OPERATION AND PARTS MANUAL
MODELCP-20H
CENTRIFUGAL PUMP
MODEL #
SERIAL #
Revision #0 (05/30/03)
STOWCONSTRUCTIONEQUIPMENT
A DIVISION OF MULTIQUIP INC.
POST OFFICE BOX 6254
PARTS DEPARTMENT:
800-427-1244
FAX: 800-672-7877
SERVICE DEPARTMENT/TECHNICAL ASSISTANCE:
800-478-1244
CARSON, CA 90749
310-537-3700 • 888-252-STOW [888-252-7869]
FAX:310-537-1986 • FAX:800-556-1986
E-MAIL: [email protected] • WWW: stowmfg.com
FAX:310-631-5032
Download from Www.Somanuals.com. All Manuals Search And Download.
HERE'S HOW TO GET HELP
PLEASE HAVE THE MODEL AND SERIAL
NUMBER ON-HANDWHEN CALLING
PARTS DEPARTMENT
800-427-1244 or 310-537-3700
FAX: 800-672-7877 or 310-637-3284
SERVICE DEPARTMENT
800-421-1244
FAX: 310- 537-4259
TECHNICAL ASSISTANCE
800-478-1244
FAX: 310- 631-5032
WARRANTY DEPARTMENT
888-661-4279, or 310-661-4279
FAX: 310- 537-1173
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 3
Download from Www.Somanuals.com. All Manuals Search And Download.
STOW CP-20H — TABLE OF CONTENTS
HondaGX120K1PX2 Engine
STOW CP-20H Gasoline
Air Cleaner (Dual) Assembly.............................. 32-33
Powered Centrifugal Pump
Here’s How To Get Help ............................................ 3
Table of Contents ...................................................... 4
Parts Ordering Procedures ....................................... 5
Pump Specifications/Dimensions ...............................6
Engine Specifications .................................................7
Safety Message Alert Symbols .............................. 8-9
Rules For Safe Operation .................................. 10-11
General Information .................................................12
Pump Components ..................................................13
Basic Engine ............................................................14
Pre-Inspection (Engine) ...........................................15
Pre-Set-up (Pump)...................................................16
Initial Start-up (Engine) ...................................... 17-18
Maintenance (Pump) ......................................... 20-21
Maintenance (Engine)........................................ 22-23
Preparation for Long-Term Storage.........................24
Troubleshooting (Pump)...........................................26
Troubleshooting (Pump/Engine) ..............................27
Explanation Of Code In Remarks Column ...............28
Suggested Spare Parts ............................................29
Pump Assy. ........................................................ 30-31
Camshaft Assembly ........................................... 34-35
Carburetor Assembly ......................................... 36-37
Control Assembly ............................................... 38-39
Crankcase Cover Assembly............................... 40-41
Crankshaft Assembly ......................................... 42-43
Cylinder Barrel Assembly................................... 44-45
Cylinder Head Assembly.................................... 46-47
Fan Cover Assembly .......................................... 48-49
Flywheel Assembly ............................................ 50-51
Fuel Tank Assembly ........................................... 52-53
Ignition Coil Assembly ........................................ 54-55
Muffler Assembly ............................................... 56-57
Piston Assembly................................................. 58-59
Recoil Starter Assembly..................................... 60-61
Gasket Kit Assembly .......................................... 62-63
Labels ................................................................ 64-65
Terms and Condition Of Sale
—
Parts .................... 66
Specification and part number
are subject to change without
notice.
PAGE 4 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
PARTS ORDERING PROCEDURES
When ordering parts,
please supply the following information:
❒
Dealeraccountnumber
❒
❒
❒
❒
❒
❒
Dealernameandaddress
Shipping address (if different than billing address)
Returnfaxnumber
Applicable model number
Quantity,part number and description of each part
Specifypreferredmethodofshipment:
Note:Unlessotherwiseindicatedbycustomer, all
orders are treated as “Standard Orders”, and will
ship within 24 hours.We will make every effort to
ship “Air Shipments” the same day that the order is
received, if prior to 2PM west coast time. “Stock
Orders” must be so noted on fax or web forms.
✓
✓
✓
✓
✓
✓
FedEx or UPS Ground
FedEx or UPS Second Day or Third Day
FedEx or UPS Next Day
Federal Express Priority One
DHL
Truck
Place Your Parts Order Via Web or Fax
For Even More Savings!
Here’s how to get help...
Please have the model and serial number on
hand when calling.
Parts Department
Extra Discounts!
800-427-1244
310-537-3700
Fax:800-672-7877
Fax:310-637-3284
All parts orders which include complete part numbers
and are received by our automated web parts order
system, or by fax qualify for the following extra
discounts:
Mayco Parts
800-306-2926
310-537-3700
Fax:800-672-7877
Fax:310-637-3284
Ordered
via
Standard
orders
Stock orders
($750 list and above)
Service Department
800-478-1244
310-537-3700
Fax
3%
5%
10%
10%
Fax:310-537-4259
Web
MQ Power Service Department
Special freight allowances
when you order 10 or more
line items via Web or Fax!**
FedEx Ground Service at no charge for freight
800-835-2551
310-537-3700
Fax:310-638-8046
Warranty Department
800-421-1244, Ext. 279
310-537-3700, Ext. 279
Fax:310-537-1173
No other allowances on freight shipped by any other
carrier.
Multiquip’s Main Phone Numbers
800-421-1244
310-537-3700
Fax:310-537-3927
NOTE:DISCOUNTSARESUBJECTTOCHANGE
MULTIQUIP INC.
Direct TOLL-FREE access
to our Parts Department:
Toll-free nationwide — 800-427-1244
18910WILMINGTON AVENUE
POST OFFICE BOX 6254
CARSON, CALIFORNIA 90749
310-537-3700 • 800-421-1244
FAX:310-537-3927
WWW:multiquip.com
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 5
Download from Www.Somanuals.com. All Manuals Search And Download.
STOW CP-20H — SPECIFICATIONS/DIMENSIONS (PUMP)
Table 1. Specifications (Pump)
Model
CP-20H
Type
Centrifugal Pump
2x2 in. (51x51 cm.)
Suction & Discharge Size
Maximum Pumping
Capacity
158 gallons/minute
(598 liters/minute)
Pump
HP (kw)
4 (3.0)
0.66 (2.5)
Fuel Capacity Gal. (L)
Max. Head
98 ft. (30 meters)
19 x 14 x 16 in.
(48 X 35 X 40 cm.)
Dimension
(L x W x H)
48.5 lbs. (22 Kg.)
Dry Net Weight
Figure 1. STOW CP-20H Dimensions
PAGE 6 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
STOW CP-20H — SPECIFICATIONS/DIMENSIONS (ENGINE)
Table 2. Specifications (Engine)
Model
HONDA GX120K1PX2
Air-cooled 4 stroke, Single
Cylinder, OHV, Horizontal
Shaft Gasoline Engine
Type
2.4 in. x 1.7 in.
(60 mm x 42 mm)
Bore X Stroke
Displacement
Max Output
119 cc (7.2 cu-in)
4.0 H.P./3600 R.P.M.
Engine
Approx. 0.66 U.S. gallons
(2.5 liters)
Fuel Tank Capacity
Unleaded Automobile
Gasoline
Fuel
Lube Oil Capacity
.60 liters (0.63 qts)
Centrifugal Fly-weight Type
Recoil Start
Speed Control
Method
Starting Method
11.7 x 13.4 x 12.5 in.
(480 x 350 x 400 mm)
Dimension
(L x W x H)
Dry
Net Weight
28.7 lbs (13 Kg.)
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 7
Download from Www.Somanuals.com. All Manuals Search And Download.
STOW CP-20H — SAFETY MESSAGE ALERT SYMBOLS
FORYOUR SAFETY ANDTHE SAFETY OF OTHERS!
HAZARD SYMBOLS
Safety precautions should be followed at all times when operating
this equipment. Failure to read and understand the Safety
Messages and Operating Instructions could result in injury to
yourself and others.
Lethal Exhaust Gases
Engine exhaust gases contain poisonous
This Owner's Manual has been
developed to provide complete
instructions for the safe and
efficient operation of the STOW
Model CP-20H Centrifugal
Pump. Refer to the engine
manufacturers instructions for data
carbon monoxide. This gas is colorless and
odorless, and can cause death if inhaled.
NEVER operate this equipment in a confined
area or enclosed structure that does not
provide ample free flow air.
relative to its safe operation.
Before using these pumps, ensure that the operating
individual has read and understands all instructions in this
manual.
Explosive Fuel
GASOLINE is extremely flammable, and its
vapors can cause an explosion if ignited. DO
NOT start the engine near spilled fuel or
combustible fluids. DO NOT fill the fuel tank
while the engine is running or hot. DO NOT
overfill tank, since spilled fuel could ignite if it
comes into contact with hot engine parts or
sparks from the ignition system. Store fuel in
approved containers, in well-ventilated areas
and away from sparks and flames. NEVER
SAFETY MESSAGE ALERT SYMBOLS
The three (3) Safety Messages shown below will inform you
about potential hazards that could injure you or others. The
Safety Messages specifically address the level of exposure to
the operator, and are preceded by one of three words: DANGER,
WARNING, or CAUTION.
