MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE
(Addendum to GFC7000E Manual PN 04584)
MODEL GFC7000EU
CO2 ANALYZER
(Addendum to GFC7000E Manual PN 04584)
Teledyne Analytical Instruments
16830 Chestnut St.
City of Industry, Ca. 91748
TEL: 626-961-9221
FAX: 626-961-2538
TEL: 626-934-1500
E-MAIL: [email protected]
1
05134 Rev -
Download from Www.Somanuals.com. All Manuals Search And Download.
MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE
(Addendum to GFC7000E Manual PN 04584)
Humidity Range
Temp Coefficient
Voltage Coefficient
Dimensions
(HxWxD)
0-95% RH, Non-Condensing
< 0.05 % of reading per °C (5 ppb/°C minimum)(6)
< 0.05 % of reading per V
7" x 17" x 23.5" (178 mm x 432 mm x 597 mm)
Weight
50 lb (22.7 kg)
AC Power
100V 50/60 Hz (3.25A), 115 V 60 Hz (3.0A),
220 – 240 V 50/60 Hz (2.5A)
Installation Category (Over voltage Category) II
Pollution Degree 2
Environmental
Conditions
Analog Outputs
Analog Output
Ranges
Three (3) Outputs
100 mV, 1 V, 5 V, 10 V, 2-20 or 4-20 mA isolated
current loop.
All Ranges with 5% Under/Over Range
Analog Output
Resolution
1 part in 4096 of selected full-scale voltage
Status Outputs
Control Inputs
I/O
8 Status outputs from opto-isolators
6 Control Inputs, 2 defined, 4 spare
One (1) RS-232; One (1) RS-485/RS-232/Ethernet
Baud Rate : 300 - 115200
Certifications
CE: EN61010-1:90 + A1:92 + A2:95, EN61326 - Class
A
(1)
(2)
(3)
(4)
(5)
As defined by the USEPA
At constant temperature and voltage
Or 0.2 ppm, whichever is greater
Or 0.1 ppm, whichever is greater
Above 10 ppm range, otherwise 0.2 ppm for lower ranges
3.1.2. Pneumatic Connections
This section is similar to the one in the manual, with the following exception. The
extra port labeled “From Purge” is the exhaust port for the for the purge gas. The
gas needs to exhausted with a gas line not more than 10 meters long.
In addition, the GFC7000EU uses a different sample pressure sensor than the
GFC7000E. The GFc7000EU pressure sensor is rated for oxygen service. The part
number is listed in the appendix – spare parts.
6.13.1.3 Relay alarm outputs
3
05134 Rev -
Download from Www.Somanuals.com. All Manuals Search And Download.
MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE
(Addendum to GFC7000E Manual PN 04584)
There are 4 relay alarm outputs (AL1-AL4) on the rear panel. AL1 is for system
okay, AL2 is for concentration limit 1 exceeded and AL3 is for concentration limit 2
exceeded. The relay alarm output AL1 is enabled all the time, whereas the AL2 and
AL3 can be enabled/disabled by going into the diagnostics menu (with 929
password), then factory options, then turning conc. Alarm Relays ON or OFF. When
the concentration alarm relays are enabled, concentration alarms status is no longer
available through the “Status output” pins. So, either the alarm relays or the status bits
could be used to monitor the concentration alarms but not both at the same time. The
default factory setting is to enable the concentration alarm relays. The AL1 relay is
energized when the system is okay and de-energized when the system has a fault. The
AL2 and AL3 relays energize when the corresponding concentration limits are
exceeded.
11.1.1. Interpreting WARNING Messages
The most common and/or serious instrument failures will result in a warning message
being displayed on the front panel. The table below lists warning messages, along with
their meaning and recommended corrective action.
It should be noted that if more than two or three warning messages occur at the same
time, it is often an indication that some fundamental analyzer sub-system (power supply,
Relay Board, Motherboard) has failed rather than indication of the of the specific failures
referenced by the warnings. In this case, it is recommended that proper operation of
power supplies, the Relay Board, and the A/D Board be confirmed before addressing the
specific warning messages.
The analyzer will alert the user that a Warning Message is active by displaying the
keypad label MSG on the Front Panel. In this case the Front panel display will look
something like the following:
SAMPLE
RANGE=50.00 PPM
CO = 00.00
<TST TST> CAL
MSG
CLR SETUP
The analyzer will also alert the user via the Serial I/O COM port(s) and cause the FAULT
LED on the Front panel to blink.
To View or Clear the various warning messages press:
4
05134 Rev -
Download from Www.Somanuals.com. All Manuals Search And Download.
MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE
(Addendum to GFC7000E Manual PN 04584)
SAMPLE
WHEEL TEMP WARNING
CO = XX.XX
TEST
deactivates Warning
Messages until New warning(s)
are activated
TEST
CAL
MSG
CLR SETUP
MSG
activates Warning
Messages.
