TOA Electronics Network Card C IF500 User Manual

INSTRUCTION MANUAL  
INTERFACE UNIT  
C-IF500  
TABLE OF CONTENTS  
1. SAFETY PRECAUTIONS .......................... 2  
2. GENERAL DESCRIPTION ........................ 3  
3. FEATURES ................................................ 3  
5. CONNECTIONS  
5.1. System Examples ................................. 5  
5.2. Connecting 32 or  
More Combination Cameras ................ 6  
5.3. Star Connection .................................... 7  
4. NOMENCLATURE AND FUNCTIONS  
Front ........................................................... 4  
Rear ............................................................ 4  
6. SPECIFICATIONS ...................................... 8  
Please follow the instructions in this manual to obtain the optimum results from this unit.  
We also recommend that you keep this manual handy for future reference.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Indicates a potentially hazardous situation which, if mishandled, could  
result in moderate or minor personal injury, and/or property damage.  
CAUTION  
When Installing the Unit  
• Never plug in nor remove the power supply cord with wet hands, as doing so may cause electric shock.  
• When unplugging the power supply cord, be sure to grasp the power supply plug; never pull on the cord  
itself. Operating the unit with a damaged power supply cord may cause a fire or electric shock.  
• When moving the unit, be sure to remove its power supply cord from the unit. Moving the unit with the power  
cord connected may cause damage to the power cord, resulting in fire or electric shock. When removing the  
power cord, be sure to hold its plug to pull.  
• Do not block the ventilation slots in the unit's cover. Doing so may cause heat to build up inside the unit and  
result in fire.  
• Avoid installing the unit in humid or dusty locations, in locations exposed to the direct sunlight, near the  
heaters, or in locations generating sooty smoke or steam as doing otherwise may result in fire or electric  
shock.  
When the Unit is in Use  
• Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal  
injury and/or property damage. In addition, the object itself may fall off and cause injury and/or damage.  
• Use the dedicated AC adapter for the unit. Note that the use of other adapter may cause a fire.  
• Contact your TOA dealer as to the cleaning. If dust is allowed to accumulate in the unit over a long period of  
time, a fire or damage to the unit may result.  
• If dust accumulates on the power supply plug or in the wall AC outlet, a fire may result. Clean it periodically.  
In addition, insert the plug in the wall outlet securely.  
• Unplug the power cord from the unit for safety purposes when cleaning or leaving the unit unused for 10  
days or more. Doing otherwise may cause a fire or electric shock.  
C-IF500 complies with Part 15 of the FCC Rules.  
Note  
This equipment has been tested and found to comply with the limits for a Class A digital device,  
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection  
against harmful interference when the equipment is operated in a commercial environment. This  
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in  
accordance with the instruction manual, may cause harmful interference to radio communications.  
Operation of this equipment in a residential area is likely to cause harmful interference in which case the  
user will be required to correct the interference at his own expense.  
Modifications  
Any modifications made to this device that are not approved by TOA Corporation may void the authority  
granted to the user by the FCC to operate this equipment.  
2. GENERAL DESCRIPTION  
The TOA C-IF500 Interface Unit is a splitter for control signals to be used when controlling 32 or more TOA  
Combination Cameras connected to the TOA C-RM500 Remote Controller.  
3. FEATURES  
• Can split the C-RM500 Remote Controller's control signal into 4 signals.  
• Can convert the C-RM500's control signal level into the RS-232C signal level.  
• Connecting the unit between the C-RM500 and the Combination camera permits star connection between  
the Remote Controller and camera.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. NOMENCLATURE AND FUNCTIONS  
[Front]  
MODE  
TX  
RX  
POWER  
ON  
1
2
3
4
INTERFACE UNIT C-IF500  
2
3
4
1
1. Power indicator [POWER]  
3. Data transmission indicator [TX]  
Lights when data is transmitted from the Slave  
terminal.  
Lights when the power is supplied.  
2. Transfer rate setting switch [MODE]  
Sets the transfer rate of the data to be transmitted  
via the unit.  
4. Data reception indicator [RX]  
Lights when data is received from the Slave  
terminal.  