Burn Hazards
DANGER: You WILL be KILLED or
SERIOUSLY injured if you do not follow
Engine components can generate extreme heat.
To prevent burns, DO NOT touch these areas
while the engine is running or immediately after
operations. Never operate the engine with heat
shields or heat guards removed.
WARNING: You CAN be KILLED or
SERIOUSLY injured if you do not follow
directions.
Rotating Parts
CAUTION: You CAN be injured if you
do not follow directions.
NEVER operate equipment with covers, or
guards removed. Keep fingers, hands, hair and
clothing away from all moving parts to prevent
injury.
Potential hazards associated with the STOW CP-20H Centrifugal
Pump operation will be referenced with Hazard Symbols which
appear throughout this manual, and will be referenced in
conjunction with Safety Message Alert Symbols.
PAGE 8 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
STOW CP-20H — SAFETY MESSAGE ALERT SYMBOLS
Accidental Starting
Respiratory Hazard
ALWAYS place the engine ON/OFF switch in
the OFF position when the pump is not in use.
ALWAYS wear approved respiratory
protection.
Equipment Damage Messages
Sight and Hearing hazard
Other important messages are provided throughout this manual
to help prevent damage to your pump, other property, or the
surrounding environment.
ALWAYS wear approved eye and hearing
protection.
This pump, other property, or the
surrounding environment could be
damaged if you do not follow
instructions.
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 9
Download from Www.Somanuals.com. All Manuals Search And Download.
STOW CP-20H — RULES FOR SAFE OPERATION
■
NEVERtouchthehotexhaustmanifold,
muffler or cylinder.Allow these parts to
cool before servicing engine or pump.
DANGER:
Failure to follow instructions in this manual may
lead to serious injury or even death! This
equipment is to be operated by trained and
qualified personnel only!This equipment is for
industrial use only.
The following safety guidelines should always be used when
operating the centrifugal pump:
■
■
HighTemperatures – Allow the engine to cool before adding
fuel or performing service and maintenance functions. Contact
with hot components can cause serious burns.
GENERAL SAFETY
■
DO NOT operate or service this equipment before
readingthisentiremanual.
The engine of this pump requires an adequate free flow of
cooling air. NEVER! operate the pump in any enclosed or
narrow area where free flow of the air is restricted. If the air
flow is restricted it will cause
■
■
This equipment should not be operated by
persons under 18 years of age.
serious damage to the
pump or engine and may
cause injury to people and
property. Remember the
NEVER operate this equipment without proper
protective clothing, shatterproof glasses, steel-
toed boots and other protective devices required
by the job.
pump's engine gives off
DEADLY gases.
■
■
NEVER operate this equipment when not feeling
well due to fatigue, illness or taking medicine.
■
■
ALWAYS refuel in a well-ventilated area, away from sparks
and open flames.
NEVER operate this equipment under the
influence or drugs or alcohol.
ALWAYS use extreme caution when working with flammable
liquids. When refueling, stop the engine and allow it to cool.
DO NOT smoke around or near the machine. Fire or explosion
could result from fuel vapors, or if fuel is spilled on a hot
engine.
■
■
■
Whenever necessary, replace nameplate, operation and safety
decals when they become difficult read.
■
NEVER operate the pump in an explosive
atmosphere or near combustible
materials. An explosion or fire could result
causing severe bodily harm or even
death.
ALWAYS check the machine for loosened threads or bolts
before starting.
ALWAYS wear proper respiratory (mask) hearing and eye
protection equipment when operating the pump.
■
■
Topping-off to filler port is dangerous, as it tends to spill fuel.
Refer to the Engine Owner's Manual for engine technical
questions or information.
■
■
NEVER use accessories or attachments, which are not
recommended by Multiquip for this equipment. Damage to
the equipment and/or injury to user may result.
Manufacturer does not assume responsibility for any accident
due to equipment modifications.
PAGE 10 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
STOW CP-20H — RULES FOR SAFE OPERATION
■
■
■
■
NEVER Run engine without air cleaner. Severe engine
■
High Temperatures – Always stop engine and allow the
engine to cool before adding fuel, oil or performing service
and maintenance functions. Contact with hot components can
cause serious burns.
damage may occur.
ALWAYS read, understand, and follow procedures in
Operator’s Manual before attempting to operate equipment.
■
NEVER disconnect any "emergency or safety devices".
These devices are intended for operator safety. Disconnection
of these devices can cause severe injury, bodily harm or even
death! Disconnection of any of these devices will void all
warranties.
ALWAYS be sure the operator is familiar with proper safety
precautions and operation techniques before using pump.
ALWAYS store equipment properly when it is not being used.
Equipment should be stored in a clean, dry location out of the
reach of children.
Maintenance Safety
■
■
■
■
NEVER leave the pump unattended, turn off engine when
unattended.
NEVER lubricate components or attempt service on a running
machine.
Unauthorized equipment modifications will void all
warranties.
■
ALWAYS allow the machine a proper amount of time to cool
before servicing.
NEVER pump volatile, explosive, flammable or low flash
point fluids.These fluids could ignite or explode.
■
■
Keep the machinery in proper running condition.
Fix damage to the machine immediately and always replace
broken parts, or missing decals.
■
■
NEVER operate the pump in an explosive atmosphere.
Before starting the pump, check that the clean-out cover is
securely fasten.
■
■
■
Dispose of hazardous waste properly.Examples of potentially
hazardous waste are used motor oil, fuel and fuel filters.
■
■
ALWAYS ensure pump is on level ground before use.
DO NOT use food or plastic containers to dispose of
hazardous waste.
Become familiar with the components of the pump before
operating.
DO NOT pour waste, oil or fuel directly onto the ground,
down a drain or into any water source.
■
■
ALWAYS replace any worn or damaged warning decals.
NEVER pump corrosive chemicals or water containing toxic
substances. These fluids could create serious health and
environmental hazards. Contact local authorities for
assistance.
Emergencies
■
ALWAYS know the location of the
nearest fire extinguisher.
■
NEVER open the priming plug when pump is hot. Hot water
inside could be pressurized much like the radiator of an
automobile. Allow pump to cool to the touch before loosening
plug.
■
■
ALWAYS know the location of the nearest
first aid kit.
■
■
NEVER open the pump housing during operation or start the
pump with the clean-out cover removed.The rotating impeller
inside the pump can cut or sever objects caught in it.
In emergencies always know the location of the
nearest phone or keep a phone on the job site.
Also know the phone numbers of the nearest
ambulance, doctor and fire department. This
information will be invaluable in the case of an
emergency.
NEVER block or restrict flow from discharge hose. Remove
kinks from discharge line before starting pump. Operation
with a blocked discharge line can cause water inside pump
to overheat.
■
■
ALWAYS fill the pump casing with water before starting the
engine. Failure to maintain water inside the pump housing
will cause severe damage to the pump.
In winter drain water from pump housing to prevent freezing.
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 11
Download from Www.Somanuals.com. All Manuals Search And Download.
STOW CP-20H — GENERAL INFORMATION
Elevation
APPLICATION
Higher elevations will effect the performance of the pump. Due to
less atmospheric pressure at higher altitudes, pumps DO NOT
have the priming ability that they have at sea level. This is due to
the “thinner air” or lack of oxygen at higher altitudes.
The STOW Model CP-20H Centrifugal Pump is designed to
be used for de-watering applications. Both the suction and
discharge ports on the STOW CP-20H pump use a 2-inch
diameter opening, which allows the pump to pump at a rate of
approximately 158 gallons/minute (gpm) or 598 liters/minute
(lpm).
A general rule of thumb is that for every 1,000 feet of elevation
above sea level a pump will lose one foot of priming ability.
Centrifugal or self priming pumps are designed to purge air from
the suction line and create a partial vacuum in the pump body.
The reduced atmospheric pressure inside the pump allows water
to flow through the suction line and into the pump body. The
centrifugal force created by the rotating impeller pressurizes the
water and expels it from the pump.
For example, in Flagstaff, Arizona where the elevation is
approximately 7,000 feet, the pump would have a suction lift of
only 18 feet rather than the 25 feet at sea level. Table 3 shows
suction lift at various elevations.
Table 3. Suction Lift at Various Elevations
Power Plant
Altitude
Suction Lift in Feet (Meters)
Feet (Meters)
This trash pump is powered by an 4.0 horsepower air cooled 4-
stroke, single cylinder HONDA GX-120 gasoline engine that
incorporates a low "Oil Alert Feature"
Sea Level
10.0 (3.048) 15.0 (4.572) 20.0 (6.096) 25.0 (7.620)
8.80 (2.680) 13.2 (4.023) 17.6 (5.364) 22.0 (6.705)
7.80 (2.377) 11.7 (3.566) 15.6 (4.754) 19.5 (5.943)
6.90 (2.103) 10.4 (3.169) 13.8 (4.206) 17.3 (5.273)
6.20 (1.889) 9.30 (2.834) 12.4 (3.779) 15.5 (4.724)
2,000 (610)
4,000 (1,219)
6,000 (1,829)
8,000 (2,438)
Oil Alert Feature
In the event of low oil or no oil, the HONDA GX-120 engine has
a built-in oil alarm engine shut-down feature. In the event the oil
level is low the engine will automatically shut-down.
