Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Notice...........................................................................................................................................1
FCC Warning...............................................................................................................................1
CE Mark Warning ........................................................................................................................1
Introduction ...................................................................................................................................1
Features.......................................................................................................................................1
Package Contents .......................................................................................................................2
Hardware Description ...................................................................................................................3
Physical Dimension......................................................................................................................3
Front Panel ..................................................................................................................................3
Reset Button..........................................................................................................................3
Bottom View.................................................................................................................................4
DIP-switch....................................................................................................................................4
LED Indicators .............................................................................................................................5
Ports ............................................................................................................................................6
Cabling.........................................................................................................................................8
Wiring the Power Inputs...............................................................................................................8
Wiring the Fault Alarm Contact....................................................................................................8
Wiring the Fault Alarm Contact....................................................................................................9
Mounting Installation .................................................................................................................. 10
DIN-Rail Mounting ..................................................................................................................... 10
Wall Mount Plate Mounting........................................................................................................ 11
Hardware Installation.................................................................................................................. 11
Hardware Installation.................................................................................................................. 12
Installation Steps ....................................................................................................................... 12
Network Application.................................................................................................................... 13
X-Ring Application ..................................................................................................................... 14
Coupling Ring Application.......................................................................................................... 15
Dual Homing Application............................................................................................................ 15
Web-Based Management............................................................................................................ 16
About Web-based Management ................................................................................................ 16
Preparing for Web Management................................................................................................ 16
System Login............................................................................................................................. 16
Download from Www.Somanuals.com. All Manuals Search And Download.
Port status.................................................................................................................................. 17
Single Port Information ........................................................................................................ 18
Port Statistics............................................................................................................................. 18
Port Control................................................................................................................................ 19
Switch Setting............................................................................................................................ 19
Port Mirroring............................................................................................................................. 20
VLAN configuration.................................................................................................................... 21
Port-based VLAN................................................................................................................. 22
802.1Q VLAN....................................................................................................................... 23
802.1Q VLAN....................................................................................................................... 24
Alert ........................................................................................................................................... 27
Email Alert Configuration ..................................................................................................... 27
Event Configuration ............................................................................................................. 28
Power Alarm Configuration.................................................................................................. 29
IP Configuration......................................................................................................................... 29
SNTP Configuration................................................................................................................... 30
IP Security ................................................................................................................................. 32
RSTP Configuration................................................................................................................... 32
System Configuration........................................................................................................... 33
Per Port Configuration ......................................................................................................... 34
X-Ring........................................................................................................................................ 35
QoS Configuration ..................................................................................................................... 37
IGMP.......................................................................................................................................... 38
Security Manager....................................................................................................................... 39
SNMP Configuration .................................................................................................................. 40
System Options.................................................................................................................... 41
Community strings ............................................................................................................... 41
Trap Manager ...................................................................................................................... 41
Configuration Backup................................................................................................................. 41
TFTP Restore Configuration................................................................................................ 41
TFTP Backup Configuration................................................................................................. 42
TFTP Update Firmware ............................................................................................................. 42
Factory Default .......................................................................................................................... 43
System Reboot .......................................................................................................................... 43
Download from Www.Somanuals.com. All Manuals Search And Download.
Save Configuration .................................................................................................................... 44
Rate Control............................................................................................................................... 44
System Log................................................................................................................................ 45
System Log Configuration.................................................................................................... 45
Event Configuration ............................................................................................................. 46
Troubles shooting....................................................................................................................... 48
Technical Specification............................................................................................................... 49
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
The SISTM10xx-162-LRx Managed Industrial Switch is a cost-effective solution and meets the high
reliability requirements demanded by industrial applications. The switch can be easily managed
through the Web GUI. By using fiber port can extend the connection distance that increases the
network elasticity and performance. It also provides the X-Ring function that can prevent the network
connection failure.
Features
•
•
•
•
•
•
•
•
•
•
•
Conform to IEEE 802.3 10Base-T, 802.3u 100Base-TX/100Base-FX
6-port 10/100TX plus 2 100FX port industrial switch
RJ-45 port support auto MDI/MDI-X function
Store-and-Forward switching architecture
Wide-range redundant power design
DIN rail and wall mount design
2K MAC address table
Web management GUI
Per port supports 4 priority queues
Provides Fiber link ability
IEEE 802.3x flow control support
o
o
Flow control with full-duplex
Back pressure with half-duplex
•
•
•
•
•
•
•
•
•
•
•
Support Class of service
Support IGMP with Query mode for multi media application
Supports ingress packet filter and egress rate limit.
Support SNTP/SMTP
Port mirror for TX or TX and RX packet.
Alarm Relay output for system events
Support X-Ring function
Power polarity reverse protect
1Mbits Embedded memory
Support Port based VLAN / 802.1 Q Tag VLAN
IEEE 802.1p class of service and provide port base, Tag base and Type of service priority
method
•
•
•
Support DHCP client
SNMP, Web Management, RMON supported
TFTP firmware update and system configure restore and backup
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Package Contents
Please refer to the package content list below to verify them against the checklist.
•
•
•
•
•
SISTM10xx-162-LRx Managed Industrial Switch
DC Jack ꢀ2.0/150mm RoHS
User manual CD
DIN-Rail Bracket (attached on the switch)
One wall mount plate and six screws
SISTM10xx-162-LRx
DC Jack ꢀ2.0/150mm RoHS
User Manual CD
Wall Mount Plate
Screws
DIN-Rail Bracket (installed)
Compare the contents of the industrial switch with the standard checklist above. If any item is
damaged or missing, please contact Transition Networks.
2
Download from Www.Somanuals.com. All Manuals Search And Download.
Hardware Description
In this paragraph, it will describe the Industrial switch’s hardware spec, port, cabling information, and
wiring installation.
Physical Dimension
54mm (w) x 135mm (h) x 105mm (d)
Front Panel
The Front Panel of the SISTM10xx-162-LRx Managed Industrial Switch is shown below:
Reset Button
The reset button provides user a quick and easy way to restart and set the configuration back to
default value.
•
•
Restart: press the button for 2 seconds and release
Set to factory default value: press the button for 5 seconds and release. The switch will
3
Download from Www.Somanuals.com. All Manuals Search And Download.
set all configurations back to default setting
Bottom View
The bottom view of the switch is shown below:
Grounding Screw
6-position terminal block
Primary power input terminals (2)
Contact relay output terminals (2)
Secondary power input
DIP-switch
The switch provides the 9 DIP-switch for configuring the relay alarm operation mode and the master
ring operation mode. The default value of Dipswitch is OFF.