Transfer Rate  
38400 bps  
19200 bps  
9600 bps  
1
2
3
4
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
ON  
ON  
OFF  
OFF  
4800 bps  
OFF  
[Rear]  
DC IN 12V DC IN  
12V  
MASTER  
SLAVE  
IN  
GND  
OUT  
GND  
RS-232C  
A
B
GND  
C
GND  
D
GND  
GND  
GND GND  
TERMINATION  
OFF ON  
5
6 7  
8
9
10  
11  
5. AC adapter input terminal *  
9. Terminating resistance switch [TERMINATION]  
Set this switch to ON when connecting the C-  
RM500. However, there is a case that the switch  
is used in the OFF position depending on the  
connection method.  
Connect the AC adapter to this terminal.  
6. 12 V DC power input terminal *  
Please connect with the power supply other than  
the AC adapter by the cable that attached the  
supplied clamp filter.  
Refer to p. 6 for details.  
10. RS-232C terminal [SLAVE/RS-232C]  
Converts the data received at the Master  
Connection Terminal into the RS-232C signal  
level and sends out the converted signal. The  
RS-232C Terminal also converts an input signal  
to the RS-232C terminal into the RS-485 control  
signal, and outputs the converted signal from the  
Master Connection Terminal.  
2turn  
12V  
IN GND  
+
+
-
power supply  
clamp filter  
(Please attach a clamp filter to the nearest  
possible position of this controller.)  
7. Ground Terminal [GND]  
Please be sure to ground.  
11. Slave connection terminal [SLAVE/A – D]  
Splits an input signal to the Master Connection  
Terminal into 4 and sends out the split signals.  
Caution  
Up to 31 C-CC501, C-CC504, C-CC551, or C-  
CC554 Combination Camera can be connected to  
each Slave Terminal A-D.  
8. Master connection terminal [MASTER]  
Connects to the C-RM500 Remote Controller to  
split the control data transmitted from the C-  
RM500.  
* Connect the DC power supply of 12 V/over 100 mA, which suited CE standard to either input terminal.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
[Bottom]  
INTERFACE UNIT  
model C-IF500 120  
12V  
100mA Class2  
12. Rating label  
TOA Corporation  
MADE IN JAPAN  
SER. 02A4000001  
12  
5. CONNECTIONS  
5.1. System Examples  
[Example 1]  
Monitor TV  
Smart switcher  
Combination camera  
C-IF500  
Remote controller  
Combination camera  
[Example 2]  
Combination camera  
Monitor TV  
Multi-switcher  
C-IF500  
Remote controller  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
5.2. Connecting 32 or More Combination Cameras  
Connect the Combination camera's control cable to the unit's Slave Connection Terminal, making sure to  
match their polarities.  
Remote controller  
C-RM500  
Camera control terminal  
GND  
Shielded twisted-pair cable  
Termination switch: ON  
C-IF500  
MASTER  
SLAVE  
IN  
GND  
OUT  
GND  
A
B
C
GND  
D
GND  
GND  
GND  
TERMINATION  
OFF ON  
Caution  
Up to 31 C-CC501, C-CC504, C-CC551, or  
C-CC554 Combination Camera can be  
connected to each Slave Terminal A-D.  
Combination  
camera  
Ch 1  
Ch 2  
Ch 31  
Termination switch  
OFF  
Termination switch  
OFF  
Termination switch  
ON  
Combination  
camera  
Ch 32  
Termination switch  
OFF  
Ch 33  
Ch 62  
Termination switch  
OFF  
Termination switch  
ON  
[Connection cables]  
• Recommended cable type: CPEV-S type (shielded twisted-pair cable) thicker than 0.65 mm in diameter.  
• If multiple cameras are connected to a single terminal, the total of each cable distance between connected  
equipment must be 1.2 km or less.  
Interface unit  
C-IF500  
Combination  
camera  
Combination  
camera  
Combination  
camera  
a
b
c
<
a + b + c 1.2 km  
[Termination switch setting]  
• Set the unit's termination switch to ON when the unit and the C-RM500 Remote Controller are connected in  
a matched pair in the system.  
