-11 kg
per pa-sec-m2) or less with open-
ings gasketed or sealed and
Exhaustfans, fireplaces, clothesdryers, and
fuel burning appliances draw air from the
house to operate. You must provide ad-
equate fresh air for these appliances. This
will insure proper venting of vented fuel-
burning appliances.
b. weather stripping has been
added on openable windows and
doors and
c. caulking or sealants are applied
to areas such as joints around
window and door frames, be-
tween sole plates and floors, be-
tween wall-ceiling joints, be-
tween wall panels, at penetra-
tions for plumbing, electrical, and
gas lines, and at other openings.
If your home meets all of the three
criteria above, you must provide ad-
ditional fresh air. See Ventilation Air
From Outdoors, page 6.
If your home does not meet all of the
three criteria above, proceed to De-
termining Fresh-Air Flow For Heater
Location, page 5.
105190
4
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
AIR FOR
COMBUSTION AND
VENTILATION
Continued
DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION
Determining if You Have a Confined or Unconfined Space
Use this work sheet to determine if you have a confined or unconfined space.
Space: Includestheroominwhichyouwillinstallheaterplusanyadjoiningroomswithdoorlesspassagewaysorventilationgrillsbetween
the rooms.
1. Determine the volume of the space (length x width x height).
Length x Width x Height = _____________ cu. ft. (volume of space)
Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)
If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of
the space.
2. Multiply the space volume by 20 to determine the maximum Btu/Hr the space can support.
_______________ (volume of space) x 20 = (maximum Btu/Hr the space can support)
Example: 2560 cu. ft. (volume of space) x 20 = 51,200 (maximum Btu/Hr the space can support)
3. Add the Btu/Hr of all fuel burning appliances in the space.
Vent-free heater
Gas water heater*
Gas furnace
Vented gas heater
Gas fireplace logs
_____________ Btu/Hr
_____________ Btu/Hr
_____________ Btu/Hr
_____________ Btu/Hr
_____________ Btu/Hr
Example:
Gas water heater
Vent-free heater + 31,500 Btu/Hr
Total 71,500 Btu/Hr
40,000 Btu/Hr
=
Other gas appliances* + _____________ Btu/Hr
Total _____________ Btu/Hr
=
* Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
_________________ Btu/Hr (maximum the space can support)
_________________ Btu/Hr (actual amount of Btu/Hr used)
Example: 51,200 Btu/Hr (maximum the space can support)
71,500 Btu/Hr (actual amount of Btu/Hr used)
The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space cansupport.
You must provide additional fresh air. Your options are as follows:
A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin-
ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 6.
B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6.
C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no
additional fresh air ventilation.
WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space
or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of
themethodsdescribedintheNationalFuelGasCode,ANSIZ223.1/NFPA54,Section5.3orapplicablelocalcodes.
Continued
105190
5
Download from Www.Somanuals.com. All Manuals Search And Download.
VANGUARD
UNVENTED PROPANE/LP GAS LOG HEATER
AIR FOR
12"
COMBUSTION AND
VENTILATION
Ventilation
Continued
Ventilation Grills
Into Adjoining Room,
Option 2
Grills
Into Adjoining
Room,
VENTILATION AIR
Or
Remove
Door into
Adjoining
Room,
Option
3
Ventilation Air From Inside
Building
Option 1
Thisfreshairwouldcomefromanadjoining
unconfined space. When ventilating to an
adjoining unconfined space, you must pro-
vide two permanent openings: one within
12" of the ceiling and one within 12" of the
floor on the wall connecting the two spaces
(see options 1 and 2, Figure 2). You can also
remove door into adjoining room (see op-
tion 3, Figure 2). Follow the National Fuel
Gas Code ANSI Z223.1/NFPA 54, Section
5.3, Air for Combustion and Ventilation for
required size of ventilation grills or ducts.
12"
Figure 2 - Ventilation Air from Inside Building
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation
grills or ducts. You must provide two per-
manent openings: one within 12" of the
ceiling and one within 12" of the floor.
Connect these items directly to the outdoors
orspacesopentotheoutdoors.Thesespaces
include attics and crawl spaces. Follow the
NationalFuelGasCodeANSIZ223.1/NFPA
54, Section 5.3, Air for Combustion and
Ventilation for required size of ventilation
grills or ducts.
Ventilated
Attic
Outlet
Air
Outlet
Air
To Attic
To
Crawl
Space
IMPORTANT: Do not provide openings for
inlet or outlet air into attic if attic has a
thermostat-controlledpowervent.Heatedair
enteringtheatticwillactivatethepowervent.
Inlet
Air
Ventilated
Crawl Space
Inlet Air
Figure 3 - Ventilation Air from Outdoors
105190
6
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
INSTALLATION
MINIMUM FIREPLACE
WARNING: Never install the
heater
CLEARANCE TO
NOTICE: This heater is intended
foruseassupplementalheat.Use
this heater along with your pri-
mary heating system. Do not in-
stall this heater as your primary
heat source. If you have a central
heating system, you may run
system’scirculatingblowerwhile
using heater. This will help circu-
late the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.
• in a bedroom or bathroom un-
less installed as a vented ap-
pliance, see page 10
• in a recreational vehicle
• where curtains, furniture,
clothing, or other flammable
objectsarelessthan42inches
from the front, top, or sides of
the heater
COMBUSTIBLE MATERIALS
Log Size Side Wall Ceiling
18", 24",
and 30"
16"
42"
LOG SIZING REQUIREMENTS
Log
Minimum Firebox
Size Height Depth Front Rear *
Width Width
• in high traffic areas
• in windy or drafty areas
18"
24"
30"
17"
17"
17"
14"
14"
14"
24"
28"
34"
20"
21"
24"
CAUTION: This heater cre-
ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities (such as, but
not limited to, tobacco smoke,
aromatic candles, cleaning flu-
ids,oilorkerosenelamps,etc.)in
the air exist, may discolor walls
or cause odors.
* Measured at 14" depth.
WARNING: A qualified ser-
vice person must install heater.
Follow all local codes.
Carefullyfollowtheinstructionsbelow.This
will ensure safe installation into a masonry,
UL127-listed manufactured fireplace, or
listed vent-free firebox.
NOTICE:Stateorlocalcodesmay
onlyallowoperationofthisappli-
ance in a vented configuration.
Check your state or local codes.
Minimum Clearances For Side
Combustible Material, Side Wall,
and Ceiling
A. Clearances from the side of the fireplace
cabinet to any combustible material and
wall should follow diagram in Figure 4.
WARNING: Before installing
in a solid fuel burning fireplace,
thechimneyflueandfireboxmust
be cleaned of soot, creosote,
ashes and loose paint by a quali-
fied chimney cleaner. Creosote
willigniteifhighlyheated. Adirty
chimney flue may create and dis-
tribute soot within the house. In-
spectchimneyfluefordamage. If
damaged,operateheaterwithflue
damper closed.