DIP Switch No
Status
Description
OFF
Disable port 1 Alarm
1
Enable port Alarm. If the port’s link fails, the fault
LED will light up
ON
OFF
ON
Disable port Alarm
2
3
4
Enable port Alarm. If the port’s link fails, the fault
LED will light up
OFF
ON
Disable port Alarm
Enable port Alarm. If the port’s link fails, the fault
LED will light up
OFF
ON
Disable port Alarm
Enable port Alarm. If the port’s link fails, the fault
LED will light up
4
Download from Www.Somanuals.com. All Manuals Search And Download.
OFF
ON
Disable port Alarm
5
6
Enable port Alarm. If the port’s link fails, the fault
LED will light up
OFF
ON
Disable port Alarm
Enable port Alarm. If the port’s link fails, the fault
LED will light up
OFF
ON
Disable port Alarm
7
8
9
Enable port Alarm. If the port’s link fails, the fault
LED will light up
OFF
ON
Disable port Alarm
Enable port Alarm. If the port’s link fails, the fault
LED will light up
OFF
ON
Disable the ring master function
Enable the switch as the ring master in the X-Ring
group
[NOTE]
1.
When port alarm function is enabled, the fault LED will on and Alarm relay will activity when
port failure occurs.
2.
Please restart the switch after the X-Ring DIP switch is set.
LED Indicators
There are 7 diagnostic LEDs located on the front panel of the industrial switch. They provide real-
time information of system and optional status. The following table provides description of the LED
status and their meanings for the switch.
LED
Status
Meaning
Green
Off
The switch unit is power on
The switch unit is no power input
Power on
Power
Green
Off
Power 1
Power 2
No power inputs
Green
Power on
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Off
No power inputs
Power failure or UTP port failure or Fiber port
failure
Yellow
Fault
No Power failure or UTP port failure or Fiber port
failure occurs
Off
The industrial switch is the master of X-Ring
group
Green
R.M. (Ring Master)
The industrial switch is not a ring master in X-
Ring group
Off
Green
Blinks
The port is linking
LNK/ACT
The port is transmitting or receiving packets
from the TX device
(Fiber port)
Off
No device attached
Yellow
Blinks
The port is operating in full-duplex mode
Collision of Packets occurs in the port
FDX/COL
(Fiber Port)
The port in half-duplex mode or no device
attached
Off
Ports
RJ-45 ports
There are 6x 10/100Mbps auto-sensing ports for 10Base-T or 100Base-TX devices connection. The
UTP ports will auto-sense for 10Base-T or 100Base-TX connections. Auto MDI/MDIX means that the
switch can connect to another switch or workstation without changing straight through or crossover
cabling. See the below figures for straight through and crossover cable schematic.
RJ-45 Pin Assignments
Pin Number
Assignment
1
2
3
6
Tx+
Tx-
Rx+
Rx-
[NOTE] “+” and “-” signs represent the polarity of the wires that make up each wire pair.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
All ports on this industrial switch support automatic MDI/MDI-X operation, user can use straight-
through cables (See figure below) for all network connections to PCs or servers, or to other switches
or hubs. In straight-through cable, pins 1, 2, 3, and 6, at one end of the cable, are connected straight
through to pins 1, 2, 3 and 6 at the other end of the cable. The table below shows the 10BASE-
T/100BASE-TX MDI and MDI-X port pin outs.
Pin MDI-X
Signal Name
MDI Signal Name
1
2
3
6
Receive Data plus (RD+)
Receive Data minus (RD-)
Transmit Data plus (TD+)
Transmit Data minus (TD-)
Transmit Data plus (TD+)
Transmit Data minus (TD-)
Receive Data plus (RD+)
Receive Data minus (RD-)
Straight Through Cable Schematic
Cross Over Cable Schematic
Fiber Port
There are two 100Base-FX ports. The fiber port is ST type connector in multi mode (2Km) or single
mode (30Km).
7
Download from Www.Somanuals.com. All Manuals Search And Download.
ATTENTION
This is a Class 1 Laser/LED product. Don’t stare into the Laser/LED Beam.
Cabling
•
Using four twisted-pair, Category 5 cabling for RJ-45 port connection. The cable between the
converter and the link partner (switch, hub, workstation, etc.) must be less than 100 meters (328
ft.) long.
•
•
Fiber segment using single-mode connector type must use 9/125 um single-mode fiber cable.
User can connect two devices in the distance up to 30 Kilometers.
Fiber segment using multi-mode connector type must use 50 or 62.5/125 um multi-mode fiber
cable. User can connect two devices up to 2Km distances.
Wiring the Power Inputs
Please follow below steps to insert the power wire.
V- V+
V- V+
1. Insert the positive and negative wires into the V+ and V- connector on the
terminal block connector.
2. To tighten the wire-clamp screws for preventing the DC wires to loose.
[NOTE] The wire range of terminal block is from 12~ 24 AWG.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Wiring the Fault Alarm Contact
The fault alarm contact is in the middle of terminal block connector as below figure shows. By
inserting the wires and set the DIP switch at “ON” status, it will detect the fault status which the
power is failure or port link failure and form an open circuit. And, application example for the fault
alarm contact as below:
Insert the wires into the fault alarm contact
[NOTE] The wire range of terminal block is from 12~ 24 AWG.
Fault Alarm Contact
The open circuit will form when the
power failure or port link failure.
24V DC Buzzer
24V Battery
The fault alarm device will send a
warning signal to warn the user, ex:
alarm sound or flash light.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Mounting Installation
DIN-Rail Mounting
The DIN-Rail is screwed on the industrial switch when out of factory.
1.
First, insert the top of DIN-Rail into the track.
2.
Then, lightly push the DIN-Rail into the track.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
3.
4.
Check the DIN-Rail is tightly on the track.
To remove the industrial switch from the track, reverse steps above.
Wall Mount Plate Mounting
Follow the below steps to mount the industrial switch with wall mount plate.
1. Remove the DIN-Rail from the industrial switch; loose the screws to remove the DIN-Rail.
2. Place the wall mount plate on the rear panel of the industrial switch.
3. Use the screws to screw the wall mount plate on the industrial switch.
4. Use the hook holes at the corners of the wall mount plate to hang the industrial switch on
the wall.
