Tracer Controllers
Tracer MP580/581
Programmable Controllers
August 2006
CNT-PRC002-EN
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Product models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Inputs and outputs . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Product models and accessories . . . . . . . 4
Tracer MP580/581 models . . . . . . . . . . . . . . . . . . . . 4
Operator display models . . . . . . . . . . . . . . . . . . . . . 4
Expansion module . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Graphical programming . . . . . . . . . . . . . . . . . . . . . . 6
Operator display . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Engineered smoke control. . . . . . . . . . . . . . . . . . . . . 6
Interoperability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Network architecture . . . . . . . . . . . . . . . . 8
Wiring diagrams . . . . . . . . . . . . . . . . . . . . 9
Enclosure interior . . . . . . . . . . . . . . . . . . 11
Dimensions . . . . . . . . . . . . . . . . . . . . . . . 12
Specifications . . . . . . . . . . . . . . . . . . . . . 14
Tracer MP580/581 . . . . . . . . . . . . . . . . . . . . . . . . . . 14
MP581 NEMA-1 enclosure . . . . . . . . . . . . . . . . . . . 14
Frame-mounted MP581 . . . . . . . . . . . . . . . . . . . . . 14
Factory-installed MP580 . . . . . . . . . . . . . . . . . . . . . 14
Operator display . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
EX2 expansion module . . . . . . . . . . . . . . . . . . . . . . 15
CNT-PRC002-EN
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Product models and
accessories
Tracer MP580/581 models
Operator display models
Expansion module
Several models of Tracer MP580/581
controllers are available. Tracer MP581
Operator-display touch screens are
available as options for all Tracer MP580/
581 controllers. The operator-display
models are illustrated in Figure 2 on
You can use up to four EX2 expansion
modules to add extra points to a Tracer
MP580/581 controller. The expansion
modules communicate with the
controller on an IEEE-485 I/O bus up to
1000 ft (300 m) from the controller. The
EX2 expansion module is available in
two models:
Tracer MP580 on Trane air handlers
The Tracer MP580 controller is available
packaged with the following air handlers:
Door-mounted operator display
The door-mounted operator display
works with any Tracer MP581 or Tracer
AH541 controller. A retrofit kit is
available to add an operator display to an
existing Tracer MP581. The retrofit kit
includes a complete enclosure door with
an operator display mounted in it. The
door-mounted operator display is not
available for factory-mounted Tracer
MP580 controllers.
• M-Series Climate Changer air handlers
• T-Series Climate Changer air handlers
• AireSystems custom air handlers
• EX2 module in a metal enclosure
• EX2 module with a plastic cover
The controller is factory wired to all
sensors, actuators, valves, starters, and
other items shipped with the air handler.
Factory testing of connected points
helps minimize field commissioning
time and expense.
The EX2 models are illustrated in
Tracer MP580/581 controllers and the
expansion modules. Refer to
“Specifications” on page 14 for details
about each type of point.
Stand-alone operator display
The stand-alone operator display is
designed for permanent local
connection to a Tracer MP580/581 or
AH540/541 controller. The stand-alone
operator display includes a 7-day time
clock to provide scheduling for the
associated controller. The 10-foot
(3 meter) connector cable can be
extended up to 150 feet (46 meters).
Frame-mounted Tracer MP581
The frame-mounted Tracer MP581
consists of a circuit board and a
termination board mounted in a two-
piece modular-frame assembly. This
modular design allows the circuit board
to be stored separately while installation
and wiring are completed. The frame-
mounted model can be installed in new
equipment or existing enclosures.
Table 1. Total points available
Tracer
MP580/
581
Each
EX2
(up to 4)
Type of
point
Total
points
Universal
inputs
12
6
6
4
4
0
36
22
22
1
Portable operator display
Tracer MP581 with NEMA-1 enclosure
The Tracer MP581 with enclosure
consists of the frame assembly
mounted in an enclosure compliant with
National Electrical Manufacturers
Association (NEMA) type-1 standards. A
line-to-low voltage transformer is
included. The enclosure has a hinged
door and plenty of room for input and
output wiring. The assembly is UL-listed.
Binary
The portable operator display is
designed for temporary connection to a
Tracer MP580/581 or AH540/541
controller. The operator-display touch
screen is mounted in a resin enclosure,
which is placed in a padded, protective
carrying case. A 10-foot (3 meter)
connector cable is included.
outputs
Analog
outputs
6
Static pres-
sure input
1
Figure 1. Tracer MP581 models
Tracer MP581 with
optional operator display
Tracer MP581 without
operator display
Frame-mounted
Tracer MP581
4
CNT-PRC002-EN
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 2. Operator display models
Door-mounted operator display
for Tracer MP581 controllers
Portable operator display
Stand-alone
operator display
Figure 3. EX2 expansion modules
EX2 in metal enclosure
EX2 with plastic cover
Note: Expansion modules factory-installed with
Tracer MP580s consist of the circuit board only. The
modules shown here are available for field installation.