RANGE=50.0 PPM
SAMPLE
CO = XX.XX
<TST TST
> keys replaced with
MSG
< TST TST > CAL
CLR SETUP
TEST
key
WHEEL TEMP WARNING
< TST TST > CAL MSG
SAMPLE
CO = XX.XX
CLR
Press
to clear the
message currently being
Displayed.
CLR
SETUP
If more than one warning is
active the next message will
take its place
Once the last warning has been
cleared, the analyzer returns to
SURE
messages are
LEGITIMATE PROBLEMS.
Make
warning
NOT
due to
.
SAMPLE
Mode
Figure: Viewing and Clearing Warning Messages
NOTE: A failure of the analyzer’s CPU or Mother Board can result in any or ALL of the
following messages.
Table: Warning Messages
Warning
Message
Fault Condition
Possible Causes
. Bench Heater
BENCH TEMP
WARNING
The optical bench
temp is controlled at
48 ± 5 °C.
. Bench Temperature Sensor
. Relay controlling the Bench Heater
. Entire Relay Board
. I2C Bus
BOX TEMP
WARNING
Box Temp is < 5 °C
or > 48 °C.
Box Temperature typically runs ~7oC warmer than
ambient temperature.
. Poor/blocked ventilation to the analyzer.
. Stopped Exhaust-Fan
. Ambient Temperature outside of specified
range
. Measured concentration value is too high or
low.
. Concentration Slope value to high or too low
. Measured concentration value is too high.
. Concentration Offset value to high
CANNOT DYN
SPAN
Dynamic Span
operation failed
CANNOT DYN
ZERO
Dynamic Zero
operation failed
. Failed Disk on Chip
. User erased data
CONFIG
INITIALIZED
Configuration and
Calibration data
reset to original
Factory state.
. Failed Disk on Chip
. User cleared data
DATA
INITIALIZED
Data Storage in
iDAS was erased
5
05134 Rev -
Download from Www.Somanuals.com. All Manuals Search And Download.
MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE
(Addendum to GFC7000E Manual PN 04584)
Warning
Message
Fault Condition
Possible Causes
FRONT PANEL
WARN
The CPU is unable to
Communicate with
the Front Panel
WARNING only appears on Serial I/O COM Port(s)
Front Panel Display will be frozen, blank or will not
respond.
Display /Keyboard
. Failed Keyboard
. I2C Bus failure
. Loose Connector/Wiring
. Failed IR Photo-Detector
. Failed Sync/Demod Board
. IR Photo-Detector improperly attached to the
Sample Chamber
PHOTO TEMP
WARNING
PHT DRIVE is
>4750 mVDC or
<250 MVDC
. BENCH TEMP too high.
REAR BOARD
NOT DET
Mother Board not
detected on power
up.
WARNING only appears on Serial I/O COM Port(s)
Front Panel Display will be frozen, blank or will not
respond.
. Massive Failure of Mother Board
. I2C Bus failure
. Failed Relay Board
. Loose connectors/wiring
RELAY BOARD
WARN
The CPU cannot
communicate with
the Relay Board.
. Loss of purge flow
. Failed purge pressure sensor
. Purge pressure regulator not set properly
PURGE PRESS
WARN
Purge Pressure
outside of warning
limits specified by
PURGE_PRESS_SET
variable
SAMPLE PRES
WARN
Sample Pressure is
<15 in-Hg or
If Sample Pressure is < 15 in-HG:
. Blocked Particulate Filter
. Blocked Sample Inlet/Gas Line
> 35 in-Hg
Normally 29.92 in-
Hg at sea level
decreasing at 1 in-
Hg per 1000 ft of
altitude (with no
flow – pump
. Failed Pressure Sensor/circuitry
If Sample Pressure is > 35 in-HG:
. Blocked Vent line on pressurized
Sample/Zero/Span gas supply
. Bad Pressure Sensor/circuitry
. Failed Permapure dryer
disconnected).
. Ambient Temperature outside of specified
range
. Failed Bench Heater
SAMPLE TEMP
WARN
Sample temperature
is < 10oC or >
100oC.
. Failed Bench Temperature Sensor
. Relay controlling the Bench Heater
. Failed Relay Board
. I2C Bus
. GFC Wheel stopped
. Failed Sync/Demod Board
If Status LED’s on the Sync/Demod Board ARE
SOURCE
WARNING
Occurs when CO Ref
is <1250 mVDC or
>4950 mVDC.
flashing the cause is most likely a failed:
. IR Source
Either of these
conditions will result
in an invalid M/R
ratio.
. Relay Board
. I2C Bus
. IR Photo-Detector
. GFC Wheel stopped
. GFC Wheel rotation very slow/dragging
SYNC
WARNING
Phase Lock Loop
(PLL) has lost lock
6
05134 Rev -
Download from Www.Somanuals.com. All Manuals Search And Download.
MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE
(Addendum to GFC7000E Manual PN 04584)
Warning
Message
Fault Condition
Possible Causes
. Failed Sync/Demod Board
on wheel rotation.
