U Line Ice Maker BI95 User Manual

Use a n d Ca re Gu id e  
Ice Ma ke r Mo d e ls:  
BI95, BI98, SP18  
BI95  
BI98  
SP18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 Table of Contents  
Introduction ...............................................................................................................................2  
Warranty Registration .......................................................................................................2  
Please Record Your Model Information ...........................................................................2  
Table of Contents .......................................................................................................................3  
Safety Precautions ......................................................................................................................5  
Safety Alert Definitions .....................................................................................................5  
General Precautions ...........................................................................................................5  
Product Features ........................................................................................................................6  
Origins Ice Maker Models BI95, BI98, SP18 .......................................................................6  
Operation ...................................................................................................................................6  
Initial Startup .....................................................................................................................6  
Ice Harvest Control .............................................................................................................7  
Ice Maker ............................................................................................................................7  
Normal Operating Sounds .................................................................................................8  
Outdoor, Marine and RV Usage ........................................................................................8  
Storage, Vacation, Moving ................................................................................................8  
Product Disposal .................................................................................................................9  
Cleaning and Maintenance .......................................................................................................9  
General Cleaning ...............................................................................................................9  
Maintenance ....................................................................................................................10  
Service .......................................................................................................................................14  
Before Calling for Service ................................................................................................14  
If Service is Required ........................................................................................................14  
Replacement Parts ...........................................................................................................14  
Troubleshooting Guide ....................................................................................................15  
U-Line Corporation Limited Warranty ....................................................................................19  
BI95, BI98, SP18  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
This page intentionally left blank  
4
BI95, BI98, SP18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING  
3 Safety Precautions  
SHOCK HAZARD - Electrical Grounding Required.  
• Never attempt to repair or perform  
maintenance on the unit until the electricity  
has been disconnected.  
• Never remove the round grounding prong from  
the plug and never use a two-prong grounding  
adapter.  
• Altering, cutting of power cord, removal of  
power cord, removal of power plug, or direct  
wiring can cause serious injury, fire and/or loss  
of property and/or life, and will void the  
warranty.  
IMPORTANT  
PLEASE READ all instructions completely before  
attempting to install, operate, or service your unit.  
• Proper installation procedures must be followed  
if this unit is being initially installed, or is moved  
to a new location after being in service. An  
INSTALLATION GUIDE for your unit, providing  
complete installation information is available  
from U-Line Corporation directly, and must be  
consulted before any installation is begun. U-Line  
contact information appears on the rear cover of  
this guide.  
• Never use an extension cord to connect power  
to the unit.  
• Always keep your working area dry.  
• This unit requires connection to a grounded  
(three-prong), polarized receptacle that has been  
placed by a qualified electrician in accordance  
with applicable electrical codes.  
CAUTION  
• Use care when moving and handling the unit. Use  
gloves to prevent personal injury from sharp  
edges.  
• If your model requires defrosting, DO NOT use any  
type of heater to defrost. Using a heater to speed  
up defrosting can cause personal injury and  
damage to the inner lining.  
Safety Alert Definitions  
Safety items throughout this guide are labeled with a  
Danger, Warning or Caution based on the risk type:  
DANGER  
Danger means that failure to follow this safety  
statement will result in severe personal injury or  
death.  
IMPORTANT  
• Do not lift unit by door handle.  
• Never install or operate the unit behind closed  
doors. Be sure front grille is free of obstruction.  
Obstructing free air flow can cause the unit to  
malfunction and may void the warranty.  
• Failure to clean the condenser every three months  
can cause the unit to malfunction. This could void  
the warranty.  
WARNING  
Warning means that failure to follow this safety  
statement could result in serious personal injury  
or death.  
CAUTION  
• Allow unit temperature to stabilize for 24 hours  
before use.  
Caution means that failure to follow this safety  
statement may result in minor or moderate  
personal injury, property or equipment damage.  
• If your model requires defrosting, never use an  
ice pick or other sharp instrument to help speed  
up defrosting. These instruments can puncture  
the inner lining or damage the cooling unit.  