5. To remove the wall mount plate, reverse steps above.
Screwing the wall mount plate on the Industrial media converter
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Hardware Installation
Installation Steps
1. Unpacking the Industrial switch
2. Check the DIN-Rail is screwed on the Industrial switch. If the DIN-Rail is not screwed on the
Industrial switch. Please refer to DIN-Rail Mounting section for DIN-Rail installation. If user
want to wall mount the Industrial switch, then please refer to Wall Mount Plate Mounting
section for wall mount plate installation.
3. To hang the Industrial switch on the DIN-Rail track or wall, please refer to the Mounting
Installation section.
4. Power on the Industrial switch. How to wire the power; please refer to the Wiring the Power
Inputs section. The power LED on the Industrial switch will light up. Please refer to the LED
Indicators section for meaning of LED lights.
5. Prepare the twisted-pair, straight through Category 5 cable for Ethernet connection.
6. Insert one side of RJ-45 cable (category 5) into the Industrial switch Ethernet port (RJ-45 port)
and another side of RJ-45 cable (category 5) to the network devices’ Ethernet port (RJ-45 port),
ex: Switch PC or Server. The UTP port (RJ-45) LED on the Industrial switch will light up when
the cable connected with the network device. Please refer to the LED Indicators section for
LED light meaning.
[NOTE] Be sure the connected network devices support MDI/MDI-X. If it does not support then
use the crossover category-5 cable.
7. When all connections are all set and LED lights all show in normal, the installation is complete.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Network Application
This chapter provides some sample applications to help user to have more actual idea of industrial
switch function application. A sample application of the industrial switch is as below:
13
Download from Www.Somanuals.com. All Manuals Search And Download.
X-Ring Application
The industrial switch supports the X-Ring protocol that can help the network system to recovery from
network connection failure within 300ms or less, and make the network system more reliable. The X-
Ring algorithm is like as spanning tree protocol (STP) algorithm but it has faster recovery time than
STP. The following figure is a sample X-Ring application.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Coupling Ring Application
In the network, it may have more than one X-Ring group. By using the coupling ring function can
connect each X-Ring for the redundant backup. It can ensure the transmissions between two ring
groups will no failure. The following figure is a sample of coupling ring application.
Dual Homing Application
Dual Homing function is to prevent a lost connection between X-Ring group and upper level/core
switch. Assign two ports to be the Dual Homing port that is backup port in the X-Ring group. The
Dual Homing function only works when the X-Ring function is active. Each X-Ring group only has
one Dual Homing port.
[NOTE] In Dual Homing application architecture, the upper level switches need to enable the Rapid
Spanning Tree protocol.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Web-Based Management
About Web-based Management
On CPU board of the switch there is an embedded HTML web site residing in flash memory, which
offers advanced management features and allow users to manage the switch from anywhere on the
network through a standard browser such as Microsoft Internet Explorer.
The Web-Based Management supports Internet Explorer 6.0. And, it is applied for Java Applets for
reducing network bandwidth consumption, enhance access speed and present an easy viewing
screen.
Preparing for Web Management
Before to use web management, install the industrial switch on the network and make sure that any
one of PC on the network can connect with the industrial switch through the web browser. The
industrial switch default value of IP, subnet mask, username and password is as below:
•
•
•
•
•
IP Address: 192.168.16.1
Subnet Mask: 255.255.255.0
Default Gateway: 192.168.16.254
User Name: root
Password: root
System Login
1.
2.
3.
4.
5.
Launch the Internet Explorer on the PC
The login screen will appear right after
Key in the user name and password. The default user name and password as “root”
Press “Enter” or ”OK”, and then the home screen of the Web-based management appears as
below:
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Function Menu Bar
Home Interface
Panel Figure Display
Configuration Display Screen
Port status
View every port status that depended on user’s setting and the negotiation result
•
•
•
•
•
Port: The port number
Type: The speed mode, ex: 100TX = 100Mbps
Link: “Down” means “No Link”. “UP” is for “Link”
State: Display port statuses “disable” or “enable”. “Unlink” will be treated as “off”
Negotiation: Display the auto negotiation mode: auto/force. “Config” means the value that
user configured. “Actual” means the current value of the port
•
•
Speed Duplex: Display port connection speed. “Config” means the value that user
configured. “Actual” means the current value of the port
Flow Control: Display the flow control status is “enable” or “disable” in full mode. “Config”
means the value that user configured. “Actual” is for the current value of the port
Port Status interface
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Single Port Information
Click the port on the Panel figure on the web interface directly. Then, the single port information
window will show up and display the port current information.
Port information interface
Port Statistics
The following information provides the current port statistic information
¢
Click Clear button to clean all counts
Port Statistics Interface
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Port Control
Change the port status
•
•
•
Select the port by scroll the Port column
State: Disable or enable control of this port
Negotiation: Set auto negotiation mode is Auto, Nway (specify the speed/duplex on this
port and enable auto-negotiation), or Force
•
•
•
Speed: Set the speed of the port
Duplex: Set full-duplex or half-duplex mode of the port
Flow control: Set flow control function is Symmetric or Asymmetric in Full Duplex mode.
The default value is Disable
And then, click Apply button to apply all configuration
•
•
When user select the port, user can see port current configure shows in below column
Port Control interface
Switch Setting
Assigning the system name, location and view the system information
•
•
•
•
•
•
System Name: Assign the name of switch. The maximum length is 64 bytes
System Description: Display the description of switch. Read only cannot be modified
System Location: Assign the switch physical location. The maximum length is 64 bytes
System Contact: Enter the name of contact person or organization
Firmware Version: Display the switch’s firmware version
Kernel Version: Display the kernel software version
19
Download from Www.Somanuals.com. All Manuals Search And Download.
•
•
Hardware version: Display the switch hardware version
MAC Address: Display the unique hardware address assigned by manufacturer (default)
Switch settings interface
[NOTE] Remember to execute the “Save Configuration” action, otherwise the new configuration will
lose when switch power off.
Port Mirroring
The Port mirroring is a method for monitor traffic in switched networks. Traffic through ports can be
monitored by one specific port. That is, traffic goes in or out monitored ports will be duplicated into
mirror port.