CNT-PRC002-EN
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Features
Figure 2 on page 5 illustrates the
operator-display models available for
Tracer MP580/581 controllers.
Graphical programming
Interoperability
The Tracer graphical programming (TGP)
editor, shown in Figure 5 on page 7,
eliminates the need for line-by-line
programming. The TGP editor is a
software component of the Trane Rover
service tool. TGP has the following
advantages:
Tracer MP580/581 controllers
communicate by means of the LonTalk
protocol. The controllers can be
Figure 4 shows a typical operator display
screen.
configured to conform to the LonMark®
Space Comfort Controller (SCC) profile
or the Discharge Air Controller (DAC)
profile. You can integrate Tracer MP580/
581 controllers with any control system
that supports these LonTalk protocols
and FTT10-A communications.
Figure 4. Typical status screen
• Easy to learn—programming is as
easy as assembling logic blocks with a
computer mouse, much like creating a
flow chart.
• Powerful—the TGP editor has built-in
PID functions and more than 50 logic
blocks for building programs.
• Self documenting—programs can be
printed and used as pictorial represen-
tations of sequences of operation (see
Security
You can use up to eight security
passwords to limit access to a Tracer
MP580/581 controller.
Use the security passwords to prevent
unauthorized access to:
• TGP programs stored in the controller
• Programs are stored in the controller
along with their graphical representa-
tion, and can be uploaded, viewed,
and re-used.
• Offline programming—configuration
and TGP programming can be done
without connecting to a Tracer
MP580/581 controller.
• Program simulation—programmers
can simulate TGP programs offline.
The programmer can verify, test, and
troubleshoot controller operation at a
remote location, simplifying setup,
maintenance, and service.
• Operator display functions, such as
setpoints and schedules
• Configuration downloads from a
LonTalk service tool
Engineered smoke control
Tracer MP580/581 controllers and EX2
expansion modules can be used to
control an engineered smoke control
system. When used with a fire alarm
control panel (provided by other
suppliers), the smoke-control system
can help protect occupants by
controlling the flow of smoke during a
fire.
For each of the security passwords, you
can choose what can and cannot be
accessed, including specific screens on
the operator display. The controller ships
with security disabled.
In addition to smoke control, with a
firefighter’s control panel, a firefighter
can see the status of smoke control and
implement overrides as required. The
Tracer MP580/581 and EX2 expansion
module are UL-864-UUKL-listed for this
application. For details, see the
Engineered Smoke Control System for
Tracer Summit applications guide, BAS-
APG001-EN.
Operator display
The optional operator-display touch
screen is an intuitive operator interface
for monitoring and changing building
control functions. With the operator
display, you can:
• Monitor space temperature, relative
humidity, and other variables
• Change setpoints and scheduled
occupancy times
• Identify and troubleshoot problems
• View and reset controller alarms
• Manually override outputs
The operator display includes a 7-day
time clock that gives Tracer MP580/581
controllers the ability to manage time-of-
day scheduling, with two on/off times
per day and up to 20 exception
schedules per year.
6
CNT-PRC002-EN
Download from Www.Somanuals.com. All Manuals Search And Download.
Network architecture
Tracer MP580/581 controllers can
operate as stand-alone controllers, on a
peer-to-peer network, or as part of a
Tracer Summit building automation
With an operator display, you can
monitor information and make control
changes on a peer-to-peer network.
Figure 7. Tracer MP581 controller as part of a building automation system with Trane LonTalk controllers
Tracer Summit
PC Workstation
Tracer AH541
Building
controlunit
(BCU)
Tracer ZN511
Tracer ZN521
Comm5 (LonTalk)
communications link
Tracer MP581
Tracer MP501
Tracer MP503
Rover service tool
I/O bus for up to four expansion modules
EX2 module with
metal enclosure
EX2 module
with plastic cover
8
CNT-PRC002-EN
Download from Www.Somanuals.com. All Manuals Search And Download.
Wiring diagrams
Figure 8 shows typical input and output
connections to the Tracer MP581
termination board. The Tracer MP581
termination board uses screw terminals.
The Tracer MP580 termination board
uses 0.25-inch quick-connect terminals.