• Use only genuine U-Line replacement parts.  
Imitation parts can damage the unit, affect its  
operation or performance and may void the  
warranty.  
General Precautions  
Use this appliance for its intended purpose only and  
follow these general precautions along with those listed  
throughout this guide:  
DANGER  
RISK OF CHILD ENTRAPMENT. Before you throw away  
your old refrigerator or freezer, take off the doors  
and leave shelves in place so that children may not  
easily climb inside.  
BI95, BI98, SP18  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 Product Features  
5 Operation  
Origins Ice Maker  
Models BI95, BI98, SP18  
1
2
All Origins Ice Makers provide high daily ice production  
and storage capabilities, and conserve on water, using  
only 2-3/4 gallons (10.4 L) to produce approximately 22 lbs  
(10 kg) of ice.  
• Model 95 produces up to 23 lbs (10.4 kg) of ice per day  
and will store 12 lbs (5.4 kg).  
• Model 98 produces up to 25 lbs (11.3 kg) of ice per day  
and will store 25 lbs (11.3 kg).  
ULIN_0027_A  
• Model SP18 produces up to 20 lbs (9 kg) of ice per day  
and stores 12 lbs (5.4 kg).  
Figure 2  
IMPORTANT  
Additional Origins Features  
• All models feature a clear, removable ice bucket.  
Proper air flow (Figure 2 - Model 95 and 98 shown)  
is required for your unit to operate at its highest  
efficiently. A grille, located in the base of the unit,  
must not be blocked at any time, or your unit will  
not perform as expected.  
• Occasional manual defrosting will be required.  
• Models 95 and 98 doors feature an integrated handle,  
and will accommodate a custom flat or raised panel to  
match surrounding cabinets.  
• The Model SP18 door features stainless steel hinges  
and fasteners to prevent corrosion, is field-reversible,  
and includes a travel pin to keep the door securely  
closed.  
Initial Startup  
All U-Line units are shipped with controls that are preset.  
No initial adjustments are required.  
• All models feature black or white vinyl clad steel  
cabinets that provide a rich textured look, and resist  
scratching, peeling, and flaking.  
IMPORTANT  
It is possible that dirt or scale will dislodge in the  
water line. Always throw away all ice cubes made  
during the first two to three hours of operation.  
Features and specifications are subject to change without  
notice.  
Model 95 and 98  
The power switch is located behind the front grille. A  
small opening in the top of the grille (Figure 2, 2) is  
provided to access the switch.  
ULIN_0129_A  
Figure 3  
Depress the ON/OFF switch (Figure 3) as required to turn  
the unit on or off.  
6
BI95, BI98, SP18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model SP18  
Ice Maker  
To turn the unit on or off, press the rocker switch (Figure  
3) located in the center of the lower grille.  
When the ice bucket is full, the ice making mechanism will  
shut off. However, the refrigeration system will continue  
to cool and maintain the cube supply.  
Ice Harvest Control  
IMPORTANT  
Adjustments are not normally needed. The control is  
preset at the factory.  
Do not place cans or bottles in the ice compartment  
because they will freeze.  
IMPORTANT  
Making adjustments may affect the daily ice  
production of the unit.  
1
2
ULIN_0087_A  
Figure 6  
ULIN_0027_A  
Ice production may be interrupted by raising the bin arm  
into an upright and locked position (Figure 6). The unit  
will maintain temperature for ice storage.  
Figure 4  
Models 95 and 98  
IMPORTANT  
To adjust the Ice Harvest Control:  
If you are not intending to use the ice maker and  
turn the supply valve off, it is imperative to raise  
the bin arm of the ice maker (Figure 6). Failure to  
raise the bin arm may result in damage to the water  
valve.  
1. Remove the front grille (one screw) (Figure 4, 1).  
Certain sounds are normal during the unit’s operation.  
You may hear the compressor or fan motor, the water  
valve, or ice dropping into the ice bucket.  
WARNING  
ULIN_0131_A  
NEVER use an ice pick, knife or other sharp  
instrument to separate cubes. Shake the ice  
bucket instead.  
