TRUE FOOD SERVICE EQUIPMENT, INC.
2001 East Terra Lane • P.O. Box 970 • O’Fallon, Missouri 63366
(636)-240-2400 • FAX (636)272-2408 • INT’L FAX (636)272-7546 • (800)325-6152
Parts Department (800)424-TRUE • Parts Department FAX# (636)272-9471
INSTALLATION MANUAL FOR GDIM
(GLASS DOOR ICE MERCHANDISERS)
TABLE OF CONTENTS
Safety Information
Safety Precautions
Do’s and Don’ts
1
2
3
4
4
Proper Disposal
Connecting Electricity
Adapter Plugs
Installation / Operation Instructions
Ownership
5
Required Tools
5
Uncrating
5
Locating & Installation of Leg/Castors
Leveling Cabinet
6
7
Wire Gauge Chart
8
Sealing Cabinet to Floor & Electrical Inst.
Start-up and Light Switch Location
Defrost Time Clock Operation (Grasslin)
Field Troubleshooting
9
GDIM-26
10
11
12-13
Maintenance, Care & Cleaning
Cleaning Condenser Coil
Cabinet Cleaning
14-15
16-17
17
Light Bulb Replacement
GDIM-26NT
Warranty (U.S.A. & Canada Only!)
18
*Spanish, German, French and Dutch versions included.
CONGRATULATIONS!
You have just purchased the finest commercial
freezer available. You can expect many years of
trouble-free operation.
GDIM-49
G D I M - G L A S S D O O R
I C E M E R C H A N D I S E R S
6/6/08-500 SB #897013
Download from Www.Somanuals.com. All Manuals Search And Download.
True Food Service Equipment, Inc.
SAFETY INFORMATION
How to Maintain Your
Freezer
to Receive the Most Efficient and
Successful Operation
You have selected one of the finest commercial freezer units made. It is
manufactured under strict quality controls with only the best quality materials
available. Your TRUE freezer when properly maintained will give you many
years of trouble-free service.
WARNING!
Use this appliance for its intended purpose as described in this Owner Manual.
SAFETY PRECAUTIONS
When using electrical appliances, basic safety precautions should be followed, including the following:
This freezer must be properly installed and
located in accordance with the Installation
Instructions before it is used.
NOTE: We strongly recommend that any
servicing be preformed by a qualified
individual.
Do not allow children to climb, stand or hang
on the shelves in the freezer. They could
damage the freezer and seriously injure
themselves.
Unplug the freezer before cleaning and making
repairs.
Setting temperature controls to the 0 position
does not remove power to the light circuit,
perimeter heaters, or evaporator fans.
Do not touch the cold surfaces in the freezer
compartment when hands are damp or wet.
Skin may stick to these extremely cold surfaces.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
Keep fingers out of the“pinch point”areas;
clearances between the doors and between the
doors and cabinet are necessarily small; be
careful closing doors when children are in the
area.
1
1
Download from Www.Somanuals.com. All Manuals Search And Download.
True Food Service Equipment, Inc.
SAFETY INFORMATION
2
2
Download from Www.Somanuals.com. All Manuals Search And Download.
True Food Service Equipment, Inc.
SAFETY INFORMATION
DANGER!
RISK OF CHILD ENTRAPMENT
PROPER DISPOSAL OF THE REFRIGERATOR
Child entrapment and suffocation are not problems
of the past. Junked or abandoned refrigerators are
still dangerous… even if they will sit for“just a few
days.” If you are getting rid of your old refrigerator,
please follow the instructions below to help
prevent accidents.
Refrigerant Disposal
Your old refrigerator may have a cooling system
that uses“Ozone Depleting ”chemicals. If you are
throwing away your old refrigerator, make sure the
refrigerant is removed for proper disposal by a
qualified service technician. If you intentionally
release any refrigerants you can be subject to
fines and imprisonment under provisions of the
environmental regulations.
Before You Throw Away Your Old Refrigerator
or Freezer:
Take off the doors.
Leave the shelves in place so that children may
not easily climb inside.
USE OF EXTENSION CORDS
NEVER USE AN EXTENSION CORD! TRUE will not warranty any freezer that has been
connected to an extension cord.
3
3
Download from Www.Somanuals.com. All Manuals Search And Download.
True Food Service Equipment, Inc.
SAFETY INFORMATION
WARNING!
HOW TO CONNECT ELECTRICITY
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
For personal safety, this appliance must be properly grounded.
The power cord of this appliance is equipped with
a 3-prong (grounding) plug which mates with a
standard 3-prong (grounding) wall outlet to
minimize the possibility of electric shock hazard
from this appliance.
could cause a fire hazard from overheated wires.
Never unplug your freezer by pulling on the power
cord. Always grip plug firmly and pull straight out
from the outlet.
Repair or replace immediately all power cords that
have become frayed or otherwise damaged. Do not
use a cord that shows cracks or abrasion damage
along its length or at either end.
Have the wall outlet and circuit checked by a
qualified electrician to make sure the outlet is
properly grounded.
If the outlet is a standard 2-prong outlet, it is your
personal responsibility and obligation to have it
replaced with the properly grounded 3-prong wall
outlet.
When removing the freezer away from the wall, be
careful not to roll over or damage the power cord.
The freezer should always be plugged into it’s own
individual electrical circuit, which has a voltage
rating that matches the rating plate.