10,000 (3,048) 5.70 (1.737) 8.60 (2.621) 11.4 (3.474) 14.3 (4.358)
Standard Centrifugal Pump
Standard centrifugal pumps provide an economical choice for
general purpose dewatering. These types of pumps should only
be used in clear water applications (agricultural, industrial,
residential) as they have a limited soild handling capability of
only 10% by volume.
Table 4 shows percentage drops in performance as elevation
increases.
Table 4. Performance Loss at Various
Elevations
Suction Lift
This pump is intended to be used for dewatering applications
and is capable of suction lifts up to 25 feet at sea level. For
optimal suction lift performance keep the suction hose or line as
short as possible. In general always place the pump as close to
the water as possible.
Altitude
Feet (Meters
Discharge Flow
Discharge Head
Sea Level
100%
97%
95%
93%
91%
88%
100%
95%
91%
87%
83%
78%
Pump Support
2,000 (610)
The pump should always be placed on solid stationary ground
in a level position.
4,000 (1,219)
6,000 (1,829)
8,000 (2,438)
10,000 (3,048)
NEVER place the pump on soft soil. The suction hose or pipe
connection should always be checked for tightness and leaks. A
small suction leak in the hose or fittings could prevent the pump
from priming.
PAGE 12 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
STOW CP-20H — PUMP COMPONENTS
Figure 2 shows a typical application using the STOW Model CP-20H centrifugal pump. Please note that this pump is intended for
the removal of clean water. This type of pump should only be used for clear water (no large debris) applications as it has a limited
solid handling capability of only 10% by volume. DO NOT set strainer on bottom of water bed. Placing the strainer above the water
bed will prevent the pump from drawing in excessive amounts of sand and foreign debris.
Figure 2. STOW CP-20H Pump A
1. Pump – The STOW Model CP-20H is 2-inch centrifugal 6. Suction Port – Connect a 2-inch inlet hose to this port.
pump used in general purpose de-watering applications.
Pump should only be used for clear water applications
such as agricultural, industrial and residential.
Use two worm clamps to secure the hose.
7. Suction Hose – Connect this flexible rubber hose to the
suction port on the pump. Make sure that the hose lays flat
and is not kinked. Use only recommended type suction
hose. Contact Multiquip parts department for ordering
information
2. Fill Cap – Prior to operation, the pump casing should be
filled with water.Remove this cap to add water to the pump.
After the initial prime, a sufficient amount of water will be
retained in the casing so that the operator will not need to
re-prime later.
8. Clean-out Cover Handles –To gain access to the pump's
clean-out area, grip both handles, then pull to remove cover.
Make sure both locking knobs have been released before
attempting to remove clean-out cover.
If the casing is dry or has insufficient water, the pump will
have difficulty in priming which could lead to premature
mechanical seal wear thus causing damage to the pump.
9. Drain Plug – Remove this plug to drain water from the
3. Discharge Port – Connect a 2-inch discharge hose to this
pump.
port.
10. Clean-out Cover – Remove cover to gain access to the
4. Worm Clamp – Used to secure the hose to the inlet and
outlet ports on the pump. Use two clamps to secure the
hose on the inlet side of the pump.
clean-out area.
11. Locking Knobs– Turn both knobs clockwise to secure
clean-out cover, turn counter-clockwise to release cover.
5. Discharge Hose – Connect this flexible rubber hose to
the discharge port on the pump. Make sure that the hose
lays flat and is not kinked. Use only recommended type
discharge hose. Contact Multiquip parts department for
ordering information.
12. Strainer – Always attach a strainer to bottom side of the
suction hose to prevent large objects and debris from
entering the pump. Strainer should be positioned so that it
will remain completely under water.Running the pump with
the strainer above water for long periods can damage pump.
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 13
Download from Www.Somanuals.com. All Manuals Search And Download.
STOW CP-20H — BASIC ENGINE
Figure 3. Engine Controls and Components
INITIAL SERVICING
The engine (Figure 3) must be checked for proper lubrication and
filled with fuel prior to operation. Refer to the manufacturers engine
manual for instructions & details of operation and servicing. The
engine shown above is a HONDA engine, operation for other
types of engines may vary somewhat.
6. Choke Lever – Used in the starting of a cold engine, or in
cold weather conditions. The choke enriches the fuel
mixture.
7. Air Cleaner – Prevents dirt and other debris from entering
the fuel system. Remove wing-nut on top of air filter
cannister to gain access to filter element.
1. Fuel Filler Cap – Remove this cap to add unleaded
gasoline to the fuel tank. Make sure cap is tightened
securely. DO NOT over fill.
Operating the engine without an
air filter, with a damaged air filter,
or a filter in need of replacement
DANGER
will allow dirt to enter the engine,
causing rapid engine wear.
Adding fuel to the tank should be done only when
the engine is stopped and has had an opportunity to
cool down. In the event of a fuel spill, DO NOT attempt to start the
engine until the fuel residue has been completely wiped up, and the
area surrounding the engine is dry.
8. Spark Plug – Provides spark to the ignition system. Set
spark plug gap to 0.6 - 0.7 mm (0.028 - 0.031 inch) Clean
spark plug once a week.
9. Muffler – Used to reduce noise and emissions.
2. Throttle Lever – Used to adjust engine RPM speed (lever
advanced forward SLOW, lever back toward operator
FAST).
WARNING
3. Engine ON/OFF Switch – ON position permits engine
Engine components can generate extreme heat.
To prevent burns, DO NOT touch these areas
starting, OFF position stops engine operations.
4. Recoil Starter (pull rope) – Manual-starting method. Pull
the starter grip until resistance is felt, then pull briskly and
smoothly.
while the engine is running or immediately after operating. NEVER
operate the engine with the muffler removed.
10. Fuel Tank – Holds unleaded gasoline. For additional
5. FuelValve Lever – OPEN to let fuel flow, CLOSE to stop
information refer to engine owner's manual.
the flow of fuel.
PAGE 14 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
STOW CP-20H — PRE-INSPECTION (ENGINE)
3. Insertandremovethedipstickwithoutscrewingitintothefiller
neck. Check the oil level shown on the dipstick.
CAUTION
NEVER operate the pump
in a confined area or
enclosed area structure that
does not provide ample free
flow of air.
4. If the oil level is low (Figure 5), fill to the edge of the oil filler
holewiththerecommendedoiltype(Table5).Maximum oil
capacity is 1.16 quarts (1.1 liters)
ALWAYS wear approved eye and hearing
protection before operating the pump.
Before Starting
Figure 5. Engine Oil Dipstick (Oil Level)
Table 5. Oil Type
1.
Read safety instructions at the
beginning of manual.
2.
Clean the pump, removing dirt and
dust, particularly the engine
cooling air inlet, carburetor and air
cleaner.
Season
Summer
Spring/Fall
Winter
Temperature
25°C or Higher
25°C~10°C
Oil Type
SAE 10W-30
SAE 10W-30/20
SAE 10W-10
3.
4.
5.
Check the air filter for dirt and dust. If air filter is dirty, replace
air filter with a new one as required.
0°C or Lower
Check carburetor for external dirt and dust. Clean with dry
compressed air.
Check fastening nuts and bolts for tightness.
Explosive Fuel
DANGER
Engine Oil Check
1.
To check the engine oil level, place the pump on secure
level ground with the engine stopped.
Motor fuels are highly flammable and can be
dangerous if mishandled. DO NOT smoke
while refueling. DO NOT attempt to refuel the
pump if the engine is hot! or running.
2.
Remove the filler dipstick from the engine oil filler hole
(Figure 4) and wipe clean.
Fuel Check
1. Remove the gasoline cap located on top of fuel tank.
2. Visually inspect to see if the fuel level is low. If fuel is low,
replenish with unleaded fuel.
3. When refueling, be sure to use a strainer for filtration. DO
NOT top-off fuel. Wipe up any spilled fuel immediately!
Figure 4. Engine Oil Dipstick (Removal)
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 15
Download from Www.Somanuals.com. All Manuals Search And Download.
STOW CP-20H — PRE-SETUP (PUMP)
Before Starting
Suction and discharge hoses are
NOTE
1. Read safety instructions at the
beginning of manual.
available from Multiquip. Contact
your nearest dealer for more
information.
2. Place pump as near to water as
possible,onafirmflat,levelsurface.
5. The discharge hose is usually a collapsible (thin-walled)
hose, however if a thin-walled discharge hose is not avail-
able, a rigid suction hose can be substituted in its place.
3. Toprimepump,removefillcap(Figure2)andfillpumpcasing
with water.If the pump casing is not filled with water before
starting, it will not begin pumping.