IMPORTANT:Vent-freeheatersaddmois-
ture to the air. Although this is beneficial,
installing heater in rooms without enough
ventilation air may cause mildew to form
from too much moisture. See Air for Com-
bustion and Ventilation, pages 4 through 6.
Example:Thefaceofamantel, bookshelf,
etc. is made of combustible material and
protrudes 3 1/2" from the wall. This com-
bustible material must be 4" from the side
of the fireplace cabinet (see Figure 4).
CHECK GAS TYPE
Note:When installing your gas logs into
a manufactured firebox, follow firebox
manufacturer’s instructions for minimum
clearances to combustible materials.
Useonlypropane/LPgas.Ifyourgassupply
is not propane/LP, do not install heater. Call
dealer where you bought heater for proper
type heater.
B. Clearances from the top of the fireplace
opening to the ceiling should not be less
than 42 inches.
INSTALLATION AND
CLEARANCES (Vent-Free
Operation Only)
WARNING: Seal any fresh air
vents or ash clean-out doors lo-
catedonfloororwalloffireplace.
If not, drafting may cause pilot
outage or sooting. Use a heat-
resistant sealant. Do not seal
chimney flue damper.
Example
WARNING:Maintainthemini-
mum clearances. If you can, pro-
vide greater clearances from
floor, ceiling, and adjoining wall.
*
*Minimum 16 inches from Side Wall
Figure 4 - Minimum Clearance for Com-
bustible to Wall
Continued
105190
7
Download from Www.Somanuals.com. All Manuals Search And Download.
VANGUARD
UNVENTED PROPANE/LP GAS LOG HEATER
If Using Mantel
IMPORTANT: If you cannot meet these
minimum clearances, you must operate
heater with chimney flue damper open. Go
to Installing Damper Clamp Accessory for
Vented Operation, page 10.
INSTALLATION
You must have noncombustible material(s)
above the fireplace opening. Noncombus-
tible materials (such as slate, marble, tile,
etc.) must be at least 1/2 inch thick. With
sheet metal, you must have noncombustible
material behind it. Noncombustible mate-
rial must extend at least 8 inches up (for all
models). If noncombustible material is less
than 12", you must install the fireplace hood
accessory (24" and 30” models only). Even
if noncombustible material is more than
12", you may need the hood accessory to
deflect heat away from your mantel shelf.
SeeFigure5andFigures6and7, page9, for
minimum clearances.
Continued
NOTICE: Manual control heaters
maybeusedasaventedproduct.
If so, you must always run heater
with chimney flue damper open.
If running heater with damper
open, noncombustible material
above fireplace opening is not
needed. Go to Installing Damper
Clamp Accessory for Vented
Operation, page 10
Minimum Noncombustible
Material Clearances
Noncombustible
Material Distance (A)
Requirements for
Safe Installation
If Not Using Mantel
Note: If using a mantel, proceed to If Using
Mantel. If not using a mantel, follow the
information below.
12" or more
Noncombustible material OK.
Between 8" and 12"
24" or 30" Models: Install fireplace hood accessory
(GA6050, GA6052, or GA6053 see Accessories,
page 24).
You must have noncombustible material(s)
above the fireplace opening. Noncombus-
tible materials (such as slate, marble, tile,
etc.) must be at least 1/2 inch thick. With
sheet metal, you must have noncombustible
material behind it. Noncombustible mate-
rial must extend at least 8" up (for all mod-
els). If noncombustible material is less than
12", you must install the fireplace hood
accessory (24" and 30" models only). See
Figure 5 at right for minimum clearances.
18" Model: Noncombustible material OK.
Less than 8"
Noncombustible material must be extended to at
least 8". See Between 8" and 12", above. If you
cannot extend material, you must operate heater
with flue damper open.
Heat Resistant
Material
IMPORTANT: If you cannot meet these
minimum clearances, you must operate
heater with chimney flue damper open. Go
to Installing Damper Clamp Accessory for
Vented Operation, page 10.
(A)
Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace
105190
8
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
Mantel Shelf
Underside of
Mantel Shelf
INSTALLATION
10"
8"
Continued
6"
MANTEL CLEARANCES
2 1/2"
Inadditiontomeetingnoncombustiblemate-
rial clearances, you must also meet required
clearances between fireplace opening and
mantel shelf. If you do not meet the clear-
ances listed below, you will need a hood.
All minimum
distances are
in inches
Minimum Non-
Combustible
Material
(A)
Log Set
Determining Minimum Mantel
Clearance
12"
8"
18"
8"
20"
14"
22"
17"
24"
20"
24” and 30” Models
18" Model
If you meet minimum clearance between
mantel shelf and top of fireplace opening, a
hood is not required (see Figure 6).
Top of Fireplace
Opening
Minimum Non-
Combustible
Material Height
Distances to
Underside of
Mantel
Determining Minimum Mantel
Clearance When using a Hood
If minimum clearances in Figure 6 are not
met, you must have a hood. When using a
hood there are still certain minimum mantel
clearancesrequired.Followminimumclear-
ances shown in Figure 7 when using hood.
Figure 6 - Minimum Mantel Clearances Without Using Hood
Mantel Shelf
12"
Underside of
Mantel Shelf
NOTICE:Surfacetemperaturesof
adjacent walls and mantels be-
comehotduringoperation.Walls
and mantels above the firebox
may become hot to the touch. If
installedproperly,thesetempera-
turesmeettherequirementofthe
national product standard. Fol-
low all minimum clearances
shown in this manual.
10"
8"
6"
2 1/2"
All minimum
distances are
in inches
Minimum Non-
Combustible
Material
8"
Min.
12"
15"
18"
20"
Top of Fireplace
Opening
NOTICE: If your installation does
notmeettheminimumclearances
shown, you must do one of the
following:
Hood
Distances to
Underside of
Mantel
(GA6050, GA6052,
or GA6053)
• operate the logs only with the
flue damper open
• raise the mantel to an accept-
able height
• remove the mantel
Figure 7 - Minimum Mantel Clearances When Using Hood
FLOOR CLEARANCES
A. If installing appliance on the floor level,
you must maintain the minimum dis-
tance of 14" to combustibles (see Fig-
ure 8).
Combustible
Hearth
Material
Combustible
Material
14"
Min.
5”
B. If combustible materials are less than
14" to the fireplace, you must install
appliance at least 5" above the combus-
tible flooring (see Figure 9).
Min.
Noncombustible Material
Figure 8 - Minimum Fireplace Clearances
If Installed at Floor Level
Figure 9 - Minimum Fireplace Clearances
Above Combustible Flooring
Continued
105190
9
Download from Www.Somanuals.com. All Manuals Search And Download.
