UNVENTED (VENT-FREE) LogMate® UNiVERSaL FiREBOX
OWNER’S OPERaTiON aND iNSTaLLaTiON MaNUaL
MODEL FBST
36" See-Thru Heat-Circulating Firebox
WARNING: If the information in these instructions is
not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
FOR YOUR SAFETY
— Do not store or use gasoline or any other flammable
vapors or liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS :
• Do not try to light any appliance.
• Do not touch any electrical switch;
• Do not use any phone in your building.
• Immediatelycallyourgassupplierfromaneighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
Save this manual for future reference.
Download from Www.Somanuals.com. All Manuals Search And Download.
SaFETy iNFORMaTiON
Carefully supervise young chil-
dren when they are in the room
with firebox.
IMPORTANT: Read this owner’s
manual carefully and completely
beforetryingtoassemble,operate
or service this firebox. Improper
use of this firebox can cause se-
rious injury or death from burns,
fire,explosion,electricalshockor
carbon monoxide poisoning.
You must operate this fireplace
with the provided fireplace
screen, hood and brick liner in
place. Make sure these parts
are in place and screens are
closed before running firebox.
The supplied hoods may not be
replaced with hoods which may
be provided with a log heater.
CAUTION: Carefully review
the instructions supplied with
the decorative type unvented
room heater for the minimum
firebox size requirement. Do not
install the appliance in this fire-
boxunlessthisfireboxmeetsthe
minimum dimensions required
for the installation.
Keep the appliance area clear
and free from combustible ma-
terials, gasoline and other flam-
mable vapors and liquids.
1. This firebox shall not be installed in a bedroom
or bathroom.
2. Never install the firebox
• in a recreational vehicle
WARNING: Any change to
this firebox or its controls can
be dangerous.
• where curtains, furniture, clothing or other
flammable objects are less than 42" from the
front, top or sides of the firebox
• in high traffic areas
• in windy or drafty areas
WARNING:Donotuseablow-
er insert, heat exchanger insert
orotheraccessorynotapproved
for use with this firebox.
3. Do not use this firebox as a wood-burning
fireplace. Use only decorative unvented room
heaters (log sets).
4. Do not add extra logs or ornaments such as
pine cones, vermiculite or rock wool. Using
these added items can cause sooting.
Donotallowfanstoblowdirectly
intothefirebox.Avoidanydrafts
that alter burner flame patterns.
Ceiling fans can create drafts
that alter burner flame patterns.
Altered burner patterns can
cause sooting.
5. Use only the provided hoods or appropriate
polished brass hood accessories. See Acces-
sories on page 18.
6. Vent-freegaslogheatersinstalledinthisfirebox
require fresh air ventilation to run properly. See
Air for Combustion and Ventilation, page 5.
7. Do not run firebox
• where flammable liquids or vapors are used
or stored
• under dusty conditions
Firebox front and screen be-
comes very hot when running
firebox.Keepchildrenandadults
away from hot surfaces to avoid
burns or clothing ignition. Fire-
box will remain hot for a time
after shutdown. Allow surfaces
to cool before touching.
8. Do not use this firebox to cook food or burn
paper or other objects.
9. Never place any objects in firebox or on logs.
10. Turn firebox off and let cool before servicing.
Only a qualified service person should service
and repair firebox.
11. Operatingvent-freelogsinafireboxaboveeleva-
tions of 4,500 feet could cause pilot outage.
105116-01D
3
Download from Www.Somanuals.com. All Manuals Search And Download.
BLOWER ACCESSORY
SaFETy iNFORMaTiON
The FBST firebox will accept the GA3500A ac-
cessory. The variable blower allows you to select
the fan speed you desire. The blower circulates
heated air from the firebox into the room. Use of
blower is optional.
Continued
12. Do not use the firebox if it has been under water
due to the shock hazard that could result with
the blower accessary (if installed) in place.
13. Provide adequate clearances around air
openings.
BRICK LINER
This firebox features a concrete brick liner. As
with all concrete liners, this liner may develop
slight cracks when exposed to heat. These cracks
will not affect the performance of the firebox or
vent-free gas logs.
LOCaL CODES
Install and use firebox with care. Follow all local
codes. In the absence of local codes, use the lat-
est edition of The National Fuel Gas Code ANS
Z223.1/NFPA 54*. Firebox must be electrically
grounded in accordance with the National Electri-
cal Code, ANS/NFPA70 (latest edition).
PRODUCT
SPECiFiCaTiONS
*Available from:
1 1/4"
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
24"
1/2"
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
5/8"
UNPaCkiNg
1. Remove all protective packaging from inside
firebox. Carefully lift the firebox off the bot-
tom corrugated tray.
4 1/4"
1 3/4"
3" TYP.
2. Carton should contain 2 deflective hoods
and hardware packet in addition to firebox
assembly. If items are missing, inform dealer
where you bought firebox.
20 1/2"
40"
18 1/2"
36 1/4"
3. Check all items for any shipping damage. If
damaged, promptly inform dealer where you
bought firebox.