6. Make sure the suction strainer (Figure 2) is clean and
securely attached to the water end of the suction hose. The
strainer is designed to protect the pump by preventing large
objects from being pulled into the pump.
CAUTION :
Pump casing must be filled with water
before using pump. Otherwise pump will
not be able to begin pumping.
CAUTION :
The strainer should be positioned so it will
remain completely under water. Running the
pump with the strainer above water for long
periods can damage the pump.
WARNING :
DO NOT open fill cap if pump is hot!Water
inside may be under pressure.
CAUTION :
DO NOT pump flammable fluids, corrosive
chemicals or fluids containing toxic substances.
These fluids can create potentially dangerous
health and environmental hazards. Contact
local authorities for assistance.
4. Checkforleaksbetweenpumpandengine.Ifwaterisleaking
between the pump and engine housing, the seal inside the
pumpmaybewornordamaged.Continued operationofthe
pumpisnot recommended.Furtherusageofthe pumpunder
theseconditionsmaycauseseverewaterdamagetoengine.
Hoses and Clamps
CAUTION :
This pump uses a water-cooled mechanical
1. Check that all hoses are securely attached to the pump.
Make certain suction hose (Figure 2) does not have any air
leakage.Tighten hose clamps and couplings as required.
seal to prevent water from seeping into the
engine. The passage of water through the
pump casing lubricates the seal and prevents
it from overheating. NEVER! operate the pump
without water in the casing as this will cause
damage to the mechanical seal.
2. Itisrecommendedthat 2 clampsbeusedwhensecuringthe
suction hose to the inlet side (suction) of the pump.
3. Remember suction hoses must be rigid enough not to
collapse when the pump is in operation.
4. Check that the discharge hose (Figure 2) is not restricted.
Place hose so that it lays as straight as it is possible on the
ground. Remove any twists or sharp bends from hose which
may block the flow of water.
PAGE 16 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
STOW CP-20H — INITIAL START-UP (ENGINE)
3. Place the choke lever (Figure 8) in the "OPEN " position if
CAUTION :
starting a cold engine.
DO NOT attempt to operate the pump until the Safety, General
Information and Inspection sections of this manual have been
read and thoroughly understood.
This section is intended to assist the operator with the initial
start-up of the trash pump. It is extremely important that this
section be read carefully before attempting to use the pump in
the field.
Starting the Engine (HONDA engine)
Figure 8. Engine Choke Lever (Open)
1. Place the engine fuel valve lever (Figure 6) to the "ON"
position.
4. Placethechokelever(Figure 9)inthe"CLOSED"position
if starting a warm engine or the temperature is warm.
Figure 6. Engine FuelValve Lever (ON Position)
2. Move the throttle lever (Figure 7) away from the slow
position, about 1/3 of the way toward the fast position.
Figure 9. Engine Choke Lever (Closed)
5. Place the engine ON/OFF switch (Figure 10) in the "ON "
position.
Figure 7. Throttle Lever (1/3 Start Position)
Figure 10. Engine ON/OFF Switch (ON Position)
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 17
Download from Www.Somanuals.com. All Manuals Search And Download.
STOW CP-20H — INITIAL START-UP (ENGINE)
6. Grasp the starter grip (Figure 11) and slowly pull it out.The
CAUTION :
resistancebecomesthehardestatacertainposition,corre-
spondingtothecompressionpoint.Pullthestartergripbriskly
andsmoothlyforstarting.
ALWAYS run engine at full speed while
pumping.
Stopping The Engine
Normal Shutdown
1. Movethethrottlelever tothe“IDLE“position (Figure14)and
run the engine for three minutes at low speed.
Figure 11. Starter Grip
7. If the engine has started, slowly return the choke lever
(Figure12)tothe“CLOSED“position.Iftheenginehasnot
started repeat steps 1 through 6.
Figure 14.Throttle Lever (Idle)
2. Aftertheenginecools,turntheengineON/OFFswitchtothe
“OFF” position (Figure 15).
Figure 12. Choke Lever (Closed)
8. Beforethepumpisplacedintooperation,runtheenginefor
severalminutes. Checkfor fuelleaks,andnoisesthatwould
associate with a lose component.
Figure 15. Engine ON/OFF Switch (OFF)
3. Place the fuel shut-off lever (Figure 16) in the “OFF“
9. To begin pumping, place the throttle lever (Figure 13) in the
position.
"RUN" position.
Figure 16. Fuel Valve Lever (OFF)
Emergency Showdown
1. Move the throttle lever quickly to the “IDLE“ position, and
Figure 13. Throttle Lever (Run)
place the engine ON/OFF switch in the “OFF“ position.
PAGE 18 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTE PAGE
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 19
Download from Www.Somanuals.com. All Manuals Search And Download.
STOW CP-20H — MAINTENANCE (PUMP)
Pump Vacuum Test
Adjusting Impeller Clearance
1. If it is necessary to replace impeller or volute, be sure
clearance between impeller and volute is adjusted
CAUTION :
DO NOT attempt to start the engine unless
the pump has previously been primed with
correctly.
2. The impeller should be as close to the volute as possible
without rubbing against it. Clearance is adjusted by
adding or removing shims from behind the impeller.
water. Severe pump damage will occur if
pump has not been primed.
To perform the pump vacuum test do the following:
3. Check clearance between impeller and insert by slowly
pulling starter rope to turn impeller. Remove spark plug
to make it easier to turn impeller.
1. Remove the pump fill cap (Figure 2), and fill the pump
with water.
2. Start the engine as outlined in the initial start-up section,
and wait for the pump to begin pumping.
It is important not to remove too
many shims or the clearance
between the impeller and volute
will become too wide and pump
performance will be reduced.
Remember as the impeller wear
3. As shown in Figure 17 (next page), place a water hose
inside the discharge opening of the pump, and turn on
the water.This flow of water into the discharge opening
will prevent the pump from running dry.
down, additional shims may be required to maintain the
clearance between the impeller and insert.
4. Place the Pump Vacuum Tester (P/N 7000030) over
the pump suction (inlet) opening (Figure 17) with the
vacuum gauge facing upwards. It may be necessary to
apply a small amount of water around the rubber seal of
the vacuum tester to make a good suction fit.
4. Check the impeller every six months for wear, and for
clearance between the impeller face and the volute. Also
check the shaft seal for wear, as well as the shaft sleeve.
Pump Cleaning
5. Check and make sure that there are no air leaks between
the vacuum tester and the inlet port on the pump. If air
leaks are present reseat vacuum tester.
After pumping water containing large amounts of dirt and
debris, perform the following:
6. Run the pump for a few minutes while monitoring the
vacuum gauge. If the gauge indicates a reading between
-25 and -20 in. Hg. (inches of mercury) then it can be
assumed that the pump is working correctly.
1. Remove the drain plug from the pump housing (Figure 2)
and drain any water left in the pump.
2. Loosen the two locking hand knobs (turn counter-
clockwise) and remove clean-out cover.
25 in. Hg (inches of mercury)
translates into 25 feet of lift at sea
level.
3. Clean and remove dirt, debris from pump casing.Inspect
impeller and volute for wear. Replace any damaged or
worn parts.
7. If the vacuum tester gauge indicates a reading CAUTION :
below -20 in. Hg, it can then be assumed that the pump
is not functioning correctly, and corrective action needs
to be taken.
The impeller may develop sharp edges.
Use extreme care when cleaning around
the impeller to prevent being cut.
6. To test the flapper valve, shut down the engine. The
vacuum tester should remain attached to the pump
suction inlet port by vacuum. This indicates the pump's
flapper valve is seating properly to hold water in the
suction hose when the engine is stopped.This prevents
backflow and allows for faster priming when the engine
is restarted.
PAGE 20 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
STOW CP-20H — MAINTENANCE (PUMP)
may vary
ee Tables 3
Figure 17. Pump VacuumTester
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 21
Download from Www.Somanuals.com. All Manuals Search And Download.
STOW CP-20H — MAINTENANCE (ENGINE)
Engine Maintenance
Perform engine maintenance procedures as referenced by
Table 6 below:
Table 6. Engine Maintenance Schedule
FIRST
EVERY
EVERY
EVERY
YEAR
OR
EVERY
2 YEARS
OR
MONTH 3 MONTHS 6 MONTHS
OR
DESCRIPTION (3)
OPERATION
BEFORE
OR
OR
10 HRS.
25 HRS.
50 HRS.
100 HRS.
200 HRS.
CHECK
CHANGE
CHECK
X
Engine Oil
X
X
X
Air Cleaner
All Nuts & Bolts
Spark Plug
CHANGE
X (1)
Re-tighten If
Necessary
CHECK-CLEAN
REPLACE
CHECK
X
X
X
Cooling Fins
Spark Arrester
Fuel Tank
CLEAN
X
X
CLEAN
Fuel Filter
CHECK
X
Idle Speed
CHECK-ADJUST
CHECK-ADJUST
CHECK
X (2)
Valve Clearance
Fuel lines
X (2)
Every 2 years (replace if necessary) (2)
(1) Service more frequently when used in DUSTY areas.
