Sun Netra CP3250
Blade Server User’s Guide
Sun Microsystems, Inc.
www.sun.com
Part No. 820-5195-11
April 2009, Revision 01
Submit comments about this document at: http://www.sun.com/hwdocs/feedback
Download from Www.Somanuals.com. All Manuals Search And Download.
1. Overview 1–1
1.6.2
1.6.3
Software Components 1–12
1.7
Technical Support and Warranty 1–13
1.7.1
1.7.2
Locating the Part Number and Serial Number Information 1–13
Viewing the Electronic Blade Server ID Information 1–14
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Hardware Installation and Service 2–1
2.1.1
2.1.2
Equipment and Operator Safety 2–2
Materials and Tools Required 2–3
2.2.1
2.2.2
Preparing for the Installation 2–4
2.2.1.1
2.2.1.3
Check Power, Thermal, Environmental, and Space
Worksheet 2–5
Installation Procedure Summary 2–6
Configuring the Hardware 2–6
2.2.2.3
Configuring the Advanced Rear Transition Module
2.2.4
(ARTM) 2–8
Connecting External I/O Cables 2–13
2.2.4.1
2.2.4.3
Connecting Cables to a System Console Running the
the Solaris OS 2–15
Netinstall Boot Device Map 2–15
2.3
Service Procedures 2–17
2.3.1
2.3.2
2.3.3
2.3.4
Hot-Swapping the Netra CP3250 Blade Server 2–17
Powering Off the Netra CP3250 Blade Server 2–17
Removing the Netra CP3250 Blade Server 2–18
Powering On the System 2–18
iv
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
2.3.6.3
Removing a DDR2 DIMM 2–23
2.3.7
2.3.8
2.3.9
Installing the Optional Compact Flash Card 2–24
Installing Optional AMC 2–27
Adding or Replacing the Battery 2–30
2.3.10 Changing Jumper Settings 2–31
2.3.10.1 Clearing the CMOS Setting Using Jumper 2 2–31
3. Hardware Architecture 3–1
3.1
3.2
3.3
3.4
3.5
Block Diagram 3–2
Intel Processors 3–3
Intel San Clemente MCH 3–3
Memory 3–4
Networking and I/O 3–5
3.5.1
3.5.2
3.5.3
3.5.4
3.5.5
3.5.6
3.5.7
3.5.8
ICH9 I/O Controller Hub 3–5
PCI Express Bus 3–5
LPC Bus Interface 3–6
Redundant BIOS 3–6
Trusted Platform Module (TPM) 3–7
IPMC 3–7
RS-232 Serial Ports 3–7
Broadcom 5715C Gigabit Ethernet 3–8
Contents
v
Download from Www.Somanuals.com. All Manuals Search And Download.
3.6
I/O Components 3–8
4. Software Configuration 4–1
4.1
4.2
4.3
4.4
Operating Systems 4–2
Software Updates 4–2
SunVTS Software 4–3
Configuring Sun Netra CP3250 blade server For 1 GbE or 10 GbE
5. Configuring and Using BIOS Firmware 5–1
5.1
About BIOS Settings 5–2
5.1.1
5.1.2
5.1.3
Navigating BIOS Screens 5–2
BIOS Option ROMs 5–2
Description of the BIOS Screens 5–3
5.2
5.3
5.4
5.5
5.6
5.7
5.8
5.9
Changing the Configuration of a BIOS Menu Item 5–3
Setting the Boot Device Using BIOS Setup Screens 5–4
Setting Supervisor and User Passwords 5–5
Resetting the System Time and System Date 5–6
Updating the BIOS 5–6
Secondary BIOS Image 5–7
Power-On Self-Test 5–8
5.10 Changing POST Options 5–9
A. BIOS Screens A–1
vi
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
B. Physical Characteristics B–1
B.3.1 Front Panel Connectors B–2
B.3.1.1
B.3.1.2
B.3.1.3
Ethernet Port B–3
USB Ports B–4
Serial Port B–5
B.3.2 AMC Connector B–5
B–9
B.3.5.1
B.3.5.2
Zone 3 (J30) Connector Pin Assignments B–10
Zone 3 (J31) Connector PIN Assignments B–11
C.1
C.2
Shelf Manager Command-Line Interface C–2
Shelf Manager CLI Commands C–3
Index Index–1
Contents
vii
Download from Www.Somanuals.com. All Manuals Search And Download.
viii
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
Figures
FIGURE 1-1
FIGURE 1-2
FIGURE 1-3
FIGURE 1-4
FIGURE 1-5
FIGURE 2-1
FIGURE 2-2
FIGURE 2-3
FIGURE 2-4
FIGURE 2-5
FIGURE 2-6
FIGURE 2-7
FIGURE 2-8
FIGURE 2-9
FIGURE 2-10
FIGURE 2-11
FIGURE 2-12
FIGURE 2-13
FIGURE 2-14
FIGURE 2-15
Jumper 2 in the Default Run Position 2–31
SW1 Default DIP Switch Settings 2–33
SW4 Default DIP Switch Settings 2–33
SW5 Default DIP Switch Settings 2–34
ix
Download from Www.Somanuals.com. All Manuals Search And Download.
FIGURE 2-16
FIGURE A-1
FIGURE A-2
FIGURE A-3
FIGURE A-4
FIGURE A-5
FIGURE A-6
FIGURE A-7
FIGURE A-8
FIGURE A-9
FIGURE A-10
FIGURE A-11
FIGURE A-12
FIGURE A-13
FIGURE A-14
FIGURE B-1
FIGURE B-2
FIGURE B-3
FIGURE B-4
FIGURE B-5
FIGURE B-6
Front Panel Serial RJ-45 Connector B–5
Power Distribution Connector (Zone 1) P10 B–6
Zone 2 Connector B–8
Zone 3 Connector B–10
x
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE 1-1
TABLE 1-2
TABLE 2-1
TABLE 2-2
TABLE 2-3
TABLE 2-4
TABLE 5-1
TABLE 5-2
TABLE B-1
TABLE B-2
TABLE B-3
TABLE B-4
TABLE B-5
TABLE B-6
TABLE B-7
TABLE B-8
TABLE B-9
TABLE B-10
TABLE C-1
Ethernet Port Connector Pin Assignments B–3
J32 Connector Pin Assignments B–12
J33 Connector Pin Assignments B–13
Zone 3 Signal Descriptions B–14
Shelf Manager CLI Command Summary C–3
xi
Download from Www.Somanuals.com. All Manuals Search And Download.
xii
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
Preface
The Sun Netra CP3250 Blade Server User’s Guide describes the hardware specifications,
function, and physical properties of the Sun Netra™ CP3250 blade server. It also
provides detailed information on the system firmware.
The Sun Netra CP3250 Blade Server User’s Guide is written for system integration
engineers, field applications and service engineers, and others involved in the
integration of this blade server into systems. This guide is written for personnel who
are familiar with the Solaris™ Operating System, the Linux operating systems and
Advanced Telecommunications Computing Architecture (ATCA) computing
environment.
How This Document Is Organized
Chapter 1 provides an overview of the Sun Netra CP3250 blade server.
Validation Test Suite (SunVTS™) software.
Appendix A provides first-level and second-level BIOS menu illustrations.
Appendix B provides information on the Sun Netra CP3250 blade server physical
characteristics.
Appendix C provides a list of the most commonly used ShMM commands.
xiii
Download from Www.Somanuals.com. All Manuals Search And Download.
Using UNIX Commands
This document might not contain information about basic UNIX commands and
procedures such as shutting down the system, booting the system, and configuring
devices. Refer to the following for this information:
®
■
Software documentation that you received with your system
Solaris™ Operating System documentation, which is at:
■
Shell Prompts
Shell
Prompt
C shell
machine-name%
C shell superuser
machine-name#
Bourne shell and Korn shell
Bourne shell and Korn shell superuser
$
#
xiv
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
Typographic Conventions
*
Typeface
Meaning
Examples
AaBbCc123
The names of commands, files,
and directories; on-screen
computer output
Edit your.loginfile.
Use ls-ato list all files.
% You have mail.
AaBbCc123
What you type, when contrasted % su
with on-screen computer output
Password:
Book titles, new words or terms, Read Chapter 6 in the User’s Guide.
AaBbCc123
words to be emphasized.
Replace command-line variables
with real names or values.
These are called class options.
You must be superuser to do this.
To delete a file, type rmfilename.
*
The settings on your browser might differ from these settings.
Related Documentation
For additional information about the Sun Netra CP3250 blade server or the Netra
CP32x0 advanced rear transition module (ARTM), refer to the following documents
The following table lists the documentation for this product. The online
documentation is available at:
Application
Title
Part Number
Format
Location
Installation
and Service
Sun Netra CP3250 Blade Server
User’s Guide (this manual)
820-5195
PDF,
HTML
Online
Pointer
Doclette
Netra CP3250 Blade Server Getting 820-5197
Started Guide
Printed, Shipkit
PDF,
HTML
Preface
xv
Download from Www.Somanuals.com. All Manuals Search And Download.
Application
Title
Part Number
Format
Location
Late-breaking Netra CP3250 Blade Server Product 820-5194
PDF,
Online
Information
Notes
HTML
Safety
Information
Netra CP3250 Blade Server Safety
and Compliance Guide
820-5198
816-7190
PDF,
HTML
Online
Shipkit
Safety
Information
Important Safety Information for
Sun Hardware Systems
Printed
The following table lists the documentation that is related to this product.
.
Application
Title
Part Number
Format
Location
Installation and Sun Netra CP32x0 SAS Storage
820-3147
PDF,
Online
Configuration
Advanced Rear Transition Module,
Dual HD User’s Guide
HTML
Installation and Sun Netra™ CP32x0 Quad GbE,
820-3148
PDF,
Online
Configuration
Dual Fibre Channel, Advanced Rear
Transition Module, User’s Guide
HTML
Installation and Sun Netra™ CP32x0 10GbE
820-3150
PDF,
Online
Configuration
Advanced Rear Transition Module,
Dual Port User’s Guide
HTML
Documentation, Support, and Training
Sun Function
Documentation
Support
URL
Training
xvi
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
Third-Party Web Sites
Sun is not responsible for the availability of third-party web sites mentioned in this
document. Sun does not endorse and is not responsible or liable for any content,
advertising, products, or other materials that are available on or through such sites
or resources. Sun will not be responsible or liable for any actual or alleged damage
or loss caused by or in connection with the use of or reliance on any such content,
goods, or services that are available on or through such sites or resources.
Sun Welcomes Your Comments
Sun is interested in improving its documentation and welcomes your comments and
suggestions. You can submit your comments by going to:
Please include the title and part number of your document with your feedback:
Sun Netra CP3250 Blade Server User’s Guide, part number 820-5195.
Preface
xvii
Download from Www.Somanuals.com. All Manuals Search And Download.
xviii Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER
1
Overview
This chapter provides an overview of the features, configurations, and system
This chapter contains the following sections:
■
■
■
■
■
■
■
Section 1.1, “Overview” on page 1-2
Section 1.2, “Features” on page 1-2
Section 1.3, “Physical Description” on page 1-4
Section 1.4, “System Configurations” on page 1-7
Section 1.5, “Hot-Swap Support” on page 1-11
Section 1.6, “System Components” on page 1-11
Section 1.7, “Technical Support and Warranty” on page 1-13
1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
1.1
Overview
The Sun Netra CP3250 blade server is a dual-socket quad-core Intel-based ATCA
blade for high performance ATCA x86 applications in wireless infrastructure and
central office consolidation.
This blade server complies with the AdvancedTCA specification and is a new
addition to SUN's ATCA product family.
The ATCA standard comprises the PICMG 3.0, 3.1, 3.2, and 3.3 versions of the
standard. The Sun Netra CP3250 blade server complies with the following
specifications:
■
PICMG 3.0, the base specification that defines the mechanical, power distribution,
system management, data transport, and regulatory guidelines.
■
PICMG 3.1, which builds on the PICMG 3.0 base specification and on IEEE
802.3-2003.
1.2
Features
The blade server’s primary features are as follows:
■
ATCA card 322.25 mm x280 mm, 1.2 inch slot height
■
Two Harpertown Processor Sockets, QuadCore version @2.135 GHz and up to
40W per CPU
■
■
Intel San Clemente North Bridge and Intel ICH9R I/O controller hub
DDR2 (registered, with ECC) at 667 MHz, up to six modules/cards, up to 4 GB
per DIMM, in very-low-profile design (0.72 inch height)
■
■
■
■
Two 1000MBASE-T Ethernet base fabric (PICMG 3.0) interface ports (using
BCM5715C) from PCIe x4
Two 10 Gb XAUI Ethernet extended fabric (PICMG 3.1) interface ports (using Sun
Neptune) from PCIe x8
One AMC.1 Type 8S2E2 expansion slot (PCIe x8) supporting I/O expansion with
signaling to the advanced rear transition module (ARTM)
One Asynchronous serial port routed to front panel and ARTM from SuperIO
1-2
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
■
■
Dual USB 2.0/1.1 ports on front panel
One 10/100/1000MHBASE-T management port on front panel, with second
management LAN sent to ARTM (from BCM 5715C); these are not directly tied
into IPM controller.
■
SATA to EIDE master to support one Compact Flash Type II socket up to 16 GB of
user Flash. Socket is only accessible when blade is removed from chassis
■
■
Redundant BIOS, 8MB
Management support using on-board IPM controller (Renesas H8) that provides
dual IPMB bus. The IPMB bus is to be monitored by the shelf manager, providing
redundant IPMI channels
■
Rear I/O expansion/connectivity provided to an optional ARTM. Compatible
with Sun’s current ARTM architecture with upgrade capability to support PICMG
working group ARTM.0 standard (Zone 3 Interface)
■
■
■
SAS connectivity from ARTM to AMC slot
Contains TPM (Trusted Platform module) chip
225W delivered max power for the complete card (including 25W ARTM) via
dual, redundant -48 VDC nominal rails
■
Certified NEBS compliant in Sun’s Netra CT 900 system
Chapter 1 Overview
1-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure Legend
1
2
3
4
5
6
7
8
9
Locking screws
Latches
Out-of-service (OOS) LED
OK LED
AMC slot
10/100/1000 Ethernet management port
Serial port
USB port
Reset button
Chapter 1 Overview
1-5
Download from Www.Somanuals.com. All Manuals Search And Download.
