Traulsen Refrigerator RBC200 User Manual

Quality Refrigeration  
OWNER’S MANUAL  
Instructions for the installation, operation,  
and maintenance of Blast Chiller Models:  
RBC50 (50 lb. capacity undercounter model)  
RBC100 (100 lb. capacity reach-in model)  
RBC200 (200 lb. capacity roll-in model)  
RBC200RT (200 lb. capacity roll-thru model)  
RBC400 (400 lb. capacity roll-in model)  
RBC400RT (400 lb. capacity roll-thru model)  
This Traulsen unit is built to our highest quality standards. We build our refrigerators, freezers, blast  
chillers and heated cabinets this way as a matter of pride. This philosophy has made Traulsen the  
leader in commercial refrigeration since 1938. We thank you for your choice and confidence in  
Traulsen equipment and we know you will receive many years of utility from this equipment.  
All Traulsen units are placed on a permanent record file with the service department. In the event  
of any future questions you may have, please refer to the model and serial number found on the name  
tag affixed to the unit. Should you need service, however, call us on our toll free number, 800-825-  
8220 between 7:30 am and 4:30 pm CST, Monday thru Friday. It is our pleasure to help and assist  
you in every possible way.  
IMPORTANT WARRANTY NOTES  
RBC50 & RBC100 Owner/Operators  
Please Contact (800) 825-8220 ext. #6115 upon start-up to register your warranty  
RB200/RBC200RT & RBC400/RBC400RT Owner/Operators  
Please Contact (800) 825-8220 ext. #6112 after installation but before start-up in order to register  
your warranty and arrange for a mandatory free Installation Validation & Service Check  
(allow at least 72 hours from time of call for this to be performed)  
Contact your local Hobart/Traulsen sales representative to arrange for a free on-site  
demonstration (after warranty registration and/or installation validation)  
FORM NUMBER TR35850 REV. 4/07  
P/N 375-60217-00  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Blast Chiller Installation Checklist  
Model RBC50  
1)  
2)  
Insure proper clearances, no obstruction to either front louver for at least 24from cabinet face.  
Install all eight legs or casters, insuring that the unit is level for proper operation (see section III d.  
for more details).  
3)  
4)  
5)  
Install the control panel (see section III n. for more details). Before doing so be sure to perform a  
visual inspection of the control to insure that no connections have come loose during shipment.  
Plug both power cords into separate, dedicated 115 volt/20 amp outlets (see section III f. for more  
details).  
Insure that paper supply for both printers are properly installed and that the printers themselves are  
operational (see section IV c. for more details).  
Model RBC100  
1)  
Insure proper clearances, no obstruction to either front louver for at least 24from cabinet face, 6”  
along left side, 4along the right side, and 6behind the unit  
Install the legs or casters, insuring that the unit is level for proper operation (see section III d. for  
more details).  
2)  
3)  
4)  
Make condensate removal provisions (see section III h. for more details).  
Hardwire the cord to a dedicated 220/60/1 volt, 4 wire, 20 amp circuit (see section III g. for more  
details).  
5)  
Insure that paper supply for both printers are properly installed and that the printers themselves are  
operational (see section IV c. for more details).  
Models RBC200 & RBC200RT (same for models RBC400 & RBC400RT but please see section III e. for  
additional installation/assembly instructions)  
1)  
Insure proper clearances, no obstruction to either front louver for at least 12above the cabinet  
and 4along the right side (for the drain tube). Unit must be located on a level surface.  
Seal the unit to the floor (see section III l for more details).  
2)  
3)  
4)  
Install the door ramp(s), (see section III l. for more details).  
Make condensate removal provisions (see section III h. for more details). Note that two drain outlets  
are provided. Please insure that the unused drain line is properly plugged to prevent leaks.  
Plug the power cord into a dedicated 115 volt/20 amp outlets (see section III g. for more  
details).  
5)  
IMPORTANT NOTE  
In order to accomplish blast chilling, models RBC200 and RBC200RT require one, and models RBC400 and  
RBC400RT require two properly sized remote condensing units (see section III j. for more details). After this  
installation has been completed by a qualified refrigeration technician, please call Traulsen Service at (800)  
825-8220 in order to arrange for your free on-site installation validation.  
6)  
`
In order to properly charge the system, at the completion of installation  
this must be run in blastchill mode for at least 90-minutes. To do so...  
MAIN MENU AIR 35°F  
BY TEMP  
BY TIME  
08:05:01  
BY PROD  
1- Select: BY TIME from the main menu.  
2- Then select the default setting CHILL (default) or scroll up or down  
to select this mode.  
3- Next select the default cycle time 01:30 (1 hour & 30 minutes) or  
scroll up or down to select this time.  
4- Finish by selecting START to initiate the test cycle.  
MORE  
BY TIME  
TYPE: CHILL  
CYCLE TIME: 01:30↑  
START  
MAIN  
7)  
Insure that paper supply for both printers are properly installed and  
that the printers themselves are operational (see section IV d. for more  
details).  
BY TIME  
TYPE: CHILL  
CYCLE TIME: 01:30↑  
MAIN  
START  
GENERAL NOTE:  
In the event that the owners manual is not available, please visit  
BY TIME  
TYPE: CHILL  
CYCLE TIME: 01:30↑  
MAIN START  
-2-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Blast Chiller Quick Start Checklist  
Starting a Chill Cycle - All Models  
1)  
Load product into the blast chiller. Both full and partial loads are OK,  
but for best results evenly distribute product throughout the interior  
tray slides or roll-in rack.  
2)  
Insert a food probe into the top, bottom and middle level pans. The  
probe should be located in the center of the food pan, at about the  
halfway point of the product depth.  
3)  
4)  
Close the door.  
Press the EZ Start button.  
The Blast Chill Process - All Models  
1)  
2)  
3)  
While in a blast chill cycle, cold air is rapidly being circulated around  
the food pans in order to remove heat as rapidly as possible.  
Actual chill times will vary depending on many product related factors  
such as starting temperature, product density, cycle load, content, etc.  
To insure food safety, the probes constantly monitor product core  
temperature(s) throughout each chill cycle, as well as during any  
holding period afterwards. Reports available at the end of each chill  
cycle can then be used by the operator to confirm that both FDA  
critical control points were met in accordance with the current food  
code.  
Concluding a Chill Cycle - All Models  
1)  
Upon each probe reaching target temperature (37°F) an audible alarm  
will sound for 30-seconds, and the probe number on the control  
display will continuously flash DONE.”  
2)  
3)  
Press the button alongside the probe flashing DONEin order to  
conclude that probes batch.  
The control will now display the print menu.  
3a. Press BOTH to receive both record and label printouts  
3b. Press RECORD to receive only the record printout  
3c. Press LABEL to receive only the label printout  
3d. Press NONE if no printouts are desired.  
NOTE: After printing has completed for either the RECORD, LABEL or  
BOTH, the control will continue to display the print menu until NONE  
is selected. This allows for multiple copies of each to be printed as  
needed.  
4)  
5)  
Repeat for any remaining probes as they complete in turn. Pressing  
NONE after the final probe has completed returns the display to the  
MAIN MENU.  
Any probes used should be properly sanitized prior to use in another  
batch.  
For more details and/or to make use of other  
control features please refer to pages 12 - 23 of this manual.  
-3-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Basic Operating Guidelines  
Chilling Within HACCP Guidelines  
1)  
The current FDA Food Code allows much more time for safe chilling  
than 90-minutes. This actually requires two critical control points of:  
a) From 135°F to 70°F within two hours, then...  
b) From 70°F to below 41°F within four hours, for a total chill time  
from 135°F to below 41°F of no more than six hours.  
2)  
Total chill times can exceed six hours in duration and still be safe.  
This safety threshhold does not include:  
a) Any time needed for product to chill from any start temp down to  
135°F, or...  
b) Any time elapsed to chill to below 41°F.  
Loading  
1)  
To achieve quickest chill times product should be loaded into pans to  
a depth of no greater than 2.  
2)  
3)  
Products should always be loaded into the shallowest pan possible.  
Chilling of products of greater than 2depth is often possible within  
FDA guidelines. However please note that actual chill times are a  
function of: Start Temperature, Product Density, Product Depth, and  
Total Load.  
4)  
Chilling of products, such as whole cooked chickens or meatloaf can  
be accomplished. However these should be positioned inside the  
chiller to allow the air-flow to contact the greatest surface area of the  
product.  
Covering  
1) Product does not always need to be covered. However before doing so  
please consider the following potential scenarios...  
a) If large loads of especially hot product are chilled there is the  
potential to freeze the coil.  
b) Loads of uncovered product that require especially long chilling  
times may have the potential to experience surface drying.  
c) Loads that are left uncovered in the chiller for long periods after  
completion of a chill cycle may also experience surface drying of  
the product if left uncovered.  
d) Loads of especially liquid product, such as soup, are highly  
recommended to be covered in order to prevent accidental  
spillage.  
e) Some foods, such as rice and pasta, are particularly vulnerable  
to drying and so should always be covered.  
Use of Food Probes  
1)  
For most accurate results food probes should be used. These need to  
be properly placed in the center of the thickest part of the product to  
insure an accurate temperature reading.  
2)  
Some products are not suitable for use of food probes. These  
products...  
a) Should be chilled BY TIME.  
b) The correct chill time should be established by the operator based  
upon actual product testing.  
c) The end cycle temperature should be verified manually with an  
clean, accurate thermometer as soon as the pre-established chill  
time elapses.  
For details about using your Traulsen blast chiller within a  
cook/chill operation please refer to form number TR99999.  
-4-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
II. RECEIPT INSPECTION  
III. INSTALLATION (continued)  
III. d - INSTALLING LEGS OR CASTERS (contd):  
box(es), it should contain either four (4) legs or casters  
(RBC50 x 8 or RBC100 x 4 and four bolts for each caster).  
All Traulsen products are factory tested for performance  
and are free from defects when shipped. The utmost  
care has been taken in crating this product to protect  
against damage in transit. All interior fittings have been  
carefully secured and the legs or casters are boxed and  
strapped inside to prevent damage. Door keys will be  
attached to the handle with a nylon strip. The handle is  
protected by an easily removable nylon netting.  
WARNING: THE CABINET MUST BE BLOCKED AND  
STABLE BEFORE INSTALLING LEGS OR CASTERS.  
To install the legs or casters, first raise and block the  
unit a minimum of 7from the floor. For installing legs,  
thread the legs into the threaded holes on the bottom of  
the cabinet (see figure 1). Be certain that all legs are  
tightened securely. When the unit is set in its final posi-  
tion, it is important for proper operation that the unit be  
level. The legs are adjustable for this purpose, turn the  
bottom of the leg counter-clockwise to raise it, clock-  
wise to lower it. Level the unit from front to back as well  
as side to side in this manner, using a level placed in the  
bottom of the cabinet.  
