True Manufacturing Company Freezer GDIM 26 User Manual

TRUE FOOD SERVICE EQUIPMENT, INC.  
2001 East Terra Lane • P.O. Box 970 • O’Fallon, Missouri 63366  
(636)-240-2400 • FAX (636)272-2408 • INT’L FAX (636)272-7546 • (800)325-6152  
Parts Department (800)424-TRUE • Parts Department FAX# (636)272-9471  
INSTALLATION MANUAL FOR GDIM  
(GLASS DOOR ICE MERCHANDISERS)  
TABLE OF CONTENTS  
Safety Information  
Safety Precautions  
Do’s and Don’ts  
1
2
3
4
4
Proper Disposal  
Connecting Electricity  
Adapter Plugs  
Installation / Operation Instructions  
Ownership  
5
Required Tools  
5
Uncrating  
5
Locating & Installation of Leg/Castors  
Leveling Cabinet  
6
7
Wire Gauge Chart  
8
Sealing Cabinet to Floor & Electrical Inst.  
Start-up and Light Switch Location  
Defrost Time Clock Operation (Grasslin)  
Field Troubleshooting  
9
GDIM-26  
10  
11  
12-13  
Maintenance, Care & Cleaning  
Cleaning Condenser Coil  
Cabinet Cleaning  
14-15  
16-17  
17  
Light Bulb Replacement  
GDIM-26NT  
Warranty (U.S.A. & Canada Only!)  
18  
*Spanish, German, French and Dutch versions included.  
CONGRATULATIONS!  
You have just purchased the finest commercial  
freezer available. You can expect many years of  
trouble-free operation.  
GDIM-49  
G D I M - G L A S S D O O R  
I C E M E R C H A N D I S E R S  
6/6/08-500 SB #897013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
True Food Service Equipment, Inc.  
SAFETY INFORMATION  
How to Maintain Your  
Freezer  
to Receive the Most Efficient and  
Successful Operation  
You have selected one of the finest commercial freezer units made. It is  
manufactured under strict quality controls with only the best quality materials  
available. Your TRUE freezer when properly maintained will give you many  
years of trouble-free service.  
WARNING!  
Use this appliance for its intended purpose as described in this Owner Manual.  
SAFETY PRECAUTIONS  
When using electrical appliances, basic safety precautions should be followed, including the following:  
This freezer must be properly installed and  
located in accordance with the Installation  
Instructions before it is used.  
NOTE: We strongly recommend that any  
servicing be preformed by a qualified  
individual.  
Do not allow children to climb, stand or hang  
on the shelves in the freezer. They could  
damage the freezer and seriously injure  
themselves.  
Unplug the freezer before cleaning and making  
repairs.  
Setting temperature controls to the 0 position  
does not remove power to the light circuit,  
perimeter heaters, or evaporator fans.  
Do not touch the cold surfaces in the freezer  
compartment when hands are damp or wet.  
Skin may stick to these extremely cold surfaces.  
Do not store or use gasoline or other flammable  
vapors and liquids in the vicinity of this or any  
other appliance.  
Keep fingers out of thepinch pointareas;  
clearances between the doors and between the  
doors and cabinet are necessarily small; be  
careful closing doors when children are in the  
area.  
1
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
True Food Service Equipment, Inc.  
SAFETY INFORMATION  
2
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
True Food Service Equipment, Inc.  
SAFETY INFORMATION  
DANGER!  
RISK OF CHILD ENTRAPMENT  
PROPER DISPOSAL OF THE REFRIGERATOR  
Child entrapment and suffocation are not problems  
of the past. Junked or abandoned refrigerators are  
still dangerous… even if they will sit forjust a few  
days.” If you are getting rid of your old refrigerator,  
please follow the instructions below to help  
prevent accidents.  
Refrigerant Disposal  
Your old refrigerator may have a cooling system  
that usesOzone Depleting chemicals. If you are  
throwing away your old refrigerator, make sure the  
refrigerant is removed for proper disposal by a  
qualified service technician. If you intentionally  
release any refrigerants you can be subject to  
fines and imprisonment under provisions of the  
environmental regulations.  
Before You Throw Away Your Old Refrigerator  
or Freezer:  
Take off the doors.  
Leave the shelves in place so that children may  
not easily climb inside.  
USE OF EXTENSION CORDS  
NEVER USE AN EXTENSION CORD! TRUE will not warranty any freezer that has been  
connected to an extension cord.  
3
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
True Food Service Equipment, Inc.  
SAFETY INFORMATION  
WARNING!  
HOW TO CONNECT ELECTRICITY  
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.  
For personal safety, this appliance must be properly grounded.  
The power cord of this appliance is equipped with  
a 3-prong (grounding) plug which mates with a  
standard 3-prong (grounding) wall outlet to  
minimize the possibility of electric shock hazard  
from this appliance.  
could cause a fire hazard from overheated wires.  
Never unplug your freezer by pulling on the power  
cord. Always grip plug firmly and pull straight out  
from the outlet.  
Repair or replace immediately all power cords that  
have become frayed or otherwise damaged. Do not  
use a cord that shows cracks or abrasion damage  
along its length or at either end.  
Have the wall outlet and circuit checked by a  
qualified electrician to make sure the outlet is  
properly grounded.  
If the outlet is a standard 2-prong outlet, it is your  
personal responsibility and obligation to have it  
replaced with the properly grounded 3-prong wall  
outlet.  
When removing the freezer away from the wall, be  
careful not to roll over or damage the power cord.  
The freezer should always be plugged into it’s own  
individual electrical circuit, which has a voltage  
rating that matches the rating plate.  
This provides the best performance and also  
prevents overloading building wiring circuits which  
USE OF ADAPTER PLUGS  
NEVER USE AN ADAPTER PLUG! Because of potential safety hazards under certain conditions, we  
strongly recommend against the use of an adapter plug.  
