Models covered by this manual
This manual covers various energizer models:
1 J model
2 J model
3 J model
1000 / X1 / 401
2000 / X2 / 402
3000 / X3 / 403
Warning!
-
USA and Canada - To reduce the risk of electric
shock, the energizer’s power adaptor has a
polarised plug (one blade is wider than the other).
This plug will fit in a polarised outlet one way. If the
plug does not fit fully in the outlet, reverse the plug.
If it still does not fit, contact a qualified electrician
to install the proper outlet. Do not change the plug
in any way.
-
-
-
-
Switch the energizer off before installation or
performing any work on the fence.
Read all the safety considerations carefully. See
Check your installation to ensure that it complies
with all local safety regulations.
Do not connect simultaneously to a fence and to
any other device such as a cattle trainer or a poultry
trainer. Otherwise, lightning striking your fence will
be conducted to all other devices.
© 2006 Tru-Test Limited.
All product names and brand names in this document are trademarks or
registered trademarks of their respective holders.
No part of this publication may be photocopied, reproduced, stored in a
retrieval system, or transmitted in any form or by any means, electronic,
mechanical, photocopying, recording or otherwise without the prior written
permission of Tru-Test Limited. Product specifications may change without
prior notice.
-
Use only the mains/line power adaptor or battery
leads supplied with this energizer or a genuine
replacement part.
For more information about the Tru-Test range of quality products, see
Tru-Test Limited
25 Carbine Road
Mt Wellington
Auckland 1060
New Zealand
Postal address:
P O Box 51078
Pakuranga
Manukau 2140
New Zealand
Note:
-
This product has been designed for use with electric
animal fences.
810010 Issue 2 11/06
-
Keep this manual in a handy location.
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the energizer inside
Installing the energizer outside
The energizer must be installed inside when being
powered by the mains/line power supply.
The energizer may be installed outside, powered by a
battery.
Warning!
Warning! Do not power the energizer with the
mains/line power supply if it is being installed outside.
-
-
Do not use a mains/line power extension lead.
Allow 25 mm of clear space around the mains/line
power adaptor.
To install the energizer outside:
To install the energizer inside:
1
Select a suitable installation site. See Selecting a
1
Select a suitable installation site. See Selecting a
2
Hang the energizer on a fence wire or mount the
energizer on a post. Use the template printed on
the back cover of this manual, if required.
2
Mount the energizer on a wall. Use the template
printed on the back cover of this manual, if
required.
3
4
5
Connect the Fence earth terminal (green) to the
earthing system.
3
4
5
Connect the Fence earth terminal (green) to the
earthing system.
Connect the Fence output terminal (red) to the
fence.
Connect the Fence output terminal (red) to the
fence.
Connect the energizer to the battery using the
battery leads. Attach the + (red) clip to the positive
terminal of the battery, and the – (black) clip to its
negative terminal.
Connect the energizer to the mains/line power
using the mains/line power adaptor.
Note: If required, this energizer can be used as part of a
solar installation, by connecting it to a battery and solar
panel(s). For information about solar installations, refer to
the product's website (see packaging for details).
Note: If the energizer is being installed inside, it may be
powered by a battery instead of the mains/line power
supply, if required.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Select the pulse speed setting using the pulse speed switch.
Pulse speed switch
Setting
Description
Off
The energizer is off and is not operating.
Fast with
Battery Test
The energizer continues to operate at Fast speed (approximately 1.5 seconds between pulses),
explanation of the Indicator lights.
Slow
The energizer is operating at Slow speed (approximately 2.5 seconds between pulses).
Fast - Day
Slow - Night
The energizer is operating on Fast setting during the day and Slow setting at night. This setting
is for diurnal livestock and is a useful way of conserving battery power when a battery is being
used to power the energizer.
Slow - Day
Fast - Night
The energizer is operating on Slow setting during the day and Fast setting at night. This setting
is for nocturnal livestock and is a useful way of conserving battery power when a battery is
being used to power the energizer.
Fast
The energizer is operating at Fast speed (approximately 1.5 seconds between pulses).
Reading voltage
The Indicator lights show the voltage at the output terminals of the energizer.
When first connected to the power source, all the Indicator lights illuminate. They then illuminate separately from left to
right and back again. This indicates that the energizer is operating normally.
After three seconds, the energizer starts pulsing. Each Indicator light segment represents an increment of approximately
1 kV (1000 V) of output voltage. For example, if the first four Indicator light segments are illuminated at each pulse, the
output voltage is approximately 4 kV (4000 V).