You should carefully inspect your Traulsen unit for dam-  
age during delivery. If damage is detected, you should  
save all the crating materials and make note on the  
carriers Bill Of Lading describing this. A freight claim  
should be filed immediately. If damage is subsequently  
noted during or immediately after installation, contact  
the respective carrier and file a freight claim. Under no  
condition may a damaged unit be returned to Traulsen  
without first obtaining written permission (return autho-  
rization).  
Fig. 1  
III. INSTALLATION  
III. a - LOCATION:  
Select a proper location for your Traulsen unit, away from  
extreme heat or cold. Allow enough clearance between  
the unit and the side wall so that the door (s) may open  
a minimum of 90°.  
Fig. 2  
III. b - PACKAGING:  
Please note that Traulsen units are not designed to be  
moved while on legs. If the unit requires moving, a pal-  
let jack or forklift should be used to prevent damage.  
For installing casters, the casters are platetype, and  
require the use of four (4) bolts each to secure them  
firmly to the cabinet bottom at each corner (see figure  
2). The caster bolts are tightened using a 1/2socket  
wrench.  
All Traulsen units are shipped from the factory bolted to  
a sturdy wooden pallet and packaged in a durable card-  
board container. The carton is attached to the wooden  
skid with the use of large staples. These should first be  
removed to avoid scratching the unit when lifting off the  
crate.  
To remove the wooden pallet, first if at all possible, we  
suggest that the cabinet remain bolted to the pallet dur-  
ing all transportation to the point of final installation.  
The bolts can then be removed with a 3/4socket  
wrench. Avoid laying the unit on its front, side or back  
for removal of the pallet.  
II. e - ASSEMBLY OF MODELS RBC400 & RBC400RT:  
Double depth roll-in/roll-thru units are shipped as two  
separate components which must be attached together  
at the jobsite. To accomplish this, first, place the front  
and rear cabinets in close proximity to each other being  
careful to align the drain from the front of the rear unit  
to the drain of the front unit. It will be necessary to level  
both units together at this time.  
NOTE: Traulsen does not recommend laying the unit  
down on its front, side or back. However, if you must  
please be certain to allow the unit to remain in an up-  
right position afterwards for 24 hours before plugging it  
in so that the compressor oils and refrigerant may settle.  
Next, using two pipe clamps, pull the units together (see  
figure 3). Install the covers over the gap formed between  
the units From inside the cabinets, using the screws  
provided, install the breaker strips using the strip as a  
template.  
III. c - WIRING DIAGRAM:  
Refer to the wiring diagram for any service work per-  
formed on the unit. Should you require a wiring dia-  
gram, please contact Traulsen Service at (800) 825-8220,  
and provide the model and serial number of the unit in-  
volved.  
Fig. 3 - Using two pipe  
clamps, pull the two units  
together and using the  
screws provided. Align  
the breaker strips as a  
template for the screw  
pattern inside and  
III. d - INSTALLING LEGS OR CASTERS:  
6high stainless steel legs are supplied standard for  
models RBC50 and RBC100. Casters in lieu of legs are  
available as an optional accessory for the same mod-  
els. These are shipped from the factory packed inside a  
cardboard box which is strapped to one of the shelves  
(two boxes for model RBC50 which requires either eight  
legs or casters). Remove the nylon strap and open the  
outside the cabinet.  
-5-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
III. INSTALLATION (continued)  
6Clearance  
In Rear  
III. f - CORD & PLUG:  
All Traulsen Blast Chill models (except model RBC100  
which is supplied with a cord set but no plug) are supplied  
with a cord & plug attached (for models RBC200 and  
RBC200RT, the cord and plug supplied is for the self-con-  
tained maintenance compressor only, the 4HP remote con-  
densing unit requires a separate electrical connection of  
its own). It is shipped coiled at the top of the cabinet, se-  
cured by a nylon strip. For your safety and protection, all  
units supplied with a cord and plug include a special three-  
prong grounding plug on the service cord. Select only a  
certified electrical outlet with grounding plug for power  
source. NOTE: Do not under any circumstances, cut or  
remove the round grounding prong from the plug, or use  
an extension cord.  
Fig. 5  
III. g - ELECTRICAL REQUIREMENTS:  
Air  
Model RBC50 is normally provided with two (2) grounding  
type cords with plugs (NEMA 5-15P). Two (2) separate 115/  
60/1 volt, 20 amp, grounded circuits with receptacle must  
be provided by a certified electrician to assure proper op-  
eration of the equipment (see figure 43).  
Intake  
Fig. 4  
4”  
Clearance  
On Right  
115/60/1  
Outlet #1  
115/60/1  
Outlet #2  
6Clearance  
On Left  
Model RBC100 is normally provided with a grounding type  
cord without a plug. A dedicated 220/60/1 volt, 4 wire, 20  
amp grounded circuit with receptacle should be provided  
by a certified electrician to assure that the computerized  
control is not adversely affected by the operation of other  
equipment.  
12Clearance  
On Top  
Models RBC200/RBC200RT are normally provided with one  
(RBC400/RBC400RT are provided with two) grounded  
cordset (NEMA 5-20P). A dedicated 115/60/1 volt, 20 amp,  
grounded circuit should be provided by a certified  
electrician to assure that the computerized control is not  
adversely affected by the operation of other equipment.  
III. h - PROPER CLEARANCES:  
Model RBC50: Make certain that there are no obstructions  
in front of the louver panels on the left and right front sides  
of the unit. This will allow for sufficient air flow to the re-  
frigeration system and maintenance access.  
4Clearance  
In Rear  
Model RBC100: A minimum of 4clearance on the right  
side, 6on the left side and 6clearance in the rear (see  
figure 5). This will allow for sufficient air flow to the  
refrigeration system and maintenance access.  
Models RBC200/RBC200RT & RBC400/RBC400RT: Insure  
an overhead clearance of 12and a rear clearance of 4(see  
figure 6). This will allow for sufficient air flow to the  
refrigeration system and maintenance access.  
4Clearance On Right  
Side For Drain Tube  
Fig. 6  
-6-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
III. INSTALLATION (continued)  
III. j - REMOTE CONDENSING UNIT REQUIREMENTS:  
III. i - CONDENSATE REMOVAL:  
This section applies only to models RBC200/200RT and  
RBC400/400RT. A remote condensing unit, operating on  
R-404A refrigerant, is required for Blast Chill operation  
on these models. The remote condensing unit should  
be capable of providing 18,700 BTU/hr @ -10°F evapora-  
tor temperature in a 90°F ambient environment.  
All Traulsen Blast Chill models (except model RBC50)  
require the use of a floor drain or floor mounted electric  
condensate evaporator.  
Model RBC100 requires either a floor drain or the use of  
an optional bottom mounted electric condensate evapo-  
rative pan kit (BCACC-BMCE) for condensate removal.  
The standard drain port location is at the rear of the unit  
(see figure 7).  
4 HP air-cooled and 3 HP water-cooled remote condens-  
ing units are available from Traulsen as an optional ac-  
cessory. Increased capacity of the remote condensing  
unit and line sizing will depend on the length and layout  
of the connecting piping from the remote condensing  
unit to the Blast Chill unit. Proper line sizing should be  
defined by a qualified refrigeration engineer or techni-  
cian.  
Front  
Of Unit  
Evaporative  
Pan Kit  
III. k - REMOTE UNIT CUT-OUT SETTINGS:  
This section applies only to models RBC200/200RT and  
RBC400/400RTRT. The low pressure cut-out of the re-  
mote condensing unit should be adjusted to obtain an  
evaporator coil temperature NO LOWER THAN -15°F. If  
the length of the connecting piping is 40 feet or less, the  
condensing unit low pressure cut-out settings will be  
approximately 15 +/- 2 PSIG cut-out and 25+/- 3 PSIG  
cut-in.  
Front  
Of Unit  
Floor  
Drain  
III. l - SEALING ROLL-IN/ROLL-THRU UNITS:  
This section applies only to models RBC200/200RT and  
RBC400/400RTRT Roll-In and Roll-Thru cabinets set  
on the floor require the floor area to be flat and level. In  
addition, after the cabinet is set in place, sealant should  
be used around the perimeter of the base to comply with  
NSF International requirements. After sealing the unit,  
the enclosed ramp should then be installed.  
Fig. 7  
Models RBC200 and RBC200RT require either a floor  
drain or the use of an optional floor mounted electric  
condensate evaporative pan kit (BCACC-FMCE) for con-  
densate removal. Two drain ports are provided, located  
at the right side and rear of the unit. Plug the unused  
drain port with the male pipe thread plug supplied (see  
figure 8).  
III. m - ON/OFF SWITCH:  
The Traulsen Blast Chiller models are all equipped with  
a power ON/OFF switch intended to cut power to the  
control as needed. In the event of routine maintenance  
and/or service is needed, be certain to disconnect the  
electrical power to the machine and follow lockout/tagout  
Procedures.  
Front  
Of Unit  
This is located on top of models RBC100, RBC200,  
RBC200RT, RBC400 and RBC400RT behind the louver  
panel assembly. On model RBC50, this switch is located  
on the right side of the control tower.  
Pipe  
Thread  
Plug  
Evaporative  
Pan Kit  
Fig. 8  
NOTE: Local code should be consulted when plumbing  
to drain port.  
-7-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
III. INSTALLATION (continued)  
IV. CARE & MAINTENANCE  
III. n - INSTALLING RBC50 CONTROL PANEL:  
Model RBC50 is shipped with the control panel detached,  
and laid flat, taped to the cabinet top (see figure 9). This  
must be installed before use. To install:  
WARNING: DISCONNECT ELECTRICAL POWER  
SUPPLY BEFORE CLEANING ANY PARTS OF THE  
UNIT.  
IV. a - CLEANING THE CONDENSER:  
The most important thing you can do to insure a long,  
reliable service life for your Traulsen is to regularly  
clean the condenser coil. The self-contained condens-  
ing unit requires regularly scheduled cleaning to keep  
the finned condenser clean of lint and dust accumula-  
tion. Keeping the condenser clean allows the cabinet  
to operate more efficiently and use less energy.  
To clean the self-contained condenser, first discon-  
nect electrical power to the cabinet and lift up the front  
louver assembly. To lift this, remove the two screws  
located on both sides at the bottom of the louver as-  
sembly. Once the screws are removed, the panel can  
be pivoted upwards allowing full access to the front  
facing condenser (for model RBC50, remove the four  
Phillips head screws from the front louver panel, and  
lift-off). Vacuum or brush any dirt, lint or dust from  
the finned condenser coil, the compressor and other  
cooling system parts. If significant dirt is clogging  
the condenser fins, use compressed air to blow this  
clear. Lower louver assembly and replace screws to  
hold it in place. For care of the remote condensing  
unit(s) used for models RBC200 & RBC200RT, consult  
the manufacturers product literature.  