1.3.2
Blade Server Diagram
FIGURE 1-2 Netra CP3250 Blade Server (Component Side View)
Figure Legend
1
2
3
CF card slot
4
5
6
Zone 1 power connector
DIMMs
Zone 3 connectors
Zone 2 connectors
CPU heatsinks
1-6
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
1.4
System Configurations
Sun Netra CP3250 blade servers can be installed into an ATCA shelf (chassis), as
shown in FIGURE 1-3. The blade servers can be deployed in various electrical
configurations to suit user requirements. For example, the blade server can be
configured to boot from a network as a diskless client with either a front panel or
ARTM network connection. The Sun Netra CP3250 blade server has an optional
Compact Flash card and connectors for additional memory.
FIGURE 1-3 Netra CP3250 Blade Server in Shelf Enclosure
Chapter 1 Overview
1-7
Download from Www.Somanuals.com. All Manuals Search And Download.
1.4.1
1.4.2
AMC
The Sun Netra CP3250 blade server has one AMC slot, with eight lanes of PCIe, to
provide additional I/O to the front panels or to the rear of the enclosure when used
with an ARTM.
The Sun Netra CP3250 blade server supports AMC mid-height, single wide cards, as
defined by the AMC specification.
Advanced Rear Transition Module
You can install one of the optional Netra CP32x0 advanced rear transition modules
server.
For more information, refer to the following documentation: Sun Netra CP32x0 SAS
Storage Advanced Rear Transition Module, Dual HD User’s Guide (820-3147)
(ARTM-HD)
FIGURE 1-4 shows the physical relationship between the Sun Netra CP3250 blade
server, the ARTM, and the backplane in a typical ATCA system.
1-8
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
You can order a Netra CP32x0 ARTM, build a custom module, or buy one from an
IHV. You must set up a minimal set of I/O for a boot path for the host blade server
and for a path for console I/O to deliver commands and read blade server and
system status.
Possible boot and console configurations are described in TABLE 1-1. Sun
Microsystems provides the Sun Netra CP3250 blade server and, optionally, a
compatible Netra CP32x0 ARTM. The ARTM provides one 10/100/1000BASE-T per
second Ethernet RJ-45 port from the host to the rear of the system. This port can be
used to accomplish, optionally, a network boot as a diskless client. The other
configurations require IHV hardware.
TABLE 1-1
I/O Configurations
I/O
Hardware Required
Description
Ethernet
Netra CP32x0 ARTM, as an
option for rear access
The default boot path uses an Ethernet port; the blade server
runs in a diskless client configuration
SAS
Netra 146-GB hard disk and the Available with the optional Netra CP32x0 ARTM-HD or
Netra CP32x0 ARTM-HD
through an AMC with SAS capabilities. When the optional
ARTM is installed, connect to the drive(s) via SAS ports on the
ARTM.
Zone 3
ARTM
ARTM
Zone 3
Serial data
Sun Netra CP3250 blade server Serial port A on the front panel provides the path of the default
console I/O.
When an optional Netra CP32x0 ARTM is installed, the
module’s serial port A will become the path of the default
console I/O (FIGURE 1-4).
Serial data
Netra CP32x0 ARTM
Compact
Flash
IDE Compact Flash card
Sun Netra CP3250 blade server supports one, optional IDE
Compact Flash drive, either 8-Gbyte or 16-Gbyte, installed in a
Type II CF socket on the blade server.
1-10
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
1.5
Hot-Swap Support
Hot-swap support for inserting and extracting blade servers is provided in
accordance with the ATCA PICMG 3.0 and 3.1 standards.
Hot-swap of the CP3250, ARTM, and AMC is supported in the Netra CT 900 server.
1.6
System Components
This section contains the system-level hardware and software components, required
and optional, for the Sun Netra CP3250 blade server.
1.6.1
Required Hardware Components
The Sun Netra CP3250 blade server cannot be used as a stand-alone system. It is
designed to be used in an ATCA chassis for 8U boards. The minimum hardware
requirements needed to use the Sun Netra CP3250 blade server are:
■
ATCA system enclosure for 8U boards (includes shelf, backplane, hub/switch
board, shelf manager and power supply)
■
■
■
■
■
■
Console output device or serial terminal
Boot device (such as hard drive, network, or Compact Flash card)
Peripheral device for network access
IPMC (built in)
Cables for terminal and network connections
Netra CT 900 server fan tray upgrade kit (PN 594-4953-01). If you are installing
the Sun Netra CP3250 blade server in a Netra CT 900 server that has lower-speed
fan trays, you must upgrade the Netra CT 900 server fan trays to support the
additional cooling needs of the Sun Netra CP3250 blade server. For more
information on the Netra CT 900 server fan tray upgrade kit (PN 594-4953-01), see
the Netra CT 900 Server Upgrade Guide (820-3255).
Caution – You can damage the Sun Netra CP3250 blade server components if you
install the blade server in a chassis that does not provide sufficient cooling. For more
information, see Section 2.2.1.1, “Check Power, Thermal, Environmental, and Space
Requirements” on page 2-4.
Chapter 1 Overview 1-11
Download from Www.Somanuals.com. All Manuals Search And Download.
Note – Use only serial cables that are less than 10 meters in length.
1.6.2
Optional Hardware Components
Sun Microsystems provides the following items for customer order:
■
■
■
Compact Flash card
AMCs
Netra CP32x0 ARTM (optional)
The ARTM is optional and must be ordered separately from the Sun Netra
CP3250 blade server.
The optional ARTM enables rear system I/O access to the following:
■
■
■
■
Network
Boot device
Two hot-swappable SAS hard disk drives (optional)
Console terminal (FIGURE 1-3).
■
Sun Netra CP3240 switch (optional)
The Sun Netra CP3240 switch is capable of operating at 10 GbE, but is set by
default to operate at 1GbE. To use the switch at 10 GbE, perform a one-time
configuration procedure, available in the Sun Netra CP3x40 Switch Product Notes
(820-3260).
1.6.3
Software Components
The following OSs are certified for use on Sun Netra CP3250 blade server:
■
■
■
■
Solaris™ 10 (05/08) Operating System (Solaris OS)
WindRiver Linux 3.1
RedHat Linux 5.2
Windows 2003
Additional OSs are being tested and will be supported after they are certified.
Refer to the Netra CP3250 Blade Server Product Notes (820-5194) for more Solaris OS
information, including a list of any required Netra software patches and support for
subsequent versions of Solaris and other OSs. You can view and download the latest
version of the product notes at the following web site:
1-12
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
Additionally, VMware is a software component certified to work with the Sun Netra
CP3250 blade server. It is listed on VMware’s HCL at:
http://www.vmware.com/resources/compatibility/search.php?action=
search&deviceCategory=server&productId=1&keyBasic=
-1&stepping=&nsockets=&ncores=&max_mem=
1.7
Technical Support and Warranty
Should you have any technical questions or support issues that are not addressed in
the Sun Netra CP3250 blade server documentation set or on the technical support
web site, contact your local Sun Services representative. This hardware carries a
one-year return-to-depot warranty.
For customers in the U.S. or Canada, call 1-800-USA-4SUN (1-800-872-4786).
For customers in the rest of the world, please find the World Wide Solution Center
nearest you at the following web site:
When you call Sun Services, be sure to indicate if the Sun Netra CP3250 blade server
was purchased separately, and is not associated with a system. Please have the blade
server identification information ready. For proper identification of the blade server,
be prepared to give the representative the blade server part number, and serial
number.
1.7.1
Information
The Sun Netra CP3250 blade server part number, serial number, revision number,
and media access control (MAC) address are printed on stickers located on the Sun
Netra CP3250 blade server (FIGURE 1-5).
The Sun barcode label provides the following information:
■
Blade server serial number (for example, 1005LCB-07296R0912), which is on the
barcode label
The part number/dash/revision/date code label provides the following
information:
Chapter 1 Overview 1-13
Download from Www.Somanuals.com. All Manuals Search And Download.
■
Blade server part number (for example, 3753529), which is the first seven digits on
the part number label
■
■
Product dash number (for example, -01)
Revision number (for example, REV: 01)
The MAC address label contains the base MAC address for the blade server in
printed and barcode form. It is an orange label located on the Zone 1 connector.
FIGURE 1-5 Netra CP3250 Blade Server Barcode Labeling
Part number label
Serial number label
1.7.2
Viewing the Electronic Blade Server ID
Information
The Sun Netra CP3250 blade server can be electronically identified through its IPMI
FRU ID PROM, which is accessible through standard fruutilities.
The IPMI FRU ID PROM format follows the Intel Specification IPMI Platform
Management FRU Information Storage Definition, v1.0 Document, Revision 1.1,
September 27, 1999.
1-14
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
The IPMI FRU ID manufacturing records match Sun part number and serial number
labels on the product. For more information about part number and serial number
labels, see Section 1.7.1, “Locating the Part Number and Serial Number Information”
on page 1-13.
The IPMI FRU ID contains six FRU ID areas, which are defined in TABLE 1-2.
TABLE 1-2
FRU Area
FRU ID Areas
Description
COMMON
HEADER
Contains header and pointers to other FRUID sections and is used
by fruutility software
INTERNAL USE
AREA
Not present
CHASSIS INFO
AREA
Not present
BOARD INFO
AREA
Contains the manufacturing record without memory (FRU part
number) for the FRU level assembly of the blade server. This
assembly level is equivalent to the FRU replacement that is received
from Sun Service.
• Mfg Date/Time = (Date/Time of blade server assembly}
• Manufacturer = {manufacturer name)
• Product Name = CP3250
• Serial Number = XXXXXXX-XXXXXXXXXX (Sun 18-digit format)
• Part Number = 000000000PPPPPPPDDRR (Sun Part Number)
where 0 = Leading zeroes, P= Part Number, D=Dash, R=Rev
PRODUCT INFO
AREA
Contains manufacturing record for configured blade server with
memory. This assembly level includes the base blade server (FRU)
plus memory.
• Manufacturer = (manufacturer name)
• Product Name = CP3250
• Part/Model Number = 000000000PPPPPPPDDRR (Sun Part
Number) where 0 = Leading zeroes, P= Part Number, D=Dash, R=
Rev
• Product Version = XXXX (dash/rev)
• Serial Number = XXXXXXX-XXXXXXXXXX (Sun 18-digit format)
MULTIRECORD
INFO AREA
Sun Internal Use Only
Chapter 1 Overview 1-15
Download from Www.Somanuals.com. All Manuals Search And Download.
1-16
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER
2
Hardware Installation and Service
This chapter describes the Sun Netra CP3250 blade server hardware installation and
service procedures.
This chapter contains the following sections:
■
■
■
Section 2.1, “Safety and Tool Requirements” on page 2-2
Section 2.2, “Installing the Blade Server” on page 2-4
Section 2.3, “Service Procedures” on page 2-17
2-1
Download from Www.Somanuals.com. All Manuals Search And Download.
2.1
Safety and Tool Requirements
2.1.1
Equipment and Operator Safety
Refer to the Important Safety Information for Sun Hardware Systems (816-7190) for
general safety information and to the Netra CP3250 Blade Server Safety and Compliance
Guide (820-5198) for specific safety information.
Read the following safety statements that are specific to the Sun Netra CP3250 blade
server carefully before you install or remove any part of the system.
Caution – Depending on the particular chassis design, operations with open
equipment enclosures can expose the installer to hazardous voltages with a
consequent danger of electric shock. Ensure that line power to the equipment is
disconnected during operations that make high voltage conductors accessible.
The installer must be familiar with commonly accepted procedures for integrating
electronic systems and the general practice of Sun systems integration and
administration. Although parts of these systems are designed for hot-swap
operation, other components must not be subjected to such stresses. Work with
power connected to a shelf only when necessary, and follow these installation
procedures to avoid equipment damage.
This equipment is sensitive to damage from electrostatic discharge (ESD) from
clothing and other materials. Use the following antistatic measures during an
installation:
■
If possible, disconnect line power from the shelf when servicing a system or
installing a hardware upgrade. If the shelf cannot be placed on a grounded
antistatic mat, connect a grounding strap between the facility electrical input
ground (usually connected to the shelf) and facility electrical service ground.
■
Use an antistatic wrist strap when performing the following tasks:
■
Removing a blade server from its antistatic bag
■
Connecting or disconnecting blade servers or peripherals
2-2
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
The other end of the antistatic wrist strap lead should be connected to one of the
following:
■
A ground mat
■
The chassis metal as a ground
The grounded mat or the chassis must be connected to a facility ground to
prevent a floating ground.
■
■
Keep blade servers in the antistatic bags until they are needed.
Remove a blade server from its antistatic bag only when wearing a properly
connected ground strap.
■
Place circuit blade servers that are out of their antistatic bags on an antistatic mat
if one is available and the mat is grounded to a facility electrical service ground.
Do not place blade servers on top of an antistatic bag unless the outside of the bag
also has antistatic protective properties.
2.1.2
Materials and Tools Required
The tools required for installation and service are as follows:
■
■
■
■
Phillips screwdrivers: No. 1 (required), No. 2 (optional)
Antistatic wrist strap
Terminal console
Serial cable of less than 10 meters in length to connect the Sun Netra CP3250
blade server with a system console
Refer to Section 1.6, “System Components” on page 1-11 for information on
hardware requirements.
Chapter 2 Hardware Installation and Service
2-3
Download from Www.Somanuals.com. All Manuals Search And Download.
2.2
Installing the Blade Server
2.2.1
Prepare for installation by reading and performing the following steps.
2. Verify that all listed hardware and software are available (see Section 1.6, “System
Section 2.2.1.1, “Check Power, Thermal, Environmental, and Space Requirements”
on page 2-4).
