INSTRUCTION MANUAL
INTERFACE UNIT
C-IF500
TABLE OF CONTENTS
1. SAFETY PRECAUTIONS .......................... 2
2. GENERAL DESCRIPTION ........................ 3
3. FEATURES ................................................ 3
5. CONNECTIONS
5.1. System Examples ................................. 5
5.2. Connecting 32 or
More Combination Cameras ................ 6
5.3. Star Connection .................................... 7
4. NOMENCLATURE AND FUNCTIONS
Front ........................................................... 4
Rear ............................................................ 4
6. SPECIFICATIONS ...................................... 8
Please follow the instructions in this manual to obtain the optimum results from this unit.
We also recommend that you keep this manual handy for future reference.
Download from Www.Somanuals.com. All Manuals Search And Download.
Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.
CAUTION
When Installing the Unit
• Never plug in nor remove the power supply cord with wet hands, as doing so may cause electric shock.
• When unplugging the power supply cord, be sure to grasp the power supply plug; never pull on the cord
itself. Operating the unit with a damaged power supply cord may cause a fire or electric shock.
• When moving the unit, be sure to remove its power supply cord from the unit. Moving the unit with the power
cord connected may cause damage to the power cord, resulting in fire or electric shock. When removing the
power cord, be sure to hold its plug to pull.
• Do not block the ventilation slots in the unit's cover. Doing so may cause heat to build up inside the unit and
result in fire.
• Avoid installing the unit in humid or dusty locations, in locations exposed to the direct sunlight, near the
heaters, or in locations generating sooty smoke or steam as doing otherwise may result in fire or electric
shock.
When the Unit is in Use
• Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal
injury and/or property damage. In addition, the object itself may fall off and cause injury and/or damage.
• Use the dedicated AC adapter for the unit. Note that the use of other adapter may cause a fire.
• Contact your TOA dealer as to the cleaning. If dust is allowed to accumulate in the unit over a long period of
time, a fire or damage to the unit may result.
• If dust accumulates on the power supply plug or in the wall AC outlet, a fire may result. Clean it periodically.
In addition, insert the plug in the wall outlet securely.
• Unplug the power cord from the unit for safety purposes when cleaning or leaving the unit unused for 10
days or more. Doing otherwise may cause a fire or electric shock.
C-IF500 complies with Part 15 of the FCC Rules.
Note
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
Modifications
Any modifications made to this device that are not approved by TOA Corporation may void the authority
granted to the user by the FCC to operate this equipment.
2. GENERAL DESCRIPTION
The TOA C-IF500 Interface Unit is a splitter for control signals to be used when controlling 32 or more TOA
Combination Cameras connected to the TOA C-RM500 Remote Controller.
3. FEATURES
• Can split the C-RM500 Remote Controller's control signal into 4 signals.
• Can convert the C-RM500's control signal level into the RS-232C signal level.
• Connecting the unit between the C-RM500 and the Combination camera permits star connection between
the Remote Controller and camera.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
4. NOMENCLATURE AND FUNCTIONS
[Front]
MODE
TX
RX
POWER
ON
1
2
3
4
INTERFACE UNIT C-IF500
2
3
4
1
1. Power indicator [POWER]
3. Data transmission indicator [TX]
Lights when data is transmitted from the Slave
terminal.
Lights when the power is supplied.
2. Transfer rate setting switch [MODE]
Sets the transfer rate of the data to be transmitted
via the unit.
4. Data reception indicator [RX]
Lights when data is received from the Slave
terminal.
Transfer Rate
38400 bps
19200 bps
9600 bps
1
2
3
4
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
OFF
OFF
4800 bps
OFF
[Rear]
DC IN 12V DC IN
12V
MASTER
SLAVE
IN
GND
OUT
GND
RS-232C
A
B
GND
C
GND
D
GND
GND
GND GND
TERMINATION
OFF ON
5
6 7
8
9
10
11
5. AC adapter input terminal *
9. Terminating resistance switch [TERMINATION]
Set this switch to ON when connecting the C-
RM500. However, there is a case that the switch
is used in the OFF position depending on the
connection method.
Connect the AC adapter to this terminal.
6. 12 V DC power input terminal *
Please connect with the power supply other than
the AC adapter by the cable that attached the
supplied clamp filter.
Refer to p. 6 for details.
10. RS-232C terminal [SLAVE/RS-232C]
Converts the data received at the Master
Connection Terminal into the RS-232C signal
level and sends out the converted signal. The
RS-232C Terminal also converts an input signal
to the RS-232C terminal into the RS-485 control
signal, and outputs the converted signal from the
Master Connection Terminal.
2turn
12V
IN GND
+
+
-
power supply
clamp filter
(Please attach a clamp filter to the nearest
possible position of this controller.)
7. Ground Terminal [GND]
Please be sure to ground.
11. Slave connection terminal [SLAVE/A – D]
Splits an input signal to the Master Connection
Terminal into 4 and sends out the split signals.
Caution
Up to 31 C-CC501, C-CC504, C-CC551, or C-
CC554 Combination Camera can be connected to
each Slave Terminal A-D.
8. Master connection terminal [MASTER]
Connects to the C-RM500 Remote Controller to
split the control data transmitted from the C-
RM500.