Fig. 9  
Remove the packing material and tape holding the con-  
trol to the top. Remove and retain the six (6) Phillips head  
screws attaching the control cover to the frame. Also, re-  
move and retain the 1/4- 20 x 1/2screws found in the  
cabinet top. Next, position the control frame over the hole  
in the unit top and attach using 1/2-20x1/2screws (see  
figure 10).  
IV. b - PRINTER SUPPLIES:  
Supplies to support the both standard SmartChill®  
control printers are available directly from our Parts  
Department, or from your local Hobart Sales and  
Service Office. In addition it may also be possible to  
obtain one of these locally. The record printer paper is  
standard thermal paper which is readily available at  
most office supply outlets. Specifications are 2-1/2"  
wide by 85" long:  
Traulsen P/N 400-60003-00  
Office Depot #302-224  
Staples #PMF-5233  
Fig. 10  
The label printer uses a special peel-off label stock,  
Traulsen part number 400-60004-00. Each roll contains  
225 labels.  
NOTE: Extreme care needs to be taken to insure that:  
a- all wires connecting the control cover to the RBC50 are  
not damaged in any way, nor mistakenly mounted between  
the cover and cabinet during installation, which could re-  
sult in a short circuit, or...  
IV. c - INSTALLING PRINTER PAPER:  
To load the record printer paper, place a roll on the roll  
shaft. Position the paper such that the paper feeds  
from the back of the roll. This allows the thermal sen-  
sitive side of the paper to be on the upper surface as it  
feeds through the printer. The ends of the roll shaft  
are installed in the two roll holders.  
b- that no connections are pulled off the control.  
NOTE: Ensure that grommet is firmly in place, aligning  
round hole in bottom of control housing with round hole  
in unit top.  
Inspect paper roll, label roll, and spindles from rear of con-  
trol panel before installing panel. Reattach the control  
cover to the frame using the six (6) Phillips head screws  
Gently pull the feed door down and slightly forward. It  
is located on the bottom of the printer and will open  
about 90 degrees. Feed the paper into the loading slot  
directly behind the door and push it up until the paper  
previously removed.  
-8-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IV. CARE & MAINTENANCE (contd)  
V. OTHER  
IV. c - INSTALLING PRINTER PAPER (contd):  
V. c - SERVICE INFORMATION (contd):  
extends about 1/4" in front of the printer. Then return the  
feed door to its original position. If the feed door is not  
closed, the printer will not operate. Labels are loaded in  
the same manner. The label printer is located to the right  
of the record printer as you look at the unit. After turning  
the unit on, the label printer will automatically orient itself  
for the next label.  
If after checking the above items and the unit is still  
not operating properly, please contact Traulsen (if  
under warranty) or an authorized Traulsen service  
agent. A complete list of authorized service agents  
was provided along with your Traulsen unit. If you  
cannot locate this, you may also obtain the name of a  
service agent from the Service/Contact page of our  
IV. d - CLEANING THE EXTERIOR:  
Exterior stainless steel should be cleaned with warm wa-  
ter, mild soap and a soft cloth. Apply with a dampened  
cloth and wipe in the direction of the metal grain.  
Avoid the use of strong detergents and gritty, abrasive  
cleaners as they may tend to mar and scratch the surface.  
Do NOT use cleansers containing chlorine, this may pro-  
mote corrosion of the stainless steel.  
If service is not satisfactory, please contact our in-  
house service department at:  
Traulsen  
4401 Blue Mound Road  
Fort Worth, TX 76106  
(800) 825-8220  
Care should also be taken to avoid splashing the unit with  
water, containing chlorinated cleansers, when mopping  
the floor around the unit. For stubborn odor spills, use  
baking soda and water (mixed to a 1 TBSP baking soda to  
1 pint water ratio).  
Traulsen reserves the right to change specifications  
or discontinue models without notice.  
V. d - DEMONSTRATIONS:  
Traulsen sales representatives perform in-service op-  
erational training for the end-user. Contact your local  
Traulsen Sales Representative (after completion of the  
service agency start-up, on required models) to arrange  
this.  
IV. e - CLEANING THE INTERIOR:  
For cleaning stainless steel interiors, the use of baking  
soda as described in section IV. bis recommended. Use  
on breaker strips as well as door gaskets. All interior fit-  
tings are removable without tools to facilitate cleaning. A  
defrost cycle is the ideal time for performing interior clean-  
ing. For more information on the care of stainless steel  
finishes, please refer to section XV.  
V. e - SMARTCHILL DATA COMMUNICATIONS KIT:  
Each Traulsen blast chiller is communications capable.  
To make use of the optional communications feature,  
please refer to section "X." of this manual.  
V. f - THE SERIAL TAG:  
V. OTHER  
The serial tag is a permanently affixed sticker on which  
is recorded vital electrical and refrigeration data about  
your Traulsen product, as well as the model and serial  
number. This tag is located inside the door on the right  
interior wall of the cabinet.  
V. a - RBC200/RT SERVICE AGENCY CHECK & START-UP:  
After installation and start-up of models RBC200 or  
RBC200RT, please contact the Service Department at  
(800) 825-8220 to arrange for a Mechanical Installation  
andOperationInspection,whichisrequiredbyTraulsen  
in order to validate the warranty. On-site inspection not  
required for models RBC50 and RBC100.  
READING THE SERIAL TAG  
Serial = The permanent ID# of your Traulsen  
Model = The model # of your Traulsen  
Volts = Voltage  
Hz = Cycle  
PH = Phase  
Total Current = Maximum amp draw  
Minimum Circuit = Minimum circuit ampacity  
Lights = Light wattage  
V. b - ON-SITE BLAST CHILL TRAINING:  
Traulsen offers the operator comprehensive one and two  
day, on-site training in the proper operation of your Blast  
Chiller. Contact your authorized Traulsen equipment  
dealer for pricing information.  
V. c - SERVICE INFORMATION:  
Before calling for service, please check the following:  
Heaters  
Refrigerant = Refrigerant type used  
Design Pressure = High & low side operating  
pressures and refrigerant charge  
Agency Labels = Designates agency listings  
Is the electrical cord plugged in?  
Is the fuse OK or circuit breaker on?  
Is the ON/OFF Power Switch in the ON position?  
-9-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VI. THE SMARTCHILL® CONTROL  
VI. a - THE SMARTCHILL CONTROL - OVERVIEW:  
VI. d - START-UP:  
This unit is equipped with our exclusive SmartChill®  
microprocessor control (Traulsen Blast Chill units  
manufactured prior to 6/03 were equipped with the  
DIGITRAUL II control, please refer to owner's manual  
part number 375-60180-00 for more information).  
When power is turned ON to the blast chiller the start-  
up screen below appears.  
SmartChill  
RBC100  
VERSION X.XX  
MAIN MENU  
BY TEMP  
AIR 41°F  
BY PROD  
VI. e - OVER TEMPERATURE:  
BY TIME  
EZ START  
MORE  
An OVER TEMPERATURE situation occurs if interior  
cabinet air temperature rises to 160°F or above. The  
unit will shut down and a service technician should be  
notified.  
08:05:01  
®
The SmartChill Controller  
VI. f - IN THE EVENT OF A POWER INTERRUPTION:  
Following a power interruption, the system resumes  
at the previous activity. A report will also be printed  
containing the time of the power loss and the time of  
power return.  
The SmartChill® controller provides the ability to:  
Select the chill mode: By Product, By Time or By  
Temperature (chill or freeze)  
Display the current air and product temperatures  
and time.  
Monitor product temperatures with three smart  
probes to reduce chances of freezing.  
Select Soft Chill to reduce the chances of  
freezing in the final phase of chilling.  
Provide service diagnostics to quickly check  
machine functions and control circuitry.  
Send Chill® Cycle data via an RS232 port to  
SmartChill® computer software, providing state  
of the art HACCP data management.  
VI. g - GETTING STARTED:  
The Traulsen Blast Chiller is designed to chill its  
respective capacity of hot product from 135°F down to  
40°F in approximately 90 minutes if loaded in pans no  
more than 2” deep. However, it is important to follow  
all the preceding guidelines for product loading and  
batching in order to duplicate this performance  
on-site.  
Once you have insured that product is properly loaded  
into the pans and batched correctly, proceed to the  
nextsectioninordertocorrectlyoperatetheSmartChill  
controls chill feature modes.  
VI. b - PRINTING CAPABILITY:  
The standard printer provides the ability to:  
Print data from the last chill cycle with time,  
date, and temperature information.  
Charts chill temperatures vs. time at intervals  
that can be set by the supervisor.  
VI. h - EZ START FEATURE:  
All Traulsen Blast Chillers built after June 1, 2006  
include an EZ-Startfeature which allows a blast  
chill batch to be initiated with the touch of a single  
button located on the main menu.  
The label printer can print a condensed "LABEL" type  
of report with both PRODUCT and USER information.  
VI. c - CONTROL BASICS:  
Please note that in order to use this feature, one or  
more of the food probes must first be placed into hot  
product which is at least 40°F warmer than the interior  
cabinet temperature  
Begin by choosing a selection from the menu that  
appears on the control's display by pressing the button  
graphically connected to the display prompt. Four  
buttons are arranged on the left and four on the right.  
For example, to select BY TEMP, press the second  
button on the left.  
When using this feature the factory preset chill cycle  
parameters are: Blast Chill, By Temperature, with a  
product end-point of 37°F, and are not adjustable by  
the operator.  
-10-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VII. OPERATING THE BLAST CHILL CONTROL - STARTING A CHILL CYCLE  
VII. a - STARTING A CHILL CYCLE - BY TEMP:  
Use of the chilling mode BY TEMPERATURE means that product will be  
constantly chilled until the food probe(s) temperature reaches the preset  
target temperature, at which time the cycle is complete and operation reverts  
to normal refrigerated holding mode.  
MAIN MENU AIR 35°F  
BY TEMP  
BY TIME  
08:05:01  
BY PROD  
MORE  
Main Menu Display  
The main menu should be displayed on the control. To begin a chill cycle BY  
TEMPERATURE follow the below instructions:  
MAIN MENU AIR 35°F  
STEP ONE:  
Press the button to the left of where BY TEMPERATURE is  
shown on the display. The menu will then change to show TYPE  
: CHILL.  
BY TEMP  
BY TIME  
08:05:01  
BY PROD  
MORE  
STEP TWO: Select the TYPE by pressing the button to the left of where by  
TYPE is shown on the display. The display will change between  
CHILL (blast chill mode), SOFT (soft chill mode) and FREEZE  
(freeze chill mode).  