VANGUARD
UNVENTED PROPANE/LP GAS LOG HEATER
Damper Clamp
INSTALLATION
Continued
INSTALLING DAMPER
CLAMP ACCESSORY FOR
VENTED OPERATION
Damper
Damper
Clamp
Damper
Note: When used as a vented heater, appli-
ance must be installed only in a solid-fuel
burning fireplace with a working flue and
constructed of noncombustible material.
Damper
Ifyourheaterisamanually-controlledmodel,
you may use this heater as a vented product.
There are three reasons for operating your
heater in the vented mode.
Manufactured Fireplace
Masonry Fireplace
Figure 10 - Attaching Damper Clamp
Installation Items Needed
• hardware package (provided with heater)
INSTALLING HEATER BASE
ASSEMBLY
1. The fireplace does not meet the clear-
ance to combustibles requirements for
vent-free operation.
• approved flexible gas hose (not provided)
(if allowed by local codes)
2. State or local codes do not permit vent-
free operation.
CAUTION: Do not remove the
dataplatesattachedtotheheater
base assembly. The data plates
contain important warranty and
safety information.
• sealant (resistant to propane/LP gas, not
provided)
3. You prefer vented operation.
• electric drill with 3/16" drill bit (metal
or masonry as applicable)
Ifreasons number 1 or 2 above apply toyou,
you must permanently open chimney flue
damper. You must install the damper clamp
accessory (to order, see Accessories, page
24). This will insure vented operation (see
Figure 10). The damper clamp will keep
damper open. Installation instructions are
included with clamp accessory.
• flathead screwdriver
WARNING: You must secure
this heater to fireplace floor. If
not, heater will move when you
adjust controls. Moving heater
may cause a gas leak.
1. Apply pipe joint sealant lightly to male
threads of the fitting to be threaded into
gas control. Connect approved flexible
gas hose to gas control fitting in heater
(see Figure 11, page 11).
See chart below for minimum permanent
flue opening you must provide. Attach
damper clamp so the minimum permanent
flue opening will be maintained at all times.
IMPORTANT: Hold gas fitting with
wrenchwhenconnectingflexiblegashose.
WARNING: If installing in a
sunken fireplace, special care is
needed. You must raise the fire-
place floor to allow access to
heater control panel. This will in-
sure adequate air flow and guard
against sooting. Raise fireplace
floor with noncombustible mate-
rial. Make sure material is secure.
2. Locate two masonry screws in hard-
ware package.
3. Place heater base in fireplace.
Area of Various Standard
Round Flues
4. Place logs in their proper position on
heater base (see Installing Logs, page 13).
Diameter (ins.) Area (sq. ins.)
5. Center heater base and logs front-to-
back and side-to-side in fireplace.
5"
6"
7"
8"
20 sq. inches
29 sq. inches
39 sq. inches
51 sq. inches
6. Carefully remove logs without moving
heater base.
CAUTION: Do not pick up
heater base assembly by the
burner. This could damage
heater. Only handle base assem-
bly by grates.
7. Mark screw locations through one hole
on each side of the mounting bracket
(see Figure 12, page 11). If installing
in a brick-bottom fireplace, mark screw
locations in mortar joint of bricks.
Chimney
Minimum Permanent
Height (ft.) Flue Opening (sq. ins.)
6' to 15'
15' to 30'
39 sq. inches
29 sq. inches
IMPORTANT:Makesuretheheaterburner
is level. If heater is not level, heater will not
work properly.
8. Remove heater base from fireplace. If
installing optional control accessories,
do so at this time. Follow all directions
provided with accessory.
105190
10
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
INSTALLING GWMS2
(OPTIONAL) WALL
MOUNTED SWITCH
CONNECTING TO GAS
SUPPLY
INSTALLATION
Continued
9. Drill holes at marked locations using
3/16" drill bit.
WARNING:Thisappliancere-
Items Included for Installation
• Switch
quires a 1/2" NPT (National Pipe
Thread) inlet connection to the
pressure regulator.
10. Attach base assembly to fireplace floor
using two masonry screws (in hardware
package).
• Switch Cover (With Screws)
• 25 Ft. Wire
WARNING:Aqualifiedservice
person must connect heater to
gassupply.Followalllocalcodes.
Connecting To Log Set
Flexible Gas
Hose (if allowed
by local codes)
1. Connect one terminal of 25 ft. wire to
bottom contact of switch located on
heater front control panel (see Figure 13).
Fitting
CAUTION: Never connect
heater directly to the propane/LP
supply. This heater requires an
externalregulator(notsupplied).
Install the external regulator be-
tweentheheaterandpropane/LP
supply.
2. Connect remaining wire terminal to the
“TH” terminal on the control valve (see
Figure 13).
3. Route the 25 ft. wire to a convenient
location.
Figure 11 - Attaching Flexible Gas Hose
to Heater
WARNING: Do not connect
the switch to a power source.
Electrical shock and/or fire haz-
ard will occur.
Masonry Screw
Installation Items Needed
Beforeinstallingheater,makesureyouhave
the items listed below.
• external regulator (supplied by installer,
see above)
IMPORTANT: The wire may be shortened
but must not be lengthened.
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection *
• sediment trap
4. Connect one bare wire end to each of
the terminals of the provided wall
switch.
AU
TO
O
F
F
O
N
L
O
I
H
L
O
O
F
F
N
O
T
L
I P
O
5. Install the wall switch and cover in the
wall.
Mounting
Flanges
• tee joint
• pipe wrench
Figure 12 - Attaching Base Assembly to
Fireplace Floor
Switch
* ACSAdesign-certifiedequipmentshutoff
valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Pur-
chase the optional CSA design-certified
equipment shutoff valve from your dealer.
See Accessories, page 24.
A
U
T
O
OFF
O
N
One
terminal
of 25 ft.
wire
To Wall
Switch
The installer must supply an external regu-
lator. The external regulator will reduce
incoming gas pressure. You must reduce
incominggaspressuretobetween11and14
inches of water. If you do not reduce incom-
ing gas pressure, heater regulator damage
could occur. Install external regulator with
the vent pointing down as shown in Figure
14,page12.Pointingtheventdownprotects
it from freezing rain or sleet.
To Wall
Switch
Wall Switch
Figure 13 - Connecting Wire Terminals
Continued
105190
11
Download from Www.Somanuals.com. All Manuals Search And Download.
VANGUARD
UNVENTED PROPANE/LP GAS LOG HEATER
Installation must include an equipment
INSTALLATION
CAUTION: Avoid damage to
control. Hold fitting with wrench
when connecting it to gas piping
and/or fittings.
shutoff valve, union, and plugged 1/8" NPT
tap. Locate NPT tap within reach for test
gauge hook up. NPT tap must be upstream
from heater (see Figure 15).