•
•
•
Port Mirroring Mode: Set mirror mode -- Disable, TX, and Both. The default value is
“Disable”
Analysis Port: It means mirror port can be used to see all monitor port traffic. User can
connect mirror port to LAN analyzer or Netxray
Monitor Port: The ports user wants to monitor. All monitor port traffic will be copied to
mirror port. User can select max 7 monitor ports in the switch. User can choose which port
that wants to monitor in only one mirror mode. Mark the State check box to select the port
And then, click Apply
•
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Port Mirroring interface
[NOTE]
1.
2.
Select the monitor mode as disable to disable the mirroring
Remember to execute the “Save Configuration” action, otherwise the new configuration
will lose when switch power off.
VLAN configuration
A Virtual LAN (VLAN) is a logical network grouping that limits the broadcast domain, which would,
allow you to isolate network traffic so only the members of the VLAN will receive traffic from the
same members of VLAN. Basically, creating a VLAN from a switch is logically equivalent of
reconnecting a group of network devices to another Layer 2 switch. However, all the network
devices are still plugged into the same switch physically.
The industrial switch supports port-based and 802.1Q (tagged-based) VLAN. In the default
configuration, VLAN operation mode default is “Disable”.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
VLAN Configuration interface
Port-based VLAN
Packets can go among only members of the same VLAN group. Note all unselected ports are
treated as belonging to another single VLAN. If the port-based VLAN enabled, the VLAN-tagging is
ignored.
In order for an end station to send packets to different VLAN groups, it itself has to be either capable
of tagging packets it sends with VLAN tags or attached to a VLAN-aware bridge that is capable of
classifying and tagging the packet with different VLAN ID based on not only default PVID but also
other information about the packet, such as the protocol.
VLAN – PortBase interface
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Add
Click
to add a new VLAN group(The maximum VLAN group is up to 64 VLAN
•
groups)
Entering the VLAN name, group ID and grouping the members of VLAN group
•
•
Apply
And then, click
VLAN—PortBase Add interface
•
•
The VLAN group will list
Next Page
button
Delete
To view the another VLAN groups, click
To delete unwanted VLAN, click
•
•
Edit
To modify existing VLAN group, press
button
[NOTE] Remember to execute the “Save Configuration” action, otherwise the new configuration will
lose when switch power off.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
802.1Q VLAN
Tagged-based VLAN is an IEEE 802.1Q specification standard which it allows to create a VLAN
across devices from different switch venders. IEEE 802.1Q VLAN uses a technique to insert a “tag”
into the Ethernet frames. Tag contains a VLAN Identifier (VID) that indicates the VLAN numbers.
All ports on the switch belong to default VLAN, VID is 1. The default VLAN can’t be deleting. The
maximum VLAN group is up to 64 VLAN groups.
802.1q VLAN interface
Basic VLAN
Click Add button
•
Management VLAN ID: It is used for Remote Management Security. In fact, it can
•
remote management that includes telnet, SNMP, and Web browse the switch, only
when the port of VLAN group ID is equal to the Management VLAN ID. Fill the
specific VLAN ID number in Management VLAN ID column and mark the check box,
Apply
and then click
button to enable the function. For example: the
management VLAN ID is 101, the VLAN group ID 101 includes the port 1, 2, and 4.
Therefore, only port 1, 2, and 4 can remote management the switch. And, if the port is
in two different VLAN groups and one of VLAN group ID is equal to the assigned
Management VLAN ID, it still has the right to remote management the switch.
Group Name: Assign a name for the new VLAN
•
•
VLAN ID: Key in a VLAN ID (2~4094). The default is 1
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Grouping the ports and click
button
•
Add
802.1q VLAN –Add interface
And then, click
then follow interface as below.
•
Next
25
Download from Www.Somanuals.com. All Manuals Search And Download.
¢
Click Apply to set the outgoing frames are VLAN-Tagged frames or untagged
‹
‹
Tag: Outgoing frames with VLAN-Tagged
Untag: Outgoing frames without VLAN-Tagged
Port VLAN ID
Configure port VID settings
•
•
•
Port VLAN ID: Enter the port VLAN ID
And then, click Apply
To reset back to default value, click
button
•
Default
802.1q VLAN – Port VLAN ID interface
[NOTE] Remember to execute the “Save Configuration” action, otherwise the new configuration will
lose when switch power off.
26
Download from Www.Somanuals.com. All Manuals Search And Download.
Alert
There are three kinds of alert – e-mail, event, and power alarm for user to configure.
Email Alert Configuration
When the specific events occur, the system will send the alert to the email account that is assigned
by user. User can set up the mail server IP, mail account, and forwarded email account for receiving
the event alert.
¢
¢
¢
Email Alert: To enable or disable the email alert function
SMTP Server IP Address: Set up the mail server IP address
Authentication: Mark the check box to enable and configure the email account and password
for authentication
‹
The email account must exist on the mail server, which user had set up in SMTP Server
IP Address column
‹
‹
Password: The email account password
Confirm Password: Re-confirm the password
¢
¢
E-mail Address of Receipient 1 ~ 4: Assign up to 4 e-mail accounts also to receive the alert
Apply
And then, click
Email Alert Configuration interface
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Event Configuration
The selected events that occur will send out the alert to the assigned SMTP server. Also, user can
select port events for alerting.
•
System event selection: 4 selections – Device cold start, Power status, SNMP Authentication
Failure, and X-Ring topology changes. Mark the checkbox to select the event. When selected
events occur, the system will sent out the alerting
‹
‹
‹
‹
Device cold start: When the device executes cold start action, the system will send out
the alert to the dedicate SMTP server
Power status: When the device power status has changed, the system will send out the
alert to the dedicate SMTP server
SMNP Authentication Failure: When the SNMP authentication fail, the system will
send out the alert to the dedicate SMTP server
X-Ring topology change: When the X-Ring topology has changed, the system will
send out the alert to dedicate SMTP server
•
Port event selection: Select the per port events. Per port has 3 selections – Link UP, Link
Down, and Link UP & Link Down. Disable means no event is selected
‹
‹
Link UP: The system will send out an alert when port connection is up only
Link Down: The system will send out an alert message when port connection is down
only
‹
Link UP & Link Down: The system will send out an alert message when port
connection is up and down
Apply
After selected, click
•
Event Configuration interface
28
Download from Www.Somanuals.com. All Manuals Search And Download.
Power Alarm Configuration
Power alarm function enables the Relay alarm action. Without enabling power alarm function, the
Relay alarm action will not work even the Relay alarm is set.