9 1/8"
36 1/2"
42 1/2"
44 1/4"
NOTICE: The firebox identifica-
tion label (including model num-
ber, serial number, clearances,
etc.) is located directly above
thebricklinerandundertheheat
shield. See Figure 20, page 15.
3 5/8"
4"
PRODUCT FEaTURES
OpERATION
19 1/2"
This firebox is designed for use with approvedANS
Z21.11.2 decorative type unvented room heaters.
(Physical size limitations apply. Refer to minimum
firebox requirements supplied with log heater.) It
requires no outside venting or chimney making in-
stallation easy and inexpensive. When used without
the blower, the firebox requires no electricity mak-
ing it ideal for emergency backup heat.
5 1
/
5
2 1/4"
12"
Figure 1 - Dual-Sided Firebox
4
105116-01D
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCaTiNg FiREBOX
pLANNING
Plan where you will install the firebox. This will
save time and money later when you install the fire-
box. Before installation, consider the following:
aiR FOR COMBUSTiON
aND VENTiLaTiON
WARNING:Thisfireboxshall
not be installed in a confined
space or unusually tight con-
struction unless provisions are
provided for adequate combus-
tionandventilationair. Readthe
following instructions to insure
proper fresh air for this and
other fuel-burning appliances
in your home.
1. Where the firebox will be located. Allow for
wall and ceiling clearances (see Installation
Clearances, page 8).
2. Everything needed to complete installation.
3. These models CANNOT be installed in a
bedroom or bathroom.
4. Proper air for combustion and ventilation.
5. Consider a location where heat output would
not be affected by drafts, air condition ducts,
windows or doors.
Today’s homes are built more energy efficient
than ever. New materials, increased insulation and
new construction methods help reduce heat loss
in homes. Home owners weather strip and caulk
around windows and doors to keep the cold air out
and the warm air in. During heating months, home
owners want their homes as airtight as possible.
6. Alocation that minimizes modifications on ex-
isting framing will make installation easier.
Projected installations can extend any dis-
tance into the room.Aprojection may be ideal
as a partition between two otherwise common
areas when added to an existing, finished wall
(see Figure 2).
While it is good to make your home energy effi-
cient, your home needs to breathe. Fresh air must
enter your home.All fuel-burning appliances need
fresh air for proper combustion and ventilation.
Internal wall installation provides a discreet
viewing option between two adjacent rooms or
within an added wall to subdivide an oversize
room.
Exhaust fans, fireboxes, clothes dryers and fuel
burning appliances draw air from the house to
operate. You must provide adequate fresh air for
these appliances. This will insure proper venting
of vented fuel-burning appliances.
pROVIDING ADEQUATE
VENTILATION
The following are excerpts from National Fuel
Gas Code ANS Z223.1/NFPA 54, Section 5.3, Air
for Combustion and Ventilation.
All spaces in homes fall into one of the three fol-
lowing ventilation classifications:
1. Unusually Tight Construction
2. Unconfined Space
Figure 2 - Projected Installation
3. Confined Space
The information on pages 5 through 7 will help
you classify your space and provide adequate
ventilation.
Unusually Tight Construction
The air that leaks around doors and windows
may provide enough fresh air for combustion and
ventilation. However, in buildings of unusually
tight construction, you must provide additional
fresh air.
105116-01D
5
Download from Www.Somanuals.com. All Manuals Search And Download.
DETERMINING FRESH-AIR FLOW
FOR FIREBOx LOCATION
aiR FOR COMBUSTiON
aND VENTiLaTiON
Determining if You Have a Confined or
Unconfined Space
Use this work sheet to determine if you have a
Continued
Unusually tight construction is defined as con-
struction where:
confined or unconfined space.
a. walls and ceilings exposed to the outside
atmosphere have a continuous water vapor
retarder with a rating of one perm (6 x 10-
Space: Includes the room in which you will install
heater plus any adjoining rooms with doorless
passageways or ventilation grills between the
rooms.
11
kg per pa-sec-m2) or less with openings
gasketed or sealed and
1. Determine the volume of the space (length x
width x height).
b. weather stripping has been added on open-
able windows and doors and
Length x Width x Height =__________cu. ft.
(volume of space)
c. caulking or sealants are applied to areas
such as joints around window and door
frames, between sole plates and floors,
between wall-ceiling joints, between wall
panels, at penetrations for plumbing, elec-
trical and gas lines and at other openings.
Example: Space size 22 ft. (length) x 18 ft.
(width) x 8 ft. (ceiling height) = 3168 cu. ft.
(volume of space)
If additional ventilation to adjoining room is
supplied with grills or openings, add the volume
of these rooms to the total volume of the space.
If your home meets all of the three criteria
above, you must provide additional fresh air.
See Ventilation Air From Outdoors, page 7.
2. Multiply the space volume by 20 to determine
the maximum Btu/Hr the space can support.
