				SPECIFICATIONS   
					Electrical Ratings   
					Power Ratings   
					Note: The V-Flex is a universal input circuit capable of operation at 120 Vac or 240 Vac and 50Hz   
					or 60Hz.   
					The unit is designed to be hardwired to an appropriate electrical service in accordance with NEC.   
					Temperature Ratings   
					Ambient Temperature Range: 40°F to 135°F (4°C to 51°C)   
					Lamp Temperature Range: 40°F to 135°F (4°C to 51°C)   
					Relative Humidity: Up to 95% rh, non-condensing   
					Power Consumption   
					Model   
					Input Current Lamp Wattage   
					(A)   
					(W)   
					120V   
					240V   
					0.6   
					60   
					0.3   
					60   
					Approvals   
					Underwriters Laboratories: File no. E212213. Category Code ABQK (Accessories, Air Duct   
					Mounted) UL Standards: UL153, UL1598 & UL1995. The health aspects associated with the use   
					of this product and its ability to aid in disinfection of environmental air have not been investigated   
					by UL. This product is classified only when installed with accompanying part numbers 19-1020,   
					19-1030, 19-3004 and 19- 3005.   
					TM   
					Figure 1. V-Flex Lamp Module   
					19-2021 Rev E, 06/05/07   
					3 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				APPLICATION   
					When installed in forced air heating and cooling systems, the V-Flex kills airborne and surface   
					microorganism contaminants. It is designed to be mounted in-duct for airborne, “on-the-fly”   
					applications as well as surface irradiation applications. The design allows for many different   
					levels of UV dosage. Proper dosage is affected by many factors, such as air temperature,   
					velocity, and duct reflectivity. The space between supports (typically 32”) and the space between   
					rows (typically 24” for surfaces and 12” to 18” for moving air streams) can be increased or   
					reduced to adjust for dosage.   
					See your Altru-V dealer or sales representative for assistance, as required.   
					INSTALLATION   
					1. Read these instructions carefully. Failure to follow the instructions could damage the   
					product or cause a hazardous condition.   
					2. Check the electrical rating given in the instructions and on the product to make sure the   
					product is suitable for your application.   
					3. To avoid accidental exposure to ultraviolet light, the power supply to this product   
					must be electrically interlocked. Interlock switches must be installed at any   
					access panel or door within view of the UV fixtures.   
					4. The installer must be a trained, experienced service technician.   
					5. After installation is complete, check out product operation as provided in this guide.   
					6. If the HVAC system has been in use prior to installation, it is recommended that debris   
					and buildup on coils and HVAC system surfaces be cleaned.   
					Product Registration   
					Thank you for purchasing this product from UVDI! Prior to any other installation activities,   
					
					returning the enclosed self-addressed postcard. Product registration will insure that your   
					warranty is handled in a proper and expeditious manner. In addition, it will allow UVDI to   
					provide you with important updates regarding your new product including reminders of   
					when replacement parts are needed and also make you eligible for future parts discounts   
					CAUTION   
					Personal Injury Hazard   
					Power supply can cause electrical shock.   
					Disconnect power supply before beginning installation. Do not open lamp knob. There are no   
					user serviceable components inside. Professional installation is required per NEC standards.   
					WARNING   
					UV Light Hazard   
					Harmful to bare skin and eyes.   
					Can cause temporary or permanent loss of vision.   
					19-2021 Rev E, 06/05/07   
					4 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Never look at the lamps while illuminated. Only view illumination by way of view port accessory.   
					To prevent exposure to ultraviolet light, disconnect power to the V-Flex before servicing any part   
					of the HVAC system.   
					MOUNTING LOCATION   
					CAUTION   
					Equipment Damage Hazard   
					Ultraviolet light can cause color shift or structural degradation of plastic   
					HVAC materials.   
					Select mounting location that prevents exposure to plastic components with unknown resistance   
					to ultraviolet light. It is recommended that there be a minimum of three-feet between ultraviolet   
					lamps and plastic-fabricated devices (such as non-fiberglass media filters).   
					CAUTION   
					Equipment Damage Hazard   
					Ultraviolet light can cause color shift or surface degradation and   
					sometimes structural degradation of non-metallic components.   