This provides the best performance and also
prevents overloading building wiring circuits which
USE OF ADAPTER PLUGS
NEVER USE AN ADAPTER PLUG! Because of potential safety hazards under certain conditions, we
strongly recommend against the use of an adapter plug.
The incoming power source to the cabinet
North America Use Only!
including any adapters used must have the adequate
power available and must be properly grounded.
NEMA plugs
TRUE uses these types of plugs.
If you do not have the right outlet
have a certified electrician install
the correct power source.
4
4
Download from Www.Somanuals.com. All Manuals Search And Download.
True Food Service Equipment, Inc.
INSTALLATION / OPERATION INSTRUCTIONS
INSTALLATION / OPERATION INSTRUCTIONS
OWNERSHIP
To insure that your unit works properly from the
first day, it must be installed properly. We highly
recommend a trained refrigeration mechanic and
electrician install your True equipment. The cost
of a professional installation is money well spent.
Before you start to install your True unit, carefully
inspect it for freight damage. If damage is
discovered, immediately file a claim with the
delivery freight carrier.
True is not responsible for damage incurred
during shipment.
REQUIRED TOOLS
Adjustable Wrench
Phillips Head Screwdriver
Level
UNCRATING
Step 1
The following procedure is recommended for
uncrating the unit:
A. Remove the outer packaging, (cardboard and
bubbles or styrofoam corners and clear plastic).
Inspect for concealed damage.Again,
immediately file a claim with the freight carrier
if there is damage.
1
2
B. Move your unit as close to the final location as
possible before removing the wooden skid.
C. Remove door bracket on swinging glass door
models (see image 1-2).
Note: Keys for coolers with door locks are located
in warranty packets.
REMOTE UNITS (This section applies to
remotes only!)
• Remote cabinets must be ordered as remote.
We do not recommend converting for a standard
self contained to remote system.
• Contact True Technical Service for BTU
requirements.
• No wiring necessary between cabinet and
condensing unit.
• All remote cabinets must be hard wired.
• No castors available.
• All remote condensing units purchased from
True are 208/230 volts single phase.
• All remote cabinets come standard using 404A
refrigerant.
If you have any questions regarding this
section, please call True at 1-(800)-325-6152.
• All remote units come standard with expansion
valve, liquid line solenoid, heated condensate
pan, and defrost timer when applicable.
5
5
Download from Www.Somanuals.com. All Manuals Search And Download.
True Food Service Equipment, Inc.
INSTALLATION / OPERATION INSTRUCTIONS
LOCATING
Step 2
C. Carefully upright cabinet.
A. Carefully lay the unit on its back to remove skid.
Place packing material behind cabinet as a cushion.
When lifting unit remember to
Removing
skid from
bottom of
cabinet.
leave the cabinet upright for 24 hours before
plugging into power source.
B. Remove skid by unscrewing all base rail anchor
brackets. Place skid to the side.
INSTALLATION OF LEGS AND CASTORS
Important Safeguard for installation of leg/castor (Images 1-5 demonstrate procedure)
side. (diagonally)
Step 3
Securing Castors and Legs
To obtain maximum strength and stability of the
B. Install the desired number of shims, making sure
the slot of the shim is in contact with the threaded
stem of the castor.
unit, it is important that you make sure each castor
is secure. Legs are hand-tightened securely against
the lower rail assembly. The bearing race on the
castor of the top edge of the leg must make firm
contact with the rail.
C. If more than one shim is used, turn the slot at a
90° angle so they are not in line.
D. Turn the bearing race clockwise to tighten and
secure the castor by tightening the anchoring bolt
with a 3/4 inch open-end wrench or the tool
provided.
Unit leveling
Four leveling shims have been provided for
leveling castored units positioned on uneven
floors. Shims must be positioned between rail
end and bearing race.
CAUTION
To avoid damage to lower rail assembly,
slowly raise unit to upright position.
Note: Open holes located on the cross members of the
frame rail should be plugged before unit is in use.
A. Turn the bearing race counter-clockwise until
the cabinet is level. Level front to back and side to
1
2
4
3
Thread castor into the
Thread leg into cabinet
bottom frame rail.
For leveling, insert the shim
Use the tool provided to
underside of cabinet frame rail.
between the castor and frame rail. tighten the castor into place.
Lower Rail
Lower Rail Assembly
Assembly
Rail End
Rail End
Snug Fit
Here
Bearing
Race
Snug Fit
Here
Leveling Shim
5
Leg
Castor
The end of the leg is
adjustable to easy leveling.
6
6
Download from Www.Somanuals.com. All Manuals Search And Download.
True Food Service Equipment, Inc.
INSTALLATION / OPERATION INSTRUCTIONS
LEVELING
Step 4
D. Ensure that the drain hose or hoses are
positioned in the pan.
A. Set unit in its final location. Be sure there is
adequate ventilation in your room. Under extreme
heat conditions, (100°F+, 38°C+), you may want to
install an exhaust fan.
E. Free plug and cord from inside the lower rear of
the cooler (do not plug in).
F. The unit should be placed close enough to the
electrical supply so that extension cords are never
used.
Warning
Warranty is void if ventilation is insufficient.
Warning
B. Proper leveling of your True cooler is critical to
operating success (for non-mobile models). Effective
condensate removal and door operation will be
effected by leveling.
Compressor warranties are void if the unit is more
than 7 ft. (2.1m) from plug-in connection.
C. The cooler should be leveled front to back and
side to side with a level.
1 2 2 7 -5
7
7
Download from Www.Somanuals.com. All Manuals Search And Download.