(2) These items should be serviced by your servic dealer, unless you have the proper tools and are mechanically
proficient. Refer to the HONDA shop Manual for service procedures
(3) For commercial use, log hours of operation to determine proper maintenance intervals.
Reference manufacturer engine
manual for specific servicing
instructions.
PAGE 22 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
STOW CP-20H — MAINTENANCE (ENGINE)
DANGER :
Maintenance
Performtheenginemaintenanceproceduresasindicatedbelow:
DO NOT use gasoline as a cleaning solvent,
because that would create a risk of fire or
explosion.
DAILY
■
Thoroughly remove dirt and oil from the engine and control
area.Clean or replace the air cleaner elements as necessary.
Check and retighten all fasteners as necessary. Check the
spring box and bellows for oil leaks. Repair or replace as
needed.
ENGINEAIRCLEANER
1. Remove the air cleaner cover and foam filter element as
shown in Figure 20.
WEEKLY
■
Remove the fuel filter cap and clean the inside of the fuel
tank.
2. Tap the paper filter element (Figure 20) several times on a
hard surface to remove dirt, or blow compressed air [not
exceeding 30 psi (207 kPa, 2.1 kgf/cm2)] through the filter
elementfromtheaircleanercaseside.NEVER brushoffdirt.
Brushingwillforcedirtintothefibers.Replacethepaperfilter
element if it is excessively dirty.
■
■
Remove or clean the filter at the bottom of the tank.
Remove and clean the spark plug (Figure 18), then adjust
the spark gap to 0.028 ~0.031 inch (0.6~0.7 mm).This unit
has electronic ignition, which requires no adjustments.
3. Cleanfoamelementinwarm,soapywaterornonflammable
solvent. Rinseanddrythoroughly. Diptheelementinclean
engineoilandcompletelysqueezeouttheexcessoilfromthe
element before installing.
Figure 18. Spark Plug Gap
ENGINEOIL
1. Drain the engine oil when the oil is warm as shown in
Figure 19.
2. Remove the oil drain bolt and sealing washer and allow
the oil to drain into a suitable container.
3. Replace engine oil with recommended type oil as listed
in Table 5. Engine oil capacity is 1.16 quarts (1.1 liters).
DO NOT overfill.
4. Install drain bolt with sealing washer and tighten se-
curely.
Figure 20. Engine Air Cleaner
Figure 19. Engine Oil (Draining)
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 23
Download from Www.Somanuals.com. All Manuals Search And Download.
STOW CP-20H — PREPARATION FOR LONG -TERM STORAGE
Pump Storage
For storage of the pump for over 30 days, the following is
required:
z
z
Drain the fuel tank completely.
Run the engine until the fuel in the injection system is
completely consumed.
z
Completely drain used oil from the engine crankcase
and fill with fresh clean oil, then follow the procedures
described in the engine manual for engine storage.
z
z
Remove the drain plug from the pump and drain out any
water from left in the housing.
Remove the pump cover and clean inside of pump
housing. Coat inside of pump housing with a light film of
oil to reduce corrosion. A spray can of oil works well for
this application.
z
z
z
Cover suction and discharge ports with duct tape to
prevent any foreign matter from falling into pump.
Cover pump and engine with plastic covering or
equivalent and store in a clean, dry place.
To protect the water cooled-seals, place one-half pint of
lubricating oil (new or used) through the discharge opening
on the pump and crank the engine several times. This
will prevent excessive corrosion and also keep the
mechanical seal lubricated.
PAGE 24 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTE PAGE
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 25
Download from Www.Somanuals.com. All Manuals Search And Download.
STOW CP-20H — TROUBLESHOOTING (ENGINE)
TABLE 7. ENGINE TROUBLESHOOTING
SYMPTOM
Difficult to start
POSSIBLE PROBLEM
SOLUTION
Ignition plug being bridge?
Carbon deposit at ignition?
Check ignition system.
Clean or replace ignition.
Replace insulators.
Fuel is available but spark plug
will not ignite. (Power available
at high tension cable).
Short circuit due to defective
insulators?
Improper spark gap?
Set spark plug gap to the correct gap.
Check stop switch circuit. Replace stop switch if defective.
Replace ignition coil.
Short circuit at stop switch?
Ignition coil defective?
Fuel is available but spark plug
will not ignite. (Power NOT
available at high tension cable).
Muffler clogged with carbon
deposits?
Clean or replace muffler.
Mixed fuel quality is
inadequate?
Check fuel to oil mixture.
Fuel is available and spark plug
ignites (compression normal).
Fuel in use inadequate (water,
dust)?
Flush fuel sytem and replace with fresh fuel.
Air Cleaner clogged?
Defective cylinder head gasket?
Cylinder worn?
Clean or replace air cleaner.
Tighten cylinder head bolts or replace head gasket.
Replace cylinder.
Fuel is available and spark plug
ignites (compression low ).
Spark plug loose?
Tighen spark plug.
Operation not satisfactory
Air cleaner clogged?
Air in fuel line?
Clean or replace air cleaner.
Bleed (remove air) from fuel line.
Not enough power available
(compression normal, no miss-
firing).
Fuel level in carbureator float
chamber improper?
Adjust carbureator float
Carbon deposits in cylinder?
Ignition coil defective?
Clean or replace cylinder
Flush fuel sytem and replace with fresh fuel.
Replace ignition wires, clean ignition.
Flush fuel sytem and replace with fresh fuel.
Not enough power available
(compression normal, miss-
firing).
Ignition plug often shorts?
Fuel in use inadequate (water,
dust)?
Excessive carbon depostion in
combustion chamber?
Clean or replace crankcase.
Clean or replace muffler.
Engine overheats.
Exhaust or muffler clogged with
carbon.
Spark plug heat value incorrect? Replace spark plug with correct type spark plug.
PAGE 26 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
STOW CP-20H — TROUBLESHOOTING (ENGINE/PUMP)
TABLE 7. ENGINE TROUBLESHOOTING (Continued)
SYMPTOM
POSSIBLE PROBLEM
SOLUTION
Operation not satisfactory
Governor adjustment improper?
Governor spring defective?
Fuel flow erratic?
Adjust governor to correct lever.
Clean or replace ignition.
Check fuel line.
Rotational speed fluctuates.
Air taken in through suction
line?
Check suction line.
Dust in rotating part?
Spring spring failure?
Clean recoil starter assembly.
Replace sprial spring.
Recoil starter not working
properly.
TABLE 8. PUMP TROUBLESHOOTING
SYMPTOM
POSSIBLE PROBLEM
SOLUTION
Not enough priming water in the housing?
Engine speed too low?
Add water.
Increase throttle.
Clean strainer.
Strainner plugged?
Suction hose damaged?
Replace or repair hose, and clamps
Check that fittings are tight and properly sealed.
Move pump closer to water.
Air leak at suction port?
Pump does not take on water.
Pump is located too high above water line?
Debris collecting in pump housing?
Clean pump housing.
Adjust clearance by adding shims or replace impeller.
Min. .006" - Max. .020"
Too much distance between impeller and volute.
Water leaking out weep hole between pump and Check condition of mechanical seal and gaskets,
engine?
between pump end and engine housing.
Engine speed too low?
Increase throttle speed.
Pump takes in water, little or no Suction strainer partially plugged?
Clean strainer.
discharge.
Impeller/Volute worn?
Adjust clearance by adding shims or replace
impeller/volute
Tighten, replace or add clamp. (Keep extra seals on
pump)
Fittings/clamps are not sealed properly?
Suction hose leaks at inlet.
Hose diameter is too large?
Use smaller diameter hose or replace hose.
Check pressure, add additional clamp.
Check hose.
Pressure too high?
Discharge does not stay on
coupling.
Hose kinked or end blocked?
Impeller jammed or blocked?
Open pump cover and clean dirt and debris from
inside housing.
Impeller does not turn: pump is
hard to start.
Adjust clearance by removing shim from behind
impeller.
Impeller and volute binding?
Defective engine?
See Engine Owner's Manual.
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 27
Download from Www.Somanuals.com. All Manuals Search And Download.
STOW CP-20H — EXPLANATION OF CODE IN REMARKS COLUMN
How to read the marks and remarks used in this parts book.
Items Found In the“Remarks” Column
he contents of this catalog are
ubject to change without notice.
Serial Numbers-Where indicated, this indicates a serial number
range (inclusive) where a particular part is used.
Model Number-Where indicated, this shows that the
corresponding part is utilized only with this specific model number
or model number variant.
Items Found In the “Items Number” Column
All parts with same symbol in the number column, , #, +, %,
*
or <, belong to the same assembly or kit.
Note: If more than one of the same reference number is listed,
the last one listed indicates newest (or latest) part available.
If more than one of the same
reference number is listed, the
last one listed indicates newest (or
latest) part avaliable.