Note: If five Indicator light segments are illuminated, the output voltage may be more than 5 kV (5000 V).
After about 20 seconds, the energizer ceases to display the output voltage and one Indicator light segment illuminates
each time the energizer pulses.
If you see only red lights at each pulse and no green lights, your fence line is very heavily loaded, and you will need to look
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Battery test setting
When the energizer is connected to a battery and the pulse speed switch is set to 'Fast with Battery Test' ( ) the
Indicator lights show the charge level of the battery. The battery test is only relevant when a lead-acid battery is used.
Lights
Battery-only installation
Excellent battery charge level (90-100%):
•
No action required.
Very good battery charge level (70-90%):
No action required.
Average battery charge level (40-70%):
•
•
•
Monitor battery charge level.
Recharge the battery to avoid long-term damage to the battery.
Poor battery charge level (20-40%):
•
•
Monitor battery charge level.
Recharge the battery to avoid long-term damage to the battery.
Very poor battery charge level (0-20%):
Recharge the battery immediately.
•
Battery selection and management
This section refers exclusively to rechargeable, lead-acid batteries, for example car, tractor, truck, marine or specialist
deep-cycle batteries.
The size of battery you select will depend on the model of energizer you have and the pulse speed switch position you use
most frequently. Refer to Operation on page 4 for an explanation of the function of the pulse speed switch.
Battery selection
As a guide, the amp hour (Ah) rating of the 12 V lead-acid battery required for each model is shown below. This table is
based on a 21 day operating period between battery charging. Although operating time can exceed 21 days, this is likely
to cause battery damage and will necessitate frequent replacement of the battery. For best system reliability and long term
battery life, the preferred battery and charging regime is to use a deep-cycle, lead-acid battery and to recharge it when it
has discharged to about half-way. For more information on testing battery charge level, see Battery test setting above.
Energizer Model
Pulse speed switch position
Current required
Battery capacity
1 J model
Fast
Slow
90 mA
55 mA
90 Ah
55 Ah
2 J model
3 J model
Fast
Slow
170 mA
105 mA
170 Ah
105 Ah
Fast
Slow
280 mA
170 mA
280 Ah
170 Ah
Warning! A rechargeable 12 V lead-acid battery must be used.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Battery safety
Battery management
•
Ensure that the battery is well ventilated when
recharging.
Warning! Batteries contain harmful chemicals and
when used incorrectly, may cause injury. Observe the
guidelines for battery care, maintenance and safety in
this manual and in the documentation supplied with
your battery.
•
•
Avoid temperatures greater than 50 °C (120 °F).
Ensure the battery is not exposed to naked flame or
sparks.
Building a permanent electric fence
Battery charging
Components of an electric fence
Warning!
An electric fence system comprises the following
elements:
-
Do not attempt to recharge a non-rechargeable
battery.
-
When recharging a battery, ensure that there is
adequate ventilation to allow gases to disperse.
•
•
An energizer.
An earth system. This comprises a number of metal
rods inserted into the ground, which are connected
to the Fence earth terminal on the energizer.
Regular recharging of the battery is essential. Use a
suitably rated battery charger and refer to the battery
manufacturer’s recommendations.
•
•
Insulated underground cables. Used to connect the
energizer to the earth and fence.
An insulated fence. Connected to the Fence output
terminal of the energizer. Fences can be made to a
variety of designs (see below).
1
2
Disconnect the battery from the energizer.
Attach the positive (+) battery charger lead to the
positive terminal of the battery, and the negative (–)
battery charger lead to the negative terminal on the
battery.
Other useful components that can be added:
Cut-out switches. Installed at regular
intervals, these allow you to isolate sections
of the fence for repair.
3
4
Insert the battery charger's input power plug into a
mains or line socket and turn on the power supply.
Lightning diverter kit. Used to minimise the
damage to your energizer from lightning
conducted down the fence line.
After the battery is charged, disconnect it from the
battery charger before connecting it to the
energizer.
Typical installation
Caution! Over-charging the battery will reduce its
life. Do not exceed the recommendations of the
battery manufacturer on recharging the battery from a
mains-powered (line-powered) source.
The animal receives a shock when it completes a circuit
between the fence and the earth system. The fence below
has all live wires and requires conductive soils. These
fences are often referred to as 'all-live' or 'earth-return'
fences.