The incoming power source to the cabinet  
North America Use Only!  
including any adapters used must have the adequate  
power available and must be properly grounded.  
NEMA plugs  
TRUE uses these types of plugs.  
If you do not have the right outlet  
have a certified electrician install  
the correct power source.  
4
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
True Food Service Equipment, Inc.  
INSTALLATION / OPERATION INSTRUCTIONS  
INSTALLATION / OPERATION INSTRUCTIONS  
OWNERSHIP  
To insure that your unit works properly from the  
first day, it must be installed properly. We highly  
recommend a trained refrigeration mechanic and  
electrician install your True equipment. The cost  
of a professional installation is money well spent.  
Before you start to install your True unit, carefully  
inspect it for freight damage. If damage is  
discovered, immediately file a claim with the  
delivery freight carrier.  
True is not responsible for damage incurred  
during shipment.  
REQUIRED TOOLS  
Adjustable Wrench  
Phillips Head Screwdriver  
Level  
UNCRATING  
Step 1  
The following procedure is recommended for  
uncrating the unit:  
A. Remove the outer packaging, (cardboard and  
bubbles or styrofoam corners and clear plastic).  
Inspect for concealed damage.Again,  
immediately file a claim with the freight carrier  
if there is damage.  
1
2
B. Move your unit as close to the final location as  
possible before removing the wooden skid.  
C. Remove door bracket on swinging glass door  
models (see image 1-2).  
Note: Keys for coolers with door locks are located  
in warranty packets.  
REMOTE UNITS (This section applies to  
remotes only!)  
• Remote cabinets must be ordered as remote.  
We do not recommend converting for a standard  
self contained to remote system.  
• Contact True Technical Service for BTU  
requirements.  
• No wiring necessary between cabinet and  
condensing unit.  
• All remote cabinets must be hard wired.  
• No castors available.  
• All remote condensing units purchased from  
True are 208/230 volts single phase.  
• All remote cabinets come standard using 404A  
refrigerant.  
If you have any questions regarding this  
section, please call True at 1-(800)-325-6152.  
• All remote units come standard with expansion  
valve, liquid line solenoid, heated condensate  
pan, and defrost timer when applicable.  
5
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
True Food Service Equipment, Inc.  
INSTALLATION / OPERATION INSTRUCTIONS  
LOCATING  
Step 2  
C. Carefully upright cabinet.  
A. Carefully lay the unit on its back to remove skid.  
Place packing material behind cabinet as a cushion.  
When lifting unit remember to  
Removing  
skid from  
bottom of  
cabinet.  
leave the cabinet upright for 24 hours before  
plugging into power source.  
B. Remove skid by unscrewing all base rail anchor  
brackets. Place skid to the side.  
INSTALLATION OF LEGS AND CASTORS  
Important Safeguard for installation of leg/castor (Images 1-5 demonstrate procedure)  
side. (diagonally)  
Step 3  
Securing Castors and Legs  
To obtain maximum strength and stability of the  
B. Install the desired number of shims, making sure  
the slot of the shim is in contact with the threaded  
stem of the castor.  
unit, it is important that you make sure each castor  
is secure. Legs are hand-tightened securely against  
the lower rail assembly. The bearing race on the  
castor of the top edge of the leg must make firm  
contact with the rail.  
C. If more than one shim is used, turn the slot at a  
90° angle so they are not in line.  
D. Turn the bearing race clockwise to tighten and  
secure the castor by tightening the anchoring bolt  
with a 3/4 inch open-end wrench or the tool  
provided.  
Unit leveling  
Four leveling shims have been provided for  
leveling castored units positioned on uneven  
floors. Shims must be positioned between rail  
end and bearing race.  
CAUTION  
To avoid damage to lower rail assembly,  
slowly raise unit to upright position.  
Note: Open holes located on the cross members of the  
frame rail should be plugged before unit is in use.  
A. Turn the bearing race counter-clockwise until  
the cabinet is level. Level front to back and side to  
1
2
4
3
Thread castor into the  
Thread leg into cabinet  
bottom frame rail.  
For leveling, insert the shim  
Use the tool provided to  
underside of cabinet frame rail.  
between the castor and frame rail. tighten the castor into place.  
Lower Rail  
Lower Rail Assembly  
Assembly  
Rail End  
Rail End  
Snug Fit  
Here  
Bearing  
Race  
Snug Fit  
Here  
Leveling Shim  
5
Leg  
Castor  
The end of the leg is  
adjustable to easy leveling.  
6
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
True Food Service Equipment, Inc.  
INSTALLATION / OPERATION INSTRUCTIONS  
LEVELING  
Step 4  
D. Ensure that the drain hose or hoses are  
positioned in the pan.  
A. Set unit in its final location. Be sure there is  
adequate ventilation in your room. Under extreme  
heat conditions, (100°F+, 38°C+), you may want to  
install an exhaust fan.  
E. Free plug and cord from inside the lower rear of  
the cooler (do not plug in).  
F. The unit should be placed close enough to the  
electrical supply so that extension cords are never  
used.  
Warning  
Warranty is void if ventilation is insufficient.  
Warning  
B. Proper leveling of your True cooler is critical to  
operating success (for non-mobile models). Effective  
condensate removal and door operation will be  
effected by leveling.  
Compressor warranties are void if the unit is more  
than 7 ft. (2.1m) from plug-in connection.  
C. The cooler should be leveled front to back and  
side to side with a level.  
1 2 2 7 -5  
7
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
True Food Service Equipment, Inc.  