Mark the check box and click Apply button
•
Power Alarm interface
IP Configuration
User can configure the IP Settings and DHCP client function
•
DHCP Client: To enable or disable the DHCP client function. When DHCP client function is
enabling, the industrial switch will be assigned the IP address from the network DHCP server.
The default IP address will be replace by the DHCP server assigned IP address. After user click
“Apply” button, a popup dialog show up. It is to inform the user that when the DHCP client is
enabling, the current IP will lose and user should find the new IP on the DHCP server. To cancel
the enabling DHCP client function, click “cancel”
•
IP Address: Assign the IP address that the network is using. If DHCP client function is enabling,
and then user don’t need to assign the IP address. And, the network DHCP server will assign
the IP address for the industrial switch and display in this column. The default IP is 192.168.16.1
•
Subnet Mask: Assign the subnet mask of the IP address. If DHCP client function is enabling,
and then user do not need to assign the subnet mask
•
•
Gateway: Assign the network gateway for the industrial switch. The default gateway is
192.168.16.254
Apply
And then, click
button
29
Download from Www.Somanuals.com. All Manuals Search And Download.
IP configuration interface
SNTP Configuration
User can configure the SNTP (Simple Network Time Protocol) settings. The SNTP allows user to
synchronize switch clocks in the Internet.
•
•
SNTP Client: To enable or disable SNTP function to get the time from the SNTP server
Daylight Saving Time: To enable or disable daylight saving time function. When daylight
saving time is enabling, user need to configure the daylight saving time period
•
UTC Timezone: Set the switch location time zone. The following table lists the different location
time zone for the reference. User also can drag down the list to find the time zone user want it.
Local Time Zone
Conversion from UTC
- 1 hour
Time at 12:00 UTC
November Time Zone
Oscar Time Zone
11am
10 am
9 am
-2 hours
ADT - Atlantic Daylight
AST - Atlantic Standard
EDT - Eastern Daylight
EST - Eastern Standard
CDT - Central Daylight
CST - Central Standard
MDT - Mountain Daylight
MST - Mountain Standard
PDT - Pacific Daylight
PST - Pacific Standard
ADT - Alaskan Daylight
ALA - Alaskan Standard
HAW - Hawaiian Standard
Nome, Alaska
-3 hours
-4 hours
-5 hours
-6 hours
-7 hours
-8 hours
8 am
7 am
6 am
5 am
4 am
-9 hours
3 am
2 am
1 am
-10 hours
-11 hours
CET - Central European
FWT - French Winter
MET - Middle European
+1 hour
1 pm
30
Download from Www.Somanuals.com. All Manuals Search And Download.
MEWT - Middle European Winter
SWT - Swedish Winter
EET - Eastern European, USSR Zone 1
BT - Baghdad, USSR Zone 2
ZP4 - USSR Zone 3
+2 hours
+3 hours
+4 hours
+5 hours
+6 hours
+7 hours
+8 hours
+9 hours
2 pm
3 pm
4 pm
5 pm
6 pm
7 pm
8 pm
9 pm
ZP5 - USSR Zone 4
ZP6 - USSR Zone 5
WAST - West Australian Standard
CCT - China Coast, USSR Zone 7
JST - Japan Standard, USSR Zone 8
EAST - East Australian Standard GST
Guam Standard, USSR Zone 9
IDLE - International Date Line
NZST - New Zealand Standard
NZT - New Zealand
+10 hours
10 pm
+12 hours
Midnight
•
•
•
SNTP Sever IP: Set the SNTP server IP address
Switch Timer: Display the switch current time
Daylight Saving Period: Set up the Daylight Saving beginning and ending time. Daylight
Saving beginning and ending time will be different in every year
•
•
Daylight Saving Offset (mins): Configure the offset value
Apply
And then, click
button
[NOTE] Remember to execute the “Save Configuration” action, otherwise the new configuration will
lose when switch power off.
SNTP Configuration
31
Download from Www.Somanuals.com. All Manuals Search And Download.
IP Security
IP security function allows user to assign 10 specific IP addresses that have permission to access
the switch through the web browser for the securing switch management.
•
•
Enable the IP Security: Mark the check box to enable the IP security function
Security IP 1 ~ 10: Assign up to 10 specific IP address. Only these 10 IP address can access
and manage the switch through the Web browser
Apply
And then, click
button to apply the configuration
•
[NOTE] Remember to execute the “Save Configuration” action, otherwise the new configuration will
lose when switch power off.
IP Security Interface
RSTP Configuration
The Rapid Spanning Tree Protocol (RSTP) is an evolution of the Spanning Tree Protocol and
provides for faster spanning tree convergence after a topology change. The system also supports
STP and the system will auto detect the connected device that is running STP or RSTP protocol.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
System Configuration
•
•
User can view spanning tree information about the Root Bridge
User can modify RSTP state. After modification, click Apply button
‹
‹
RSTP mode: user must enable or disable RSTP function before configure the related
parameters
Priority (0-61440): a value used to identify the root bridge. The bridge with the lowest
value has the highest priority and is selected as the root. If the value changes, user must
reboot the switch. The value must be multiple of 4096 according to the protocol standard
rule
‹
Max Age (6-40): the number of seconds a bridge waits without receiving Spanning-tree
Protocol configuration messages before attempting a reconfiguration. Enter a value
between 6 through 40
‹
‹
Hello Time (1-10): the time that controls switch sends out the BPDU packet to check
RSTP current status. Enter a value between 1 through 10
Forward Delay Time (4-30): the number of seconds a port waits before changing from its
Rapid Spanning-Tree Protocol learning and listening states to the forwarding state. Enter
a value between 4 through 30
[NOTE]
1.
Must follow the rule to configure the MAX Age, Hello Time, and Forward Delay
Time
2 x (Forward Delay Time value –1) > = Max Age value >= 2 x (Hello Time
value +1)
2.
Remember to execute the “Save Configuration” action, otherwise the new
configuration will lose when switch power off
33
Download from Www.Somanuals.com. All Manuals Search And Download.
RSTP– System Configuration Interface
Per Port Configuration
Configure path cost and priority of every port
•
•
Select the port in Port column
Path Cost: The cost of the path to the other bridge from this transmitting bridge at the specified
port. Enter a number 1 through 200000000
•
•
Priority: Decide which port should be blocked by priority in LAN. Enter a number 0 through 240.
