Sterling Dehumidifier STT 300 User Manual

Operating Instructions  
Dehumidified Air Dryer  
STT 300  
with Simens control unit  
Sterling Material Processing  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STT 300  
Sterling Material Processing  
5200 West Clinton Ave.  
Milwaukee, WI 53223  
Telephone: (414) 354-0970  
Fax: (414) 354-6421  
Service department:  
Telephone: (800) 423-3183  
Edition: 05/02  
Order confirmation number: _ _ _ _ _ _ _ _ _ _ _  
These operating instructions are for:*  
(* Please fill in personally)  
Serial number:  
Built in:  
Date of delivery:  
Number of delivery:  
Date of commissioning:  
Location:  
Group of machines:  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
STT 300  
Sterling Material Processing retains all rights to change the information in these  
operating instructions at any time without notice.  
We assume no liability for any errors or direct or indirect damage resulting in con-  
text with these operating instructions.  
Copying, translation or publication in any form except for personal use of pur-  
chaser requires approval from Sterling Material Processing.  
All rights reserved.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
STT 300  
TABLE OF CONTENTS  
1. General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1  
1.1. Warnings and symbols. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2  
1.2. Explanations and information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3  
1.3. Legal basis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3  
1.4. Fields of applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3  
1.5. Notes on Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3  
2. Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1  
2.1. For your safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2  
2.2. For the safety of the devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5  
3. Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1  
3.1. Control system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2  
3.1.1. Key assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2  
3.1.2. Flow chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3  
3.2. Switching on the dryer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4  
3.2.1. Operation statuses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4  
3.3. Viewing the software-version. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5  
3.4. Passwords. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5  
3.5. Basic parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7  
3.5.1. Turning the devices on/off. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7  
3.5.2. Entering dryer values. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9  
3.5.3. Entering hopper values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11  
3.5.4. Observing processing status. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13  
3.5.5. Setting date and time. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-14  
3.5.6. Viewing/changing language and contrast . . . . . . . . . . . . . . . . . . . 3-15  
3.5.7. Changing parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-16  
3.5.8. Setting the timer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17  
3.6. Starting continuous operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18  
3.7. Viewing system runtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-19  
3.8. Switching the dryer off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-20  
4. Error and error correction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
STT 300  
5. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1  
5.1. Maintenance intervals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3  
5.2. Cleaning/renewing the air filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4  
5.3. Tensioning the V-belts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-8  
5.4. Disposing of the drying agent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-10  
5.5. Servicing the accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-10  
5.6. Changing the battery of the control system . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-11  
5.6.1. Resetting the control values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-13  
6. Functional description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1  
6.1. Dryer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2  
6.2. Drying hopper (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3  
6.3. Return air cooler (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4  
6.4. Hopper heaters (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5  
6.5. Automatic motor flaps (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5  
6.6. Connection to a pneumatic conveying system (optional) . . . . . . . . . . . . . . . . . 6-5  
7. Transport, Assembly and Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1  
7.1. Transport and Packing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2  
7.2. Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4  
7.3. Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4  
8. Assembly instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1  
8.1. Mounting of the suction device for regeneration exhaust air . . . . . . . . . . . . . . 8-2  
8.2. Connection of the air coolers (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2  
8.3. Electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3  
9. Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
STT 300  
10. Spare parts list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-1  
10.1. Switching Cabinet and Operating Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-4  
11. Electrical manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-1  
o Connection diagram no.: _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _  
o Currently not available; will be delivered at a later date!  
12. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-1  
o Entering values on the OP 7 / 17  
o Flap control with Fuzzy-Logic  
o Elektror High-pressure blower with frequency converter operation  
o Elektror High-pressure blower  
o _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _  
o _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dehumidified Air Dryer  
1. General Information  
These operating instructions are addressed to all users of the device.  
These operating instructions must be used by every person charged with  
work on the unit.  
»
General Information 1-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Dehumidified Air Dryer  
1.1. Warnings and symbols  
The following warnings and symbols are used in these operating instructions:  
This symbol indicates danger to life! Fatal or serious injury is possible if the  
corresponding instructions, regulations or warnings are not observed.  