INSTALLATION / OPERATION INSTRUCTIONS  
CONDUCTORS AND CIRCUITS  
Wire Gauge for 2% Voltage Drop in Supply Circuits  
115 Volt  
Amps  
Distance In Feet To Center of Load  
20  
14  
14  
14  
14  
14  
30  
14  
14  
14  
14  
14  
40  
14  
14  
14  
14  
14  
50  
14  
14  
14  
14  
14  
60  
14  
14  
14  
14  
14  
70  
14  
14  
14  
14  
14  
80  
14  
14  
14  
14  
12  
90  
14  
14  
14  
12  
12  
100  
14  
14  
14  
12  
12  
120  
14  
14  
12  
12  
10  
140  
14  
14  
12  
10  
10  
160  
14  
12  
12  
10  
10  
2
3
4
5
6
7
8
9
10  
12  
14  
14  
14  
14  
14  
14  
14  
14  
14  
14  
14  
14  
14  
14  
12  
14  
14  
12  
12  
12  
14  
12  
12  
12  
10  
12  
12  
12  
10  
10  
12  
12  
10  
10  
10  
12  
10  
10  
10  
8
10  
10  
10  
10  
8
10  
10  
8
8
8
10  
8
8
8
8
8
8
8
8
6
14  
16  
18  
20  
25  
14  
14  
14  
14  
12  
14  
12  
12  
12  
10  
12  
12  
10  
10  
10  
10  
10  
10  
10  
8
10  
10  
8
8
8
10  
8
8
8
6
8
8
8
8
6
8
8
8
6
6
8
8
8
6
6
6
6
8
6
5
6
6
8
5
4
6
6
5
5
4
30  
35  
40  
45  
50  
12  
10  
10  
10  
10  
10  
10  
8
8
8
8
8
8
6
6
8
6
6
6
6
6
6
6
6
5
6
6
5
5
4
6
5
5
4
4
6
5
4
4
3
5
4
4
3
3
4
4
3
3
2
4
3
2
2
1
3
2
2
1
1
Wire Gauge for 2% Voltage Drop in Supply Circuits  
230 Volts  
Amps  
Distance In Feet To Center of Load  
20  
14  
14  
14  
14  
14  
30  
14  
14  
14  
14  
14  
40  
14  
14  
14  
14  
14  
50  
14  
14  
14  
14  
14  
60  
14  
14  
14  
14  
14  
70  
14  
14  
14  
14  
14  
80  
14  
14  
14  
14  
14  
90  
14  
14  
14  
14  
14  
100  
14  
14  
14  
14  
12  
120  
14  
14  
14  
12  
12  
140  
14  
14  
12  
12  
12  
160  
14  
12  
12  
12  
10  
5
6
7
8
9
10  
12  
14  
16  
18  
14  
14  
14  
14  
14  
14  
14  
14  
14  
14  
14  
14  
14  
14  
14  
14  
14  
14  
14  
12  
14  
14  
14  
12  
12  
14  
14  
12  
12  
12  
14  
12  
12  
12  
10  
12  
12  
12  
10  
10  
12  
12  
10  
10  
10  
12  
10  
10  
10  
8
10  
10  
10  
8
10  
10  
8
8
8
8
20  
25  
30  
35  
40  
14  
14  
14  
14  
14  
14  
14  
12  
12  
12  
14  
12  
12  
10  
10  
12  
12  
10  
10  
10  
10  
10  
10  
10  
8
10  
10  
10  
8
10  
10  
8
8
8
10  
10  
8
8
6
10  
8
8
8
6
8
8
6
6
6
8
6
6
6
5
8
6
6
5
5
8
50  
60  
70  
80  
90  
100  
12  
12  
10  
10  
10  
10  
10  
10  
10  
8
8
8
10  
8
8
8
6
8
6
6
6
6
6
6
6
6
6
5
5
6
6
6
5
5
4
6
6
5
5
4
4
6
6
5
4
4
3
6
5
4
4
3
3
5
4
4
3
3
2
4
4
2
2
1
1
4
3
2
2
1
1
6
8
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
True Food Service Equipment, Inc.  
INSTALLATION / OPERATION INSTRUCTIONS  
ELECTRICAL INSTRUCTIONS  
Step 5  
True requires that a sole use circuit be dedicated  
for the unit. Failure to do so voids warranty.  
A. Before your new unit is connected to a power  
supply, check the incoming voltage with a  
WARNING  
Compressor warranties are void if compressor burns  
out due to low voltage.  
voltmeter. If anything less than 100% of the rated  
voltage for operation is noted, correct immediately.  
WARNING  
B. All units are equipped with a 7 ft. (2.1m) service  
cord, and must be powered at proper operating  
voltage at all times. Refer to cabinet data plate for  
this voltage.  
Power supply cord ground should not be removed!  
NOTE  
To reference wiring diagram - Remove front louvered  
grill, wiring diagram is positioned on the inside cabinet  
wall.  
SEALING CABINET TO FLOOR  
Step 1 - Position Cabinet  
Step 6  
Allow three inches between the wall and rear of the  
GDM freezer for proper ventilation.  
Raise and block the rear of the cabinet  
Step 7  
Apply sealant on floor as outline in Step 5. on other  
three sides.  
Step 2 - Level Cabinet  
Cabinet should be level, side to side and front to  
back. Place a carpenter’s level in the interior floor  
in four places:  
Step 8  
Examine to see that cabinet is sealed to floor  
around entire perimeter.  
A. Position level in the inside floor of the unit near  
the doors. (Level should be parallel to cabinet  
front). Leve cabinet.  
Note:  
Asphalt floors are very susceptible to chemical  
attack. A layer of tape on the floor prior to  
applying the sealant will protect the floor.  
B. Position level at the inside rear of cabinet.  
(Again level should be placed parallel to cabinet  
back).  
NSF Approved Sealants:  
C. Perform similar procedures to steps a & b by  
placing the level on inside floor (left and right  
sides - parallel to the depth of the cooler). Level  
cabinet.  