Figure 5  
2. Turn the adjusting screw (Figure 5) using a flat tip  
screwdriver in a small increment clockwise for a COLDER  
setting (slower ice production) or counterclockwise for  
a WARMER setting (faster ice production).  
During periods of limited usage or high ambient  
temperatures, it is common for cubes to fuse together.  
Shake the bucket to break apart cubes. If the ice maker is  
not used regularly, the ice bucket should be emptied  
periodically to ensure fresh cubes.  
3. Replace the front grille (one screw).  
Model SP18  
It is normal for cubes to appear cloudy. This is caused by  
air being trapped in the water due to fast freezing. It has  
nothing to do with the health, taste or chemical make-up  
of the water. It is the same air that is in every glass of  
water you drink.  
Model SP18 has a factory preset Ice Harvest Control that is  
optimized for ice production, and is not adjustable.  
The ice bucket can be removed for emptying and  
cleaning. To remove the ice bucket, raise the bin arm and  
remove the bucket from the ice compartment. Use the ice  
bucket for ice storage only.  
BI95, BI98, SP18  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Normal Operating Sounds  
Storage, Vacation, Moving  
All models incorporate rigid foam insulated cabinets to  
provide high thermal efficiency and maximum sound  
reduction for its internal working components. In spite of  
this technology, your model may make sounds that are  
unfamiliar.  
If the unit will not be used for an extended period, or  
otherwise stored, follow these steps completely:  
WARNING  
Electrical Shock Hazard. Disconnect power before  
servicing. Before operating, replace all panels.  
Failure to do so may result in death or electrical  
shock.  
Normal operating sounds may be more noticeable  
because of the unit’s environment. Hard surfaces such as  
cabinets, wood/vinyl/tiled floors and paneled walls have a  
tendency to reflect normal appliance operating noises.  
1. Remove all consumable contents from the unit.  
2. Disconnect power to the unit.  
Common refrigeration components, and a brief  
description of the normal operating sounds they make,  
are listed below. NOTE: Your product may not contain all  
of the components listed.  
3. Shut off water supply to the unit at the main water  
source.  
Compressor: The compressor makes a hum or pulsing  
sound that may be heard when it operates.  
IMPORTANT  
Evaporator: Refrigerant flowing through an evaporator  
may sound like boiling liquid.  
• If the ambient temperature is expected to drop  
below 45°F, turn off and unplug unit, and drain all  
water from the unit to prevent freezing damage  
not covered by the warranty.  
• The use of anti-freeze or other products of this  
nature is not necessary and is not recommended.  
Condenser Fan: Air moving through a condenser may be  
heard.  
Automatic Defrost/Drain Pan: Water may be heard  
dripping or running into the drain pan when the unit is in  
the defrost cycle.  
4. Disconnect the water valve inlet and outlet lines, and  
allow them to drain completely.  
Ice dropping into ice bucket.  
5. Reconnect power to the unit, and allow it to run for  
one hour (minimum) until any remaining ice has been  
ejected from the ice maker assembly.  
Outdoor, Marine and RV Usage  
Some U-Line models are designed to operate in outdoor,  
marine and RV environments. For best performance, keep  
the unit out of direct sunlight.  
6. Disconnect power to the unit, dry any remaining water  
from the ice maker assembly, and reconnect any lines  
removed from the water supply valve.  
• If the unit will be shut off for five days or more, prop  
door open to allow for air circulation and prevent mold  
and mildew.  
7. Disconnect the power cord from its outlet, and leave it  
disconnected until the unit is returned to service.  
8. Clean and dry the interior of the cabinet (See CLEANING  
AND MAINTENANCE: GENERAL CLEANING).  
IMPORTANT  
If the ambient temperature is expected to drop  
below 45°F, turn off and unplug unit, and drain all  
water from the unit to prevent freezing damage not  
covered by the warranty.  
9. During periods of non-use, the cabinet must remain  
open to prevent the formation of mold and mildew.  