4. Verify that local area network (LAN) preparations are completed (see
Section 2.2.1.2, “Local Network IP Addresses and Host Names Worksheet” on
page 2-5).
5. Ensure that the host names and their network IP addresses are allocated and
registered at the site. Record this information in TABLE 2-1.
2.2.1.1
Requirements
Observe that your environment meets the following requirements:
■
Your enclosure specifications can support the sum of the specified maximum
blade server power loads. (See Section B.2, “Power and Thermal Metrics” on
page B-2).
■
■
Facility power loading specifications can support the rack or enclosure
requirements.
Your enclosure specifications can support the cooling airflow requirements.
The Sun Netra CP3250 blade server fits into a standard ATCA shelf. If your
installation requirements are different, contact your field applications engineer.
2-4
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
2.2.1.2
Local Network IP Addresses and Host Names Worksheet
Collect the information listed in TABLE 2-1 to connect hosts to the LAN. Ask your
network administrator for help, if necessary. This information is not needed for a
stand-alone installation.
TABLE 2-1
Local Area Network Information
Information Needed
Your Information
*
IP address and host name for each Sun
Netra CP3250 blade server client
Domain name
Type of name service and corresponding
name server names and IP addresses—for
example DNS and NIS (or NIS+)
Subnet mask
Gateway router IP address
Network File System (NFS) server names
and IP addresses
Web server URL
*
You might need the MAC (Ethernet) addresses of the local hosts to make name
server database entries. You can see the MAC address in the console output while
booting the blade server. You can also find it on the barcode label on the node blade
server (see Section 1.7.1, “Locating the Part Number and Serial Number
Information” on page 1-13).
Chapter 2 Hardware Installation and Service
Download from Www.Somanuals.com. All Manuals Search And Download.
2-5
2.2.1.3
Installation Procedure Summary
This section summarizes the high-level procedures that are required to install the
Sun Netra CP3250 blade server. Ensure that you are familiar with the information in
Section 2.2.2, “Configuring the Hardware” on page 2-6 through the end of Chapter 2
before installing the blade server.
The process to set up and configure a Sun Netra CP3250 blade server in a system
includes the following procedures:
For example, install the AMC and set switches, as necessary (Section 2.2.2,
Server in an ATCA Shelf” on page 2-8).
4. Connecting the nodes to a local network. (Section 2.2.4, “Connecting External I/O
Cables” on page 2-13).
5. Downloading and installing SunVTS (Section 4.1, “Operating Systems” on
page 4-2), if you are running the Solaris Operating System on the Sun Netra
CP3250 blade server and want to verify system integrity.
2.2.2
Configuring the Hardware
This section lists hardware installation and settings that might apply to your blade
server configuration. Read and perform the procedures, as necessary, before
installing the Sun Netra CP3250 blade server into the ATCA shelf.
2.2.2.1
Verify Chassis Fan Tray Upgrade
Caution – The Netra CT 900 server fan tray upgrade kit (594-4953) must be
installed in the chassis before the Sun Netra CP3250 blade server is installed. This
fan tray upgrade is required to provide adequate cooling and prevent the system
from overheating or shutting down due to an over temperature condition that can
occur with the older or mismatched fan trays.
2-6
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
●
To verify if the fan tray upgrade is installed on a Netra CT 900 server, log into
the Shelf Manager and issue the following command for fan trays 1,2, and 3:
# clia fruinfo fan_tray 1 | grep "Product Part"
If the “Product Part/Model Number” is 370-7764-xx, the fan trays must be replaced
with high-speed fan trays. Refer to the Netra CT 900 Server Upgrade Guide (820-3255)
for more information.
If the “Product Part/Model Number” is 371-3033-xx or newer, an upgraded fan tray
is already installed.
2.2.2.2
2.2.2.3
Installing Optional Components
DIMMs
“DIMM Requirements” on page 2-19
“Installing a DDR2 DIMM” on page 2-21
Compact Flash card “Installing the Optional Compact Flash Card” on page 2-24
AMC “Compact Flash Location” on page 2-26
If you are using one of the Netra advanced rear transition modules (ARTMs), refer to
the documentation: Netra CP32x0 SAS Storage Advanced Rear Transition Module, Dual
HD User’s Guide (820-3147) (ARTM-HD)
See Section B.3, “Connectors and Pinouts” on page B-2 for detailed connector pin
assignments for the Sun Netra CP3250 blade server.
Chapter 2 Hardware Installation and Service
Download from Www.Somanuals.com. All Manuals Search And Download.
2-7
2.2.3
Installing the Netra CP3250 Blade Server in an
ATCA Shelf
If you install the Sun Netra CP3250 blade server with an ARTM, the ARTM must be
installed first.
Note – Slots 1 through 6 and 9 through 14 are available for Sun Netra CP3250 blade
servers. Slots 7 and 8 are reserved for the switch card.
2.2.3.1
A compatible ARTM must be used with the Sun Netra CP3250 blade server for rear
terminal. You can use one of the Netra CP32x0 ARTMs or you can design your own
ARTM-compatible transition module. For more information, see Section 1.4.2,
“Advanced Rear Transition Module” on page 1-8.
1. Verify that you have taken the necessary antistatic precautions.
See Section 2.1.1, “Equipment and Operator Safety” on page 2-2.
The rear transition module must be installed, inline, behind a compatible Netra
blade server.
For example, if the Sun Netra CP3250 blade server will be installed in slot 3, the
corresponding rear transition module must be installed at the back of the system
in slot 3 (FIGURE 2-1). If you do not install the rear transition module and the Sun
Netra CP3250 blade server in corresponding slots, the system will recognize the
Sun Netra CP3250 blade server and not the rear transition module.
Note – Slots 1 through 6 and 9 through 14 are available for Sun Netra CP3250 blade
servers. Slots 7 and 8 are reserved for the switch card.
2-8
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
FIGURE 2-1 Installing a Netra CP32x0 ARTM
3. Remove the slot filler panel from the selected slot, if necessary.
4. Retrieve the advanced rear transition module (ARTM) from the ship kit.
5. Prepare the rear transition module by opening the injector/ejector latch at the
top of the module (FIGURE 2-2).
Chapter 2 Hardware Installation and Service
Download from Www.Somanuals.com. All Manuals Search And Download.
2-9
FIGURE 2-2 Injector/Ejector Latch and Locking Screw on the ARTM
6. Carefully align the edges of the ARTM with the card guides in the appropriate
slot.
Look into the enclosure to verify correct alignment of the rails in the guides.
7. Keep the ARTM aligned in the guides, and slide the module in until the
injector/ejector latches engage the card cage.
8. Push the ARTM into the backplane connectors, and close the latch.
9. Tighten the locking screws to ensure that the module is secured into the ATCA
shelf.
2-10
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
10. Install the Sun Netra CP3250 blade server into the front of the ATCA shelf in
the corresponding slot.
See Section 2.2.3.2, “Installing the Blade Server Into the Shelf” on page 2-11 for
instructions.
2.2.3.2
Installing the Blade Server Into the Shelf
Note – You can install the Sun Netra CP3250 blade server in any available slot in the
ATCA shelf except for slots 7 and 8.
1. If you have installed an advanced rear transition module (ARTM), go to the
front of the system and locate the corresponding slot number of the ARTM.
2. Remove the filler panel from the blade server slot, if necessary.
The filler panel is secured to the card cage using two screws, one at the top of the
filler panel, the other at the bottom. Store the filler panel in a safe place; you
might need to use it again if you remove a blade server for an extended time.
3. Prepare the Sun Netra CP3250 blade server by opening the injector/ejector
latches.
4. Carefully align the edges of the blade server with the guides in the appropriate
slot.
Look into the enclosure to verify correct alignment of the rails in the guides.
5. Keep the blade server aligned in the guides and slide the blade server in until
the injector/ejector latches engage the card cage.
6. Push the blade server slightly into the backplane connectors and close the
latches to seat the blade server in the connectors (FIGURE 2-3).
Push the upper latch lever to engage the blade server. When the upper and lower
levers are engaged properly, the blue Hot-Swap LED blinks while the blade server
is initializing. The blue LED turns off and the green OK LED lights when the
blade server is ready for use.
Note – If the hot-swap LED does not light, then wiggle and push the latch so it
engages the hot-swap switch.
Chapter 2 Hardware Installation and Service 2-11
Download from Www.Somanuals.com. All Manuals Search And Download.
FIGURE 2-3 Engaging the Netra CP3250 Blade Server Latch
7. Tighten the locking screws and the top and the bottom of the Sun Netra CP3250
blade server to ensure that it is secured to the ATCA shelf (FIGURE 2-2).
The blade server is now completely installed and will power on automatically.
8. Configure the switches accordingly as described in Section 4.4, “Configuring
Sun Netra CP3250 blade server For 1 GbE or 10 GbE Switches” on page 4-4.
2-12
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
2.2.4
Connecting External I/O Cables
Front panel ports are typically used for maintenance and troubleshooting purposes
in installed and running systems. External I/O cables are connected to the Sun Netra
CP3250 blade server or to the Netra CP32x0 rear transition module when a rear
transition module is used.
To connect each of these following cables:
■
For Ethernet connections, Category 5e or better, network cable is required.
Connect one end of the Ethernet cable to a suitable 10/100/1000 MBASE-T
Ethernet switch and the other end to one of the Ethernet ports on the Sun Netra
CP3250 blade server or the Netra CP32x0 ARTM.
■
Attach asynchronous serial I/O cables from serial communication devices to the
RJ-45 serial ports on the Sun Netra CP3250 blade server or Netra CP32x0 ARTM.
2.2.4.1
Connecting Cables to a System Console Running the Solaris
OS
1. Connect a RJ-45 style serial cable to the serial console port on the front panel of
the Sun Netra CP3250 blade server (FIGURE 2-4) or the Netra CP32x0 rear
transition module.
Serial access (both front and rear) is through the same serial interface controller. If
both ports are connected at the same time, console input and output can be
performed through both, however, this configuration is not recommended. If both
access interfaces are not connected at the same time, console input/output can be
performed through NetConsole session via the ShMM.
2. Connect the other end of the serial cable to the serial port of the system serving
as the serial console.
Chapter 2 Hardware Installation and Service 2-13
Download from Www.Somanuals.com. All Manuals Search And Download.
FIGURE 2-4 Serial Port on the Netra CP3250 Blade Server
Serial port
3. Use one of the following to establish a full-duplex serial terminal connection
with the Sun Netra CP3250 blade server:
■
The tiputility
■
The minicomutility
2-14
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
■
■
A telnetutility (Connect to the proper port on a Network Terminal Server to
which the Sun Netra CP3250 blade server is connected.)
Another suitable serial communications program on the system console
For example, if you are using a UNIX system as the system console, at the UNIX
prompt in a command tool or shell tool, or serial port A, type:
# tip -9600 /dev/ttya
2.2.4.2
Connecting Cables to the System Console Not Running the
Solaris OS
1. Connect a serial cable to the serial console port on the front panel of the Sun
Netra CP3250 blade server (FIGURE 2-4) or the Netra CP32x0 rear transition
module.
2. Connect the other end of the serial cable to the serial port of the system serving
as the system console.
and no handshake.
2.2.4.3
Netinstall Boot Device Map
TABLE 2-2 provides a map of netinstall boot devices. You may need this information
to understand which MAC address is associated with the system IP address on the install
server.
For example, the Base Fabric interface is connected to the switch model-number in
slot 8 of the ATCA shelf. To install to this device, select the xxx Ethernet interface
from the BIOS setup menus.
TABLE 2-2
Netinstall Boot Device Table
MAC Address
Solaris
Device
Hardware
Device
Switch Slot
Connection
Connects to...
00:14:4f:xx.yy.zz+0 bge0
00:14:4f:xx.yy.zz+1 bge1
00:14:4f:xx.yy.zz+2 bge2
(BMC5715C)
(BMC5715C)
Base Fabric 0
Slot 7
Slot 8
Base Fabric 1
(MCP55)and
(BCM5715C)
mgtA (front panel)
00:14:4f:xx.yy.zz+3 bge3
(MCP55)and
(BCM5715C)
mgtB (rear panel)
Chapter 2 Hardware Installation and Service 2-15
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE 2-2
Netinstall Boot Device Table (Continued)
MAC Address
Solaris
Device
Hardware
Device
Switch Slot
Connection
Connects to...
00:14:4f:xx.yy.zz+4 nxge0
(Sun 10 GbE
Extended Fabric 0
Slot 7
Multithreaded
Networking
Technolgy 10 GB)
0:14:4f.xx.xn+5
0:14:4f.xx.xn+6
0:14:4f.xx.xn+7
nxge1
nxge2
nxge3
(Sun 10 GbE
Multithreaded
Networking
Extended Fabric 1
AMC and ARTM
AMC and ARTM
Slot 8
Technolgy 10 GB)
(Sun 10 GbE
Multithreaded
Networking
Technolgy 1 GB)
(Sun 10 GbE
Multithreaded
Technolgy 1 GB)
The Sun Netra CP3250 blade server supports virtual LAN configuration for the Sun
10 GbE Multithreaded Networking Technolgy ports (MAC addresses 4, 5, 6, and 7).
When configured, the virtual LAN feature enables the assignment of multiple MAC
address to one port. TABLE 2-3 lists the extra MAC addresses available for the Sun 10
GbE Multithreaded Networking Technolgy ports.
TABLE 2-3
Extra MAC Addresses for Virtual LAN Configuration
Primary MAC Address
0:14:4f.xx.xn+4
0:14:4f.xx.xn+5
0:14:4f.xx.xn+6
0:14:4f.xx.xn+7
Additional MAC Addresses
0:14:4f.xx.xn+8 through 0:14:4f.xx.xn+14
0:14:4f.xx.xn+15 through 0:14:4f.xx.xn+21
0:14:4f.xx.xn+22 through 0:14:4f.xx.xn+28
0:14:4f.xx.xn+29 through 0:14:4f.xx.xn+35
2-16
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
2.3
Service Procedures
2.3.1
You can remove the Sun Netra CP3250 blade server without powering off the entire
chassis by performing these steps.