»
L
This symbol indicates that serious injury is possible if the corresponding  
instructions, regulations or warnings are not observed.  
This symbol indicates that extensive damage to equipment is possible if  
the corresponding instructions, regulations or warnings are not obser-  
ved.  
F
This symbol indicates information important for becoming familiar with  
the equipment, i.e. technical correlations.  
&
This symbol indicates that a technical term is explained at this point.  
$
General Information 1-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Dehumidified Air Dryer  
1.2. Explanations and information  
Various terms and designations are used in these operating instructions to ensure clarity. There-  
fore please note that the terms used in the text stand for the corresponding explanations listed be-  
low.  
Equipment  
”Equipment” can mean an individual unit, a machine or an installation.  
Operating personnel  
The ”operating personnel” are persons operating the equipment on their own responsibility or ac-  
cording to instructions.  
Operator  
The ”operator” oftheequipment(production manager, foreman, etc.)is theperson responsible for  
allproductionsequences. Theoperatorinstructstheoperatingpersonnelofwhatistobedone.  
Operating instructions  
The ”operating instructions” describe the interaction of the equipment, production sequences or  
methods. The operating instructions must be compiled by the operator of the equipment.  
Equipment foreman  
When several operating personnel work on one machine, the ”equipment foreman” coordinates  
the sequences. The equipment foreman must be appointed by the operator.  
Trained personnel  
”Trained personnel” are persons who, due to their training, are authorized to carry out the required  
work.  
1.3. Legal basis  
See “Manufacturer’s Certificate” resp. “Certificate of Conformity”.  
1.4. Fields of applications  
For the drying of thermoplastic granules and regrind before processing in order to remove all re-  
maining moisture from the granules both inside and out, independent of climate or ambient air  
conditions.  
1.5. Notes on Usage  
Experienced operators can begin directly with the chapter on “Start-up” if the unit has been pro-  
perly installed.  
If the unit has not been installed yet, observe the instructions in the chapter on “Assembly Instruc-  
tions” and “Transport, Assembly and Storage”.  
General Information 1-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Dehumidified Air Dryer  
2. Safety instructions  
These safety instructions apply to all persons within the range of action of the  
equipment.  
»
Please inform all persons within the range of action of the equipment of the  
direct and indirect hazards connected with the equipment.  
These operating instructions are to be used by all persons assigned activi-  
ties connected with the equipment.  
Knowledge of the English language is prerequisite.  
Ensure in each case that the operating personnel are familiar with the opera-  
ting instructions and the function of the equipment.  
Safety instructions 2-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Dehumidified Air Dryer  
2.1. For your safety  
General  
The operating personnel of this equipment must be at least 16 years old.  
Please read these operating instructions carefully before taking into operation for the first time.  
Contact us should questions arise. This avoids injury and damage to equipment!  
These operating instructions must be kept available at all times at the place of operation of the  
equipment. Improper operation results in danger of accidents!  
Please note that, for reasons of clarity, not all conceivable cases regarding operation or mainten-  
ance of the equipment can be covered in these operating instructions.  
Please observe all safety instructions and warnings on the equipment. This avoids injury and da-  
mage to equipment!  
All work on the equipment is to be carried out by persons whose qualifications are specified in the  
pertaining chapters of the operating instructions. Improper operation results in danger of acci-  
dents!  
The proper working clothes are to be worn during any work on the equipment. This avoids injury!  
The local regulations and requirements pertaining to this equipment must be observed.  
Disconnect electrical components from the mains supply before work is carried out on these com-  
ponents Caution: Danger to life through electrical shock!  
Compile detailed operating instructions based on these Operating instructions for the sequence  
of procedures to be carried out on this equipment. Improper operation results in danger of acci-  
dents!  
Observe that the control system is still under voltage even when the main switch is switched off.  
Caution: Danger to life through electrical shock!  
Safety instructions 2-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Dehumidified Air Dryer  
Assembly  
Compare the connected loads with those of the mains supply. Danger of injury through electrical  
shock!  
