CONTENTS
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Important Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Terminology. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
What is Scanning? . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
What is Searching? . . . . . . . . . . . . . . . . . . . . . . . . . . 5
What is Trunk Tracking? . . . . . . . . . . . . . . . . . . . . . . 5
Feature Highlights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Where to Obtain More Information . . . . . . . . . . . . . . . . . 9
Information on the Internet . . . . . . . . . . . . . . . . . . . . . 9
Included with Your Scanner . . . . . . . . . . . . . . . . . . . . . 10
Setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Installing the Battery Pack . . . . . . . . . . . . . . . . . . . . 11
Charging the Battery Pack . . . . . . . . . . . . . . . . . . . . 12
Low Battery Indicator . . . . . . . . . . . . . . . . . . . . . . . . 12
Adapter Safety Feature . . . . . . . . . . . . . . . . . . . . . . 12
Flexible Antenna . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Belt Clip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Basic Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Turn the Scanner On . . . . . . . . . . . . . . . . . . . . . . . . 14
Setting the Squelch . . . . . . . . . . . . . . . . . . . . . . . . . 14
Keylock. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
LCD Back Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Auto Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Programming. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Duplicate Frequency Alert . . . . . . . . . . . . . . . . . . . . 18
Programming Tips . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Deleting a Stored Frequency . . . . . . . . . . . . . . . . . . 19
Scanning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
RF Attenuation Feature . . . . . . . . . . . . . . . . . . . . . . 21
Setting the Delay Mode . . . . . . . . . . . . . . . . . . . . . . 22
Channel Lockout . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Lockout Tips. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Restore a Locked Out Channel . . . . . . . . . . . . . . . . 25
Restore All Locked-Out Channels . . . . . . . . . . . . . . 25
Priority Scan. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Changing the Priority Channel . . . . . . . . . . . . . . . . . 27
Searching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Setting a Search Range . . . . . . . . . . . . . . . . . . . . . . 28
Turbo Search . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Search Hold Feature . . . . . . . . . . . . . . . . . . . . . . . . 29
Data Skip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Frequency Skip . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Storing Search Frequencies. . . . . . . . . . . . . . . . . . . 30
SVC Scanning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
SVC Scan Lockout . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Programming with SVC Scan. . . . . . . . . . . . . . . . . . 35
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
The BC 245XLT is a state-of-the-art radio with
TrunkTracking™ and automatic scanning capabilities. It
can store frequencies such as police, fire/emergency,
marine, railroad, air, amateur, and other communications
into 10 banks of 30 channels each.
With the new SmartScanner™ feature, you can also
automatically program your scanner by downloading
directly from our Uniden/Bearcat national frequency
database via a PC or external modem.
Use your new scanner to monitor:
UHF High Band UHF 800/900 MHz Trunked Public
Safety Systems
Police and Fire Departments (including rescue and
paramedics)
Trunking for Motorola and EDACS systems
NOAA Weather Broadcasts
Business/Industrial Radio
Utilities
Marine and amateur (ham radio) bands
Air band
Frequency Range
29.0-29.7 MHz
29.7-50.0 MHz
50.0-54.0 MHz
Steps
5 kHz
5 kHz
5 kHz
Transmission
10 Meter Amateur Band
VHF Low Band
6 Meter Amateur Band
108-137 MHz 12.5 kHz Aircraft Band
137-144 MHz
144-148 MHz
148-174 MHz
5 kHz
5 kHz
5 kHz
Military Land Mobile
2 Meter Amateur Band
VHF High Band
406-420 MHz 12.5 kHz Federal Govt.
420-450 MHz 12.5 kHz 70cm Amateur Band
450-470 MHz 12.5 kHz UHF Standard Band
470-512 MHz 12.5 kHz UHF “T” Band
806-956 MHz 12.5 kHz Public Service “800”
Band
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Important Notice
This scanning radio has been manufactured so
that it will not tune radio frequencies assigned by
the FCC for cellular telephone usage. The
Electronic Communications Privacy Act of 1986, as
amended, makes it a federal crime to intentionally
intercept cellular or cordless telephone
transmissions or to market this radio when altered
to receive them.
The installation, possession, or use of this
scanning radio in a motor vehicle may be
prohibited, regulated, or require a permit in certain
states, cities, and/or local jurisdictions. Your local
law enforcement officials should be able to provide
you with information regarding the laws in your
community.
Changes or modifications to this product not
expressly approved by Uniden, or operation of this
product in any way other than as detailed by this
Operating Guide, could void your authority to
operate this product.
The screen displays used in this manual are
representations of what might appear when you
use your scanner.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Terminology
What is Scanning?
Unlike standard AM or FM radio stations, most two-way
communications do not transmit continuously. The
BC 245XLT scans the channels you program until it finds
an active frequency.
Scanning stops on an active frequency and remains on
that channel as long as the transmission continues. When
the transmission ends, the scanning cycle resumes until
another transmission is received.
What is Searching?
The BC 245XLT can search each of its 12 bands to find
active frequencies. This is different from scanning because
you are searching for frequencies that have not been
programmed into your scanner. You can choose between
two speeds while searching. Turbo Search, a new feature
for Uniden scanners, can search the VHF FM bands at up to
300 channels per second.
What is Trunk Tracking?
Conventional scanning is a simple concept. You enter a
radio frequency in your scanner’s memory which is used by
someone you want to monitor. For example, the police in
your area may broadcast on 460.500 MHz , the fire
department on 154.445 MHz, the highway department on
37.900 MHz, etc. So when your scanner stops on a
frequency, you usually know who it is, and more
importantly, you can stop on a channel and listen to an
entire conversation. This type of scanning is easy and fun.
As the demand for public communications has increased,
many public radio users don’t have enough frequencies to
meet their needs, and this has created a serious problem.
Trunking radio systems solve this problem.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
In a trunked radio system, which contains up to 28 different
frequencies, radio users are divided into groups, often
called talk groups, and these talk groups are assigned
specific IDs. When someone in a talk group uses their
radio, a brief burst of data is broadcast before each
transmission. The trunking system computer uses this data
to temporarily assign each radio in a talk group to an
available frequency. If the group using a frequency stops
broadcasting or pauses between replies for a few seconds,
they are removed from the frequency so another talk group
can use it.
Sharing of the available public service frequencies, or
trunking, allows cities, counties, or other agencies to
accommodate hundreds of users with relatively few
frequencies. Following a conversation on a trunked system
using a scanner is difficult, if not impossible, because when
there’s a short break during the conversation you’re
monitoring, it’s possible that the talk group will be assigned
to a completely different frequency in the trunked system.
This type of scanning is difficult and frustrating.
TrunkTracker™ changes this! Not only does your new
BC 245XLT scan channels like a conventional scanner, it
actually follows the users of a trunked radio system. Once
you know a talk group’s ID, you won’t miss any of the
action.
If you’re a new scanner enthusiast, you may want to read
the first part of this manual and use your scanner in
conventional mode before you begin trunk tracking.
Understanding scanning fundamentals and its terminology
will make trunk tracking much easier. But if you’re already
an experienced scanner operator, you may want to go to
Trunk Tracking on page 36 now.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Feature Highlights
Trunk Tracking – Follow UHF High Band UHF
800/900 MHz trunked public safety and public
service systems just as if conventional two-way
communications were used.
Multi-Track – Track more than one trunking
system at a time and scan conventional and
trunked systems at the same time.
300 Channels – Program one frequency into each
channel. You must have at least one channel
programmed to use the Scan mode.
12 Bands, 10 Banks – Includes 12 bands, with
Aircraft and 800 MHz. 10 banks with 30 channels
each are useful for storing similar frequencies to
maintain faster scanning cycles or for storing all
the frequencies of a trunked system.
29 MHz-956 MHz – Indicates the range of
frequencies that can be searched within the bands
of your scanner.
Note: The frequency coverage is not continuous
and excludes the cellular band.
10 Priority Channels – You can assign one
priority channel in each bank. Assigning a priority
channel allows you to keep track of activity on your
most important channel(s) while monitoring other
channels for transmissions.
Preprogrammed Service (SVC) Scan – Allows
you to toggle through preprogrammed police,
fire/emergency, railroad, aircraft, marine, and
weather frequencies.
Unique Data Skip – Allows your scanner to skip
unwanted data transmissions and reduces birdies.
Memory Backup – If the battery completely
discharges or if power is disconnected, the
frequencies programmed in your scanner are
retained in memory.
Manual Channel Access – Go directly to any
channel.
LCD Back Light – An LCD light remains on for 15
seconds when
is pressed.
Autolight – Automatically turns the light on when it
finds a transmission.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Battery Save – In manual mode, your scanner
automatically reduces its power requirements to
extend the battery’s charge.
Attenuator – Reduces the signal strength.
SmartScanner™ – Automatically program your
BC 245XLT with all the frequencies and trunking
talk groups for your local area by accessing our
national database with your PC or just an external
modem. (No PC required)
Turbo Search – Increases the search speed to
300 steps per second. This applies only to
transmission bands with 5 kHz steps.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Where to Obtain More
Information
Before using your scanner, you must program frequencies
into available channels. The Betty Bearcat Frequency
Guide lists typical frequencies used around the U.S.A. and
Canada that you may program into your new scanner.
To obtain a copy of the frequency guide, contact one of the
following:
Uniden Parts Department (800) 554-3988 (Hours
are from 8:00 a.m. to 5:00 p.m. Central Time
Monday through Friday.)
Bearcat Frequency Hotline (937) 299-0414 (Hours
are from 9:00 a.m. to 5:00 p.m. Eastern Time
Monday through Friday.)
Local Dealer
Information on the Internet
If you have access to the Internet, you may want to visit
For more information about Uniden and our other products,
visit www.uniden.com
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Included with Your Scanner
If any of these items are missing or damaged, immediately
contact your place of purchase or Uniden Customer
Service at: (800) 297-1023, 7:00 a.m. to 7:00 p.m., Central,
Monday through Friday.