BY TEMPERATURE  
TYPE: CHILL  
TARGET TEMP: 37°F↑  
MAIN  
START  
BY TEMPERATURE  
TYPE: CHILL  
TARGET TEMP: 0°F↑  
STEP THREE: Adjust the TARGET TEMPERATURE if you wish to deviate from  
the factory preset temperatures (see chart below). This is  
done by pressing the buttons to the left and right of the UP and  
DOWN arrows.  
MAIN  
START  
FACTORY PRESET  
TARGET RANGE  
MODELS  
BY TEMP  
RANGE  
All Models Blast Chill  
All Models Soft Chill*  
All Models Freeze*  
37°F  
37°F  
0°F  
33-40°F  
33-40°F  
-22-28°F  
*Soft Chill and Freeze modes are not available on GC units.  
STEP FOUR: Insert the food probes into the food product as shown in  
section VI. a.  
NOTE: The SmartProbes sense the product temperature and are automatically selected (if product temperature  
is 75°F or higher). If probes are not sensed, probes have to be enabled using the SELECT PROBE menu.  
STEP FIVE:  
Close the door. You are now ready to begin chilling. If you are  
satisfied with the selections made in steps 1 thru 3, press the  
button to the right of where START is shown on the display. The  
chill time will display in the lower left corner of the display: Hr:  
Min: Sec: (hours:minutes:seconds).  
BY TEMPERATURE  
TYPE: CHILL  
TARGET TEMP: 37°F↑  
MAIN  
START  
BY TEMPERATURE  
TYPE: CHILL  
TARGET TEMP: 37°F↑  
NOTE: You can return to the MAIN MENU at any time by pushing the button to  
the left of where MAIN is shown on the display.  
MAIN  
START  
When a programmed batch has reached completion the alarm will activate,  
providing an audible notification (buzzer). This can be turned OFF by pressing  
the button to the right of where MUTE is shown on the display.  
(This step is repeated as each probe reaches the target temperatures; see page 14).  
CHILLING AIR: 14°F  
1 41°F  
2 44°F  
1:16:01  
DONE 3  
NOTE: After completion of all batches the unit will return to normal refrigerated  
holding temperatures (37°F). Product which was either BLAST or SOFT  
chilled may remain in the blast chiller. However, if a FREEZE CHILL cycle was  
completed product must be removed immediately upon batch completion.  
MUTE  
-11-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VII. OPERATING THE BLAST CHILL CONTROL - STARTING A CHILL CYCLE  
VII. a - STARTING A CHILL CYCLE - BY TEMP (contd):  
HOLDING  
1 DONE  
2 DONE  
AIR 37°F  
DONE 3  
STEP SIX:  
Select the doneprobe(s) by pressing the button(s) to the left  
or right of where that number probe(s) is displayed. Remove  
all product associated with the doneprobe(s) from the  
chiller. If all probes have completed their respective batches,  
the display changes to the HOLDING screen menu.  
1:16:01 ADD/REMOVE  
CHILLING  
1 41°F  
AIR 14°F  
DONE 3  
2 44°F  
1:16:08  
CONTINUE  
To remove a product before it is completed press the button to  
the right of where ADD/REMOVE is shown on the display.Select  
any other probes number to stop cycle and remove it. Answer,  
by pressing the button to the left/right of where NO/YES is  
shown on the display.  
SELECT PROBE:  
1 39°F  
2 44°F  
1:16:28  
REMOVE 3  
CONTINUE  
STEP SEVEN: The display will ask if you want to print a chill cycle data report  
and/or label for that particular probe.  
STOP CYCLE ON #2  
REMOVE PRODUCT?  
NO  
1) RECORD = Print probe report on standard printer only  
2) LABEL = Print probe report on label printer only  
3) BOTH = Print probe report on both standard and label  
printers.  
YES  
PRINT PROBE #  
RECORD  
LABEL  
BOTH  
NONE  
To continue chilling without printing either, press the button  
to the left of where NONE is shown on the display.  
PRINTING  
To print a chill report for this probe, press the button to the right  
of where RECORD is shown on the display.  
PLEASE WAIT...  
To print a label for this probe, press the button to the right  
of where LABEL is shown on the display.  
To print a both chill report and label for this probe, press the  
button to the right of where BOTH is shown on the display.  
Multiple records and/or labels may be printed by pressing the  
appropriate button after previous printing is completed. When  
finished printing press NONE and the display will return to the  
MAIN MENU or PROBE MENU if there are still active probes.  
Repeat as necessary when each probe reaches completion.  
When all probes are DONE, return to the MAIN MENU.  
-12-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VII. OPERATING THE BLAST CHILL CONTROL - STARTING A CHILL CYCLE  
VII. b - STARTING A CHILL CYCLE - BY TIME:  
Use of the chilling mode BY TIME means that product will be constantly chilled  
until the set chill time, as determined by the operator, has elapsed, at which  
time the cycle is complete and operation reverts to normal refrigerated  
holding mode.  
MAIN MENU AIR 35°F  
BY TEMP  
BY TIME  
08:05:01  
BY PROD  
MORE  
Main Menu Display  
The main menu should be displayed on the control. To begin a chill cycle BY  
TIME follow the below instructions:  
MAIN MENU AIR 35°F  
STEP ONE:  
Press the button to the left of where BY TIME is shown on the  
display. The menu will then change to show TYPE : CHILL.  
BY TEMP  
BY TIME  
08:05:01  
BY PROD  
MORE  
STEP TWO: Select the TYPE by pressing the button to the left of where by  
TYPE is shown on the display. The display will toggle between  
CHILL (blast chill mode), SOFT (soft chill mode) and FREEZE  
(flash chill mode) each time you press this button.  
BY TIME  
TYPE: CHILL  
CYCLE TIME: 01:30↑  
MAIN  
START  
STEP THREE: Adjust the CYCLE TIME (not required) if you wish to deviate  
from the factory preset times (see chart below). This is done by  
pressing the buttons to the left and right of the UP and DOWN  
BY TIME  
TYPE: CHILL  
CYCLE TIME: 01:30↑  
MAIN START  
arrows.  
INITIAL TIME  
SETTING  
MODELS  
BY TEMP  
TIME RANGE  
NOTE: If desired you may insert the food  
probes into the food product as shown in  
section VI. a., however please be aware  
that these will only display the product  
temperatures and have no effect on the  
chilling process in this mode.  
All Models Blast Chill  
All Models Soft Chill  
All Models Freeze  
01:30  
00:01 To 09:00  
00:01 To 09:00  
00:01 To 09:00  
01:30  
01:30  
STEP FOUR: Close the door. You are now ready to begin chilling. If you are  
satisfied with the selections made in steps 1 thru 3, press the  
button to the right of where START is shown on the display. The  
chill time remaining will display in the lower left corner of the  
display: Hr: Min: Sec: (hours:minutes:seconds).  
BY TIME  
TYPE: CHILL  
CYCLE TIME: 01:30↑  
START  
MAIN  
NOTE: Prior to selecting START you can return to the MAIN MENU at any time  
by pushing the button to the left of where MAIN is shown on the display.  
BY TIME  
TYPE: CHILL  
CYCLE TIME: 01:30↑  
MAIN  
When a programmed batch has reached completion (i.e. the timer has counted  
down to 0:00:00) the alarm will activate, providing an audible notification  
(buzzer). This can be turned OFF by pressing the button to the right of where MUTE  
is shown on the display.  
START  
HOLDING  
1 41°F  
2 44°F  
1:16:01  
AIR: 14°F  
NOTE: After completion of a batch the unit will return to normal refrigerated  
holding temperatures (37°F). Product which was either BLAST or SOFT  
chilled may remain in the blast chiller. However, if a FREEZE CHILL cycle was  
completed product must be removed immediately upon batch completion.  
43°F 3  
MUTE  
HOLDING  
1 159°F  
2 154°FBY TIME  
1:30:00 STOP/RESET  
AIR 35°F  
OTHER BY TIME CONTROL FUNCTIONS  
156°F 3  
During a chill cycle BY TIME, the control has several preset functions that  
can be accessed by pressing the button to the left of where STOP/RESET is  
shown on the display.  
BY TIME  
ADD 30 MINUTES  
RESET TIMER  
ADD 30 MINUTES: adds 30 additional minutes to the timer.  
RESET TIMER: re-starts the timer at the original time setting.  
CONTINUE: resumes the cycle at the time remaining.  
STOP: control returns to the MAIN MENU.  
STOP  
CONTINUE  
-13-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VII. OPERATING THE BLAST CHILL CONTROL - STARTING A CHILL CYCLE  
VII. c - STARTING A CHILL CYCLE - BY PRODUCT:  
Use of the chilling mode BY PRODUCT allows the operator to select from a  
listing of chill parameters for various previously programmed products.  
These products will then be chilled either BY TEMPERATURE or BY TIME,  
depending upon their individual settings. When the chill cycle is completed  
operation reverts to normal refrigerated holding mode.  
MAIN MENU AIR 35°F  
BY TEMP  
BY TIME  
08:05:01  
BY PROD  
MORE  
Main Menu Display  
The main menu should be displayed on the control. To begin a chill cycle BY  
PRODUCT follow the below instructions:  
MAIN MENU AIR 35°F  
BY TEMP  
BY TIME  
08:05:01  
BY PROD  
STEP ONE:  
Insert the food probes into the food product as shown in  
section VI. a and close the door.  
MORE  
BY PRODUCT  
TYPE: CHILL  
TARGET TEMP: 37°F↑  
STEP TWO: Press the button to the right of where BY PRODUCT is shown  
on the display. The menu will then change to show TYPE:  
CHILL.  
MAIN  
START  
SELECT USER:  
TIM SMITH  
STEP THREE: Select the USER (if more than one user has been previously  
entered) by pressing the buttons to the left and right of the UP  
and DOWN arrows.  
BACK  
SELECT  
STEP FOUR: Select the PRODUCT to be chilled. The display will show the  
two most recently chilled products. You can scroll through the  
listing of products by pressing the buttons to the left of the UP  
and DOWN arrows. See page 16 for more information.  
SELECT PRODUCT:  
CHICKEN PARTS  
SOUP VEGETABLE  
MAIN MENU  
SELECT PRODUCT:  
CHICKEN PARTS  
SOUP VEGETABLE  
STEP FIVE:  
Once the product you wish to chill is shown on the display,  
press the button to the right of where this is shown to recall  
that products chill paramaters and begin chilling.  
MAIN MENU  
If the product selected is being chilled BY TEMPERATURE, the  
chill cycle time will be shown in the lower left corner of the  
display: Hr: Min: Sec: (hours:minutes:seconds).  
NOTE: If the product you wish to se-  
lect is on the Product List shown on  
page 20 but is not available from the  
SELECT PRODUCT menu of the con-  
trol display, it first needs to be enabled.  
The Supervisor should refer to Set-Up  
Products on page 23.  