PAGE 28 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
STOW CP-20H — SUGGESTED SPARE PARTS
STOW CP-20H CENTRIFUGAL PUMP
1TO 3 UNITS WITH
HONDA GX120K1PX2 ENGINE
Qty.
P/N
Description
2 ............ KITCP20H ............ KIT, PUMP, MECHANICAL SEAL, O-RINGS
2 ............ 0631211101 .......... DRAIN CAP, FLOODING
2 ............ 0480350300 .......... O-RING FLOODING DRAIN CAP
2 ............ 1211350350 .......... CHECKVALVE
2 ............ 0482201200 .......... O-RING, CHECKVALVE
1 ............ 1864000030 .......... IMPELLER
3 ............ 17210ZE0505 ....... ELEMENT AIR CLEANER DUAL
3 ............ 9807956846 .......... SPARK PLUG
1 ............ 17620ZH7023 ....... CAP, FUEL WITH GASKET
1 ............ 28462ZH8003 ....... ROPE STARTER
Part number on this Suggested
Spare Parts List may super cede
or replace the P/N shown in the
text pages of this book.
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 29
Download from Www.Somanuals.com. All Manuals Search And Download.
STOW CP-20H — PUMP ASSY.
PUMP ASSY.
PAGE 30 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
STOW CP-20H — PUMP ASSY.
PUMP ASSY.
NO.
1
2
3
4
PART NO.
PART NAME
CASING
CASING COVER
DELIVERY ELBOW
VOLUTE CASING
NIPPLE
QTY. REMARKS
9249100010
1877100020
9246100090
1877100130
07904320200005
1864000030
0808112320
0489242100
0489241780
0482201200
0482200720
0481310550
0480350300
1211350350
1211390610
0631211101
0852831600
0852851600
0181050820
0181051025
0141090510
0401450050
0105050840
0209150080
0209150060
0191150520
0451250080
0723322030
92942140100018
0742303050
GX120K1PX2
KITCP20H
1
1
1
1
1
1
5
6
7
8
IMPELLER
MECHANICAL SEAL........................ 1 .......REPLACES 0803112320
O-RING, CASING
O-RING, VOLUTE CASING
O-RING, CHECK VALVE
O-RING, DELIVERY ELBOW
O-RING, NIPPLE
*
1
1
1
1
2
*
9
*
10
11
12
13
*
O-RING, FLOODING / DRAIN CAP 2
14
15
16
CHECK VALVE
PACKING, CASING COVER
CAP, FLOODING / DRAIN
ADJUST LINER
ADJUST LINER
BOLT SET W/ SPRING WASHER
BOLT SET W/ SPRING WASHER
SCREW
WASHER
BOLT
FLANGE NUT
FLANGE NUT
1
1
2
1
1
4
4
2
2
4
4
4
4
4
4
1
1
1
*
17
*
17
*
19
20
21
22
23
24
25
26
27
28
29
31
32
33
BOLT
SPRINGWASHER
CUSION RUBBER
PIPE FRAME
STRAINER
ENGINE
KIT, PUMP STOW ............................ 1 .......INCLUDES ITEMS W/
*
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 31
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — AIR CLEANER (DUAL) ASSY.
AIR CLEANER (DUAL) ASSY.
PAGE 32 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — AIR CLEANER (DUAL) ASSY.
AIR CLEANER (DUAL) ASSY.
NO.
1
2
3
*
4
PART NO.
PART NAME
QTY.
REMARKS
16271ZE1000
17210ZE0505
17218ZE0505
17230ZE0820
17232891000
17238ZE0010
17239ZE1000
17410ZE0030
90325044000
957010602000
9405006000
GASKET, ELBOW
1
ELEMENT, AIR CLEANER (DUAL) ................... 1.............INCLUDES ITEMS W/
FILTER, OUTER
COVER, AIR CLEANER (DUAL)
GROMMET, AIR CLEANER
COLLAR, AIR CLEANER
COLLAR B, AIR CLEANER
ELBOW, AIR CLEANER ................................... 1.............INCLUDES ITEMS W/
WINGNUT, TOOL BOX SETTING
BOLT, FLANGE 6X20
*
1
1
1
2
1
5
*
7
8
9
#
#
#
12
13
14
2
1
2
NUT, FLANGE 6MM
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 33
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — CAMSHAFT ASSY.
CAMSHAFT ASSY.
PAGE 34 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — CAMSHAFT ASSY.
CAMSHAFT ASSY.
NO.
1
2
3
4
PART NO.
PART NAME
QTY.
REMARKS
14100ZE0812
14410ZE0010
14431ZE1000
14441ZE1010
14451ZE1013
14568ZE1000
14711ZF0010
14751ZF1000
14771ZE1000
14773ZE1000
14781ZE1000
14791ZE0010
90012ZE0010
90206ZE1000
CAMSHAFT ASSEMBLY.................................. 1.............INCLUDES ITEMS W/
*
ROD, PUSH
ARM, VALVE ROCKER
LIFTER, VALVE
PIVOT, ROCKER ARM
SPRING, WEIGHT RETURN
VALVE, IN.
2
2
2
2
1
1
2
1
1
1
1
2
2
5
6
*
7
9
10
11
12
13
14
15
SPRING, VALVE
RETAINER, IN. VALVE SPRING
RETAINER, EX. VALVE SPRING
ROTATOR, VALVE
PLATE, PUSH ROD GUIDE
BOLT, PIVOT 8MM
NUT, PIVOT ADJ.
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 35
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — CARBURETOR ASSY.
CARBURETOR ASSY.
PAGE 36 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — CARBURETOR ASSY.
CARBURETOR ASSY.
NO.
PART NO.
PART NAME
QTY. REMARKS
1
*
2
*
3
*
4
*
5
*
6
*
7
*
8
*
9
16010ZE1812
16011ZE0005
16013ZE0005
16015ZE1811
16016ZH7W01
16024ZE1811
16028ZE0005
16044ZE0005
16100ZH8W51
16124ZE0005
16166ZH7W50
16173001004
16211ZE1000
16212ZH7800
16220ZE1020
16221ZH8801
16610ZE1000
16953ZE1812
16954ZE1811
16956ZE1811
16957ZE1812
16967ZE0811
93500030080G
9430520122
GASKET SET
1
1
1
1
1
1
1
1
VALVE SET, FLOAT
FLOAT SET
CHAMBER SET, FLOAT
SCREW SET
SCREW SET, DRAIN
SCREW SET B
CHOKE SET
CARBURETOR ASSY. (BE65B B) ................ 1 ...... INCLUDES ITEMS W/
SCREW, THROTTLE STOP
NOZZLE, MAIN
*
10
1
1
1
1
1
1
1
*
11
*
12
*
O-RING
13
INSULATOR, CARBURETOR
GASKET, INSULATOR
SPACER, CARBURETOR
GASKET, CARBURETOR
LEVER, CHOKE (STD) ................................ 1 ...... INCLUDES ITEMS W/
LEVER, VALVE
PLATE, LEVER SETTING
SPRING, VALVE LEVER
GASKET, VALVE
CUP, FUEL STRAINER
SCREW, PAN (3 X 6)
PIN, SPRING (2 X 12)
JET, MAIN (#55) OPTIONAL
JET, MAIN (#58) OPTIONAL
JET, MAIN (#60)
14
15
16
17
#
18
1
1
1
1
1
2
1
1
1
1
1
*
19
*
20
*
21
*
22
*
23
*
24
25
25
25
26
#
99101ZH80550
99101ZH80580
99101ZH80600
99204ZE00350
*
*
JET, SET, PILOT (#35)
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 37
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — CONTROL ASSY.
CONTROL ASSY.
PAGE 38 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — CONTROL ASSY.
CONTROL ASSY.
NO.
1
4
5
6
PART NO.
PART NAME
QTY.
REMARKS
16500ZH7000
16551ZE0010
16555ZE0000
16561ZE0020
16562ZE0020
16571ZH7000
16574ZE1000
16575ZH8000
16578ZE1000
16580ZH7000
16584883300
90013883000
90015ZE5010
90022888010
90114SA0000
93500050250H
9405006000
CONTROL ASSEMBLY .................................... 1.............INCLUDES ITEMS W/
*
ARM, GOVERNOR
ROD, GOVERNOR
SPRING, GOVERNOR
SPRING,THROTTLE RETURN
LEVER, CONTROL
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
7
8
9
*
SPRING, LEVER
*
10
WASHER, CONTROL LEVER
SPACER, CONTROL LEVER
BASE, CONTROL
SPRING, CONTROL ADJUSTING
BOLT, FLANGE 6X12 (CT200)
BOLT, GOVERNOR ARM
BOLT, FLANGE 6X20 (CT200)
NUT, SELF- LOCK 6MM
SCREW, PAN 5X25
*
12
*
13
*
15
*
18
19
20
21
*
24
*
26
NUT, FLANGE 6MM
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 39
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — CRANKCASE COVER ASSY.
CRANKCASE COVER ASSY.
PAGE 40 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — CRANKCASE COVER ASSY.
CRANKCASE COVER ASSY.
NO.
1
2
3
4
PART NO.
