When using Windows NT Server 4.0
(1) Be sure to connect a mouse to the server.
If you use the server without a mouse, the keyboard
may become inoperative.
(2) Installing Windows NT Server 4.0 to the server
whose memory capacity exceeds 1,7MB
When the memory capacity exceeds 1,7MB,
Windows NT Server 4.0 cannot be installed because
of the limitations of Windows NT Server 4.0. In this
case, use the following procedure to install
Windows NT Server 4.0.
1/15
S00047-EN EH02 Rev. E
Download from Www.Somanuals.com. All Manuals Search And Download.
If the "530LTX" label is attached on the
connector panel:
Connection Type: Auto-Negotiation
Network Address: (Blank)
If the no label is attached on the connector panel:
Connection Type: Auto-Sense
Network Address: (Blank)
When using Windows 2000 Server
(1)Be sure to connect a mouse to the server.
If you use the server without a mouse, the keyboard
may become inoperative.
(2)Installing Windows 2000 Server to the server
with an MO device.
Using an MO device with this server may prevent the
correct installation of Windows 2000 Server. In this
case, remove the MO device before installing
Windows 2000 Server. As a precaution, replace the
server’s panels before switching it on. For installing
and removing the MO device, refer to MAGNIA
User’s Guide (on the Documentation CD ROM),
Chapter 2.
3/15
S00047-EN EH02 Rev. E
Download from Www.Somanuals.com. All Manuals Search And Download.
When using NetWare 5.1
Follow the installation procedure described in the
instruction manual to ensure that the installation is
done properly.
About expansion of optional RAID controller D
When you use Server Setup Tool to setup the server
with RAID controller D (MR466), the [Detailed Setup]
option may not setup right. To set RAID configuration
details with Server Setup Tool, use the following
procedure.
(1) When the message [Press <Ctrl><M> to Run
MegaRAID Configuration Utility] is displayed during
the server boot, press [Ctrl]+[M]. After MegaRAID
Configuration Utility is started, set RAID
configuration in detail, and select [Logical
Drive]-[Advanced
Menu]-[Write
Policy],
set
[WRTHRU] to the array that is installed on the OS.
For operation procedures about MegaRAID
Configuration Utility, refer to MegaRAID User's
manual.
(2) After setting RAID configuration details, insert the
Server Setup Tool CD-ROM and the Startup Disk
floppy disk in the CD-ROM drive and the floppy disk
drive respectively, then restart the system to start
the Server Setup Tool.
4/15
S00047-EN EH02 Rev. E
Download from Www.Somanuals.com. All Manuals Search And Download.
(3) Open the Server Setup Tool [Main Menu], and click
the [Setup] button to start setup wizard. When the
[RAID Configuration screen] dialog box is displayed,
check [Skip RAID Setup] check box, and continue
the setup wizard. For setup wizard, refer to Server
Setup Tool User's guide.
(4) After setup, regarding the array that is installed on
the OS, we recommend setting the logical drive's
[Write Policy] setting to [WRBACK] using MegaRAID
Configuration Utility or Power Console.
Tape Attached to the CPU Heat Sink
Protective tape is attached to the heat sink to prevent it
separating from the CPU during transit. This protective
tape need not be removed under normal conditions.
However, you must remove it when you remove the
CPU or heat sink.
CAUTION
Do not remove the tape immediately after turning off
power, since the temperature of the CPU and
surrounding parts are still high immediately after the
power is turned off. When you reinstall the CPU or
heat sink, there is no need to reattach the tape to the
heat sink.
5/15
S00047-EN EH02 Rev. E
Download from Www.Somanuals.com. All Manuals Search And Download.
When attaching or removing the SCSI HDD/
SCSI devices
When attaching the side covers, take care to prevent
the cables from being nipped between the side cover
and the server.
About expansion of optional SCSI Host Adapter
SCI1105W/J, SCI1107A/W/J and SCI3900U
An OS may not start depending on the connection.
Perform the following setting for the SCSI host adapter
not connected to an HDD starting OS.
(1)In the BIOS screen of SCSI Host adapter during
start of system, press[Ctrl] + [A] to enter the BIOS
setting menu.
(2)Select [Configure/View Host Adapter Setting] from
the Options menu.
(3)Select [Advanced Configuration Options] from the
Additional Options menu.
(4)Change the setting of [Host Adapter BIOS] of
[Options Listed Below Have NO EFFECT if the BIOS
is Disabled] from [Enabled] to [Disabled: scan bus].
About an accuracy of the Real-time-clock (RTC)
The RTC has a certain error, and the error is increased
cumulatively if it is remained. To avoid the harmful
influence for the operation, adjust the clock
periodically.
A clock adjustment is enabled with each OS and BIOS setup utility.
For details of adjustment, refer to each manual.
6/15
S00047-EN EH02 Rev. E
Download from Www.Somanuals.com. All Manuals Search And Download.