Antenna
Belt Clip
AC Adapter
Battery Pack
.com
ker
V
i
s
i
t
o
u
r
e
b
s
i
t
e
a
t
W
.trunktrac
www
Earphone
Operating Guide
ab BC
100-Channel T
860
le
XL
Bas
e
Scanner
-T
Base Scanner
Scanner
A
B
8
0
0
S
C
A
N
I
A
D
I
B
C
T
I
O
A
3
6
SCAN
IT
W
X
S
R
C
H
H
O
E
Y
-
/O
QEC
-
-
RORY
UBO
-
D
-
51
EHE
O
I
ARH
-
D
O
Y
M
E
OK
O
AUA
TrunkTracker
Frequency Guide
and Other Printed
Material
RS232C
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Setup
These are helpful guidelines when using your
new scanner:
If your scanner receives interference or electrical
noise, move the scanner or its antenna away from
the source.
If you need to improve reception, use an optional
antenna designed for multi-band coverage. (You
can purchase this type of antenna at a local
electronics store.)
Use the included earphone or an optional stereo
headset with proper impedance for private
listening. Read the precautions on the inside front
cover of this Guide.
Installing the Battery Pack
1. Open the cover.
2. Insert the battery
pack.
3. Replace cover and
press down until it
clicks into place.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Charging the Battery Pack
Use the AC Adapter/Charger to power the BC 245XLT
from an AC outlet.
Use only the supplied AC Adapter
(AD70U) or one of the optional power
cords (WZ1015 or WZ1017).
You can use your scanner while the battery charges. To
fully charge the battery, leave the AC Adapter/Charger
connected for 14 – 16 hours.
Note: Disconnect the AC Adapter/Charger from the unit
when charging is complete.
Low Battery Indicator
When the Battery Pack is low and needs to be charged,
the battery icon appears in the display. You will also hear a
beep every 15 seconds as an audible alert.
Adapter Safety Feature
The AC Adapter included with this scanner may be
equipped with a polarized line plug — a plug with one
blade wider than the other. This plug will fit into a power
outlet only one way. If you are unable to insert the
adapter’s plug into an outlet, try reversing the plug.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Flexible Antenna
Attach the flexible antenna to the
BNC connector.
Belt Clip
Do not tighten the screws too tight.
You can damage the case or clip.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Basic Operation
Note: Fold out the Front Cover to see the Controls and
Indicators while reading this Guide.
Turn the Scanner On
Turn the VOLUME control clockwise out of the detent
position. bc245 flashes twice in the display. The scanner
automatically starts scanning.
Setting the Squelch
To set the squelch, you must be in the Manual mode, and
you should not be receiving a signal on your scanner.
1. Press
until you do
not hear a signal.
2. Make sure that the
VOLUME is set to a
comfortable listening
level.
3.
Think of the Squelch Control as a gate. Turn
SQUELCH fully counter-clockwise. This raises the
“Squelch Gate” so high that only very strong signals
can get through.
4.
Turn SQUELCH fully clockwise until you hear a hiss.
This lowers the “Squelch Gate” so that everything
gets through—noise, weak signals, and strong
signals.
STRONG SIGNALS
MEDIUM SIGNALS
WEAK SIGNALS
NOISE
14
Download from Www.Somanuals.com. All Manuals Search And Download.
5.
Turn SQUELCH back counter-clockwise just until the
hiss stops. Now the “Squelch Gate” allows only clear
signals through.
STRONG SIGNALS
MEDIUM SIGNALS
WEAK SIGNALS
NOISE
Keylock
Key Lock prevents accidental key entries during
conventional scanning or while in trunk tracking mode.
1. To lock the keypad,
press and hold
1
2
3
4
5
6
7
8
9
10
until the
symbol
appears in the lower
right of the display.
2. To unlock the keypad,
press and hold
1
2
3
4
5
6
7
8
9
10
until the
symbol in
the lower right of the
display turns off.
LCD Back Light
Press and release to turn the LCD light on. It remains
on for 15 seconds and then goes out.
Auto Light
Press and hold
until you hear 2 short beeps. The
scanner will automatically turn the light on for 5 seconds,
whenever a transmission is found.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Programming
Before the BC 245XLT can begin conventional scanning,
you must program a frequency into at least one channel.
Repeat this procedure for each channel you want to
program.
1. Select frequencies
from your dealer, from
various sources on
the internet, or from
one of the guides
listed on page 9.
Here’s a list of sample
frequencies you
should try:
156.800 Marine Calling channel
155.340 Ambulance operations
155.280 Ambulance operations
155.160 Ambulance operations
462.950 Ambulance operations
462.5625 Family Radio Services (channel one)
2. Press
.
3. Select a channel.
a. Enter the channel
number.
b. Then press
.
1
2
3
4
5
6
7
8
9
10
16
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Enter the frequency.
a. Enter the frequency
number.
b. Then press
.
1
2
3
4
5
6
7
8
9
10
Note: To clear a mistake while entering the frequency,
press repeatedly until the display is cleared.
If you enter a
1
2
3
4
5
6
7
8
9
10
frequency which is
outside the scanner’s
frequency bands, a
distinctive beep
sounds and Error
appears in
the display.
Press
to Step 4.
and go back
(See the Table on page 3 or the Band List on the
back of the scanner).
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Duplicate Frequency Alert
If you enter a
1
2
3
4
5
6
7
8
9
10
frequency which is
stored in another
channel, you hear a
beep and the other
channel displays.
Press to clear and
start again.
Press
again to
store the frequency in
both channels.
Programming Tips
Do not program a weather frequency into one of
the channels, since weather channels transmit
continuously.
Use Service Scan feature to select the weather
information band.
Group similar frequencies into adjacent channels.
For example, program police frequencies in
channels 1 through 10 and fire/emergency into
channels 11 through 20, and so on.
Put the frequency that you listen to the most or the
most important frequency into a Priority channel.
To quickly program a series of channels, start with
the lowest number channel.
For example, when you are programming five new
frequencies into Channels 4 through 8, start with
Channel 4. After you finish programming a
channel, press
higher channel.
or
to go to the next
Write down your programmed channels and
frequencies in some convenient place in case the
scanner memory is lost.
If you want to download frequencies using
SmartScan feature, go to that section in this
manual.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Deleting a Stored Frequency
To delete a stored
frequency:
a. Select a
1
2
3
4
5
6
7
8
9
10
channel.
b. Press
c. Then press
.
.
Note: Channels with no frequencies are automatically
locked out.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Scanning
1. After programming
frequencies, simply
1
2
3
4
5
6
7
8
9
10
press to begin
scanning.
2.
The bank indicators selected for scanning appear in
the display, and the bank being currently monitored
flashes. You can deselect banks from active
scanning by pressing their number on your keypad.
The indicator for each deselected bank turns off, and
the bank’s channels are not scanned.
Note: One Bank must always be active. You cannot
deactivate all ten banks at the same time. If you try
to turn all the banks off, the first bank is
automatically selected.
To restore a bank to active scanning, press the
bank’s number on your keypad. The bank’s indicator
will display again.
3. During normal
scanning the scanner
SCAN
skips unprogrammed
or locked
out channels.
CHANNELS
1
2
3
4
5
6
7
8
9
10
Frequency
Locked Out
(L/O)
Frequency not
entered
4. When a transmission
is received, the LCD
back light comes on
for five seconds and
the scanner stops on
that channel, provided
that you have
1
2
3
4
5
6
7
8
9
10
selected the Auto
Light feature. When
the transmission
ends, scanning
resumes
automatically.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
If you want to stop on
a channel during
1
2
3
4
5
6
7
8
9
10
scanning, press
.
If you want to resume
scanning, press
1
2
3
4
5
6
7
8
9
10
.
To directly access a specific channel:
1. Press
.
2. Enter the channel
number you want
using the keypad.
3. Press
again.
RF Attenuation Feature
The BC 245XLT comes with an RF Attenuation feature. If
you’re near an unusually strong signal source, the signal
may overload the scanner. The scanner may stop
repeatedly on that signal and miss other transmissions.
The RF Attenuation feature works in all modes and
attenuates (reduces) the incoming signal strength by about
15 dB, preventing stronger signals from overloading the
scanner.
To turn RF Attenuation on:
1. Press ATT.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
2. You hear a beep, and
ATT appears in the
display begins
flashing.
Now all incoming
signal strength is
reduced.
To turn RF Attenuation off, just press ATT again. The ATT
icon goes out.
Setting the Delay Mode
A delay can be set for each programmed channel so that
when scan or search stops on a channel there is a brief
pause before the scanning cycle resumes. Delay must be
set for each programmed channel and it can be set when
your scanner pauses during a scan or when manual mode
is selected.
Delay in Scan or Search Mode
1.
2.
Press
search range and
press
or set a
.
When your scanner
stops on a channel
that you want to
delay, press
.
DLY displays and
scanning resumes two
seconds after the
transmission ends.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Delay in Manual Mode
1.
2.
Press
.
Select the channel
that you want by
entering the number
and press
Press
.
and DLY
displays indicating the
scanner will pause on
the channel when a
transmission is
received.
Channel Lockout
You can lockout any channel so it is not reviewed during
normal scanning. You can restore the channel to scanning
whenever you wish.
Lockout in Manual Mode
1. Press
.
2. Select a channel.
Enter the channel
numbers. Press
again.
Press
or
to change higher, or
to lower
the channel.
1
2
3
4
5
6
7
8
9
10
3. Press
to lockout
1
2
3
4
5
6
7
8
9
10
the channel.
L/O appears
in display.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Lockout in Scanning Mode
If the scanner keeps stopping on a particular channel due
to noise or too frequent transmissions, you may want to
keep that channel from scanning.
1. Wait until the scanner
stops at the channel.
1
2
3
4
5
6
7
8
9
10
2. Then press
3. The scanner
.
1
2
3
4
5
6
7
8
9
10
immediately resumes
scanning because the
locked out channel is
no longer in the
scanning sequence.
Lockout Tips
To quickly lockout a series of channels, start with
the lowest number channel.
For example, if you are locking out channels 4, 7,
8, 12, and 15, start with Channel 4. After selecting
channel 4, press
. Then press
one or more
times to step up to the next channel to be
locked out.
Record the locked-out channels in some
convenient place so you can restore them.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Restore a Locked Out Channel
1. Press
.
2. Select a locked out
channel.
a. Enter the channel
number.
b. Then press
again.
1
2
3
4
5
6
7
8
9
10
3. Press
to unlock
1
2
3
4
5
6
7
8
9
10
the channel. The L/O
icon goes out.
Restore All Locked-Out Channels
You can restore all locked-out channels in a bank only
when a bank is selected for scan. If you have deselected a
bank and you want to restore all of its locked-out channels
using the steps below, you must press
the number of the bank on your keypad.
and then press
1. Press
.
