QUICK START GUIDE
Modular 3000 Series • 3018 CLR • 115 V / 60 Hz
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICK START GUIDE
u-line.com
Contents
1
Model List
2
Safety and Warning
Environmental Requirements
Water Hookup
Drain
2
3
4
6
Door Swing
7
General Installation
Control Quick Guide
First Use
8
8
8
Ice
10
10
Sabbath Mode
Warranty
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICK START GUIDE
u-line.com
Model List
This guide provides the basics to get you started. Looking for more information? Visit u-line.com to view detailed User Guides
for all U-Line products.
Clear Ice Machines
U-3018CLRS-00A
U-3018CLRS-01A
U-3018CLRS-40A
U-3018CLRS-41A
U-3018CLRINT-00A
U-3018CLRINT-01A
U-3018CLRINT-40A
U-3018CLRINT-41A
QR code to view all user guides online.
1
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICK START GUIDE
u-line.com
Safety and Warning
Environmental Requirements
This unit is designed to operate between 50°F (10°C) and
100°F (38°C). Higher ambient temperatures may reduce
the unit’s ability to reach low temperatures and/or reduce
ice production on applicable models.
NOTICE
PLEASE READ all instructions before installing,
operating, or servicing the appliance.
Use this appliance for its intended purpose only and follow
these general precautions with those listed throughout this
guide.
For best performance, keep the unit out of direct sunlight
and away from heat generating equipment.
In climates where high humidity and dew points are
present, condensation may appear on outside surfaces.
This is considered normal. The condensation will
evaporate when the humidity drops.
SAFETY ALERT DEFINITIONS
Throughout this guide are safety items labeled with a
Danger, Warning or Caution based on the risk type:
DANGER
!
CAUTION
!
Danger means that failure to follow this safety
statement will result in severe personal injury or
death.
Damages caused by ambient temperatures of
40°F (5°C) or below are not covered by the
warranty.
WARNING
!
Warning means that failure to follow this safety
statement could result in serious personal injury
or death.
CAUTION
!
Caution means that failure to follow this safety
statement may result in minor or moderate
personal injury, property or equipment damage.
2
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICK START GUIDE
u-line.com
Do not use Teflon tape or joint compound on the
water fitting. The rubber washer provides an
adequate seal. Other materials could cause
blockage of the valve.
Water Hookup
PREPARE PLUMBING
Please use the braided stainless steel water supply line
which comes attached. The water line is fitted with a
standard 1/4" (6.35 mm) compression fitting.
Failure to follow recommendations and
instructions may result in damage and/or harm,
flooding or void the product warranty.
WARNING
!
Prior to installation, determine if this product
contains a gravity style drain or factory installed
drain pump. Products without a drain pump may
only use a gravity style drain. Failure to connect
water supply or drain line connections properly
may result in water leakage, personal injury,
and/or property damage. Disconnect power and
turn off water to the unit before attempting to
alter these connections. These connections are
the responsibility of the owner and must be
connected per local plumbing code. If you are
uncertain of how to safely and properly install
this product, contact a licensed plumber.
CAUTION
!
Turn off water supply and disconnect electrical
supply to unit prior to installation.
1. Turn off water supply and disconnect electrical supply
to product prior to attempting installation.
2. Locate the desired cold water supply location.
3. Locate braided stainless steel
water supply line and connect
to your cold water supply. The
water line should be looped into
2 coils. This will allow the unit
to be removed for cleaning and
servicing. However, make
Water Supply Connection
CAUTION
!
Review, obey, and understand the local
plumbing codes before you install your unit.
Connect to the cold water supply. The water
pressure should be between 20 and 120 psi. The
water line MUST have a shut-off valve on the
supply line.
certain that the tubing is not
pinched or damaged during installation.
4. Turn on water and check for leaks.
CAUTION
!
Do not use any plastic water supply line. The line
is under pressure at all times. Plastic may crack
or rupture with age and cause damage to your
home.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICK START GUIDE
u-line.com
5. Route water supply line in cable clamp and secure with
screw.
NOTICE
Drain can NOT be located directly below the unit.
Unit has a solid base that will not allow the unit
to drain below itself.
There is a possibility that hose connections may
have loosened during shipment.
Verify all connections and fittings are free from
leaks.
GRAVITY DRAIN
Normal
Proper Drain
With Trap
Poor Drainage, Water Will Back Up
Drain
Models ending in (-00A, -01A) will not be equipped with
factory installed drain pump.
