TOA Electronics Stereo Amplifier A 706 User Manual

OPERATING INSTRUCTIONS  
700 SERIES AMPLIFIERS  
A-706, A-712, A-724  
TABLE OF CONTENTS  
1. IMPORTANT SAFETY INSTRUCTIONS ........................................................................................ 2  
2. SAFETY PRECAUTIONS ............................................................................................................... 2  
3. GENERAL DESCRIPTION ............................................................................................................. 4  
4. FEATURES ..................................................................................................................................... 4  
5. NOMENCLATURE AND FUNCTIONS  
Front ................................................................................................................................................ 4  
Rear ................................................................................................................................................ 5  
6. CONNECTIONS  
6.1. Speaker Connections ............................................................................................................... 6  
6.2. Remote Volume Control Connection ........................................................................................ 6  
6.3. Remote Power ON/OFF Control Connection ........................................................................... 7  
6.4. Mute Control Connection ......................................................................................................... 7  
6.5. External Equipment Connection to the PRE AMP OUT and PWR AMP IN Terminals ............ 7  
7. INSTALLATION .............................................................................................................................. 7  
8. RACK MOUNTING ......................................................................................................................... 8  
9. CONTROL SETTINGS ................................................................................................................... 8  
10. DIMENSIONAL DIAGRAM ............................................................................................................. 8  
11. BLOCK DIAGRAM ......................................................................................................................... 9  
12. SPECIFICATIONS ........................................................................................................................ 10  
Accessories ................................................................................................................................... 10  
Optional products .......................................................................................................................... 10  
Thank you for purchasing TOA's 700 Series Amplifiers.  
Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
surface. Doing so may result in the unit falling  
down, causing personal injury and/or property  
damage.  
cord itself. Operating the unit with a damaged  
power supply cord may cause a fire or electric  
shock.  
When the Unit is in Use  
• When moving the unit, be sure to remove its power  
supply cord from the wall outlet. Moving the unit  
with the power cord connected to the outlet may  
cause damage to the power cord, resulting in fire or  
electric shock. When removing the power cord, be  
sure to hold its plug to pull.  
• Should the following irregularity be found during  
use, immediately switch off the power, disconnect  
the power supply plug from the AC outlet and  
contact your nearest TOA dealer. Make no further  
attempt to operate the unit in this condition as this  
may cause fire or electric shock.  
· If you detect smoke or a strange smell coming  
from the unit.  
· If water or any metallic object gets into the unit  
· If the unit falls, or the unit case breaks  
· If the power supply cord is damaged (exposure of  
the core, disconnection, etc.)  
• Avoid installing the unit in humid or dusty locations,  
in locations exposed to the direct sunlight, near the  
heaters, or in locations generating sooty smoke or  
steam as doing otherwise may result in fire or  
electric shock.  
When the Unit is in Use  
· If it is malfunctioning (no tone sounds.)  
• Do not place heavy objects on the unit as this may  
cause it to fall or break which may result in  
personal injury and/or property damage. In  
addition, the object itself may fall off and cause  
injury and/or damage.  
• To prevent a fire or electric shock, never open nor  
remove the unit case as there are high voltage  
components inside the unit. Refer all servicing to  
your nearest TOA dealer.  
• No objects filled with liquids, such as vases, shall  
be placed on the unit. If they accidentally spill into  
the unit, this may cause a fire or electric shock.  
• Make sure that the volume control is set to  
minimum position before power is switched on.  
Loud noise produced at high volume when power is  
switched on can impair hearing.  
• Do not insert nor drop metallic objects or  
flammable materials in the ventilation slots of the  
unit's cover, as this may result in fire or electric  
shock.  
• Do not operate the unit for an extended period of  
time with the sound distorting. This is an indication  
of a malfunction, which in turn can cause heat to  
generate and result in a fire.  
• Contact your TOA dealer as to the cleaning. If dust  
is allowed to accumulate in the unit over a long  
period of time, a fire or damage to the unit may  
result.  
CAUTION  
Indicates a potentially hazardous situation which,  
if mishandled, could result in moderate or minor  
personal injury, and/or property damage.  
• If dust accumulates on the power supply plug or in  
the wall AC outlet, a fire may result. Clean it  
periodically. In addition, insert the plug in the wall  
outlet securely.  