1. Minnesota Mining #EC800 Caulk  
2. Minnesota Mining #EC2185 Caulk  
3. Minnesota Mining #EC1055 Bead  
4. Minnesota Mining #EC1202 Bead  
5. Armstrong Cork - Rubber Caulk  
6. Products Research Co. #5000 Rubber Caulk  
7. G.E. Silicone Sealer  
Step 3  
Draw an outline on the base on the floor.  
Step 4  
Raise and block the front side of the cabinet.  
8. Dow Corning Silicone Sealer  
Step 5  
Apply a bead ofNSF Approved Sealant”, (see list  
below),To floor on half inch inside the outline  
drawn. The bead must be heavy enough to seal the  
entire cabinet surface when it is down on the  
sealant.  
9
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
True Food Service Equipment, Inc.  
INSTALLATION / OPERATION INSTRUCTIONS  
STARTUP  
Step 6  
NOTE  
If the unit is disconnected or shut off, wait five  
minutes before starting again.  
A. The compressor is ready to operate. Plug in the  
cooler.  
B. Temperature control set at No. 4 position gives  
freezers an approximate temperature of 20°F - 25°F.  
Allow unit to function several hours, completely  
cooling cabinet before changing the control setting.  
RECOMMENDATION  
Before loading product we recommend you run  
your True unit empty for two to three days. This  
allows you to be sure electrical wiring and  
installation are correct and no shipping damage  
has occurred. Remember, our factory warranty  
does not cover product loss!  
C. Excessive tampering with the control could lead  
to service difficulties. Should it ever become  
necessary to replace temperature control, be sure it  
is ordered from your True dealer or recommended  
service agent.  
REPLACEMENT PARTS  
TRUE maintains a record of the cabinet serial  
number for your cooler. If at any time during the  
life of your cooler, a part is needed, you may  
obtain this part by furnishing the model number  
and serial number to the company from whom  
you purchased the cooler. Call Toll-Free: (800)-  
424-TRUE (Direct to Parts Department). (800)-  
325-6152 (U.S.A. & Canada only) or call: (636)-  
240-2400.  
D. Good air flow in your True unit is critical. Be  
careful to load product so that it neither presses  
against the back wall, nor comes within four inches  
of the evaporator housing. Refrigerated air off the  
coil must circulate down the back wall.  
LIGHT SWITCH LOCATION:  
GDIM models will have the light switch located on the  
right side on the ceiling inside the unit. Most instances  
the switch is located next to the temperature control.  
10  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
True Food Service Equipment, Inc.  
INSTALLATION / OPERATION INSTRUCTIONS  
FREEZERS DEFROST TIME CLOCK  
OPERATION (Grasslin Timer)  
RECOMMENDED DEFROST  
STEP 1  
SETTINGS:  
Your True freezer contains a defrost system  
that is temperature terminated, however the  
time clock has been designed with a time  
termination back-up so that the defrost  
period will not exceed thirty minutes.  
While True requires a minimum 3 defrost  
periods not to exceed 30 minutes the  
procedure on this page should be followed  
to customize your specific needs.  
The white tabs located on the outmost area  
of the time clock have been factory set for  
(6:00 a.m., 2:00 p.m., and 10:00 p.m.).  
Each tab represents 15 minutes of defrost  
time. Notice that at each defrost time two  
white tabs are set for 15 minutes each for a  
total of 30 minutes of defrost.  
True Manufacturing has factory set your  
defrost time clock to a recommended time  
and duration defrost scenario. All  
refrigeration equipment operating below  
30°F will accumulate frost on the  
evaporator coil and will require routine  
defrost. Your True equipment has been  
designed for three defrost periods (6:00  
a.m., 2:00 p.m. and 10:00 p.m.). If you  
decide to deviate from these defrost time  
STEP 2  
Notice:  
In order to program the time to begin the  
defrost cycle, flip the white tabs out to set  
the defrost time. To eliminate a defrost  
time flip the white tabs back toward the  
center of the Defrost Timer.  
If timer is not set for a minimum of 3  
defrost per day for 30 minutes each, the coil  
may develop excessive frost. This may lead  
to system failure and product loss, which is  
not covered under warranty.  
settings please follow the  
for adjustment below.  
procedures  
REQUIRED TOOLS:  
Phillips Screwdriver  
1/4” Nut Driver or Socket  
STEP 3  
The following procedure may be  
followed to customize your needs.  
True recommends a 30 minute defrost cycle  
three times per day.  
Locating The Defrost Timer:  
Take off louvered grill assembly by  
removing four (4) corner screws.  
High usage, high temperature, and  
high humidity may require 4 defrost  
settings per day.  
Single Door Models:  
WARNING:  
Defrost timer is located in the lower right  
corner behind the louvered grill (inside  
galvanized electrical box).  
Always follow the manufacturer’s  
recommended settings when  
programming the amount and duration  
of the defrost cycles.  
Two Door Models:  
Defrost timer is located in the middle of the  
cabinet, behind the louvered grill. Timer is  
mounted to the left of the centered ballast  
box (Inside of gray timer box).  
Three Door Models:  
Defrost timer is located on the left upright  
post behind the louvered grill (Inside of  
gray timer box).  
Defrost Timer Box Image 1  
Setting the timer:  
(UNPLUG UNIT FROM  
POWER SUPPLY!)  
Outer most dial. White tabs represent 15  
minutes of defrost time.  
DO NOT SET THE TIME BY  
ROTATING THE “OUTER” DIAL.  
Turn the minute hand clockwise until the  
time of day on the outer dial is aligned with  
the triangle marker on the inner dial (two  
o’clock position).  
Time of day.  
Inner most dial.  
Adjusting The Defrost Timer:  
(time initiated, time or temperature  
terminated)  
Defrost Timer Image 2  
11  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
True Food Service Equipment, Inc.  
MAINTENANCE, CARE & CLEANING  
IF THE COMPRESSOR WILL  
NOT RUN  
1. If there is no voltage at the  
compressor terminals, follow the wiring  
diagram and check back from  
compressor to the power supply to find  
where the circuit is interrupted.  
