Traulsen & Co., Inc.
Quality Refrigeration
OWNER’S MANUAL
Instructions for the installation
and maintenance of most Traulsen models as well as
instructions to operate the following special models:
Pizza Proofer Model
RPP232L-FHS
This Traulsen unit is built to our highest quality standards. We build our refrigerators, freezers and heated
cabinets this way as a matter of pride. This philosophy has made Traulsen the leader in commercial refrig-
eration since 1938. We thank you for your choice and confidence in Traulsen equipment and we know you
will receive many years of utility from this equipment.
All Traulsen units are placed on a permanent record file with the service department. In the event of any
future questions you may have, please refer to the model and serial number found on the name tag affixed
to the unit. Should you need service, however, call us on our toll free number, 800-825-8220 between 7:30
am and 4:30 pm CST, Monday thru Friday. It is our pleasure to help and assist you in every possible way.
INSTALLER
COMPLETE THE FOLLOWING INFORMATION PRIOR TO UNIT INSTALLATION
INITIAL START DATE:
MODEL TYPE:
SERIAL NO.
COMPANY/INDIVIDUAL NAME:
INSTALLER:
FORM NUMBER TR35848 REV. 8/03
P/N 375-60212-00
Download from Www.Somanuals.com. All Manuals Search And Download.
II. RECEIPT INSPECTION
III. INSTALLATION (continued)
All Traulsen products are factory tested for perfor-
mance and are free from defects when shipped. The
utmost care has been taken in crating this product to
protect against damage in transit. All interior fittings
have been carefully secured and the legs or casters
are boxed and strapped inside to prevent damage.
Door keys will be attached to the handle with a nylon
strip. The handle is protected by an easily removable
nylon netting.
III. c - ROLL-IN MODEL INSTALLATION:
Roll-In cabinets set on the floor require the floor area
to be flat and level. In addition, after the cabinet is set
in place, sealant should be used around the perimeter
of the base to comply with National Sanitation Foun-
dation requirements (see figure 1). After sealing the
unit, the enclosed ramp should then be installed.
SEALING BASE OF ROLL-IN MODELS
You should carefully inspect your Traulsen unit for
damage during delivery. If damage is detected, you
should save all the crating materials and make note
on the carrier’s Bill Of Lading describing this. Afreight
claim should be filed immediately. If damage is sub-
sequently noted during or immediately after installa-
tion, contact the respective carrier and file a freight
claim. Under no condition may a damaged unit be re-
turned to Traulsen & Co. without first obtaining writ-
ten permission (return authorization).
A
SEALANT MUST BE USED
AROUND THE PERIMETER OF THE
BASE OF CABINET AS SHOWN TO
FULLYCOMPLYWITH SANITARY RE-
QUIREMENTS.
A RECOMMENDED SEALANT IS
DOW CORNING SILASTIC RTV #732
III. INSTALLATION
Fig. 1
III. a - LOCATION:
Select a proper location for your Traulsen unit, away
from extreme heat or cold. Allow enough clearance
between the unit and the side wall in order to make
use of the door stay open feature at 120° (self-closing
feature operates up to 90°). The door(s) must be able
to open a minimum of 90° in order to make use of the
maximum clear door width available.
A stainless steel threshold ramp(s) is included to fa-
cilitate rolling in racks. It is shipped wrapped in brown
paper and secured to the rack guides inside the cabi-
net. To secure it in place, remove the two thumb
screws in the breaker strip near the bottom door open-
ing. Next, loosen the thumb screws located along the
floor at the threshold. Place the ramp(s) on top of the
loosened thumb screws and secure tabs on each end
to breaker strips with thumb screws previously re-
moved. After installing the ramp(s), it too should be
sealed to the floor.
III. b - PACKAGING:
All Traulsen units are shipped from the factory bolted
to a sturdy wooden pallet and packaged in a durable
cardboard container. The carton is attached to the
wooden skid with the use of large staples. These
should first be removed to avoid scratching the unit
when lifting off the crate.