Battery care and maintenance
•
House the battery in a suitably designed battery
box, if the battery is likely to be exposed to the
weather.
•
When not in use, keep the battery as fully charged
as possible.
•
•
Recharge a discharged battery as soon as possible.
Batteries should be stored fully charged and
recharged at regular intervals (every 8 weeks)
Alternative installation
•
•
Inspect the battery regularly to ensure that the
electrolyte level does not fall below 12 mm (½")
above the surface of the battery plates.
For poor conductivity soils (dry or sandy), a 'fence-return'
or 'earth-wire-return' system is recommended. On these
fences the Fence earth terminal is connected directly to at
least one of the fence wires. The animal gets maximum
shock from touching a live and earth wire at the same
time.
Fill using deionised, distilled or rain water. Do not
overfill. Refer to the battery manufacturer’s
recommendations for more information.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
15 m (49') spacing with droppers
Fence designs
Wild animals
7 wire, 10 m (33') spacing with droppers
Fences can be constructed to suit the type of livestock and
materials available. Discuss with your reseller which
design best suits your needs. Some suggested fence
configurations are below.
Cattle and horses
10-15 m (33-49') spacing, posts only
End assemblies
Angle stay
Suitable for field gate, high-tension strainer.
After firmly setting the footed strainer in the ground, dig
in the stay block just below ground level, at a distance to
ensure the angle stay will be held snugly in position. The
stay can be levered into position with a spade.
15-20 m (49-65') spacing with droppers
All-live system
Sheep, goats, cattle and horses
10 m (33') spacing, posts only
Earth-return system
7
Download from Www.Somanuals.com. All Manuals Search And Download.
4
5
Using a voltmeter, ensure that the fence voltage is
below 2 kV.
Horizontal stay
Suitable for field gate, high-tension strainer.
Check your earth system. Insert the voltmeter's
earth probe into the ground at the full extent of the
lead, and clip the other lead to the last earth rod.
The voltmeter should not read more than 0.3 kV.
Anything higher than this indicates that better
earthing is required. Either add more earth rods or
find a better ground area to drive in the earth rods.
Very simple to erect and most suitable as a high tension
strainer, excellent in areas where the soil gets very wet or
where heavy frost occurs.
Note: When earthing energizers located in dairies, earth
at least 20 m (65') away from the dairy using double-
insulated wire to avoid touching the dairy building or
equipment.
Installing and testing an earth system
Select a suitable site for the earth system. Sites need to
be:
•
At least 10 m (33') from other earth systems (e.g.
telephone, mains power or the earth system of
another energizer).
•
•
•
Away from stock or other traffic that could interfere
with the installation.
At a site that can be easily observed for
maintenance.
Temporary electric fencing
Ideally at a site that has damp soil (e.g. a shaded or
swampy location). Note that the earth does not
need to be directly adjacent to the energizer
installation.
A temporary fence can be quickly erected and easily
moved allowing the farmer to:
•
•
•
Make smaller paddocks (fields)
Keep herds of animals separated
Ration feed
Drive the required number of earth rods into the ground.
Use high-voltage, insulated cable and earth clamps to
continuously connect the earth rods and the energizer's
Fence earth terminal. Make sure the insulation is stripped
back to ensure good contact between the wire and the
earth rod. The table below specifies the minimum number
of 2 m (6'6") earth rods recommended for an earthing
system:
Note: Use more wires for smaller animals and wild
animals. Politape should be used when greater visibility is
required (e.g. horses).
An example of a temporary fence is shown below.
Energizer
1 J model
2 J model
3 J model
Earth rods
1
2
3
Test the earth system, using the following procedure:
1
2
Turn off the energizer.
At least 100 m (330') away from the energizer,
short circuit the fence by laying several steel rods or
lengths of pipe against the fence. For best results,
the fence voltage should be lowered to 2000 V or
less. In dry or sandy conditions, it may be necessary
to drive the rods up to 300 mm (12") into the earth.
Note: It is not acceptable to short-circuit a fence
return system to the earth wire of the fence.
3
Turn the energizer back on.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
This energizer is not intended for use by young children or
by infirm persons without supervision.
Safety considerations
Definition of special terms
Young children should be supervised to ensure that they
do not play with the energizer.
Energizer – An appliance that is intended to periodically
deliver voltage impulses to a fence connected to it.
Electric animal fence constructions that are likely to lead
to the entanglement of animals or persons shall be
avoided.
Fence – A barrier for animals or for the purpose of
security, comprising one or more conductors such as metal
wires, rods or rails.