Open door a minimum of 2" (5 cm) to provide the  
necessary ventilation.  
• High ambient temperatures (110°F or higher) may  
reduce ice production.  
8
BI95, BI98, SP18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product Disposal  
6 Cleaning and Maintenance  
General Cleaning  
If the unit is being removed from service for disposal,  
check and obey all Federal, State and/or Local regulations  
regarding the disposal and recycling of refrigeration  
appliances, and follow these steps completely:  
Exterior Cleaning (As Required)  
1. Disconnect power to the unit and unplug the power  
cord from its outlet.  
Black and White Models:  
• Surfaces may be cleaned with a mild detergent and  
warm water solution. Do not use solvent-based or  
abrasive cleaners. Use a soft sponge and rinse with  
clean water. Wipe with a soft, clean towel to prevent  
water spotting.  
2. Shut off water supply to the unit at the main water  
source and disconnect the supply line to the unit’s water  
valve.  
DANGER  
Interior Cleaning (As Required)  
RISK OF CHILD ENTRAPEMENT. Before you throw  
away your old refrigerator or freezer, take off the  
doors and leave shelves in place so that children  
may not easily climb inside.  
• Turn unit off. Clean the interior and all removed  
components using a mild non-abrasive detergent and  
warm water solution applied with a soft sponge or  
non-abrasive cloth. Rinse the interior using a soft  
sponge and clean water.  
3. Remove the cabinet door if equipped and secure all  
interior shelves to the interior of the cabinet using a  
heavy duty cloth or package sealing tape.  
• Do not use any solvent-based or abrasive  
cleaners. These types of cleaners may transmit  
taste to the interior products and damage or  
discolor the interior.  
BI95, BI98, SP18  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. Dampen a soft sponge or non-abrasive cloth in clean  
water and wipe down the cabinet interior and ice  
bucket to remove any detergent residue. Rinse the  
sponge or cloth in clean water and repeat as necessary  
until the cabinet and ice bucket are clean.  
Maintenance  
Proper maintenance of your U-Line product will ensure  
efficiency, top performance and long life. The  
maintenance intervals listed are based on normal  
conditions. You may want to shorten the intervals if you  
have pets or other special considerations.  
IMPORTANT  
DO NOT place ice bucket in dishwasher. Dishwasher  
will warp/discolor ice bucket and render it useless.  
Defrosting  
Manual Defrost Models - Every Two Months  
(Minimum)  
Condenser Cleaning  
Interval - Every Three Months  
WARNING  
To maintain operational efficiency, keep the front grille  
free of dust and lint, and clean the condenser every three  
months. Depending on environmental conditions, more  
or less frequent cleaning may be necessary.  
DO NOT use any type of electrical heating device,  
ice pick, knife or other sharp instrument to  
defrost; this could damage the inner lining or  
refrigeration system and void the warranty.  
WARNING  
Disconnect electric power to the unit before  
cleaning the condenser.  
To remove and replace the grille for access to the  
condenser fins, follow this procedure:  
1
ULIN_0238_A  
Figure 8  
ULIN_0239_A  
1. Disconnect electrical power to the unit.  
2. With a standard blade screwdriver or 1/4" nut driver,  
Figure 7  
To defrost:  
remove the grille screw (Figure 8, 1)  
.
3. Remove the grille.  
1. Turn unit off.  
2. Remove ice bucket and discard ice.  
WARNING  
3. Place a towel or other absorbent material on bottom of  
unit.  
DO NOT touch the condenser fins. The condenser  
fins are SHARP and can be easily damaged.  
4. If you would like, place warm water inside ice bucket.  
Then place ice bucket back into unit and close door.  
IMPORTANT  
DO NOT use any type of cleaner on the condenser  
unit.  
5. After approximately one hour, remove ice bucket and  
discard water.  
4. Clean the condenser coil using a soft brush with a  
“combing” action or vacuum cleaner. Do not touch the  
condenser coil.  