When Installing the Unit  
• Never plug in nor remove the power supply plug  
with wet hands, as doing so may cause electric  
shock.  
• Switch off the power, and unplug the power supply  
plug from the AC outlet for safety purposes when  
cleaning or leaving the unit unused for 10 days or  
more. Doing otherwise may cause a fire or electric  
shock.  
• When unplugging the power supply cord, be sure  
to grasp the power supply plug; never pull on the  
An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in  
the electrical installation of the building.  
ATTENTION  
L'appareil ne doit pas être exposé aux éclaboussures ou écoulements et tous objets remplis de liquide, tels  
que vases, ne doivent pas être sur l’appareil.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. GENERAL DESCRIPTION  
Equipped with 6 LINE/MIC selectable inputs, 2 LINE inputs and 1 MODULE input, the A-706, A-712, and A-  
724 PA amplifiers are designed to suit PA system applications such as announcements, BGM and  
broadcasting in churches, large rooms and factories.  
4. FEATURES  
Power output of 60 W (A-706), 120 W (A-712), and 240 W (A-724).  
Mute Receive function assignable to all inputs, and Mute Send function assignable to Inputs 1 3 and Mute  
input.  
An equalizer or other signal processor connectable between PWR AMP IN and PRE AMP OUT terminals to  
make fine adjustment of sound.  
Tone controls (bass and treble).  
Output level meter.  
Master volume control for adjusting overall input signal level.  
Microphone gain trims for adjusting MIC level on Inputs 1 6.  
5. NOMENCLATURE AND FUNCTIONS  
[Front]  
3
4
5
1 2  
6
7
8
This figure represents the A-724.  
1. Power switch [POWER]  
6. Bass control [BASS]  
Press to turn ON the power.  
Press again to turn the power OFF.  
Adjusts bass response. Turn clockwise to increase  
bass output, and counterclockwise to decrease it.  
The center position provides flat characteristics.  
2. Power indicator  
Lights green when the power is switched on.  
7. Treble control [TREBLE]  
Adjusts treble response. Turn clockwise to  
increase treble output, and counterclockwise to  
decrease it. The center position provides flat  
characteristics.  
3. Input 1 – 8 volume controls [INPUT 1 – 8]  
Adjust the corresponding input signal levels. Turn  
each control clockwise to increase and  
counterclockwise to decrease the level.  
8. Module input volume control [MODULE]  
Adjusts the signal level of the module input on the  
rear panel. Turn the control clockwise to increase  
and counterclockwise to decrease the level.  
4. Master volume control [MASTER]  
Adjusts the overall signal level. Turn the control  
clockwise to increase and counterclockwise to  
decrease the level.  
5. LED level meter  
Indicates an output level.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
[Rear]  
9
10  
11 12  
13  
14 15 16  
17  
19  
20 21  
22  
18  
This figure represents the A-724.  
9. AC inlet  
Note  
Connect the supplied power cord.  
Avoid assigning both functions to the same input.  
(1) Mute Receive assignment switches  
[MUTE RECEIVE (INPUT CH)]  
10. Remote control connector  
Removable terminal block.  
Allow all inputs (INPUT 1 8 and Module) to be  
assigned to Mute Receive function.  
(1) Remote volume control terminals  
[REMOTE VOLUME]  
(2) Mute Send assignment switches  
[MUTE SEND (INPUT CH)]  
Connecting a 10 klinear taper volume control  
across these terminals will allow remote control  
of preamplifier output and speaker output levels.  
Allow the inputs 1 3 and Module input to be  
assigned to Mute Send function.  
(2) Power remote control terminals  
[POWER REMOTE]  
14. Function switches  
Allows remote control of the unit's power  
ON/OFF.  
(1) Phantom power ON/OFF switch  
[PHANTOM ON, OFF]  
No-voltage make contact input.  
Turns on or off the phantom power for the  
corresponding input. This switch is valid only  
when the LINE/MIC selector switch is set to the  
MIC position.  
(3) Mute control terminals [MUTE CONTROL]  
Shorting these terminals mutes the Mute  
Receive inputs (the inputs set to be muted).  
The mute control works regardless of whether or  
not there is a signal to a Mute Send input (the  
input set to activate muting).  