					Select a mounting location that prevents exposure to plastic flexible duct components,   
					polyurethane foam insulation material, rubber hoses, wire insulation, etc. If mounting options are   
					limited, items above should be protected with ultraviolet resistant material such as aluminum foil,   
					aluminum duct tape, or metallic shields or equivalent.   
					1. Inspect and determine an appropriate location inside the air handling system for the   
					installation. The location should allow for the mounting of a bracket on the floor and the   
					ceiling of the air handler and should be readily accessible for the cleaning of lamps and   
					the annual replacement of lamps (see Figure 2a).   
					Record Dimensions:   
					Dimension A Dimension B Dimension C   
					Figure 2a   
					19-2021 Rev E, 06/05/07   
					5 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				2. Determine the number and configuration of Lamp Modules and Power Junction Modules.   
					Note: the maximum number of Lamp Modules (19-1000) to be installed per Power   
					Junction Module (19-1020) is 24.   
					3. Mark the location of the lower mounting bracket on the lower mounting surface of the   
					installation area.   
					4. Measure overall length/height required for the installation (Figure 2a, dimension ‘A’).   
					This dimension is the distance from the lower mounting surface to the upper   
					mounting surface of the mounting location. Record the measurement in the table in   
					Figure 2a. for Dimension A.   
					5. Referencing Dimension A, deduct ½” from the overall distance from the lower to   
					upper mounting surface and record as Dimension B. This is the overall length of the   
					Main Support.   
					6. Install the lower bracket to the lower mounting surface of the installation area in the   
					previously marked location. Four sheet metal screws (provided) should be used to   
					securely fasten the lower bracket to the lower mounting surface (see Figure 2a).   
					7. Place the Main Support on a horizontal surface in an appropriate work area.   
					Measure and mark off the Dimension B onto the Main Support (see Figure 2b).   
					Then make one cut through the cross-section of the Main Support using a tool   
					appropriate for cutting aluminum. Cut only from one end, as it is important to retain a   
					wiring feed-through hole in the Main Support section to be installed.   
					Figure 2b   
					INSTALLATION OF THE LAMP MODULES   
					1. Carry the Main Support into the installation area. Place the upper mounting bracket   
					onto the top end of the Main Support. Do not install screws in the upper   
					mounting bracket at this time.   
					2. Place the lower end of the Main Support into the lower mounting bracket, which is   
					secured to the lower mounting surface.   
					3. Swing the Main Support into place so that it is vertical.   
					4. When vertical, use the supplied hardware to anchor the upper mounting bracket into   
					the duct ceiling.   
					5. First mark the location where the Power Junction Module is to be attached. It is   
					important to mount the Power Junction Module near, but not covering, the wire feed   
					through hole in the Main Support. It is recommended that the Power Junction   
					Module be attached to the upper end of the Main Support.   
					6. Mark the Main Support locations where the Lamp Modules should be attached.   
					Note: the maximum number of Lamp Modules (19-1000) to be installed per   
					Power Junction Module (19-1020) is 24.   
					7. Once the desired locations for the Lamp Modules and Power Junction Modules have   
					been identified, disassemble the upper mounting bracket from the upper mounting   
					surface and return the Main Support to the work area.   
					19-2021 Rev E, 06/05/07   
					6 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				8. Select one side of the Main Support to start assembly of lamp modules. Begin   
					assembly of the Lamp Modules attachments first (see Figure 3b). Begin by installing   
					the Lamp Module furthest from the Power Junction Module location.   
					9. Thread the three wires from the last Lamp Module installed to the main extrusion   
					through the strain relief and into the wiring compartment of the next Lamp Module.   
					10. Route the external wires from the Lamp Modules into the Main Support wire raceway.   
					Attach Lamp Modules to the Main Support with supplied screws (4) as shown (See   
					Figure 3b).   
					Figure 3a   
					Figure 3b   
					11. Prepare next Lamp Module for attachment by removing wire access cover and   
					loosening strain-relief screws.   
					12. Thread the three wires from the last Lamp Module installed to the Main Support   
					through the strain relief and into the wiring compartment of the next Lamp Module.   
					13. Route the external wires from the Lamp Module under installation into the Main   
					Support wire raceway and attach next Lamp Module to support with four screws.   