True Food Service Equipment, Inc.
INSTALLATION / OPERATION INSTRUCTIONS
CONDUCTORS AND CIRCUITS
Wire Gauge for 2% Voltage Drop in Supply Circuits
115 Volt
Amps
Distance In Feet To Center of Load
20
14
14
14
14
14
30
14
14
14
14
14
40
14
14
14
14
14
50
14
14
14
14
14
60
14
14
14
14
14
70
14
14
14
14
14
80
14
14
14
14
12
90
14
14
14
12
12
100
14
14
14
12
12
120
14
14
12
12
10
140
14
14
12
10
10
160
14
12
12
10
10
2
3
4
5
6
7
8
9
10
12
14
14
14
14
14
14
14
14
14
14
14
14
14
14
12
14
14
12
12
12
14
12
12
12
10
12
12
12
10
10
12
12
10
10
10
12
10
10
10
8
10
10
10
10
8
10
10
8
8
8
10
8
8
8
8
8
8
8
8
6
14
16
18
20
25
14
14
14
14
12
14
12
12
12
10
12
12
10
10
10
10
10
10
10
8
10
10
8
8
8
10
8
8
8
6
8
8
8
8
6
8
8
8
6
6
8
8
8
6
6
6
6
8
6
5
6
6
8
5
4
6
6
5
5
4
30
35
40
45
50
12
10
10
10
10
10
10
8
8
8
8
8
8
6
6
8
6
6
6
6
6
6
6
6
5
6
6
5
5
4
6
5
5
4
4
6
5
4
4
3
5
4
4
3
3
4
4
3
3
2
4
3
2
2
1
3
2
2
1
1
Wire Gauge for 2% Voltage Drop in Supply Circuits
230 Volts
Amps
Distance In Feet To Center of Load
20
14
14
14
14
14
30
14
14
14
14
14
40
14
14
14
14
14
50
14
14
14
14
14
60
14
14
14
14
14
70
14
14
14
14
14
80
14
14
14
14
14
90
14
14
14
14
14
100
14
14
14
14
12
120
14
14
14
12
12
140
14
14
12
12
12
160
14
12
12
12
10
5
6
7
8
9
10
12
14
16
18
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
12
14
14
14
12
12
14
14
12
12
12
14
12
12
12
10
12
12
12
10
10
12
12
10
10
10
12
10
10
10
8
10
10
10
8
10
10
8
8
8
8
20
25
30
35
40
14
14
14
14
14
14
14
12
12
12
14
12
12
10
10
12
12
10
10
10
10
10
10
10
8
10
10
10
8
10
10
8
8
8
10
10
8
8
6
10
8
8
8
6
8
8
6
6
6
8
6
6
6
5
8
6
6
5
5
8
50
60
70
80
90
100
12
12
10
10
10
10
10
10
10
8
8
8
10
8
8
8
6
8
6
6
6
6
6
6
6
6
6
5
5
6
6
6
5
5
4
6
6
5
5
4
4
6
6
5
4
4
3
6
5
4
4
3
3
5
4
4
3
3
2
4
4
2
2
1
1
4
3
2
2
1
1
6
8
8
Download from Www.Somanuals.com. All Manuals Search And Download.
True Food Service Equipment, Inc.
INSTALLATION / OPERATION INSTRUCTIONS
ELECTRICAL INSTRUCTIONS
Step 5
True requires that a sole use circuit be dedicated
for the unit. Failure to do so voids warranty.
A. Before your new unit is connected to a power
supply, check the incoming voltage with a
WARNING
Compressor warranties are void if compressor burns
out due to low voltage.
voltmeter. If anything less than 100% of the rated
voltage for operation is noted, correct immediately.
WARNING
B. All units are equipped with a 7 ft. (2.1m) service
cord, and must be powered at proper operating
voltage at all times. Refer to cabinet data plate for
this voltage.
Power supply cord ground should not be removed!
NOTE
To reference wiring diagram - Remove front louvered
grill, wiring diagram is positioned on the inside cabinet
wall.
SEALING CABINET TO FLOOR
Step 1 - Position Cabinet
Step 6
Allow three inches between the wall and rear of the
GDM freezer for proper ventilation.
Raise and block the rear of the cabinet
Step 7
Apply sealant on floor as outline in Step 5. on other
three sides.
Step 2 - Level Cabinet
Cabinet should be level, side to side and front to
back. Place a carpenter’s level in the interior floor
in four places:
Step 8
Examine to see that cabinet is sealed to floor
around entire perimeter.
A. Position level in the inside floor of the unit near
the doors. (Level should be parallel to cabinet
front). Leve cabinet.
Note:
Asphalt floors are very susceptible to chemical
attack. A layer of tape on the floor prior to
applying the sealant will protect the floor.
B. Position level at the inside rear of cabinet.
(Again level should be placed parallel to cabinet
back).
NSF Approved Sealants:
C. Perform similar procedures to steps a & b by
placing the level on inside floor (left and right
sides - parallel to the depth of the cooler). Level
cabinet.
1. Minnesota Mining #EC800 Caulk
2. Minnesota Mining #EC2185 Caulk
3. Minnesota Mining #EC1055 Bead
4. Minnesota Mining #EC1202 Bead
5. Armstrong Cork - Rubber Caulk
6. Products Research Co. #5000 Rubber Caulk
7. G.E. Silicone Sealer
Step 3
Draw an outline on the base on the floor.
Step 4
Raise and block the front side of the cabinet.