1
2
3
4
5
6
7
8
9
10
Note: You must be in
Manual mode before
restoring all
locked-out channels.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Press and hold
about two seconds.
for
You will hear two
beeps when all the
channels have
been restored.
Priority Scan
When Priority Scan is turned on, your scanner checks the
priority channel every two seconds for activity. If a signal is
present on the priority channel, your scanner monitors the
channel until the transmission ends, then resumes normal
scanning. You can designate one channel in each bank as
a Priority Channel.
To activate Priority Scan (in either the Manual or
Scan Mode):
1. Press
.
1
2
3
4
5
6
7
8
9
10
Note: If you have
1
2
3
4
5
6
7
8
9
10
locked out the priority
channel, this message
appears when you
select Priority mode.
2. Press
again at anytime to
deactivate Priority
Scan.
26
Download from Www.Somanuals.com. All Manuals Search And Download.
Changing the Priority Channel
You cannot eliminate the Priority Channel, but you can
change it to any of the 30 available channels in each bank.
1. Press
.
2. Select a new Priority
Channel.
a. Enter the channel
number.
b. Then press
again.
1
2
3
4
5
6
7
8
9
10
3. Press and hold
for two
seconds to designate
this channel as your
new Priority Channel.
Two beeps indicate
that the Priority
channel has changed.
Note: Priority in Trunking mode works just the same,
except instead of setting priorities for channels,
you set them for talk group ID’s.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Searching
Setting a Search Range
The BC 245XLT can search a specific frequency range to
find frequencies if you don’t have a frequency guide
available or if new stations have been added since your
guide was published.
1. Press
to stop
scanning.
2. Using your keypad,
enter the lowest
frequency of your
search range. For
example, enter
1
2
3
4
5
6
7
8
9
10
155.000 MHz.
3. Press
.
4. Using your keypad,
enter the highest
frequency of your
search range. For
example, enter
1
2
3
4
5
6
7
8
9
10
157.000 MHz.
5. Press
6. Press
.
.
Turbo Search
To increase the search speed from 100 to 300 steps per
second, press when the Search mode is active.
This only applies to the transmission bands which have 5
kHz steps. (Refer to the table on page 3 for the frequency
bands.) Search flashes in the display when Turbo search
is active.
To cancel Turbo Search, press
again.
28
Download from Www.Somanuals.com. All Manuals Search And Download.
Search Hold Feature
1. Press
at
1
2
3
4
5
6
7
8
9
10
anytime to stop the
search.
2. Press
move to the next
higher frequency.
to
1
2
3
4
5
6
7
8
9
10
Press
to
1
2
3
4
5
6
7
8
9
10
move down to the
previous frequency.
3. Press
to resume
searching.
Data Skip
A scanner will normally stop on any transmission it
receives. This means the BC 245XLT will stop on data
signals and unmodulated transmissions. You can
automatically skip many of these types of transmissions
during searches.
1. Press to activate
the data skip feature.
1
2
3
4
5
6
7
8
9
10
The
indicator
appears on the
display.
2. Press
again to
1
2
3
4
5
6
7
8
9
10
cancel the data skip
feature.
The
indicator
disappears from the
display.
When data skip is active, your scanner may pause
momentarily on an unwanted signal but will resume
searching in 2 or 3 seconds. Data Skip does not function
when the AIR Band is selected.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Frequency Skip
If a particular frequency continues to interrupt search
scanning, it is possible to set your scanner to skip the
frequency.
To skip a frequency,
press
.
Note: You can
program up to 50 skip
frequencies. The 51st
skip frequency
entered causes the
first skipped
frequency to unlock.
To cancel all skipped
frequencies, press
for 2 seconds.
Storing Search Frequencies
You can quickly store any frequency you find during
Search.
Caution: You must select the channel in which you will
store the frequency before entering the search
mode. Otherwise, you may erase a stored
frequency that you want to keep.
1. Press
.
2. Using your keypad,
enter the lowest
frequency of your
search range. For
example, enter
1
2
3
4
5
6
7
8
9
10
155.000 MHz.
3. Press
.
4. Using your keypad,
enter the highest
frequency of your
search range. For
example, enter
1
2
3
4
5
6
7
8
9
10
157.000 MHz.
30
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Press
6. Press
7. Press
.
.
when
the scanner stops at
the frequency you
want to store.
8. Press
to store the
1
2
3
4
5
6
7
8
9
10
frequency in the
channel you selected.
Note: After this step
you are in manual
mode.
9. To store another
frequency, select
another channel for
the new frequency by
pressing
or
or
.
10. Repeat steps 6
through 8 for all the
Search frequencies
you want to store.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
SVC Scanning
The Service
Scan feature allows you to toggle through six
bands preprogrammed for police, fire/emergency, railroad
aircraft, marine, and weather. The frequencies selected for
these bands are the most commonly used around the U.S.
1. Press
.
1
2
3
4
5
6
7
8
9
10
POLICE appears
beneath the blinking
channel number, and
a frequency displays.
2. After a two second
delay, scanning
begins.
1
2
3
4
5
6
7
8
9
10
Press
to start
scanning immediately
or to continue
scanning if you want
to skip a frequency.
3. Press
to scan the
1
2
3
4
5
6
7
8
9
10
FIRE bank.
4. Press
RR bank.
to scan the
1
2
3
4
5
6
7
8
9
10
When an active
channel is displayed,
the scanner will
alternate between the
frequency and the
Railroad channel
number.
5. Press
AIR bank.
to scan the
1
2
3
4
5
6
7
8
9
10
32
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Press
to scan the
1
2
3
4
5
6
7
8
9
10
MRN bank.
When an active
channel is displayed,
the scanner will
alternate between the
frequency and the
Marine channel
number.
7.
Press
WX band.
to scan the
1
2
3
4
5
6
7
8
9
10
Note: It’s possible to
receive more than one
weather broadcast in
your area. If the
broadcast sounds
weak or distant, press
again to look for a
closer station.
8.
To exit SVC Scan
.
mode, press
During search of one of the preprogrammed service bands,
press to stop the scan on a frequency. HOLD
appears in the display. Press
or
to move
to
up or down one programmed frequency, or press
resume scanning.
Note: If you want to remain on a channel until a
responding transmission is received, press
activate the two second delay feature.
to
33
Download from Www.Somanuals.com. All Manuals Search And Download.
SVC Scan Lockout
Follow these steps to lockout frequencies during Service
scanning:
Note: You cannot lockout weather frequencies.
1. Press
to stop
1
1
1
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
7
7
7
8
8
8
9
9
9
10
10
10
the Service Scan.
2. Press
.
3. Press
to resume
scanning.
Note: You can lockout up to 20 frequencies in SVC
Scan mode. The 21st locked out frequency
entered causes the first locked out frequency to
unlock.
To cancel the lockout press
again.
To restore all lockout frequencies, press and hold
about two seconds. You will hear two beeps when all
frequencies have been restored.
for
34
Download from Www.Somanuals.com. All Manuals Search And Download.
Programming with SVC Scan
Follow these steps to program frequencies into a channel
during Service scanning:
1. Select a channel you
want to program.
1
2
3
4
5
6
7
8
9
10
Note: If a frequency is
already stored in the
channel you select it
will be erased when
you save the new
frequency.
2. Press
repeatedly
to select Service Scan
mode you want.
3. Press
to begin
scanning.
4. When SVC Scan
stops on a frequency
you want, press
.
5. Press
frequency in the
channel you selected.
to store the
1
2
3
4
5
6
7
8
9
10
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Trunk Tracking
Your BC 245XLT is designed to track Motorola Type I,
Type II, Hybrid, SMARTNET™, PRIVACY PLUS™, and
EDACS analog trunking systems* on any band. When
tracking these types of systems, you may want to
remember these important points:
Your scanner defaults to monitor Motorola Type II
systems; however, you can change this if the
system in your area is different. (The types of
systems are discussed below.)
The frequencies for many of the trunked public
safety systems are listed in the TrunkTracker™
National Public Safety Trunked System Frequency
Guide included with your BC 245XLT scanner.
If you have internet access, you can visit
www.bearcat1.com/free.htm for current
news and frequency information about Trunk
Tracking Scanning.
You may experience slight interference in some
900 MHz frequencies, which may be reduced by
moving away from strong transmission sources.
*
Motorola, SMARTNET, and PRIVACY PLUS are trademarks of Motorola
Inc. EDACS is a registered trademark of the Ericsson Corporation.
Types of Trunking Systems
Trunking systems divide a few frequencies among many
different users, but the way that each system does this is
slightly different. There are really two types of trunking
systems (other than EDACS) which are important when
using your TrunkTracker™ scanner. These are usually
referred to as Type I and Type II systems. Type I only
occurs on some 800 MHz systems. All VHF, UHF and
900 MHz trunking systems (other than EDACS)
use Type II.
One important distinction between these two systems is
the amount of data transmitted by each radio when its
push-to-talk button (PTT) is pressed. Every radio in a
trunked system is assigned a unique ID so the central site
computer can identify it when it’s used. Both Type I and
Type II systems place radios (or radio users) into groups,
called talk groups, and these talk groups are also assigned
unique IDs. Some radios have access to only one talk
36
Download from Www.Somanuals.com. All Manuals Search And Download.
group, while others have access to many talk groups. The
talk group (s) each radio can access is called the radio’s
affiliation (s).
In a Type II system, when someone uses their radio, only
the radio ID is transmitted when PTT is pressed, whereas
in a Type I system the radio ID and its current affiliation are
both transmitted when PTT is pressed.
Why the difference? Type II systems are slightly more
advanced because the central computer maintains a
database which is used to determine each radio’s
affiliation (s). Changes to a Type II system are easier than
Type I because the system manager only need update the
database instead of reprogramming individual radios.
Another difference between the systems is that Type I
systems are arranged in a Fleet-Subfleet hierarchy. For
example, it’s possible for a city using a Type I system to
designate 4 Fleets, each with 8 Subfleets. Their fleets
might be the Police Department, the Fire Department,
Utilities, and Administration. The Police may decide to
further divide their fleet into subfleets such as Dispatch,
Tactical Operations, Detectives, North, South, East and
West Side Patrols, and Supervisors. All the available police
radios would then be assigned to one of the police
subfleets. Determining the exact Fleet-Subfleet hierarchy
for a particular area is referred to as Fleet Map
Programming, which is discussed further in this manual.