Make sure capacitors are discharged  
before checking. Check for continuity  
between each capacitor terminal and  
the case. Continuity indicates a short,  
and the capacitor should be replaced.  
5. If the compressor has an external  
protector, check for continuity through  
the protector or protectors.  
All external inherent protectors on  
compressors can be replaced in the  
field.  
Substitute a “known to be good” start  
capacitor if available. If compressor  
then starts and runs properly, replace  
the original start capacitor.  
IF THE MOTOR COMPRESSOR  
STARTS BUT TRIPS  
REPEATEDLY ON THE  
2. If power is available at the  
compressor terminals, and the  
compressor does not run, check the  
voltage at the compressor terminals  
while attempting to start the  
compressor.  
OVERLOAD PROTECTOR  
1. Check the compressor suction and  
discharge pressures while the  
compressor is operating. Be sure the  
pressures are within the limitations of  
the compressor. If pressures are  
excessive it may be necessary to clean  
the condenser, purge air from the  
system, replace crankcase pressure  
regulating valve.  
If a capacitor tester is not available, an  
ohmmeter may be used to check run  
and start capacitors for shorts or open  
circuits. Use an ohmmeter set to its  
highest resistance scale, and connect  
prods to capacitor terminals.  
If voltage at the compressor terminals  
is below 90% of the nameplate voltage,  
it is possible the motor may not  
develop sufficient torque to start.  
Check to determine if wire sizes are  
adequate, electrical connections are  
loose, the circuit is overloaded, or if the  
power supply is inadequate.  
a) With a good capacitor, the  
indicator should first move zero, and  
then gradually increase to infinity.  
b) If there is no movement of the  
ohmmeter indicator, an open circuit is  
indicated.  
An excessively low suction pressure  
may indicate a loss of charge.  
c) If the ohmmeter indicator  
3. On single phase compressors, a  
defective capacitor or relay may  
prevent the compressor starting. If the  
compressor attempts to start but is  
unable to do so, or if there is a  
humming sound, check the relay to see  
if the relay contacts are damaged or  
fused. The relay points should be  
closed during the initial starting cycle,  
but should open as the compressor  
comes up to speed.  
On units with no service gauge parts  
where pressures can be checked, check  
condenser to be sure it is clean and fan  
is running. Excessive temperatures on  
suction and discharge line may also  
indicate abnormal operating conditions.  
moves to zero, and remains there or on  
a low resistance reading, a short circuit  
is indicated. Defective capacitors  
should be replaced.  
4. If the correct voltage is available at  
the compressor terminals, and no  
2. Check the line voltage at the motor  
terminals while the compressor is  
operating. The voltage should be  
within 10% of the nameplate voltage  
rating. If outside those limits, the  
voltage supply must be brought within  
the proper range, or a motor  
current is drawn, remove all wires from  
the terminals and check for continuity  
through the motor windings. On single  
phase motor compressors, check for  
continuity from terminals C to R, and C  
to S. On compressors with line break  
inherent protectors, an open overload  
protector can cause a lack of continuity.  
If the compressor is warm, wait one  
hour for the compressor to cool and  
recheck. If continuity cannot be  
Remove the wires from the starting  
relay and capacitors. Use a high  
voltage ohmmeter to check for  
continuity throughout the relay coil.  
Replace the relay if there is not  
continuity. Use an ohmmeter to check  
across the relay contacts. Potential  
relay contacts are normally closed  
when the relay is not energized, current  
relay contacts are normally open. If  
either gives an incorrect reading,  
replace the relay.  
compressor with different electrical  
characteristics must be used.  
3. Check the amperage drawn while  
the compressor is operating. Under  
normal operating conditions, the  
amperage drawn will seldom exceed  
110% of the nameplate amperage.  
High amperage can be caused by low  
damage, defective running capacitors,  
or a defective starting relay.  
established through all motor windings,  
the compressor should be replaced.  
Check the motor for ground by means  
of a continuity check between the  
common terminal and the compressor  
shell. If there is a ground, replace the  
compressor.  
Any capacitor found to be bulging,  
leaking, or damaged should be  
replaced.  
12  
Continued on next page  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
True Food Service Equipment, Inc.  
MAINTENANCE, CARE & CLEANING  
4. If all operating conditions are  
normal, the voltage supply at the  
compressor terminals balanced and  
compartment in the top of the freezer.  
This control is attached to the  
evaporator drain pan.  
3. Check the compressor discharge  
pressure. An abnormally high  
within limits, the compressor crankcase discharge pressure can cause a loss of  
temperature within normal limits, and  
the amperage drawn within the  
specified range, the motor protector  
may be defective, and should be  
replaced.  
capacity, and can be caused by a dirty  
condenser, a malfunctioning condenser  
fan, or air in the system.  
3. Coil Defrost Heater  
A. Lower the evaporator cover.  
Disconnect the coil heater by removing  
the wire nuts at the point where the  
heater joins the electrical circuit of the  
freezer in the evaporator compartment.  
Check heater for continuity with an  
ohmmeter. If the heater is defective,  
cut the bale wires holding the heater to  
the coil and remove the heater. Replace  
with a new heater using bale wires  
provided.  
4. If the suction pressure is high, and  
the evaporator and condenser are  
functioning normally, check the  
compressor amperage draw. An  
amperage draw near or above the  
nameplate rating indicates normal  
compressor or unit may have damaged  
valves.  
If the operating conditions are normal  
and the compressor is running  
excessively hot for no observable  
reason, or if the amperage drawn is  
above the normal range and sufficient  
to repeatedly trip the protector, the  
compressor has internal damage and  
should be replaced.  