The value of priority must be the multiple of 16
Admin P2P: Some of the rapid state transactions that are possible within RSTP are dependent
upon whether the port concerned can only be connected to exactly one other bridge (i.e. it is
served by a point-to-point LAN segment), or can be connected to two or more bridges (i.e. it is
served by a shared medium LAN segment). This function allows the P2P status of the link to be
manipulated administratively. True is P2P enabling. False is P2P disabling
Admin Edge: The port directly connected to end stations cannot create bridging loop in the
network. To configure the port as an edge port, set the port to “True” status
Admin Non Stp: The port includes the STP mathematic calculation. True is not including STP
mathematic calculation. False is including the STP mathematic calculation
•
•
Apply
And then, click
button
•
[NOTE] Remember to execute the “Save Configuration” action, otherwise the new configuration will
lose when switch power off.
34
Download from Www.Somanuals.com. All Manuals Search And Download.
RSTP – Per Port Configuration interface
X-Ring
X-Ring provides a faster redundant recovery than Spanning Tree topology. The action is similar with
STP or RSTP, but the algorithms not the same.
In the X-Ring topology, every switch should enable X-Ring function and assign two member ports in
the ring. Only one switch in the X-Ring group would be set as a backup switch that one of two
member ports would be blocking, called backup port, and another port is called working port. Other
switches are called working switches and their two member ports are called working ports. When the
network connection failure, the backup port will automatically become a working port to recovery the
failure.
The switch supports one Dipswitch for setting the switch as the ring master or slave mode. The ring
master has the rights to negotiate and place command to other switches in the X-Ring group. If
there are 2 or more switches are in master mode, then software will select the switch with lowest
MAC address number as the ring master. The X-Ring master ring mode will be enabling by the DIP
Switch. When the switch is set to the master ring mode, the X-Ring configuration interface will
display the switch as the master ring message. Also, user can identify the switch as the ring master
from the R.M. LED panel of the LED panel on the switch.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
The system also supports the coupling ring that can connect 2 or more X-Ring group for the
redundant backup function and dual homing function that prevent connection lose between X-Ring
group and upper level/core switch.
•
•
Enable X-Ring: To enable the X-Ring function. Marking the check box to enable the X-Ring
function.
1st & 2nd Working Ports: Assign two ports as the member ports. One port will be working
port and one port will be the backup port. The system will automatically decide which port is
working port and which port is backup port.
•
Enable Coupling Ring: To enable the coupling ring function. Marking the check box to
enable the coupling ring function.
•
•
•
Coupling port: Assign the member port.
Control port: Set the switch as the master switch in the coupling ring.
Enable Dual Homing: Set up one of port on the switch to be the Dual Homing port. In an
X-Ring group, maximum Dual Homing port is one. Dual Homing only work when the X-Ring
function enable.
Apply
And then, click
to apply the configuration.
•
X-Ring Interface
[NOTE]
1. When the X-Ring function enable, user must disable the RSTP. The X-Ring function and RSTP
function cannot exist at the same time.
2. Remember to execute the “Save Configuration” action, otherwise the new configuration will lose
when switch power off.
36
Download from Www.Somanuals.com. All Manuals Search And Download.
QoS Configuration
Configure Qos setting of the every port
•
Oos Policy: Select the Qos policy rule
‹
Using the 8,4,2,1 weight fair queue scheme: The switch will follow 8:4:2:1 rate to
process priority queue from Hi to lowest queue. For example: the system will
process 8 high queue packets, 4 middle queue packets, 2 low queue packets, and
the one lowest queue packets at the same time
‹
Use the strict priority scheme: The higher queue will always be process first,
except higher queue is empty
•
Priority Type: Every port has 5 priority type selections
‹
Port-base: The port priority will follow the default port priority that user have
assigned – High, middle, low, or lowest
‹
COS only: The port priority will only follow the COS priority that user have
assigned
‹
‹
TOS only: The port priority will only follow the TOS priority that user have assigned
COS first: The port priority will follow the COS priority first, and then other priority
rule
‹
TOS first: The port priority will follow the TOS priority first, and the other priority rule
•
•
COS priority: Set the COS priority level 0~7
TOS priority: The system provides 0~63 TOS priority level. Each level has 4 types of
priority – high, mid, low, and lowest. The default value is “Lowest” priority for each level.
When the IP packet is received, the system will check the TOS level value in the IP packet
has received. For example: user set the TOS level 25 is high. The port 1 is following the
TOS priority policy only. When the packet received by port 1, the system will check the TOS
value of the received IP packet. If the TOS value of received IP packet is 25(priority = high),
and then the packet priority will have highest priority.
[NOTE] QoS and Rate control cannot be existed at the same time.
37
Download from Www.Somanuals.com. All Manuals Search And Download.
QoS configuration Interface
IGMP
The Internet Group Management Protocol (IGMP) is an internal protocol of the Internet Protocol (IP)
suite. IP manages multicast traffic by using switches, routers, and hosts that support IGMP. Enabling
IGMP allows the ports to detect IGMP queries and report packets and manage IP multicast traffic
through the switch. IGMP have three fundamental types of message as follows:
38
Download from Www.Somanuals.com. All Manuals Search And Download.
Message
Query
Description
A message sent from the querier (IGMP router or switch) asking
for a response from each host belonging to the multicast group.
A message sent by a host to the querier to indicate that the host
wants to be or is a member of a given group indicated in the
report message.
Report
A message sent by a host to the querier to indicate that the host
has quit to be a member of a specific multicast group.
Leave Group
User can enable IGMP protocol and IGMP Query function in here. User will see the IGMP snooping
information in this section -- difference multicast group VID and member port, and IP multicast
addresses range from 224.0.0.0 through 239.255.255.255.
IGMP Snooping interface
[NOTE] Remember to execute the “Save Configuration” action, otherwise the new configuration will
lose when switch power off.
Security Manager
Change web management login user name and password for the management security issue
1.
2.
3.
User name: Key in the new user name(The default is “admin”)
Password: Key in the new password(The default is “admin”)
Confirm password: Re-type the new password
39
Download from Www.Somanuals.com. All Manuals Search And Download.
Apply
4.
And then, click
Security Manager interface
[NOTE] Remember to execute the “Save Configuration” action, otherwise the new configuration will
lose when switch power off.
SNMP Configuration
The SNMP is a Protocol that governs the transfer of information between management and agent.
The switch supports SNMP V1.
User can define management stations as trap managers and to enter SNMP community strings.
User also can define a name, location, and contact person for the switch. Fill in the system options
data, and then click Apply to update the changes.