6. Allow the frost to completely melt naturally. Clean the  
interior and ice bucket using a mild non-abrasive  
detergent and warm water solution applied with a soft  
sponge or non-abrasive cloth. NOTE: DO NOT use any  
solvent-based or abrasive cleaners. They will discolor or  
damage the interior.  
5. Place the two hook-hinges (located on the rear bottom  
side of the grille) on the front lip of the unit base.  
Swing the grille up into position, aligning the grille and  
cabinet screw hole.  
10  
BI95, BI98, SP18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Insert the grille screw (Figure 8, 1) and tighten. Do not  
6. DO NOT remove the inlet screen from the water  
solenoid valve. Use a toothbrush to gently clean any  
sediment from the inlet screen.  
over-tighten.  
7. Reconnect power to the unit.  
Ice Maker Maintenance  
Inlet Screen  
7. Re-connect the water supply hose connector (Figure  
10, 1) to the water solenoid valve (Figure 10, 2)  
.
Tighten the connector securely.  
8. Open the water main supply valve and check for leaks  
at the water hose connection. Ensure that the water  
supply line is not kinked.  
Interval - Every Twelve Months  
The solenoid valve inlet screen must be cleaned at least  
once each year as follows:  
9. Place the two hook-hinges (located on the rear bottom  
side of the grille) on the front lip of the unit base.  
Swing the grille up into position, aligning the grille and  
cabinet screw hole.  
WARNING  
Disconnect electrical power to the unit before  
cleaning the solenoid valve.  
10. Insert the grille screw (Figure 9, 1) and tighten. Do not  
Models 95 and 98  
over-tighten.  
1. Disconnect electrical power to the unit.  
2. Shut off the water at the main supply valve.  
11. Reconnect power to the unit.  
Model SP18  
1. Disconnect electrical power to the unit.  
2. Shut off the water at the main supply valve.  
3. Pull the unit out to access the back panel.  
1
2
ULIN_0238_A  
Figure 9  
1
ULIN_0065_A  
3. With a standard blade screwdriver or 1/4" nut driver,  
remove the grille screw (Figure 9, 1)  
.
Figure 11  
4. Remove the grille.  
4. Disconnect the hose connector (Figure 11, 1) from the  
water solenoid valve (Figure 11, 2)  
.
WARNING  
5. DO NOT remove the inlet screen from the water  
solenoid valve. Use a toothbrush to gently clean any  
sediment from the inlet screen.  
DO NOT touch the condenser fins. The condenser  
fins are SHARP and can be easily damaged.  
6. Re-connect the water supply hose connector (Figure  
11, 1) to the water solenoid valve (Figure 11, 2)  
.
Tighten the connector securely.  
2
7. Open the water main supply valve and check for leaks  
at the water hose connection. Ensure that the water  
supply line is not kinked.  
8. Reconnect power to the unit before re-installing.  
1
ULIN_0064_A  
Figure 10  
5. Disconnect the hose connector (Figure 10, 1) from the  
water solenoid valve (Figure 10, 2)  
.
BI95, BI98, SP18  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ice Cube Thickness Adjustment  
Leveling  
Interval - As Required  
IMPORTANT  
The ice cube size may be adjusted by changing the  
amount of water injected into the ice maker assembly as  
follows:  
It is extremely important that the unit sits on a  
level surface, as it does not have feet levelers. If it  
is not level, the ice mold will not fill evenly.  
Use a level to check the levelness of the unit from front to  
back and from side to side. Level should be placed along  
top edge and side edge as shown (Figure 15, 1).  
ULIN_0237_A  
Figure 12  
1. Remove the ice maker assembly cover (Figure 12).  
1
ULIN_0309_A  
Figure 14  
ULIN_0056_A  
Figure 13  
2. Locate the adjusting screw on the ice maker assembly  
control box. The adjusting screw is just below the minus  
(-) and plus (+) signs on the control box (Figure 13)  
.
NOTE: Make adjustments in small increments. Too  
large of an adjustment could cause the unit to  
malfunction.  
3. Turn the adjusting screw toward the minus (-) sign  
(clockwise) for smaller cubes or toward the plus (+) sign  
(counterclockwise) for larger cubes.  