If the product selected is being chilled BY TIME, the time  
remaining will be shown in the lower left corner of the display:  
Hr: Min: Sec: (hours:minutes:seconds).  
NOTE: You can return to the MAIN MENU at any time by pushing the button to  
the left of where MAIN is shown on the display.  
When a programmed batch has reached completion the alarm will activate,  
providing an audible notification (buzzer). This can be turned OFF by pressing  
the button to the right of where MUTE is shown on the display.  
(This step is repeated as each probe reaches the target temperatures; see page 14).  
NOTE: After completion of all batches the unit will return to normal refrigerated  
holding temperatures (37°F). Product which was either BLAST or SOFT  
chilled may remain in the blast chiller. However, if a FREEZE CHILL cycle was  
completed product must be removed immediately upon batch completion.  
Refer to page 14 or 19 for printing procedures and information.  
-14-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VII. OPERATING THE BLAST CHILL CONTROL - STARTING A CHILL CYCLE  
VII. d - THE CHILL BY PRODUCT FEATURE - PRODUCT LIST:  
Any product from the PRODUCT LIST can be chilled using the BY PROD mode, once it has been enabled in Setup  
Products (page 22). Only CHICKEN PARTS and SOUP VEGETABLE are initially enabled as preset at the factory.  
NOTE: All products are initially set in the BY TEMP - CHILL mode with a Target Temperature of 37°F and Holding  
Temperature of 37°F.  
ASPARAGUS  
BEANS  
LAMB  
SALAD POTATO  
SANDWICHES  
SAUCE  
LASAGNA  
BEANS BAKED  
BEEF  
LIVER  
MACARONI & CHEESE  
MACARONI & GROUND BEEF  
MEAT  
SAUCE CHEESE  
SAUCE MEAT  
SAUCE TOMATO  
SAUSAGE  
BEEF CREAMED  
BEEF ROAST  
BEEF TIPS  
MEAT GROUND  
MEAT LOAF  
BROCCOLI  
SOUP BEAN  
CABBAGE STUFFED  
CARROTS  
MEAT SLICED  
MEAT WITH SAUCE  
OATMEAL  
SOUP CREAM OF CELERY  
SOUP POTATO  
SOUP TOMATO  
SOUP VEGETABLE  
SPAGHETTI  
CASSEROLE  
CEREAL COOKED  
CHICKEN & DUMPLINGS  
CHICKEN PARTS  
CHICKEN POT PIE  
CHOWDER CORN  
COLE SLAW  
PASTA  
PEAS  
PEPPERS STUFFED  
PORK  
STARCH DISH  
STEAK  
PORK CHOPS  
POTATO MASHED  
POTATO SLICED  
POTATOES  
STEAK CHOPPED  
STEAK SALISBURY  
STEAK SWISS  
STEW  
COMBINATION DISHES  
CORN  
DRESSING CORNBREAD  
FISH BAKED  
FISH BREADED  
GRAVY  
POTATOES SCALLOPED  
POULTRY  
STEW BEEF  
TACO MEAT  
POULTRY SLICED  
POULTRY WITH SAUCE  
PRE PLATES  
RICE  
TUNA SALAD  
TURKEY BREAST  
TURKEY ROAST  
VEAL CHOPS  
VEGETABLES  
GRITS  
HAM  
JELLO  
ROAST WHOLE  
NOTE: A list of the products can be printed by holding the button by MAIN MENU then pressing  
BY PRODUCT.  
-15-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VII. OPERATING THE BLAST CHILL CONTROL - HOLD MODE & DEFROST  
VII. e - REFRIGERATED HOLD MODE:  
At the completion of a chill cycle, regardless of the mode used, the Traulsen  
blast chiller reverts to normal refrigerated holding mode of 37°F. Hold mode  
can also be manually selected at any time (i.e. interrupting the chill cycle) by  
using the HOLD MODE feature. When in the holding mode both the mainteance  
and blast chill compressors will operate during cooling portions of the cycle.  
MAIN MENU AIR 35°F  
BY TEMP  
BY TIME  
08:05:01  
BY PROD  
MORE  
Main Menu Display  
The main menu should be displayed on the control. To initiate a HOLD MODE  
follow the below instructions:  
MAIN MENU AIR 35°F  
STEP ONE:  
From the MAIN MENU, select MORE by pressing the button to  
the right of where this is shown on the display. The menu  
shown will then change to display additional menu options.  
BY TEMP  
BY TIME  
08:05:01  
BY PROD  
MORE  
STEP TWO: Press the button to the left of where HOLD PROD (hold product)  
is shown on the display.  
HOLDING  
1 37°F  
2 37°F  
0:00:04  
AIR: 34°F  
37°F 3  
HOLDING will show on the display. The timer will indicate run  
time in the lower left corner of the display: Hr: Min: Sec:  
(hours:minutes:seconds).  
NOTE: HOLD mode does not retain temperature vs. time data in memory; as  
a result printed reports are not available.  
EXIT  
VII. f - DEFROST:  
When not in a chill cycle, the Traulsen blast chiller will automatically start a  
defrost cycle every three hours while in refrigerated HOLD mode. However, a  
defrost can also be manually initiated by following the below procedure.  
STEP ONE:  
From the MAIN MENU, select MORE by pressing the button to  
the right of where this is shown on the display. The menu  
shown will then change to display additional menu options.  
MAIN MENU AIR 35°F  
BY TEMP  
BY TIME  
08:05:01  
BY PROD  
MORE  
STEP TWO: Press the button to the left of where DEFROST is shown on the  
display. The menu will then change slightly to show REMOVE  
FOOD, CANCEL and START.  
Main Menu Display  
MAIN MENU AIR 35°F  
BY TEMP  
BY TIME  
08:05:01  
BY PROD  
NOTE: Remove food from the blast chiller before proceeding.  
MORE  
STEP THREE: Press the button to the right of where START is shown on the  
display to initiate a manual defrost cycle. The defrost cycle will  
run for 40 minutes or until both the maintenance and blast chill  
coil temperatures reach 50°F. Once initiated, the defrost cycle  
will only terminate on time or temperature, and cannot be  
manually terminated.  
MAIN MENU 08:06:01  
HOLD PROD  
DEFROST  
BACK  
PRINT  
SETUP  
READY TO DEFROST  
REQUIRED IN XX MIN.  
REMOVE FOOD  
For model RBC100, a common evaporator coil is used for the  
both the blast chill and maintenance compressors.  
CANCEL  
START  
XX = Number of minutes until next scheduled defrost.  
DEFROSTING  
MAINT 50°F  
BLAST 49°F  
00:10:05  
-16-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VII. OPERATING THE BLAST CHILL CONTROL - PRINTING  
VII. g - PRINTING BATCH/CHILL CYCLE DATA:  
Once a chill cycle is complete, data can be printed.  
MAIN MENU AIR 35°F  
BY TEMP  
BY TIME  
08:05:01  
BY PROD  
MORE  
MAIN MENU 08:06:01  
HOLD PROD  
DEFROST  
BACK  
PRINT  
SETUP  
PRINT: CYCLE  
4/03 08:40  
PRB#1 RECORD  
MAIN MENU PRINT  
Press to select DATA.  
Press to change to a previous date.  
For multi-batching, press to select probe.  
Press to return to MAIN MENU.  
Press to change to a future date.  
Press to select LABEL or BOTH.  
Press to print selection.  
However, the following information can always be printed.  
PRINT: DATA  
Press to select LIST.  
Press to change to a previous date.  
4/03 08:00  
12 HOUR LOG  
MAIN MENU PRINT  
Press to change to a future date.  
Press to print selection.  
Press to return to MAIN MENU.  
Standard On-Board Printer Sample  
Optional Label Printer Sample  
CHILL CYCLE REPORT  
MODE: FREEZE  
CHILL CYCLE REPORT  
MODE: FREEZE  
FOOD PRODUCT:SOUP VEGETABLE  
FOOD PRODUCT:SOUP VEGETABLE  
USER: BOB SMITH  
USER: BOB SMITH  
PROBE #2  
PROBE #2  
STARTED: 04/11/03 13:08  
STARTED: 04/11/03 13:08  
REMOVED: 04/11/03 13:08  
CYCLE TIME: 358 MINUTES  
0
40  
70  
140  
13:09  
13:10  
13:11  
13:12  
13:13  
13:14  
13:15  
13:16  
13:17  
13:18  
13:19  
13:20  
13:21  
13:22  
13:23  
13:24  
13:25  
13:26  
13:27  
13:28  
13:29  
13:30  
112  
106  
96  
89  
84  
79  
75  
70  
66  
63  
60  
57  
54  
51  
49  
49  
47  
46  
44  
42  
40  
38  
HIGHEST: 140  
TIME TO 70  
TIME TO 40  
°
F
LOWEST -7  
F: 45 MINUTES  
F: 75 MINUTES  
°F  
°
°
NOTE:  
When printing at the end of a BY TEMP cycle, the controller will print  
an abbreviated Chill Cycle Report. Only the data from when the cycle  
started until the desired target temperature was reached will be  
printed. If for any reason after reaching the set temperature the  
temperature increased above 40F during the HOLD cycle, that  
information will be printed at the bottom of the Chill Cycle Report,  
REMOVED: 04/11/03 13:08  
CYCLE TIME: 358 MINUTES  
HIGHEST: 140  
TIME TO 70  
TIME TO 40  
°
F
LOWEST -7  
F: 45 MINUTES  
F: 75 MINUTES  
°F  
°
°
-17-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VII. OPERATING THE BLAST CHILL CONTROL - SET UP PRODUCTS  
VII. h- SET-UP PRODUCTS:  
MAIN MENU AIR 35°F  
Pages 15 and 16 describe the chill BY PRODUCT mode, where the operator can  
choose from a preprogrammed list of product chill parameters. As shipped  
from the factory, only two products on the list are enabled and ready from  
immediate use (chicken parts and vegetable soup). To enable any of the other  
food products which appear on the list please follow the below procedure.  
BY TEMP  
BY TIME  
08:05:01  
BY PROD  
MORE  
STEP ONE:  
From the MAIN MENU, select MORE by pressing the button to  
the right of where this is shown on the display. The menu  
shown will then change to display additional menu options.  
MAIN MENU AIR 35°F  
BY TEMP  
BY TIME  
08:05:01  
BY PROD  
MORE  
STEP TWO: Press the button to the right of where SETUP is shown on the  
display. NotewhenyoufirstenterSETUP, onlyPresetSupervisor  
is available. On the PASSWORD (PIN) line, use the UP or DOWN  
keys until 57 is displayed as the Preset Supervisors Personal  
Identification Number. Press ENTER. The menu shown will  
then change back to display the SETUP menu options.  