8. Dow Corning Silicone Sealer
Step 5
Apply a bead of“NSF Approved Sealant”, (see list
below),To floor on half inch inside the outline
drawn. The bead must be heavy enough to seal the
entire cabinet surface when it is down on the
sealant.
9
9
Download from Www.Somanuals.com. All Manuals Search And Download.
True Food Service Equipment, Inc.
INSTALLATION / OPERATION INSTRUCTIONS
STARTUP
Step 6
NOTE
If the unit is disconnected or shut off, wait five
minutes before starting again.
A. The compressor is ready to operate. Plug in the
cooler.
B. Temperature control set at No. 4 position gives
freezers an approximate temperature of 20°F - 25°F.
Allow unit to function several hours, completely
cooling cabinet before changing the control setting.
RECOMMENDATION
Before loading product we recommend you run
your True unit empty for two to three days. This
allows you to be sure electrical wiring and
installation are correct and no shipping damage
has occurred. Remember, our factory warranty
does not cover product loss!
C. Excessive tampering with the control could lead
to service difficulties. Should it ever become
necessary to replace temperature control, be sure it
is ordered from your True dealer or recommended
service agent.
REPLACEMENT PARTS
TRUE maintains a record of the cabinet serial
number for your cooler. If at any time during the
life of your cooler, a part is needed, you may
obtain this part by furnishing the model number
and serial number to the company from whom
you purchased the cooler. Call Toll-Free: (800)-
424-TRUE (Direct to Parts Department). (800)-
325-6152 (U.S.A. & Canada only) or call: (636)-
240-2400.
D. Good air flow in your True unit is critical. Be
careful to load product so that it neither presses
against the back wall, nor comes within four inches
of the evaporator housing. Refrigerated air off the
coil must circulate down the back wall.
LIGHT SWITCH LOCATION:
GDIM models will have the light switch located on the
right side on the ceiling inside the unit. Most instances
the switch is located next to the temperature control.
10
10
Download from Www.Somanuals.com. All Manuals Search And Download.
True Food Service Equipment, Inc.
INSTALLATION / OPERATION INSTRUCTIONS
FREEZERS DEFROST TIME CLOCK
OPERATION (Grasslin Timer)
RECOMMENDED DEFROST
STEP 1
SETTINGS:
Your True freezer contains a defrost system
that is temperature terminated, however the
time clock has been designed with a time
termination back-up so that the defrost
period will not exceed thirty minutes.
While True requires a minimum 3 defrost
periods not to exceed 30 minutes the
procedure on this page should be followed
to customize your specific needs.
The white tabs located on the outmost area
of the time clock have been factory set for
(6:00 a.m., 2:00 p.m., and 10:00 p.m.).
Each tab represents 15 minutes of defrost
time. Notice that at each defrost time two
white tabs are set for 15 minutes each for a
total of 30 minutes of defrost.
True Manufacturing has factory set your
defrost time clock to a recommended time
and duration defrost scenario. All
refrigeration equipment operating below
30°F will accumulate frost on the
evaporator coil and will require routine
defrost. Your True equipment has been
designed for three defrost periods (6:00
a.m., 2:00 p.m. and 10:00 p.m.). If you
decide to deviate from these defrost time
STEP 2
Notice:
In order to program the time to begin the
defrost cycle, flip the white tabs out to set
the defrost time. To eliminate a defrost
time flip the white tabs back toward the
center of the Defrost Timer.
If timer is not set for a minimum of 3
defrost per day for 30 minutes each, the coil
may develop excessive frost. This may lead
to system failure and product loss, which is
not covered under warranty.
settings please follow the
for adjustment below.
procedures
REQUIRED TOOLS:
•
•
Phillips Screwdriver
1/4” Nut Driver or Socket
STEP 3
The following procedure may be
followed to customize your needs.
True recommends a 30 minute defrost cycle
three times per day.
Locating The Defrost Timer:
Take off louvered grill assembly by
removing four (4) corner screws.
High usage, high temperature, and
high humidity may require 4 defrost
settings per day.
Single Door Models:
WARNING:
Defrost timer is located in the lower right
corner behind the louvered grill (inside
galvanized electrical box).
Always follow the manufacturer’s
recommended settings when
programming the amount and duration
of the defrost cycles.
Two Door Models:
Defrost timer is located in the middle of the
cabinet, behind the louvered grill. Timer is
mounted to the left of the centered ballast
box (Inside of gray timer box).
Three Door Models:
Defrost timer is located on the left upright
post behind the louvered grill (Inside of
gray timer box).
Defrost Timer Box Image 1
Setting the timer:
(UNPLUG UNIT FROM
POWER SUPPLY!)
Outer most dial. White tabs represent 15
minutes of defrost time.
DO NOT SET THE TIME BY
ROTATING THE “OUTER” DIAL.
Turn the minute hand clockwise until the
time of day on the outer dial is aligned with
the triangle marker on the inner dial (two
o’clock position).
Time of day.
Inner most dial.
Adjusting The Defrost Timer:
(time initiated, time or temperature
terminated)
Defrost Timer Image 2
11
11
Download from Www.Somanuals.com. All Manuals Search And Download.
True Food Service Equipment, Inc.
MAINTENANCE, CARE & CLEANING
IF THE COMPRESSOR WILL
NOT RUN
1. If there is no voltage at the
compressor terminals, follow the wiring
diagram and check back from
compressor to the power supply to find
where the circuit is interrupted.