With Trap and Vent
Proper Drain
A gravity drain may be used if:
Models ending in (-40A, -41A) will have the factory
installed drain pump.
Drain line has at least a 1" drop per 48" (approximately
2 cm drop per 100 cm) of run.
DRAIN CONNECTION
Drain line does not create traps and is vented per local
code.
CAUTION
!
If your U-Line unit did not come with a factory
installed drain pump you must use a gravity
style drain connection. For assistance in
1. Cut the pre-installed drain tube to length.
2. Connect to your local plumbing per the local code.
determining if your unit has a pump please
contact U-Line. The floor drain must be large
enough to accommodate drainage from all
attached drains. Follow these guidelines when
installing drain lines to prevent water from
flowing back into the ice maker storage bin and/
or potentially flowing onto the floor, which may
result in personal injury or property damage.
3. If necessary, insulate drain line to prevent
condensation.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICK START GUIDE
u-line.com
Y-Branch Tailpiece
P60 Pump Required
CAUTION
!
Air Gap
(Optional Hook-Up)
Failure to connect water supply or drain line
connections properly can result in personal
injury and property damage. Gravity drain
connections must be routed downward from the
rest of the unit at the rate of 1/4" per foot (1 cm
per 50 cm).
Waste
6KXWꢀ2ɞ
Valve
Cold
Water
Hot
Water
FACTORY INSTALLED DRAIN PUMP
If your drain line will run up to a stand pipe, disposal or
spigot assembly, or does not otherwise meet the
requirements for a gravity drain, you may have ordered a
pre-installed U-Line P60 drain pump.
NOTICE
The maximum lift for the P60 drain pump is
10 feet. This must be done as close to the rear of
the unit as possible.
See below for typical installations requiring a drain pump.
Stand Pipe
P60 Pump Required
Waste
6KXWꢀ2ɞ
Valve
Cold
Water
Hot
Water
Waste
Disposal Assembly
P60 Pump Required
Air Gap
(Optional Hook-Up)
Waste
Cold
Water
Hot
Water
6KXWꢀ2ɞ
Valve
5
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICK START GUIDE
u-line.com
Door Swing
Wall
Units have a zero clearance when installed adjacent to
cabinets.
1/4" (6 mm)
For Integrated models that are installed adjacent to a wall,
1/4" (6 mm) clearance is recommended from wall on
hinge side to allow the door to open 90°. Allow for
additional space for any knobs or pulls installed on the
integrated panel/frame.
Stainless Steel models that are installed adjacent to a wall
require 2-1/4" (57 mm) door clearance on hinge side to
allow for door handle.
90°
Door Swing
Space Required
For any Knobs or Pulls
Integrated
2-1/4" MIN
(57 mm MIN)
Wall
90°
Door Swing
Stainless
6
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICK START GUIDE
u-line.com
INSTALLATION TIP
General Installation
If the room floor is higher than the floor in the cut-out
opening, adjust the rear feet to achieve a total unit rear
height of 1/8" (3 mm) less than the opening’s rear height.
Shorten the unit height in the front by adjusting the front
feet. This allows the unit to be gently tipped into the
opening. Adjust the front feet to level the unit after it is
correctly positioned in the opening.
LEVELING INFORMATION
1. Use a level to confirm
the unit is level. Level
should be placed along
top edge and side
1
edge as shown.
INSTALLATION
1. Plug in the power cord.
2
2. Gently push the unit into position. Be careful to not
entangle the power cord, water line and drain line.
2. If the unit is not level, remove grille and adjust feet as
necessary. Use included tool to adjust the height of the
rear leveler feet. Turn screw clockwise to raise the rear
foot, counter-clockwise to lower.
3. Re-check the leveling, from front to back and side to
side. Make any necessary adjustments. The unit’s top
surface should be approximately 1/8" (3 mm) below
the countertop.
3. Confirm the unit is level after each adjustment and
repeat the previous steps until the unit is level.
4. Install the anti-tip bracket.
5. Remove the tape from the glass shelves and wipe out
the inside of the unit with a clean, water-dampened
cloth.
Rotate Forward Feet to Adjust
Rotate Clockwise to raise rear leg.