4. Install the ice maker assembly cover.  
IMPORTANT  
Use only genuine U-Line replacement parts. U-Line  
ice maker parts are not the same as standard FSP  
Whirlpool parts. Using non U-Line parts can reduce  
ice rate, cause water to overflow from ice maker  
mold, damage the unit and may void the warranty.  
12  
BI95, BI98, SP18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Door Alignment Check and Adjustment  
IMPORTANT  
Properly aligned, the door’s gasket should be firmly  
in contact with the cabinet all the way around the  
door (no gaps). Carefully examine the door’s gasket  
to assure that it is firmly in contact with the  
cabinet. Also make sure the door gasket is not  
pinched on the hinge side of the door.  
ULIN_0293_A  
Figure 17  
2. Remove top hinge from cabinet (three screws) (Figure  
17). Hold door to keep it from falling.  
3. Lift the door off the bottom hinge.  
ULIN_0293_A  
Figure 15  
1. Loosen (do not remove) top (Figure 15) and bottom  
hinge screws.  
2. Align door squarely with cabinet.  
3. Make sure gasket is firmly in contact with cabinet all  
the way around the door (no gaps).  
4. Tighten bottom hinge screws.  
5. Tighten top hinge screws.  
Door Reversal  
Figure 18  
Depending upon the location of the unit, it may be  
desirable to change the side on which the door is  
mounted.  
4. Remove bottom hinge from cabinet (two screws)  
(Figure 18)  
.
To reverse the door mounting, perform the following:  
1
ULIN_0137_A  
Figure 16  
ULIN_0122_A  
1. Remove grille (one screw) (Figure 16, 1).  
Figure 19  
BI95, BI98, SP18  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Remove screws on opposite side of cabinet (Figure 19)  
Note that there may be a nut behind one or both  
screws on either side.  
.
8. Remove plastic hole plug (Figure 22) from door handle  
and relocate on opposite side.  
9. Remove pivot screw from top hinge, invert screw and  
reinstall pivot screw in top hinge.  
ULIN_0144_A  
ULIN_0123_A  
Figure 23  
Figure 20  
10. Remove three plastic screw plugs (Figure 23) from  
hinge holes, top of cabinet, opposite side. Be careful  
not to scratch cabinet.  
6. Install hinge on opposite side, bottom of cabinet  
(Figure 20). Replace nut on back side where installed.  
Align hinge outer edge with cabinet before tightening  
screws.  
11. Place door on lower hinge pin. Invert and install upper  
hinge on door.  
1
ULIN_0109_A  
ULIN_0145_A  
Figure 21  
Figure 24  
7. Relocate plastic spacer/bushing (Figure 21) on bottom  
of door to opposite side, and place door on bottom  
hinge pin. Clean out bushing hole in door bottom with  
a screwdriver if necessary.  
12. Fasten upper hinge to unit (three screws) (Figure 24)  
.
Partially tighten screws.  
13. Adjust door to assure proper seal. Tighten upper and  
lower hinge screws securely.  
Hinge  
14. Replace three plastic plugs removed in Step 10 into  
holes on top of unit. Replace screws in holes in bottom  
of unit on opposite side.  
Plastic  
Plug Hole  
Plastic  
Plug Hole  
15. Replace the grille.  
Screw  
Right Side  
Door Swing  
Left Side  
Door Swing  
Right Side  
Hinge  
Invert  
Screw  
Invert  
Hinge  
ULIN_0142_A  
Figure 22  
14  
BI95, BI98, SP18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7 Service  
Before Calling for Service  
If your U-Line product appears to be malfunctioning, read  
through the OPERATION section of this guide to ensure  
that the function of all controls are clearly understood. If  
the malfunction persists, the TROUBLESHOOTING GUIDE  
in this guide will assist you in quickly identifying common  
problems, and provide information on possible causes and  
remedies. Most often, this will resolve the problem  
without the need to call for service.  