For wiring within a smoke control
system, see Applications Guide,
Engineered Smoke Control System for
Tracer Summit, BAS-APG001-EN.
Figure 9 on page 10 shows typical input
and output connections to the EX2
expansion module.
Figure 8. Wiring diagram for the Tracer MP580/581
Powered output
<1000 ft
(300 m)
0–10 Vdc output
Load > 500 Ω
<1000 ft
(300 m)
<300 ft
(100 m)
Temperature sensor
0–20 mA sensor
<1000 ft
(300 m)
I/O bus to EX2
expansion modules up
to 1000 ft (300 m)
CNT-PRC002-EN
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 9. Wiring diagram for the EX2 expansion module
3-wire, 0–20 mA
sensor*
<1000 ft
(300 m)
24 Vac
transformer
2-wire, 0–20 mA
sensor
Powered
output
<1000 ft
(300 m)
<1000 ft
(300 m)
Temperature sensor
<300 ft
(100 m)
<300 ft
(100 m)
AC powered
actuator
I/O bus to Tracer MP580 and
EX2 expansion modules
up to 1000 ft (300 m)
*Note: Or a 3-wire 0–10 Vdc
sensor with a distance
limitation of 300 ft (100 m).
10
CNT-PRC002-EN
Download from Www.Somanuals.com. All Manuals Search And Download.
Enclosure interior
Figure 10 shows the interior of the
Tracer MP581 NEMA-1 enclosure.
Significant space is available for wiring
inputs and outputs. Wires should be
routed after the optional pressure
sensor is installed.
Tracer MP580 enclosure configurations
are customized in the factory to meet
customer requirements.
For interior details of a Tracer MP581
used in a smoke control system, see
Applications Guide, Engineered Smoke
Control System for Tracer Summit, BAS-
APG001-EN.
Figure 10. Tracer MP581 enclosure interior
Line-to-low voltage
power transformer
Main circuit board
Space for input and
output wire-routing
Mounting location
for optional static
pressure sensor
Termination board
CNT-PRC002-EN
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensions
Tracer MP581 NEMA-1 enclosure.
Figure 12 shows the dimensions of the
frame-mounted Tracer MP581 controller.
The dimensions of the operator display
models are listed in “Specifications” on
Figure 11. Tracer MP581 enclosure dimensions
Figure 12. Frame-mounted Tracer MP581 dimensions
12
CNT-PRC002-EN
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 13. EX2 plastic-cover module dimensions
5.625 in.
(143 mm)
6.313 in.
(160 mm)
6.875 in.
(175 mm)
5.375 in. (137 mm)
2 in. (51 mm)
Figure 14. EX2 metal-enclosure module dimensions
1.875 in.
(48 mm)
6.5 in.
(165 mm)
0.28 in.
(7 mm)
9 in.
(25mm)
9 in.
(229 mm)
7 in.
(178 mm)
10.37 in.
(263 mm)
with cover
1 in.
(25 mm)
10.25 in.
(260 mm)
without cover
2.25 in.
(58 mm)
CNT-PRC002-EN
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
Agency listings/compliance
CE—Immunity (directive 89/336/EEC)
EN 50090-2-2:1996
Tracer MP580/581
Frame-mounted
Tracer MP581
The specifications in this section apply
to all Tracer MP580/581 models.
Specifications not repeated here are the
same as for the NEMA-1 enclosure.
CE—Emissions (directive 89/336/EEC)
EN 50090-2-2:1996
EN 61000-3-2:1995
EN 61000-3-3:1995
Inputs and outputs
Twelve universal inputs
Power requirements
Nominal rating
24 Vac; 50/60 Hz; 1 phase
Dry contact binary (including pulse
accumulation), 0–20 mA, 0–10 Vdc,
linear resistance, or thermistor. The
first four inputs can be used directly
with resistance temperature
detectors (RTDs).
UL and C-UL listed
Energy management system
Voltage utilization range
24 Vac nominal: 19–30 Vac
UL 916
Operating environment
From –40°F to 158°F (–40°C to 70°C)
Humidity: 10–90% non-condensing
FCC approved: Part 15, Class A
Six binary outputs
UL-864-UUKL
Engineered smoke control
Tracer MP580: 3 VA per ordered
binary output isolation relay
Tracer MP581: 12 VA at 24 Vac
powered relay contacts
Dimensions
10.25 in. × 8 in. × 3.5 in.