An amperage draw considerably below  
the nameplate rating may indicate a  
broken suction reed or broken  
4. Drain Tube Heater  
IF THE COMPRESSOR RUNS  
BUT WILL NOT REFRIGERATE  
A. Lower the evaporator cover.  
Disconnect the drain tube heater by  
removing the wire nuts at the point  
where the heater joins the electrical  
circuit of the freezer in the evaporator  
compartment. Check the drain tube  
heater with an ohmmeter.  
connecting rod in the compressor.  
1. Check the refrigerant charge.  
Check the evaporator surface to  
determine if it is evenly cold  
throughout, or if partially starved. A  
lack of charge may be indicated by  
light, fluffy frost at the evaporator inlet.  
Add refrigerant if necessary.  
DIAGNOSIS AND  
REPLACEMENT OF FREEZER  
CABINET COMPONENTS  
B. If the drain tube heater is  
defective, disconnect the drain tube  
from the rigid plastic drain, bend the  
tabs that hold the evaporator drain pan  
to the evaporator cover and raise the  
drain pan so that the flexible heater is  
visible, pull heater out of the plastic  
drain tube and replace. Connect heater  
to the electrical circuit in the evaporator  
compartment.  
1. Defrost Time Clock  
A. Check timer motor to be sure  
it runs.  
2. Check the compressor suction  
pressure. An abnormally low pressure  
may indicate a loss of refrigerant  
charge, a malfunctioning capillary tube,  
a lack of evaporator capacity possibly  
due to icing or low air flow, or a  
restriction in the system.  
B. Check contacts on the defrost  
timer.  
C. Check solenoid windings for  
continuity to ensure contact  
switching.  
D. Check to be sure defrost  
actuator pins are in proper  
position.  
E. Check all wires in the timer for  
tightness to terminals and  
broken wires.  
5. Cabinet Temperature  
Control  
Often a restriction in a drier or strainer  
can be identified by frost or a decrease  
in temperature across the restriction due  
to the pressure drop in the line. This  
will be true only if liquid refrigerant is  
in the line at the restricted point, since  
any temperature change due to  
restriction would be caused by the  
flashing of liquid into vapor as the  
pressure changes.  
A. Remove the two screws on the  
right side of the evaporator housing that  
holds the control mounting plate.  
Reach behind the evaporator housing  
on the control side of the cabinet and  
pull the control bulb out of the  
receptacle in the roof of the cabinet.  
Disconnect the wires from the control.  
Check control for continuity, replace if  
defective.  
2. Defrost Control On The  
Evaporator Drain Pan  
A. If the defrost time is always 35  
minutes (or whatever duration the  
elapsed time adjustment is set at) and  
the fan motors do not delay after a  
defrost cycle and it has been  
determined that the solenoid in the  
defrost clock is functioning, change the  
defrost control in the evaporator  
Any abnormal restriction in the system  
must be corrected.  
13  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
True Food Service Equipment, Inc.  
MAINTENANCE, CARE & CLEANING  
MAINTENANCE, CARE & CLEANING  
CLEANING THE CONDENSER COIL  
When using electrical appliances, basic safety precautions should be followed, including the following:  
REQUIRED TOOLS:  
• Phillips Screwdriver  
• Stiff Bristle Brush  
• Adjustable Wrench  
Step 1  
Disconnect power to unit.  
Step 2  
Take off lower grill assembly by removing four  
(4) corner screws.  
Step 3  
Remove bolts anchoring compressor assembly  
to frame rails and carefully slide out. (tube  
connections are flexible)  
Step 4  
Clean off accumulated dirt from the condenser coil  
and the fan with a stiff bristle brush.  
Step 5  
After brushing the components off vacuum all dirt  
residue from the coil, fan, and surrounding areas.  
Step 6  
Replace cardboard cover. Carefully slide  
compressor assembly back into position and  
replace bolts.  
Step 7  
1 2 2 7 -5  
Reinstall louver assembly into unit with appropriate  
fasteners and clips. Tighten all screws.  
Step 8  
Connect unit to power and check to see if  
compressor is running.  
14  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
True Food Service Equipment, Inc.  
MAINTENANCE, CARE & CLEANING  
IMPORTANT WARRANTY INFORMATION  
Condensers accumulate dirt and require cleaning every 30 days. Dirty condensers result in  
compressor failure, product loss, and lost sales... which are not covered by warranty.  
If you keep the Condenser clean you will minimize your service expense and lower your electrical  
costs. The Condenser requires scheduled cleaning every thirty days or as needed.  
Air is pulled through the Condenser continuously, along with dust, lint, grease, etc.  
A dirty Condenser can result in NON-WARRANTEED part & Compressor Failures, Product Loss, and  
Lost Sales.  
Proper cleaning involves removing dust from the Condenser. By using a soft brush, or vacuuming  
the Condenser with a shop vac, or using CO2, nitrogen, or pressurized air.  
If you cannot remove the dirt adequately, please call your refrigeration service company.  
On most of the reach-in units the condenser is accessible in the rear of the unit. You must remove  
the cabinet grill to expose the Condenser.  
The Condenser looks like a group of vertical fins. You need to be able to see through the condenser  
for the unit to function at maximum capacity. Do not place filter material in front of condensing coil.  
This material blocks air-flow to the coil similar to having a dirty coil.  
THE CLEANING OF THE CONDENSER IS NOT  
Air  
flow  
COVERED BY THE WARRANTY!  
HOW TO CLEAN THE CONDENSER:  
1. Disconnect the electrical power to the unit.  
2. Remove the louvered grill.  
Condensing Unit  
Condenser  
3. Vacuum or brush the dirt, lint, or debris from the finned condenser coil.  
4. If you have a significant dirt build up you can blow out the condenser with compressed air.  
(CAUTION MUST BE USED to avoid eye injury. Eye protection is recommended.)  