If Service is Required  
If you do not understand a troubleshooting remedy, or  
your product needs service, contact U-Line Corporation  
directly. Contact information appears on the rear cover of  
this guide.  
You will be asked for your product Model and Serial  
Numbers. This information should be recorded inside the  
front cover of this guide, following the products original  
purchase. It also appears on the Model and Serial number  
plate located on the upper right or rear wall of the  
interior of your product.  
Replacement Parts  
When you need replacement parts, always request that  
genuine U-Line replacements be used. U-Line products  
have been designed and engineered using components  
that work efficiently, and provide superior service life and  
performance. The use of aftermarket parts or components  
may affect the safety, operation, performance or  
durability of your product, and may also void its warranty.  
BI95, BI98, SP18  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting Guide  
DANGER  
ELECTROCUTION HAZARD  
Never attempt to repair or perform maintenance on  
the unit until the main electrical power has been  
disconnected.  
Troubleshooting - What to check when problems occur:  
PROBLEM  
POSSIBLE CAUSE  
REMEDY  
The unit frosts up.  
Unit is manual defrost model.  
Models SP18, 95, 98, CO29 and CO75 are manual defrost  
(See MAINTENANCE; DEFROSTING).  
Door gasket not sealing properly  
Adjust door (See MAINTENANCE; DOOR ALIGN, ADJUST,  
REVERSE).  
High ambient temperatures or  
humidity  
Defrost unit manually (See MAINTENANCE;  
DEFROSTING).  
Door left open  
Make sure door is closed.  
Tighten fitting as required.  
Water is leaking out the back of the Water supply connection leaking  
unit.  
Ice cubes sticking together  
Door gasket not sealing properly  
Adjust door (See MAINTENANCE; DOOR ALIGN, ADJUST,  
REVERSE).  
Infrequent use of cubes  
Break apart cubes.  
Noise during operation  
Copper water supply tubing  
contacting internal components  
Carefully bend tubing away from cabinet and  
components.  
Certain sounds are normal.  
Soft sounds from the fan and water/dropping sounds  
from the ice maker will be heard.  
Fan blade touching obstruction  
(wiring, foam insulation, etc.)  
Remove obstruction.  
No ice  
Bin arm locked in upright position  
No water to unit  
Lower bin arm.  
Turn on water or contact plumber.  
Adjust control to a warmer setting (See OPERATION).  
Not enough ice  
Control set too cold  
Ice cube size too large  
Set cube size smaller (See MAINTENANCE; ICE MAKER;  
ICE CUBE THICKNESS ADJUST).  
Dirty condenser coils  
Clean condenser (See MAINTENANCE; CONDENSER  
CLEANING).  
Water leaks into ice bucket.  
Water level set too high  
Set cube size smaller (See MAINTENANCE; ICE MAKER;  
ICE CUBE THICKNESS ADJUST).  
16  
BI95, BI98, SP18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
This page intentionally left blank  
BI95, BI98, SP18  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
This page intentionally left blank  
18  
BI95, BI98, SP18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
U-Line Corporation Limited Warranty  
U-Line Corporation warrants each U-Line product to be free from defects in materials and workmanship for a period of  
one year from the date of purchase; and warrants the sealed system (consisting of the compressor, the condenser, the  
evaporator, the hot gas bypass valve, the dryer and the connecting tubing) in each U-Line product to be free from  
defects in materials and workmanship for a period of five years from the date of purchase. During the initial one-year  
warranty period for all U-Line products U-Line shall: (1) at U-Lines option, repair any product or replace any part of a  
product that breaches this warranty; and (2) for all Marine, RV and Domestic U-Line products sold and serviced in the  
United States (including Alaska and Hawaii) and Canada, U-Line shall cover the labor costs incurred in connection with  
the replacement of any defective part. During years two through five of the warranty period for the sealed system, U-  
Line shall: (1) repair or replace any part of the sealed system that breaches this warranty; and (2) for all Marine, RV and  
Domestic U-Line products sold and serviced in the United States (including Alaska and Hawaii) and Canada, U-Line shall  
cover the labor costs incurred in connection with the replacement of any defective part of the sealed system. All other  
charges, including transportation charges for replacements under this warranty and labor costs not specifically covered  
by this warranty, shall be borne by you. This warranty is extended only to the original purchaser of the U-Line product.  