MAIN MENU 08:06:01  
HOLD PROD  
DEFROST  
BACK  
PRINT  
SETUP  
SELECT SUPERVISOR:  
PRESET SUPERVISOR↑  
PASSWORD (PIN): 00↑  
If users have already been setup, select the supervisors name  
using the UP or DOWN keys. On the next line, use the UP or  
DOWN keys to enter their Password (or Personal Identification  
Number). Press ENTER. The menu shown will then change  
back to display the SETUP menu options.  
CANCEL  
ENTER  
SELECT SUPERVISOR:  
TIM SMITH  
PASSWORD (PIN): 57↑  
STEP THREE: Press the button to the left of where PRODUCTS is shown on  
the display.  
CANCEL  
SETUP  
ENTER  
STEP FOUR: Press the button to the left of where ENABLE / DISABLE is  
shown on the display to choose what products are enabled on  
the product list (only an enabled product is available to chill BY  
PRODUCT).  
09:04:11  
PRODUCTS SYS PAR  
USERS  
MAIN MENU  
STEP FIVE:  
Press the button to the right of where BACK is shown on the  
display in order to save the revised BY PRODUCT listing.  
SETUP PRODUCTS:  
ENABLE/DISABLE  
EDIT SETTINGS  
BACK  
NOTE: If it is necessary to edit the settings (BY TEMPERATURE or BY TIME  
and their associated endpoints) please proceed by using the below procedure.  
STEP ONE:  
Select ENABLE / DISABLE to choose what products are enabled  
from the Product List. Only an enabled product is available to  
chill BY PRODUCT.  
PRODUCT SELECTION:  
ASPARAGUS  
ENABLED: NO  
EDIT  
BACK  
STEP TWO: Select EDIT SETTINGS to adjust chill parameters for any product  
that has already been enabled (BACK returns to SETUP).  
SETUP PRODUCTS:  
ENABLE/DISABLE  
EDIT SETTINGS  
STEP THREE: After selecting ENABLE / DISABLE, use the UP or DOWN keys  
to select a product from the list. Press to change ENABLED:  
NO to YES to enable the product or to change YES to NO to  
disable it. The two most recently chilled products cannot be  
disabled. BACK saves the enabledand returns to SETUP  
PRODUCTS.  
BACK  
ASPARAGUS  
TYPE: CHILL  
TARGET TEMP: 37°F↑  
BY TEMP  
MORE  
STEP FOUR: After selecting EDIT SETTINGS, use the UP or DOWN keys to  
select a product. Finish all the below steps to change any  
setting(s).  
ASPARAGUS  
HOLD TEMP:  
37°F↑  
CANCEL  
SAVE  
Select the Type: CHILL, SOFT CHILL or FREEZE.  
Select BY TEMP or BY TIME. Use the or keys to adjust the TARGET  
TEMP if BY TEMP is displayed, or to adjust the CYCLE TIME if BY TIME is  
displayed.  
BACK  
ASPARAGUS  
HOLD TEMP:  
37°F↑  
CANCEL  
Select MORE and use the or keys to adjust the HOLD TEMP.  
Press SAVE to keep the changes and return to SETUP PRODUCTS.  
(CANCEL returns to SETUP PRODUCTS without saving the changes.  
BACK  
SAVE  
BACK returns to the previous screen).  
-18-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VII. OPERATING THE BLAST CHILL CONTROL - SET UP USERS  
VII. h - SET-UP USERS:  
MAIN MENU AIR 35°F  
The SmartChill® control offers the convenience of having individual operators  
have their own unique BY PRODUCT and SYSPAR settings already  
programmed, facilitating the changing chilling needs of different production  
shifts. To add new user settings please follow the below procedure.  
BY TEMP  
BY TIME  
08:05:01  
BY PROD  
MORE  
MAIN MENU AIR 35°F  
STEP ONE:  
From the MAIN MENU, select MORE by pressing the button to  
the right of where this is shown on the display. The menu  
shown will then change to display additional menu options.  
BY TEMP  
BY TIME  
08:05:01  
BY PROD  
MORE  
STEP TWO: Press the button to the right of where SETUP is shown on the  
display. NotewhenyoufirstenterSETUP, onlyPresetSupervisor  
is available. On the PASSWORD (PIN) line, use the UP or DOWN  
keys until 57 is displayed as the Preset Supervisors Personal  
Identification Number. Press ENTER. The menu shown will  
then change back to display the SETUP menu options.  
MAIN MENU 08:06:01  
HOLD PROD  
DEFROST  
BACK  
PRINT  
SETUP  
If users have already been setup, select the supervisors name  
using the UP or DOWN keys. On the next line, use the UP or  
DOWN keys to enter their Password (or Personal Identification  
Number). Press ENTER. The menu shown will then change  
back to display the SETUP menu options.  
SETUP  
09:04:11  
PRODUCTS SYS PAR  
USERS  
MAIN MENU  
STEP THREE: Press the button to the left of where USERS is shown on the  
display.  
SETUP USERS:  
ADD DELETE ALL  
EDIT/DELETE  
STEP FOUR: Press the button to the left of where ADD is shown on the  
display to add new users to the roster.  
NOTE: The first user entered is automatically given Supervisor  
access. This can be changed by using the EDIT/DELETE  
selection to change a given users security level or PIN number,  
or delete an entire user from the roster. DELETE ALL removes  
all users from the roster.  
BACK  
SELECT SUPERVISOR:  
TIM SMITH  
PASSWORD (PIN): 07↑  
CANCEL  
ENTER  
STEP FIVE:  
To enter the name of a new user, press the buttons to the left  
and right of the UP and DOWN arrows to scroll through the  
alphabet, one character at a time. Press the button to the right  
of where NEXT is shown on the display to set this character and  
move on to the next letter, repeating this until the new users  
name is complete.  
ENTER NAME:  
_  
BACK  
NEXT  
ENTER  
CANCEL  
ENTER NAME:  
TIM SMITH  
BACK  
NOTE: BACK moves the cursor one space to the left to allow for  
editing. Press the button to the right of where ENTER is shown  
on the display to save the new users name (CANCEL aborts this  
process).  
NEXT  
ENTER  
CANCEL  
STEP SIX:  
Select the new users security level by pressing the button to  
the right of where SECURITY LEVEL is shown on the display  
(pressing this button toggles between OPER (operator level)  
and SUPV (supervisor). Please note that at least one user must  
already be set-up as a supervisor before an operator access  
level can be selected.  
SETUP USER:  
SECURITY LEVEL:0PER  
PASSWORD (PIN): 00↑  
ENTER  
SETUP USER:  
SECURITY LEVEL:0PER  
PASSWORD (PIN): 23↑  
ENTER  
STEP SEVEN: To enter the new use’s two-digit PASSWORD, press the buttons  
to the left and right of the UP and DOWN arrows to scroll  
through the numbers 00-99. Press the button to the right of  
where ENTER is shown on the display to set this users  
access level and pin number. The display will return to the SET-  
UP USERS menu. Press the button to the right of where BACK  
is shown on the display to return to the SETUP menu. Press the  
button to the left of where MAIN is shown on the display to  
return to the main menu.  
SETUP USER:  
SECURITY LEVEL:0PER  
PASSWORD (PIN): 23↑  
ENTER  
-19-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VII. OPERATING THE BLAST CHILL CONTROL - SYSPAR  
VII. i - ACCESSING SYS PAR SETTING LEVEL:  
MAIN MENU AIR 35°F  
SYS PAR represents the supervisor level of access to the SmartChill® controller,  
allowing on-site adjustment to the factory preset operating parameters.  
BY TEMP  
BY TIME  
08:05:01  
BY PROD  
MORE  
To enter the SYSPAR access level please follow the below procedure.  
MAIN MENU 08:06:01  
STEP ONE:  
From the MAIN MENU, select MORE by pressing the button to  
the right of where this is shown on the display. The menu  
shown will then change to display additional menu options.  
HOLD PROD  
DEFROST  
BACK  
PRINT  
SETUP  
STEP TWO: Press the button to the right of where SETUP is shown on the  
display. NotewhenyoufirstenterSETUP, onlyPresetSupervisor  
is available (as delivered, only the factory preset supervisor’s  
PIN access or ID is set-up).  
SELECT SUPERVISOR:  
PRESET SUPERVISOR↑  
PASSWORD (PIN): 00↑  
CANCEL  
ENTER  
Press the buttons to the left and right of where PASSWORD is  
shown on the display to scroll to the factory preset PIN of  
57.Press the button to the right of where ENTER appears on  
the control to enter this PIN number. The SETUP display menu  
is displayed.  
SELECT SUPERVISOR:  
PRESET SUPERVISOR↑  
PASSWORD (PIN): 57↑  
CANCEL  
ENTER  
MAIN MENU 08:06:01  
NOTE:  
If users have already been setup, select the supervisors name  
using the UP or DOWN keys. On the next line, use the UP or  
DOWN keys to enter their Password (or Personal Identification  
Number). Press the button to the right of where ENTER appears  
on the control to enter this selection. The SETUP display menu  
is displayed.  
HOLD PROD  
DEFROST  
BACK  
PRINT  
SETUP  
SETUP  
09:04:11  
PRODUCTS SYS PAR  
USERS  
MAIN MENU  
STEP THREE: From the SETUP display menu , select the button to the right of  
where SYS PAR is shown on the display. Refer to the diagram  
on page 21 in order to access the various Sys Par settings  
SYS PAR: SET CLOCK  
ITEM:  
MONTH  
VALUE:APRIL  
CANCEL  
ENTER  
SYS PAR Menu Display  
-20-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VII. OPERATING THE BLAST CHILL CONTROL - SYSPAR  
VII. j - SYSPAR - SETTING THE VARIOUS CONTROL FEATURES:  
By accessing SYSPAR (system parameters), the operator can adjust many  
control features to better suit their operational needs, such as: Clock Settings,  
Probes, Temperature Scale (F or C), Alarm Settings and Chill Parameters. It  
also provides for an easy return to the original factory default settings with a  
RESET feature.  
From the SETUP screen, select SYS PAR to get:  
Press to select SYS PAR.  
Press to decrease ITEM.  
Press to decrease VALUE.  
Press to return to MAIN MENU*  
*without saving.  
Press to select SYS PAR.  
SYS PAR: SET CLOCK  
ITEM:MONTH  
VALUE:APRIL  
Press to increase ITEM.  
Press to increase VALUE.  
Press to return to SETUP with saving.  