__________ (volume of space) x 20 = (Maxi-
mum Btu/Hr the space can support)
If your home does not meet all of the three cri-
teria above, proceed to Determining Fresh-Air
Flow for Firebox Location.
Example: 3168 cu. ft. (volume of space) x 20 =
63,360 (maximum Btu/Hr the space can support)
Confined and Unconfined Space
3. Add the Btu/Hr of all fuel burning appliances in
the space.
The National Fuel Gas Code ANS Z223.1/NFPA
54 defines a confined space as a space whose
volume is less than 50 cubic feet per 1,000 Btu
per hour (4.8 m3 per kw) of the aggregate input
rating of all appliances installed in that space and
an unconfined space as a space whose volume is
not less than 50 cubic feet per 1,000 Btu per hour
(4.8 m3 per kw) of the aggregate input rating of
all appliances installed in that space. Rooms com-
municating directly with the space in which the
appliances are installed*, through openings not
furnished with doors, are considered a part of the
unconfined space.
Gas water heater*
Gas furnace
_____________Btu/Hr
_____________Btu/Hr
_____________Btu/Hr
_____________Btu/Hr
Vented gas heater
Gas fireplace logs
Other gas appliances* +____________Btu/Hr
Total =____________Btu/Hr
* Do not include direct-vent gas appliances. Di-
rect-vent draws combustion air from the outdoors
and vents to the outdoors.
Example:
40,000
_____________Btu/Hr
39,000
+____________Btu/Hr
79,000
=____________Btu/Hr
Gas water heater
Gas firebox logs
Total
This heater shall not be installed in a confined
space or unusually tight construction unless provi-
sions are provided for adequate combustion and
ventilation air.
4. Compare the maximum Btu/Hr the space can
support with the actual amount of Btu/Hr used.
* Adjoining rooms are communicating only if
there are doorless passageways or ventilation grills
between them.
_________Btu/Hr (maximum the space can support)
_________Btu/Hr (actual amount of Btu/Hr used)
Example: 63,360 Btu/Hr (maximum the space
can support)
79,000 Btu/Hr (actual amount of
Btu/Hr used)
6
105116-01D
Download from Www.Somanuals.com. All Manuals Search And Download.
aiR FOR COMBUSTiON
WARNING: Rework work-
sheet, adding the space of the
adjoiningunconfinedspace.The
combined spaces must have
enough fresh air to supply all
appliances in both spaces.
aND VENTiLaTiON
Continued
The space in the above example is a confined
space because the actual Btu/Hr used is more than
the maximum Btu/Hr the space can support. You
must provide additional fresh air. Your options
are as follows:
A. Rework work sheet, adding the space of an
adjoining room. If the extra space provides an
unconfined space, remove door to adjoining
room or add ventilation grills between rooms.
See Ventilation Air from Inside Building.
Ventilation
Grills
Into Adjoining
Or
Room,
Remove
Option 1
Door into
B. Vent room directly to the outdoors. See Ven-
tilation Air from Outdoors.
Adjoining
Room,
Option
2
C. Install a lower Btu/Hr gas log heater, if lower
Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maxi-
mum Btu/Hr the space can support, the space is
an unconfined space. You will need no additional
fresh air ventilation.
Figure 3 - Ventilation Air from Inside
Building
WARNING: If the area in
which the firebox and gas log
heater may be operated is
smaller than that defined as
an unconfined space or if the
building is of unusually tight
construction, provide adequate
combustion and ventilation air
byoneofthemethodsdescribed
in the National Fuel Gas Code,
ANSZ223.1/NFPA54,Section5.3
or applicable local codes.
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or
ducts. You must provide two permanent openings:
one within 12" of the ceiling and one within 12"
of the floor. Connect these items directly to the
outdoors or spaces open to the outdoors. These
spaces include attics and crawl spaces. Follow the
National Fuel Gas Code ANS Z223.1/NFPA 54,
Section 5.3, Air for Combustion and Ventilation for
required size of ventilation grills or ducts.
IMPORTANT: Do not provide openings for inlet
or outlet air into attic if attic has a thermostat-
controlled power vent. Heated air entering the attic
will activate the power vent.
VENTILATION AIR
Ventilated
Outlet
Attic
Air
Ventilation Air From Inside Building
This fresh air would come from an adjoining un-
confined space. When ventilating to an adjoining
unconfined space, you must provide two perma-
nent openings: one within 12" of the ceiling and
one within 12" of the floor on the wall connecting
the two spaces (see option 1, Figure 3). You can
also remove door into adjoining room (see op-
tion 2, Figure 3). Follow the National Fuel Gas
Code ANS Z223.1/NFPA 54, Section 5.3, Air for
Combustion and Ventilation for required size of
ventilation grills or ducts.