Components List
Unpack and check components.
If anything is missing, contact your dealer immediately.
Save the packaging materials for possible future use.
Components
Quantity
1
MAGNIA 510D
Media
Server Setup Tool (SST) CD-ROM
Server Setup Tool (SST) Startup Disk
LANDesk Server Manager (LDSM)
(CD-ROM)
(FD:1)
1
1
(CD-ROM)
1
MAGNIA 510D User’s Guide (Documentation CD ROM)
1
Documentation
MAGNIA 510D Read-Me-First Addendum(This document)
1
Server Setup Tool (SST) User's Guide (Documentation CD ROM)
1
Software License Agreement
Warranty Booklet
Keyboard
1
1
1
Other
Mouse
1
Power Cable
1
Screw and rails
1set
7/15
S00047-EN EH02 Rev. E
Download from Www.Somanuals.com. All Manuals Search And Download.
733MHz P3 256K CPU Kit-LA / 866MHz P3 256K CPU Kit-LA / 1GHz P3 256K CPU Kit-L
Read-Me-First
Please read the following sheet before you start using CPU Kit-LA on MAGNIA 510D.
1. About the system BIOS of MAGNIA510D
Some CPU Kit-LA with maker S-Spec code cannot be used in MAGNIA 510D,
which BIOS revision was before F6TJ.
In this case, you must update your BIOS to latest revision.
(A) Check your CPU Kit-LA’s maker S-Spec code by mark of CPU.
R
Pentium !!! xxxxx
XXXXXXXXXXXXXXX
XXXXXXXX-XXXX SSSSS
S-Spec code
CPU Module
UPG3141W
UPG3142W UPG3143W
(733MHz)
(866MHz)
(1BGHz)
Stepping
S-Spec
B0
C0 D0
C0 D0
C0 D0
SL3X SL4 SL4Z SL4 SL4Z SL4 SL52
Y
CG
Yes
Yes
Yes
L
CB
Yes
Yes
Yes
J
C8
R
BIOS F4TJ
Yes
Yes
Yes
No
No
Yes
No
No
Yes
Yes
Yes
Yes
No
No
Yes
BIOS F5TJ
BIOS F6TJ or
later
“No” : It is necessary to update the BIOS to F6TJ or to a later version.
“Yes” : It is not necessary to update the BIOS.
8/15
S00047-EN EH02 Rev. E
Download from Www.Somanuals.com. All Manuals Search And Download.
(B) Check System BIOS revision by POST messages.
American Release:xx/xx/xxxx
Megatrends AMIBIOS (C) 1999 American Megatrends
Inc.,
6VXD7 XX XX
Check System Health ok ,
BIOS revision
CPU ID:XXXX Patch ID:XXXX
Pentium III XX-XXXMHz
Check NVRAM…
XXXXXKB OK
Hit DEL if you want to run SETUP
Wait…
Press F1 to enter Dual BIOS Utility. Press ESC to quit
( C ) American Megatrends Inc.,
XX-XXXX-XXXXXX-XXXXXXXX-XXXXXX-XXXXXXXX-XX-XXXXXX-X
(C) How to get the latest BIOS
For the latest information and updates, please visit:
(D) Install the CPU Kit-LA
For detail, refer to your MAGNIA 510D User’s Guide (on the Documentation CD).
2. In case of using Windows2000
If the CPUs in your multiprocessor system are not at the same Stepping levels,
Windows 2000 writes the following message to the Event Log. The MAGNIA series
with mixed Stepping levels can be used together without any problem, so you can
disregard the message.
Event ID
Message
: 41
:
The CPUs in this multiprocessor system are not all the same revision level.
To use all processors the operating system restricts itself to the features of the least
capable Processor in the system.
Should occur with this system, contact the manufacturer to see if this mix of
processors is supported.
9/15
S00047-EN EH02 Rev. E
Download from Www.Somanuals.com. All Manuals Search And Download.
[To view CPU Stepping levels on your computer]
1. Click “Start”, point to “Programs”, point to “Administrative” Tools, and then
click “Computer Management”.
2. Double-click the “System Information” folder, and then click the “System
Summary” folder.
Check the Processor line to view the CPU Stepping levels.
B0 Stepping : x86 Family 6 Model 8 Stepping 3
C0 Stepping : x86 Family 6 Model 8 Stepping 6
D0 Stepping : x86 Family 6 Model 8 Stepping 10
3. About the combination of D0-Stepping CPU and “LDSM6.1 with TOSHIBA
Extension” in MAGNIA510D
When combining D0-Stepping CPU and "LDSM6.1 with TOSHIBA Extension" in
MAGNIA510D, it is necessary to install "LDSM6.1 with TOSHIBA Extension V6.2.1”
or later.