SNMP Management interface
40
Download from Www.Somanuals.com. All Manuals Search And Download.
System Options
•
•
•
Name: Enter a name for the switch
Location: Enter the switch physical location
Contact: Enter the name of contact person or organization
Community strings
Serve as a password.
•
•
Strings: Key in the name of string
RO: Read only. Enables requests accompanied by this string to display MIB-object
information
•
•
RW: Read write. Enables requests accompanied by this string to display MIB-object
information and to set MIB objects
Add
And then, click
Trap Manager
A trap manager is a management station that receives traps, the system alerts generated by the
switch. If no trap manager is defined, no traps will issue. Create a trap manager by entering the IP
address of the station and a community string.
•
•
IP Address: Key in the trap device IP
Community Strings: The trap device community strings
Add
And then, click
•
Configuration Backup
In Configuration Backup, user can restore the backup configuration into the industrial switch. Also,
user can backup the configuration to TFTP server.
TFTP Restore Configuration
User can restore flash ROM value from TFTP server, but user must put the backup image in TFTP
server, industrial switch will download the image back to the flash.
•
•
TFTP Server IP Address: Key in the TFTP server IP
Restore File Name: Key in the restore file image name
Apply
And then, click
•
41
Download from Www.Somanuals.com. All Manuals Search And Download.
TFTP Restore Configuration interface
TFTP Backup Configuration
User can save current flash ROM value from the industrial switch to the TFTP server, then go to the
TFTP restore configuration page to restore the image value back to the industrial switch.
•
•
TFTP Server IP Address: Key in the TFTP server IP
Backup File Name: Key in the file image name
Apply
And then, click
•
TFTP Backup Configuration interface
TFTP Update Firmware
It provides the functions to allow a user to update the switch firmware. Before updating, make sure
user have user TFTP server ready and the firmware image is on the TFTP server.
•
•
TFTP Server IP Address: Key in user TFTP server IP
Firmware File Name: Key in the name of firmware image
42
Download from Www.Somanuals.com. All Manuals Search And Download.
Apply
And then, click
•
TFTP Update Firmware interface
Factory Default
Reset Switch to default configuration. Except the IP address, subnet mask, default gateway,
username, and password will remain as user configured.
Default
Click
button to reset switch to default setting
•
Factory Default interface
System Reboot
Reboot the Switch in software reset
Reboot
Click
button to reboot the switch
•
System Reboot interface
43
Download from Www.Somanuals.com. All Manuals Search And Download.
Save Configuration
Save the industrial switch configuration to the flash memory. Power off the industrial switch without
the saving, all changed configuration will lost.
Save Flash
Click the
button the save the configuration
•
Save Configuration Interface
Rate Control
Set up every port’s bandwidth rate and packet limitation type
•
Limit Packet type: Select the packet type that wants to filter. The packet types have all
type packet, broadcast/multicast/unknown unicast packet, broadcast/multicast packet, and
broadcast
packet
only.
The
broadcast/multicast/unknown
unicast
packet,
broadcast/multicast packet, and broadcast packet only are only for ingress packet. The
egress rate only supports all type packets
•
Band Width: The port1 ~ port 8, supports port ingress and egress rate control. For
example, assume port 1 is 10Mbps, users can set it’s effective egress rate as 1Mbps,
ingress rate is 500Kbps. The switch performs the ingress rate by packet counter to meet
the specified rate
•
Ingress: Select the port effective ingress rate. The valid range options are 128kbps,
256Kbps, 512Kbps, 1MB, 2MB, 4MB, and 8MB. The default value is “disable”
•
Egress for all: Select the port effective egress rate. The valid range options are 128kbps,
256Kbps, 512Kbps, 1MB, 2MB, 4MB, and 8MB. The default value is “disable”
Apply
And then, click
button to apply the configuration
•
44
Download from Www.Somanuals.com. All Manuals Search And Download.
Rate Control Interface
[NOTE]
1. Remember to execute the “Save Configuration” action, otherwise the new configuration will lose
when switch power off.
2. Qos and Rate control cannot be existed at the same.
System Log
Set up system log events and view the system log events
System Log Configuration
Reload
Click
button to get newest system log event
•
•
Clear
To clear the log events, click
button
If log event list more that one page, drag down the list to switch to different page.
System Log Client Mode: user can select in Client Only, Server Only, or Both mode
System Log Server IP: Assign the system log server IP
•
•
•
Apply
And then, click
button to apply the configuration
•
45
Download from Www.Somanuals.com. All Manuals Search And Download.
System Log Configuration interface
Event Configuration
User can select the system log events. When selected events occur, the system will send out the log
information. Also, per port log events can be selected.
•
System event selection: 4 selections – Device cold start, Power status, SNMP Authentication
Failure, and X-Ring topology change. Mark the checkbox to select the event. When selected
events occur, the system will produce the logs
‹
‹
‹
‹
Device cold start: When the device executes cold start action, the system will produce
a log message
Power status: When the device power status has changed, the system will produce a
log message
SNMP Authentication Failure: When the SNMP authentication fails, the system will
produce a log message
X-Ring topology change: When the X-Ring topology has changed, the system will
produce a log message.
•
Port event selection: Select the per port events. Per port have 3 selections – Link UP, Link
Down, and Link UP & Link Down. Disable means no event is selected.
‹
‹
‹
Link UP: The system will produce a log message when port connection is up only
Link Down: The system will produce a log message when port connection is down only
Link UP & Link Down: The system will produce a log message when port connection is
up and down
46
Download from Www.Somanuals.com. All Manuals Search And Download.
Apply
After selected, click
•
Event Configuration interface
47
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubles shooting
•
Verify that is using the right power cord/adapter (DC 12-48V), please don’t use the power
adapter with DC output bigger than 48V, or it will burn this converter down.
•
Select the proper UTP cable to construct user network. Please check that is using the right
cable. use unshielded twisted-pair (UTP) or shield twisted-pair ( STP ) cable for RJ-45
connections: 100ꢁ Category 3, 4 or 5 cable for 10Mbps connections or 100ꢁ Category 5 cable
for 100Mbps connections. Also be sure that the length of any twisted-pair connection does not
exceed 100 meters (328 feet).
•
•
•
Diagnosing LED Indicators: the Switch can be easily monitored through panel indicators to
assist in identifying problems, which describes common problems user may encounter and
where user can find possible solutions.