PART NAME
COVER ASSEMBLY, CRANKCASE (U- TYPE).........1 ............. INCLUDES ITEMS W/
GASKET, CASE COVER
CAP ASSEMBLY, OIL FILLER ..................................1 ............. INCLUDES ITEMS W/
CAP ASSEMBLY, OIL FILLER ..................................1 ............. INCLUDES ITEMS W/
QTY.
REMARKS
11300ZE0640
11381ZH7800
15600ZE1003
15600ZG4003
15625ZE1003
15625ZE1003
90015883000
91001878003
91203ZE0003
9430108140
%
1
*
#
7
GASKET, OIL FILLER CAP
GASKET, OIL FILLER CAP
BOLT, FLANGE 6X28
BEARING, RADIAL BALL
OIL SEAL 22X41X6
1
1
7
1
1
2
*
8#
9
10
11
12
%
%
PIN A, DOWEL 8X14
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 41
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — CRANKSHAFT ASSY.
CRANKSHAFT ASSY.
PAGE 42 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — CRANKSHAFT ASSY.
CRANKSHAFT ASSY.
NO.
6
PART NO.
13310ZE0650
PART NAME
CRANKSHAFT, P-TYPE
QTY.
1
REMARKS
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 43
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — CYLINDER BARREL ASSY.
CYLINDER BARREL ASSY.
PAGE 44 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — CYLINDER BARREL ASSY.
CYLINDER BARREL ASSY.
NO.
2
3
PART NO.
PART NAME
QTY.
REMARKS
12000ZH7415
15510ZE1033
16510ZE1000
16511ZE1000
16512ZE1000
16513ZE1000
16531ZE1000
16541ZE1000
90131ZE1000
90451ZE1000
90601ZE1000
90602ZE1000
91001878003
91202ZE6003
91353671003
9405010000
CYLINDER ASSEMBLY, 811 (OIL ALERT)............ 1.............. INCLUDES ITEMS W/
*
#
SWITCH ASSEMBLY, OIL LEVEL
GOVERNOR ASSEMBLLY .................................... 1.............. INCLUDES ITEMS W/
1
4
5#
6#
7#
8
9
WEIGHT, GOVERNOR
HOLDER, GOVERNORWEIGHT
PIN, GOVERNOR WEIGHT
SLIDER, GOVERNOR
SHAFT, GOVERNOR ARM
BOLT, DRAIN PLUG
WASHER, THRUST 6MM
WASHER, DRAIN PLUG 10.2MM
CLIP, GOVERNOR HOLDER
BEARING, RADIAL BALL 62/22
OIL SEAL 22X35X6
O- RING 13.5X1.5 (ARAI)
NUT, FLANGE 10MM
2
1
2
1
1
2
1
2
1
1
1
1
1
2
1
2
10
11
12
13
14
15
16
17
18
19
20
*
*
9410106800
9425108000
957010601200
WASHER, PLAIN 6MM
PIN, LOCK 8MM
BOLT, FLANGE 6X12
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 45
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — CYLINDER HEAD ASSY.
CYLINDER HEAD ASSY.
PAGE 46 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — CYLINDER HEAD ASSY.
CYLINDER HEAD ASSY.
NO.
PART NO.
PART NAME
QTY.
REMARKS
1
12210ZH7000
12204ZE1306
12205ZE1315
12216ZE5300
12251ZH7800
12310ZE1000
12310ZE1010
12391ZE1000
15721ZH8000
90013883000
90043ZE1020
90047ZE1000
9430110160
CYLINDER HEAD ..................................................1.............. INCLUDES ITEMS W/
*
#
2
*
3
*
GUIDE, VALVE (OS) OPTIONAL
GUIDE, EX. VALVE (OS) OPTIONAL ................... 1.............. INCLUDES ITEMS W/
CLIP, VALVE GUIDE
GASKET, CYLINDER HEAD
COVER, HEAD
COVER, HEAD
GASKET, CYLINDER HEAD COVER
TUBE, BREATHER
BOLT, FLANGE 6X12 (CT200)
BOLT, STUD 6X109
BOLT, STUD 8X32
1
4
5
6
6
7
8
9
#
1
1
1
1
1
1
4
2
2
2
4
1
1
*
10
11
12
14
15
15
PIN, A, DOWEL 10X16
BOLT, FLANGE 8X55
SPARK PLUG W16EPR- U (DENSO), OPT.
SPARK PLUG BPR6ES, (NGK)
957230805500
9807955855
9807956846
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 47
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — FAN COVER ASSY.
FAN COVER ASSY.
PAGE 48 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — FAN COVER ASSY.
FAN COVER ASSY.
NO.
1
2
3
4
5
6
7
8
PART NO.
PART NAME
QTY.
REMARKS
11347371300
19610ZE0000ZE
19612ZH7810
90601ZH7013
19630ZH7000
32197ZH8003
36100ZH7003
36101ZE1010
90013883000
90022888010
34150ZH7003
957010600800
GROMMET, ADJUSTING COVER
COVER, FAN *NH1* BLACK
PLATE, SIDE (OIL ALERT)
CLIP, HARNESS
1
1
1
1
1
1
1
1
6
1
1
1
SHROUD
SUB- HARNESS
SWITCH ASSEMBLY, ENGINE STOP
WIRE, STOP SWITCH 370MM
BOLT, FLANGE 6X12 (CT200)
BOLT, FLANGE 6X12 (CT200)
ALERT UNIT, OIL
9
10
11
13
BOLT, FLANGE 6X8
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 49
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — FLYWHEEL ASSY.
FLYWHEEL ASSY.
PAGE 50 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — FLYWHEEL ASSY.
FLYWHEEL ASSY.
NO.
1
2
4
5
PART NO.
PART NAME
KEY, SPECIAL WOODRUFF 25X18
FAN, COOLING
PULLEY, STARTER
FLYWHEEL
NUT, SPECIAL 14MM
QTY.
REMARKS
13331357000
19511ZE0000
28451ZH8003
31100ZE0010
90201878003
1
1
1
1
1
7
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 51
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — FUELTANK ASSY.
FUEL TANK ASSY.
PAGE 52 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — FUELTANK ASSY.
FUEL TANK ASSY.
NO.
1
2
3
5
PART NO.
PART NAME
RUBBER, SUPPORTER 107MM
JOINT, FUEL TANK
TANK, FUEL *NH1* (BLACK)
CAP, FUEL FILLER................................................ 1.............. INCLUDES ITEMS W/
GASKET, FUEL FILLER CAP
O- RING 13.5X1.5 (ARAI)
NUT, FLANGE 6MM
BULK HOSE, FUEL (4.5X3000) (4.5X140)
CLIP, TUBE (B8)
QTY.
REMARKS
16854ZH8000
16955ZE1000
17510ZE0020ZD
17620ZH7023
17631ZH7003
91353671003
9405006000
1
1
1
*
6
1
1
2
1
2
1
*
11
12
13
14
15
950014500360M
9500202080
90004ZH7003
BOLT, FLANGE 6X29
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 53
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — IGNITION COIL ASSY.
IGNITION COIL ASSY.
PAGE 54 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — IGNITION COIL ASSY.
IGNITION COIL ASSY.
NO.
1
2
PART NO.
PART NAME
QTY.
REMARKS
30500ZE1033
30700ZE1013
90121952000
COIL ASSEMBLY, IGNITION
CAP ASSEMBLY, NOISE SUPPRESSOR
BOLT, FLANGE 6X25
1
1
2
8
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 55
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — MUFFLER ASSY.
MUFFLER ASSY.
PAGE 56 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — MUFFLER ASSY.
MUFFLER ASSY.
NO.
1
3
7
10
13
PART NO.
PART NAME
QTY.
REMARKS
18310ZF1000
18320ZF1H01
18381ZH8800
90050ZE1000
94001080000S
MUFFLER
1
1
1
4
2
PROTECTOR, MUFFLER
GASKET, MUFFLER
SCREW, TAPPING 5X8
NUT, HEX. 8MM
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 57
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — PISTON ASSY.
PISTON ASSY.
PAGE 58 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — PISTON ASSY.
PISTON ASSY.
NO.
1
1
1
1
PART NO.
PART NAME
QTY.
REMARKS
13010ZK7V01
13011ZK7V01
13012ZK7V01
13013ZK7V01
RING SET, PISTON (STANDARD)
RING SET, PISTON (OS 0.25), OPTIONAL
RING SET, PISTON (OS 0.50), OPTIONAL
RING SET, PISTON (0.75), OPTIONAL
1
1
1
1 .......... USE FROM ENGINE
...................................................................................................... S/N 3284617
2
2
2
2
3
4
4
13101ZH7000
13102ZH7000
13103ZH7000
13104ZH7000
13111ZE0000
132A0ZE0000
13200ZE0000
90001ZE1000
90551ZE0000
PISTON, STANDARD
1
1
1
1
1
PISTON, OS 0.25 (OPTIONAL)
PISTON, OS 0.50 (OPTIONAL
PISTON, 0.75 (OPTIONAL)
PIN, PISTON
ROD ASSY., CONNECTING (UNDERSIZE) OPTIONAL .... 1 .......... INCLUDES ITEMS W/
ROD ASSEMBLY, CONNECTING ................................... 1 .......... INCLUDES ITEMS W/
*
*
5
*
6
BOLT, CONNECTING ROD
CLIP, PISTON PIN 13MM
2
2
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 59
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — RECOILSTARTER ASSY.