• Make sure that the termination switches of the cameras connected to the system are set as follows.  
Cameras other than the last connected camera: Termination switch OFF  
Last connected camera:  
Termination switch ON  
Interface unit  
C-IF500  
Combination  
camera  
Combination  
camera  
Combination  
camera  
Terminal switch  
OFF  
Terminal switch  
OFF  
Terminal switch  
ON  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
5.3. Star Connection  
Connect the Combination camera's control cable to the unit's Slave Connection Terminal, making sure to  
match their polarities.  
Remote controller  
C-RM500  
Camera control terminal  
GND  
Shielded twisted-pair cable  
Termination switch: OFF  
C-IF500  
MASTER  
OUT  
GND  
SLAVE  
IN  
GND  
A
B
C
GND  
D
GND  
GND  
GND  
TERMINATION  
OFF ON  
Combination camera  
Ch 1  
Ch 2  
Ch 3  
Ch 4  
Termination switch  
ON  
Termination switch  
ON  
Termination switch  
ON  
Termination switch  
ON  
Termination switch: ON  
C-IF500  
MASTER  
SLAVE  
IN  
GND  
OUT  
GND  
A
B
C
GND  
D
GND  
GND  
GND  
TERMINATION  
OFF ON  
Combination camera  
Ch 5  
Ch 6  
Ch 7  
Ch 8  
Termination switch  
ON  
Termination switch  
ON  
Termination switch  
ON  
Termination switch  
ON  
[Connection cables]  
• Recommended cable type: CPEV-S type (shielded twisted-pair cable) thicker than 0.65 mm in diameter.  
The maximum cable distance between the Combination camera and each Slave Connection terminal is 1.2 km.  
[Termination switch setting]  
• Set the termination switches of all connected cameras to ON.  
• Make sure that the unit's termination switch is set as follows.  
Units other than the last connected unit: Termination switch OFF  
Last connected unit:  
Termination switch ON  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. SPECIFICATIONS  
Power Source  
12 V DC  
Current Consumption  
External Control  
100 mA  
Master: RS-485, screwless connector,  
terminating resistance (100 ) switch ON/OFF  
Slave*1: 4 channel, RS-485, screwless connector, RS-232C,  
D-sub connector (9-pin, male)  
Power LED indicator, communication LED indicators (TX, RX)  
RS-485: 1.2 km*2  
Display  
Maximum Cable Distance  
RS-232C: 10 m  
Communication Speed  
Operating Temperature  
4800 bps, 9600 bps, 19200 bps, 38400 bps  
–10 to +50°C  
Operating Humidity  
Finish  
Under 90% (no due condensation produced)  
Panel: Aluminum, black (30% glossy), paint  
Case: Pre-coated steel plate, black (30% glossy)  
210 (w) x 46 (h) x 284.1 (d) mm  
Dimensions  
Weight  
1.4 kg  
Notes  
• The unit cannot be used in the system with the transmission/reception switching interval of 2 bytes or less or  
where transmission signals could be simultaneously sent out from multiple slave terminals.  
• The design and specifications are subject to change without notice for improvement.  
*1 Communications cannot be made between slave terminals.  
*2 Applies to the system where the unit and Combination camera are connected in a matched pair.  
Represents the total of connected cable distances if multiple Combination cameras or Interface units are  
connected in the system (when the CPEV-S cable thicker than 0.65 mm in diameter is used).  
• Optional Equipment  
MB-15B-BK Rack mounting bracket (for rack mounting one C-IF500 unit)  
MB-15B-J  
Rack mounting bracket (for rack mounting two C-IF500 units)  
Printed in Japan  
133-12-742-1E  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Tascam CD Player CD D4000 User Manual
Tascam CD Player LR 10 User Manual
Taylor Scale 3840BL User Manual
Traulsen Refrigerator TR35832 User Manual
Tripp Lite Network Cables N002 002 BL User Manual
Ultra Start Automobile Alarm 430 Series User Manual
Volkswagen Automobile Caravelle User Manual
VTech Cordless Telephone DS3211 2 User Manual
Vulcan Hart Electric Steamer MHB24G User Manual
Weber Gas Grill 55265 User Manual