(260 mm × 203 mm × 89 mm)
Tracer MP581 with
NEMA-1 enclosure
Power requirements
Nominal rating
120/230 Vac; 50/60 Hz; 1 phase
Six analog outputs
0–10 Vdc or 0–20 mA
Minimum clearances
0.5 in. (1.3 cm) top, right, and front
6 in. (15 cm) left (for I/O wiring)
3 in. (8 cm) bottom (for comm wiring)
Static pressure input
Specialized input for a Trane
differential pressure sensor
(5 Vdc, 0–5 in. wc)
Voltage utilization range
120 Vac nominal: 98–132 Vac
230 Vac nominal: 196–264 Vac
Weight
2 lb (1 kg)
Analog-to-digital conversion
Resolution: 12 bits
Mounting
Requires #8 (4 mm) screws
Operating environment
From 32°F to 122°F (0°C to 50°C)
Humidity: 10–90% non-condensing
Digital-to-digital conversion
Resolution: 12 bits
Factory-installed
Tracer MP580
Specifications not repeated here are the
same as for the NEMA-1 enclosure.
Storage environment
Temperature
Without display: From –58°F to 203°F
(–50°C to 95°C)
Microprocessor
Motorola MC68332 20 MHz
Memory
With display: From –13°F to 149°F
(–25°C to 65°C)
RAM: 512 K
ROM: 2 MB Flash
EEPROM: 256 K
Enclosure
On M-Series air handlers, the Tracer
MP580 controller is mounted in a
galvanized steel enclosure to minimize
costs, facilitate factory mounting, and
match unit construction. On T-Series air
handlers, the Tracer MP580 controller is
mounted in a control panel inside the
unit.
Humidity: 10–90% non-condensing
Time clock
Included with operator display; crystal
controlled, super-capacitor backed
Dimensions
16.5 in. × 14.75 in. × 5.5 in.
(418 mm × 373 mm × 140 mm)
Battery
Minimum clearances
12 in. (30 cm) top, bottom, and right
24 in. (60 cm) left
Not required—backed by super capacitor
for 7 days under normal operating
conditions; all other programs backed by
non-volatile memory
Operator display
36 in. (90 cm) front
On M-Series air handlers, the operator
display can be mounted at the factory or
shipped loose for field installation.
Operator displays are shipped loose for
T-Series air handlers. Door-mounted
operator displays are not available for the
Tracer MP580.
Weight
15 lb (7 kg)
Mounting
Wall-mounted with #10 (5 mm) screws
14
CNT-PRC002-EN
Download from Www.Somanuals.com. All Manuals Search And Download.
Operator display
EX2 expansion module
Touch screen
Inputs and outputs
Video graphics adapter (VGA) backlit
liquid crystal display (LCD) with touch
screen; 4.5 in. × 3.4 in. (115 mm ×
86 mm) viewable area; resolution of
320 × 240 pixels
Six universal inputs; four binary outputs;
four analog outputs
Mounting distance
Up to 1000 ft (300 m) from controller
Power requirements
Nominal rating
24 Vac; 50/60 Hz; 1 phase
Operating environment
From 32°F to 122°F (0°C to 50°C)
Humidity 10–90% non-condensing
Voltage utilization range
24 Vac nominal: 19–30 Vac
Portable and stand-alone enclosure
dimensions
10.25 in. × 8.75 in. × 2.25 in.
(260 mm × 222 mm × 58 mm)
Operating environment
From –40°F to 158°F (–40°C to 70°C)
Humidity 5–95% non-condensing
Mounting distance for stand-alone
operator display
10 ft (3 m) with attached cable;
extendable to 150 ft (46 m) as described
in the installation sheet for the stand-
alone operator display (3270 3338).
Storage environment
From –40°F to 185°F (–40°C to 85°C)
Humidity 5–95% non-condensing
Dimensions
Metal-enclosure module:
10.25 in. × 9 in. × 2.25 in.
(260 mm × 229 mm × 58 mm)
Plastic-cover module:
6.875 in. × 5.375 in. × 2 in.
(175 mm × 137 mm × 51 mm)
Minimum clearances
Metal-enclosure module:
1 in. (25 mm) top, bottom
2 in. (51 mm) left, right
24 in. (610 mm) front
Plastic-cover module:
1 in. (25 mm) top, bottom
4 in. (102 mm) left, right, front
Weight
Metal-enclosure module: 8 lb (4 kg)
Plastic-cover module: 2 lb (1 kg)
CNT-PRC002-EN
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Literature Order Number
File Number
CNT-PRC002-EN
PL-ES-CNT-PRC002-0806
CNT-PRC002-EN March 2003
Inland
Supersedes
Trane
A business of American Standard Companies
Stocking Location