1. Power off the blade server.
See Section 2.3.2, “Powering Off the Netra CP3250 Blade Server” on page 2-17.
2. Remove the blade server.
See Section 2.3.3, “Removing the Netra CP3250 Blade Server” on page 2-18.
2.3.2
Powering Off the Netra CP3250 Blade Server
1. Shut down the operating system.
Log in and shut down any OS operating on the blade server or its companion
ARTM.
2. Deactivate the blade server.
Log in to the shelf manager and deactivate the blade server in the target slot.
For example, to shut down the blade server in slot 3, log in to the shelf manager
and type:
# clia deactivate board 3
Wait for the blue Hot-Swap LED to light steadily before removing the blade
server.
Chapter 2 Hardware Installation and Service 2-17
Download from Www.Somanuals.com. All Manuals Search And Download.
2.3.3
Removing the Netra CP3250 Blade Server
1. Power off the Sun Netra CP3250 blade server.
Use the instructions in Section 2.3.2, “Powering Off the Netra CP3250 Blade
Server” on page 2-17.
2. If installed, remove all cables from the front of the Sun Netra CP3250 blade
server.
3. Loosen the locking screws to release the blade server from the ATCA shelf.
4. When the blue Hot-Swap LED lights steadily, release the upper latch and the
lower latch at the same time to unseat the blade server from the connectors.
5. Remove the blade server from the ATCA shelf and place the blade server on an
antistatic mat.
2.3.4
2.3.5
Powering On the System
Sun Netra CP3250 blade servers are powered on automatically via the H8 BMC
when you install the blade server into a slot in the ATCA shelf. Once installed, the
blade server sequences through power-on states until it is fully powered on.
Automatic Power-Off Events
A power-off sequence is initiated either by a request from the shelf manager or a
fault condition. The Sun Netra CP3250 blade server shuts down to standby power
mode when the following upper critical threshold conditions are met:
■
Detection of DC input (both -48V A and -48V B) drop for more than 5ms
Processor thermal trip drops to standby mode
■
Thermal trip of DC brick turns off all local power (standby included)
2-18
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
2.3.6
Servicing DIMMs
2.3.6.1
DIMM Requirements
The Sun Netra CP3250 blade server supports a total of six DIMMs and the maximum
memory capacity of 24 GB (using four 4 GB DIMMs). The Sun Netra CP3250 blade
server accommodates the following DIMMs and configurations:
■
■
■
■
Up to six standard DDR2 SDRAM registered/ECC DIMMs
DIMMs must be installed in matching pairs
2 GB and 4 GB DDR2 modules are supported
Maximum of 24 GB in six slots
The Sun Netra CP3250 blade server supports DIMMs that have the following
characteristics:
■
■
■
A 144-bit wide data bus DDR2 interface (2x64-bit data + 2x8-bit ECC)
DDR2 DIMM: 4.4 - 7.0 watts (1.8 V)
Very low profile (VLP) with a maximum height of 0.72 inch (18.3 mm)
Chapter 2 Hardware Installation and Service 2-19
Download from Www.Somanuals.com. All Manuals Search And Download.
FIGURE 2-5 Locating DIMM Slots
Populate DIMMs in matching pairs, starting with Pair 0, then adding Pair 1, then
Pair 2.
There are two channels, Channel A and Channel B. DIMMs are identified as A0, B0,
A1, B1, A2, and B2. Where Pair 0 would be A0 and B0, and so on.
2-20
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
2.3.6.2
Installing a DDR2 DIMM
However, for specific directions on installing DIMMs on the Sun Netra CP3250 blade
server, refer to the documentation that shipped with the DIMMs.
1. Access the blade server by performing one of the following procedures:
■
If the Sun Netra CP3250 blade server is installed in an ATCA shelf, remove the
blade server from the shelf as explained in Section 2.3.3, “Removing the Netra
CP3250 Blade Server” on page 2-18.
■
Remove the Sun Netra CP3250 blade server from its antistatic envelope and place
it on an ESD mat near the ATCA shelf.
Caution – Always wear a grounded antistatic wrist strap when handling DIMMs.
3. Locate the DIMM connectors on the Sun Netra CP3250 blade server.
Select the connectors where you will install the DIMM. See FIGURE 2-5 for DIMM
slot locations.
Caution – Do not remove the DIMM from its antistatic container until you are
ready to install the DIMM on the Sun Netra CP3250 blade server. Handle the DIMM
only by its edges. Do not touch DIMM components or metal parts. Always wear a
grounded antistatic wrist strap when handling DIMM.
4. Remove the DIMM from its protective packaging, holding the module only by
the edges.
Note – Before installing a replacement DIMM, verify that the new DIMM is the
same size as its paired DIMM.
5. Holding the DIMM upright to the blade server, insert the bottom edge of the
DIMM into the bottom of the slot’s hinge-style connector (FIGURE 2-6).
Caution – Evenly engage the DIMM in its hinge-style slot; uneven contact can
cause shorts that will damage the Sun Netra CP3250 blade server. Do not rock the
DIMM into place. Ensure that all contacts engage at the same time. You will feel or
hear a click when the DIMM properly seats in the connector.
Chapter 2 Hardware Installation and Service 2-21
Download from Www.Somanuals.com. All Manuals Search And Download.
The socket and module are both keyed, which means that the DIMM can be installed
only one way. With even pressure, push simultaneously on both upper corners of the
DIMM until its bottom edge (the edge with the gold fingers) is firmly seated in the
connector.
FIGURE 2-6 Installing a DIMM
6. Press the top edge of the DIMM toward the blade server until the retainer clips
click into place in the notches on the DIMM sides (FIGURE 2-6).
The small metal retainer clips on each side of the DIMM slot are spring-loaded, and
they should click into place in the notches on the sides of the DIMM.
2-22
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
2.3.6.3
Removing a DDR2 DIMM
If you are returning the DIMM or the blade server for service, or if you are replacing
a DIMM with another DIMM, remove the DIMM from the Sun Netra CP3250 blade
server.
Note – Safely store the original factory-shipped DIMM and related DIMM
packaging. Store any removed DIMM in the new DIMM packaging.
To remove a DIMM from the Sun Netra CP3250 blade server, perform the following
steps:
1. Access the blade server by performing one of the following procedures:
■
If the Sun Netra CP3250 blade server is installed in an ATCA shelf, remove the
blade server from the shelf as explained in Section 2.3.3, “Removing the Netra
CP3250 Blade Server” on page 2-18.
■
Remove the Sun Netra CP3250 blade server from its antistatic envelope and place
it on an ESD mat near the ATCA shelf.
If an ESD mat is not available, you can place the blade server on the antistatic
envelope in which it was packaged.
Caution – Do not place blade servers on top of an antistatic bag unless the outside
of the bag also has antistatic protective properties.
2. Take antistatic precautions: Attach and electrically ground the wrist strap.
Caution – Always wear a grounded antistatic wrist strap when handling DIMMs.
3. Simultaneously pull both spring retainer clips outward from the slot for the
DIMM you want to remove.
4. Grasp the DIMM by the edges, and carefully pull it out of its connector.
Place it in an antistatic bag.
Chapter 2 Hardware Installation and Service 2-23
Download from Www.Somanuals.com. All Manuals Search And Download.
FIGURE 2-7 Removing a DIMM
5. If you are replacing the DIMM you removed with a new DIMM, install it as
described in Section 2.3.6.2, “Installing a DDR2 DIMM” on page 2-21.
2.3.7
Installing the Optional Compact Flash Card
An IDE Compact Flash card can be installed on the Sun Netra CP3250 blade server.
The Compact Flash card is not hot-swappable, and there is no access to the Compact
Flash card once the Sun Netra CP3250 blade server is installed in an ATCA shelf.
1. Access the blade server by performing one of the following procedures:
■
If the Sun Netra CP3250 blade server is installed in an ATCA shelf, remove the
blade server from the shelf as explained in Section 2.3.3, “Removing the Netra
CP3250 Blade Server” on page 2-18.
■
Remove the Sun Netra CP3250 blade server from its antistatic envelope and place
it on an ESD mat near the ATCA shelf.
If an ESD mat is not available, you can place the blade server on the antistatic
envelope in which it was packaged.
Caution – Do not place blade servers on top of an antistatic bag unless the outside
of the bag also has antistatic protective properties.
2-24
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Push where indicated on door that provides access to the Compact Flash, then
open the door.
FIGURE 2-8 shows the door.
FIGURE 2-8 Opening the Door to Access Compact Flash
3. Locate the Compact Flash connector.
The connector is located on the blade server, behind the sheet metal door
protecting the AMC slot B1 (FIGURE 2-9).
Chapter 2 Hardware Installation and Service 2-25
Download from Www.Somanuals.com. All Manuals Search And Download.
FIGURE 2-9 Compact Flash Location
4. To install the Compact Flash card, use the arrow on the card as a guide to insert
the card into the Compact Flash connector.
Note – Sun Compact Flash cards have a life time of 2,000,000 write/erase cycles.
Users are responsible for ensuring that the operating system and applications do not
exceed this limitation.
2-26
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
2.3.8
Installing Optional AMC
An Advanced Mezzanine card (AMC) is a card or module that provides additional
functionality to the Sun Netra CP3250 blade server. The blade server contains one
AMC slot in which you can install an optional AMC device. An AMC device can be
installed and removed via a cutout in the front panel while the Sun Netra CP3250
blade server is installed in the chassis.
Note – The following procedure provides a general set of instructions for installing
an AMC on the Sun Netra CP3250 blade server. Refer to the AMC manufacturer’s
documentation for specific instructions on installing these devices.
1. Retrieve the wrist strap from the shipping kit.
chassis.
Wrap the other end twice around your wrist, with the adhesive side against your
skin.
3. Remove the AMC slot filler panel from the blade server’s front panel
(FIGURE 2-10).
Chapter 2 Hardware Installation and Service 2-27
Download from Www.Somanuals.com. All Manuals Search And Download.
FIGURE 2-10 Removing an AMC Filler Panel
4. Retrieve the AMC from its shipping kit and place it on an antistatic surface.
5. Insert the AMC through the cutout and into the AMC slot (FIGURE 2-11).
2-28
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
FIGURE 2-11 Installing an AMC
Caution – Do not use excessive force when installing the AMC into the slot. You
might damage the AMC connector on the Sun Netra CP3250 blade server, causing
permanent damage to the AMC or the blade server. If the AMC does not seat
properly when you apply even pressure, remove the AMC and carefully reinstall it.
Chapter 2 Hardware Installation and Service 2-29
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Carefully push the AMC into the AMC connector.
7. Refer to the AMC documentation for software and cabling installation
instructions.
2.3.9
Adding or Replacing the Battery
The Sun Netra CP3250 blade server does not ship with the battery. If you want
CMOS settings to be preserved in the event of power loss, obtain and install the
battery.
The battery must be type CR1632, with a minimum of 4ma abnormal charging
current rating (for example; a Renata CR1632).
Caution – Risk of explosion if the battery is replaced by an incorrect type. Dispose
of used batteries properly in accordance with manufacturer’s instructions and local
regulations.
To install the battery:
1. Remove the old battery, if necessary.
2. Slide the new battery into the holder with the side labeled “+” facing up.
2-30
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
2.3.10
Changing Jumper Settings
Jumpers and their switches are located near the heatsink on the blade server.
2.3.10.1
Clearing the CMOS Setting Using Jumper 2
Reset jumper 2 to clear the CMOS settings, which restores the default BIOS settings.
Jumper 2 is shown in FIGURE 2-12. The jumper housing should be stored in the P2/P3
position, which is the run position.
FIGURE 2-12 Jumper 2 in the Default Run Position
TABLE 2-4 provides information on the pin functions on jumper 2.
TABLE 2-4
Pin Functions on Jumper 2
Pin Number
Pin 1
Purpose
Battery Feed
Pin 2
VCC_RTC (destination for battery
power)
Pin 3
BATT_CLR (resistor to GND, used to
drain capacitive charge and clear the
CMOS memory)
Chapter 2 Hardware Installation and Service 2-31
Download from Www.Somanuals.com. All Manuals Search And Download.
the following steps:
1. Remove the jumper housing from the run position (P2/32) and move it to the
reset position (P1/P2).
2. Wait at least one second for the CMOS settings to reset and then move the
jumper housing back to the run position (FIGURE 2-12).
3. Reinstall the blade server.
Use the procedure in Section 2.2.3.2, “Installing the Blade Server Into the Shelf”
on page 2-11.
Note – The blade server will operate normally only when the jumper housing is in
the run position.
2.3.10.2
Changing the OOS LED Color Using Jumper 13
The color of the Out-of-service (OOS) LED can be set to red or amber by moving
jumper 13 to the appropriate position. Amber is the default color for the OOS LED.
1. Remove the jumper housing from the default (amber) position (P2/P3) and
move it to the red position (P1/P2).
2. Reinstall the blade server.
Use the procedure in Section 2.2.3.2, “Installing the Blade Server Into the Shelf” on
page 2-11.
2-32
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
2.3.11
Checking DIP Switch Settings
DIP switch settings are set by default at the factory. The following settings are
required for normal operation of the blade server.
FIGURE 2-13 SW1 Default DIP Switch Settings
FIGURE 2-14 SW4 Default DIP Switch Settings
Chapter 2 Hardware Installation and Service 2-33
Download from Www.Somanuals.com. All Manuals Search And Download.
FIGURE 2-15 SW5 Default DIP Switch Settings
2.3.12
Resetting the Netra CP3250 Blade Server
Caution – Do not operate the ATCA shelf without all fans, component heatsinks, air
baffles, and covers installed. Severe damage to components can occur if the ATCA
shelf is operated without adequate cooling mechanisms.
1. Use a spudger tool or other stylus to press and release the recessed Reset
button on the front of the Sun Netra CP3250 blade server (FIGURE 2-16).
2. Confirm the progress of the reset by monitoring the BIOS POST messages.
2-34
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
2-36
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER
3
Hardware Architecture
This chapter describes the hardware components and architecture of the Sun Netra
CP3250 blade server.