CANCEL  
ENTER  
SYS PAR Menu Display  
1) SET CLOCK  
SYS PAR: SET CLOCK  
ITEM:MONTH  
VALUE:APRIL  
a)  
b)  
c)  
d)  
e)  
f)  
MONTH (JANUARY – DECEMBER)  
DATE (1 – 311 )  
YEAR (2003 – 2079)  
DAY OF WEEK (SUNDAY – SATURDAY)  
HOUR (0 – 23)  
MINUTE (0 – 59)  
CANCEL  
ENTER  
SYS PAR: SET CLOCK  
ITEM:DATE  
VALUE:04/XX/00  
g)  
DLS TIME (ENABLED – DISABLED)  
2) PROBES  
CANCEL  
ENTER  
a)  
c)  
1 (ON – OFF) b)  
3 (ON – OFF)  
2 (ON – OFF)  
SYS PAR: SET CLOCK  
ITEM:YEAR  
VALUE:04/14/XX  
3) DISPLAY  
4) LOGGING  
5) ALARM  
a)  
a)  
TEMPERATURES (IN DEG C – IN DEG F)  
TIME (5-MINUTES – 30-MINUTES)  
CANCEL  
ENTER  
SYS PAR: SET CLOCK  
ITEM:HOUR  
VALUE:XX:00  
a)  
b)  
c)  
d)  
e)  
CYCLE RUNNING (NO – yes)  
CYCLE ENDS (NO – yes)  
PRINTER ERROR (NO – yes)  
HIGH/LOW TEMP (no – YES)  
POWER FAILURE (no – YES)  
CANCEL  
ENTER  
SYS PAR: SET CLOCK  
ITEM:MINUTE  
VALUE:10:XX  
6) REMINDERS  
a)  
7) BLAST  
DOOR OPEN (0 – 2 MINUTES)  
CANCEL  
ENTER  
a)  
c)  
e)  
TARGET (33 – 40)  
HOLD (10 – 40)  
b)  
d)  
AIR (10 – 40)  
HIGH ALARM (35 – 60)  
LOW ALARM (-30 – 34)  
8) SOFT CHILL  
a)  
BY TEMP (5 – 20)  
b)  
BY TIME (10 – 90)  
c)  
2ND TEMP (10 – 40)  
9) FREEZE CHILL  
a)  
c)  
TARGET (-22 – 28)  
HOLD (10 – 40)  
b)  
d)  
AIR (-32 – 20)  
HIGH ALARM (20 – 45)  
e)  
10) RESET  
a)  
LOW ALARM (-30 – 0)  
PARAMETERS (YES – NO)  
1
Last day is corrected for month and leap year.  
-21-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VIII. SMARTCHILLTM COMMUNICATIONS  
VIII. a - INTRODUCTION:  
All Traulsen SmartChill® equipped blast chiller models are supplied from the factory capable of on-line communi-  
cations. However, an optional software/hardware kit is required to make this compatible with your PC. Use of  
this provides many user advantages, such as:  
Retrieving Batch/Chill Cycle Data  
Viewing Users and Their Status  
Exporting Data To A Spreadsheet  
Adding Additional Products To The BY PRODUCT Mode  
VIII. b - SYSTEM REQUIREMENTS:  
IBM PC, Pentium II 300mhz or greater, Windows 95, 98, 2000, ME or NT operating system, 10 x CD ROM Drive, 64  
MB RAM, 800 x 600 display, 24 bit color support.  
VIII. c - OPERATION:  
For more information and operation detail, please refer to the SmartChill® Communications Users Guide, form  
number TR35853.  
VIII. d - COMMUNICATION WITH SMARTCHILL®:  
During communication with the SmartChill® program on a PC, the screen below displays.  
COMMUNICATING WITH  
COMPUTER  
PLEASE WAIT...  
VIII. e - HARDWARE CONNECTION:  
To utilize the communication features of the SmartChill® control, it is necessary to connect this to a PC  
using its RS232 data port. See form number TR35853 for more information.  
-22-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IX. GLOSSARY  
Alarms: Sets buzzer intervals after Door is Open or when to be notified that the Compressor needs to be Cleaned.  
By Temp: Chill cycle that terminates when the probes reach the Target Temperature.  
By Time: Chill cycle that terminates after a set amount of time has lapsed.  
By Prod: Chill cycle that terminates after a particular product’s specified chill parameters are met (the parameters  
can be set either By Temp or By Time with specific cut-offs for a particular product.  
Chill: Chilling Cycle that may end with either Time or Temperature controlled events. (Also see Soft Chill or  
Freeze).  
Clock: Allows the Date and Time to be entered so the system’s clock correctly records chilling events.  
Cycle #: The system assigns a consecutive number to each Chill Cycle.  
Defrost: System Controlled Defrost occurs after three hours of chilling (this can also be set to occur at between  
2 - 6 hours). The defrost will not begin during a chill cycle. The system waits until it is in Holding mode before starting  
the defrost cycle. The Defrost from the Main Menu is a manual defrost that will not run if selected and unneeded.  
The Defrost cycle requires about 30 minutes (this can also be set from 20 - 60 minutes in duration as needed).  
Fac Presets: Factory Presets are system parameters that are set at the factory but can be changed by the  
supervisor.  
Freeze: This mode allows the product to be frozen down to a target temperature. The target temperature range  
available for freeze mode varies from -22°F to 28°F.  
Hold Prod: After completed chill cycle or when selected from the Main Menu, the chiller will act like a regular  
refrigerator.  
Label: A condensed Chill Cycle Report that can be printed on adhesive-backed label stock by the label printer.  
Logging: The time interval at which Chill Cycle data (temperature vs. time) is logged into memory for record  
purposes. The factory setting is 5 minutes.  
Main Menu: The two initial menus available from the controller after the chiller is turned on.  
Mode: Basic chiller operating parameters are available from Sys Par in Setup mode.  
Chill mode parameters allow adjustment of the target temperature, the air temperature during chill mode, the hold  
mode temperature, the high alarm temperature, the low alarm temperature and the maximum chill mode target  
temperature. Soft Chill mode parameters apply a modification of some of the Chill settings during the final portion  
of the chill cycle if Soft Chill is selected. Soft Chill provides additional protection against freezing of surfaces.  
Oper: An Operator is a user who is allowed to operate the chiller and make reports of chill cycles performed.  
Print: Allows a report of any Chill Cycle and probe to be printed. Chillers equipped with the optional second printer  
can print the condensed ‘Label’ type of report. All Chillers can print the ‘Record’ type of report.  
Probe #: Each probe is numbered and its temperature vs. time is recorded for each probe # during every BY TEMP  
chill cycle and the record can be printed, either at the end of the chill cycle or subsequently.  
Product List: A list of products in system memory which can have individual chill parameters specifically set for  
each product (assuming that the product is already enabled). Refer to Setup Products.  
Record: Type of report that can be printed by all chillers. This report provides a record of time vs. temperature  
for a specific Probe and Chill Cycle.  
Remote Alarm: The chiller can be wired to a remote alarm which will close the remote alarm circuit in the event  
of one or more of the following situations: Printer Error, Cycle End, Door Open, High or Low Temperatures or Power  
Failure. If Cycle Running is chosen, the remote alarm circuit will close when a chill cycle is running and all other  
remote alarm settings are overridden (reset to NO). The supervisor can determine which events the remote alarm  
will signal by adjusting the settings in the Sys Par (System Parameters) section.  
Setup: Specific control settings that can be set by the supervisor which determine how the chiller will operate.  
Soft Chill: Type of chill process that moderates the temperatures and fan speed near the end of the chill cycle to  
provide less risk of freezing at the product’s surface.  
Supv: A Supervisor is a user who is allowed to identify the users and limit their access to system parameters, enable  
products to be selected, set specific product chill parameters and change system parameters.  
Sys Par: System Parameters are control settings that determine how the chiller will operate. These settings can  
be adjusted by the supervisor in Setup mode.  
Temps in  
Temps in  
°C: If so displayed on the Sys Par 1 screen, all temperatures will be recorded in °C (Celsius).  
°F: If so displayed on the Sys Par 1 screen, all temperatures will be recorded in °F (Fahrenheit).  
-23-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X. REPLACEMENT PARTS LIST  
MODEL NUMBER  
RBC50  
PART/DESCRIPTION  
CORDSET - 115V  
PART #  
333-13013-01  
900-60233-00  
344-13168-01  
401-60027-01  
701-60115-00  
500-60154-00  
701-60105-00  
344-60081-00  
344-28482-00  
344-28486-00  
344-28488-00  
344-28487-00  
345-60011-04  
345-60011-05  
346-60018-00  
346-60019-00  
SER-60461-00  
200-60059-00  
342-60014-00  
701-60741-00  
400-60003-00  
400-60004-00  
333-60331-00  
500-60138-00  
501-60409-00  
950-60355-00  
701-60724-01  
200-36064-00  
500-60138-00  
501-60409-00  
950-60355-00  
701-60724-01  
200-36064-00  
RBC50  
RBC50/RBC100  
RBC50  
RBC50  
RBC100  
POWER PACK ASSEMBLY  
6” HIGH STAINLESS STEEL LEGS  
STAINLESS STEEL SIDE PANEL  
UNIVERSAL TRAY SLIDE  
LOUVER ASSEMBLY  
DRAINPAN  
PROBE CABLE HOOK  
HINGE BODY  
HINGE COVER  
RBC100  
RBC100  
ALL MODELS  
ALL MODELS  
ALL MODELS  
ALL MODELS  
RBC100  
HINGE CAM  
HINGE BRACKET  
HORIZONTAL BREAKER CAP  
VERTICAL BREAKER CAP  
LOCK KEEPER  
LOCK KEEPER BRACKET  
SMARTCHILL® CONTROL KIT  
DOOR - HINGED RIGHT  
TRAY SLIDE  
PRINTER COVER  
STANDARD PRINTER PAPER  
LABEL PAPER  
SMART PROBE  
LOUVER ASSEMBLY  
ROLL-IN RAMP  
RECORD/LABEL PRINTER  
PRINTER COVER  
DOOR - HINGED LEFT  
LOUVER ASSEMBLY  
ROLL-IN RAMP  
RBC100  
RBC100/200/400  
RBC100/200/400  
RBC100/200/400  
RBC100  
RBC100  
RBC100  
ALL MODELS  
ALL MODELS  
ALL MODELS  
RBC200/200RT  
RBC200/200RT  
RBC200/200RT  
RBC200/200RT  
RBC200/200RT  
RBC400/400RT  
RBC400/400RT  
RBC400/400RT  
RBC400/400RT  
RBC400/400RT  
RECORD/LABEL PRINTER  
PRINTER COVER  
DOOR - HINGED LEFT  
-24-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XI. SUMMARY OF ERROR MESSAGES  
XI. a - FOOD PROBE ERROR DURING CHILL CYCLE BY TEMP:  
SYSTEM/CONTROL ERROR  
CURRENT PROBE IS BAD  
CHECK FOOD PROBES  
In the event of a food probe error during a BY TEMP chill cycle, the control  
automatically switches to a BY TIME chill cycle. The timer will begin to  
countdown from 90 minutes, at which time the chill cycle will be complete.  