Outlet
Air
To Attic
To
Crawl
Space
Inlet
Air
Ventilated
Inlet Air
Crawl Space
Figure 4 - Ventilation Air from Outdoors
105116-01D
ꢁ
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT: Vent-free gas log heaters add
moisture to the air. Although this is beneficial,
installing firebox in rooms without enough
ventilation air may cause mildew to form from
too much moisture. See Air for Combustion and
Ventilation, page 5.
iNSTaLLaTiON
NOTICE: This firebox in com-
bination with unvented log
sets are intended for use as
supplemental heat. Use along
with your primary heating
system. Do not install them as
your primary heat source. If you
have a central heating system,
you may run system’s circulat-
ing blower while using heater.
This will help circulate the heat
throughout the house. In the
event of a power outage, you
can use unvented logs as your
primary heat source.
IMPORTANT: Make sure the firebox is level. If
firebox is not level, log set will not work properly.
Note: Your Vanguard firebox is designed to be
used in zero clearance installations. Wall or fram-
ing material can be placed against any exterior
surface on the rear, sides or top of your firebox,
except where standoff spacers are integrally at-
tached. If standoff spacers are attached to your
firebox, these spacers can be placed directly
against wall or framing materials.
Use dimensions shown for rough openings to
create the easiest installation (see Built-In Firebox
Installation, page 9).
INSTALLATION CLEARANCES
WARNING: A qualified ser-
vice person must installfirebox.
Follow all local codes.
WARNING: Maintain the
minimum clearances. If you can,
provide greater clearances from
floor, ceiling and adjoining wall.
WARNING: Never install the
firebox
Carefully follow the instructions below. This will
ensure safe installation.
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture,
clothing or other flammable
objects are less than 42" from
the front, top or sides of the
firebox
Minimum Wall and Ceiling Clearances
A. Clearances from the side of the firebox open-
ing to any combustible wall should not be less
than 8 ".
B. Clearances from the top of the firebox opening
to the ceiling should not be less than 42".
• in high traffic areas
• in windy or drafty areas
C. When the firebox is installed on carpeting or
other combustible material, other than wood
flooring, the firebox should be installed on a
metal or wood panel extending the full width
and depth of the enclosure.
CAUTION: Log heaters
installed in this firebox create
warm air currents. These cur-
rentsmoveheattowallsurfaces
next to firebox. Installing fire-
box next to vinyl or cloth wall
coverings or operating firebox
where impurities (such as, but
not limited to, tobacco smoke,
aromatic candles, cleaning flu-
ids, oil or kerosene lamps, etc.)
in the air exist, may discolor
walls or cause odors.
D. Clearances from the bottom of firebox to the
floor is 0".
CAUTION: Do not install
the firebox directly on carpet
or vinyl.
CAUTION:Useonlytheclear-
ancesspecifiedinthismanualor
on the firebox rating plate.
8
105116-01D
Download from Www.Somanuals.com. All Manuals Search And Download.
iNSTaLLaTiON
CAUTION: Do not allow the
vent-freegaslogheatertotouch
or extend beyond the firebox
screen.
Continued
Minimum clearances to combustibles are:
•
•
Sides of outer casing
0" min.
0" min.
Drywall to sides and top of
front face
If your installation does not meet the above mini-
mum clearances in Figure 7, you must:
•
•
Ceiling to opening
42' min.
0" min.
•
raise the mantel to an acceptable height,
Floor (see Minimum Wall
and Ceiling Clearances, note C)
OR
•
•
Perpendicular walls
Right and Left
4' min.
remove the mantel.
Wall board or facing material
(above firebox) may be of
combustible material, including
decorative mantel ornaments
or other similar projections
off of the facing material.
•
Distance to Facing Walls
36" min.
See Figures 5 and 6.
0" Min. Clearance to
Upper Frame/Wallboard
Mantel Shelf
Top Frame
(Combustible Material)
Ceiling
8" Min.
42" Min.
9 1/4"
6"
3"
Combustible
Material 1 1/2"
Max Thickness
Firebox Top
15" 18"
12"
Note: Do not
7" Min. cover louver
openings.
0" to Wood Floor
Note: All vertical
measurements are
from top of fireplace
hood to bottom of
mantel shelf. These
minimum clearances
replace any other
recommended
Wire-mesh
Screen
Figure 5 - Minimum Clearance -
Front View
Supplied
Firebox Hoods
Must Be Used
at All Times
clearances supplied
with your ANS Z21.11.2
approved gas logs.
1/2" Min. Clearance
to Combustibles
Figure 7 - Minimum Mantel Clearances
for Built-In Installation
24"
BUILT-IN FIREBOx INSTALLATION
Built-ininstallationofthisfireboxinvolvesinstalling
firebox into a framed-in enclosure. This makes the
front of firebox flush with wall. Optional perimeter
brasstrimaccessoriesareavailable(seeAccessories,
page 18). The brass trim will extend past sides of
fireboxapproximately1/2".Thiswillcovertherough
edgesofthewallopening.Ifinstallingamantelabove
the firebox, you must follow the clearances shown
in Figure 7. Follow the instructions below to install
the firebox in this manner.
