KEY FEATURES
BATTERY INSTALLATION
1. Replace the battery when the “low battery”
warning symbol appears.
• Your child’s temperature is taken every
5 seconds
• The thermometer transmits your child’s
temperature to your portable Parents’ Unit
every 10 seconds
2. Use a coin to rotate the battery cover (on the
back) counter-clockwise to open.
3. Insert a new 3-volt CR2032 lithium battery
with the anode (+) side facing up and close
the battery cover.
• Alerts you if your child’s fever is rising
• Alarm can be set for 5 different temperature
readings: 98°F, 99°F, 100°F, 101°F, and
102°F/36.7°C, 37.2°C, 37.8°C, 38.3°C, and
38.9°C
• Alarm will sound if the Child’s Thermometer
loses contact with the skin or has been
accidentally turned off
• Child’s Thermometer is water resistant
• Small and lightweight design makes it
comfortable for both child and parent to wear
• Powers off automatically to ensure a long
battery life if the temperature has measured
below 91.4°F/33°C for more than 20 minutes
• Special belt included to insure thermometer is
secured against the child’s stomach
• Easy to read LCD display
• Temperature shown in Fahrenheit (F) or
Celsius (C)
4
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Parents’ Unit
INSTRUCTIONS FOR USE
1. Turn on the baby’s thermometer by pressing
the power button for approximately 2 sec-
onds. The LCD display will show the
temperature data.
Buzzer: An alarm for
abnormal temperatures
Warning Light: Alarm
2. Clip the thermometer to the
baby’s diaper, pajamas, or
our special belt, approxi-
mately one inch (2-3 cen-
timeters) to the left of the
belly button. If you are using
the belt provided, it’s best to
fasten it over the diaper or
pajamas to avoid any
LCD Screen
Set Button:
A. Push 2 seconds to
switch between
°C & °F.
B. Choose high
temperature (fever
warning
temperature point
Warning Cancel Button:
Temporarily cancels buzzer sound
possible irritation. Make
sure the temperature sensor
on the back of the unit is in
contact with the skin and that
your baby is wearing clothing
covering the stomach to avoid the loss of
body heat.
Power Button:
A. Push 2 seconds to turn power on or off
B. Push to set the fever alarm temperature
Child’s Thermometer
3. Turn on the Parents’ Unit by pressing the
power button for approximately 2 seconds.
The LCD display will show it is searching for
the signal from the thermometer. After
several seconds the LCD display will show
the temperature reading received from the
thermometer.
LCD Screen
Set Button:
Push 2 seconds to
switch between
°C & °F
4. To switch between Celsius and Fahrenheit, press
the (S) button for approximately 2 seconds. Both
units have to be independently set.
Power Button:
Push 2 seconds to turn
power on or off
6
7
Download from Www.Somanuals.com. All Manuals Search And Download.
5. To set the alarm push the power button and
the LCD display will flash an alarm setting
and read “SET.” The temperature alarm has
five settings: 98°, 99°, 100°, 101°, and
102°F/36.7°C, 37.2°C, 37.8°C, 38.3°C, and
38.9°C. To change the alarm setting press
the (S) button once for each setting until you
reach the desired temperature.
UNDERSTANDING THE SYMBOLS
• Information is being received
• Temperature is under the alarm
set point
• Temperature reading is at or
above the set point
Remember, temperature readings taken abdominally may be
.7°~1.4°F (.4°C~.8°C) lower than rectal readings. This differ-
ential should be considered when monitoring your child’s tem-
perature and when you set the alarm. For example, you may
want to set the alarm for 100 if you want to know if your
child’s fever reaches 101. (See Note on P. 3)
• Signifies low battery
• Temperature above or below the
Monitor’s range
LO/HI
6. After you have set the alarm push the power
button again and the LCD screen will return
to the monitor mode showing your child’s
temperature.
APPROVALS AND APPLIED
STANDARDS
7. The first time the Fever Monitor is used wait
approximately 20 minutes for the thermo-
meter to reach a fully accurate temperature
read. After the first time, no waiting period is
required.
FDA approved. For home use only.
The following standards apply to design and/or
manufacturing of the product:
• ASTM Standard E 1112
• EN 60601-2
• EN 60601-1
• ETSI300-683
8. If the alarm sounds, temporarily turn it off by
depressing the “Cancel” button on the
Parents’ Unit.