If the power indicator does turn on when the power cord is plugged in, user may have a problem
with power cord. Than check for loose power connections, power losses or surges at power
outlet. If user still cannot resolve the problem, contact user local dealer for assistance.
If the Industrial switch LED indicators are normal and the connected cables are correct but the
packets still cannot transmit. Please check user system’s Ethernet devices’ configuration or
status.
48
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Specification
IEEE 802.3 10Base-T Ethernet
IEEE 802.3u 100Base-TX and 100Base-FX Fast Ethernet
IEEE802.3x Flow Control and Back-pressure
IEEE802.1d spanning tree / IEEE802.1w rapid spanning tree
IEEE802.1p class of service
Standard
IEEE802.1Q VLAN Tag
Protocol
CSMA/CD
SNMP management
Management
Web interface management
One default button for system default setting
RFC 1213 MIBII
RFC 1493 Bridge MIB
RMON RFC 1757
RFC 2674 VLAN MIB
SNMP MIB
RFC 1643 Ethernet like MIB
RFC 1215 Trap MIB
Private MIB for switch information, X-Ring, port alarm, TFTP
firmware upgrade, reset, port mirror, IP security management,
IGMP management MIB.
Up to 3 Trap stations
Cold start
Port link Up
Port link down
SNMP Trap
Authentication Failure
Private Trap for power status
Port Alarm configuration
Fault alarm, X-Ring
Technology
Store and forward switching architecture
14,880 pps for 10Base-T Ethernet port
Transfer Rate
148,800 pps for 100Base-TX/FX Fast Ethernet port
Transfer packet size
64bytes to 1522 bytes (with VLAN tag)
49
Download from Www.Somanuals.com. All Manuals Search And Download.
4 types of packet filter rule with different packet combination:
¢
¢
¢
¢
All of packet
Packet filter
Broadcast/ multicast/ unknown unicast packet
Broadcast/ multicast packet
Broadcast packet only
MAC address
2K MAC address table
1Mbits
Memory Buffer
Per port: Link/Activity (Green), Full duplex/Collision (Yellow)
Per unit: Power (Green), Power 1 (Green), Power 2 (Green),
Fault (Yellow), Master (Green)
LED
10Base-T: 2-pair UTP/STP Cat. 3, 4, 5 cable
EIA/TIA-568 100-ohm (100m)
Network Cable
100Base-TX: 2-pair UTP/STP Cat. 5 cable
EIA/TIA-568 100-ohm (100m)
¢
¢
¢
¢
ST (Multi-mode): 50/125um or 62.5/125um
ST (Single mode): 9/125um
Optical cable
Back-plane
Available distance: 2KM (Multi-mode) / 30KM (single-mode)
Wavelength: 1310nm (multi-mode/ single mode)
1.6Gbps
Packet throughput
ability
1.19Mpps @64bytes
12 ~48 VDC
Power Supply
Redundant power with polarity reverse protects function and
connective removable terminal block for master and slave power.
Power consumption
7.68 Watts
2 ports for X-Ring to provide redundant backup feature and the
recovery time below 300ms and start by Web interface
management. The ring port can be defined by Web interface.
X-Ring
VLAN
Port based VLAN
IEEE802.1Q Tag VLAN.
Both of port based and Tag based VLAN group up to 64 VLANs.
IEEE802.1p class of service
Class of service
Quality of service
Per port provides 4 priority queues.
The quality of service determined by port, Tag and Ipv4 Type of
service.
50
Download from Www.Somanuals.com. All Manuals Search And Download.
IEEE802.1d spanning tree
Spanning tree
IGMP
IEEE802.1w rapid spanning tree.
IGMP v1 and Query mode
Up to 256 groups.
SMTP
SNTP
Support SNTP to synchronize system clock in Internet
Support SMTP Server and 4 e-mail accounts for receiving
event alert
Management IP security
Port mirror
IP address security to prevents unauthorized intruder
TX packet only
Both of TX and RX packet
TFTP firmware update
Firmware update
Alarm
TFTP backup and restore
One relay output for port breakdown and power fail
Dipswitch to mask link down port
Alarm Relay current carry ability: 1A @ DC24V
¢
¢
Ingress packets filter and egress packet limit.
The egress rate control supports all of packet type and
the limit rates are 128kbps, 256Kbps, 512Kbps, 1MB,
2MB, 4MB, and 8MB.
¢
¢
Ingress filter packet type combination rule for
Broadcast/Multicast/Unknown Unicast packet,
Broadcast/Multicast packet, Broadcast packet only and
all of packet.
Bandwidth control
The ingress packet filter rate can be set follow
as:1Mbps 2Mbps 4Mbps 8Mbps 16Mbps
32Mbps 64Mbps.
DHCP client
Install
DHCP client function to obtain IP address from DHCP serve
DIN rail kit and wall mount ear for wall mount or DIN-type
cabinet install
Standard Operating Temp. Model:
-10C to 60C (14F to 140F)
Operation Temp.
Wide Operating Temp. Model:
-40C to +75C (-40F to 167F)
Operation Humidity
Storage Temperature
5% to 95% (Non-condensing)
-40C to +85C
51
Download from Www.Somanuals.com. All Manuals Search And Download.
Case Dimension
IP-30, 54 mm (W) x 135 mm (H) x 105mm (D)
FCC Class A, CE EN61000-4-2 (ESD), CE EN61000-4-3 (RS),
CE EN-61000-4-4 (EFT),
EMI
CE EN61000-4-5 (Surge), CE EN61000-4-6 (CS), CE
EN61000-4-8, CE EN61000-4-11,
CE EN61000-4-12, CE EN61000-6-2, CE EN61000-6-4
Safety
UL, cUL, CE/EN60950-1
IEC60068-2-32 (Free fall)
IEC60068-2-27 (Shock)
IEC60068-2-6 (Vibration)
Stability testing
52
Download from Www.Somanuals.com. All Manuals Search And Download.
|
Technics Stereo Receiver SA GX130D User Manual
Toshiba Laptop Z930 S9311 User Manual
Toshiba Printer B 670 QQ User Manual
Toshiba Webcam R30 A User Manual
Tripp Lite Mouse IN3010KB User Manual
Tripp Lite Network Cables N201 010 BK User Manual
Varimixer Mixer W150N User Manual
Vector Marine Battery VEC024 User Manual
Vivitar Binoculars VIV CS 850 User Manual
Vornado Humidifier Ultrasonic Humidifiers User Manual