This chapter contains the following sections:
■
■
■
■
■
■
Section 3.1, “Block Diagram” on page 3-2
Section 3.2, “Intel Processors” on page 3-3
Section 3.3, “Intel San Clemente MCH” on page 3-3
Section 3.4, “Memory” on page 3-4
Section 3.5, “Networking and I/O” on page 3-5
Section 3.6, “I/O Components” on page 3-8
3-1
Download from Www.Somanuals.com. All Manuals Search And Download.
3.2
Intel Processors
The Sun Netra CP3250 blade server supports dual 64-bit low voltage Intel Xeon
(Harpertown) processors at 2.13 GHz with 12 MB of L2 cache and a 1066 MHz
system bus. This processor is designed for high-performance, low-power
communication, storage, and embedded applications. It is built on Intel’s new 65nm
topology. The following are the key features of the Harpertown processor:
■
Quad-Core processor optimized for high performance, low-power
communication, storage, and embedded applications.
■
■
Four complete execution cores in a single processor
Dual processor support (eight high-performance cores per Sun Netra CP3250
blade server)
■
■
■
■
■
■
■
■
FSB Parity Protection providing key reliability and data integrity features
Intel Smart Cache Technology
Enhanced 36-bit memory addressing
FSB address, data, and response parity protection
Enhanced Intel Speedstep Technology
Intel¨ Advanced Thermal Manager
Streaming SIMD Extensions 3 (SSE3) Support
Embedded life cycle support
3.3
Intel San Clemente MCH
The architecture of the Intel E7520 Memory Controller Hub (MCH) provides the
performance and feature set required for performance servers, with configuration
options that facilitate optimization of the platform for workloads characteristic of
communication, presentation, storage, performance computation, or database
applications. To accomplish this, the MCH has numerous Reliability, Availability,
Serviceability, Usability and Manageability (RASUM) features on multiple interfaces.
The following list provides key features on the MCH:
■
Supports two processors on dual independent point-to-point system buses
operating at 266MHz (1066MTS) or 333MHz (1333MTS)
■
Six PCI Express x4 ports. Each of these ports can be configured as x4, x8, or x16
ports interfaces
Chapter 3 Hardware Architecture
Download from Www.Somanuals.com. All Manuals Search And Download.
3-3
■
■
Enterprise South Bridge Interface (ESI) to ICH9 device
Maximum memory bandwidth using DDR2-667 is 10.6GB per slot for two DDR2
channels
3.4
Memory
The Sun Netra CP3250 blade server supports 4-Gbyte registered DDR2-667 memory,
for up to 24 Gbytes memory total. When four DIMM slots or less are populated, the
DIMM clock rate will be set to the max clock rate of up to 333 Mhz. When six
DIMMs slots are populated, the DIMM clock rate will be set to a max clock rate of
up to 267 Mhz.
For optimal performance, memory DIMMs must be installed in like pairs. The
controller supports 1 bit per byte ECC and supports DDR2 667 registered DRR
SDRAM modules. For more information on supported DIMM configurations, see
Section 2.3.6.1, “DIMM Requirements” on page 2-19.
Additional features of the Sun Netra CP3250 blade server’s memory architecture
include:
■
■
■
Very low profile (0.72 inch) DIMM support
Memory bandwidth up to 5.3 Gbyte/sec
DDR2 power requirements 4.4W to 7.0W (1.8V)
Although single channel operation is defined by the Intel Memory Controller and
will function, this configuration will not be qualified, tested, or supported on the
Sun Netra CP3250 blade server.
The supported configuration is dual channel, which follows the DIMM loading
order: Pair 0 (first) -> Pair 1 (second) -> Pair 2 (third).
DIMMs must be loaded by pairs in the order indicated. Install DIMMs in pairs of
like memory types.
3-4
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
3.5
Networking and I/O
Networking and I/O are provided by the following chips and interconnects:
■
■
■
■
■
■
■
ICH9 I/O controller hub
PCI Express Bus
LPC bus interface
Redundant BIOS
Trusted Platform Module
Broadcom 5715C Gbit Ethernet chip
Sun 10 GbE Multithreaded Networking Technolgy Dual 10-Gbit + Dual 1-Gbit
Ethernet chip
3.5.1
3.5.2
ICH9 I/O Controller Hub
The ICH9 I/O provides legacy function support similar to that of previous
ICH-family devices, but with extensions in Serial-ATA technology and 64-bit/66
MHz PCI-X support. The ICH9 I/O also includes integrated USB 2.0 and USB 1.0
support, an LPC interface, a system management interface, a power management
interface, PECI interface, integrated Gigabit Ethernet controllers (not used on Sun
Netra CP3250 blade server), and an integrated DMA controller.
PCI Express Bus
PCI Express 1.0 (PCIe) is a high-speed, point-to-point dual simplex chip
interconnect. It is the latest extension of the PCI bus. PCIe operates at 2.5 GHz and
supports land widths of x1, x2, x4, x8, x16, and x32. Additional features include:
■
■
■
■
Serial point-to-point interconnect between two devices
Each lane supports two differential signal pairs, one pair for each data direction
2.5-Gbyte/sec transfer rate
Scalable performance based on the number of lanes implemented per interconnect
Chapter 3 Hardware Architecture
Download from Www.Somanuals.com. All Manuals Search And Download.
3-5
3.5.3
LPC Bus Interface
The LPC bus is a multiplexed (command, address, and data) serialized 4-bit bus
with optional side band signals. It replaces the ISA/X-bus and reduces pin count
(approximately 40) over the ISA/X-bus.
LPC is designed to reduce the cost of traditional X-bus devices and meet the data
transfer rate of X-bus, exceeding those data rates where appropriated. It performs
the same cycle types as the X-bus: Memory, I/O, DMA and Bus Master. And, it
increases the memory space from 16 Mbytes on the X-bus to 4 GB to allow BIOS
sizes much greater than 1 Mbyte and other memory devices outside of the
traditional 16 MByte range.
The LPC is software transparent and does not require special drivers or
configuration for its interface. The motherboard BIOS configures all devices at boot
up. It has the ability to support a variable number of wait states, to have I/O and
memory cycles retried in SMM handler and to support wake-up and other power
state transitions. The design meets LPC 1.0 design guidelines.
The LPC bus provides system connectivity to the following devices:
■
■
■
■
Redundant BIOS
TPM
IPMC
RS-232 Serial Ports
3.5.4
Redundant BIOS
The Sun Netra CP3250 blade server provides redundant 1-Mbyte BIOS chips that
support redundant BIOS images for increased reliability.
The redundant Flash PROMs and SRAM devices are used by the BIOS. Each PROM
is an 8 MB flash device. The primary flash device (FWH0) contains the primary BIOS
image, factory default settings, and user configured settings. The primary BIOS chip
is automatically selected for update during a firmware upgrade.
The secondary flash device (FWH1) contains a backup copy, normally of the last
known good BIOS image, factory default settings, and last good user-configured
settings. The secondary BIOS chip retains the original BIOS image, and can be used
through manual configuration if the primary BIOS is corrupt.
In the event of a checksum or other failure during boot of the primary BIOS image,
the H8 switches the system over to the secondary device to allow system boot
recovery.
3-6
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
3.5.5
3.5.6
Trusted Platform Module (TPM)
The Sun Netra CP3250 blade server provides a Trusted Platform Module (TPM) chip,
which enables various security features, including hardware and software
authentication. This chip is reserved for future use on the Sun Netra CP3250 blade
server.
IPMC
The H8S/2166 IPMC provides the IPM controller function on the Sun Netra CP3250
blade server. The IPMC provides PICMG 3.0 board management functionality, and
interfaces to the payload through a serial interface.
The IPMC provides the following:
■
■
■
■
■
Dual buffered IPMB interfaces to connect to IPMB-0
Hot-swap latch input and LED control
Payload power control
Payload base and fabric interface e-keying control
Payload power and temperature monitoring
3.5.7
RS-232 Serial Ports
A Serial port is available on the front panel using an RJ-45 connector. This same port
is also wired through the Zone 3 connectors to provide a copy of this port on the
ARTM. This connector shares the SuperIO chip Port A with the H8-IPMI controller,
to allow console messages to be directed to the H8 when the external ports are not in
use. The blade server detects a valid RS232 connection to either the front or rear port
and will automatically disconnect the SuperIO port from the H8 and connect to the
external ports.
Note – The front and rear ports cannot be used at the same time because they share
the same wires.
Chapter 3 Hardware Architecture
Download from Www.Somanuals.com. All Manuals Search And Download.
3-7
3.5.8
3.5.9
Broadcom 5715C Gigabit Ethernet
The Broadcom 5715C Gigabit Ethernet chip used on the Sun Netra CP3250 blade
server provides two 10/100/1000 MBASE-T interfaces to the Zone 2 connectors. It
incorporates the media access control (MAC) and physical (PHY) layer functions for
the two LANs used as the ATCA base fabric.
Sun Dual 10-Gbit Ethernet/Quad 1-Gbit RGMII
Network Interface Chip
The Sun Netra CP3250 blade server is equipped with one Sun Dual 10-Gbit
Ethernet/Quad 1-Gbit RGMII Network Interface chip (Sun 10 GbE Multithreaded
Networking Technolgy) that is specifically designed to support multicore and
multithreaded processor with minimum CPU load while maximizing network I/O
thoughput.
Sun 10 GbE Multithreaded Networking Technolgy provides two 10-Gbit XAUI
Ethernet connections to the ATCA backplane extended fabric, where four lanes are
driven at 3.125 Gbyte/sec (if the ATCA switch supports 10-Gbit Ethernet) or a single
lane at 1.25 Gbyte/sec if the switch is a 1-Gbit Ethernet device.
Sun 10 GbE Multithreaded Networking Technolgy also provides two 1-Gb RGMII
Ethernet connections to the Broadcom BCM5482H chip, which converts to SERDES
and routes the SERDES signals through an 8 port switch and providing two 1 Gb
LANS to Zone 3-RTM and to each AMC slot.
3.6
I/O Components
3.6.1
AMC Slot
The Sun Netra CP3250 blade server contains one AMC slot, which is available from
the front panel. The slot is a single-width, mid-height slot. If needed, AMC I/O
connectivity can be accessed from the front panel (depending on the AMC installed)
and through the optional advanced rear transition module.
The Sun Netra CP3250 blade server conforms to the PICMG Advanced Mezzanine Card
AMC.0 specification R1.0 ECR_002 D0.9, June 29, 2006, and supports AMC.1 Type
8S2E2 cards, as defined by the same specification.
3-8
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
3.6.2
3.6.3
EIDE/ATA for Compact Flash
An EIDE/ATA-133 bus is derived from a SATA port on the ICH9 IO Hub via an
SPF223A SATA to IDE converter.
The Sun Netra CP3250 blade server contains one on-board 50-pin Type II Compact
Flash connector for use with a Compact Flash Card. The connector is located so that
access to the Compact Flash card is provided only when the card is removed from
the ATCA chassis.
SAS/SATA
The Sun Netra CP3250 blade server supports AMC drives (SAS or SATA), that
contain their own PCIe based controller chip connecting to the system via the PCIe
Bus. The Sun Netra CP3250 blade server supports an AMC that contains drives
using Port 2 or 3 SAS connections only when the Netra CP32x0 ARTM-HD is
present. The SATA lines from the ICH9 chip are not connected.
If present, the Netra CP32x0 ARTM-HD drives the AMC Port-2 signals. This support
speeds up to 3 Gb/sec.
There is no support for drives mounted directly to the blade server, and the Sun
Netra CP3250 blade server itself does not contain any native support for SAS or
SATA drives.
Chapter 3 Hardware Architecture
Download from Www.Somanuals.com. All Manuals Search And Download.
3-9
3-10
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER
4
This chapter contains the following sections:
■
■
■
■
Section 4.1, “Operating Systems” on page 4-2
Section 4.2, “Software Updates” on page 4-2
Section 4.3, “SunVTS Software” on page 4-3
Section 4.4, “Configuring Sun Netra CP3250 blade server For 1 GbE or 10 GbE
Switches” on page 4-4
4-1
Download from Www.Somanuals.com. All Manuals Search And Download.
4.1
Operating Systems
The Sun Netra CP3250 blade server has been tested for compatibility with the
following operating systems:
■
■
■
■
Solaris™ 10 (05/08) Operating System (Solaris OS)
WindRiver Linux 3.1
RedHat Linux 5.2
Windows 2003
Refer to the Netra CP3250 Blade Server Product Notes (820-5194) for information on
Solaris OS and patches.
For information on versions of the Solaris OS, including installation, see the
appropriate Solaris Documentation Collection at the Sun Documentation web site at:
For information on the WindRiver Linux, RedHat Linux, and Windows operating
systems, see the documentation that came with the operating system.
4.2
Software Updates
Software updates and support information for the Sun Netra CP3250 blade server,
ARTMs, and the Netra CT 900 system can be found at the Sun Download Center:
See the Netra CP3250 Blade Server Product Notes (820-5194) for information.
For information on your specific configuration, contact your local Sun Services
representative.
4-2
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
4.3
SunVTS Software
Note – The Sun Validation Test Suite (SunVTS software) runs on the Solaris OS only.
There are similar test suites available for the Linux operating systems.
The SunVTS software is a comprehensive software suite that tests and validates the
Sun Netra CP3250 blade server by verifying the configuration and function of most
hardware controllers and devices on the blade server.
SunVTS software is used to validate a system during development, production,
inspection, troubleshooting, periodic maintenance, and system or subsystem
stressing. SunVTS software can be tailored to run on various types of machines,
ranging from desktops to servers with modifiable test instances and processor
affinity features.
You can perform high-level system testing by using the appropriate version of
SunVTS software. For detailed information on SunVTS software support and
downloads, refer to the following web site:
http://www.sun.com/oem/products/vts/
You will be prompted for your Sun Online Account name and password.
Ensure that the SunVTS software version is compatible with the Solaris OS being
used. VTS 7.x is bundled with Solaris 10 OS (5/08) and newer.