Rotate Counter-Clockwise to lower leg.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICK START GUIDE
u-line.com
Control Quick Guide
Actual Display:
Zone Toggle
Select
Up
ICE PRODUCTION
Power
U-Select Lighting
Down
Control Function Guide:
FUNCTION
COMMAND
DISPLAY/OPTIONS
OFF
Press
Press
Press
Press
Press
and hold
Display will count down from 5 to off.
ON
and release
Unit will come on immediately.
Adjust lighting
Customer menu
Service menu
to adjust lighting
and hold for 5 seconds
Press
Press
Press
or
or
or
to set low, medium or high.
to scroll through menu.
to scroll through menu.
or
and hold for 5 seconds
First Use
Ice
All U-Line controls are preset at the factory. Initial startup
requires no adjustments.
ICE CUBE THICKNESS ADJUSTMENT
NOTICE
NOTICE
Ice thickness adjustment should only be made
one increment at a time. Allow ice maker
production to stabilize for 24 hours before
rechecking ice thickness.
U-Line recommends discarding the ice produced
during the first two to three hours of operation
to avoid possible dirt or scale that may dislodge
from the water line.
Remove all ice from the storage bin.
When plugged in, the unit will begin operating under the
factory default setting. Follow the on screen prompt for
language selection and temperature units.
Ice cubes in any given batch will vary, so it is necessary
to choose cubes from the sample area for comparison
when making adjustments.
To turn the unit off, press
and hold for 5 seconds and
release. The display will show a countdown to switching the
unit off.
The ice cube thickness is factory set for best overall
performance. The factory setting “0” is designed to
maintain an ice bridge of approximately 1/16" to 1/8"
(1.6 mm to 3.2 mm) under normal conditions, resulting in
a dimple of approximately 1/4" to 1/2" (6.4 mm to
To power your unit on, simply press
immediately switch on.
. The unit will
8
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICK START GUIDE
u-line.com
12.7 mm) in depth. A fuller cube with less of a dimple
results in a thicker ice bridge. As the ice bridge thickens,
the tendency for the cubes to stay together as a slab
increases. A bridge thicker than 1/8" (3.2 mm) may cause
cubes to overfill the ice bucket.
ICE ADJUST
Up
Select
RETURN TO MENU
ICE ADJUST
ICE ADJUST = 0
Down
Adjust ice thickness as follows:
DIMPLES
1. Press
Customer Menu.
and hold for 5 seconds to enter the
and
2. Press
to select “Ice Adjust”.
ICE BRIDGE
3. Press
. The selection will begin to flash.
Ice Bridge and Dimples
Your clear ice machine is pre-set to produce ice between
the optimal dimensions illustrated below:
4. Press
to make the ice thicker or
to make the ice
thinner. Press
to confirm your choice.
Cube Types
1/4" TO 1/2"
(6.4 mm to 12.7 mm)
DIMPLE
1/16" TO 1/8"
(1.6 mm to 3.2 mm)
ICE BRIDGE
The total range of adjustment is -5 (thinest) to +5
(thickest). If further adjustments are desired, repeat
Steps 1 through 4.
THIN BRIDGE
THICK BRIDGE
LITTLE OR
NO DIMPLE
DEEP DIMPLE
9
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICK START GUIDE
u-line.com
Warranty
U-LINE CORPORATION LIMITED WARRANTY
Sabbath Mode
1. U-Line Corporation (“U-Line”) warrants each U-Line
product to be free from defects in materials and
workmanship for a period of one year (two years on
Modular 3000 Series) from the date of purchase.
U-Line further warrants the sealed system (consisting
of the compressor, condenser, evaporator, hot gas
bypass valve, dryer, and connecting tube) in each
U-Line product to be free from defects in materials and
workmanship for a period of five years from the date of
purchase.
Up
RETURN TO MENU
SABBATH MODE
OFF?
Power
Down
U-Line Clear Ice Machine models are Star-K certified and
can be used during the Sabbath. View a full list of Star-K
2. During the initial one year warranty period (two years
on Modular 3000 Series) for all U-Line products U-Line
shall: (1) repair any product or replace any part of a
product; and (2) for all Marine, RV and Domestic
U-Line products sold and serviced in the United States
(including Alaska and Hawaii) and Canada, U-Line
shall be responsible for the labor costs performed by a
U-Line authorized service company, incurred in
connection with the replacement of any defective part.