(2) LINE/MIC selector switch [LINE, MIC]  
Selects the input sensitivity of LINE or MIC as  
follows:  
LINE: 10 dB  
11. Mute sensitivity control [MUTE SENSE]  
Adjusts the threshold level in a range of 36 dB  
for the Mute Send inputs to activate the mute  
function. Turn clockwise to increase the  
threshold level (lower sensitivity), and  
counterclockwise to decrease the level (higher  
sensitivity).  
MIC: 70 to 50 dB, adjustable with the  
Microphone gain trimmer (15).  
15. Microphone gain trims [MIC TRIM]  
Adjust the microphone input gain for the inputs  
set to MIC.  
16. Input 1 – 6 connectors [INPUT 1 – 6]  
10 dB (LINE) or 70 to 50 dB (MIC)  
selectable, 600 , balanced, removable terminal  
blocks.  
12. Preamplifier output jack [PRE AMP OUT]  
0 dB, 600 , unbalanced RCA jack. Outputs all  
input signals. Connects to a signal processor  
such as a limiter or equalizer. (Refer to p. 7.)  
Either LINE or MIC level can be selected by the  
Function switch (14).  
13. Mute assignment switches  
When MIC level is selected, the input sensitivity  
can be adjusted from 70 to 50 dB with the  
Microphone gain trim (15).  
The inputs 2 and 3, which are electronically  
balanced, can be converted into transformer-  
balanced type by using optional transformers IT-  
455.  
[MUTE ASSIGNMENT]  
Assign the individual inputs to Mute Receive  
(inputs to be muted) or Mute Send (inputs to  
activate muting) function. When a signal enters a  
Mute Send input, Mute Receive inputs are all  
muted.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
17. Module input slot  
21. Power amplifier input jack [PWR AMP IN]  
0 dB, 600 , unbalanced RCA jack. Accepts  
output signals from the signal processor  
connected to the Preamplifier output jack (12).  
(Refer to p. 7.)  
Accepts TOA's 900 series module.  
18. Functional ground terminal  
Hum noise may be generated when external  
equipment is connected to the unit. Connecting  
this terminal to the functional ground terminal of  
the external equipment may reduce the hum  
noise.  
Inserting an RCA plug disconnects the internal  
power amplifier section from the preamplifier  
section.  
22. Input 7 and 8 jacks [INPUT 7, 8]  
Note: This terminal is not for protective earth.  
10 dB, 10 k, unbalanced RCA jacks. Accept  
output signals from external equipment.  
19. Speaker output terminals [SP OUT]  
4 , 25 V and 70 V outputs, removable terminal  
block. Connects to speakers.  
20. Recording output jacks [REC OUT]  
0 dB, 600 , unbalanced RCA jacks. Output all  
input signals before they enter the master  
volume control. Connect a cassette deck, etc.  
when recording the broadcast contents.  
6. CONNECTIONS  
6.1. Speaker Connections  
COM 425 V 70 V  
COM 425 V 70 V  
COM 425 V 70 V  
25 V LINE  
70 V LINE  
Total impedance  
10 (A-706)  
5.2 (A-712)  
2.6 (A-724)  
Total impedance  
83 (A-706)  
42 (A-712)  
21 (A-724)  
4 16 Ω  
25 V Line  
70 V Line  
Notes  
Do not use both the 4 , 25 V and 70 V terminals at the same time.  
Impedances indicated in the figures represent the total speaker system (load) impedances.  
6.2. Remote Volume Control Connection  
The external volume control can remotely adjust the  
signal level at post-master volume control.  
When performing the remote volume control, adjust  
MUTE  
CONTROL  
the master volume control in advance noting that its  
setting limits the maximum signal level adjustable  
with the volume control. Be sure to avoid turning fully  
Volume control  
10 k(linear-taper)  
down the master volume control.  
REMOTE  
POWER  
VOLUME REMOTE  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
6.3. Remote Power ON/OFF Control Connection  
To perform this control, be sure to turn the power switch OFF.  
Shorting the power remote control terminals turns the power on, and  
opening them turns the power off.  
With the power switch ON, the power on/off cannot be remotely  
controlled.  
MUTE  
CONTROL  
REMOTE  
POWER  
VOLUME REMOTE  
6.4. Mute Control Connection  
MUTE  
CONTROL  
Shorting the mute control terminals mutes the Mute Receive inputs (the  
inputs set to be muted).  