PLUGGED IN  
EXIT  
XI. b - FOOD PROBE ERROR DURING CHILL CYCLE BY TIME:  
In the event of a food probe error during a BY TIME chill cycle, or during a  
refrigerated holding cycle, the control will no longer display a temperature  
for that probe.  
CHILLING AIR:  
10  
°F 3  
°F  
41  
2 37  
°F  
STOP/RESET  
FAILED PROBE (#1)  
XI. c - CHILL TIME EXCEEDED:  
In the event a chill cycle does not complete within six hours, the control  
automatically switches operation to a refrigerated holding cycle. This cycle  
will continue until the operate selects EXIT and returns to the main menu  
to choose another cycle option.  
SYSTEM/CONTROL ERROR  
CHILL TIME EXCEEDED  
CONTACT SERVICE!  
EXIT  
XI. d - DEFROST FAILURE:  
SYSTEM/CONTROL ERROR  
DEFROST FAILURE  
CONTACT SERVICE!  
EXIT  
Occurs when either a coil probe temperature falls below 25°F after a de-  
frost cycle, or in the event of a probe short circuit. Unit automatically  
switches to IDLE mode.  
XI. e - NO PRODUCT PROBES:  
SYSTEM/CONTROL ERROR  
NO PRODUCT PROBES  
CHECK FOOD PROBES  
Occurs when either a BY TEMP or BY PRODUCT chill cycle has been at-  
tempted, but no food probes are connected. Unit automatically switches  
to IDLE mode.  
USE BY TIME  
EXIT  
XI. f - OVER TEMPERATURE:  
SYSTEM/CONTROL ERROR  
OVER TEMPERATURE  
CONTACT SERVICE!  
Occurs when cabinet air temperature rises above 160°F. Unit automati-  
cally turns off all compressors, fans and defrost heaters. NOTE: To reset  
control after an OVER TEMPERATURE alarm it is necessary to either turn  
OFF or unplug the unit.  
TURN OFF/UNPLUG UNIT  
XI. g - PRODUCT DETECTED W/O CYCLE STARTED:  
Occurs when cabinet air temperature rises above 40F for ten minutes (with  
product in the unit but no chill cycle started). Unit automatically switches  
to a refrigerated holding cycle.  
PRODUCT DETECTED!  
STARTING HOLD MODE  
CHECK FOOD PROBES  
EXIT  
XI. h - CABINET AIR TEMPERATURE SENSOR:  
Occurs when the cabinet air sensor has shorted or is open. Unit automati-  
cally turns off compressors, fans and defrost heaters.  
AIR TEMP SENSOR  
NOT READING  
CONTACT SERVICE  
TURN OFF/UNPLUG UNIT  
NOTE: To reset the control after an air temperature sensor failure, it is  
necessary to turn off or unplug the unit and replace the faulty air tempera-  
ture sensor.  
-25-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XII. WARRANTY INFORMATION  
STANDARD DOMESTIC WARRANTY  
TRAULSEN warrants new equipment to the original purchaser, when installed within the United  
States against defective material and workmanship for one (1) year from the date of original  
installation. Under this warranty, TRAULSEN will repair or replace, at its option, including service  
and labor, all parts found to be defective and subject to this warranty. The compressor part (self-  
contained only) is warranted for an additional four (4) years. During this period TRAULSEN will  
supply replacement compressor(s) if deemed defective, however, all installation, recharging and  
repair costs will remain the responsibility of the owner.  
This warranty does not apply to damage resulting from fire, water, burglary, accident, abuse,  
misuse, transit, acts of God, terrorism, attempted repairs, improper installation by unauthorized  
persons, and will not apply to food loss.  
The remote compressor used on models RBC200 and RBC200RT, when purchased from Traulsen,  
is warranted for a period of five (5) years from the date of original installation. During this period  
TRAULSEN will supply replacement compressor if deemed defective, however, after the first year,  
all installation, recharging and repair costs will remain the responsibility of the owner.  
THERE ARE NO ORAL, STATUTORY OR IMPLIED WARRANTIES APPLICABLE TO TRAULSEN,  
INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS  
FOR ANY PARTICULAR PURPOSE WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE  
HEREOF. TRAULSEN SHALL HAVE NO OBLIGATION OR LIABILITY FOR CONSEQUENTIAL OR  
SPECIAL DAMAGES, GROWING OUT OF OR WITH RESPECT TO THE EQUIPMENT OR ITS SALE,  
OPERATION OR USE, AND TRAULSEN NEITHER ASSUMES NOR AUTHORIZES ANYONE ELSE TO  
ASSUME FOR IT ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THE EQUIPMENT OR ITS  
SALE, OPERATION OR USE OTHER THAN AS STATED HEREIN.  
INTERNATIONAL COMMERCIAL WARRANTY  
(for Canadian warranties see domestic US warranty)  
TRAULSEN warrants to the original purchaser the Refrigeration Equipment manufactured and sold by it  
to be free from defects in material and workmanship under normal use and service for a period of one (1)  
year from date of shipment. Under this warranty, TRAULSEN will reimburse the purchaser for the  
replacement of any part of said equipment (excluding dryers & refrigerant gas) which then proves to be  
defective. This warranty does not apply to damage resulting from fire, water, burglary, accident,  
abuse, misuse, transit, acts of God, terrorism, attempted repairs, improper installation by  
unauthorized persons, and will not apply to food loss.  
TRAULSENS standard warranty does not apply to Export Sales. Rather, for a period of one (1) year  
from date of original installation not to exceed Fifteen (15) months from date of shipment from factory,  
TRAULSEN:  
will replace, F.O.B. factory, any defective parts normally subject to warranty.  
will not cover the cost of packing, freight or labor such costs being the sole responsibility of the  
dealer.  
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EITHER EXPRESSED OR IMPLIED AND  
CONSTITUTES TRAULSEN’S FULL OBLIGATION AND LIABILITY. WARRANTIES NOT AVAILABLE  
ON REMOTE MODELS.  
-26-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XIII. MECHANICAL TROUBLE SHOOTING GUIDE  
1. Condensing unit fails to start when programming a  
new batch.  
a. Check power supply to condensing unit.  
b. Batch was not programmed properly. Select chill method, press START, and if  
required select probes.  
c. System problem. Call for service.  
2. Batch requires too much time to chill product down to  
40° F. Chill Cycle Batch Over 6-Hours will ALARM  
and a printout will note the chill cycle has exceeded  
maximum safe time.  
a. Is the door closed properly? If not, close door completely.  
b. Too much product loaded. Adjust the load to not exceed capacity of the unit.  
c. Product depth in pan exceeds 2. Reduce pan load per guidelines on page 7.  
d. Has pan been covered with a lid, plastic wrap or foil, and is this not in direct contact  
with the product? Cover product correctly as per guidelines on page 7.  
e. Perhaps the product loaded is of a high density. Allow additional chilling time.  
f. Dirty condenser coil. Clean condenser as per instructions on page 6.  
g. Evaporator coil iced. Allow to defrost (press DEFROST to initiate a manual defrost).  
3. Food Probe Failure - ALARM will occur during a  
chill cycle batch with printout noting the Food Probe  
Failure Warning.  
a. Food Probe Failure - printer will notify the operator that it is converting to chilling BY  
TIME.  
b. When starting a BY TEMP cycle, if food probe is not available, there is an open circuit.  
Check the probe plug connection.  
c. Food probe was placed in excessively hot product. Product temperatures exceeding  
210° F can result in the probe reporting false temperatures. Cool food probe and test  
again.  
d. Food probe fails and will then operate correctly at a later time. Program a BY  
TEMP batch using the suspect probe. Wiggle the food probe wire. If a second Food  
Probe Failure occurs the food probe is defective. Replace with new food probe.  
g. Damaged or defective food probe. Replace with new food probe.  
4. Refrigeration Failure - ALARM with a printout  
noting the warning will occur when the interior  
temperature exceeds 100° F for more than 20-minutes.  
Blast Chill refrigeration system will shut down as a  
safety default. The compressors and blower fans are  
shut off and the control key pad is locked out.  
Refrigeration Failure CORRECTION - Remove power from the unit. Unplug and then  
replug the unit or reset the circuit breaker (OFF and back ON). The Blast Chiller will reset  
and turn ON. Power Loss Failure will printout when reset.  
a. Batch programming was incomplete or incorrect and chill cycle did not start. Try  
programming batch again.  
b. Too much product loaded. Adjust the load to not exceed capacity of the unit.  
c. Dirty condenser coil. Clean condenser as per instructions on page 6.  
d. Refrigeration system failure, unit will not cool after having been reset. Call service for  
repair.  
5. Power Loss Notification - Printout notes the time  
power was lost and the time in which it was restored.  
a. Power was lost to the Blast Chill unit. If product was inside the unit see the printout  
to determine if product temperature was compromised. The printout will show the  
temperature before and after the interruption.  
6. Cannot program a new batch.  
7. Printer not printing.  
a. Unit may be in a defrost cycle. Batch programming cannot be done while in a  
defrost cycle.  
b. If during a BY TEMP chill cycle, a new batch can be added by using the ADD/REMOVE  
option.  
a. Printer is out of paper. Replace printer paper roll as per instructions on page 6.  
b. Printer paper may be installed incorrectly. Verify that the thermal sensitive side  
of the paper is on the top and feed door closed, see instructions on page 6 or label in  
the printer cavity.  
c. Paper does not feed or jams behind the paper feed slot in the cover. Remove paper  
and reinstall as per instructions on page 6 or label in the printer cavity.  
8. No display on control.  
a. Check power supply and circuit breaker.  
b. Confirm unit is correctly plugged into a working power outlet.  
c. System problem. Call for service.  
9. Condensation on exterior surface.  
Condensation on the exterior surface of the unit is perfectly normal during periods of high  
humidity, otherwise refer below for other possible causes.  
a. Check door alignment and gasket for proper seal.  
b. On Roll-In/Roll-Thru models, check bottom door sweep for proper adjustment.  
c. Electric door heater malfunction. Call for service.  
Traulsen  
4401 Blue Mound Road Fort Worth, TX 76106  
Phone: (800) 825-8220 Fax-Svce: (817) 740-6757  
HOURS OF OPERATION:  
Monday thru Friday 7:30 am - 4:30 pm CST  
Quality Refrigeration  
© 2006 Traulsen - All Rights Reserved  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Tascam MP3 Player UH 7000 User Manual
Top Innovations Carpet Cleaner MC1227 User Manual
TRENDnet Network Router TEW 430APB User Manual
Trilogy Touch Technology Cell Phone 500 19 54 User Manual
Tripp Lite Fan 3U User Manual
Uniden Telephone DECT2015+1 User Manual
USRobotics Printer R24061600 User Manual
Vizio Computer Accessories CPU 56 User Manual
VocoPro CD Player CDG 1020PRO User Manual
Weber Gas Grill 3500 LX User Manual