The disadvantage of a Type I system is that when PTT is
pressed, the brief burst of data must contain the radio’s ID
and its Fleet and Subfleet. This is three times the amount
of data a Type II system radio sends, and as a result
Type I systems usually accommodate fewer users than
Type II systems.
Even though there are many Type II systems, Type I
systems are still in use. There are also Hybrid systems
which are a combination of both Type I and Type II. Your
scanner defaults to monitor Type II systems, but it’s
possible to select a Preprogrammed Fleet Map or create a
Custom Fleet Map for your area.
For VHF and UHF Type II trunking systems, you will need
to know the base and offset frequency. See page 60
for details.
37
Download from Www.Somanuals.com. All Manuals Search And Download.
EDACS Tracking
TrunkTracker II now allows tracking of EDACS trunked
systems. Until now these widely used systems have been
almost impossible to monitor with a conventional scanner.
With your TrunkTracker II listening to EDACS is
remarkably easy, and perhaps even easier than
conventional scanning.
EDACS systems use “Transmission Trunking”, which
means that each transmission is assigned a new
frequency. As the conversation moves through the
system’s frequencies, your TrunkTracker II automatically
follows it.
This graph depicts a 30 second sample of transmission in
an EDACS trunked system, showing the frequency
transitions that a particular radio conversation might use.
Note: Many 900 MHz EDACS trunking systems (such
as those used by some utilities) utilize a control
channel that cannot be tracked with
the BC 245XLT.
38
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting the Squelch
Since Squelch is automatically adjusted in trunking mode,
it isn’t necessary to manually adjust the squelch control
while trunk tracking. However, the squelch setting you
select before you begin trunk tracking can affect how fast
your scanner acquires the data channel, and, in some
instances, the squelch setting can prevent your scanner
from acquiring the data channel at all.
Set SQUELCH in this
position before
selecting a
trunking bank.
Note: You can
change this
recommended setting,
if necessary, to
provide better
performance in
your area.
Programming Trunking Frequencies
Before you start programming your scanner to track a
trunked system, consider the following:
You can only program one trunking system in each
bank of your scanner.
Trunking frequencies must be entered while in the
Trunking Programming mode.
If you’re in the Trunking Programming mode, you
cannot select channels in other banks.
For example, if you are programming Bank 4, you
can only select channels 91-120 with the
or
keys.
IMPORTANT: If you are programming an EDACS
trunked system, you must enter the frequencies in
a specific order. Check the frequency guide
included with the radio and the listed web sites
for details.
39
Download from Www.Somanuals.com. All Manuals Search And Download.
The first step in tracking a trunked system is storing the
frequencies in one of the 10 available banks in
your scanner.
1. Press
second.
for 1.5
You will hear two
beeps, and BANK and
TRUNK will begin to
flash in the display.
2. Select the Bank you
want to store the
frequency, by
pressing 1 through 0.
3. Choose the system
you want to track.
Use
or
to choose the
system, and press
.
List of trunking options as follows:
E2 800
E2 900
E2 Hi
(Type II 800 MHz)
(Type II 900 MHz)
(Type II VHF 137-174 MHz) *
E2 UHF (Type II UHF 406-512 MHz) *
Ed
E1
(EDACS )***
(Type I 800 MHz) **
* Requires programming of a base and an offset frequency.
See appropriate section.
** Requires programming of a fleet map. See section on
Programming a Fleet Map.
*** Requires programming of frequencies in exact order
and location.
40
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Use the keypad to
enter a frequency for
the trunked system.
For example, enter
856.2625 (Type 1), or
enter a frequency of
the system you’re
going to track.
Note: To clear a mistake while entering a
frequency, press
twice, and start over.
Then press
.
If the frequency is out
of the range of the
system chosen in this
step, an error
message displays.
Press
to Step 3.
and go back
5. Press either
to select the
next channel in
or
the bank.
6. Repeat steps 4 and 5
until all frequencies
have been entered.
7. Press
to begin
1
2
3
4
5
6
7
8
9
10
BANK
TRUNK
searching the bank
you’ve programmed.
SCAN
Then select the
programmed bank
using the keypad.
41
Download from Www.Somanuals.com. All Manuals Search And Download.
Searching a Trunked Bank
If programming a Type I system, you cannot Scan the
trunking bank you just programmed unless you enter talk
groups into memory. See ahead for details. With the
search function, you’ll be able to find all the active talk
groups within the trunked system.
Once the data
channel is acquired,
the scanner begins
trunk tracking. Talk
group ID’s, which
represent different
service groups, begin
to display.
While searching, you won’t know exactly who the ID’s are
assigned to unless you listen awhile or until ID lists are
available in frequency guides or on internet sites. However,
it usually only takes a few minutes to figure out police, fire,
and emergency medical personnel. Other IDs may take
some time, but determining who each ID represents is half
the fun of TrunkTracker™.
Changing the Display Mode
While monitoring a trunking bank in any of the trunk
modes, press to change the display mode. You can
display one of the following conditions:
Current Scan List
Current Active Banks
Repeater Activity Indicators
You will find more information on these channel activity
indicators later in this section.
42
Download from Www.Somanuals.com. All Manuals Search And Download.
Frequency Find Mode
Press the
while
a talk group ID is active
and the display will flash
the frequency on which that
talk group is transmitting.
Press and hold
for
two seconds and the display
will automatically flash the ID
and the frequency alternately
until you set the condition by
pressing the
key again.
Direct Entry ID Hold Mode
During Search mode, you can hold on an ID without
entering it into memory.
1. When a talk group is
active, press
to stop the
search mode.
2. Use the keypad to
enter the ID you want.
Channel number
flashes in the display.
3. Press
again.
HOLD flashes in the
display.
4. Press
to return to
Search mode.
Note: The ID Hold mode works in Scan List mode, and
the steps are the same; however, SEARCH
doesn’t appear in the display.
43
Download from Www.Somanuals.com. All Manuals Search And Download.
ID Lockout
Like conventional scanning, it’s possible to lockout
unwanted traffic. This is particularly important in trunked
systems because in many areas, water meters, door
alarms, traffic signals, and other mechanical devices are
assigned IDs just like other users. Also some departments
scramble or encrypt their communications, and you may
want to lock out these unintelligible broadcasts.
To lockout an ID,
press when the
ID displays.
The ID is locked out,
and the next active ID
displays. You can
lockout up to 200 IDs.
Note: If you lockout an ID in Search mode, it is also
locked out in Scan List mode. Conversely, if you
lockout an ID while in Scan List mode, it is locked
out in Search mode. For information about Scan
Lists see page 48.
Restore a Single ID
To unlock a single ID, follow these steps:
1. Press and hold
until you hear two
short beeps.
2. Use
or
to select the ID you
want to unlock.
3. Press
.
The ID is unlocked
and the next locked ID
displays.
4. Press
to return to
the Search mode.
44
Download from Www.Somanuals.com. All Manuals Search And Download.
Restore all IDs
To unlock all locked out IDs at once, follow these steps:
1. Press and hold
until you hear two
short beeps.
2. Press
to unlock all
the IDs at once.
Note: If you unlock all the IDs, then the Scan List
to scan the IDs
to return to
Memory mode displays. Press
stored in your Scan Lists or press
the Search mode. For information about Scan Lists
see page 48.
3. Press
to return to
the Search mode.
Searching Tips
ID Delay Mode
Use the
key to select the Delay mode if it’s not
active. This mode holds an ID for 5 seconds while
you wait for a reply. Other groups may use the
system, but your scanner will only look for the ID in
the display.
Note: If you consistently miss responses while in
ID Delay mode, you may need to change the
default system type or change the fleet map you’re
using if you’re trying to track a Motorola Type I
system. For Motorola Type II or EDACS, if you’re
missing pieces of conversations, you’ve likely left
out one or more of the frequencies used by
the system.
45
Download from Www.Somanuals.com. All Manuals Search And Download.
Hold Mode
Press
to hold on a particular ID in the
display. You can hold a specific talk group, such as
fire department on-scene operations, no matter
which frequency the group uses.
Press to continue searching the entire
trunked system.
ID Monitor Mode
If you press and hold
for 2 seconds, until you
hear two short beeps, you will select the ID Monitor
mode. SEARCH begins flashing in the display, and
all active talk group IDs begin to display in
succession. You won’t hear conversations in this
mode, but this is an excellent way to determine
which talk groups are the most active.
Note: Locked out IDs display during ID Monitor
mode with the L/0 icon turned on.
Press to continue searching the entire
trunked system.
Channel Activity Indicators
The BC 245XLT has 20 Channel Activity Indicators to
visually display a trunked system’s activity when you select
delay, hold, scan etc. You’ll always know which
frequencies are in use and how much communication
traffic is occurring.
46
Download from Www.Somanuals.com. All Manuals Search And Download.
Each frequency you program in a trunking bank
corresponds to an activity indicator at the top of your
scanner’s display. The way in which the Activity Indicators
display provide you with information about the system
you’re tracking.
The indicator which
remains on, even if
when there is no
traffic, represents the
frequency being used
as the data channel.
If an indicator turns on
and you don’t hear a
conversation, then the
channel is probably
being used for a
telephone
interconnect call or a
private call. These
calls are not
monitored by your
scanner.
Note: The Scanner does not show activity bars for
private or phone interconnect calls for
EDACS systems.
The indicator which
flashes when an ID
displays represents
the frequency being
used by the talk
group.
If you’re holding on an
ID which isn’t active,
the activity indicators
will turn on and off as
other groups use the
system.
Note: If more than 20 channels are stored in a bank,
then the indicators represent multiple channels.
For example, if 28 channels are programmed, the
first 8 activity indicators each represent two
channels.
The display may change from showing channel
activity indicators to Scan List memory positions.
To restore to the previous setting, press
.
47
Download from Www.Somanuals.com. All Manuals Search And Download.
Scan Lists
Each bank of your BC 245XLT can be a trunk tracking
bank or it can be a conventional scanning bank. When you
designate a bank as a trunking bank, your scanner sets up
10 Scan Lists, which are simply lists used to store your
favorite IDs. Each list can contain up to 10 IDs, so you can
store a total of 100 IDs for each trunk tracking bank. (1000
if you use all banks as trunking banks!)