44 1/4"
4" Min. from the Perpendicular
Side Wall to the Edge of Facial
Figure 6 - Minimum Clearance - Top View
Mantel Clearances for Built-In
Installation
If placing custom mantel above built-in firebox,
you must meet the minimum allowable clearance
between mantel shelf and top of firebox opening
showninFigure7.Thesearetheminimumallowable
mantel clearances for a safe installation. Use larger
clearanceswhereverpossibletominimizetheheating
of objects and materials placed on the mantel.
1. Frame in rough opening. The firebox framing
should be constructed of 2 x 4 lumber or heavier.
Construct framing using dimensions shown in
Figure 8 and 9, page 10. It is recommended that
the framing be constructed first and the unit
be placed in position by removing the nailing
flanges from one side.After sliding the unit into
place, the outer most flanges may be replaced
and nailed to the framing on all sides before
applying the wallboard to the exterior framing.
105116-01D
ꢂ
Download from Www.Somanuals.com. All Manuals Search And Download.
7. Attach firebox to wall studs using nails or
wood screws through holes in nailing flange
(see Figure 10).
iNSTaLLaTiON
Continued
2. If the vent-free firebox is to be installed directly
on carpeting, tile (other than ceramic) or any
combustible material other than wood flooring;
the vent-free firebox must be installed upon a
metal or wood panel extending the full width
and depth of the vent-free firebox.
8. If using optional brass trim kit, install the trim
after final finishing and/or painting of wall.
See instructions included with brass trim ac-
cessory for attaching brass trim.
IMPORTANT: When finishing your firebox,
combustible materials such as wall board, gypsum
board, sheet rock, drywall, plywood, etc. may be
butted up next to the sides and top of the firebox.
Combustible materials should never overlap the
firebox front facing.
3. If a raised platform is to be constructed, ceiling
clearances must be maintained.
4. Install gas piping to firebox location. See In-
stalling Gas Line on page 11 and Connecting
to Gas Supply in log set owner’s manual.
IMPORTANT: If installing blower accessory. See
Hard-Wiring Firebox, page 12.
WARNING: Do not allow any
combustible materials to over-
lap the firebox front facing (see
Figure 9).
5. Carefully set firebox in front of rough open-
ing. IMPORTANT: If installing brass trim
kit, see instructions included with brass trim
accessory. You must install shoulder screws
from brass trim kit now.
IMPORTANT: Noncombustible materials such as
brick, tile, etc. may overlap the front facing, but
should never cover any necessary openings like
louvered slots.
6. Carefully insert firebox into rough opening.
22 3/4"
Min.
WARNING: Never modify or
cover the louvered slots on the
front of the firebox.
Wallboard
Note: Gas line
may also be on
Gas Line
opposite side.
WARNING:Useonlynoncom-
bustiblemortaroradhesiveswhen
overlapping the front facing with
noncombustible facing material.
Facing
Wall
44 1/4" Min.
Wallboard
Facing Wall
(Base line)
40 1/4" Min.
36" Min. to
Facing Wall
Nails or
Wood
Screws
Figure 8 - Framing for Built-In Firebox
Installation
Combustible material must
not overlap more than
3/8" onto black metal
front face.
Edge
Nailing Flange
Drywall
of side
firebox
opening
3/8" Max.
SAFE
ZONE
11/2" Max.
Minimum from firebox
edge to combustible
material
4"
8" Min. from
adjacent wall
to fireplace
opening
Nailing Flanges
Figure 9 - Framing for Built-In Firebox
Installation: Top View
Figure 10 - Attaching Firebox to Wall Studs
10
105116-01D
Download from Www.Somanuals.com. All Manuals Search And Download.
A manual shutoff valve, CSA certified and com-
plying with the National Fuel Gas code, ANS
Z223.1/NFPA 54, must be included within (6') six
feet of the vent-free firebox gas supply system. It
may be convenient to install the gas shutoff outside
the vent-free firebox enclosure where it can be
accessed with a key through a wall as shown in
Figure 13. Depending on the type of installation,
some local codes may require you to install two
(2) manual shutoff valves independently accessible
from both rooms. Check your local codes for ap-
plicable installation requirements.
iNSTaLLaTiON
Continued
INSTALLING GAS LINE
WARNING: A qualified ser-
vicepersonmustconnectheater
to gas supply. Follow all local
codes.
IMPORTANT: See Connecting to Gas Supply in
your log set owner’s manual for details on gas
hookup.
A 36" long 1/2" NPT SCHD 40 flexible gas con-
nector line complying with the National Fuel Gas
code ANS Z223.1/NFPA 54, may be run from the
regulator to the incoming 1/2" NPT black iron
gas line. You may also route the incoming 1/2"
NPT black iron gas line directly to the appliance
regulator.
You may run the gas line from either side of the
firebox (see Figure 11). When you have deter-
mined how the gas line will run, locate one of
the recessed knockouts in the firebrick floor (see
Figure 12). Firmly tap the center of the knockout
with a chisel until it is released. Carefully chisel
the rough edges of the hole you have made to
smooth edges. This hole will line up with the hole
in the metal floor.