10/15
S00047-EN EH02 Rev. E
Download from Www.Somanuals.com. All Manuals Search And Download.
Contact Directory
The List of contacts may change and not be necessarily complete because of the
continuous launch of server. For updates of the contact information please refer to:
Please also keep in mind that the warranty is only applicable to the country of first
purchase.
E.g if a server is sold by a German authorised dealer, the warranty is only valid in Germany.
If you need service in another places than in the country of purchase please refer to your
dealer for offers.
Austria
Toshiba Europe GmbH
Handelskai 388
1020 Wien
Tel: 0800-220150
Fax: +43-1-72031002
Belgium
Toshiba Information Systems (Belgium) S.A.N.V.
Excelsiorlaan 40
B - 1930 Zaventem
Tel: +32-2-7158700
Fax: +32-2-7253030
Czech Republic
CHG SERVICE, s.r.o.
Vídenská 102
619 00 Brno
Tel: +420 5 4742 65-11 or -81
Fax: +420 5 4742 65-13 or -90
11/15
S00047-EN EH02 Rev. E
Download from Www.Somanuals.com. All Manuals Search And Download.
Denmark
Toshiba Digital Media
Naverland 27
DK-2600
Glostrup
Tel: +45-3823 7600
Fax: +45-3823 7601
Finland
Scribona TPC Oy / Toshiba Digital Media
Sinimäentie 8 A
PL 83 SF-02630
Espoo
Tel: +358-9 527 2555
Fax: +358-9 527 2500
France
Toshiba Systemes (France) S.A.
7, Rue Ampere; B.P. 131
F - 92804
Puteaux Cedex
Tel: +33-1-4728-2929
Fax: +33-1-4728-2247
Germany
Toshiba Europe GmbH
Leibnizstrasse 2
93055 Regensburg
Tel: 0800-8737837
Fax: +49-(0)941-7807-925
BBS: +49-(0)941-7807-999
ISDN1: +49-(0)781
12/15
S00047-EN EH02 Rev. E
Download from Www.Somanuals.com. All Manuals Search And Download.
Greece
IDEAL Electronics S.A.
190 Syngrou Ave.
176 71 Kalithea
Tel: +30 - 1 - 95.62.551-4
Fax: +30-1-95.79.094
Ireland
Toshiba Information Systems (U.K.) Limited (for Ireland)
Toshiba Court: Addlestone Road
KT15 2UL Weybridge, Surrey, UK
Tel: +44-(0)1932-828828
Fax: +44-(0)1932-822958
BBS: +44-(0)1932-825127
Italy
Tel etc: provided with purchase of server
Luxemburg
Toshiba Inf. Systems Benelux B.V. (for Luxemburg)
Rivium Boulevard 41
NL - 2909 LK
Capelle a/d IJssel
Tel: +31-10-2882-300
Fax: +31-10-2882-390
Malta
Tabone Computer Centre Limited
111 Old Railway Track
HMR-16 St Venera
Tel: +356-49 36 04
Fax: +356-49 36 03
13/15
S00047-EN EH02 Rev. E
Download from Www.Somanuals.com. All Manuals Search And Download.
Netherlands
Toshiba Inf. Systems Benelux
Rivium Boulevard 41
NL - 2909 LK Capelle a/d IJssel
Tel: +31-10-2882-300
Fax: +31-10-2882-390
Norway
Scribona Norway AS
Stålfjæra 20
P.O.Box 51/Kalbakken
N-0901 Oslo
Tel: +47-22-897000
Fax: +47-22-897389
Poland
AC Serwis Sp. z o. o.
ul. Partyzantów 71
43-316 Bielsko-Biala
Tel: +48-33-81 30-2 05
Fax: +48-33-81 30-2 09
Romania
SCOP COMPUTERS SRL
162 Barbu Vacarescu St
Sector 2
71424 Bucharest
Tel: +40-1-2 31-46 02
Fax: +40-1-2 31-46 06
14/15
S00047-EN EH02 Rev. E
Download from Www.Somanuals.com. All Manuals Search And Download.
Spain
Toshiba Inf. Systems (Espana) S.A.
Parque Empresarial San Fernando
Edificio Europa, 1a Planta, Escalera A
E - 28831 Madrid
Tel: +34-91-6606-700
Fax: +34-91-6606-760
Sweden
Scribona Sweden AB
P.O.Box 1374
Sundbybergsvägen 1
S-17127 Solna
Tel: +46-200-212100
Fax: +46-8-7344656
United Kingdom
Toshiba Information Systems (U.K.) Limited
Toshiba Court
Weybridge Business Park, Addlestone Road
KT15 2UL Weybridge, Surrey
Tel: +44-(0)1932-828828
Fax: +44-(0)1932-822958
BBS: +44-(0)1932-825127
15/15
S00047-EN EH02 Rev. E
Download from Www.Somanuals.com. All Manuals Search And Download.
|