An electric animal fence shall not be supplied from two
separate energizers or from independent fence circuits of
the same energizer.
Electric fence – A barrier which includes one or more
electric conductors, insulated from earth, to which electric
pulses are applied by an energizer.
For any two separate electric animal fences, each supplied
from a separate energizer independently timed, the
distance between the wires of the two electric animal
fences shall be at least 2.5 m (8'). If this gap is to be
closed, this shall be effected by means of electrically non-
conductive material or an isolated metal barrier.
Fence circuit – All conductive parts or components within
an energizer that are connected or are intended to be
connected, galvanically, to the output terminals.
Earth electrode – Metal structure that is driven into the
ground near an energizer and connected electrically to the
Fence earth terminal of the energizer, and that is
independent of other earthing arrangements.
Barbed wire or razor wire shall not be electrified by an
energizer.
A non-electrified fence incorporating barbed wire or razor
wire may be used to support one or more offset electrified
wires of an electric animal fence. The supporting devices
for the electrified wires shall be constructed so as to
ensure that these wires are positioned at a minimum
distance of 150 mm (6") from the vertical plane of the
non-electrified wires. The barbed wire and razor wire shall
be earthed at regular intervals.
Connecting lead – An electric conductor, used to connect
the energizer to the electric fence or the earth electrode.
Electric animal fence – An electric fence used to contain
animals within or exclude animals from a particular area.
Electric security fence – A fence used for security purposes
which comprises an electric fence and a physical barrier
electrically isolated from the electric fence.
Follow our recommendations regarding earthing. See
Physical barrier – A barrier not less than 1.5 m (5') high
intended to prevent inadvertent contact with the pulsed
conductors of the electric fence. Physical barriers are
typically constructed from vertical sheeting, rigid vertical
bars, rigid mesh, rods or chainwire mesh.
A distance of at least 10 m (33') shall be maintained
between the energizer earth electrode and any other
earthing system connected parts such as the power supply
system protective earth or the telecommunication system
earth.
Public access area – Any area where persons are
protected from inadvertent contact with pulsed
conductors by a physical barrier.
Connecting leads that are run inside buildings shall be
effectively insulated from the earthed structural parts of
the building. This may be achieved by using insulated high
voltage cable.
Pulsed conductors – Conductors which are subjected to
high voltage pulses by the energizer.
Secure area – The side of an electric security fence where
a person may come into contact with the electric fence,
without the protection of a physical barrier.
Connecting leads that are run underground shall be run in
conduit of insulating material or else insulated high
voltage cable shall be used. Care must be taken to avoid
damage to the connecting leads due to the effects of
animal hooves or vehicle wheels sinking into the ground.
Requirements for electric animal fences
Connecting leads shall not be installed in the same
conduit as the mains supply wiring, communication cables
or data cables.
Electric animal fences and their ancillary equipment shall
be installed, operated and maintained in a manner that
minimises danger to persons, animals or their
surroundings.
Connecting leads and electric animal fence wires shall not
cross above overhead power or communication lines.
Warning! Avoid contacting electric fence wires
especially with the head, neck or torso. Do not climb
over, through or under a multi-wire electric fence. Use
a gate or a specially designed crossing point.
Crossings with overhead power lines shall be avoided
wherever possible. If such a crossing cannot be avoided it
shall be made underneath the power line and as nearly as
possible at right angles to it.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
If connecting leads and electric animal fence wires are
installed near an overhead power line, the clearances shall
not be less than those shown in the table below.
Ensure that all mains-operated, ancillary equipment
connected to the electric animal fence circuit provides a
degree of isolation between the fence circuit and the
supply mains equivalent to that provided by the energizer.
Minimum clearances from power lines for electric animal
fences
Protection from the weather shall be provided for the
ancillary equipment unless this equipment is certified by
the manufacturer as being suitable for use outdoors, and
is of a type with a minimum degree of protection IPX4.
Power line voltage
≤1000 V
Clearance
3 m (10')
4 m (13')
8 m (27')
>1000 V to ≤33,000 V
>33,000 V
Frequently asked
If connecting leads and electric animal fence wires are
installed near an overhead power line, their height above
the ground shall not exceed 3 m (10'). This height applies
to either side of the orthogonal projection of the
outermost conductors of the power line on the ground
surface, for a distance of:
questions/Troubleshooting
What voltage is required to control animals?