You can find information about the SunVTS software version installed on your
system by using the following command:
# pkginfo -l SUNWvts
To obtain SunVTS documentation, contact your local Customer Service
representative, field applications engineer, or system support engineer.
Note – For security reasons, only a superuser is permitted to run SunVTS software.
Installation and starting instructions are included with the software when it is
downloaded.
Chapter 4 Software Configuration
Download from Www.Somanuals.com. All Manuals Search And Download.
4-3
4.4
Configuring Sun Netra CP3250 blade
server For 1 GbE or 10 GbE Switches
The extended fabric on the Sun Netra CP3250 blade server is capable of operating at
either 1 Gbps or 10 Gbps. The Sun Netra CP3250 blade server can be used in the
Netra CT 900 server with either the Netra CP3240 10-GbE switch or the Netra
CP3140 1-GbE switch. Therefore it is important that the driver configuration file be
modified accordingly.
If you are using the Solaris OS, the network interface driver configuration file,
nxge.conf, for the extended fabric ports of the Sun 10 GbE ASIC might need to be
modified to employ the proper switch and ARTM configurations. The nxge.conf
file is located in the /platform/i86pc/kernel/drvdirectory. The following
examples show the proper entries for each switch configuration.
Example 1: When extended fabric ports are connected to Netra CP3240 switches in
Slot 7 and Slot 8, the nxge.conffile should have the following entries:
name = "pciex108e,abcd" parent = "/pci@0,0/pci8086,65f8@4" unit-address ="0" phy-type = "xgsd";
name = "pciex108e,abcd" parent = "/pci@0,0/pci8086,65f8@4" unit-address ="0,1" phy-type =
"xgsd";
Example 2: When extended fabric ports are connected to Netra CP3140 switches in
Slot 7 and Slot 8, the nxge.conffile should have the following entries:
name = "pciex108e,abcd" parent = "/pci@0,0/pci8086,65f8@4" unit-address ="0" phy-type = "gsd";
name = "pciex108e,abcd" parent = "/pci@0,0/pci8086,65f8@4" unit-address ="0,1" phy-type = "gsd";
If you are using another OS, refer to the documentation that came with your OS.
4-4
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER
5
Configuring and Using BIOS
Firmware
This chapter describes how to use the BIOS (Basic Input Output System) to configure
the blade server.
This chapter contains the following procedures and information:
■
■
■
■
■
■
■
■
■
■
Section 5.1, “About BIOS Settings” on page 5-2
Section 5.2, “Changing the Configuration of a BIOS Menu Item” on page 5-3
Section 5.3, “Setting the Boot Device Using BIOS Setup Screens” on page 5-4
Section 5.4, “Setting Supervisor and User Passwords” on page 5-5
Section 5.5, “Resetting the System Time and System Date” on page 5-6
Section 5.6, “Updating the BIOS” on page 5-6
Section 5.7, “Secondary BIOS Image” on page 5-7
Section 5.8, “Perform a Live Firmware Upgrade” on page 5-8
Section 5.9, “Power-On Self-Test” on page 5-8
Section 5.10, “Changing POST Options” on page 5-9
5-1
Download from Www.Somanuals.com. All Manuals Search And Download.
5.1
About BIOS Settings
This section describes how to view and modify the BIOS settings.
The BIOS has a Setup utility stored in the BIOS flash memory. The Setup utility
reports system information and can be used to configure the BIOS settings. The
configured data is provided with context-sensitive help and is stored in the system's
battery-backed CMOS RAM. If the configuration stored in the CMOS RAM is
5.1.1
5.1.2
Navigating BIOS Screens
The BIOS Setup utility contains menu screens; see Appendix A for illustrations of
the screens.
Use the left and right arrow keys to move sequentially through the BIOS screens.
Fields that can be reconfigured are displayed in color. All other fields are
non-configurable. Use the up and down arrow keys to scroll through a screen's
menu. Use the Tab key to move across columns.
BIOS Option ROMs
The Sun Netra CP3250 blade server has an option ROM for each of the following
components:
■
Broadcom BCM 5715C base interfaces
■
Sun 10 GbE Multithreaded Networking Technolgy interfaces
Note – PXE boot from fabric interface (Sun 10GbE Multithreaded Networking
Technology interfaces) is disabled by default. You must change the BIOS setting to
boot from fabric interfaces.
5-2
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
5.1.3
Description of the BIOS Screens
TABLE 5-1 contains summary descriptions of the first-level BIOS Setup screens. For more
information about the BIOS screens and screen illustrations, see Appendix A.
TABLE 5-1
BIOS Setup Screens Summary
Screen
Description
Main
General system information.
Advanced
Configuration information for the CPUs, IDE, Super I/O, ACPI, Event
Log, PCI Express, Smbios, MPS, Remote Access, and USB.
Boot
Configure the boot device priority (hard disk drives and the ATAPI
DVD-ROM drive).
Security
Exit
Install or change the user and supervisor passwords.
Save or discard changes, or load optimal default BIOS settings.
5.2
Changing the Configuration of a BIOS
Menu Item
You can change the BIOS configuration by using a terminal (or terminal emulator
connected to a computer) through the serial console port on the front of the Sun
Netra CP3250 blade server.
BIOS screens.
1. To change the system’s parameters, enter the BIOS Setup utility by pressing the
F2 key while the system is performing the power-on self-test (POST).
See TABLE 5-1 for summary descriptions of the BIOS screens.
The first BIOS Setup menu screen is displayed.
2. Highlight the field to be modified using the arrow and Tab keys.
3. Press Enter to select the field.
A dialog box is displayed. The box displays the options that are available for the
setup field that you have chosen.
4. Modify the setup field and close the screen.
Chapter 5 Configuring and Using BIOS Firmware
Download from Www.Somanuals.com. All Manuals Search And Download.
5-3
5. To modify other setup parameters, use the arrow and Tab keys to navigate to the
appropriate screen and menu item; repeat Step 2 through Step 4.
6. Press and release the right arrow key until the Exit menu screen is displayed.
7. Follow the instructions on the Exit menu screen to save your changes and exit
the Setup utility.
5.3
Setting the Boot Device Using BIOS
Setup Screens
Before beginning this procedure, ensure that you have installed the serial cable as
described in Section 2.2.4, “Connecting External I/O Cables” on page 2-13.
Note – See Section 5.1.3, “Description of the BIOS Screens” on page 5-3 for
descriptions of the first-level BIOS menu screens. See Appendix A for illustrations of
the BIOS screens.
1. Use terminal emulation software to configure the serial COM1 settings.
Use the ANSI terminal type setting.
2. Set the serial communication settings to 9600 baud, 8 bit, 1 stop bit, no parity,
and no handshake.
3. Reset the ATCA shelf.
The BIOS starts running POST.
4. Press the F2 key to interrupt the boot and access the BIOS Main menu.
5. Using the arrow keys, move across the top of the screen to the Boot menu and
press the Enter key.
The Boot Settings menu is displayed.
6. Move down the list, select the Boot Device Priority option, and press Enter.
The Boot Device Priority menu is displayed.
7. Select the applicable device and priority.
8. Use the arrow keys to move to the Exit menu, and press Enter.
The confirmation dialog box is displayed.
5-4
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
9. Press Enter to select Ok.
The BIOS boots the selected device. The operating system on the selected boot
device loads.
10. Configure the operating system by providing a locale, system name, IP address,
and other information.
Refer to the documentation for your operating system for information on
configuring the operating system.
5.4
Setting Supervisor and User Passwords
You must set the Supervisor password before you can set the User password. The
Supervisor password sets the desired access level for the User password.
1. To reset any BIOS passwords, clear the CMOS settings by resetting Jumper 2.
See Section 2.3.10.1, “Clearing the CMOS Setting Using Jumper 2” on page 2-31
for details.
2. Enter the BIOS Setup utility by pressing the F2 key on the keyboard while the
system is performing the power-on self-test (POST).
3. Using the arrow keys, move across the top of the screen to the Security menu
and press the Enter key.
The Security Settings Menu is displayed.
4. Move down the list, select the Change Supervisor Password or Change User
Password option, and press Enter.
The Change Password menu is displayed.
5. Type a password, then press Enter.
6. Use the arrow keys to move to the Exit Menu.
7. Select OK to confirm the changes you made.
Chapter 5 Configuring and Using BIOS Firmware
Download from Www.Somanuals.com. All Manuals Search And Download.
5-5
5.5
Resetting the System Time and System
Date
1. Enter the BIOS Setup utility by pressing the F2 key while the system is
performing the power-on self-test (POST).
2. Press and release the right arrow key until the Exit menu is selected. Press the
Enter key.
3. Select the Load Optimal Defaults option and press the Enter key.
4. Use the arrow keys to return to the BIOS Main Menu.
5. Use the arrow keys to move down the main menu and reset the System Time
and System Date fields.
6. Use the arrow keys to move to the Exit Menu.
7. Choose Save Changes and Exit.
8. Select OK to confirm the changes you made.
5.6
Updating the BIOS
When they are updated, BIOS images will be available as patches at the following
web site:
http://sunsolve.sun.com/
Use the Solaris BIOS Update Utility or the Linux BIOS Update Utility to implement
the updates. For more information, see the Netra CT 900 Server Product Notes
(819-1180).
5-6
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
5.7
Secondary BIOS Image
The Sun Netra CP3250 blade server provides dual 1-Mbyte BIOS chips that support
redundant BIOS images for increased reliability. The default chip (page 0) acts as the
primary BIOS chip and is automatically selected for update during a firmware
upgrade. The secondary BIOS chip (page 1) retains the original BIOS image, and can
be used through manual configuration in the unlikely case where the primary BIOS
becomes corrupt.
If the primary BIOS becomes unbootable, use the secondary BIOS to manually boot
the blade server:
1. Log into the Shelf Manager.
2. To select the secondary BIOS image, type:
# clia sendcmd 96 2e 81 00 00 2a 01
For example:
# clia sendcmd 96 2e 81 00 00 2a 01 <----- Setting the boot page to 1
Pigeon Point Shelf Manager Command Line Interpreter
Completion code: 0x0 (0) <----- successful completion code
Response data: 00 00 2A
<----- no data returned
3. To boot the blade server from the Shelf Manager, type:
# clia activate board n
Note – Once the blade server is booted, reset the blade server to use the primary
BIOS image (page 0).
Chapter 5 Configuring and Using BIOS Firmware
5-7
Download from Www.Somanuals.com. All Manuals Search And Download.
5.8
5.9
To upgrade the BIOS firmware while retaining the current BIOS image, follow these
steps:
1. Switch the BIOS image from page0to page1.
2. Use the Solaris BIOS Update Utility to upgrade the page1BIOS image.
See Section 5.6, “Updating the BIOS” on page 5-6.
3. Reboot the system into the updated page1BIOS.
See Section 2.3.12, “Resetting the Netra CP3250 Blade Server” on page 2-34.
Power-On Self-Test
The system provides a rudimentary power-on self-test (POST) that runs each time
the blade server boots to check the basic devices required for the system to operate.
The progress of the self-test is indicated by a series of POST codes. These codes
appear at the bottom right corner of the system’s VGA screen (once the self-test has
progressed far enough to initialize the video monitor).
You can configure the level of POST testing and some POST display features through
the BIOS menus. For more information, see Section 5.10, “Changing POST Options”
on page 5-9.
5-8
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
5.10
Changing POST Options
These instructions are optional, but you can use them to change the operations that
the server performs during POST testing.
1. Initialize the BIOS Setup utility by pressing the F2 key while the system is
performing the power-on self-test (POST).
The BIOS Main Menu screen is displayed.
2. From the BIOS Main Menu screen, select the Boot menu.
3. From the Boot Settings screen, select Boot Settings Configuration.
4. On the Boot Settings Configuration screen, you can enable or disable the
options shown in TABLE 5-2
TABLE 5-2
POST Options
Option
Description
Quick Boot
This option is disabled by default. If you enable Quick Boot, the BIOS skips certain tests
while booting, such as the extensive memory test. This decreases the time it takes for the
system to boot.
Quiet Boot
This option is disabled by default.
Chapter 5 Configuring and Using BIOS Firmware
Download from Www.Somanuals.com. All Manuals Search And Download.
5-9
5-10
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
A-16
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX
B
Specifications for the Sun Netra CP3250 blade server are provided in the following
sections:
■
■
■
Section B.1, “Form Factor” on page B-2
Section B.2, “Power and Thermal Metrics” on page B-2
Section B.3, “Connectors and Pinouts” on page B-2
B-1
Download from Www.Somanuals.com. All Manuals Search And Download.
B.1
B.2
Form Factor
The Sun Netra CP3250 blade server is a standard 8-rack unit (8U) factor, single-slot
wide. It complies with the board mechanical dimensions that are required by the
PICMG 3.0 specification:
■
322.25 mm x 280 mm (12.7 inches x 11.0 inches)
30.48 mm (1.2 inch) front panel
■
Power and Thermal Metrics
Typical heat dissipation and power consumption metrics for a Sun Netra CP3250
blade server:
■
225W maximum power (includes 25W to ARTM, 20W to AMC, and two Intel
Harpertown CPUs)
■
■
■
-5C - 55C for NEBS compliance
Power input: -36 VDC to -72 VDC (-48VDC nominal)
CPU temperature thresholds are set relative to the Thermal Control Circuit (TCC)
activation point of the Intel Harpertown CPUs. An offset of 95C is added to
provide an approximate CPU die temperature.
Two heatsinks are mounted to the Sun Netra CP3250 blade server. The heatsinks and
DIMMs are positioned on the blade server to provide adequate airflow (bottom to
top).
B.3
Connectors and Pinouts
B.3.1
Front Panel Connectors
The front panel has the following connectors, see FIGURE 1-1:
■
■
■
One 10/100/1000BASE-T Ethernet port (RJ-45)
One serial port (RJ-45)
Two USB ports
B-2
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
B.3.1.1
Ethernet Port
The Ethernet connector is an RJ-45 connector. The controller autonegotiates to either
10 BASE-T, 100 BASE-T, or 1000 BASE-T.
FIGURE B-1 shows the Ethernet port connector.