Note  
The mute control works regardless of whether or not there is a signal to  
a Mute Send input (the input set to activate muting).  
REMOTE  
VOLUME REMOTE  
POWER  
6.5. External Equipment Connection to the PRE AMP OUT and PWR AMP IN Terminals  
By connecting a signal processor such as an  
equalizer or limiter between the preamplifier section  
(PRE AMP OUT) and the power amplifier section  
PRE AMP OUT  
A-700 series  
(PWR AMP IN) of the A-700 series, signals can be  
PWR AMP IN  
tailored for desired sound output.  
Note  
Equalizer, limiter, etc.  
Inserting an RCA plug into the PWR AMP IN  
OUT IN  
terminal disconnects the internal power amplifier  
section from the preamplifier section.  
7. INSTALLATION  
To prevent the internal temperature rise, keep the unit at least 10 cm away from objects that may obstruct air  
flow.  
Over 10 cm  
Over 10 cm  
Over 10 cm  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. RACK MOUNTING  
To mount the unit in a standard 19" equipment rack, use the optional MB-25B Rack Mounting Bracket.  
Attach the MB-25B to the unit using the supplied 4 screws. When using other screws, each screw must be  
shorter than 16 mm.  
M4 x 16 Machine screw included in MB-25B  
MB-25B  
9. CONTROL SETTINGS  
Output levels are adjustable with individual volume controls.  
For music play or announcements, adjust the corresponding  
volume control so that the red indicator doesn't light. Note  
that the sound quality is downgraded when the red indicator  
remains lit.  
2
T
U
IMP  
1
T
U
P
IN  
S
S
A
B
To prevent the accidental change of the settings of input  
volume and tone (Bass and Treble) controls, remove their  
knobs after setting them to the desired position and attach  
the supplied or optional YA-920 Volume Control Covers  
instead.  
YA-920  
Control knob  
10. DIMENSIONAL DIAGRAM (Applicable to all models)  
Unit: mm  
18  
326.5  
7
420  
This figure represents the A-724.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
11. BLOCK DIAGRAM  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
12. SPECIFICATIONS  
[A-706]  
Power Source  
120 V AC, 60 Hz  
60 W  
Rated Output  
Power/Current Consumption  
155 W (rated output), 68 W (based on UL60065),  
under 250 mA (when power switch is OFF)  
Frequency Response  
Distortion  
50 20,000 Hz ( 3 dB)  
Under 2% at 1 kHz, rated power  
Input  
INPUT 1 6: 70 to 50 dB*, 600 (MIC)/10 dB*, 600 (LINE)  
INPUT 1:  
Transformer-balanced, removable terminal block (3 pins)  
INPUT 2 6: Electronically-balanced, removable terminal block (3 pins)  
Note: Each of INPUT 2 and 3 can be converted into transformer-  
balanced type by using an optional transformer IT-455.  
INPUT 7 8 (LINE): 10 dB*, 10 k, unbalanced, RCA jack  
MODULE:  
PWR AMP IN:  
10 dB*, 10 kΩ  
0 dB*, 10 k, unbalanced, RCA jack  
(An equalizer or other signal processor connectable between PRE AMP  
OUT and PWR AMP IN terminals)  
Output  
REC OUT:  
0 dB*, 600 , unbalanced, RCA jack  
PRE AMP OUT: 0 dB*, 600 , unbalanced, RCA jack  
SPEAKER OUT: 70 V line (83 ), 25 V line (10 ), and 4 16 ,  
removable terminal block (4 pins)  
Phantom Power (+23 V DC)  
ON or OFF for each INPUT 1 6 (MIC input) with switch setting  
S/N Ratio  
(Band pass: 20 20,000 Hz)  
Over 55 dB (INPUT 1 6, mic trim volume: max., 600 terminated)  
Over 70 dB (INPUT 1 6, mic trim volume: min., 600 terminated)  
Over 76 dB (Master volume: max.)  
Over 90 dB (All input volume: min.)  