Scan Lists help you organize the trunking system users
into categories. For example, you might use List 1 for
police IDs, List 2 for fire department IDs, List 3 for
emergency medical service IDs, etc. Once IDs are stored
in lists, you can scan them like you scan conventional
frequencies. You can program your scan lists either
manually or during trunking search mode.
www.bearcat1.com/free.htm for a complete list of talk
groups for your area that you can program into your
Scan Lists.
Programming ID Scan Lists Manually
1. Press
2. Use
.
and
to select the
Scan List location you
want to program. For
example, select the
second memory
location in the first
scan list.
48
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Enter the Type II ID
you want to store, and
press
.
—OR—
To enter a Type I ID:
a. Enter the fleet
number.
b. Press
c. Enter the subfleet
.
number, and
.
press
—OR—
To enter an
EDACS ID:
a. Enter ID you
want to
1
2
3
4
5
6
7
8
9
10
TRUNK
store. Use the
for
the “dash”.
b. Press
.
If you wish to store
Decimal style ID,
press and hold
until you hear 2
short beeps before
step a.
Note: To clear a mistake while entering an ID,
press
twice, and start over.
4. Press
or to
select the next Scan
List location.
49
Download from Www.Somanuals.com. All Manuals Search And Download.
An icon will show an “E” in the display when you have
programmed an EDACS system.
Note: The BC 245XLT defaults to “AFS” talk group
displays for EDACS only. AFS describes most
systems in the following manner:
Using the sample talk group 01-011:
01 is the Agency Level (such as police)
01-01 describes the Agency and fleet level (such
as police patrol)
01-011 describes the Agency, fleet and subfleet
level (such as police patrol east side) of a
particular talk group
EDACS systems are organized in a logical way that keeps
related talk groups together. Your scanner is designed to
use this organization to make your scanning easy. It has
two new features, AFS and XPAND, to let you zero in on
just the part of the system you want to hear, whether it is
an individual channel or an entire department or city.
AFS Display
AFS (Agency-Fleet-Subfleet) is the numbering system
used in the TrunkTracker II to display and enter EDACS
talk groups. Systems differ, but AFS will help you
recognize and program them all. And AFS works together
with XPAND to provide a new kind of scanning flexibility.
XPAND
XPAND lets you expand or narrow searching and scanning
to one of 4 levels. By entering only the desired part of a
talk group, you can select 2048 talk groups, 128 talk
groups, 8 talk groups, or a single talk group. For example,
you might program every talk group in a police department
with just 4 key presses.
50
Download from Www.Somanuals.com. All Manuals Search And Download.
You can also enter or display EDACS talk groups in
decimal format (0-2047). Just press and hold
the scanner between AFS and decimal mode. But you
cannot use XPAND when in decimal mode.
to switch
You can program a specific talk group such as 01-011 into
Scan List memory, or, with AFS mode, you can program
the talk groups for an entire agency (there may be
hundreds) by pressing, for example:
01,
,
(all 01 groups will be scanned)
Or you can program all the talk groups within one fleet of
an Agency by pressing, for example:
01, , 01, (all 01 talk groups within the 01
Agency will be scanned)
You can also “Blockout” a large number of talk
groups by pressing
after entering an Agency or
an Agency and Fleet into memory. This is a very
powerful feature!
Note: In AFS mode, Agency numbers range from
00 through 15.
If you prefer to view and program talk groups in “decimal”
mode, press and hold
EDACS trunking bank and the display method will change.
It will stay changed until you press and hold again for
for two seconds while in an
two seconds while in EDACS operation. Decimal mode will
not work with partial talk groups entered in AFS mode into
Scan List memory.
For further details and examples, please see the Appendix.
51
Download from Www.Somanuals.com. All Manuals Search And Download.
ID Scan Mode
1. Press
to begin
scanning the lists you
have programmed.
If you haven’t
programmed any IDs,
SCAN displays but
your scanner cannot
stop on an active
conversation.
2. To remove a Scan
List from active
scanning, press the
number of the Scan
List on your keypad.
The Scan List
indicator turns off, and
the IDs in that list are
not scanned.
Note: One Scan List must always be active. If you
try and deactivate all the Scan Lists, Scan List 1
will automatically be active.
3. To restore a Scan List
to active scanning,
press its
number again.
4. Press
to return to
Trunk Tracking
Search mode.
To alternate your
display between the
trunking repeater
indicators and the
Scan List indicators,
press
.
52
Download from Www.Somanuals.com. All Manuals Search And Download.
Note: Once you press
or
trunking banks will change to that mode.
in one bank, all
Setting Priority in Trunking Mode
You can set priority in your trunking banks, just as you do
in your conventional ones. After you’ve set up your Scan
List, press
to activate it. The radio will default to
setting the first “channel” in each of your Scan List as a
priority. Since each trunking bank holds 10 Scan Lists of 10
memory channels each, channel 1, 11, 21, through 91 are
all default priorities. You can adjust which talk group in
each List is the priority by pressing and holding
.
It’s very similar to conventional priority although there is no
“interrupt” during the transmissions. Priorities are checked
in between transmissions.
With Priority on, you can hold on an ID in your Scan List,
such as Scan List 6, memory position 7, and the scanner
will check all the priorities in all the active Scan Lists every
few seconds and in between any transmissions on the ID
on which you’re holding. The lowest numbered priority will
be checked first. For example, the priority channel in List 1
will be checked before the priority in List 2, etc.
53
Download from Www.Somanuals.com. All Manuals Search And Download.
Programming Scan Lists During Search
To select a Scan List location and store an ID during
Search mode, follow these steps:
1. When your scanner
stops on an ID you
want to store, press
.
2. Use
or
to select the Scan List
memory location you
want, then press
.
3. Press to return to
Trunk Tracking
Search mode.
To let your scanner automatically store an ID in an
available Scan List location, follow these steps:
1. Press
when your
scanner stops on an
ID you want to store.
2. Press
to return to
Trunk Tracking
Search mode.
Deleting a Stored ID
To delete a stored ID:
a. Press
b. Then press
.
.
54
Download from Www.Somanuals.com. All Manuals Search And Download.
Moving between Scan List Memories
There are a number of ways to step and move through
your Scan List memories:
1. Press
repeatedly.
, then press
, Next press 0-9 (scan list number), then
2. Or, Press
or
.
3. Or, Press
press 0-9 (memory position). For example. To move to
Scan List 4, memory position 10, press:
, 4, 0,
Multi-Track
The BC 245XLT allows you to track more than one system
at a time. Here are some highlights of this new feature:
1.You can actually track up to 10 trunking systems at
one time!
2.You can trunk scan or search and scan conventional
frequencies at the same time.
3.You can program conventional frequencies in the same
bank as trunking systems. After the radio finishes checking
a trunked system for activity, it will conventionally scan the
other frequencies in the bank (remember, only trunking
frequencies are programmed in TRUNK mode).
To scan a mix of trunking and conventional banks, select
the banks you wish to be active with trunking off, then
press
. The radio will instantly begin scanning. If you
have not programmed a trunking bank with talk group ID’s,
you will receive an ERROR message for that bank. You
can switch to SEARCH mode and the scanner will search
for any active ID’s on the system.
55
Download from Www.Somanuals.com. All Manuals Search And Download.
Fleet Map Programming
If you have programmed a trunk tracking bank and select
, you will see user IDs display on your screen. Since
the BC 245XLT defaults to Type II systems, all the IDs will
appear as numbers. However, if you notice a mix of odd
and even user IDs, for example 6477, 2560, 6481, 6144,
1167, etc., then you are probably monitoring either a Type I
or EDACS system.
You may also notice that you’re missing responses when
you hold on an active ID. Unlike Type II and EDACS
systems, Type I/Hybrid systems require a Fleet Map that
sets specific Fleet-Subfleet parameters. It’s easy to select
a Fleet Map for your scanner; what isn’t always easy is
selecting or programming a map that matches your
particular area.
There are 16 preset Fleet Maps listed in the appendix that
you can choose, and these are usually a good place to
start when setting up a Type I/Hybrid trunk tracking bank. If
you choose a preset map and still have difficulty following
complete conversations, then you’ll have to program your
own Fleet Map.
Selecting Trunking Programming Mode
To change the system type which your scanner monitors,
you must be in the Trunking Programming mode. To select
this mode, follow these steps:
If you are in Conventional Scan mode:
1. Press and hold
.
You’ll hear two short
beeps and BANK and
TRUNK will begin to
flash in the display.
2. Select the trunking
bank you want to
program.
56
Download from Www.Somanuals.com. All Manuals Search And Download.
If you are in Trunking Scan mode:
1. Press to return to
conventional mode if
you have been
monitoring a trunking
bank. TRUNK icon
goes out.
2. Press and hold
until you hear two
short beeps.
You’ll hear two short
beeps and BANK and
TRUNK will begin to
flash in the display.
3. Select the trunking
bank you want to
program.
Selecting a Preset Fleet Map
1. Select the Trunking
Programming mode
and the bank you
want to change.
2. Use
or
to select E1.
Then press
.
3. Press
.
4. Use
or
to choose the map
you want. For
example, E1P2.
Note: It is required that the trunked frequency has
been programmed before selecting a preset
fleet map.
57
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Press
.
The scanner returns
to Programming Bank
selecting mode.
Note: You will now begin to see Type I
Fleet-Subfleet IDs. For example, 100-12, 100-9,
000-12, 400-8, etc. See User Defined Fleet Maps
in the Appendix for more information about
Type I IDs.
How do you know if the preset map is correct? You’ll have
to listen to see if you’re following complete conversations.
If not, you should try another preset map.
Programming a Fleet Map
You may want to read User Defined Fleet Maps in the
Appendix before programming a fleet map. It contains a
detailed explanation of Scanner Fleet Map Programming,
as well as a table listing the Fleet Map Size Codes.
1. Select the Trunking
Programming mode
and the bank you
want to change.
2. Use
or,
to choose E1, and
press
.
3. Press
.
4. Use
or
to choose USr.
5. Press
6. Use
.
or
to select the size code
for the first block.
58
Download from Www.Somanuals.com. All Manuals Search And Download.
7. Press
.
The next available
block displays.
8. Repeat Steps 6 and 7
until you have
selected a size code
for each block.
For specifics about
each size code, see
Fleet Map Size Codes
in the Appendix.
9. Press
.