4 kV is widely accepted as the recommended minimum
voltage to control animals. However, you also require a
well constructed fence system to ensure that animals
cannot push through electrified wires.
•
2 m (6'6") for power lines operating at a nominal
voltage not exceeding 1000 V.
•
15 m (50') for power lines operating at a nominal
voltage exceeding 1000 V.
The fence voltage is below 4 kV. How do I
increase the voltage?
Electric animal fences intended for deterring birds,
household pet containment or training animals such as
cows need only be supplied from low output energizers to
obtain satisfactory and safe performance.
Check the energizer. Disconnect the fence wire from the
energizer's fence output terminal. Measure the voltage
across the energizer terminals with a Fault Finder or
Digital Voltmeter. If the voltage is less than 6 kV, the
energizer may require servicing.
In electric animal fences intended for deterring birds from
roosting on buildings, no electric fence wire shall be
connected to the energizer earth electrode. A warning
sign shall be fitted to every point where persons may gain
ready access to the conductors.
Check the energizer earthing. Use the procedure described
Where an electric animal fence crosses a public pathway,
a non-electrified gate shall be incorporated in the electric
animal fence at that point or a crossing by means of stiles
shall be provided. At any such crossing, the adjacent
electrified wires shall carry warning signs.
Check the fence system for faults. The most common
source of low voltage is faults on the fence line.
If the fence, earth and energizer are in good condition and
the voltage is still below 4 kV, talk to your nearest
reseller. Recent extensions to your fence, a poor fence
layout, or soil conditions may be causing inadequate
voltage.
Any part of an electric animal fence that is installed along
a public road or pathway shall be identified at frequent
intervals by warning signs securely fastened to the fence
posts or firmly clamped to the fence wires.
How do I locate faults?
•
The size of the warning sign shall be at least
100x200 mm (4x8").
The recommended tool for locating faults is a Fault Finder.
This combined voltage and current meter allows you to
rapidly locate sources of current leakage. Alternatively,
use a Digital Voltmeter. Use cut-out switches to turn off
the power to different sections of the farm. If the voltage
on the fence increases when a section of the farm is
turned off, then investigate that section for possible faults.
•
The background colour of both sides of the warning
sign shall be yellow. The inscription on the sign
shall be black and shall be either:
There are no lights flashing on the energizer.
or the substance of "CAUTION: Electric animal
fence".
Check the power supply to ensure that the power is
switched on. Check the fence system for faults (see
above). Check the energizer (see above). If the energizer
still does not operate, it may require servicing.
•
The inscription shall be indelible, inscribed on both
sides of the warning sign and have a height of at
least 25 mm (1").
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Servicing
This energizer contains no user serviceable parts. It must be returned to an authorised service centre for repair. This
energizer uses Double Insulation, where two systems of insulation are provided instead of grounding. No equipment
grounding means is provided in the supply cord of a double-insulated energizer, nor should a means for equipment
grounding be added to the energizer. Servicing a double-insulated energizer requires extreme care and knowledge of the
system and should only be done by qualified service personnel. Replacement parts for a double-insulated energizer must
be identical to the parts they replace. A double-insulated energizer is marked with the words DOUBLE INSULATION or
DOUBLE INSULATED and/or the symbol below.
Product specifications
1 J model
2 J model
3 J model
Power supply
12 V battery,
110-120 V, 60 Hz (115 V models) or
220-240 V, 50 Hz (230 V models)
Power consumption using a power adaptor
2.0 W
3.2 W
4.8 W
Current consumption using a 12 V, lead-acid battery
Fast speed
Slow speed
95 mA
60 mA
180 mA
110 mA
290 mA
175 mA
Maximum output voltage
Maximum output energy
Stored energy
9.8 kV
11.0 kV
2 J at 300 Ω
2.7 J
11.4 kV
3 J at 200 Ω
4.5 J
1 J at 500 Ω
1.4 J
Warranty
This product is warranted against faulty material and workmanship for a period from the date of purchase. If a warranted
defect occurs, return this product with proof of purchase to the place of purchase. Details of warranty periods and other
Note:
-
No responsibility is accepted for any accident or damage caused subsequent to any tampering with or modification to
or misuse of this product, including (but not limited to) alterations made by anyone other than Tru-Test or its agents.
To the maximum extent permitted by law, this warranty is exclusive, personal to you and in lieu of all other
warranties, representations or conditions relating to this product (whether express or implied and whenever arising)
hether originating by statute, law, trade, custom or otherwise.
-
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
|