The incoming gas line may be routed into the vent-
free firebox either from the left or right hand sides
(see Figure 11). Remove the gas line cover plate
from the vent-free firebox’s outer surround at the
location to be used.
CAUTION:Donotuseexces-
sive force to remove the knock-
out.Toomuchforcemaydamage
the firebrick concrete insert.
Firebrick Floor
Gas Line Installed
Through Access Hole
on One Side of Firebox
Knockouts
Remove This Area
3/4" Thick Liner
Figure 12 - Location of Knockouts for
Gas Line
Shut-Off Valve
Extension
Key
Manual Shutoff Valve is
Located Under Firebox
Floor on Either Side
Alternative
Gas Line
Location
Figure 11 - Installing Gas Line and
Manual Shutoff Valve
Figure 13 - Typical Exterior Wall Gas
Shut-Off Installation
105116-01D
11
Download from Www.Somanuals.com. All Manuals Search And Download.
GAS SUppLY TESTING
iNSTaLLaTiON
Note: This section is intended as a guide for
qualified technicians installing gas to this vent-
free firebox.
Continued
If a sediment trap is not incorporated as a part of
the gas utilization equipment, one shall be installed
as close to the inlet of the equipment as practical at
the time of installation, as per ANS Z223.1/NFPA
54. See Figure 14.
CAUTION: Do not connect
vent-freeheaterbeforepressure
testing gas piping. Damage to
gas valve may result and an un-
safe condition may be caused.
Prepare incoming black iron gas line with Teflon
tape or pipe joint compound (check with local
codes as to the use of Teflon tape). Compounds
used on threaded joints of gas piping shall be
resistant to the action of propane/LP and should
be applied lightly to ensure excess sealant does
not enter the gas line.
The appliance and its’ individual shutoff valve
must be disconnected from the gas supply piping
system during any pressure testing of that system at
test pressures in excess of 1/2 psig (3.5 kPa).
Complete your gas installation by connecting
the incoming gas line to the appliance regulator.
Secure all joints tightly with wrench but do not
overtighten. If a flexible gas line is used, take care
not to kink the connector.
The appliance must be isolated from the gas
supply piping system by closing manual shutoff
valve during any pressure testing of the gas sup-
ply piping system at test pressures equal to or
less than 1/2 psig (3.5 kPa).
WARNING: All gas piping
and connections must be tested
for leaks after the installation is
completed. After ensuring that
the manual shutoff gas valve is
open, apply a soap and water
solution to all connections and
joints. If bubbles appear, leaks
can be detected and corrected.
DONOTUSEOpENFLAMEFOR
LEAK TESTING AND DO NOT
OpERATE ANY AppLIANCE IF
A LEAK IS DETECTED.
HARD-WIRING FIREBOx
Model FBST can be hard-wired to the duplex
outlet located inside the firebox bottom if desired.
This allows the blower accessory to be plugged
into the duplex outlet.
NOTICE: A qualified electrician
mustconnectelectricalwiringto
duplex outlet for built-in instal-
lation. Follow all local codes.
In absence of local codes fol-
low The National Electric Code
ANS/NFPA 70.
ELECTRICAL INSTALLATION
A model GA3500A blower system assembly is
available for use with the FBST vent-free firebox
as an optional accessory. This blower is designed
to be installed on either side of the FBST firebox,
when provisions for a 120 VAC supply connection
are made at either end of the cabinet. Use of a
blower system other than those manufactured by
DESA voids the warranty.
Incoming 1/ꢀ"
Gas Line
Permitted by
Local Codes
Sediment Trap
(Not Supplied)
Electrical connections are made within the recep-
tacle with wires that are routed through the bushing
provided (see Figure 15, page 13). The receptacle
may be relocated to either side, when necessary.
However, the cover plate must be replaced over the
unused access point. Be certain to properly ground
the vent-free firebox using the green grounding
wire (see Figure 17 on page 14).
Figure 14 - Sediment Trap Installation
1ꢀ
105116-01D
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Install blower housing with exhaust outlet
ports directed upwards along inner side wall of
lower compartment. The blower outlets must
be installed flush to the outer cabinet for air
to flow properly.
iNSTaLLaTiON
Continued
Note: A 120V supply connection to the leads to
the receptacle must be provided for use with the
optional blower kit whether installed during or
after initial firebox installation. You may not be
able to install a supply connection after the final
installation is completed. Refer to Optional Blower
Assembly Installation for specifics.
5. Apply gentle force between hook and loop
mounting strips to seat blower.
6. Remove control knob and lock nut from
blower speed control shaft.
7. Place speed control shaft through 3/8" hole
provided in right side of lower door panel
removed in step 2.
Gas Connection
Access Hole
8. While supporting speed control housing, se-
cure shaft in panel hole with lock nut. Place
control knob on shaft.
9. Plug blower power cord into receptacle lo-
cated in lower firebox compartment. Check
to make sure there are no foreign objects in
blower wheel.