The scanner exits the
Trunking
Programming mode,
acquires the data
channel, and begins
searching using the
map you’ve
programmed.
Note: It is required that the trunked frequency has
been programmed before programming a
fleet map.
Programming a Hybrid System
A Hybrid system is simply a Type I system with some
blocks designated as Type II blocks. To program a Hybrid
system, follow the steps listed in Programming a Fleet Map
in the previous section. However, if you want a block to be
Type II, select Size Code S-0.
When you begin searching a trunking bank with a Hybrid
Fleet Map, you will see both types of system Ids. That is,
Type II Ids usually appear as an even number without a
dash; Type I Ids appear as a three or four digit number,
followed by a hyphen, followed by a one or two digit
number. See page 68 for more information.
59
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting the Base and Offset frequencies for
Motorola VHF/UHF trunked systems
To properly track Motorola VHF and UHF trunked systems
you must enter what is known as the “base” and the
“offset” frequencies for each system. To find these out,
www.bearcat1.com/free.htm and other web sites and
frequency resources.
To enter the base and offset frequency:
1. Select the bank into which you want to program the
trunking system.
2. Select the system type (Type II VHF or Type II UHF)
by scrolling through the system selector.
3. Enter the frequencies for the system.
4. Press
for UHF)
. (406.000 is the default bAS frequency
5. Press . Or, enter a new base frequency and
press
.
6. Press . The screen will show the OFS (offset)
frequency default of 50 kHz.
7. Press
50 or 100.
. Or, enter another offset including: 12.5, 25,
8. Press
to begin trunking.
Note: If the system is not tracking properly, you may
need to try a new base or offset frequency or you
may be missing frequencies from the system.
60
Download from Www.Somanuals.com. All Manuals Search And Download.
Toggling the Status Bit
On Type II trunking systems there is a method by which
specialized types of communications utilize unique talk
group numbers. An emergency call will occur on a unique
talk group from its primary assignment, for example.
Because the BC 245XLT defaults to Status-Bit On mode,
you never need to worry about missing these
transmissions. If you’ve programmed talk group 33264 into
Scan List memory, for example, and there is an emergency
call within the group, you will hear it on 33264. The only
time you may wish to turn Status Bits off is if you’re trying
to figure out the proper fleet map of a Type 1 trunking
system. To turn Status Bits off, press and hold
for two
seconds while in the Motorola system you wish to adjust.
(This feature does not apply to EDACS operation within
the scanner.) Then use
setting (on to off) and press
or to change the
to program your change.
61
Download from Www.Somanuals.com. All Manuals Search And Download.
Remote Interface
You can communicate and program your BC 245XLT in
numerous ways with peripheral devices using the RS232C
port. This radio offers the following modes:
SMARTSCAN MODE
Automatically load frequencies, trunking talk
groups and fleetmaps from the Uniden National
Frequency Database server into your scanner
using an external modem or an internal modem
included with a PC.
REMOTE (PC Control) MODE
Program and control your scanner remotely from a
PC using third party software (see the flyer
included in the box).
CLONE MODE
Clone all the frequencies and trunking talk groups
and fleet maps programmed into your scanner to
another BC 245XLT.
Connecting the scanner
Scanner to PC
BANK
TRUNK
1
2
3
4
5
6
7
8
9
10
ATT
BATT
888888.8888
DATA POLICE FIRE RR
AIR MRN WX
SCAN SEARCH PRI HOLD DLY L/O
Plug the smaller end of the supplied RS232C cable into the
remote port which is on the right side of the scanner.
Plug the other end of the cable (DB-9 serial connector) into
a personal computer’s serial port. A few PC’s may require
an adapter, most will not. Of course, make sure your PC is
turned on.
To use SmartScan mode with an internal modem, you will
need a small custom software program to allow the serial
port to talk with the internal modem and act as a simple
“pass through” device. To download this free program, go
to Uniden’s website, look up under Scanners
“SmartScanner” or the BC 245XLT scanner, for the
62
Download from Www.Somanuals.com. All Manuals Search And Download.
SmartScanner software. Run this program and it should
automatically set the port setting for you (although you can
override the settings). Make sure that you have a phone
line plugged into the modem jack on the back of your PC
and your scanner is connected to the serial port of the PC
using the supplied cable.
To use the Remote (PC Control) mode, you must purchase
third party software and use as directed. Make sure that
your scanner is connected to the serial port of the PC using
the supplied cable.
Scanner to External Modem
Plug the smaller end of the supplied RS232C cable into the
remote port which is on the right side of the scanner.
Plug the other end of the cable (DB-9 serial connector) into
the external modem. You may need a DB-9 to DB-25 null
modem adapter, available at most computer stores. Of
course, make sure your external modem is turned on.
Make sure that you have a phone line plugged into the
modem jack on the back.
Scanner to Scanner
Plug the smaller end of each of the supplied RS232C
cables into the remote ports which are on the right sides of
each of the two scanners.
Plug the other ends of the cables (DB-9 serial connector)
together using a DB-9 to DB-9 null modem adapter,
available at most computer stores.
63
Download from Www.Somanuals.com. All Manuals Search And Download.
SmartScan Mode
You can automatically download frequencies, talk groups,
and fleetmaps from the Uniden National Frequency
Database server. After connecting the scanner to a modem
using the Scanner to PC or Scanner to External Modem
steps (see page 62), turn the radio off. Press and hold
REMOTE key and turn the radio on. Then release the key.
bc245 will flash on the display.
1. The following screen
appears. (SmartScan
Mode) To select
SmartScan mode,
press
or
.
2. The following screen
appears.
3. Before starting the
frequency download,
you must enter your
zip code.
Using the keypad,
enter the ZIP code for
the area you will be
using your scanner.
For example if your
ZIP code is 02135.
4. Press
key, the ZIP
code is stored into
memory. The dial-in
telephone number
appears in the display.
Note: If you want to prevent some banks from being
overwritten by the frequency download, go to
Program Lock. (See page 66)
5. Press
key. The
scanner dials to the
database server.
64
Download from Www.Somanuals.com. All Manuals Search And Download.
6. If the connection is
successful, the
scanner starts
frequency
downloading.
7. donE will be
displayed when your
downloading is
completed.
8. To start the scanner,
you must turn the unit
off/on.
If downloading is not successful, one of the following error
messages will appear.
Err01: MODEM ACCESS ERROR
Err02: NO CARRIER
Err03: TELEPHONE LINE BUSY
Err04: NO ANSWER
Err05: SERVER CONNECT ERROR
Err06: DATA IDLE TIME OUT
NOTE: If the scanner does not display LoAd (see
step 6), disconnect the access by pressing
Then, make sure the modem is connected
properly, and try again.
.
NOTE: The number preprogrammed into your scanner
for downloading frequencies is 1-900-225-4822.
There is a $0.99 per minute charge for using the
SmartScan database.
The frequencies in the SmartScan database are
updated, at a minimum, every 6 to 12 months. To
get current frequencies, as well as
special /sporting event frequencies, regularly
update your scanner by using SmartScan.
NOTE: If you are unable to dial a “900” number, check
with your local phone company to find out if you
have a “900” block on your phone line. This will
prevent you from dialing to the server.
65
Download from Www.Somanuals.com. All Manuals Search And Download.
Program Lock
SmartScanner will overwrite frequencies that you have
already programmed into your scanner. To save the
previously programmed frequencies, you can lock out
specific banks prior to calling the database as follows:
1.
After you enter your
zip code, press
.
2.
With the phone
number on the
display, press
.
PrgLoc appears in
the display.
3.
Press the bank
numbers using the 1-9
and 0 key (for bank
10) that you wish to
lock out from
programming so that
they will not be
overwritten during the
download.
4.
5.
6.
Press again. The
zip code is displayed.
Press . The phone
number appears.
Press
the call.
to place
66
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu for SmartScan
Press key and you can change several parameters
used for SmartScan.
Transfer speed 300, 1200, 2400, (9600) bps
Flow control setting (Xon/Xoff), RTS/CTS, Off
Dial type
(TONE), PULSE
Transfer Speed
You can choose the following transfer speeds.
300,1200,2400,(9600),14400 bps
9600 is the default.
Press
to exit.
Flow Control
You can choose the following flow control settings.
Xon/Xoff is the default.
The initial display appears.
Press
for RTS/CTS,
again for non
Press
flow control.
Press
when desired setting is displayed.
Dial Type
You can choose the Dial Type setting.
Tone is set as a default.
You can change it to PULSE by pressing
.
67
Download from Www.Somanuals.com. All Manuals Search And Download.
SMARTSCANNER TIPS
There are literally hundreds of thousands of public safety
radio licenses in the United States. The editors of the
Uniden National Frequency Database have poured over
these records to provide you with the most accurate
possible download of frequencies for whichever area of the
country you desire. Because of the volume of data, and
because some systems operate on expired licenses or
digital radio systems (which are not included in the dataset
as they cannot be monitored), we cannot guarantee that
you will receive every active public safety frequency in your
area.
If you find any flaws in your data and you would like to offer
suggestions, please e-mail them to us at
[email protected] or mail them to us at
SmartScanner National Database, P.O. Box 610428,
Newton Highlands, MA 02468. Due to the volume of mail
we receive, you may not receive a reply.
The SmartScanner database downloads frequency and
trunking talk groups (if applicable for your area) to the
scanner using the following order:
1. All licenses within your zip code.
2. All licenses within your community (with more than one
zip code)
3. All your county licenses (such as County Sheriff)
4. All the licenses for all the communities within your
county (in random order).
5. Statewide licenses (such as Highway Patrol, state
forestry, DOT, but not trunking)
6. National licenses (such as common ambulance, marine,
and Family Radio Service channels).
Look at the web sites Uniden.com and Trunktracker.com
for further information. The downloads are not available
through the Internet at this time.
68
Download from Www.Somanuals.com. All Manuals Search And Download.
A few notes about the frequency download order:
1. The scanner fills up less than its allotted 300 channels if
there are not more than 300 of the above types of licenses
in your area.
2. If there are more than 300 of the above listed types of
licenses, or you have locked-out some banks prior to the
download using the Program Lock feature, the scanner
may run out of memory locations and you may not, for
example, receive part or all of your county, state or
nationwide data.
3. If you wish to also receive a download of frequencies
and talk groups from an adjacent county, lock those banks
you wish to keep, shut the scanner off, turn it back on
again and enter the SmartScanner download mode. Then
enter a zip code from a community within the adjacent
county.