Continued
WARNING: Never connect
heater to private (non-utility) gas
wells. This gas is commonly
known as wellhead gas.
IMPORTANT:Installanequipmentshutoff
valve in an accessible location. The equip-
ment shutoff valve is for turning on or
shutting off the gas to the appliance.
CHECKING GAS
CONNECTIONS
WARNING: Test all gas pip-
ing and connections for leaks
after installing or servicing. Cor-
rect all leaks at once.
CAUTION: Use only new,
black iron or steel pipe. Inter-
nally-tinned copper tubing may
be used in certain areas. Check
yourlocalcodes.Usepipeof1/2"
diameter or greater to allow
proper gas volume to heater. If
pipe is too small, undue loss of
volume will occur.
Check your building codes for any special
requirementsforlocatingequipmentshutoff
valve to fireplace.
ApplypipejointsealantlightlytomaleNPT
threads. This will prevent excess sealant
from going into pipe. Excess sealant in pipe
could result in clogged heater valves.
WARNING:Neveruseanopen
flame to check for a leak. Apply a
noncorrosiveleakdetectionfluid
to all joints. Bubbles forming
show a leak. Correct all leaks at
once.
WARNING:Usepipejointseal-
ant that is resistant to liquid pe-
troleum (LP) gas.
External Regulator
Propane/LP
Supply
Tank
We recommend that you install a sediment
trap in supply line as shown in Figure 15.
Locate sediment trap where it is within
reach for cleaning. Install in piping system
betweenfuelsupplyandheater.Locatesedi-
ment trap where trapped matter is not likely
to freeze. A sediment trap traps moisture
and contaminants. This keeps them from
going into heater controls. If sediment trap
is not installed or is installed wrong, heater
may not run properly.
CAUTION: Make sure exter-
nal regulator has been installed
between propane/LP supply and
heater.SeeguidelinesunderCon-
necting to Gas Supply, pages 11
and 12.
Pressure Testing Gas Supply
Piping System
Test Pressures In Excess Of 1/2 PSIG
(3.5 kPa)
Vent Pointing Down
Figure 14 - External Regulator With Vent
Pointing Down
1. Disconnect appliance with its appliance
main gas valve (control valve) and equip-
ment shutoff valve from gas supply pip-
ing system. Pressures in excess of 1/2 psig
will damage heater regulator.
CSA Design-Certified Equipment
Shutoff Valve With 1/8" NPT Tap*
Approved Flexible Gas Hose
(if allowed by local codes)
From External
Regulator (11"
W.C.** to 14"
W.C. Pressure)
2. Cap off open end of gas pipe where
equipment shutoff valve was connected.
Gas Control
3. Pressurize supply piping system by ei-
ther using compressed air or opening
propane/LP supply tank valve.
Tee Joint
Sediment
4. Check all joints of gas supply piping
system. Apply a noncorrosive leak de-
tection fluid to gas joints. Bubbles
forming show a leak.
3" Minimum
Pipe Nipple
Trap
Cap
5. Correct all leaks at once.
6. Reconnect heater and equipment
shutoff valve to gas supply. Check re-
connected fittings for leaks.
Figure 15 - Gas Connection
*PurchasetheoptionalCSAdesign-certifiedequipmentshutoffvalvefromyourdealer.See
Accessories, page 24.
** Minimum inlet pressure for purpose of input adjustment.
105190
12
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
Equipment Shutoff
Valve
INSTALLATION
Control Valve Location
Propane/LP
Supply Tank
Continued
Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see
Figure 16).
2. Pressurize supply piping system by ei-
ther using compressed air or opening
propane/LP supply tank valve.
3. Check all joints from propane/LP sup-
ply tank to equipment shutoff valve (see
Figure 17). Apply a noncorrosive leak
detection fluid to gas joints. Bubbles
forming show a leak.
4. Correct all leaks at once.
Figure 17 - Checking Gas Joints
Pressure Testing Heater Gas
Connections
INSTALLING LOGS
One Piece Log Set
1. Open equipment shutoff valve (see Fig-
ure 16).
WARNING: Failure to position
thepartsinaccordancewiththese
diagrams or failure to use only
parts specifically approved with
this heater may result in property
damage or personal injury.
2. Open propane/LP supply tank valve.
3. Make sure control knob of heater is in
the OFF position.
4. Check all joints from equipment shutoff
valve to control valve (see Figure 17).
Apply a noncorrosive leak detection
fluid to gas joints. Bubbles forming
show a leak.
CAUTION: After installation
andperiodicallythereafter,check
to ensure that no flame comes in
contact with any log. With the
heater set to High, check to see if
flames contact any log. If so, re-
position logs according to the
loginstallationinstructionsinthis
manual. Flames contacting logs
will create soot.
Burner
AU
O
ON
TO
FF
I
5. Correct all leaks at once.
L
I
H
L
O
O
F
F
N
O
T
L
I P
O
6. Light heater (see Operating Heater,
pages 14 through 16). Check all other
internal joints for leaks.
"U"-shaped
Cutout in
Chassis
Chassis
Figure 18 - Installing Vintage Oak One-
Piece Log Set
7. Turn off heater (see To Turn Off Gas to
Appliance, page 15).
Burner
Ports
One Piece Log Set
Equipment
Shutoff
Valve
Open
Itisveryimportanttoinstallthelogsexactly
as instructed. Do not modify logs. Only use
logs supplied with heater.
1. Place one-piece log set on grate to fit
as illustrated in Figure 18. Make sure
middle section at bottom of log set is
seated into “U”-shaped cutout in cen-
ter of chassis (see Figure 18). Log will
fit securely on chassis. IMPORTANT:
Make sure log does not cover any
burner ports.
Closed
Figure 16 - Equipment Shutoff Valve
Figure 19 - Installing Vintage Oak One-
Piece Log set (Top View)
2. Place lava rock around base of heater.
105190
13
Download from Www.Somanuals.com. All Manuals Search And Download.
VANGUARD
UNVENTED PROPANE/LP GAS LOG HEATER
LIGHTING
INSTRUCTIONS
OPERATING
WARNING: Burner will come
on automatically within one
minute when the selector switch
is in the ON position after the
pilot is lit.
HEATER
WARNING:
FOR YOUR SAFETY
READ BEFORE
LIGHTING
• If fireplace has glass doors,
never operate this heater with
glassdoorsclosed.Ifyouoper-
ate heater with doors closed,
heatbuildupinsidefireplacewill
cause glass to burst. Also if
fireplace opening has vents at
the bottom, you must open the
vents before operating heater.
• You must operate this heater
withafireplacescreeninplace.
Make sure fireplace screen is
closed before running heater.
4. Press in and turn control knob clock-
wise
to the OFF position.