					14. Tighten strain-relief screws to secure the external power wires   
					15. Cut, as required, and strip 3/8" from the wires and insert into respective WAGO   
					connector terminals (black-black, white-white, green-green)   
					16. Fold cables into Lamp Module enclosure and attach the wire access cover.   
					17. Repeat steps 5–14 as required until all Lamp Modules to be installed on the present   
					side of the Main Support are installed.   
					18. Proceed to install Lamp Modules to the second Lamp Module mounting side of the Main   
					Support.   
					19. Begin by installing the Lamp Module furthest from Power Junction Module. Repeat the   
					instructions included in steps 5 through 14.   
					19-2021 Rev E, 06/05/07   
					7 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				20. After installation of the last Lamp Module on the side opposite of the Power Junction   
					Module, route the power wires from the last Lamp Module installed through the feed   
					through hole connecting the wire raceway from either side. Do not install lamps at this   
					stage. (see Figure 3c for example of completely wired system)   
					Figure 3c   
					INSTALLATION OF THE POWER JUNCTION MODULE   
					Figure 4a   
					21. Remove Power Junction Module cover.   
					22. Thread wires from last Lamp Module installed on each side through Power Junction   
					Module strain relief (See Figure 4a).   
					23. Attach Power Junction Module to support with screws provided (2) as shown in   
					Figure 4a.   
					24. Pull wires through strain relief until slack is removed and tighten strain relief screws   
					to secure the wires entering the Power Junction Module   
					25. Cut and strip wires, 3/8", and insert into respective WAGO connector terminals   
					(black-black, white-white, green-green), as required.   
					26. Fold cables into Power Junction Module enclosure.   
					PREPARATION OF THE WIRE/RACEWAY COVER   
					Raceway   
					19-2021 Rev E, 06/05/07   
					8 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				IMPORTANT   
					It is a requirement to incorporate the wire raceway covering to all exposed portions of   
					the wire raceway on the mounting sides of the Main Support where modules have been   
					mounted.   
					27. Identify, measure and record all spaces on the Main Support between Lamp Modules   
					and the Power Junction Module (see Figure 2b).   
					28. Place the bare wire/raceway cover onto a horizontal surface in an appropriate work   
					area. Mark off the dimensions corresponding to the gap dimensions recorded in step   
					7 onto the raceway cover sections. Make one cut through the cross-section of the   
					raceway cover for each space identified using a tool appropriate for cutting   
					aluminum.   
					29. Install (press fit) the raceway covers onto the Main Support for all gaps existing in the   
					Main Support raceway.   
					INSTALLATION OF MAIN SUPPORT INTO AIR HANDLING DUCT   
					1. Carefully carry the partially assembled Main Support into the installation area.   
					With bottom mounting bracket   
					screwed to extrusion and top   
					mounting bracket loose on extrusion   
					set bottom down on mounting surface   
					and swing up into position.   
					Figure 6a   
					2. Place the second mounting bracket onto the top end of the Main Support. Do not   
					install screws into the top end bracket at this stage.   
					3. Place the lower end of the Main Support into the lower mounting bracket, which is   
					secured to the lower mounting surface.   
					4. Swing the Main Support into place so that it is vertical.   
					5. When vertical, use the supplied hardware to anchor the upper mounting bracket into   
					the duct ceiling.   
					6. Anchor the Main Support to the lower mounting bracket using two screws.   
					7. Anchor the Main Support to the upper mounting bracket using two screws.   
					19-2021 Rev E, 06/05/07   
					9 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ELECTRICAL CONNECTION OF THE SYSTEM   
					WARNING   
					Personal Serious Injury Hazard   
					Power supply can cause severe electrical shock.   
					Disconnect power supply before installation. All wiring should be in accordance with NEC.   
					1. Bring power to the Power Junction Module and use appropriate knock-out on the   
					Power Junction Module.   
					2. Install power conduit connector.   
					3. Using supplied WAGO connector terminals, connect assembly wires to power supply.   
					(Line in to black, neutral to white, and earth ground to green).   
					4. Attach the Power Junction Module cover with two nuts.   
					WARNING   
					UV Light Hazard   
					Harmful to bare skin and eyes.   
					Can cause temporary or permanent loss of vision.   
