U Line Freezer 3018 CLR 115 V 60 Hz User Manual

QUICK START GUIDE  
Modular 3000 Series 3018 CLR 115 V / 60 Hz  
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUICK START GUIDE  
u-line.com  
Contents  
1
Model List  
2
Safety and Warning  
Environmental Requirements  
Water Hookup  
Drain  
2
3
4
6
Door Swing  
7
General Installation  
Control Quick Guide  
First Use  
8
8
8
Ice  
10  
10  
Sabbath Mode  
Warranty  
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUICK START GUIDE  
u-line.com  
Model List  
This guide provides the basics to get you started. Looking for more information? Visit u-line.com to view detailed User Guides  
for all U-Line products.  
Clear Ice Machines  
U-3018CLRS-00A  
U-3018CLRS-01A  
U-3018CLRS-40A  
U-3018CLRS-41A  
U-3018CLRINT-00A  
U-3018CLRINT-01A  
U-3018CLRINT-40A  
U-3018CLRINT-41A  
QR code to view all user guides online.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUICK START GUIDE  
u-line.com  
Safety and Warning  
Environmental Requirements  
This unit is designed to operate between 50°F (10°C) and  
100°F (38°C). Higher ambient temperatures may reduce  
the unit’s ability to reach low temperatures and/or reduce  
ice production on applicable models.  
NOTICE  
PLEASE READ all instructions before installing,  
operating, or servicing the appliance.  
Use this appliance for its intended purpose only and follow  
these general precautions with those listed throughout this  
guide.  
For best performance, keep the unit out of direct sunlight  
and away from heat generating equipment.  
In climates where high humidity and dew points are  
present, condensation may appear on outside surfaces.  
This is considered normal. The condensation will  
evaporate when the humidity drops.  
SAFETY ALERT DEFINITIONS  
Throughout this guide are safety items labeled with a  
Danger, Warning or Caution based on the risk type:  
DANGER  
!
CAUTION  
!
Danger means that failure to follow this safety  
statement will result in severe personal injury or  
death.  
Damages caused by ambient temperatures of  
40°F (5°C) or below are not covered by the  
warranty.  
WARNING  
!
Warning means that failure to follow this safety  
statement could result in serious personal injury  
or death.  
CAUTION  
!
Caution means that failure to follow this safety  
statement may result in minor or moderate  
personal injury, property or equipment damage.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUICK START GUIDE  
u-line.com  
Do not use Teflon tape or joint compound on the  
water fitting. The rubber washer provides an  
adequate seal. Other materials could cause  
blockage of the valve.  
Water Hookup  
PREPARE PLUMBING  
Please use the braided stainless steel water supply line  
which comes attached. The water line is fitted with a  
standard 1/4" (6.35 mm) compression fitting.  
Failure to follow recommendations and  
instructions may result in damage and/or harm,  
flooding or void the product warranty.  
WARNING  
!
Prior to installation, determine if this product  
contains a gravity style drain or factory installed  
drain pump. Products without a drain pump may  
only use a gravity style drain. Failure to connect  
water supply or drain line connections properly  
may result in water leakage, personal injury,  
and/or property damage. Disconnect power and  
turn off water to the unit before attempting to  
alter these connections. These connections are  
the responsibility of the owner and must be  
connected per local plumbing code. If you are  
uncertain of how to safely and properly install  
this product, contact a licensed plumber.  
CAUTION  
!
Turn off water supply and disconnect electrical  
supply to unit prior to installation.  
1. Turn off water supply and disconnect electrical supply  
to product prior to attempting installation.  
2. Locate the desired cold water supply location.  
3. Locate braided stainless steel  
water supply line and connect  
to your cold water supply. The  
water line should be looped into  
2 coils. This will allow the unit  
to be removed for cleaning and  
servicing. However, make  
Water Supply Connection  
CAUTION  
!
Review, obey, and understand the local  
plumbing codes before you install your unit.  