Make sure capacitors are discharged
before checking. Check for continuity
between each capacitor terminal and
the case. Continuity indicates a short,
and the capacitor should be replaced.
5. If the compressor has an external
protector, check for continuity through
the protector or protectors.
All external inherent protectors on
compressors can be replaced in the
field.
Substitute a “known to be good” start
capacitor if available. If compressor
then starts and runs properly, replace
the original start capacitor.
IF THE MOTOR COMPRESSOR
STARTS BUT TRIPS
REPEATEDLY ON THE
2. If power is available at the
compressor terminals, and the
compressor does not run, check the
voltage at the compressor terminals
while attempting to start the
compressor.
OVERLOAD PROTECTOR
1. Check the compressor suction and
discharge pressures while the
compressor is operating. Be sure the
pressures are within the limitations of
the compressor. If pressures are
excessive it may be necessary to clean
the condenser, purge air from the
system, replace crankcase pressure
regulating valve.
If a capacitor tester is not available, an
ohmmeter may be used to check run
and start capacitors for shorts or open
circuits. Use an ohmmeter set to its
highest resistance scale, and connect
prods to capacitor terminals.
If voltage at the compressor terminals
is below 90% of the nameplate voltage,
it is possible the motor may not
develop sufficient torque to start.
Check to determine if wire sizes are
adequate, electrical connections are
loose, the circuit is overloaded, or if the
power supply is inadequate.
a) With a good capacitor, the
indicator should first move zero, and
then gradually increase to infinity.
b) If there is no movement of the
ohmmeter indicator, an open circuit is
indicated.
An excessively low suction pressure
may indicate a loss of charge.
c) If the ohmmeter indicator
3. On single phase compressors, a
defective capacitor or relay may
prevent the compressor starting. If the
compressor attempts to start but is
unable to do so, or if there is a
humming sound, check the relay to see
if the relay contacts are damaged or
fused. The relay points should be
closed during the initial starting cycle,
but should open as the compressor
comes up to speed.
On units with no service gauge parts
where pressures can be checked, check
condenser to be sure it is clean and fan
is running. Excessive temperatures on
suction and discharge line may also
indicate abnormal operating conditions.
moves to zero, and remains there or on
a low resistance reading, a short circuit
is indicated. Defective capacitors
should be replaced.
4. If the correct voltage is available at
the compressor terminals, and no
2. Check the line voltage at the motor
terminals while the compressor is
operating. The voltage should be
within 10% of the nameplate voltage
rating. If outside those limits, the
voltage supply must be brought within
the proper range, or a motor
current is drawn, remove all wires from
the terminals and check for continuity
through the motor windings. On single
phase motor compressors, check for
continuity from terminals C to R, and C
to S. On compressors with line break
inherent protectors, an open overload
protector can cause a lack of continuity.
If the compressor is warm, wait one
hour for the compressor to cool and
recheck. If continuity cannot be
Remove the wires from the starting
relay and capacitors. Use a high
voltage ohmmeter to check for
continuity throughout the relay coil.
Replace the relay if there is not
continuity. Use an ohmmeter to check
across the relay contacts. Potential
relay contacts are normally closed
when the relay is not energized, current
relay contacts are normally open. If
either gives an incorrect reading,
replace the relay.
compressor with different electrical
characteristics must be used.
3. Check the amperage drawn while
the compressor is operating. Under
normal operating conditions, the
amperage drawn will seldom exceed
110% of the nameplate amperage.
High amperage can be caused by low
damage, defective running capacitors,
or a defective starting relay.
established through all motor windings,
the compressor should be replaced.
Check the motor for ground by means
of a continuity check between the
common terminal and the compressor
shell. If there is a ground, replace the
compressor.
Any capacitor found to be bulging,
leaking, or damaged should be
replaced.
12
Continued on next page
12
Download from Www.Somanuals.com. All Manuals Search And Download.
True Food Service Equipment, Inc.
MAINTENANCE, CARE & CLEANING
4. If all operating conditions are
normal, the voltage supply at the
compressor terminals balanced and
compartment in the top of the freezer.
This control is attached to the
evaporator drain pan.
3. Check the compressor discharge
pressure. An abnormally high
within limits, the compressor crankcase discharge pressure can cause a loss of
temperature within normal limits, and
the amperage drawn within the
specified range, the motor protector
may be defective, and should be
replaced.
capacity, and can be caused by a dirty
condenser, a malfunctioning condenser
fan, or air in the system.
3. Coil Defrost Heater
A. Lower the evaporator cover.
Disconnect the coil heater by removing
the wire nuts at the point where the
heater joins the electrical circuit of the
freezer in the evaporator compartment.
Check heater for continuity with an
ohmmeter. If the heater is defective,
cut the bale wires holding the heater to
the coil and remove the heater. Replace
with a new heater using bale wires
provided.
4. If the suction pressure is high, and
the evaporator and condenser are
functioning normally, check the
compressor amperage draw. An
amperage draw near or above the
nameplate rating indicates normal
compressor or unit may have damaged
valves.
If the operating conditions are normal
and the compressor is running
excessively hot for no observable
reason, or if the amperage drawn is
above the normal range and sufficient
to repeatedly trip the protector, the
compressor has internal damage and
should be replaced.
An amperage draw considerably below
the nameplate rating may indicate a
broken suction reed or broken
4. Drain Tube Heater
IF THE COMPRESSOR RUNS
BUT WILL NOT REFRIGERATE
A. Lower the evaporator cover.
Disconnect the drain tube heater by
removing the wire nuts at the point
where the heater joins the electrical
circuit of the freezer in the evaporator
compartment. Check the drain tube
heater with an ohmmeter.
connecting rod in the compressor.