					Never look at the lamps while illuminated. Only view illumination by way of view port accessory.   
					To prevent exposure to ultraviolet light, disconnect power to the V-FlexTM before servicing any   
					part of the HVAC system.   
					WARNING   
					The electrical supply circuit connected to this UV appliance must be routed through an electrical   
					interlock switch placed on the HVAC system duct access panels and doors to prevent accidental   
					UV exposure when servicing the air ducts or equipment.   
					LAMP INSTALLATION   
					CAUTION   
					Breakable Glass Hazard   
					Can cause personal injury.   
					Be careful when inserting lamp into lamp base. Wear protective gloves when handling lamp.   
					1. To install lamps into Lamp Modules. Slide lamp and black clip into the lamp module   
					as shown in the below picture:   
					19-2021 Rev E, 06/05/07   
					10   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				19-2021 Rev E, 06/05/07   
					11   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				2. Insert the black V-Flex Clip into the module so that is holding the lamp in place and   
					the clip is secured onto the metal module. Make sure the clip is slid over the lamp   
					module as shown below:   
					3. Push the lamp in till it snaps into place. Verify that lamp is retained.   
					4. Lamp should not have any slack to move.   
					19-2021 Rev E, 06/05/07   
					12   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				WARNING   
					UV Light Hazard   
					Harmful to bare skin and eyes.   
					Can cause temporary or permanent loss of vision.   
					Never look at the lamps while illuminated. Only view illumination by way of view port accessory.   
					To prevent exposure to ultraviolet light, disconnect power to the V-Flex before servicing any part   
					of the HVAC system.   
					WARNING   
					Prevent accidental exposure to service personnel.   
					Install interlock switches on all access doors and affix UV warning labels to   
					HVAC equipment.   
					5. Reconnect the power to the HVAC system.   
					6. Choose a location on the adjacent HVAC equipment for the HVACmaintenance label   
					included in the V-Flex Lamp Module packing box. Choose a location that a future   
					installer can easily see during all future HVAC maintenance or repair.   
					7. Adhere the HVAC maintenance label to the HVAC equipment access door or panel.   
					CHECKOUT   
					The installer should verify that the ultraviolet lamps are operating only by viewing through view   
					port accessory. Do not attempt to look directly into the duct to see the illuminated ultraviolet   
					lamp. The installer should orient the owner to the unit by demonstrating use of the view port   
					accessory and discussing how to determine when the unit is functioning properly without looking   
					directly into the duct to see the illuminated ultraviolet lamp. The installer should also emphasize   
					the hot surface and electrical shock safety warnings. The installer should leave the product data   
					with the owner and review the lamp cleaning and lamp replacement procedures.   
					OPERATION   
					TROUBLESHOOTING AND SERVICE   
					The V-Flex has no field-serviceable parts. Lamp cleaning is recommended as routine   
					maintenance four times a year, or every three months (quarterly). Annual lamp replacement   
					is required. See the Replacing the Lamp (Annually) section for detailed procedural   
					information.   
					MERCURY NOTICE   
					This device contains mercury in the sealed ultraviolet lamp. Do not place your used lamp in the   
					trash. Dispose of properly.   
					Broken Lamp Clean-up   
					Do not use a household vacuum. Sweep debris into a plastic bag and dispose of properly.   
					Contact your local waste management authority for instructions regarding recycling and the   
					proper disposal of old lamp.   
					19-2021 Rev E, 06/05/07   
					13   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				CAUTION   
					UV Lamp Burn Hazard   
					Harmful to bare skin. Can cause severe burns.   
					Disconnect power 15 minutes before removing the ultraviolet lamp.   
					WARNING   
					UV Light Hazard   
					Harmful to bare skin and eyes.   
					Can cause temporary or permanent loss of vision.   
					Never look at the lamps while illuminated. Only view illumination by way of view port accessory.   
					WARNING   
					UV Light Hazard.   
					Harmful to skin and eyes.   
					Can cause temporary or permanent loss of vision.   
					Never look at the lamp while illuminated.   
					Cleaning the Lamps   
					Use alcohol or glass cleaner. Do not touch.   
					Depending upon operating conditions, lamp cleaning is recommended as routine maintenance up   
					to four times a year, when necessary. If the air stream is filtered, cleaning schedule may be   
					reduced.   