WARNING: If you do not fol-
low these instructions exactly, a
fireorexplosionmayresultcaus-
ing property damage, personal
injury or loss of life.
5. Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation, column 1. If you don’t
smell gas, go to the next step.
A. This appliance has a pilot which must
be lighted by hand. When lighting the
pilot, follow these instructions exactly.
6. Press in and turn control knob coun-
terclockwise
to the PILOT
position. Press in control knob for
five (5) seconds (see Figure 20).
B. BEFORE LIGHTING smell all
around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.
NOTICE: During initial operation
of new heater, burning logs will
give off a paper-burning smell.
Open damper or window to vent
smell.Thiswillonlylastafewhours.
Note: You may be running this
heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds or more. This will al-
low air to bleed from the gas system.
WHAT TO DO IF YOU SMELL
GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do
Note: Home owners generally prefer to
operate their heater with the chimney
not use any phone in your building. damper closed. This will put all the heat
7. With control knob pressed in, press
and release ignitor button. This will
light pilot. The pilot is attached to the
front burner. If needed, keep press-
ing ignitor button until pilot lights.
into the room. However, there may be
times you will desire the full flames of the
HI heat setting but will find the heat
output excessive. You can open the chim-
ney damper (if you have one) fully or
partially to release some of the heat.
• Immediately call your gas supplier
from a neighbor’s phone. Follow
the gas supplier’s instructions.
• If you cannot reach your gas sup-
plier, call the fire department.
Note: If pilot does not stay lit, con-
tact a qualified service person or gas
supplier for repairs. Until repairs are
made, light pilot with match. To light
pilot with match, see Manual Light-
ing Procedure, page 15.
C. Use only your hand to push in or turn
the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.
WARNING: Damper handle
will be hot if heater has been
running.
1. STOP! Read the safety information,
column 1.
D. Do not use this appliance if any part
has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been un-
der water.
2. Make sure equipment shutoff valve
is fully open.
3. Set switch in OFF position.
Flame Adjustment Knob
Control Knob
AUTO
OFF
ON
O
O
O
Ignitor Button
Selector Switch
Figure 20 - Control Knob and Ignitor Button Location (Shown as Supplied,
No Control Options)
105190
14
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
For wall thermostat operation, follow in-
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
1. Turn control knob clockwise
to the OFF position.
OPERATING
struction supplied with thermostat acces-
sory GWMT1. For wall switch operation
followinstructionssuppliedwithGWMS2.
HEATER
Continued
8. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
• If control knob does not pop out
when released, contact a qualified
service person or gas supplier for
repairs.
NOTICE: You must light the pilot
before using the hand-held re-
mote control unit. See Lighting
Instructions on page 14.
2a. Set selector switch in the OFF position.
2b. If Using Optional Hand-Held Re-
mote: Set selector switch in the OFF
position to prevent draining battery.
1. After lighting, let pilot flame burn for
about one minute. Turn control knob
to ON position. Adjust flame adjust-
ment knob anywhere between HI
and LO. Slide the selector switch to
the REMOTE position. Note: The
burner may light if hand-held remote
ON button was on when selector
switch was last turned off. You can
now turn the burner on and off with
the hand-held remote control unit.
Shutting Off Burner Only (pilot
stays lit)
Note: If pilot goes out, repeat steps
4 through 8.
Youmayshutofftheburnerandkeepthe
pilot lit by doing one of the following:
9. Slightly push in and turn control
knob counterclockwise
ON position.
to the
1. Turn control knob clockwise
to the PILOT position.
10. Wait one minute and switch selector
switch to the ON position to light
burner. Note:AUTO is only functional
when using GWMT1 or GWMS2 op-
tional accessories.
2. UseremotecontrolmanualOFFbutton.
3. Set selector switch in the OFF position.
IMPORTANT: Do not leave the se-
lector switch in the REMOTE posi-
tion when the pilot is not lit. This will
drain the battery.
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 6 under Light-
11. Set flame adjustment knob to any
level between HI and LO.
IMPORTANT: Be sure to press the
ON/OFF buttons on the hand-held
remote control unit for up to 3 sec-
onds to assure proper operation.
ing Instructions, page 14.
CAUTION:Donottrytoadjust
heatinglevelsbyusingtheequip-
ment shutoff valve.
2. Depress control knob and light pilot
with match.
3. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
GHRC Series Operation:
WARNING: Make sure the
selector switch is in the OFF po-
sition when you are away from
home for long periods of time.
Heater will come on automati-
cally with selector switch in the
ON position.
seconds, release control knob. Now 2a. Press ON/OFF button to turn the
follow steps 9 through 11, column 1.
burner on and off. When turning
burner off, the pilot will remain lit.
OPTIONAL REMOTE
OPERATION
GHRCTA Series Operation:
2b. Press the AUTO/ON/OFF button on
the hand-held remote control (see
Figure 22, page 16). The lights to the
left of the button will show AUTO,
ON, or OFF.
Note:Allremotecontrolaccessoriesmust
bepurchasedseparately(seeAccessories,
page 24). Follow instructions included
with the remote control.
Pilot Burner
Ignitor
Electrode
• In the ON mode, the burners will
ignite. The heater is in manual
mode when ON is lit.
Thermostat Control Operation
(Optional GHRCTA Series Only) The
thermostat control setting on the remote
control unit can be set to any comfort
level between WARMER and COOLER.
The burners will turn on and off auto-
matically to maintain the comfort level
you select. The ideal comfort setting will
vary by household depending upon the
amount of space to be heated, the output
of the central heating system, etc.
• In theAUTO mode, the thermostat
in the hand-held remote unit con-
trols the room temperature. To in-
crease the room temperature, press
the top arrow of the TEMP button.
To lower the room temperature,
press the bottom arrow of the
TEMP button. At higher settings
the heater will run longer.
Figure 21- Pilot
Continued
105190
15
Download from Www.Somanuals.com. All Manuals Search And Download.
VANGUARD
UNVENTED PROPANE/LP GAS LOG HEATER
Pilot Burner
OPERATING
INSPECTING
BURNERS
Thermocouple
HEATER
Continued
Check pilot flame pattern and burner flame
patterns often.
IMPORTANT:This remote control
has been specially engineered to
take an air temperature sample ev-
ery 5.5 minutes in the auto mode.
It will not respond immediately to
the temperature setting being
turned up or down.
IMPORTANT: The hand-held re-
mote control unit must be near the
heater. Do not keep the hand-held
remote control unit too close to the
heater. The thermostat on the
hand-held remote control unit will
heat up too quickly and turn the
heater off.
PILOT FLAME PATTERN
Figure 24 - Correct Pilot Flame Pattern
Figure 24 shows a correct pilot flame pat-
tern. Figure 25 shows an incorrect pilot
flame pattern. The incorrect pilot flame is
not properly heating the thermocouple.