1. Check the refrigerant charge.
Check the evaporator surface to
determine if it is evenly cold
throughout, or if partially starved. A
lack of charge may be indicated by
light, fluffy frost at the evaporator inlet.
Add refrigerant if necessary.
DIAGNOSIS AND
REPLACEMENT OF FREEZER
CABINET COMPONENTS
B. If the drain tube heater is
defective, disconnect the drain tube
from the rigid plastic drain, bend the
tabs that hold the evaporator drain pan
to the evaporator cover and raise the
drain pan so that the flexible heater is
visible, pull heater out of the plastic
drain tube and replace. Connect heater
to the electrical circuit in the evaporator
compartment.
1. Defrost Time Clock
A. Check timer motor to be sure
it runs.
2. Check the compressor suction
pressure. An abnormally low pressure
may indicate a loss of refrigerant
charge, a malfunctioning capillary tube,
a lack of evaporator capacity possibly
due to icing or low air flow, or a
restriction in the system.
B. Check contacts on the defrost
timer.
C. Check solenoid windings for
continuity to ensure contact
switching.
D. Check to be sure defrost
actuator pins are in proper
position.
E. Check all wires in the timer for
tightness to terminals and
broken wires.
5. Cabinet Temperature
Control
Often a restriction in a drier or strainer
can be identified by frost or a decrease
in temperature across the restriction due
to the pressure drop in the line. This
will be true only if liquid refrigerant is
in the line at the restricted point, since
any temperature change due to
restriction would be caused by the
flashing of liquid into vapor as the
pressure changes.
A. Remove the two screws on the
right side of the evaporator housing that
holds the control mounting plate.
Reach behind the evaporator housing
on the control side of the cabinet and
pull the control bulb out of the
receptacle in the roof of the cabinet.
Disconnect the wires from the control.
Check control for continuity, replace if
defective.
2. Defrost Control On The
Evaporator Drain Pan
A. If the defrost time is always 35
minutes (or whatever duration the
elapsed time adjustment is set at) and
the fan motors do not delay after a
defrost cycle and it has been
determined that the solenoid in the
defrost clock is functioning, change the
defrost control in the evaporator
Any abnormal restriction in the system
must be corrected.
13
13
Download from Www.Somanuals.com. All Manuals Search And Download.
True Food Service Equipment, Inc.
MAINTENANCE, CARE & CLEANING
MAINTENANCE, CARE & CLEANING
CLEANING THE CONDENSER COIL
When using electrical appliances, basic safety precautions should be followed, including the following:
REQUIRED TOOLS:
• Phillips Screwdriver
• Stiff Bristle Brush
• Adjustable Wrench
Step 1
Disconnect power to unit.
Step 2
Take off lower grill assembly by removing four
(4) corner screws.
Step 3
Remove bolts anchoring compressor assembly
to frame rails and carefully slide out. (tube
connections are flexible)
ꢀ
Step 4
ꢀ
ꢀ
Clean off accumulated dirt from the condenser coil
and the fan with a stiff bristle brush.
Step 5
After brushing the components off vacuum all dirt
residue from the coil, fan, and surrounding areas.
Step 6
Replace cardboard cover. Carefully slide
compressor assembly back into position and
replace bolts.
Step 7
1 2 2 7 -5
Reinstall louver assembly into unit with appropriate
fasteners and clips. Tighten all screws.
Step 8
Connect unit to power and check to see if
compressor is running.
14
14
Download from Www.Somanuals.com. All Manuals Search And Download.
True Food Service Equipment, Inc.
MAINTENANCE, CARE & CLEANING
IMPORTANT WARRANTY INFORMATION
Condensers accumulate dirt and require cleaning every 30 days. Dirty condensers result in
compressor failure, product loss, and lost sales... which are not covered by warranty.
If you keep the Condenser clean you will minimize your service expense and lower your electrical
costs. The Condenser requires scheduled cleaning every thirty days or as needed.
Air is pulled through the Condenser continuously, along with dust, lint, grease, etc.
A dirty Condenser can result in NON-WARRANTEED part & Compressor Failures, Product Loss, and
Lost Sales.
Proper cleaning involves removing dust from the Condenser. By using a soft brush, or vacuuming
the Condenser with a shop vac, or using CO2, nitrogen, or pressurized air.
If you cannot remove the dirt adequately, please call your refrigeration service company.
On most of the reach-in units the condenser is accessible in the rear of the unit. You must remove
the cabinet grill to expose the Condenser.
The Condenser looks like a group of vertical fins. You need to be able to see through the condenser
for the unit to function at maximum capacity. Do not place filter material in front of condensing coil.
This material blocks air-flow to the coil similar to having a dirty coil.
THE CLEANING OF THE CONDENSER IS NOT
Air
flow
COVERED BY THE WARRANTY!
HOW TO CLEAN THE CONDENSER:
1. Disconnect the electrical power to the unit.
2. Remove the louvered grill.
Condensing Unit
Condenser
3. Vacuum or brush the dirt, lint, or debris from the finned condenser coil.
4. If you have a significant dirt build up you can blow out the condenser with compressed air.
(CAUTION MUST BE USED to avoid eye injury. Eye protection is recommended.)