					To clean the lamp:   
					1. Disconnect power to HVAC system. Never enter system with UV lamps illuminated.   
					2. Open the system access panel or door.   
					3. Allow the lamp to cool for at least 15 minutes.   
					4. Wipe the lamp glass using a soft cloth with window cleaner applied to the cloth. Do not   
					touch the lamp surface with your hands; use only the cloth.   
					5. Wipe the lamp with a clean, dry cloth as a dirty cloth can cause the lamps to soil more   
					quickly.   
					6. Reconnect the power to your HVAC system.   
					7. Replace and lock enclosure cover.   
					8. Verify that the ultraviolet lamp is operating only by viewing through the view port   
					accessory. Never look directly at the lamp while illuminated.   
					Replacing the Lamp (Annually)   
					Annual replacement of the lamp is required. To replace the lamp:   
					1. Disconnect the power to the HVAC system.   
					2. Open the access door or panel.   
					19-2021 Rev E, 06/05/07   
					14   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				3. Allow the lamp to cool for at least 15 minutes.   
					4. Depress lamp release button and remove lamp. Be careful not to strike or hit the lamp   
					glass with the enclosure edges.   
					5. Insert new lamp into the Lamp Module. Depress lamp release button and insert lamp.   
					Let go of the lamp release button and verify that lamp is retained.   
					6. Reconnect the power to the HVAC system.   
					7. Clean the lamp (see Cleaning the Lamps) to remove any fingerprints or dirt on the glass.   
					This device contains mercury in the sealed ultraviolet bulb(s). Do not place your   
					used bulb(s) in the trash. Dispose of properly.   
					19-2021 Rev E, 06/05/07   
					15   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				EQUIPMENT WARRANTY   
					UltraViolet Devices, Inc. (UVDI), warrants to original Buyer for one year from the date of   
					original installation, or eighteen (18) months from date of shipment, whichever comes first, that its   
					goods are free from defect in material and workmanship under normal use and service. UVDI’s   
					obligation under this warranty shall be limited to the repair or replacement of those goods which   
					prove defective, provided that such products are installed, maintained, and operated for the   
					purpose and in the manner intended and for which UVDI instructs or recommends. Neither UVDI   
					nor its dealers shall be liable for any special or consequential damages directly or indirectly   
					arising from the design, construction, installation, servicing, or operation of the goods. THIS IS   
					UVDI’S SOLE WARRANTY. NEITHER UVDI NOR ITS DEALERS MAKE ANY OTHER   
					WARRANTY OF ANY KIND, EXPRESSED OR IMPLIED. ALL IMPLIED WARRANTIES OF   
					MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED UVDI’S   
					AFFORESTATED OBLIGATIONS ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS   
					WARRANTY.   
					UVDI AND ITS DEALERS’ LIABILITY UNDER THIS WARRANTY SHALL IN NO EVENT   
					EXCEED THE COST OF THE GOODS SOLD UNDER THIS CONTRACT OF SALE. UVDI   
					neither assumes, nor authorizes any person to assume for it, any obligation in connection with the   
					goods. This warranty shall not apply to any goods (a) which have been subjected to misuse,   
					tampering, negligence, or accidents; or (b) the serial numbers of which have been altered,   
					defaced, or removed; or (c) which have been used in a manner contrary to UVDI’s instructions or   
					recommendations. Buyer shall not return to UVDI any allegedly defective goods without UVDI’s   
					prior written authorization. This warranty may not be assigned or transferred.   
					Product Registration   
					
					return the enclosed self-addressed postcard to UVDI. Product registration will insure that your   
					warranty is handled in a proper and expeditious manner. In addition, it will allow UVDI to provide   
					you with important updates regarding your new product including reminders of when replacement   
					parts are needed and also make you eligible for future parts discounts.   
					Manufactured by:   
					26145 Technology Drive   
					Valencia, CA 91355   
					(877) PUREUVC   
					(661) 257-4698 fax   
					
					Specifications subject to change without notice.   
					©Altru-V and V-Flex are brands owned by UVDI.   
					Copyright © 2003 by UltraViolet Devices, Inc. All rights reserved.   
					19-2021 Rev E, 06/05/07   