FIGURE B-1 Ethernet RJ-45 Connector
1 2 3 4 5 6 7 8
TABLE B-1 provides the eight pin assignments for the Ethernet port connector.
TABLE B-1 Ethernet Port Connector Pin Assignments
Pin
1
Signal Name
DA+
Pin
5
Signal Name
DC-
2
DA-
6
DB-
3
DB+
7
DD+
4
DC+
8
DD-
Appendix B Physical Characteristics
B-3
Download from Www.Somanuals.com. All Manuals Search And Download.
B.3.1.2
USB Ports
FIGURE B-2 shows the connector pin assignments for both of the front panel USB
ports.
FIGURE B-2 Front Panel USB Connector
1
4
TABLE B-3 lists the USB port connector pin assignments.
TABLE B-2 USB Port Pin Assignments
Pin
1
Signal Name
VCC
Description
+5 VDA (500ma)
Data-
2
D-
3
D+
Data+
4
GND
Ground
B-4
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
B.3.1.3
Serial Port
FIGURE B-3 shows the connector pin assignments for the front panel serial port.
FIGURE B-3 Front Panel Serial RJ-45 Connector
1 2 3 4 5 6 7 8
TABLE B-3 lists the serial port connector pin assignments.
TABLE B-3 Serial Port Mini DIN 8-pin Connector Pinouts
Pin
1
Signal Name
RTS
Pin
5
Signal Name
GND
2
DTR
6
RXD
3
TXD
7
DSR
4
GND
8
CTS
B.3.2
AMC Connector
One 170-pin connector provides the AMC connection. The connector and pinouts are
defined by the industry-standard specification PICMG Advanced Mezzanine Cards
AMC.0 Specification R1.0 ECR-002 D0.9, June 29, 2006.
The AMC slot is available at the front panel. The AMC can be accessed from the
front panel, depending on the features of the AMC, or through an optional advanced
rear transition module (ARTM).
Appendix B Physical Characteristics
Download from Www.Somanuals.com. All Manuals Search And Download.
B-5
B.3.3
Power Connector (Zone 1)
The Sun Netra CP3250 blade server uses a 34-pin Positronic connector as the Zone 1
power distribution connector. It provides the support for the following signals:
■
■
■
Two -48 VDC power feeds (four signals each; eight signals total)
Two IPMB ports (two signals each; four signals total)
Geographic address (eight signals)
The analog test and ring voltage pins are left unconnected. FIGURE B-4 shows the pin
assignments.
FIGURE B-4 Power Distribution Connector (Zone 1) P10
1
13 17
21
25
26
28
29
30
31
33
34
27
32
4
16 20
24
TABLE B-4 lists the power distribution connector pin assignments.
TABLE B-4 Power Distribution Connector Pin Assignments
Pin Number
Name
Description
1
2
3
4
5
6
7
8
9
Reserved
Reserved
Reserved
Reserved
HA0
Reserved
Reserved
Reserved
Reserved
HA0 Hardware Address Bit 0
HA1 Hardware Address Bit 1
HA2 Hardware Address Bit 2
HA3 Hardware Address Bit 3
HA4 Hardware Address Bit 4
HA1
HA2
HA3
HA4
B-6
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE B-4 Power Distribution Connector Pin Assignments (Continued)
Pin Number
10
Name
Description
HA5
HA5 Hardware Address Bit 5
HA6 Hardware Address Bit 6
HA7/P Hardware Address Bit 7 (Odd Parity Bit)
IPMB Clock, Port A
IPMB Data, Port A
IPMB Clock, Port B
IPMB Data, Port B
11
HA6
12
HA7/P
13
SCL_A
14
SDA_A
15
SCL_B
16
SDA_B
17
MT1_TIP
MT1_TIP
-RING_A
-RING_B
MT1_RING
MT2_RING
-RING_A
-RING_B
SHELF_GND
LOGIC_GND
ENABLE_B
VRTN_A
VRTN_B
EARLY_A
EARLY_B
ENABLE_A
-48V_A
Metallic Test #1 Tip
Metallic Test #2 Tip
Ringing Generator A Negative Ringing
Ringing Generator B Negative Ringing
Metallic Test #1 Ringing
Metallic Test #2 Ringing
Ringing Generator AReturn
Ringing Generator B Return
Shelf Ground
18
19
20
21
22
23
24
25
26
Logic Ground
27
Enable B
28
Voltage Return A
29
Voltage Return B
30
-48V Early A
31
-48V Early B
32
Enable A
33
-48V A
34
-48V_B
-48V B
Appendix B Physical Characteristics
B-7
Download from Www.Somanuals.com. All Manuals Search And Download.
B.3.4
Data Transport Connector (Zone 2)
The data transport connector consists of two 120-pin HM-Zd connectors, labeled P20
and P23, with 40 differential pairs each. These are called the Zone 2 connectors.
The Zone 2 connectors provides the following signals:
■
■
Two 10/100/1000BASE-T/TX Ethernet base fabric channels (four differential
signal pairs each; 16 signals total)
Two 10-Gbit SERDES ports on the extended fabric (eight differential signal pairs
each; 32 signals total)
The connector vendor part number is Tyco: 1469001-1.
FIGURE B-5 Zone 2 Connector
B.3.5
Advanced Rear Transition Module (ARTM)
Connector (Zone 3)
The Sun Netra CP3250 blade server provides all the I/O connections for rear access
through the Zone 3 advanced rear transition module (ARTM) connector. The
connector view and the pinout for the Zone 3 connector are shown in FIGURE B-6.
B-8
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
Zone 3 connector pinouts are presented from the point of view of the ATCA blade,
meaning that TX means the ATCA blade is the signal source and the ARTM is the
signal receiver. Similarly RX means the ATCA blade is the signal receiver and the
ARTM is the signal source.
The “reserved” pins indicate connector pins that are currently reserved for
compatibility to all ARTMs. Do not connect signals to reserved pins. The “no
connect” indicates pins that should not be connected by the Sun Netra CP3250 blade
server.
FIGURE B-6 Zone 3 Connector
Appendix B Physical Characteristics
Download from Www.Somanuals.com. All Manuals Search And Download.
B-9
B.3.5.1
Zone 3 (J30) Connector Pin Assignments
TABLE B-6 shows the J30 connector pin assignments, used for power signals.
TABLE B-5 J30 Pin Connector Assignments
1-3
4-6
Pin Length
short
Mating Sequence
last
E
PS1#
NC
D
C
+12V PP
IPMI_SCL_L
+12V PP
long
first
IPMI_SDA medium
_L
Second
B
Logic_GND
Logic_GND
+3.3V_MP
long
First
First
A
Shelf_GND long
B.3.5.2
Zone 3 (J31) Connector PIN Assignments
TABLE B-7 shows the J31 connector pin assignments, used for ARTM signals.
TABLE B-6 J31 Connector Pin Assignments
Row Interface
AB
BG
CD
DG
EF
FG
1
2
3
4
AMC0
EO
RTM_TX13 RTM_TX13 GND RTM_RX RTM_RX GND RTM_TX12 RTM_TX12 GND
+ (AMC0
- (AMC0
12+
12-
+ (AMC0
- (AMC0
EO_Rx1+) EO_Rx1-)
(AMC0
(AMC0
EO_Rx0+) EO_Rx0-)
EO_Tx0+ EO_Tx0-)
)
AMC0
EO
RTM_RX14 RTM_RX14 GND RTM_TX RTM_TX GND RTM_RX13 RTM_RX13 GND
+ (AMC0
- (AMC0
14+
14-
+ (AMC0
- (AMC0
EO_Tx2+) EO_Tx2-)
(AMC0
(AMC0
EO_Tx1+) EO_Tx1-)
EO_Rx2+ EO_Rx2-
)
)
AMC0
EO
RTM_TX17 RTM_TX17 GND RTM_RX RTM_RX GND RTM_TX15 RTM_TX15 GND
+ (AMC0
- (AMC0
15+
15-
+ (AMC0
- (AMC0
EO_Rx4+) EO_Rx4-)
(AMC0
(AMC0
EO_Rx3+) EO_Rx3-)
EO_Tx3+ EO_Tx3-)
)
AMC0
EO
RTM_RX18 RTM_RX18 GND RTM_TX RTM_TX GND RTM_RX17 RTM_RX17 GND
+ (AMC0
- (AMC0
18+
18-
+ (AMC0
- (AMC0
EO_Tx5+) EO_Tx5-)
(AMC0
(AMC0
EO_Tx4+) EO_Tx4-)
EO_Rx5+ EO_Rx5-
)
)
B-10
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE B-6 J31 Connector Pin Assignments (Continued)
Row Interface
AB
BG
CD
DG
EF
FG
5
AMC0
EO
RTM_TX20 RTM_TX20 GND RTM_RX RTM_RX GND RTM_TX19 RTM_TX19 GND
+ (AMC0
- (AMC0
19+
19-
+ (AMC0
- (AMC0
EO_Rx7+) EO_Rx7-)
(AMC0
(AMC0
EO_Rx6+) EO_Rx6-)
EO_Tx6+ EO_Tx6-)
)
6
AMC0
EO
Reserved
Reserved
GND Reserved Reserved GND RTM_RX20 RTM_RX20 GND
+ (AMC0 - (AMC0
EO_Tx7+) EO_Tx7-)
7
Reserved Reserved
Reserved Reserved
Reserved Reserved
Reserved Reserved
Reserved
Reserved
Reserved
GND Reserved Reserved GND Reserved
Reserved
Reserved
Reserved
Reserved
GND
GND
GND
GND
8
GND Reserved Reserved GND Reserved
GND Reserved Reserved GND Reserved
GND Reserved Reserved GND Reserved
9
10
B.3.5.3
Zone 3 (J32) Connector PIN Assignments
TABLE B-8 shows the J32 connector pin assignments, used for ARTM signals.
TABLE B-7 J32 Connector Pin Assignments
Row Interface
AB
BG
CD
DG
EF
FG
1
2
Reserved Reserved
Reserved
GND Reserved
Reserved
GND Reserved
Reserved
GND
SAS
SAS TX0+ SAS TX0- GND SAS RX0+ SAS RX0- GND RTS (Serial DTR
GND
AMC0
(AMC0
(AMC0
(AMC0
(AMC0
0)
(Serial 0)
SAS0_Rx+) SAS0_Rx-)
SAS0_Tx+) SAS0_Tx-)
3
4
Reserved Reserved Reserved
GND Reserved Reserved
GND TXD
RXD
(Serial 0)
GND
(Serial 0)
SAS
SAS TX2+ SAS TX2- GND SAS RX2+ SAS RX2- GND DSR
CTS (Serial GND
0)
AMC0
(AMC0 (AMC0 (AMC0 (AMC0 (Serial 0)
SAS1_Rx+) SAS1_Rx+) SAS1_Rx+) SAS1_Rx+)
5
6
Reserved Reserved Reserved GND Reserved Reserved
GND No
Connect
No
Connect
GND
GND
RTM
LAN0_A+ LAN0_A- GND LAN0_CT LAN0_CT GND LAN0_B+ LAN0_B-
LAN0
(Mgmt)
V
V
7
RTM
LAN0
(Mgmt)
LAN0_C+ LAN0_C- GND ACT_LED LINK_LE GND LAN0_D+ LAN0_D- GND
D#
#
Appendix B Physical Characteristics
Download from Www.Somanuals.com. All Manuals Search And Download.
B-11
TABLE B-7 J32 Connector Pin Assignments (Continued)
Row Interface
AB
BG
CD
DG
EF
FG
8
9
RTM
LAN1
(SerDes)
SLAN_TX SLAN_TX GND SLAN_RX SLAN_RX GND No
1+ 1- 1+ 1- Connect
No
Connect
GND
RTM
SLAN_TX SLAN_TX GND SLAN_RX SLAN_RX GND SLAN_TX SLAN_TX GND
LAN2/L 2+
AN4
2-
2+
2-
4+
4-
(SerDes)
10
RTM
SLAN_TX SLAN_TX GND SLAN_RX SLAN_RX GND SLAN_RX SLAN_RX GND
LAN3/L 3+
AN4
3-
3+
3-
4+
4-
(SerDes)
B.3.5.4
Zone 3 (J33) Connector PIN Assignments
TABLE B-9 shows the J33 connector pin assignments, which are used ARTM signals.
TABLE B-8 J33 Connector Pin Assignments
Row Interface
AB
BG
CD
DG
EF
FG
1
PCIe x8
Lane
PETx0+
PETx1+
PETx2+
PETx3+
PETx4+
PETx5+
PETx6+
PETx7+
PETx0-
GND
PERx0+ PERx0-
GND
FCLKA+ FCLKA- GND
TCLKA+ TCLKA- GND
TCLKB+ TCLKB- GND
TCLKC+ TCLKC- GND
TCLKD+ TCLKD- GND
2
PCIe x8
Lane
PETx1-
PETx2-
PETx3-
PETx4-
PETx5-
PETx6-
PETx7-
No
GND
GND
GND
GND
GND
GND
GND
GND
GND
PERx1+ PERx1-
PERx2+ PERx2-
PERx3+ PERx3-
PERx4+ PERx4-
PERx5+ PERx5-
PERx6+ PERx6-
PERx7+ PERx7-
GND
GND
GND
GND
GND
GND
GND
GND
GND
3
PCIe x8
Lane
4
PCIe x8
Lane
5
PCIe x8
Lane
6
PCIe x8
Lane
TCK
TMS
TDO
GND
GND
7
PCIe x8
Lane
TRST#
TDI
8
PCIe x8
Lane
PCI_RST GND
#
9
Reserved No
No
No
ARTM#
PS0#
PCI_CFG GND
Connect Connect
Connect Connect
10
Reserved No
No
No No
Enabled# GND
Connect Connect
Connect Connect
B-12
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
B.3.5.5
Zone 3 Signal Descriptions
TABLE B-10 provides descriptions of the signals listed in the Zone 3 pin assignment
tables (TABLE B-6 through TABLE B-9).