Connect to the cold water supply. The water  
pressure should be between 20 and 120 psi. The  
water line MUST have a shut-off valve on the  
supply line.  
certain that the tubing is not  
pinched or damaged during installation.  
4. Turn on water and check for leaks.  
CAUTION  
!
Do not use any plastic water supply line. The line  
is under pressure at all times. Plastic may crack  
or rupture with age and cause damage to your  
home.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUICK START GUIDE  
u-line.com  
5. Route water supply line in cable clamp and secure with  
screw.  
NOTICE  
Drain can NOT be located directly below the unit.  
Unit has a solid base that will not allow the unit  
to drain below itself.  
There is a possibility that hose connections may  
have loosened during shipment.  
Verify all connections and fittings are free from  
leaks.  
GRAVITY DRAIN  
Normal  
Proper Drain  
With Trap  
Poor Drainage, Water Will Back Up  
Drain  
Models ending in (-00A, -01A) will not be equipped with  
factory installed drain pump.  
With Trap and Vent  
Proper Drain  
A gravity drain may be used if:  
Models ending in (-40A, -41A) will have the factory  
installed drain pump.  
Drain line has at least a 1" drop per 48" (approximately  
2 cm drop per 100 cm) of run.  
DRAIN CONNECTION  
Drain line does not create traps and is vented per local  
code.  
CAUTION  
!
If your U-Line unit did not come with a factory  
installed drain pump you must use a gravity  
style drain connection. For assistance in  
1. Cut the pre-installed drain tube to length.  
2. Connect to your local plumbing per the local code.  
determining if your unit has a pump please  
contact U-Line. The floor drain must be large  
enough to accommodate drainage from all  
attached drains. Follow these guidelines when  
installing drain lines to prevent water from  
flowing back into the ice maker storage bin and/  
or potentially flowing onto the floor, which may  
result in personal injury or property damage.  
3. If necessary, insulate drain line to prevent  
condensation.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUICK START GUIDE  
u-line.com  
Y-Branch Tailpiece  
P60 Pump Required  
CAUTION  
!
Air Gap  
(Optional Hook-Up)  
Failure to connect water supply or drain line  
connections properly can result in personal  
injury and property damage. Gravity drain  
connections must be routed downward from the  
rest of the unit at the rate of 1/4" per foot (1 cm  
per 50 cm).  
Waste  
6KXWꢀ2ɞ  
Valve  
Cold  
Water  
Hot  
Water  
FACTORY INSTALLED DRAIN PUMP  
If your drain line will run up to a stand pipe, disposal or  
spigot assembly, or does not otherwise meet the  
requirements for a gravity drain, you may have ordered a  
pre-installed U-Line P60 drain pump.  
NOTICE  
The maximum lift for the P60 drain pump is  
10 feet. This must be done as close to the rear of  
the unit as possible.  
See below for typical installations requiring a drain pump.  
Stand Pipe  
P60 Pump Required  
Waste  
6KXWꢀ2ɞ  
Valve  
Cold  
Water  
Hot  
Water  
Waste  
Disposal Assembly  
P60 Pump Required  
Air Gap  
(Optional Hook-Up)  
Waste  
Cold  
Water  
Hot  
Water  
6KXWꢀ2ɞ  
Valve  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUICK START GUIDE  
u-line.com  
Door Swing  
Wall  
Units have a zero clearance when installed adjacent to  
cabinets.  
1/4" (6 mm)  
For Integrated models that are installed adjacent to a wall,  
1/4" (6 mm) clearance is recommended from wall on  
hinge side to allow the door to open 90°. Allow for  
additional space for any knobs or pulls installed on the  
integrated panel/frame.  
Stainless Steel models that are installed adjacent to a wall  
require 2-1/4" (57 mm) door clearance on hinge side to  
allow for door handle.  