If Status LED’s on the Sync/Demod Board ARE
flashing the cause is most likely an a problem with
the analyzer’s main power:
. Intermittent loss of the power supply too short
to cause a SYSTEM RESET warning;
. Frequency problem with the AC Mains.
The computer has
rebooted.
SYSTEM RESET
This message occurs at power on.
If it is confirmed that power has not been
interrupted:
. Failed +5 VDC power,
. Fatal Error caused software to restart
. Loose connector/wiring
. Blocked Cooling Vents below GFC Assembly
. Analyzer’s Top Cover removed
. Wheel Heater
WHEEL TEMP
WARNING
The filter wheel
temperature is
controlled at 68 ± 5
°C
. Wheel Temperature Sensor
. Relay controlling the Wheel Heater
. Entire Relay Board
. I2C Bus
APPENDIX B – GFC7000EU Spare Parts List
NOTE
Use of replacement parts other than those supplied by API may result in
non-compliance with European standard EN 61010-1.
Table B-1: GFC7000EU Individual Spare Parts List
Part
Description
Number
000941000
003291500
006110200
009550500
009600400
CD, Orifice, 13 mil
Assy, Thermistor, Bench Wheel, M300E
Assembly, Motor Wheel Heater, 50W 120V
Source Assembly (with Adapter)
M300E 47 mm Filter Expendables Kit - KNF Pump Model
7
05134 Rev -
Download from Www.Somanuals.com. All Manuals Search And Download.
MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE
(Addendum to GFC7000E Manual PN 04584)
#N05ATI
009690000
009690100
009820200
010790000
010800000
016290000
016910000
019340000
024710000
024720000
024750000
033520000
033560000
035950100
036110400
036310000
037250000
039750000
040010000
040030300
035280000
040690200
040880000
041350000
041710000
045840000
043940000
046730000
FL0000001
Filter, TFE, 47 mm 5 um, Qty 100
Filter, TFE, 47 mm 5 um, Qty 25
Assy, Motor, Synchronous, 115V/60HZ, "E"
Input Mirror
Output Mirror
Window, Sample Filter, 47 mm
Akit, Catalyst, CO/CO2 Converter (1 OZ)
Sample Thermistor M400 (S/N >099) or M401 (S/N>0573)
Tubing: 6', 1/8"CLR
Tubing: 6', 1/8" BLK
Tubing: 6', 1/4" TYGON
Objective Mirror, M300E+B17
Field Mirror, 32 Pass, M300E
Disk-On-Chip with Software
Sync Demodulator Board
4-20 mA Output PCA
Assembly, Heater, Optical Bench
Keyboard
ASSY, Fan Rear Panel, E Series
PCA, Press Sensors w/SW49
CO2 Scrubber Assembly
Mother Board, relay alarm outputs
Wheel Position Sensor Assembly
Relay Board
CPU
Operators Manual for M360E
Ethernet Interface PCA
Internal Multi-Drop PCA
Sintered Filter (002-024900)
HW0000090 Spring, Flow Control
HW0000036 TFE Thread Tape (48 FT)
HW0000101 Shockmount, Pump
SW0000034 Replacement, Optical Switch , M300E
OP0000009
Window, Sapphire
8
05134 Rev -
Download from Www.Somanuals.com. All Manuals Search And Download.
MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE
(Addendum to GFC7000E Manual PN 04584)
OR0000001
OR0000058
OR0000034
OR0000039
OR0000041
043590100
PU0000022
PS0000025
PS0000011
042680000
042690000
039060000
O-Ring, Flow Control
O-Ring, Sample Filter, 47 mm, 2-228V
O-Ring, Input/Output Mirror/Detector
O-Ring, Window
O-Ring, Field and Objective Mirror
Pump, 115V 50/60 Hz
Pump Rebuild Kit, KNF Model #N05ATI
Power Supply, +12V
Power Supply, +5/+- 15V
Solenoid, Stainless Steel, 3-Way, 12V
Solenoid, Stainless Steel, 2-Way, 12V
Assy, Pressure Transducer, M360U/GFC7000
Table B-2: GFC7000E Expendables List
Part
Description
Qty
Number
009600400
M300E Expandables Kit Includes:
This kit contains the following items
Akit, TFE Fltr. Elements, 47mm, 5um (25)
Sintered Filter (002-024900)
009690100
FL0000001
1
1
1
2
1
HW0000020 Spring, Flow Control
OR0000001
PU0000022
Note01-23
O-Ring, Flow Control
Pump Rebuild Kit, KNF Model #NO5ATI
Service Note, How to rebuild KNF pump
Table B-3: GFC70000E Spares Kit for 1 Unit
Part Number Description
Qty
040360100
M300E Spares Kit for 1 unit:
This kit contains the following items
Assy, Source, GFC7000E S/N >65
Assy,Fan Rear Panel, E series
009550500
040010000
RL0000015
1
1
1
Relay, DPDT, Gordos Preferred
9
05134 Rev -
Download from Www.Somanuals.com. All Manuals Search And Download.
|