The Registration Card included with the product should be promptly completed by you and mailed back to U-Line or you  
The following are excluded from this limited warranty: installation charges; damages caused by disasters or acts of God,  
such as fire, floods, wind and lightening; damages incurred or resulting from shipping, improper installation,  
unauthorized modification, or misuse/abuse of the product; customer education calls; food loss/spoilage; door and water  
level adjustments (except during the first 90 days from the date of purchase); defrosting the product; adjusting the  
controls; door reversal; or cleaning the condenser.  
If a product defect is discovered during the applicable warranty period, you must promptly notify either the dealer from  
whom you purchased the product or U-Line at P.O. Box 245040, Milwaukee, Wisconsin 53224 or at 414-354-0300. In no  
event shall such notification be received later than 30 days after the expiration of the applicable warranty period. U-Line  
may require that defective parts be returned, at your expense, to U-Lines factory in Milwaukee, Wisconsin, for  
inspection. Any action by you for breach of warranty must be commenced within one year after the expiration of the  
applicable warranty period.  
This limited warranty is in lieu of any other warranty, express or implied, including, but not limited to any  
implied warranty of merchantability or fitness for a particular purpose; provided however, that to the  
extent required by law, implied warranties are included but do not extend beyond the duration of the  
express warranty first set forth above. U-Lines sole liability and your exclusive remedy under this warranty  
is set forth in the initial paragraph above. U-Line shall have no liability whatsoever for any incidental,  
consequential or special damages arising from the sale, use or installation of the product or from any other  
cause whatsoever, whether based on warranty (express or implied) or otherwise based on contract, tort or  
any other theory of liability.  
Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or  
consequential damages, so the above limitations may not apply to you. This warranty gives you specific legal rights, and  
you may also have other rights which vary from state to state.  
BI95, BI98, SP18  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fo r Ge n e ra l In q u irie s:  
P.O. Box 245040  
Milwaukee, Wisconsin  
53224-9540 U.S.A.  
Phone (800) 779-2547  
FAX (414) 354-5696  
www.U-Line.com  
Fo r Se rvice a n d Pa rt s  
Assist a n ce :  
Phone (800) 779-2547  
(414) 354-0300  
FAX (414) 354-5696  
Email:  
OnLineService@U-Line.com  
www.U-LineService.com  
E-mail:  
OnlineParts@u-line.com  
For more than four decades, U-Line has distinguished itself as the  
leader in built-in under-counter ice making, refrigeration and  
wine storage appliances.  
An INSTALLATION MANUAL for your unit, providing complete  
installation information, is available for download at  
www.U-Line.com. Information for custom panel inserts per model,  
including panel size, and instructions are available by visiting  
www.U-Line.com.  
When you need replacement parts, always request genuine U-Line  
replacements be used. Visit www.U-Line.com to locate a parts  
distributor in your area.  
U-Line Corporation, located in Milwaukee, WI, is a family operated manufacturer of built-in  
undercounter ice makers, Combo® ice maker/refrigerators, Wine Captain® wine storage units,  
refrigerators, refrigerated drawers and refrigerator/freezers.  
©2006 U-Line Corporation  
Publication No. 30098  
01/2006 Rev. A  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Texas Instruments Stereo Amplifier TAS5601 User Manual
Thule Network Hardware TK12 User Manual
Toshiba Computer Monitor TR2006R User Manual
Toshiba Laptop A65 User Manual
Toshiba Printer TRST A00 User Manual
Tyco Electronics Computer Monitor B1ET 1215L User Manual
Ultra Products Battery Charger ULT40033 User Manual
Uniden Telephone UIP312 User Manual
VDO Dayton MP3 Player TR 7327 B User Manual
VTech Two Way Radio REV IT UP IN RADIATOR SPRINGS User Manual