90°  
Door Swing  
Space Required  
For any Knobs or Pulls  
Integrated  
2-1/4" MIN  
(57 mm MIN)  
Wall  
90°  
Door Swing  
Stainless  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUICK START GUIDE  
u-line.com  
INSTALLATION TIP  
General Installation  
If the room floor is higher than the floor in the cut-out  
opening, adjust the rear feet to achieve a total unit rear  
height of 1/8" (3 mm) less than the opening’s rear height.  
Shorten the unit height in the front by adjusting the front  
feet. This allows the unit to be gently tipped into the  
opening. Adjust the front feet to level the unit after it is  
correctly positioned in the opening.  
LEVELING INFORMATION  
1. Use a level to confirm  
the unit is level. Level  
should be placed along  
top edge and side  
1
edge as shown.  
INSTALLATION  
1. Plug in the power cord.  
2
2. Gently push the unit into position. Be careful to not  
entangle the power cord, water line and drain line.  
2. If the unit is not level, remove grille and adjust feet as  
necessary. Use included tool to adjust the height of the  
rear leveler feet. Turn screw clockwise to raise the rear  
foot, counter-clockwise to lower.  
3. Re-check the leveling, from front to back and side to  
side. Make any necessary adjustments. The unit’s top  
surface should be approximately 1/8" (3 mm) below  
the countertop.  
3. Confirm the unit is level after each adjustment and  
repeat the previous steps until the unit is level.  
4. Install the anti-tip bracket.  
5. Remove the tape from the glass shelves and wipe out  
the inside of the unit with a clean, water-dampened  
cloth.  
Rotate Forward Feet to Adjust  
Rotate Clockwise to raise rear leg.  
Rotate Counter-Clockwise to lower leg.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUICK START GUIDE  
u-line.com  
Control Quick Guide  
Actual Display:  
Zone Toggle  
Select  
Up  
ICE PRODUCTION  
Power  
U-Select Lighting  
Down  
Control Function Guide:  
FUNCTION  
COMMAND  
DISPLAY/OPTIONS  
OFF  
Press  
Press  
Press  
Press  
Press  
and hold  
Display will count down from 5 to off.  
ON  
and release  
Unit will come on immediately.  
Adjust lighting  
Customer menu  
Service menu  
to adjust lighting  
and hold for 5 seconds  
Press  
Press  
Press  
or  
or  
or  
to set low, medium or high.  
to scroll through menu.  
to scroll through menu.  
or  
and hold for 5 seconds  
First Use  
Ice  
All U-Line controls are preset at the factory. Initial startup  
requires no adjustments.  
ICE CUBE THICKNESS ADJUSTMENT  
NOTICE  
NOTICE  
Ice thickness adjustment should only be made  
one increment at a time. Allow ice maker  
production to stabilize for 24 hours before  
rechecking ice thickness.  
U-Line recommends discarding the ice produced  
during the first two to three hours of operation  
to avoid possible dirt or scale that may dislodge  
from the water line.  
Remove all ice from the storage bin.  
When plugged in, the unit will begin operating under the  
factory default setting. Follow the on screen prompt for  
language selection and temperature units.  
Ice cubes in any given batch will vary, so it is necessary  
to choose cubes from the sample area for comparison  
when making adjustments.  
To turn the unit off, press  
and hold for 5 seconds and  
release. The display will show a countdown to switching the  
unit off.  
The ice cube thickness is factory set for best overall  
performance. The factory setting “0” is designed to  
maintain an ice bridge of approximately 1/16" to 1/8"  
(1.6 mm to 3.2 mm) under normal conditions, resulting in  
a dimple of approximately 1/4" to 1/2" (6.4 mm to  
To power your unit on, simply press  
immediately switch on.  
. The unit will  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUICK START GUIDE  
u-line.com  
12.7 mm) in depth. A fuller cube with less of a dimple  
results in a thicker ice bridge. As the ice bridge thickens,  
the tendency for the cubes to stay together as a slab  
increases. A bridge thicker than 1/8" (3.2 mm) may cause  
cubes to overfill the ice bucket.  