5. When finished be sure to replace the louvered grill. The grill protects the condenser.  
6. Reconnect the electrical power to the unit.  
If you have any questions, please call True Manufacturing at 636-240-2400 or 800-325-6152 and  
ask for the Service Department. Service Department Availability Monday-Friday 7:30 a.m. to  
5:30p.m. and Saturday 7:45 a.m. to 11:45 a.m. CST.  
15  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
True Food Service Equipment, Inc.  
MAINTENANCE, CARE & CLEANING  
Stainless Steel Equipment Care and Cleaning  
CAUTION: Do not use any steel wool, abrasive or chlorine based products to clean stainless  
steel surfaces.  
Stainless Steel Opponents  
There are three basic things which can break down your stainless steel’s passivity layer and allow  
corrosion to rear its ugly head.  
1) Scratches from wire brushes, scrapers, and steel pads are just a few examples of items that can be  
abrasive to stainless steel’s surface.  
2) Deposits left on your stainless steel can leave spots. You may have hard or soft water depending on  
what part of the country you live in. Hard water can leave spots. Hard water that is heated can  
leave deposits if left to sit too long. These deposits can cause the passive layer to break down and  
rust your stainless steel. All deposits left from food prep or service should be removed as soon as  
possible.  
3) Chlorides are present in table salt, food, and water. Household and industrial cleaners are the worst  
type of chlorides to use.  
8 steps that can help prevent rust on stainless steel:  
1. Using the correct cleaning tools  
Use non-abrasive tools when cleaning your stainless steel products. The stainless steel’s passive layer  
will not be harmed by soft cloths and plastic scouring pads. Step 2 tells you how to find the  
polishing marks.  
2. Cleaning along the polish lines  
Polishing lines orgrainare visible on some stainless steels. Always scrub parallel to visible lines on  
some stainless steels. Use a plastic scouring pad or soft cloth when you cannot see the grain.  
3. Use alkaline, alkaline chlorinated or non-chloride containing cleaners  
While many traditional cleaners are loaded with chlorides, the industry is providing an ever  
increasing choice of non-chloride cleaners. If you are not sure of your cleaner’s chloride content  
contact your cleaner supplier. If they tell you that your present cleaner contains chlorides, ask if  
they have an alternative. Avoid cleaners containing quaternary salts as they can attack stainless steel,  
causing pitting and rusting.  
4. Water Treatment  
To reduce deposits, soften the hard water when possible. Installation of certain filters can remove  
corrosive and distasteful elements. Salts in a properly maintained water softener can be to your  
advantage. Contact a treatment specialist if you are not sure of the proper water treatment.  
5. Maintaining the cleanliness of your food equipment  
Use cleaners at recommended strength (alkaline, alkaline chlorinated or non-chloride). Avoid  
build-up of hard stains by cleaning frequently. When boiling water with your stainless steel  
equipment, the single most likely cause of damage is chlorides in the water. Heating any cleaners  
containing chlorides will have the same damaging effects.  
6. Rinse  
When using chlorinated cleaners you must rinse and wipe dry immediately. It is better to wipe  
standing cleaning agents and water as soon as possible. Allow the stainless steel equipment to air  
dry. Oxygen helps maintain the passivity film on stainless steel.  
7. Hydrochloric acid (muriatic acid) should never be used on stainless steel  
8. Regularly restore/passivate stainless steel  
16  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
True Food Service Equipment, Inc.  
MAINTENANCE, CARE & CLEANING  
Stainless Steel Equipment Care and Cleaning  
Recommended cleaners for certain situations / environments of  
stainless steel  
A) Soap, ammonia and detergent medallion applied with a cloth or sponge can be used for routine  
cleaning.  
B) Arcal 20, Lac-O-Nu Ecoshine applied provides barrier film for fingerprints and smears.  
C) Cameo,Talc, Zud First Impression is applied by rubbing in the direction of the polished lines for  
stubborn stains and discoloring.  
D) Easy-off and De-Grease It oven aid are excellent for removals on all finishes for grease-fatty acids,  
blood and burnt-on foods.  
E) Any good commercial detergent can be applied with a sponge or cloth to remove grease and oil.  
F) Benefit, Super Sheen, Sheila Shine are good for restoration / passivation.  
NOTE:  
The use of stainless steel cleaners or other such solvents is not  
recommended on plastic parts. Warm soap and water will suffice.  
LIGHT BULB REPLACEMENT  
WARNING:  
Disconnect power to cabinet before  
replacing light bulbs.  
IDL (INTEGRATED DOOR LIGHTING):  
Squeeze the plastic lampshield together and pull  
away from the door (See Image 1).  
Push the bulb down while pulling the spring  
activated lampholder up. This will give you  
enough clearance to take the bulb out (See  
Image 2).  
1
IDL (Integrated Door Lighting)  
2
IDL (Integrated Door Lighting)  
17  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TRUE REFRIGERATIONTM  
True Food Service Equipment, Inc.  
WARRANTY INFORMATION (U.S.A & CANADA ONLY!)  
MADE IN  
U.S.A.  
SINCE 1945  
ONE YEAR PARTS & LABOR WARRANTY  
TRUE warrants to the original purchaser of every new TRUE refrigerated unit, the cabinet and all parts thereof, to be free from defects in material or  
workmanship, under normal and proper use and maintenance service as specified by TRUE and upon proper installation and start-up in accordance with  
the instruction packet supplied with each TRUE unit. TRUE’s obligation under this warranty is limited to a period of one (1) year from the date of original  
installation or 15 months after shipment date from TRUE, whichever occurs first.  
Any part covered under this warranty that are determined by TRUE to have been defective within one (1) year of original installation or fifteen (15)  
months after shipment date from manufacturer, whichever occurs first, is limited to the repair or replacement, including labor charges, of defective parts or  
assemblies. The labor warranty shall include standard straight time labor charges only and reasonable travel time, as determined by TRUE.  