Tone Control  
Control Input  
Bass: 10 dB at 100 Hz, Treble: 10 dB at 10 kHz  
REMOTE VOLUME: Removable terminal block  
POWER REMOTE: No-voltage make contact input, removable terminal  
block, Open voltage: Under 14 V DC, Short-circuit:  
Under 0.5 mA  
MUTE CONTROL: No-voltage make contact input, removable terminal  
block, Open voltage: Under 17 V DC, Short-circuit:  
Under 1.5 mA  
Indicator  
5-point LED output level meter, Power indicator LED  
Operating Temperature  
Finish  
10°C to +40°C  
Panel: ABS resin, black, hair line  
Case: Steel plate, black  
Dimensions  
Weight  
420 (w) x 107.7 (h) x 351.5 (d) mm  
9.5 kg  
* 0 dB = 1 V  
Note: The design and specifications are subject to change without notice for improvement.  
• Accessories  
AC power cord (2 m) ........................................ 1  
Removable terminal plug (4 pins) .................... 1  
Removable terminal plug (6 pins) .................... 1  
Removable terminal plug (3 pins) .................... 6  
Volume control cover YA-920 .......................... 4  
• Optional products  
Input transformer: IT-455  
Rack mounting bracket: MB-25B  
Volume control cover: YA-920  
900 series module  
Available as a service part with the  
order code 114-03-120-40.  
Additionally needed is the insulating  
sheet also available as a service part  
with 131-27-700-90.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[A-712]  
Power Source  
120 V AC, 60 Hz  
120 W  
Rated Output  
Power/Current Consumption  
285 W (rated output), 110 W (based on UL60065),  
under 400 mA (when power switch is OFF)  
Frequency Response  
Distortion  
50 20,000 Hz ( 3 dB)  
Under 2% at 1 kHz, rated power  
Input  
INPUT 1 6: 70 to 50 dB*, 600 (MIC)/10 dB*, 600 (LINE)  
INPUT 1:  
Transformer-balanced, removable terminal block (3 pins)  
INPUT 2 6: Electronically-balanced, removable terminal block (3 pins)  
Note: Each of INPUT 2 and 3 can be converted into transformer-  
balanced type by using an optional transformer IT-455.  
INPUT 7 8 (LINE): 10 dB*, 10 k, unbalanced, RCA jack  
MODULE:  
PWR AMP IN:  
10 dB*, 10 kΩ  
0 dB*, 10 k, unbalanced, RCA jack  
(An equalizer or other signal processor connectable between PRE AMP  
OUT and PWR AMP IN terminals)  
Output  
REC OUT:  
0 dB*, 600 , unbalanced, RCA jack  
PRE AMP OUT: 0 dB*, 600 , unbalanced, RCA jack  
SPEAKER OUT: 70 V line (42 ), 25 V line (5.2 ), and 4 16 ,  
removable terminal block (4 pins)  
Phantom Power (+23 V DC)  
ON or OFF for each INPUT 1 6 (MIC input) with switch setting  
S/N Ratio  
(Band pass: 20 20,000 Hz)  
Over 55 dB (INPUT 1 6, mic trim volume: max., 600 terminated)  
Over 70 dB (INPUT 1 6, mic trim volume: min., 600 terminated)  
Over 76 dB (Master volume: max.)  
Over 90 dB (All input volume: min.)  
Tone Control  
Control Input  
Bass: 10 dB at 100 Hz, Treble: 10 dB at 10 kHz  
REMOTE VOLUME: Removable terminal block  
POWER REMOTE: No-voltage make contact input, removable terminal  
block, Open voltage: Under 14 V DC, Short-circuit:  
Under 0.5 mA  
MUTE CONTROL: No-voltage make contact input, removable terminal  
block, Open voltage: Under 17 V DC, Short-circuit:  
Under 1.5 mA  
Indicator  
5-point LED output level meter, Power indicator LED  
Operating Temperature  
Finish  
10°C to +40°C  
Panel: ABS resin, black, hair line  
Case: Steel plate, black  
Dimensions  
Weight  
420 (w) x 107.7 (h) x 351.5 (d) mm  
12 kg  
* 0 dB = 1 V  
Note: The design and specifications are subject to change without notice for improvement.  