Electrical
Connection
Access Hole
Cover
Plates
WARNING: Never touch the
blower wheel while in operation.
10. Turn blower on and check for proper operation.
11. Turn blower off before continuing.
Figure 15 - Locating Electrical
Connection and Gas Connection on
Either Side of Fireplace
12. Replace lower door panel by inserting tabs on
bottom of panel into locating slots on firebox.
Push door panel into an upright position and
secure with screws removed in step 2.
OpTIONAL BLOWER ASSEMBLY
INSTALLATION
Proper installation of the blower system is required
to insure that the maximum discharge of air can
be delivered through the louvers on each side of
the fireplace.
Locating
Slot
Locating
Holes
Note: You may perform this installation from
either side of the fireplace within either room. The
lower door panels are removable from both sides
of the firebox for better access.
1. Remove the blower assembly from the pack-
aging and inspect the fan and wiring for dam-
age. If any wiring is loose or damaged, return
the assembly for exchange to your dealer or
distributor.
Door Panel
2. Remove the 2 screws located at the top of the
lower door panel. Slide door panel forward
and up to remove tabs on panel from locating
slots in firebox (see Figure 16).
Locating Slot
Figure 16 - Removing Lower Door Panel
3. Locatethetwostripsofhookandloopmounting
strips on one side of the base of the lower com-
partment. Align the mounting strips on blower
with mounting strips on base of firebox.
105116-01D
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Receptacle
iNSTaLLaTiON
Continued
Blower
Speed
Control
Shaft
Hook and Loop
Mounting Strips
Lock
Nut
Control
Knob
Figure 18 - Installing Optional Blower
GA3500A
HEAT DEFLECTIVE HOOD
INSTALLATION
The factory supplied heat deflective hoods must
be installed inside the fireplace opening on both
sides for the safe operation of the unit as shown
in Figure 19.
1. Remove protective covering from hoods.
2. Position deflective hood into opening on one
side of the firebox and secure to the top of the
opening using screws provided.
3. Secure the ends of the hood to the firebox
using two screws (provided) for each side.
4. Repeat steps 2 and 3 to install hood on the
opposite side of the firebox.
CAUTION:Donotcleanhood
withabrasivecleanser.Useonly
regularhouseholdcleanersand
a smooth cloth.
Figure 17 - Optional Blower Wiring
Diagram
Operating Optional Blower GA3500A
Light your gas appliance with the blower off.After
about 10 minutes, turn the blower on to deliver
heated air out the top louvers. The blower features
a variable control which allows you to select the
blower speed you desire.
Front Hood
(Typical Each Side)
Corner
Post
Note: Periodically check the louvers of the firebox
and remove any dust, dirt or obstructions.
3 Screws
(Top)
2 Screws Each
End of Hood
Figure 19 - Typical Hood Installation
(Both Sides)
14
105116-01D
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERaTiNg gUiDELiNES
aND MaiNTENaNCE
iNSTRUCTiONS
REPLaCEMENT PaRTS
Note: Use only original replacement parts. This
will protect your warranty coverage for parts
replaced under warranty.
When lit for the first time, a vent-free log heater will
emit a slight odor for about an hour or two. This is
a normal occurrence which is due to the “curing”
of the logs and the “burn-in” of internal paints and
lubricants used in the manufacturing process.
pARTS UNDER WARRANTY
Contact authorized dealers of this product. If they
can’t supply original replacement part(s), call
DESA at 1-866-672-6040.
Keep control compartments, logs, burners and
areas surrounding the logs clean by vacuuming or
brushing at least twice a year. Temporary removal
of the log set may ease the cleaning of the burner
and pilot assembly. In cleaning, take care not to
alter the settings on the pilot assembly. See the
operating instructions supplied with your vent-free
log heater for additional cleaning instructions.
When calling DESA, have ready
•
•
•
•
•
•
your name
your address
model and serial numbers of your firebox
how firebox was malfunctioning
type of gas used (propane/LP or natural gas)
purchase date
Usually, we will ask you to return the defective
part to the factory.
WARNING:Logscanbevery
hot! Allow logs to cool before
handling.
pARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If
they can’t supply original replacement part(s),
call DESA at 1-866-672-6040 for referral infor-
mation.
IMPORTANT: Turn off the gas supply at the exter-
nal shutoff valve before servicing appliance. Any
safety screen or guard removed for servicing must
be replaced prior to operating the appliance.
When calling DESA, have ready
•
model number of your firebox
Installation and repair should be done by a quali-
fied person. The appliance should be inspected
before use and at least annually by a professional
service person. More frequent cleaning may be
required due to excessive lint from carpeting, pet
hair, etc. It is imperative that the control compart-
ments, burners and circulating air passageways of
the appliance be kept clean.
•
the replacement part number
Note: The firebox identification label (including
model number, serial number, clearances, etc.) is
located above the brick liner and under the heat
shield. See Figure 20.