ICE ADJUST  
Up  
Select  
RETURN TO MENU  
ICE ADJUST  
ICE ADJUST = 0  
Down  
Adjust ice thickness as follows:  
DIMPLES  
1. Press  
Customer Menu.  
and hold for 5 seconds to enter the  
and  
2. Press  
to select “Ice Adjust”.  
ICE BRIDGE  
3. Press  
. The selection will begin to flash.  
Ice Bridge and Dimples  
Your clear ice machine is pre-set to produce ice between  
the optimal dimensions illustrated below:  
4. Press  
to make the ice thicker or  
to make the ice  
thinner. Press  
to confirm your choice.  
Cube Types  
1/4" TO 1/2"  
(6.4 mm to 12.7 mm)  
DIMPLE  
1/16" TO 1/8"  
(1.6 mm to 3.2 mm)  
ICE BRIDGE  
The total range of adjustment is -5 (thinest) to +5  
(thickest). If further adjustments are desired, repeat  
Steps 1 through 4.  
THIN BRIDGE  
THICK BRIDGE  
LITTLE OR  
NO DIMPLE  
DEEP DIMPLE  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUICK START GUIDE  
u-line.com  
Warranty  
U-LINE CORPORATION LIMITED WARRANTY  
Sabbath Mode  
1. U-Line Corporation (“U-Line”) warrants each U-Line  
product to be free from defects in materials and  
workmanship for a period of one year (two years on  
Modular 3000 Series) from the date of purchase.  
U-Line further warrants the sealed system (consisting  
of the compressor, condenser, evaporator, hot gas  
bypass valve, dryer, and connecting tube) in each  
U-Line product to be free from defects in materials and  
workmanship for a period of five years from the date of  
purchase.  
Up  
RETURN TO MENU  
SABBATH MODE  
OFF?  
Power  
Down  
U-Line Clear Ice Machine models are Star-K certified and  
can be used during the Sabbath. View a full list of Star-K  
2. During the initial one year warranty period (two years  
on Modular 3000 Series) for all U-Line products U-Line  
shall: (1) repair any product or replace any part of a  
product; and (2) for all Marine, RV and Domestic  
U-Line products sold and serviced in the United States  
(including Alaska and Hawaii) and Canada, U-Line  
shall be responsible for the labor costs performed by a  
U-Line authorized service company, incurred in  
connection with the replacement of any defective part.  
During years two through five of the warranty period  
for the sealed system, U-Line shall: (1) at U-Line’s  
option repair or replace any part of the sealed system;  
and (2) for all Marine, RV and Domestic U-Line  
products sold and serviced in the United States  
(including Alaska and Hawaii) and Canada, U-Line shall  
be responsible for the labor costs incurred in  
To prepare the unit for the Sabbath:  
1. Press  
and hold until the unit turns off.  
2. No new ice will form when the unit is off, but previously  
made ice will still be accessible/present for over 24  
hours. Pump equipped models will continue to remove  
water as needed even if the unit is off.  
Sabbath Mode remains active until  
and the unit turns on.  
is pressed again  
connection with the replacement of any defective part  
of the sealed system. All other charges, including  
transportation charges for replacements under this  
warranty and labor costs not specifically covered by  
this warranty, shall be the responsibility of the  
purchaser. This warranty extends only to the original  
purchaser of the U-Line product. The Product  
Registration Card included with the product should be  
promptly completed by you and mailed back to U-Line  
3. The warranty listed above does not apply to floor  
display models. The warranty for these models shall  
be 30 days from the date of retail purchase and only if  
U-Line’s Product Registration Card included with the  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUICK START GUIDE  
u-line.com  
unit is completed and mailed back or electronically  
submitted to U-Line. This 30 day warranty does not  
apply to cosmetic damages. A proof of purchase may  
be required.  
of pool water, or directing a spray from a hose or  
similar device into and around the unit.  