5. When finished be sure to replace the louvered grill. The grill protects the condenser.
6. Reconnect the electrical power to the unit.
If you have any questions, please call True Manufacturing at 636-240-2400 or 800-325-6152 and
ask for the Service Department. Service Department Availability Monday-Friday 7:30 a.m. to
5:30p.m. and Saturday 7:45 a.m. to 11:45 a.m. CST.
15
15
Download from Www.Somanuals.com. All Manuals Search And Download.
True Food Service Equipment, Inc.
MAINTENANCE, CARE & CLEANING
Stainless Steel Equipment Care and Cleaning
CAUTION: Do not use any steel wool, abrasive or chlorine based products to clean stainless
steel surfaces.
Stainless Steel Opponents
There are three basic things which can break down your stainless steel’s passivity layer and allow
corrosion to rear its ugly head.
1) Scratches from wire brushes, scrapers, and steel pads are just a few examples of items that can be
abrasive to stainless steel’s surface.
2) Deposits left on your stainless steel can leave spots. You may have hard or soft water depending on
what part of the country you live in. Hard water can leave spots. Hard water that is heated can
leave deposits if left to sit too long. These deposits can cause the passive layer to break down and
rust your stainless steel. All deposits left from food prep or service should be removed as soon as
possible.
3) Chlorides are present in table salt, food, and water. Household and industrial cleaners are the worst
type of chlorides to use.
8 steps that can help prevent rust on stainless steel:
1. Using the correct cleaning tools
Use non-abrasive tools when cleaning your stainless steel products. The stainless steel’s passive layer
will not be harmed by soft cloths and plastic scouring pads. Step 2 tells you how to find the
polishing marks.
2. Cleaning along the polish lines
Polishing lines or“grain”are visible on some stainless steels. Always scrub parallel to visible lines on
some stainless steels. Use a plastic scouring pad or soft cloth when you cannot see the grain.
3. Use alkaline, alkaline chlorinated or non-chloride containing cleaners
While many traditional cleaners are loaded with chlorides, the industry is providing an ever
increasing choice of non-chloride cleaners. If you are not sure of your cleaner’s chloride content
contact your cleaner supplier. If they tell you that your present cleaner contains chlorides, ask if
they have an alternative. Avoid cleaners containing quaternary salts as they can attack stainless steel,
causing pitting and rusting.
4. Water Treatment
To reduce deposits, soften the hard water when possible. Installation of certain filters can remove
corrosive and distasteful elements. Salts in a properly maintained water softener can be to your
advantage. Contact a treatment specialist if you are not sure of the proper water treatment.
5. Maintaining the cleanliness of your food equipment
Use cleaners at recommended strength (alkaline, alkaline chlorinated or non-chloride). Avoid
build-up of hard stains by cleaning frequently. When boiling water with your stainless steel
equipment, the single most likely cause of damage is chlorides in the water. Heating any cleaners
containing chlorides will have the same damaging effects.
6. Rinse
When using chlorinated cleaners you must rinse and wipe dry immediately. It is better to wipe
standing cleaning agents and water as soon as possible. Allow the stainless steel equipment to air
dry. Oxygen helps maintain the passivity film on stainless steel.
7. Hydrochloric acid (muriatic acid) should never be used on stainless steel
8. Regularly restore/passivate stainless steel
16
16
Download from Www.Somanuals.com. All Manuals Search And Download.
True Food Service Equipment, Inc.
MAINTENANCE, CARE & CLEANING
Stainless Steel Equipment Care and Cleaning
Recommended cleaners for certain situations / environments of
stainless steel
A) Soap, ammonia and detergent medallion applied with a cloth or sponge can be used for routine
cleaning.
B) Arcal 20, Lac-O-Nu Ecoshine applied provides barrier film for fingerprints and smears.
C) Cameo,Talc, Zud First Impression is applied by rubbing in the direction of the polished lines for
stubborn stains and discoloring.
D) Easy-off and De-Grease It oven aid are excellent for removals on all finishes for grease-fatty acids,
blood and burnt-on foods.
E) Any good commercial detergent can be applied with a sponge or cloth to remove grease and oil.
F) Benefit, Super Sheen, Sheila Shine are good for restoration / passivation.
NOTE:
The use of stainless steel cleaners or other such solvents is not
recommended on plastic parts. Warm soap and water will suffice.
LIGHT BULB REPLACEMENT
WARNING:
Disconnect power to cabinet before
replacing light bulbs.
IDL (INTEGRATED DOOR LIGHTING):
Squeeze the plastic lampshield together and pull
away from the door (See Image 1).
Push the bulb down while pulling the spring
activated lampholder up. This will give you
enough clearance to take the bulb out (See
Image 2).
1
IDL (Integrated Door Lighting)
2
IDL (Integrated Door Lighting)
17
17
Download from Www.Somanuals.com. All Manuals Search And Download.
TRUE REFRIGERATIONTM
True Food Service Equipment, Inc.
WARRANTY INFORMATION (U.S.A & CANADA ONLY!)
MADE IN
U.S.A.
SINCE 1945
ONE YEAR PARTS & LABOR WARRANTY
TRUE warrants to the original purchaser of every new TRUE refrigerated unit, the cabinet and all parts thereof, to be free from defects in material or
workmanship, under normal and proper use and maintenance service as specified by TRUE and upon proper installation and start-up in accordance with
the instruction packet supplied with each TRUE unit. TRUE’s obligation under this warranty is limited to a period of one (1) year from the date of original
installation or 15 months after shipment date from TRUE, whichever occurs first.