When the thermocouple cools, the heater
will shut down.
Pilot Burner
Thermocouple
If pilot flame pattern is incorrect, as shown
in Figure 25
Figure 25 - Incorrect Pilot Flame Pattern
• turn heater off (see To Turn Off Gas to
Appliance, page 15)
BURNER PRIMARY AIR HOLES
• see Troubleshooting, pages 17 through 19
Air is drawn into the burner through the
holes in the fitting at the burner entrance.
These holes may become blocked with dust
or lint. Periodically inspect these holes for
any blockage and clean if needed. Blocked
air holes will create soot.
3. To turn the burner off, press the
AUTO/ON/OFF button until OFF
lights. The pilot will remain lit.
IMPORTANT: To turn the pilot off,
manually turn the control knob on the
heater to the OFF position.
MAIN BURNER
Flame Adjustment Knob
Periodically inspect all burner flame holes
with the heater running. All slotted burner
flame holes should be open with yellow
flame present. All round burner flame holes
should be open with a small blue flame
present. Some burner flame holes may be-
comeblockedbydebrisorrust,withnoflame
present. If so, turn off heater and let cool.
Remove blockage. Blocked burner flame
holes will create soot.
Control Knob in
On Position
P
F
ON
OFF
REMOTE
O
Selector Switch in Remote Position
(Optional Remote Control)
Figure 22 - Setting the Selector Switch, Control Knob, and Flame Adjustment Knob for
Remote Operation
Increases Room
Temperature in
AUTO Mode
Shows Temperature Setting
Decreases Room
Temperature in
AUTO Mode
The Log Heater will
Automatically Cycle
between Pilot and the
Heat Setting that has
been Selected
Turns Burners
On or Off and
Allows You to
Choose the Auto
Setting
Figure 23 - Thermostat Hand-Held Remote Control Unit Selections (GHRCTA Series
only)
105190
16
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
TROUBLESHOOTING
Note: For additional help, visit DESA
International’stechnicalservicewebsite
WARNING: Turn off heater
CAUTION: Never use a wire,
needle, or similar object to clean
ODS/pilot.ThiscandamageODS/
pilot unit.
and let cool before servicing.
Only a qualified service person
should service and repair
heater.
Note:Alltroubleshootingitemsarelistedin
order of operation.
OBSERVED PROBLEM
POSSIBLE CAUSE
REMEDY
When ignitor button is pressed, there is no
spark at ODS/pilot
1. Ignitor electrode not connected to igni- 1. Reconnect ignitor cable
tor cable
2. Ignitor cable pinched or wet
2. Free ignitor cable if pinched by any
metal or tubing. Keep ignitor cable dry
3. Tighten nut holding piezo ignitor to base
panel of log set. Nut is located behind
base panel
3. Piezo ignitor nut is loose
4. Broken ignitor cable
4. Replace ignitor cable
5. Bad piezo ignitor
5. Replace piezo ignitor
6. Ignitor electrode broken
6. Replace piezo ignitor
7. Ignitor electrode positioned wrong
7. Replace piezo ignitor
When ignitor button is pressed, there is
spark at ODS/pilot but no ignition
1. Gas supply turned off or equipment 1. Turn on gas supply or open equipment
shutoff valve closed
shutoff valve
2. Control knob not in PILOT position
3. Control knob not pressed in while in
PILOT position
2. Turn control knob to PILOT position
3. Press in control knob while in PILOT
position
4. Air in gas lines when installed
4. Continue holding down control knob.
Repeat igniting operation until air is re-
moved
5. Depleted gas supply
6. ODS/pilot is clogged
5. Contact local propane/LP gas company
6. Clean ODS/pilot (see Cleaning and
Maintenance, page 21) or replace ODS/
pilot assembly
7. Gas regulator setting is not correct
1. Control knob not fully pressed in
7. Replace gas control
ODS/pilot lights but flame goes out when
control knob is released
1. Press in control knob fully
2. Control knob not pressed in long enough 2. After ODS/pilot lights, keep control
knob pressed in 30 seconds
3. Equipment shutoff valve not fully open 3. Fully open equipment shutoff valve
4. Pilot flame not touching thermocouple, 4. A) Contact local propane/LP gas company
which allows thermocouple to cool,
causing pilot flame to go out. This prob-
lem could be caused by one or both of
the following:
B) Clean ODS/pilot (see Cleaning and
Maintenance, page 21) or replace ODS/
pilot assembly
A) Low gas pressure
B) Dirty or partially clogged ODS/pilot
5. Thermocouple connection loose at con- 5. Hand tighten until snug, then tighten
trol valve
1/4 turn more
6. Thermocouple damaged
6. Replace thermocouple
7. Control valve damaged
7. Replace control valve
Continued
105190
17
Download from Www.Somanuals.com. All Manuals Search And Download.
VANGUARD
UNVENTED PROPANE/LP GAS LOG HEATER
TROUBLESHOOTING
Continued
OBSERVED PROBLEM
POSSIBLE CAUSE
REMEDY
Burner does not light after ODS/pilot is lit
1. Burner orifice clogged
1. Clean burner (see Cleaning and Mainte-
nance, page 21) or replace burner orifice
2. Contact local propane/LP gas company
3. Replace burner orifice
2. Inlet gas pressure is too low
3. Burner orifice diameter is too small
4. Thermopile leads disconnected or im- 4. Reconnect leads (see Wiring Diagram,
properly connected page 20)
5. Burners will not come on in remote po- 5. Replace battery in transmitter and re-
sition
ceiver
Delayed ignition burner
1. Manifold pressure is too low
2. Burner orifice clogged
1. Contact local propane/LP gas company
2. Clean burner (see Cleaning and Mainte-
nance, page 21) or replace burner orifice
Burner backfiring during combustion
1. Burner orifice is clogged or damaged
1. Clean burner (see Cleaning and Mainte-
nance, page 21) or replace burner orifice
2. Replace damaged burner
2. Damaged burner
3. Gas regulator defective
3. Replace gas control
Slight smoke or odor during initial operation 1. Not enough air
1. Check burner for dirt and debris. If
found, clean burner (see Cleaning and
Maintenance, page 21)
2. Gas regulator defective
2. Replace gas control
3. Residues from manufacturing processes 3. Problem will stop after a few hours of
and logs curing
operation
Moisture/condensationnoticedonwindows 1. Not enough combustion/ventilation air
1. Refer to Air for Combustion and Venti-
lation requirements (page 4)
Heater produces a whistling noise when 1. Turning control knob to HI position 1. Turn control knob to LO position and
burner is lit
when burner is cold
2. Air in gas line
let warm up for a minute
2. Operate burner until air is removed from
line. Have gas line checked by local pro-
pane/LP gas company
3. Air passageways on heater blocked
3. Observe minimum installation clear-
ances (see pages 7 through 9)
4. Dirty or partially clogged burner orifice 4. Clean burner (see Cleaning and Mainte-
nance, page 21) or replace burner orifice
Whitepowderresidueformingwithinburner 1. When heated, vapors from furniture pol- 1. Turn heater off when using furniture
box or on adjacent walls or furniture
ish, wax, carpet cleaners, etc. may turn
polish, wax, carpet cleaners or similar
into white powder residue
products
Remote does not function (GHRC Series 1. Battery is not installed. Battery power 1. Replace 9-volt batteries in receiver and
and GHRCTA Series only) is low remote control
105190
18
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
TROUBLESHOOTING
Continued
WARNING: If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your
building.