• Accessories  
AC power cord (2 m) ........................................ 1  
Removable terminal plug (4 pins) .................... 1  
Removable terminal plug (6 pins) .................... 1  
Removable terminal plug (3 pins) .................... 6  
Volume control cover YA-920 .......................... 4  
• Optional products  
Input transformer: IT-455  
Rack mounting bracket: MB-25B  
Volume control cover: YA-920  
900 series module  
Available as a service part with the  
order code 114-03-120-40.  
Additionally needed is the insulating  
sheet also available as a service part  
with 131-27-700-90.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[A-724]  
Power Source  
120 V AC, 60 Hz  
240 W  
Rated Output  
Power/Current Consumption  
565 W (rated output), 215 W (based on UL60065),  
under 60 mA (when power switch is OFF)  
Frequency Response  
Distortion  
50 20,000 Hz ( 3 dB)  
Under 2% at 1 kHz, rated power  
Input  
INPUT 1 6: 70 to 50 dB*, 600 (MIC)/10 dB*, 600 (LINE)  
INPUT 1:  
Transformer-balanced, removable terminal block (3 pins)  
INPUT 2 6: Electronically-balanced, removable terminal block (3 pins)  
Note: Each of INPUT 2 and 3 can be converted into transformer-  
balanced type by using an optional transformer IT-455.  
INPUT 7 8 (LINE): 10 dB*, 10 k, unbalanced, RCA jack  
MODULE:  
PWR AMP IN:  
10 dB*, 10 kΩ  
0 dB*, 10 k, unbalanced, RCA jack  
(An equalizer or other signal processor connectable between PRE AMP  
OUT and PWR AMP IN terminals)  
Output  
REC OUT:  
0 dB*, 600 , unbalanced, RCA jack  
PRE AMP OUT: 0 dB*, 600 , unbalanced, RCA jack  
SPEAKER OUT: 70 V line (21 ), 25 V line (2.6 ), and 4 16 ,  
removable terminal block (4 pins)  
Phantom Power (+23 V DC)  
ON or OFF for each INPUT 1 6 (MIC input) with switch setting  
S/N Ratio  
(Band pass: 20 20,000 Hz)  
Over 55 dB (INPUT 1 6, mic trim volume: max., 600 terminated)  
Over 70 dB (INPUT 1 6, mic trim volume: min., 600 terminated)  
Over 76 dB (Master volume: max.)  
Over 90 dB (All input volume: min.)  
Tone Control  
Control Input  
Bass: 10 dB at 100 Hz, Treble: 10 dB at 10 kHz  
REMOTE VOLUME: Removable terminal block  
POWER REMOTE: No-voltage make contact input, removable terminal  
block, Open voltage: Under 14 V DC, Short-circuit:  
Under 0.5 mA  
MUTE CONTROL: No-voltage make contact input, removable terminal  
block, Open voltage: Under 17 V DC, Short-circuit:  
Under 1.5 mA  
Indicator  
5-point LED output level meter, Power indicator LED  
Operating Temperature  
Finish  
10°C to +40°C  
Panel: ABS resin, black, hair line  
Case: Steel plate, black  
Dimensions  
Weight  
420 (w) x 107.7 (h) x 351.5 (d) mm  
13.5 kg  
* 0 dB = 1 V  
Note: The design and specifications are subject to change without notice for improvement.  
• Accessories  
AC power cord (2 m) ........................................ 1  
Removable terminal plug (4 pins) .................... 1  
Removable terminal plug (6 pins) .................... 1  
Removable terminal plug (3 pins) .................... 6  
Volume control cover YA-920 .......................... 4  
• Optional products  
Input transformer: IT-455  
Rack mounting bracket: MB-25B  
Volume control cover: YA-920  
900 series module  
Available as a service part with the  
order code 114-03-120-40.  
Additionally needed is the insulating  
sheet also available as a service part  
with 131-27-700-90.  
133-12-920-9A  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Technicolor Thomson Switch TS 870 User Manual
Texas Instruments Stereo Amplifier SLOU121 User Manual
Toshiba Flat Panel Television 20AS24 User Manual
Toshiba Network Hardware IK WP41A User Manual
Toshiba Satellite TV System P205 S6297 User Manual
TRENDnet Network Router TEW 231BRP User Manual
Tricity Bendix Clothes Dryer TM 200 User Manual
Uniden Cordless Telephone CXA 15698 User Manual
ViewSonic Projector PJD5134 User Manual
Visual Land MP3 Player 507K User Manual