RECOIL STARTER ASSY.
PAGE 60 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — RECOILSTARTER ASSY.
RECOIL STARTER ASSY.
NO.
PART NO.
PART NAME
QTY.
REMARKS
1
28400ZH8013ZB
28410ZH8003ZB
28420ZH8013
28422ZH8013
28433ZH8003
28441ZH8003
28442ZH8003
28443ZH8003
28461ZH8003
28462ZH8003
90003ZH8003
90008ZE2003
STARTER ASSY., RECOIL *NH1* (BLACK) .......... 1.............. INCLUDES ITEMS W/
*
2
CASE, RECOIL STARTER
REEL, RECOIL STARTER
RATCHET, STARTER
GUIDE, RATCHET
SPRING, FRICTION
SPRING, RECOIL STARTER
SPRING, RETURN
KNOB, RECOIL STARTER
ROPE, RECOIL STARTER
SCREW, SETTING
1
1
2
1
1
1
2
1
1
1
3
*
3
*
4
*
5
*
6
*
7
*
8
*
9
*
10
*
11
*
12
BOLT, FLANGE 6X10
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 61
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — GASKET KIT ASSY.
NO ARTWORK AVALIBLE
PAGE 62 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE — GASKET KIT ASSY.
GASKET KIT ASSY.
NO.
PART NO.
PART NAME
QTY.
REMARKS
1
06111ZH7405
11381ZH7800
12251ZH7800
12391ZE1000
16212ZH7800
16221ZH8801
18381ZH8800
GASKET KIT ......................................................... 1.............. INCLUDES ITEMS W/
*
2
*
3
*
4
*
5
*
6
*
7
*
GASKET, CASE COVER
GASKET, CYLINDER HEAD
GASKET, CYLINDER HEAD COVER
GASKET, INSULATOR
GASKET, CARBURETOR
GASKET, MUFFLER
1
1
1
1
1
1
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 63
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE —LABELS ASSY.
LABELS ASSY.
PAGE 64 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
HONDA GX120K1PX2 ENGINE —LABELS ASSY.
LABELS ASSY.
NO.
1
3
4
6
PART NO.
PART NAME
QTY.
REMARKS
87521ZH7020
87522ZH9000
87528ZE1810
87532ZH8810
EMBLEM
1
1
1
1
LABEL, CAUTION
MARK, CHOKE
MARK, OIL ALERT (E)
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 65
Download from Www.Somanuals.com. All Manuals Search And Download.
Effective: October 1, 2002
TERMS AND CONDITIONS OF SALE — PARTS
PAYMENT TERMS
5. Partsmustbeinnewandresalablecon- Multiquipreservestherighttoquoteandsell
dition,intheoriginalMultiquippackage(if directtoGovernmentagencies,andtoOriginal
any), and with Multiquip part numbers Equipment Manufacturer accounts who use
Terms of payment for parts are net 10 days.
FREIGHTPOLICY
clearlymarked.
our products as integral parts of their own
products.
All parts orders will be shipped collect or
prepaidwiththechargesaddedtotheinvoice.
All shipments are F.O.B. point of origin.
Multiquip’sresponsibilityceaseswhenasigned
manifesthasbeenobtainedfromthecarrier,
andanyclaimforshortageordamagemustbe
settledbetweentheconsigneeandthecarrier.
6. Thefollowingitemsarenotreturnable:
SPECIALEXPEDITINGSERVICE
a. Obsolete parts. (If an item is in the
price book and shows as being re- A$35.00surchargewillbeaddedtotheinvoice
placedbyanotheritem,itisobsolete.) forspecialhandlingincludingbusshipments,
insuredparcelpostorincaseswhereMultiquip
mustpersonallydeliverthepartstothecarrier.
(such as gaskets, seals, “O” rings,
b. Any parts with a limited shelf life
andotherrubberparts)thatwerepur- LIMITATIONSOFSELLER’SLIABILITY
MINIMUMORDER
chasedmorethansixmonthspriorto
thereturndate.
Multiquip shall not be liable hereunder for
damagesinexcessofthepurchasepriceofthe
The minimum charge for orders from Mul-
tiquipis$15.00net.Customerswillbeasked
for instructions regarding handling of orders
notmeetingthisrequirement.
c. Anylineitemwithanextendeddealer item with respect to which damages are
netpriceoflessthan$5.00.
claimed, and in no event shall Multiquip be
liable for loss of profit or good will or for any
otherspecial,consequentialorincidentaldam-
ages.
d. Special order items.
RETURNEDGOODSPOLICY
e. Electricalcomponents.
f. Paint,chemicals,andlubricants.
g. Decalsandpaperproducts.
h. Itemspurchasedinkits.
Returnshipmentswillbeacceptedandcredit
willbeallowed,subjecttothefollowingprovi-
sions:
LIMITATIONOFWARRANTIES
Nowarranties,expressorimplied,aremade
in connection with the sale of parts or trade
accessoriesnorastoanyenginenotmanufac-
tured by Multiquip. Such warranties made in
connectionwiththesaleofnew,completeunits
are made exclusively by a statement of war-
rantypackagedwithsuchunits,andMultiquip
neitherassumesnorauthorizesanypersonto
assume for it any other obligation or liability
whatever in connection with the sale of its
products.Apartfromsuchwrittenstatementof
warranty, there are no warranties, express,
impliedorstatutory,whichextendbeyondthe
descriptionoftheproductsonthefacehereof.
1. AReturnedMaterialAuthorizationmust
be approved by Multiquip prior to ship-
ment.
7. Thesenderwillbenotifiedofanymaterial
receivedthatisnotacceptable.
2. ToobtainaReturnMaterialAuthorization,
alistmustbeprovidedtoMultiquipParts
Salesthatdefinesitemnumbers,quanti-
ties, and descriptions of the items to be
returned.
8. Suchmaterialwillbeheldforfiveworking
days from notification, pending instruc-
tions.Ifareplyisnotreceivedwithinfive
days,thematerialwillbereturnedtothe
senderathisexpense.
a. Thepartsnumbersanddescriptions
must match the current parts price
list.
9. Creditonreturnedpartswillbeissuedat
dealer net price at time of the original
purchase,lessa15%restockingcharge.
b. The list must be typed or computer
generated.
10. In cases where an item is accepted, for
which the original purchase document
can not be determined, the price will be
basedonthelistpricethatwaseffective
twelvemonthspriortotheRMAdate.
c. The list must state the reason(s) for
thereturn.
d. The list must reference the sales
order(s)orinvoice(s)underwhichthe
itemswereoriginallypurchased.
11. Credit issued will be applied to future
purchasesonly.
e. The list must include the name and
phonenumberofthepersonrequest-
ingtheRMA.
PRICINGANDREBATES
Prices are subject to change without prior
notice.Pricechangesareeffectiveonaspe-
cificdateandallordersreceivedonorafterthat
datewillbebilledattherevisedprice.Rebates
3. AcopyoftheReturnMaterialAuthoriza-
tionmustaccompanythereturnshipment.
4. Freight is at the sender’s expense. All forpricedeclinesandaddedchargesforprice
partsmustbereturnedfreightprepaidto increaseswillnotbemadeforstockonhand
Multiquip’sdesignatedreceivingpoint.
atthetimeofanypricechange.
PAGE 66 — STOW CP-20H CENTRIFUGAL PUMP — PARTS MANUAL — REV. #0 (05/30/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTE PAGE
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 67
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION AND PARTS MANUAL
HERE'S HOW TO GET HELP
PLEASE HAVE THE MODEL AND SERIAL
NUMBER ON-HANDWHEN CALLING
PARTS DEPARTMENT
800-427-1244 or 310-537-3700
FAX: 800-672-7877 or 310-637-3284
SERVICE DEPARTMENT
800-421-1244
FAX: 310- 537-4259
TECHNICAL ASSISTANCE
800-478-1244
FAX: 310- 631-5032
WARRANTY DEPARTMENT
888-661-4279, or 310-661-4279
FAX: 310- 537-1173
STOWCONSTRUCTIONEQUIPMENT
A DIVISION OF MULTIQUIP INC.
POST OFFICE BOX 6254
PARTS DEPARTMENT:
800-427-1244
FAX: 800-672-7877
SERVICE DEPARTMENT/TECHNICAL ASSISTANCE:
800-478-1244
CARSON, CA 90749
310-537-3700 • 888-252-STOW [888-252-7869]
FAX:310-537-1986 • FAX:800-556-1986
E-MAIL: [email protected] • WWW: stowmfg.com
FAX:310-631-5032
Download from Www.Somanuals.com. All Manuals Search And Download.
|