• Immediatelycallyourgassupplierfromaneighbor’sphone.Followthe
gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning
supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles,
etc., createfumes. Thesefumesmaymixwithcombustionairandcreateodors. Theseodors
will disappear over time.
OBSERVED PROBLEM
POSSIBLE CAUSE
REMEDY
Heater produces a clicking/ticking noise 1. Metal expanding while heating or con-
1. This is common with most heaters. If
noise is excessive, contact qualified ser-
vice person
just after burner is lit or shut off
tracting while cooling
Heater produces unwanted odors
1. Heater burning vapors from paint, hair
spray, glues, cleaners, chemicals, new
carpet, etc. (See IMPORTANT state-
ment above)
1. Open window and ventilate room. Stop
using odor causing products while heater
is running
2. Gas leak. SeeWarning statement at
top of page
2. Locate and correct all leaks (see Check-
ing Gas Connections, pages 12 and 13)
Heater shuts off in use (ODS operates)
1. Not enough fresh air is available
2. Low line pressure
3. ODS/pilot is partially clogged
1. Open window and/or door for ventilation
2. Contact local propane/LP gas company
3. Clean ODS/pilot (see Cleaning and
Maintenance, page 21)
Gas odor even when control knob is in OFF 1. Gas leak. SeeWarning statement at
1. Locate and correct all leaks (see Check-
ing Gas Connections, pages 12 and 13)
2. Replace control valve
position
top of page
2. Control valve defective
Gas odor during combustion
1. Foreign matter between control valve
and burner
2. Gas leak. SeeWarning statement at
top of page
1. Take apart gas tubing and remove for-
eign matter
2. Locate and correct all leaks (see Check-
ing Gas Connections, pages 12 and 13)
105190
19
Download from Www.Somanuals.com. All Manuals Search And Download.
VANGUARD
UNVENTED PROPANE/LP GAS LOG HEATER
WIRING DIAGRAM
REPLACEMENT
PARTS
Note: Use only original replacement parts.
Thiswillprotectyourwarrantycoveragefor
parts replaced under warranty.
Note: For proper operation of optional ac-
cessories, the wires from the switch to the
controlmustbeconnectedexactlyasshown.
PARTS UNDER WARRANTY
Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), call DESA International’s Techni-
cal Service Department at 1-866-672-6040.
When calling DESA International, have
ready
AUT
O
O
FF
O
N
• your name and address
• model and serial numbers of your heater
• how heater was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date
Thermopile
SPECIFICATIONS
Usually, we will ask you to return the part to
the factory.
Vintage Oak
Vintage Oak
24” and 30”
18"
PARTS NOT UNDER
WARRANTY
Btu (Variable)
Type Gas
Ignition
Pressure Manifold
Inlet Gas Pressure (in. of water)
Maximum
Minimum*
Shipping Weight
17,500/27,000
Propane/LP Only
Piezo
19,000/31,500
Propane/LP Only
Piezo
8.0" W.C.
Contact authorized dealers of this prod-
uct. If they can’t supply original replace-
ment part(s), call DESA International at
1-866-672-6040 for referral information.
WhencallingDESAInternational,haveready
8.0" W.C.
14"
11"
28 lbs.
14"
11"
30 lbs. (24")/32 lbs. (30")/
• model number of your heater
• the replacement part number
* For input adjustment
SERVICE HINTS
When Gas Pressure Is Too Low
• pilot will not stay lit
TECHNICAL
SERVICE
You may have further questions about in-
stallation, operation, or troubleshooting. If
so, contact DESA International’s Technical
Service Department at 1-866-672-6040.
• burners will have delayed ignition
• heater will not produce specified heat
• propane/LP gas supply may be low
You can also visit DESA International’s
technical services web site at
You may feel your gas pressure is too low.
If so, contact your local propane/LP gas
supplier.
105190
20
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
4. Check the injector holder located at the
LOGS
CLEANING AND
MAINTENANCE
end of the burner tube again. Remove
any large particles of dust, dirt, lint, or
pet hair with a soft cloth or vacuum
cleaner nozzle.
• If you remove logs for cleaning, refer to
Installing Logs, page 13, to properly re-
place logs.
WARNING: Turn off heater
and let cool before cleaning.
• Replace log(s) if broken or chipped
(dime-sized or larger).
5. Blow air into the primary air holes on
the injector holder.
6. In case any large clumps of dust have MAIN BURNER
CAUTION: You must keep
control areas, burner, and circu-
lating air passageways of heater
clean. Inspect these areas of
heater before each use. Have
heaterinspectedyearlybyaquali-
fied service person. Heater may
needmorefrequentcleaningdue
to excessive lint from carpeting,
bedding material, pet hair, etc.
now been pushed into the burner repeat
Periodically inspect all burner flame holes
steps 3 and 4.
with the heater running. All slotted burner
flame holes should be open with yellow
flame present. All round burner flame holes
should be open with a small blue flame
present. Some burner flame holes may be-
come blocked by debris or rust, with no
flame present. If so, turn off heater and let
cool. Remove blockage. Blocked burner
flame holes will create soot.
Clean the pilot assembly also. A yellow tip
on the pilot flame indicates dust and dirt in
the pilot assembly. There is a small pilot air
inlet hole about two inches from where the
pilot flame comes out of the pilot assembly
(see Figure 27). With the unit off, lightly
blow air through the air inlet hole. You may
blowthroughadrinkingstrawifcompressed
air is not available.
Injector Holder
CLEANING BURNER
INJECTOR HOLDER AND
PILOT AIR INLET HOLE
(May Be Brass
or Aluminum
Depending on
Burner
Tube
Model)
The primary air inlet holes allow the proper
amount of air to mix with the gas. This
provides a clean burning flame. Keep these
holes clear of dust, dirt, lint and pet hair.
Clean these air inlet holes prior to each
heating season. Blocked air holes will cre-
ate soot. We recommend that you clean the
unit every three months during operation
and have heater inspected yearly by a quali-
fied service person.