TABLE B-9 Zone 3 Signal Descriptions
Signal Name
Description
IPMI_SCL_L
IPMI bus clock signal, as defined in AMC.0 specification. RTM shall have a pull-up
resistor for this signal as indicated in AMC.0 specification.
IPMI_SDA_L
PS0#, PS1#
IPMI bus data signal, as defined in AMC.0 specification. RTM shall have a pull-up
resistor for this signal as indicated in AMC.0 specification.
Active low RTM present signal.PS0# shall be tied to logic GND on the ATCA blade, PS1#
shall be pulled up to 3.3V Management Power on the ATCA blade, PS0# and PS1# shall
be connected through diode on RTM, exactly as defined in AMC.0 specification. PS1# is
last mate on Power connector and PS0# is on the opposite end of the set of connectors.
Logic low on PS1# indicates that RTM is present and fully inserted.
Enable#
When low indicates to RTM that it is fully inserted and that MMC can start execution.
Logic high shall keep MMC in reset state. This signal shall have a pull-up resistor as
indicated in AMC.0 specification.
Shelf_GND
Logic_GND
Frame/Chassis Safety Ground.
(Logic 0vdc). Logic Ground- Common return for Management Power Payload Power,
reference potential for single-ended logic signaling, and shielding for differential pair
signals in the AMC Connector.
12VPP
12V Payload Power, enabled after successful E-keying, following AMC.0 specification.
RTM shall meet requirements posted for payload power in AMC specification.
3.3V_MP
RTM_RX
3.3V Management Power. RTM shall meet requirements posted for management power in
AMC.0 specification.
AMC Extended Options receive differential pair signals. Note that this specification takes
ATCA Blade perspective, which means that RX signals are driven by RTM and received
by ATCA Blade.
RTM_TX
AMC Extended Options transmit differential pair signals. Note that this specification
takes ATCA Blade perspective, which means that TX signals are driven by ATCA Blade
and received by RTM.
SAS_TX
SAS_RX
Serial 0
SATA/SAS transmit differential pair signals.
SATA/SAS receive differential pair signals.
RS-232 Serial Signals, Transmit, Receive, Clear to Send, Request to Send, Data Terminal
Ready, and Data Set Ready.
LAN0
10/100/1000BASE-T signals.
LAN0_CTV
10/100/1000BASE-T transformer Center Tap signal, which could be used to terminate
center tap of transformers, if they are placed on RTM. This signal is applicable if Ethernet
PHY is located on ATCA blade, while transformers are located on RTM.
Appendix B Physical Characteristics
Download from Www.Somanuals.com. All Manuals Search And Download.
B-13
TABLE B-9 Zone 3 Signal Descriptions (Continued)
Signal Name
ACT_LED#
LINK_LED#
PCI_CFG
Description
LAN 0 (Management) activity indicator signal for LED (active low).
LAN 0 (Management) LINK indicator signal for LED (active low).
PCI Express bus configuration signal. It shall be grounded on RTMs that use a single x8
PCI Express bus and pulled up on the ATCA with 10Kohm resistor to management
power. On RTMs that expect two x4 PCI-Express busses this pin will float (not be
connected). Two x4 PCI-Express busses are intended for RTM implementations that
desire to avoid PCI-Express switch in order to reduce latency.
ARTM#
ARTM# signal shall be grounded on ARTMs that implement MMC controller as defined
by AMC.0 specification. This signal shall be pulled up with 10Kohm resistor to
management power on the ATCA node blade server.
SLAN_TX
SLAN_RX
PETx
GBEthernet SerDes transmit differential pair signals.
GBEthernet SerDes receive differential pair signals.
PCI-Express transmit differential pair signals.
PCI-Express receive differential pair signals.
PERx
PCI_RST#
PCI-Express reset signal. Logic low shall reset downstream PCI-Express devices on
ARTM.
TCLKA
TCLKB
TCLKC
TCLKD
FCLKA
PCI-Telecom clock A 19.44MHz, differential pair into RTM (ATCA CLK2) as defined in
AMC.0 specification.
PCI-Telecom clock B 19.44MHz, differential pair out from RTM (ATCA CLK3) as defined
in AMC.0 specification.
PCI-Telecom clock C 8kHz, differential pair into RTM (ATCA CLK1) as defined in AMC.0
specification.
PCI-Telecom clock D 8kHz, differential pair out from RTM as defined in AMC.0
specification.
Fabric clock, as defined in AMC.0 specification. Intended to be used for PCI-Express 100
MHz spread spectrum clock.
TCK, TMS, TRST#,
TDO, TDI
JTAG signals. Signal direction shall follow AMC.0 specification.
B-14
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix B Physical Characteristics
Download from Www.Somanuals.com. All Manuals Search And Download.
B-15
B-16
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX
C
ShMM CLI and Commands
This appendix provides information about using the ShMM CLI and most
commonly used ShMM commands.
This appendix contains the following topics:
■
“Shelf Manager Command-Line Interface” on page 2
“Shelf Manager CLI Commands” on page 3
■
C-1
Download from Www.Somanuals.com. All Manuals Search And Download.
C.1
Shelf Manager Command-Line Interface
The Shelf Manager command-line interface (CLI) can be used to communicate with
the intelligent management controllers of the shelf, with blade servers, and with the
Shelf Manager itself, through text commands. The CLI is an IPMI-based set of
commands that can be accessed directly or through a higher-level management
application or a script. Administrators can access the CLI through a Telnet
connection or the shelf management card serial port. Using the CLI, operators can
access information about the current state of the shelf including current FRU
population, current sensor values, threshold settings, recent events, and overall shelf
health.
▼ To Start the Command-Line Interface
1. To use the CLI, first log on to the Linux operation system on the shelf
management card.
2. Once logged in, run the executable cliafrom the command line with specific
parameters.
The first parameter is the command verb. The cliaexecutable is located on the
virtual rootfile system maintained by Linux running on the shelf management
card. The cliaexecutable connects to the main Shelf Manager software process,
passes the command information to it, and retrieves the results. The Shelf
Manager must be running prior to starting the CLI. For example:
# clia ipmc 20
Pigeon Point Shelf Manager Command Line Interpreter
20: Entity: (d0, 0) Maximum FRU device ID: 20
PICMG Version 2.0
Hot Swap State: M4, Previous: M3, Last State Change Cause: Normal State Change
(0)
#
C-2
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
If started without parameters, cliaenters an interactive mode. In that mode, the
program repeatedly issues a prompt to the terminal, accepts user input as the
next command with parameters, executes that command, and shows the results
on the terminal, until the user types the command exitor quit. For example:
# clia
Pigeon Point Shelf Manager Command Line Interpreter
CLI> ipmc 20
20: Entity: (d0, 0) Maximum FRU device ID: 20
PICMG Version 2.0
Hot Swap State: M4, Previous: M3, Last State Change Cause: Normal State Change
(0)
CLI> exit
#
C.2
Shelf Manager CLI Commands
The Shelf Manager CLI implements the following commands. They are described in
detail in the Netra CT 900 Server System Administration Manual (819-1177), with a
subsection for each command, in alphabetical order of the command names. For the
web site URL, see “Related Documentation” on page xv.
TABLE C-1 Shelf Manager CLI Command Summary
Command
Parameters
Description
activate
IPMB address
FRU device ID
Activates the specified FRU.
alarm
alarm type
Activates or clears Telco alarms.
board -v
boardreset
console
slot number (optional)
slot number
Shows information about blade servers.
Resets the specified ATCA blade server.
slot number
Opens a console session on the node
blade server in the specified slot.
deactivate
IPMB address
FRU device ID
Deactivates the specified FRU.
exit|quit
Exits from the interpreter in interactive
mode.
Appendix C ShMM CLI and Commands
C-3
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE C-1 Shelf Manager CLI Command Summary (Continued)
Command
Parameters
Description
fans
IPMB address (optional)
FRU device ID (optional)
Shows information about fans.
fru
IPMB address (optional)
FRU device ID (optional)
FRU type (optional)
Shows information about one or a group
of FRUs in the shelf; FRUs are selected
by type or by the parent IPM controller.
frudata
IPMB address (optional)
FRU device ID (optional)
block/byte offset (optional)
data (optional)
Provides raw access to the FRU.
Information on the specified FRU.
frudatar
frudataw
fruinfo -v
IPMB address
FRU device ID
File name
Reads the FRU data area of the specified
FRU and stores the data in the specified
file.
IPMB address
FRU device ID
File name
Writes the FRU data in the specified file
into the FRU data area of the specified
FRU.
IPMB address
FRU device ID
Provides user-friendly FRU Information
output.
getthreshold|
threshold
IPMB address (optional)
sensor name (optional)
sensor number (optional)
Shows threshold information about a
specific sensor.
help
ipmc
Shows the list of supported commands.
IPMB address (optional)
fan level (optional)
Shows information about one or all IPM
controllers in the shelf.
minfanlevel
ps -ef |grep hp
sensor
Shows or sets the minimum fan level.
Checks the openhpistatus.
IPMB address (optional)
sensor name (optional)
sensor number (optional)
Shows information about one or a group
of sensors; sensors are selected by IPM
controller address, number or name.
sensordata
sensorread
IPMB address (optional)
sensor name (optional)
sensor number (optional)
Shows value information for a specific
sensor.
IPMB address
sensor number
Shows raw value information for a
specific sensor (ignoring any Sensor Data
Record describing the sensor).
C-4
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE C-1 Shelf Manager CLI Command Summary (Continued)
Command
Parameters
Description
setfanlevel
IPMB address
FRU device ID
level
Sets a new level for the fan controlled by
the specified FRU.
Use clia setfanlevel 20 3 5to get
the fans to slow down.
setfanpolicy
setthreshold
IPMB address
Enables or disables fan trays for cooling
management in addition to the Fan
Geography record if this one is presented
in the Shelf FRU.
FRU device ID
action to be taken: ENABLEor DISABLE
timeout (optional)
site type (optional)
site number (optional)
IPMB address
sensor name
Changes a specific threshold value
(upper/lower,
critical/non-critical/non-recoverable) for
a specific sensor.
sensor number
threshold type
threshold value
setuserlabel
shelf
shelf name
Configures user assigned names for the
shelf and the blade servers. Blade server
names are assigned to slot numbers.
slot number name
subcommand, with its parameters
Shelf Address string (optional)
Shows general information about the
shelf; several subcommands allow
setting shelf attributes and getting
additional information about specific
areas.
shelfaddress
Gets or sets the Shelf Address field of the
Address Table within Shelf FRU
Information.
shelf address_table
Shows the address table record in the
shelf FRU info with shelf address and list
of address table entries. For each entry,
shows hardware address, site type, and
site number.
shelf cooling_state
shelf fans_state
Shows the current cooling state of the
shelf with normal, minor, major, and
critical alert information.
Shows the current state of the fan
techometers in the shelf with normal,
minor, major and critical alert
information.
shmstatus
Shows the Shelf Manager Active/Backup
status.
Appendix C ShMM CLI and Commands
Download from Www.Somanuals.com. All Manuals Search And Download.
C-5
TABLE C-1 Shelf Manager CLI Command Summary (Continued)
Command
Parameters
Description
showhost
slot-number
Displays version information about the
firmware on certain Netra CP3x60 node
blade servers.
showunhealthy
switchover
terminate
version
Shows the unhealthy components of the
shelf.
Initiates a switchover to the backup Shelf
Manager.
Terminates the Shelf Manager without
rebooting the shelf management card.
Shows the Shelf Manager version
information.
Most informational commands support brief and verbose modes of execution,
differing in the amount of information provided. Brief mode is the default
(standard); verbose mode is selected by using the option -vin the command line,
directly after the command and before the positional arguments. Commands that are
executed on the backup Shelf Manager can only access objects (such as sensors,
FRUs, IPM controllers) that are local to the backup Shelf Manager.
To help the user to determine whether a specific command is being executed on the
active or on the backup Shelf Manager, the following message is issued when a CLI
command is executed on the backup Shelf Manager: RunningontheBackup
ShelfManager,withlimitedfunctionality.
C-6
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
system console, 2-15
A
AMC cards supported, 1-8
AMC devices
installing, 2-24
connectors, B-2
B
BIOS
about settings, 5-2
contacting support, 1-13
matching pairs, 2-19
removing, 2-23
PCI Express Configuration, A-10
Remote Access Configuration, A-9
E
Boot Settings Configuration menu, A-13
booting, 1-7
F
front panel, B-5
C
H
cabling, 2-14
installing, 2-13
hardware installation, 2-1 to 2-30
Index-1
Download from Www.Somanuals.com. All Manuals Search And Download.
preparation, 2-4
changing options, 5-9
power connector, B-6
power off, 2-17
rear transition modules, 2-8
hot-swap support, 1-11
connector, B-9
features, 1-8
I
removing the board, 2-18
installation
requirements
hardware, 1-12
safety, 2-2
AMC device, 2-27
DIMMs, 2-21
preparation, 2-4
rear transition modules, 2-8
J
number, locating, 1-13
port, B-5
Jumper 1
M
MAC address, 2-5
label, 1-14
memory, 3-4
DIMM requirements, 2-19
menu, See BIOS menus
software
OS support, 4-2
SunVTS, 4-3
SunVTS software, -xiii, 4-3
support, contacting, 1-13
N
netinstall boot device, 2-15
switches, configuring for 1GbE or 10GbE, 4-4
O
warranty, 1-13
P
part number, locating, 1-14
password changing BIOS, 5-5
PCI Express Configuration menu, A-10
pinouts, B-2
Index-2
Sun Netra CP3250 Blade Server User’s Guide • April 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
|
Sharp All in One Printer AM 900 User Manual
Sharp Calculator EL 9450 User Manual
Snapper Lawn Aerator 2385 User Manual
Snapper Lawn Mower ZM5202M MZ2301KH ZM6102M MZM5203M User Manual
Soleus Air Patio Heater HP1 15 50 User Manual
Sony Cell Phone 1272 9183 User Manual
Sony Computer Monitor CPD E430 User Manual
Sony Marine GPS System MZ B100 User Manual
Speco Technologies Security Camera CVC5845DNV User Manual
Sylvania VCR SRV2306 User Manual