ADDITIONAL FOUR YEAR COMPRESSOR WARRANTY  
In addition to the one (1) year warranty stated above, TRUE warrants its hermetically and semi-hermetically sealed compressor to be free from defects in  
both material and workmanship under normal and proper use and maintenance service for a period of four (4) additional years from the date of original  
installation but not to exceed five (5) years and three (3) months after shipment from the manufacturer.  
Compressors determined by TRUE to have been defective within this extended time period will, at TRUE’s option, be either repaired or replaced with a  
compressor or compressor parts of similar design and capacity.  
The four (4) year extended compressor warranty applies only to hermetically and semi-hermetically sealed parts of the compressor and does not apply  
to any other parts or components, including, but not limited to, cabinet, paint finish, temperature control, refrigerant, metering device, driers, motor starting  
equipment, fan assembly or any other electrical component, etcetera.  
404A/134A COMPRESSOR WARRANTY  
The four year compressor warranty detailed above will be voided if the following procedure is not carefully adhered to:  
1. This system contains R404A or R134A refrigerant and polyol ester lubricant. The polyol ester lubricant has rapid moisture absorbing qualities. If long  
exposure to the ambient conditions occur, the lubricant must be removed and replaced with new. For oil amounts and specifications please call True  
technical service department (800-325-6152). Failure to comply with recommended lubricant specification will void the compressor warranty.  
2. Drier replacement is very important and must be changed when a system is opened for servicing. A drier using XH-7 desiccant or an exact  
replacement solid core drier must be used. The new drier must also be the same capacity as the drier being replaced.  
3. Micron level vacuums must be achieved to insure low moisture levels in the system. 500 microns or lower must be obtained.  
WARRANTY CLAIMS  
All claims for labor or parts must be made directly through TRUE. All claims should include: model number of the unit, the serial number of the cabinet,  
proof of purchase, date of installation, and all pertinent information supporting the existence of the alleged defect.  
In case of warranty compressor, the compressor model tag must be returned to TRUE along with above listed information.  
Any action or breach of these warranty provisions must be commenced within one (1) year after that cause of action has occurred.  
WHAT IS NOT COVERED BY THIS WARRANTY  
TRUE’s sole obligation under this warranty is limited to either repair or replacement of parts, subject to the additional limitations below. This warranty  
neither assumes nor authorizes any person to assume obligations other than those expressly covered by this warranty.  
NO CONSEQUENTIAL DAMAGES. TRUE IS NOT RESPONSIBLE FOR ECONOMIC LOSS; PROFIT LOSS; OR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES,  
INCLUDING WITHOUT LIMITATION, LOSSES OR DAMAGES ARISING FROM FOOD OR PRODUCT SPOILAGE CLAIMS WHETHER OR NOT ON ACCOUNT OF  
REFRIGERATION FAILURE.  
WARRANTY IS NOT TRANSFERABLE. This warranty is not assignable and applies only in favor of the original purchaser/user to whom delivered. ANY SUCH  
ASSIGNMENT OR TRANSFER SHALL VOID THE WARRANTIES HEREIN MADE AND SHALL VOID ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY  
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  
IMPROPER USAGE. TRUE ASSUMES NO LIABILITY FOR PARTS OR LABOR COVERAGE FOR COMPONENT FAILURE OR OTHER DAMAGES RESULTING FROM  
IMPROPER USAGE OR INSTALLATION OR FAILURE TO CLEAN AND/OR MAINTAIN PRODUCT AS SET FORTH IN THE WARRANTY PACKET PROVIDED WITH THE UNIT.  
ALTERATION, NEGLECT, ABUSE, MISUSE, ACCIDENT, DAMAGE DURING TRANSIT OR INSTALLATION, FIRE, FLOOD, ACTS OF GOD. TRUE is not responsible for the  
repair or replacement of any parts that TRUE determines have been subjected after the date of manufacture to alteration, neglect, abuse, misuse,  
accident, damage during transit or installation, fire, flood, or act of God.  
IMPROPER ELECTRICAL CONNECTIONS. TRUE IS NOT RESPONSIBLE FOR THE REPAIR OR REPLACEMENT OF FAILED OR DAMAGED COMPONENTS RESULTING  
FROM ELECTRICAL POWER FAILURE, THE USE OF EXTENSION CORDS, LOW VOLTAGE, OR VOLTAGE DROPS TO THE UNIT.  
NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE: THERE ARE NO OTHER WARRANTIES, EXPRESSED, IMPLIED OR  
STATUTORY, EXCEPT THE ONE (1) YEAR PARTS & LABOR WARRANTY AND THE ADDITIONAL FOUR (4) YEAR COMPRESSOR WARRANTY AS DESCRIBED ABOVE. THESE  
WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, INCLUDING IMPLIED WARRANTY AND MERCHANTABILITY OR FITNESS FOR A PARTICULAR  
PURPOSE. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF.  
OUTSIDE U.S.: This warranty does not apply to, and TRUE is not responsible for, any warranty claims made on products sold or used outside the United  
States.  
REMOTE CONDENSERS: True warrants the original purchaser of the remote cabinet one year parts and labor coverage for all cabinet parts thereof to be  
free from defects in material or workmanship, under normal and proper use and maintenance service, as specified by True. This warranty is limited to the  
cabinet only. True assumes no liability for remote condensing units.  
18  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Tektronix Sander TDS 600C TDS 700D User Manual
Tektronix Welding System AWG5000 Series User Manual
Tokina Camera Accessories TM10Z0614GAI User Manual
TP Link Switch TL SF1016 User Manual
Traulsen Freezer RLT132WUT FHS User Manual
Triarch Indoor Furnishings 25931 User Manual
UNICOM Electric Network Card 100Base FX PCI User Manual
ViewSonic Projector S50 X50 User Manual
Weed Eater Blower 35879489 User Manual
Weed Eater Lawn Mower WE12538H User Manual