4. The SmartScanner editors used their best efforts to
delete digital and MDT (mobile data terminal) computer
records from the database; however, it would be
impossible to delete them all. Therefore, you may hear
some non-voice transmissions on the frequencies
downloaded into your scanner. Make sure you have
TRUNK mode on to see if these are control channels for a
trunking system. If not, then you should lock these
frequencies out or delete them by entering a new
frequency or entering 0,
.
5. Important: After the download, be sure to press the trunk
key to see if you have trunk systems now loaded for your
area. The BC 245XLT cannot track such systems unless
the trunking mode is on. Performance of the scanner is not
hindered if you have TRUNK mode on and you do not have
a trunk system programmed.
6. If you have a trunk system programmed (you can tell by
seeing if the display shows Id SCAN at any time), be sure
to put the radio into Trunk Search mode at some point to
discover new talk groups within the trunk system that
have not been pre-programmed into the
SmartScanner database.
7. The database will be updated every 6 to 12 months at
a minimum.
69
Download from Www.Somanuals.com. All Manuals Search And Download.
Remote (PC Control) Mode
You can program and control your scanner remotely from a
PC using third party software. After connecting the scanner
to a PC using the Scanner to PC steps (see page 62), turn
the radio off. Press and hold REMOTE key and turn the
radio on. Then release the key. bc245 will flash on the
display.
1. The following screen
appears.
2. To control your
scanner using a PC,
press . Or, press
or
until this screen is
displayed. Then press
to select the
Remote mode.
3. Use the third party
software as directed.
Start Remote Mode
Turn off the power, then turn it on again.
Press REMOTE key,
until you hear two
short beeps.
REMOTE mode
is selected. To
distinguish from
Normal operation
mode, “KEYLOCK”
icon flashes.
1
2
3
4
5
6
7
8
9
10
BANK
DATA
SCAN
PRI
During REMOTE
Control mode, the
scanner will ignore
any key (except
REMOTE key).
For information on purchasing third party software to
program and control your BC 245XLT, see the flyer
included in the box with this radio.
70
Download from Www.Somanuals.com. All Manuals Search And Download.
PC Control Parameter
For your information:
BPS rate : 2400/4800/9600/19200 bps
Start/Stop : 1 bit, 1 bit
Data Length : 8 bit
Parity bit
Code
Flow Control : None
: None
: ASCII code
Return Code : Carriage Return only
Change Transfer Speed
1. While pressing
REMOTE key, turn
the power on.
“bc245” flashes on
the display, then
changes to SCANr.
2. Press . Or, press
or
until this screen
appears. Then press
to display Transfer
Speed.
3. To change the
transfer speed, press
and
Then press
select.
.
to
71
Download from Www.Somanuals.com. All Manuals Search And Download.
Clone Mode
You can clone the frequency data of one BC 245XLT
scanner to another. After connecting the two scanners,
using the Scanner to Scanner steps (See page 63), make
sure the scanners are turned off. On each scanner, press
and hold REMOTE key and turn the radio on. Then release
the key. bc245 will appear on the display.
1. On each scanner,
press
or
or
until this
screen is displayed on
both scanners. Then
press
(Clone Mode)
.
2. Determine the
scanner that has the
frequency data that
you want to transfer.
This one must be set
up as the “First” unit,
and the other must be
set as the “Clone”.
3. On the scanner that
has the desired
frequency data, press
the
key until
FirSt appears in
the display.
4. On the scanner that is
the “Clone”, press the
key until ClonE
appears in the
display.
5. Press the
key on
both scanners. The
data transfer is started
from the “First” unit to
the “Clone” unit.
72
Download from Www.Somanuals.com. All Manuals Search And Download.
During the data
transfer, FirSt”
and CLONE
characters will
continue to flash.
When the data
transfer is completed,
donE displays.
If the data transfer is
not successful, the
following error
message
will appear.
73
Download from Www.Somanuals.com. All Manuals Search And Download.
Care and Maintenance
General Use
Turn the scanner off before disconnecting the
power or replacing the batteries.
Always write down the programmed frequencies in
the event of memory loss.
If memory is lost, simply reprogram each channel.
The display shows 000.000 in all channels when
there has been a memory loss.
Always press each button firmly until you hear the
entry tone for that key entry.
Location
Do not use the scanner in high-moisture
environments such as the kitchen or bathroom.
Avoid placing the unit in direct sunlight or near
heating elements or vents.
If the scanner receives strong interference or
electrical noise, move it or its antenna away from
the source of the noise. If possible, a higher
elevation, may provide better reception. Also try
changing the height or angle of the antenna.
Cleaning
Disconnect the power to the unit before cleaning.
Clean the outside of the scanner with a mild
detergent. To prevent scratches, do not use
abrasive cleaners or solvents. Be careful not to rub
the LCD window.
Do not use excessive amounts of water.
74
Download from Www.Somanuals.com. All Manuals Search And Download.
Repairs
Do not attempt any repair. The scanner contains
no user serviceable parts. Contact the Uniden
Customer Service Center or take it to a qualified
repair technician.
Birdies
All radios can receive “birdies” (undesired signals).
If your scanner stops during Scan mode and no
sound is heard, it may be receiving a birdie. Birdies
are internally generated signals inherent in the
electronics of the receiver.
Press
to lockout the channel, and then press
to resume scanning.
75
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
If your BC 245XLT is not performing properly, try the
following steps.
Problem
Suggestion
Scanner won’t work.
1. Check the connections at both ends of
the AC Adapter.
2. Turn on the wall switch of your room. You could
be using an outlet controlled by the wall switch.
3. Move the AC Adapter to another wall
outlet or replace the battery pack.
Improper reception.
1. Check the antenna connection or move
and reposition the antenna.
2. Move the scanner.
3. You may be in a remote area which could require
an optional multi-band antenna.
Check with your dealer or local electronics store.
Scan won’t stop.
1. Adjust squelch threshold - refer to page 14,
Setting the Squelch.
2. Check the antenna connection.
3. Check to see if many of the channels are locked
out. If so, the scanner has less chance of finding
an active channel.
4. Review each channel’s frequency to see if it is still
stored in memory and is correct.
5. It’s possible that none of the programmed
frequencies are currently active.
Scan won’t start.
1. Press the
key again.
2. Adjust the SQUELCH control.
3. Check to see if all channels are locked
out.
Weather Scan won’t work.
1. Adjust squelch threshold - refer to
page 14, Setting the Squelch.
2. Check the antenna.
76
Download from Www.Somanuals.com. All Manuals Search And Download.
If you experience difficulty while in TrunkTracker™ mode,
try the following steps.
Problem
Suggestion
Scanner won’t track the trunked 1. May not be a system which can be tracked by
system.
your scanner.
2. Missing the data frequency.
3. Change to a Type 1 Scanner setup.
Review Fleet Map Programming on page 56.
Scanner won’t stop during Scan 1. No IDs have been programmed.
List mode.
2. The IDs you have stored are not active.
Scanner will not acquire data
channel.
1. Adjust the squelch for trunking mode.
See page 39.
2. Missing the frequency used for the data
channel. Check your frequency list.
Missing replies to conversations. 1. Change to a Type 1 Scanner setup.
Review Fleet Map Programming on page 56.
2. Try another Preset Fleet Map or Program
your own Fleet Map.
3. Check to see that all of the systems
frequencies have been entered.
Channel Activity Indicators are
flashing but no sound is heard.
1. May be a private or telephone
interconnect call, which are intentionally
blocked by your scanner.
2. The ID in your display is not active.
Scanner not tracking an EDACS 1. Logical channel numbers ( frequencies)
system properly.
for the system are not programmed in the correct
order. Check frequency resources and reprogram.
2. Not all frequencies for the system are
programmed. Check frequency resources.
If you still cannot get satisfactory results while using your
scanner or if you want additional information, please call or
write the Uniden Parts and Service Division. The address
and phone number are listed in the Warranty at the end of
this manual. If you would like immediate assistance, please
call Customer Service at (800) 297-1023.
If you have internet access, you can visit
www.bearcat1.com/free.htm for additional information.
77
Download from Www.Somanuals.com. All Manuals Search And Download.
Specification
Certified in accordance with FCC Rules and Regulations
Part 15, Subpart C, as of date of manufacture.
Channel:
Banks
300
10 (30 channels each)
Service Bands: 5-preprogrammed search bands (including the
NOAA Weather Service band)
Frequency
Range:
29.0-29.7 Mhz 10 Meter Amateur Band
29.7-50.0 Mhz VHF Low Band
50.0-54.0 MHz 6 Meter Amateur Band
137-144 Mhz Military Land Mobile
144-148 MHz 2 Meter Amateur Band
148-174 MHz VHF High Band
Above bands in 5 kHz steps
108-137 MHz
406-420 MHz
420-450 MHz
450-470 MHz
470-512 MHz
806-956 MHz
Aircraft Band
Federal Government
70 cm Amateur Band
UHF Standard Band
UHF “T” Band
“800” Band
Above bands in 12.5 kHz steps
Operating
Temperature: -20°C to +60°C
Scan Rate:
100 channels per second (conventional mode)
Search Rate:
100 steps per second (Normal Search)
300 steps per second (Turbo Search)
Scan Delay
2 seconds
Audio Output
210 mW nominal into 8Ω internal speaker
39 mW nominal into 32Ω stereo headphone
8 mW nominal into 64Ω earphone
Power 4.8 VDC 800mAh (internal battery or
Requirements: AD70U AC Adapter
Antenna: Rubber Antenna (included)
External Jacks: External earphone, DC 12V power jack
Size:
Weight:
2½ in. (W) x 1¾ in. (D) x 6 in. (H)
11 oz.
Features, specifications, and availability of optional
accessories are all subject to change without notice.