* Connect the DC power supply of 12 V/over 100 mA, which suited CE standard to either input terminal.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
[Bottom]
INTERFACE UNIT
model C-IF500 120
12V
100mA Class2
12. Rating label
TOA Corporation
MADE IN JAPAN
SER. 02A4000001
12
5. CONNECTIONS
5.1. System Examples
[Example 1]
Monitor TV
Smart switcher
Combination camera
C-IF500
Remote controller
Combination camera
[Example 2]
Combination camera
Monitor TV
Multi-switcher
C-IF500
Remote controller
5
Download from Www.Somanuals.com. All Manuals Search And Download.
5.2. Connecting 32 or More Combination Cameras
Connect the Combination camera's control cable to the unit's Slave Connection Terminal, making sure to
match their polarities.
Remote controller
C-RM500
Camera control terminal
GND
Shielded twisted-pair cable
Termination switch: ON
C-IF500
MASTER
SLAVE
IN
GND
OUT
GND
A
B
C
GND
D
GND
GND
GND
TERMINATION
OFF ON
Caution
Up to 31 C-CC501, C-CC504, C-CC551, or
C-CC554 Combination Camera can be
connected to each Slave Terminal A-D.
Combination
camera
Ch 1
Ch 2
Ch 31
Termination switch
OFF
Termination switch
OFF
Termination switch
ON
Combination
camera
Ch 32
Termination switch
OFF
Ch 33
Ch 62
Termination switch
OFF
Termination switch
ON
[Connection cables]
• Recommended cable type: CPEV-S type (shielded twisted-pair cable) thicker than 0.65 mm in diameter.
• If multiple cameras are connected to a single terminal, the total of each cable distance between connected
equipment must be 1.2 km or less.
Interface unit
C-IF500
Combination
camera
Combination
camera
Combination
camera
a
b
c
<
a + b + c 1.2 km
[Termination switch setting]
• Set the unit's termination switch to ON when the unit and the C-RM500 Remote Controller are connected in
a matched pair in the system.
• Make sure that the termination switches of the cameras connected to the system are set as follows.
Cameras other than the last connected camera: Termination switch OFF
Last connected camera:
Termination switch ON
Interface unit
C-IF500
Combination
camera
Combination
camera
Combination
camera
Terminal switch
OFF
Terminal switch
OFF
Terminal switch
ON
6
Download from Www.Somanuals.com. All Manuals Search And Download.
5.3. Star Connection
Connect the Combination camera's control cable to the unit's Slave Connection Terminal, making sure to
match their polarities.
Remote controller
C-RM500
Camera control terminal
GND
Shielded twisted-pair cable
Termination switch: OFF
C-IF500
MASTER
OUT
GND
SLAVE
IN
GND
A
B
C
GND
D
GND
GND
GND
TERMINATION
OFF ON
Combination camera
Ch 1
Ch 2
Ch 3
Ch 4
Termination switch
ON
Termination switch
ON
Termination switch
ON
Termination switch
ON
Termination switch: ON
C-IF500
MASTER
SLAVE
IN
GND
OUT
GND
A
B
C
GND
D
GND
GND
GND
TERMINATION
OFF ON
Combination camera
Ch 5
Ch 6
Ch 7
Ch 8
Termination switch
ON
Termination switch
ON
Termination switch
ON
Termination switch
ON
[Connection cables]
• Recommended cable type: CPEV-S type (shielded twisted-pair cable) thicker than 0.65 mm in diameter.
The maximum cable distance between the Combination camera and each Slave Connection terminal is 1.2 km.
•
[Termination switch setting]
• Set the termination switches of all connected cameras to ON.
• Make sure that the unit's termination switch is set as follows.
Units other than the last connected unit: Termination switch OFF
Last connected unit:
Termination switch ON
7
Download from Www.Somanuals.com. All Manuals Search And Download.
6. SPECIFICATIONS
Power Source
12 V DC
Current Consumption
External Control
100 mA
Master: RS-485, screwless connector,
terminating resistance (100 Ω) switch ON/OFF
Slave*1: 4 channel, RS-485, screwless connector, RS-232C,
D-sub connector (9-pin, male)
Power LED indicator, communication LED indicators (TX, RX)
RS-485: 1.2 km*2
Display
Maximum Cable Distance
RS-232C: 10 m
Communication Speed
Operating Temperature
4800 bps, 9600 bps, 19200 bps, 38400 bps
–10 to +50°C
Operating Humidity
Finish
Under 90% (no due condensation produced)
Panel: Aluminum, black (30% glossy), paint
Case: Pre-coated steel plate, black (30% glossy)
210 (w) x 46 (h) x 284.1 (d) mm
Dimensions
Weight
1.4 kg
Notes
• The unit cannot be used in the system with the transmission/reception switching interval of 2 bytes or less or
where transmission signals could be simultaneously sent out from multiple slave terminals.
• The design and specifications are subject to change without notice for improvement.
*1 Communications cannot be made between slave terminals.
*2 Applies to the system where the unit and Combination camera are connected in a matched pair.
Represents the total of connected cable distances if multiple Combination cameras or Interface units are
connected in the system (when the CPEV-S cable thicker than 0.65 mm in diameter is used).
• Optional Equipment
MB-15B-BK Rack mounting bracket (for rack mounting one C-IF500 unit)
MB-15B-J
Rack mounting bracket (for rack mounting two C-IF500 units)
Printed in Japan
133-12-742-1E