Bumper strips are secured to the back of Roll-In mod-
els with thumb screws. Loosen these and make them
finger-tight to conform with the requirements of the
National Sanitation Foundation (NSF).
Most exterior stainless steel surfaces have a protec-
tive vinyl covering to prevent scratching during manu-
facturing, shipping and installation. After the unit is
installed in place of service, remove and discard the
covering from all surfaces.
III. d - WIRING DIAGRAM:
Refer to the wiring diagram on page 6 for any service
work performed on the unit.
To remove the wooden pallet, first if at all possible, we
suggest that the cabinet remain bolted to the pallet
during all transportation to the point of final installa-
tion. The bolts can then be removed with a 3/4” socket
wrench. Avoid laying the unit on its front, side or
back for removal of the pallet.
III. e - POWER SUPPLY:
The supply voltage should be checked prior to con-
nection to be certain that proper voltage for the cabi-
net wiring is available (refer to the serial tag to deter-
mine correct unit voltage). Make connections in ac-
cordance with local electrical codes. Use qualified
electricians.
NOTE: Traulsen does not recommend laying the unit
down on its front, side or back. However, if you must
please be certain to allow the unit to remain in an up-
right position afterwards for 24 hours before plugging
it in so that the compressor oils and refrigerant may
settle.
Use of a separate, dedicated circuit is required. Size
wiring to handle indicated load and provide necessary
overcurrent protector in circuit (see amperage require-
ments on the unit’s serial tag).
-2-
Download from Www.Somanuals.com. All Manuals Search And Download.
III. INSTALLATION (continued)
IV. CARE & MAINTENANCE (cont’d)
III. f - CLEARANCE:
IV. d - REPLACING THE GASKETS:
In order to assure optimum performance, your
Traulsen unit MUST have an adequate supply of air to
function properly. Therefore, the operating location
must either have a minimum of 12” clearance over-
head of the unit or allow for unrestricted air flow at
the back of the unit. Clearance of at least 12” above
is required in order to perform certain maintenance
tasks.
To remove the gasket to be replaced, grasp it firmly
by one corner and pull it out. Before attempting to
install a new gasket, both the unit and the gasket it-
self must be at room temperature. Insert the four cor-
ners first by using a rubber mallet (or hammer with a
block of wood). After the corners are properly inserted,
work your way towards the center from both ends by
gently hitting with a mallet until the gasket is com-
pletely seated in place (see figure 2 for proper gasket
placement).
IV. CARE & MAINTENANCE
Inside Door Panel
WARNING: DISCONNECT ELECTRICAL POWER
SUPPLY BEFORE CLEANING ANY PARTS OF THE
UNIT.
Gasket Assembly
Fig. 2
Vertical Gasket
IV. a - CLEANING THE EXTERIOR:
Exterior stainless steel should be cleaned with warm
water, mild soap and a soft cloth. Apply with a damp-
ened cloth and wipe in the direction of the metal grain.
NOTE: The gasket may appear too large, but if it is
installed as indicated above it will slip into place.
Avoid the use of strong detergents and gritty, abra-
sive cleaners as they may tend to mar and scratch
the surface. Do NOT use cleansers containing chlo-
rine, this may promote corrosion of the stainless steel.
V. OTHER
V. a - SERVICE INFORMATION:
Before calling for service, please check the following:
Care should also be taken to avoid splashing the unit
with water, containing chlorinated cleansers, when
mopping the floor around the unit.
Is the power supply ON?
Is the fuse OK or circuit breaker on?
Is the power switch “ON”?
For stubborn odor spills, use baking soda and water
(mixed to a 1 TBSP baking soda to 1 pint water ratio).
IV. b - CLEANING THE INTERIOR:
If after checking the above items and the unit is still
not operating properly, please contact an authorized
Traulsen service agent. A complete list of authorized
service agents was provided along with your Traulsen
unit. If you cannot locate this, you may also obtain
the name of a service agent from the Tech Service page
For cleaning both stainless steel and anodized alumi-
num interiors, the use of baking soda as described in
section “IV. d” is recommended. Use on breaker strips
as well as door gaskets. All interior fittings are re-
movable without tools to facilitate cleaning.