• ETSI 300-220
FCC Approved: OV4RT910
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference,
and (2) This device must accept any interference
received, including interference that may cause
undesired operation.
9. To achieve maximum transmission range,
avoid placing the Parents’ Unit on or close to
metal articles or electrical appliances.
Use of the Remote Fever Monitor should not replace a visit to
your doctor. It is recommended that you advise your doctor
any time a temperature is above 100°F/37.8°C.
8
9
Download from Www.Somanuals.com. All Manuals Search And Download.
CARE AND CLEANING
TROUBLESHOOTING
1. The Remote Fever Monitor is a delicate
electronic device. To insure proper functioning,
do not immerse either unit in water and avoid
dropping them.
Poor Reception
Cause: Child’s Thermometer is not sending a
signal or the distance between both units is
beyond the specified range for over 40 seconds.
Effect: Parents’ Unit will beep 3 times at 10
second intervals and the receiving symbol will
disappear and SCAN will appear.
2. Clean both units with a soft cloth moistened
with either water or alcohol. Never use an
abrasive.
Solution: Check the position of the thermometer
and/or move back into the transmission range.
3. Keep out of the reach of children and in the
storage case when not in use. The optimal
storage temperature is between -4°~140°F/-
20°~60°C.
Low Battery
Cause: Battery power is too low to operate the
unit.
Effect: Parents’ Unit will beep every 5 minutes
4. Do not disassemble the thermometer.
and the low battery symbol will appear.
If you believe your Remote Fever Monitor is
not operating properly, please check the
batteries first. If it still does not operate
normally, or you are having other technical
problems, please contact:
Solution: Change the battery in whichever unit
is causing the problem or in both units.
Temperature Too Low
Cause: Thermometer lost contact with baby’s
skin or the baby’s temperature is too low.
Unisar Inc.
Effect: The Parents’ Unit will beep for 10 sec-
onds.
15 West 36th Street
New York, NY 10018
Tel. 1-888-232-6476
Solution: Check your child and the position of
the thermometer immediately.
10
11
Download from Www.Somanuals.com. All Manuals Search And Download.
TECHNICAL DATA
LIMITED PRODUCT WARRANTY
BébéSounds® Remote Fever Monitor, distributed
by Unisar Inc., has a limited warranty against
malfunctions for a period of one year from the
original purchase date. Battery life or damage
due to misuse or abuse is excluded from this
warranty.
• For household use only
• Consult your doctor before using if there is a
Pacemaker implanted
• Temperature measurement range:
62.6°~109.4°F/17.5°~43°C
• Temperature display range:
62.6°~109.4°F/17.5°~43°C
In-Warranty Procedure
• Ambient operating environment:
60.8°~122°F/16.5°~ 50°C
In the event service is required due to malfunc-
tion during the warranty period, Unisar Inc. will
replace or repair the product under warranty.
The repair or replacement of the malfunctioning
item will be free of charge. Repair or replace-
ment of the malfunctioning item is subject to
verification of the malfunction when delivered
to:
• Ambient storage environment:
-4°~140°F/-20°~60°C)
• Temperature accuracy: +/- 0.3°F/0.2°C
between 95°~98.6°F/35.8° ~ 37°C; +/- 0.2°F/0.1°C
between 98.6°~102.2°F/37°~39°C; and
+/-0.3°F/0.2°C between 102.2°~105.8°F/39°~41°C
• Each unit requires one 3-volt CR-2032 lithium
battery (included)
Unisar® Service Center
15 West 36th Street
New York, NY 10018 USA
• Transmission frequency: 433.92MHz
• Transmission range: approximately 90 feet/30 meters
• Recommended for use with children under 8 years old
• Factory calibration lasts approximately five years
Please enclose dated proof of purchase with
your return.
• Battery life: approximately 12 months, 2 months if
used continuously
• For longest battery life remove batteries when
not in use
12
13
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES
NOTES
14
15
Download from Www.Somanuals.com. All Manuals Search And Download.
If you are having difficulty, have questions,
or need assistance, call our Help Desk
toll free at 1-888-232-6476
Mon-Fri from 9:00AM-5:00PM EST.
The Remote Fever Monitor is a
Personal Care Product and cannot be
returned to the retailer. All exchange
and refund requests should be directed
to the BébéSounds® Help Desk
toll free at 1-888-232-6476.
Unisar Inc.
15 West 36th Street
New York, NY 10018
Tel. 1-800-232-1196
visit us at
© 2002 Listro Associates