Air Deflector
Heat Shield
Identification Label
WARNING: Children and
adults should be alerted to the
hazardsofhighsurfacetempera-
tures and to stay away to avoid
burnsorclothingignition.Young
children should be carefully
supervised when they are in the
same room as the appliance.
For lighting and operating this vent-free firebox,
please refer to the vent-free gas logs manufactur-
er’s instruction manual.
Brick Liner
Figure 20 - Location of Firebox
Identification Label
105116-01D
15
Download from Www.Somanuals.com. All Manuals Search And Download.
iLLUSTRaTED PaRTS BREakDOWN
MODEL FBST
15
4
15
10**
15
15
3
16**
15
15
15
14
15
14
15
16**
15
15
15
4
6
1
6
15
15
6
16**
15
14
6
16**
15
11**
16**
13
13
15
7-1
6
12
**
16**
7-2
7-1
2
16**
16**
16**
15
8**
9**
**These items are used on both sides of fireplace.
16
105116-01D
Download from Www.Somanuals.com. All Manuals Search And Download.
PaRTS LiST
MODEL FBST
This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions
listed under Replacement Parts on page 15 of this manual.
KEY
NO.
pART NO.
***
DESCRIpTION
QTY.
1
1
1
ꢀ
Firebox Assembly
Firebox Bottom
***
3
***
Firebox Top
1
4
5
6
ꢀ3ꢂ8ꢀ
ꢀ6ꢁ31
ꢀ6ꢁ40
Top Spacer
Deflector Hood
Nailing Flange
4
ꢀ
8
ꢁ-1 0ꢀ013
ꢁ-ꢀ 0ꢀ014
ꢀ400ꢁ
Side Refractory Brick Liner
Bottom Refractory Brick Liner
Side Refractory Retainer
Screen
ꢀ
ꢀ
4
4
8
ꢂ
1ꢀ1ꢀ5
10
11
1ꢀ
13
14
15
16
ꢀ6ꢁ5ꢀ
ꢀ6ꢁ33
14ꢀ00
ꢀ11ꢁ1
Extruded Louver
Lower Door Panel
Receptacle
ꢀ
ꢀ
1
6
14
ꢀ4
46
Access Hole Cover
0ꢂꢂꢀ30-01 Shoulder Screws
11164
11165
Screw, #10 x 1/2, zinc PH
Screw, #10 x 5/8, zinc PH
pARTS AVAILABLE - NOT SHOWN
Installation Instructions
554ꢁ3
ꢀ6544
1
1
Rating Plate Label
***Not a field replaceable part.
105116-01D
1ꢁ
Download from Www.Somanuals.com. All Manuals Search And Download.
TEChNiCaL SERViCE
You may have further questions about installation,
operation or troubleshooting. If so, contact DESA
at 1-866-672-6040.
You can also visit DESA Technical Service web
POLISHED BRASS HOOD - GA6054
Replaces the standard black hood to provide a
more formal appearance. Note: Kit is for one side
of firebox only. Two kits are required to do both
sides of fireplace.
aCCESSORiES
Purchase these firebox accessories from your local
dealer. If they can not supply these accessories, call
DESAat 1-866-672-6040 for information.You can
also write to the address listed on the back page
of this manual.
POLISHED BRASS LOUVER - GBL41
Replaces the standard black louver to provide a
more formal appearance. Note: Kit is for one side
of firebox only. Two kits are required to do both
sides of fireplace.
BLOWER - GA3500A
An optional blower is available for use with the
FBST fireboxes for bidirectional heat circula-
tion and may be installed during or after firebox
installation.
BRASS TRIM - GA6093
Easily clips around firebox to provide a finished
appearance covering rough and or unfinished
mantel edges. Note: Kit is for one side of firebox
only. Two kits are required to do both sides of
fireplace.
18
105116-01D
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES
_____________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
_____________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
_____________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
105116-01D
1ꢂ
Download from Www.Somanuals.com. All Manuals Search And Download.
WaRRaNTy iNFORMaTiON
kEEP ThiS WaRRaNTy
Model
Serial No.
Date Purchased
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our
standard written warranty. We make no other warranty, expressed or implied.
LiMiTED WaRRaNTy
VENT-FREE FiREBOX
DESA warrants this product to be free from defects in materials and components for four (4) years from the date
of first purchase, provided that the product has been properly installed, operated and maintained in accordance
with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must
be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to
restore this heater to proper operating condition and an allowance for labor when provided by a DESAAuthorized
Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA who
will provide original factory replacement parts. Failure to use original factory replacement parts voids this war-
ranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions
furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts
that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by
improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to
repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE
OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED
WARRANTIESAND LIMITS THE DURATION OFANYAND ALL IMPLIED WARRANTIES, INCLUDING
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO FOUR (4)
YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA’S LIABILITY IS
HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA HEATING PRODUCTS
SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCI-
DENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of
incidental or consequential damages, so the above limitation on implied warranties or exclusion or limitation on
damages may not apply to you.