IV. c - HINGE REPLACEMENT:
Both the door and hinge can be easily removed from
the cabinet. To remove the door, remove the plug at
the bottom of the top hinge. Inside the hinge there is
a small screw which secures the door in place. Re-
move this with a flat head screwdriver and the door
can then be lifted off the hinge. To remove the door
portion of the hinge from the door, lift off the hinge
cover and then remove the three Phillips head screws
which secure the hinge in place on the door. To re-
move the cabinet portion of the hinge, remove the
three Phillips head screws which hold it in place. On
solid door units, the top hinge(s) contains a
microswitch for controlling the interior lighting.
If service is not satisfactory, please contact our in-
house service department at:
Traulsen & Co., Inc.
4401 Blue Mound Road
Fort Worth, TX 76106
(800) 825-8220
Traulsen & Co., Inc. reserves the right to change speci-
fications or discontinue models without notice.
To reassemble the hinge reverse the previous proce-
dure.
-3-
Download from Www.Somanuals.com. All Manuals Search And Download.
V. OTHER (cont’d)
V. b - SPARE PARTS:
V. d - INTERIOR ARRANGEMENTS:
Spare or replacement parts may be obtained through
a parts supplier or one of our authorized service
agents. A complete list of authorized service agents
accompanies this manual and is also posted on our
Traulsen proofer and proofer retarder models are de-
signed to accommodate roll-in bakery racks. See be-
low for size and capacities.
Model RPP232L-FHS can accommodate two (2) stan-
dard 18” x 26” pan racks. Maximum rack size with
wheels inboard of frame is 27” wide by 29” deep by
66” high.
V. c - WARRANTY REGISTRATION:
For your convenience, the warranties on your new
Traulsen unit may be registered with us by one of two
methods. Completing the enclosed warranty card
(shipped with the unit), or by filling out the on-line
warranty registration form located on the Technical
Service page of our website (www.traulsen.com).
VI. PIZZA PROOFER OPERATION
VI. a - CONTROLS:— Proof Box (see fig. 3)
VI. b - ON/OFF SWITCH:
Turns the Proofer
Control ON or OFF.
Fig. 3
TEMP normally displays the Set-Point temperature. For this unit, the temperature
is pre-set and fixed at 95°F. Contact the factory for adjustment. To display the
VIEW
actual cabinet temperature, press and hold
.
TIMER displays the minutes remaining [zero (0) indicates not in use].
SET
To set the Time, press and hold
or to Decrease.
To start the Timer, press
while using
to Increase
STOP
START
. The Time (minutes) displays and begins
flashing as it counts down. When the Timer reaches zero (0), a beeper
SET
sounds for 30 seconds. To stop the beeper, press
. Some units
STOP
may have both a LEFT and RIGHT Timer. They operate independently
and are set and operated as noted above.
VI. c - PROOFING:
The proofing process promotes yeast fermentation which generates gas and causes the dough to rise.
Proofing takes approximately 90 minutes depending on the product. A temperature setting of 95°F is
typical but will vary slightly depending on the product being proofed.
-4-
Download from Www.Somanuals.com. All Manuals Search And Download.
VII. TROUBLE SHOOTING GUIDE
FIND YOUR PROBLEM HERE
REMEDY
Check power supply.
1. Unit fails to start.
a.
2. Condensing unit operates for
prolonged periods or continuously.
a.
b.
c.
d.
Are doors closing properly?
Dirty condenser or filter. Clean properly.
Evaporator coil iced. Needs to defrost.
Shortage of refrigerant, call service.
3. Food compartment is too warm.
a.
b.
Check door(s) and gasket(s) for proper seal
Perhaps a large quantity of warm food has
recently been added or the door was kept
open for a long period of time, in both
cases, allow adequate time for the cabinet
to recover its normal operating temperature.