Any part covered under this warranty that are determined by TRUE to have been defective within one (1) year of original installation or fifteen (15)
months after shipment date from manufacturer, whichever occurs first, is limited to the repair or replacement, including labor charges, of defective parts or
assemblies. The labor warranty shall include standard straight time labor charges only and reasonable travel time, as determined by TRUE.
ADDITIONAL FOUR YEAR COMPRESSOR WARRANTY
In addition to the one (1) year warranty stated above, TRUE warrants its hermetically and semi-hermetically sealed compressor to be free from defects in
both material and workmanship under normal and proper use and maintenance service for a period of four (4) additional years from the date of original
installation but not to exceed five (5) years and three (3) months after shipment from the manufacturer.
Compressors determined by TRUE to have been defective within this extended time period will, at TRUE’s option, be either repaired or replaced with a
compressor or compressor parts of similar design and capacity.
The four (4) year extended compressor warranty applies only to hermetically and semi-hermetically sealed parts of the compressor and does not apply
to any other parts or components, including, but not limited to, cabinet, paint finish, temperature control, refrigerant, metering device, driers, motor starting
equipment, fan assembly or any other electrical component, etcetera.
404A/134A COMPRESSOR WARRANTY
The four year compressor warranty detailed above will be voided if the following procedure is not carefully adhered to:
1. This system contains R404A or R134A refrigerant and polyol ester lubricant. The polyol ester lubricant has rapid moisture absorbing qualities. If long
exposure to the ambient conditions occur, the lubricant must be removed and replaced with new. For oil amounts and specifications please call True
technical service department (800-325-6152). Failure to comply with recommended lubricant specification will void the compressor warranty.
2. Drier replacement is very important and must be changed when a system is opened for servicing. A drier using XH-7 desiccant or an exact
replacement solid core drier must be used. The new drier must also be the same capacity as the drier being replaced.
3. Micron level vacuums must be achieved to insure low moisture levels in the system. 500 microns or lower must be obtained.
WARRANTY CLAIMS
All claims for labor or parts must be made directly through TRUE. All claims should include: model number of the unit, the serial number of the cabinet,
proof of purchase, date of installation, and all pertinent information supporting the existence of the alleged defect.
In case of warranty compressor, the compressor model tag must be returned to TRUE along with above listed information.
Any action or breach of these warranty provisions must be commenced within one (1) year after that cause of action has occurred.
WHAT IS NOT COVERED BY THIS WARRANTY
TRUE’s sole obligation under this warranty is limited to either repair or replacement of parts, subject to the additional limitations below. This warranty
neither assumes nor authorizes any person to assume obligations other than those expressly covered by this warranty.
NO CONSEQUENTIAL DAMAGES. TRUE IS NOT RESPONSIBLE FOR ECONOMIC LOSS; PROFIT LOSS; OR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES,
INCLUDING WITHOUT LIMITATION, LOSSES OR DAMAGES ARISING FROM FOOD OR PRODUCT SPOILAGE CLAIMS WHETHER OR NOT ON ACCOUNT OF
REFRIGERATION FAILURE.
WARRANTY IS NOT TRANSFERABLE. This warranty is not assignable and applies only in favor of the original purchaser/user to whom delivered. ANY SUCH
ASSIGNMENT OR TRANSFER SHALL VOID THE WARRANTIES HEREIN MADE AND SHALL VOID ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
IMPROPER USAGE. TRUE ASSUMES NO LIABILITY FOR PARTS OR LABOR COVERAGE FOR COMPONENT FAILURE OR OTHER DAMAGES RESULTING FROM
IMPROPER USAGE OR INSTALLATION OR FAILURE TO CLEAN AND/OR MAINTAIN PRODUCT AS SET FORTH IN THE WARRANTY PACKET PROVIDED WITH THE UNIT.
ALTERATION, NEGLECT, ABUSE, MISUSE, ACCIDENT, DAMAGE DURING TRANSIT OR INSTALLATION, FIRE, FLOOD, ACTS OF GOD. TRUE is not responsible for the
repair or replacement of any parts that TRUE determines have been subjected after the date of manufacture to alteration, neglect, abuse, misuse,
accident, damage during transit or installation, fire, flood, or act of God.
IMPROPER ELECTRICAL CONNECTIONS. TRUE IS NOT RESPONSIBLE FOR THE REPAIR OR REPLACEMENT OF FAILED OR DAMAGED COMPONENTS RESULTING
FROM ELECTRICAL POWER FAILURE, THE USE OF EXTENSION CORDS, LOW VOLTAGE, OR VOLTAGE DROPS TO THE UNIT.
NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE: THERE ARE NO OTHER WARRANTIES, EXPRESSED, IMPLIED OR
STATUTORY, EXCEPT THE ONE (1) YEAR PARTS & LABOR WARRANTY AND THE ADDITIONAL FOUR (4) YEAR COMPRESSOR WARRANTY AS DESCRIBED ABOVE. THESE
WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, INCLUDING IMPLIED WARRANTY AND MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF.
OUTSIDE U.S.: This warranty does not apply to, and TRUE is not responsible for, any warranty claims made on products sold or used outside the United
States.
REMOTE CONDENSERS: True warrants the original purchaser of the remote cabinet one year parts and labor coverage for all cabinet parts thereof to be
free from defects in material or workmanship, under normal and proper use and maintenance service, as specified by True. This warranty is limited to the
cabinet only. True assumes no liability for remote condensing units.
18
18