During years two through five of the warranty period
for the sealed system, U-Line shall: (1) at U-Line’s
option repair or replace any part of the sealed system;
and (2) for all Marine, RV and Domestic U-Line
products sold and serviced in the United States
(including Alaska and Hawaii) and Canada, U-Line shall
be responsible for the labor costs incurred in
To prepare the unit for the Sabbath:
1. Press
and hold until the unit turns off.
2. No new ice will form when the unit is off, but previously
made ice will still be accessible/present for over 24
hours. Pump equipped models will continue to remove
water as needed even if the unit is off.
Sabbath Mode remains active until
and the unit turns on.
is pressed again
connection with the replacement of any defective part
of the sealed system. All other charges, including
transportation charges for replacements under this
warranty and labor costs not specifically covered by
this warranty, shall be the responsibility of the
purchaser. This warranty extends only to the original
purchaser of the U-Line product. The Product
Registration Card included with the product should be
promptly completed by you and mailed back to U-Line
3. The warranty listed above does not apply to floor
display models. The warranty for these models shall
be 30 days from the date of retail purchase and only if
U-Line’s Product Registration Card included with the
10
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICK START GUIDE
u-line.com
unit is completed and mailed back or electronically
submitted to U-Line. This 30 day warranty does not
apply to cosmetic damages. A proof of purchase may
be required.
of pool water, or directing a spray from a hose or
similar device into and around the unit.
7. If a product defect is discovered during the applicable
warranty period, you must promptly notify either
U-Line at 8900 N. 55th Street, Milwaukee, Wisconsin
53223 USA or at +1.800.779.2547 or the dealer from
whom you purchased the product. In no event shall
such notification be received later than 30 days after
the expiration of the applicable warranty period. U-Line
may require that defective parts be returned, at your
expense, to U-Line’s factory in Milwaukee, Wisconsin,
for inspection. Any action by you for breach of
warranty must be commenced within one year after
the applicable warranty period.
4. The following conditions are excluded from this limited
warranty: use of cleaners other than the recommended
stainless steel cleaners and U-Line Clear Ice Maker
cleaner; installation charges; damages caused by
disasters or acts of God, such as fire, floods, wind and
lightning; damages incurred or resulting from shipping,
improper installation, unauthorized modification, or
misuse/abuse of the product; customer education
calls; food loss and spoilage; door and water level
adjustments (except during the first 30 days from the
date of installation); defrosting the product; adjusting
the controls; door reversal; and cleaning the
condenser.
8. THIS LIMITED WARRANTY IS IN LIEU OF ANY AND ALL
OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING ANY IMPLIED WARRANTY OF
5. U-Line products are designed to operate in ambient
temperatures between 50°F and 100°F unless
otherwise noted in the product manual. Exposure to
temperatures outside this range may cause
degradation of performance and issues such as lower
ice production or spoiled contents that are not covered
under the terms of this warranty as a result of that
exposure. U-Line product may not be subjected to
temperatures below 40°F without following the
winterization and vacation shutdown procedures in the
user guide.
MERCHANTABILITY OR IMPLIED WARRANTY OF
FITNESS FOR A PARTICULAR PURPOSE, ALL OF WHICH
ARE DISCLAIMED. U-Line’s sole liability and your
exclusive remedy under this warranty are set forth in
the paragraphs above. U-Line shall have no liability
whatsoever for any incidental, consequential or special
damages arising from the sale, use or installation of
the product or from any other cause whatsoever,
whether based on warranty (express or implied) or
otherwise based on contract, tort or any other theory
of liability.
6. U-Line’s Outdoor Limited Warranty, set forth in this
Paragraph 6, shall apply to U-Line models deemed
suitable for outdoor use by Underwriters Laboratory
(“UL”) as noted in the U-Line Product Catalog, U-Line’s
website and/or on the serial tag located inside the
product.
Some states do not allow limitations on how long an
implied warranty lasts or the exclusion or limitation of
incidental or consequential damages, so the above
limitations may not apply to you. This warranty gives you
specific legal rights, and you may also have other rights
which vary from state to state.
A. Outdoor product may come into contact with rain by
virtue of outdoor use. Exposure to other sources of
water shall also cause this warranty to be void,
Warranty 6/2014 Rev.G
including flooding of the area in proximity of the unit
greater than 1/8" deep in water, hurricanes, splashing
Copyright © 2014 U-Line Corporation. All Rights Reserved.
Publication Number 30426 8/2014 Rev.A
11
Download from Www.Somanuals.com. All Manuals Search And Download.
|