7. If a product defect is discovered during the applicable  
warranty period, you must promptly notify either  
U-Line at 8900 N. 55th Street, Milwaukee, Wisconsin  
53223 USA or at +1.800.779.2547 or the dealer from  
whom you purchased the product. In no event shall  
such notification be received later than 30 days after  
the expiration of the applicable warranty period. U-Line  
may require that defective parts be returned, at your  
expense, to U-Line’s factory in Milwaukee, Wisconsin,  
for inspection. Any action by you for breach of  
warranty must be commenced within one year after  
the applicable warranty period.  
4. The following conditions are excluded from this limited  
warranty: use of cleaners other than the recommended  
stainless steel cleaners and U-Line Clear Ice Maker  
cleaner; installation charges; damages caused by  
disasters or acts of God, such as fire, floods, wind and  
lightning; damages incurred or resulting from shipping,  
improper installation, unauthorized modification, or  
misuse/abuse of the product; customer education  
calls; food loss and spoilage; door and water level  
adjustments (except during the first 30 days from the  
date of installation); defrosting the product; adjusting  
the controls; door reversal; and cleaning the  
condenser.  
8. THIS LIMITED WARRANTY IS IN LIEU OF ANY AND ALL  
OTHER WARRANTIES, EXPRESS OR IMPLIED,  
INCLUDING ANY IMPLIED WARRANTY OF  
5. U-Line products are designed to operate in ambient  
temperatures between 50°F and 100°F unless  
otherwise noted in the product manual. Exposure to  
temperatures outside this range may cause  
degradation of performance and issues such as lower  
ice production or spoiled contents that are not covered  
under the terms of this warranty as a result of that  
exposure. U-Line product may not be subjected to  
temperatures below 40°F without following the  
winterization and vacation shutdown procedures in the  
user guide.  
MERCHANTABILITY OR IMPLIED WARRANTY OF  
FITNESS FOR A PARTICULAR PURPOSE, ALL OF WHICH  
ARE DISCLAIMED. U-Line’s sole liability and your  
exclusive remedy under this warranty are set forth in  
the paragraphs above. U-Line shall have no liability  
whatsoever for any incidental, consequential or special  
damages arising from the sale, use or installation of  
the product or from any other cause whatsoever,  
whether based on warranty (express or implied) or  
otherwise based on contract, tort or any other theory  
of liability.  
6. U-Line’s Outdoor Limited Warranty, set forth in this  
Paragraph 6, shall apply to U-Line models deemed  
suitable for outdoor use by Underwriters Laboratory  
(“UL”) as noted in the U-Line Product Catalog, U-Line’s  
website and/or on the serial tag located inside the  
product.  
Some states do not allow limitations on how long an  
implied warranty lasts or the exclusion or limitation of  
incidental or consequential damages, so the above  
limitations may not apply to you. This warranty gives you  
specific legal rights, and you may also have other rights  
which vary from state to state.  
A. Outdoor product may come into contact with rain by  
virtue of outdoor use. Exposure to other sources of  
water shall also cause this warranty to be void,  
Warranty 6/2014 Rev.G  
including flooding of the area in proximity of the unit  
greater than 1/8" deep in water, hurricanes, splashing  
Copyright © 2014 U-Line Corporation. All Rights Reserved.  
Publication Number 30426 8/2014 Rev.A  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Teac Stereo Amplifier AI 501DA User Manual
Technicolor Thomson Universal Remote M8521C User Manual
Tripp Lite Network Cables P561 100 EZ User Manual
Tripp Lite Surge Protector ISOTEL6ULTRA User Manual
Tyan Computer Computer Hardware S1854 User Manual
Tyan Computer Network Card B2881 User Manual
Uniden Cordless Drill EXV 958 User Manual
United States Stove Automobile Alarm 2421 User Manual
VistaQuest Digital Camera sensor 505 D User Manual
Watlow Electric Electric Heater FREEZE SAFE User Manual