78
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix
Preset Fleet Maps
Preset Map E1P1
Preset Map E1P2
Block
Size Code
Block
Size Code
0
1
2
3
4
5
6
7
S11
S11
S11
S11
S11
S11
S11
S11
0
1
2
3
4
5
6
7
S4
S4
S4
S4
S4
S4
S4
S4
Preset Map E1P3
Preset Map E1P4
Block
Size Code
Block
Size Code
0
1
2
3
4
5
6
7
S4
S4
S4
S4
S4
S4
S12
--
0
1
2
3
4
5
6
7
S12
--
S4
S4
S4
S4
S4
S4
Preset Map E1P5
Preset Map E1P6
Block
Size Code
Block
Size Code
0
1
2
3
4
5
6
7
S4
S4
S12
--
S4
S4
S4
S4
0
1
2
3
4
5
6
7
S3
S10
S4
S4
S12
--
S12
--
Preset Map E1P7
Preset Map E1P8
Block
Size Code
Block
Size Code
0
1
2
3
4
5
6
7
S10
S10
S11
S4
S4
S4
0
1
2
3
4
5
6
7
S1
S1
S2
S2
S3
S3
S4
S4
S4
S4
79
Download from Www.Somanuals.com. All Manuals Search And Download.
Preset Map E1P9
Preset Map E1P10
Block
Size Code
Block
Size Code
0
1
2
3
4
5
6
7
S4
S4
S0
S0
S0
S0
S0
S0
0
1
2
3
4
5
6
7
S0
S0
S0
S0
S0
S0
S4
S4
Preset Map E1P11
Preset Map E1P12
Block
Size Code
Block
Size Code
0
1
2
3
4
5
6
7
S4
S0
S0
S0
S0
S0
S0
S0
0
1
2
3
4
5
6
7
S0
S0
S0
S0
S0
S0
S0
S4
Preset Map E1P13
Preset Map E1P14
Block
Size Code
Block
Size Code
0
1
2
3
4
5
6
7
S3
S3
S11
S4
S4
S0
S0
S0
0
1
2
3
4
5
6
7
S4
S3
S10
S4
S4
S4
S12
--
Preset Map E1P15
Preset Map E1P16
Block
Size Code
Block
Size Code
0
1
2
3
4
5
6
7
S4
S4
S4
S11
S11
S0
S12
--
0
1
2
3
4
5
6
7
S3
S10
S10
S11
S0
S0
S12
--
80
Download from Www.Somanuals.com. All Manuals Search And Download.
User Defined Fleet Maps
Type I Programming Information
When a Type I system is designed, the address
information for all the IDs is divided into 8 equal sized
blocks, numbered 0–7. When you program your scanner to
track a Type I system, you must select a size code for each
of these blocks. When you have assigned a size code to all
8 blocks, you’ll have defined the Fleet Map for the system
you’re tracking. Each size code determines the number of
Fleets, Subfleets, and IDs each block will have. For
example, a size code of S-4 has one Fleet, which is divided
into 16 separate Subfleets, and it has a total of 512
individual IDs.
When a block is assigned a size code, the Fleet or Fleets
created within the block are assigned a Type I ID. The way
these IDs display on your scanner depend on the block
number and the block’s size code. When a Type I ID
displays, the leftmost digit represents the block which
contains the ID. The next two digits identify which Fleet is
active, and the last digit(s) identifies the Subfleet.
405-12
Block
(1 digit)
Subfleet
(1 or 2 digits)
Which Fleet
within the Block
(2 digits)
The details concerning how the size codes are selected by
a Type I System designer are highly dependent on the
specific needs of the system’s users. Some organizations
may want many subfleets with only a few radios each,
while another organization may want only a few subfleets
with many radios each. Your task is to program your fleet
map with the same size code assignments as the trunked
system. If you do this accurately, you’ll track all the
Fleet-Subfleet combinations used by the system. In other
words, you’ll hear complete communications while
monitoring a trunked system.
81
Download from Www.Somanuals.com. All Manuals Search And Download.
If you don’t already know the size codes used, you’ll have
to guess at them. But since you don’t have to figure out all
the blocks at once, this isn’t as hard as it seems. Select a
size code for a block, and then press
. Now listen to the
communications. If you decide you are receiving most of
the replies to the conversations with IDs assigned to the
block you just programmed, then you’ve probably selected
the right size code and can work on the next block of the
map.
Finally, for most public safety systems there are some size
codes which are more common. S-3 and S-4 are probably
the most common, followed by S-10, S-11, and S-12.
Fleet Map Size Codes
Size
Fleets
Subfleets
IDs
Blocks
Used
S–0
S–1
Reserves block for Type II IDs
+
1
1
1
1
1
1
1
1
1
1
1
2
4
8
128
16
8
4
8
16
64
S–2
S–3
8
128
512
32
S–4
1
16
4
S–5
64
32
32
16
8
S–6
8
32
S–7
4
64
S–8
4
128
256
256
256
1024
2048
4096
S–9
4
S–10
S–11
S–12
S–13
S–14
4
8
2
16
16
16
16
1
1
1
82
Download from Www.Somanuals.com. All Manuals Search And Download.
Size Code Restrictions
If you select size code S-12, S-13, or S-14, there are some
restrictions as to which blocks can be used for these codes.
S-12 can only be assigned to Blocks 0, 2, 4, or 6.
S-13 can only be assigned to Blocks 0 and 4.
S-14 can only be assigned to Block 0.
Since these size codes require multiple blocks, you will be
prompted for the next available block when programming a
Fleet Map. For example, if you assign Block 0 as an S-12,
you will be prompted for b2, the next block available, instead
of b1. And if you assign Block 0 as an S-14, you would not
see another prompt because it uses all available blocks.
83
Download from Www.Somanuals.com. All Manuals Search And Download.
An EDACS Trunked System
84
Download from Www.Somanuals.com. All Manuals Search And Download.
One Year Limited Warranty
Important:Evidence of original purchase is required for warranty
service.
WARRANTOR: UNIDEN AMERICA CORPORATION (Uniden)
ELEMENTS OF WARRANTY: Uniden warrants, for one year, to
the original retail owner, this Uniden product to be free from
defects in materials and craftsmanship with only the limitations or
exclusions set out below.
WARRANTY DURATION: This warranty to the original user shall
terminate and be of no further effect 12 months after the date of
original retail sale. The warranty is invalid if the Product is (A)
damaged or not maintained as reasonable or necessary, (B)
modified, altered, or used as part of any conversion kits,
subassemblies, or any configurations not sold by Uniden, (C)
improperly installed, (D) serviced or repaired by someone other
than an authorized Uniden service center for a defect or
malfunction covered by this warranty, (E) used in any conjunction
with equipment or parts or as part of any system not
manufactured by Uniden, or (F) installed or programmed by
anyone other than as detailed by the owners manual for this
product.
STATEMENT OF REMEDY: In the event that the product does
not conform to this warranty at any time while this warranty is in
effect, warrantor will either, at its option, repair or replace the
defective unit and return it to you without charge for parts,
service, or any other cost (except shipping and handling) incurred
by warrantor or its representatives in connection with the
performance of this warranty. Warrantor, at its option, may
replace the unit with a new or refurbished unit. THE LIMITED
WARRANTY SET FORTH ABOVE IS THE SOLE AND ENTIRE
WARRANTY PERTAINING TO THE PRODUCT AND IS IN LIEU
OF AND EXCLUDES ALL OTHER WARRANTIES OF ANY
NATURE WHATSOEVER, WHETHER EXPRESS, IMPLIED OR
ARISING BY OPERATION OF LAW, INCLUDING, BUT NOT
LIMITED TO ANY IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE. THIS WARRANTY DOES NOT COVER OR
PROVIDE FOR THE REIMBURSEMENT OR PAYMENT OF
INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states
do not allow this exclusion or limitation of incidental or
consequential damages so the above limitation or exclusion may
not apply to you.
LEGAL REMEDIES: This warranty gives you specific legal rights,
and you may also have other rights which vary from state to state.
This warranty is void outside the United States of America.
PROCEDURE FOR OBTAINING PERFORMANCE OF
WARRANTY: If, after following the instructions in the owners
manual you are certain that the product is defective, pack the
Product carefully (preferably in its original packaging). The
product should include all parts and accessories originally
packaged with the Product. Include evidence of original purchase
and a note describing the defect that has caused you to return it.
The Product should be shipped freight prepaid, by traceable
means, to warrantor at:
UNIDEN AMERICA CORPORATION
4700 Amon Carter Boulevard
Fort Worth, TX 76155
(800) 297-1023, 8a.m. To 5p.m. Central, Monday through Friday
Download from Www.Somanuals.com. All Manuals Search And Download.
©1999 Uniden America Corporation.
All rights reserved. UBZZ01301ZZ
Printed in the Philippines
Download from Www.Somanuals.com. All Manuals Search And Download.
300-Channel Trunk Tracking Scanner
. c o m
e b s i t e . t a r u t n k t r a c k e r
W
V i s i t o u r
w w w
Download from Www.Somanuals.com. All Manuals Search And Download.
Top View and Display
20
21 22 23
20. Antenna Connector
21. Earphone Jack
22. Squelch Control
23. On/Off Volume Control
24
25
26
27
28
1
2
3
4
5
6
7
8
9
10
BANK
TRUNK
32
33
31
ATT
BATT
888 888.8888
DATA POLICE
SCAN SEARCH PRI HOLD DLY L/O
E RR
AIR MRN WX
30
29
24. Channel Display
25. Frequency Display
26. Bank/Activity Indicators
27. Attenuate Indicator
28. Battery Low Indicator
29. Keypad Lockout Indicator
30. Mode Indicators
31. Priority Channel Indicator
32. Bank/Trunk Indicators
33. Trunk System Indicators
Download from Www.Somanuals.com. All Manuals Search And Download.
Precautions
Ω
Ω
®
®
Uniden and Bearcat are registered trademarks of Uniden
America Corporation.
Download from Www.Somanuals.com. All Manuals Search And Download.
Front View
11
BANK
TRUNK
1
2
3
4
5
6
7
8
9
10
1
ATT
BATT
12
888888.8888
DATA POLICE FIRE RR
AIR MRN WX
SCAN SEARCH PRI HOLD DLY L/O
13
2
3
14
4
5
6
7
8
9
15
16
17
18
19
10
1. DC Power Jack
2. Scan Key
10.Light
11.Speaker
12.Display
3. Manual Key
4. Trunking Key
5. Decimal Key
6. Service Key
13.Remote jack
14.Keypad
15.Enter Key
7. Limit Key/Down Key
16.Search Key
17.Hold Key/Up Key
8. Priority Key/Turbo Key
18.Lockout Key
19.Data Key
9. Delay Key
/ Lock Key
Download from Www.Somanuals.com. All Manuals Search And Download.
|