4. Food compartment is too cold.
a.
Perhaps a large quantity of very cold or frozen
food has recently been added. Allow adequate
time for the cabinet to recover its normal operating
temperature.
5. Condensation on the exterior surface.
6. Compressor hums but does not start.
a.
b.
Check door alignment and gaskets for proper seal.
Condensation on the exterior surface of the
unit is perfectly normal during periods of
high humidity.
a.
Call for service.
-5-
Download from Www.Somanuals.com. All Manuals Search And Download.
VIII. WIRING DIAGRAM
-6-
Download from Www.Somanuals.com. All Manuals Search And Download.
IX. WARRANTY INFORMATION
STANDARD DOMESTIC WARRANTY
TRAULSEN & CO., INC. warrants new equipment to the original purchaser, when installed within the United States against
defective material and workmanship for one (1) year from the date of original installation. Under this warranty, TRAULSEN
& CO., INC. will repair or replace, at its option, including service and labor, all parts found to be defective and subject to
this warranty. The compressor part is warranted for an additional four (4) years. During this period TRAULSEN & CO.,
INC. will supply replacement compressor(s) if deemed defective, however, all installation, recharging and repair costs
will remain the responsibility of the owner.
This warranty does not apply to damage resulting from fire, water, burglary, accident, abuse, misuse, transit, acts of
God, terrorism, attempted repairs, improper installation by unauthorized persons, and will not apply to food loss.
THERE ARE NO ORAL, STATUTORY OR IMPLIED WARRANTIES APPLICABLE TO TRAULSEN, INCLUDING BUT NOT LIM-
ITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE WHICH EX-
TEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. TRAULSEN SHALLHAVE NO OBLIGATION OR LIABILITY FOR
CONSEQUENTIAL OR SPECIAL DAMAGES, GROWING OUT OF OR WITH RESPECT TO THE EQUIPMENT OR ITS SALE,
OPERATION OR USE, AND TRAULSEN NEITHER ASSUMES NOR AUTHORIZES ANYONE ELSE TO ASSUME FOR IT ANY
OBLIGATION OR LIABILITY IN CONNECTION WITH THE EQUIPMENT OR ITS SALE, OPERATION OR USE OTHER THAN
AS STATED HEREIN.
INTERNATIONAL COMMERCIAL WARRANTY
(for Canadian warranties see domestic US warranty)
TRAULSEN & CO., INC. warrants to the original purchaser the Refrigeration Equipment manufactured and sold by it to be free
from defects in material and workmanship under normal use and service for a period of one (1) year from date of shipment. Under
this warranty, TRAULSEN & CO., INC. will reimburse the purchaser for the replacement of any part of said equipment (excluding
dryers & refrigerant gas) which then proves to be defective. This warranty does not apply to damage resulting from fire,
water, burglary, accident, abuse, misuse, transit, acts of God, terrorism, attempted repairs, improper installation by
unauthorized persons, and will not apply to food loss.
TRAULSEN’S standard warranty does not apply to Export Sales. Rather, for a period of one (1) year from date of original
installation not to exceed Fifteen (15) months from date of shipment from factory, TRAULSEN:
will replace, F.O.B. factory, any defective parts normally subject to warranty.
will not cover the cost of packing, freight or labor such costs being the sole responsibility of the dealer.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EITHER EXPRESSED OR IMPLIED AND CONSTITUTES
TRAULSEN’S FULL OBLIGATION AND LIABILITY. WARRANTIES NOT AVAILABLE ON REMOTE MODELS.
HOURS OF OPERATION:
Monday thru Friday 7:30 am - 4:30 pm CST
Traulsen & Co., Inc.
4401 Blue Mound Road Fort Worth, TX 76106
Phone: (800) 825-8220 Fax-Svce: (817) 740-6757
Quality Refrigeration
-7-
Download from Www.Somanuals.com. All Manuals Search And Download.
|