Primary Air Inlet
Holes (Shape of
Holes May Vary
by Model)
Figure 26 - Injector Holder On Outlet
Burner Tube
Wealsorecommendthatyoukeeptheburner
tube and pilot assembly clean and free of
dustanddirt.Tocleanthesepartswerecom-
mend using compressed air no greater than
30 PSI. Your local computer store, hard-
ware store, or home center may carry com-
pressed air in a can. You can use a vacuum
cleaner in the blow position. If using com-
pressed air in a can, please follow the direc-
tions on the can. If you don't follow direc-
tionsonthe can, youcoulddamage the pilot
assembly.
Ports/Slots
Burner
Tube
Pilot
Assembly
Pilot Air
Inlet Hole
1. Shut off the unit, including the pilot.
Allow the unit to cool for at least thirty
minutes.
2. Inspect burner, pilot, and primary air
inlet holes on injector holder for dust
and dirt (see Figure 26).
3. Blow air through the ports/slots and
holes in the burner.
Figure 27 - Pilot Inlet Air Hole
105190
21
Download from Www.Somanuals.com. All Manuals Search And Download.
VANGUARD
UNVENTED PROPANE/LP GAS LOG HEATER
ILLUSTRATED
PARTS
BREAKDOWN
VINTAGE OAK LOG MODELS
VYS18PWA, VYS24PWA,
VYS30PWA
1
2
10
7
9
3
6
4
8
5
10
12
11
13
23
I
H
L
O
O
F
F
N
O
T
I P
O
L
18
14
17
13
15
19
16
24
19
20
22
I
H
L
O
O
F
N
F
O
T
I P
O
L
13
21
105190
22
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
This list contains replaceable parts used in your heater. When ordering parts, follow the
instructions listed under Replacement Parts on page 20 of this manual.
PARTS LIST
VINTAGE OAK LOG MODELS
VYS18PWA, VYS24PWA,
VYS30PWA
KEY
PART NUMBER FOR
NO.
VYS18PWA
VYS24PWA
VYS30PWA
DESCRIPTION
QTY.
1
2
3
4
5
6
7
8
105185-01
103778-01
098249-01
105197-02
098265-02
102843-01
099056-21
–
102963-01
099387-13
103781-02
103345-02
M11084-38
102775-10CK
098271-10
102445-01
103587-02CK
104099-01
098304-01
103784-02
103784-01
M12461-26
105185-02
103778-01
098249-01
105197-02
098265-02
102843-01
099056-19
102966-01
102773-01
099387-09
103781-02
103345-01
M11084-38
105185-03
103778-01
098249-01
105197-02
098265-02
102843-01
099056-19
102966-01
102773-01
099387-09
103781-02
103345-01
M11084-38
Log, 1 Piece
ODS Pilot (LP)
ODS Nut
Burner Outlet Tube
Elbow Connector
Burner Clip
Burner Orifice Injector
Upper Bracket
Burner
1
1
2
1
1
1
1
1
1
1
1
1
7
1
1
1
1
1
2
1
1
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Pilot Tube
Gas Control Valve
Lower Bracket
Screw, #8 x .38
Painted Base Assy
Ignitor Cable
Piezo Ignitor
Plate, Switch
Heat Shield
102775-06CK 102775-06CK
098271-10
102445-01
098271-10
102445-01
103587-02CK 103587-02CK
104099-01
098304-01
103784-02
103784-01
M12461-26
104099-01
098304-01
103784-02
103784-01
M12461-26
Screw
Flame Adjustment Knob
Off-Pilot-On Knob
Screw, Hex Slt Wsr
10-32 x .38
Wiring Harness
Switch
4
1
23
24
103284-02
099998-01
103284-02
099998-01
103284-02
099998-01
PARTS AVAILABLE — NOT SHOWN
100563-01
103877-01
100563-01
103877-01
100563-01
103877-01
Warning Plate
Lighting Instructions
Plate
Warning Plate Fastener
Caution Decal
Hardware Kit
1
1
1
1
1
1
100565-01
100693-01
101137-02
GA6060
100565-01
100639-01
101137-02
GA6060
100565-01
100639-01
101137-02
GA6060
Lava Rock
105190
23
Download from Www.Somanuals.com. All Manuals Search And Download.
VANGUARD
UNVENTED PROPANE/LP GAS LOG HEATER
DAMPER CLAMP - GA6080
(Not Shown)
W
ARMER
ACCESSORIES
COOLER
TEMP
AU
T
ON
OFF
O
Purchase these heater accessories from
your local dealer. If they can not supply
these accessories, call DESA International
at 1-866-672-6040 for referral informa-
tion. You can also write to the address
listed on the back page of this manual.
Permanently opens chimney flue damper
for vented operation. Can be used only with
non-thermostat accessories.
LAVA ROCK - GA6060
(Not Shown)
RECEIVER AND HAND-HELD
THERMOSTAT REMOTE CON-
TROL KIT - GHRCTA SERIES
For all models. Order when additional rock
is desired. (2 lb. bag)
WALL-MOUNT THERMOSTAT
SWITCH - GWMT1
(Not Shown)
For all models. Allows the gas log heater to
be operated in a manually or thermostati-
cally-controlled mode. You can turn the gas
log heater on and off without ever leaving
the comfort of your easy chair.
For all models. The desired comfort setting
can be selected on the wall thermostat and
the log heater will automatically cycle from
pilot to the heat setting selected.
EQUIPMENT SHUTOFF
VALVE - GA5010
For all models. Equipment shutoff valve
with 1/8" NPT tap. Fits 1/2" NPT pipe.
WALL MOUNTED SWITCH
KIT - GWMS2
(Not Shown)
For all models. Allows convenient access
to the operation of your gas log heater.
INFORMATION VIDEO
108917-01
RECEIVER AND HAND-
HELD REMOTE CONTROL
KIT - GHRC SERIES
FIREPLACE HOOD
Black - GA6050
Brass - GA6052
For all models. A care and maintenance
videoisavailablebycalling1-866-672-6040.
Antique Brass - GA6053
For all models. Allows the gas log heater
to be turned on and off by using a hand-
held remote control.
For all models. Helps deflect heat away
from mantel or wall above fireplace. Fits
openings 28" to 48" wide.
105190
24
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
NOTES
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
105190
25
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY INFORMATION
KEEP THIS WARRANTY
Model
Serial No.
Date Purchased
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other
warranty, expressed or implied.
LIMITED WARRANTY
VENT-FREE PROPANE/LP GAS LOG HEATERS
DESA International warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided
that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty
the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating
conditionandanallowanceforlaborwhenprovidedbyaDESAAuthorizedServiceCenter.Warrantypart(s)MUSTbeobtainedthroughauthorizeddealers
of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this
warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result
of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all
such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS
WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED
WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO FOUR (4) YEARS
ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO
THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES
WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the
above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty write:
TM
2701 Industrial Drive
P.O. Box 90004