When using lifting gear, please observe the pertaining regulations. Caution: Danger of accidents!  
Do not modify, add other equipment or change the design of the equipment without the approval  
of the manufacturer. Caution: Danger of accidents!  
Attachments not supplied by Sterlingmust be manufactured in accordance with safety regulation  
EN 294. Danger of accidents!  
The equipment may only be operated when all the associated components are properly connec-  
ted up and in accordance with the relevant regulations. This avoids injury and damage to equip-  
ment!  
Operate the device only if all its components are grounded. Danger: accident through electrical  
shock!  
Please note for installation that the equipment is top-heavy. Danger exists that it may topple over!  
Take care that the device is not standing on the mains cable. This will prevent danger to people  
and material!  
Operation  
Appoint an equipment foreman to be responsible for the equipment.  
Ensure that the operating personnel are provided detailed instruction in the operation of the  
equipment. Improper operation results in danger of accidents!  
When the main switch is switched off for reasons pertaining to safety, it must be secured against  
unauthorized activation. Caution: Danger of accidents!  
Repair work may be carried out by trained personnel only. Caution: Danger of accidents!  
Never operate the equipment when partially dismantled! Danger! Limbs may be caught in machi-  
nery! Electric shock!  
In case of malfunction, shut down the equipment immediately. Have malfunctions corrected im-  
mediately. Danger of accidents!  
The machine is intended only for the drying of granulated plastics. Any other or additional use is  
contrary to specifications.  
This equipment is not suitable for food processing.  
The safety instructions of the connected machines must be followed.  
Please note that sound levels exceeding 85 db(A) may in the long term damage your health. Use  
the appropriate ear muffs. This avoids impairment of hearing!  
Please note that the drying cells, drying hoppers and air pipings grow hot during use. Avoid tou-  
ching any of these parts! Danger: Injury through burns!  
Never operate the dryer without side panels. Danger: Limbs may be caught in machinery! Injury  
through burns!  
Safety instructions 2-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dehumidified Air Dryer  
When drying plastics which emit gases dangerous for human health, take care that the regenera-  
tion exhaust air is disposed of without polluting the environment. This will prevent danger to peo-  
ple and material!  
Operate the dryer only if there is at least one drying hopper operating. This will prevent damage of  
material!  
Maintenance  
Before starting maintenance work, appoint a supervisor.  
Inform the responsible personnel before maintenance work on the system is started. Caution:  
Danger of accidents!  
Disconnect the equipment from mains supply before starting maintenance procedures to ensure  
that it cannot be switched on unintentionally. Caution: Danger of accidents!  
All pipes, hoses and screwed connections should be checked regularly for leaks and damage.  
Any faults which arise should be corrected immediately. Danger of accidents!  
Depressurise all compressed air piping before starting maintenance work. Danger of accidents!  
The air filters should only be cleaned/replaced when the the main switch is off and the blower has  
stopped. This avoids injury and damage to equipment!  
Any maintenance work on the equipment should only be started when the the main switch is off  
and the blower has stopped. This avoids injury and damage to equipment!  
Check the v-belts of the blower only when the main switch is switched off and the blowers have  
stopped. Caution: Danger of accidents!  
Open drying hoppers only if they are completely empty. Danger of accidents!  
Never open drying hoppers while the device is in operation. Danger: Iinjury through burns!  
Open drying hoppers only if they have been cooled down sufficiently. Danger: Injury through  
burns!  
Before starting maintenance work wait until the drying cells, drying hoppers and air pipings have  
been cooled down sufficiently. Avoid touching any of these parts! Danger: Injury through burns!  
Remove any granules remaining on the ground. Danger of accidents!  
Arrest the wheels after installation if the dryer is mounted on a movable frame. This will prevent  
danger to people and material!  
Safety instructions 2-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dehumidified Air Dryer  
2.2. For the safety of the devices  
Never change settings without carefully assessing the consequences.  
Use only original Sterlingspare parts.  
Observe the maintenance instructions.  
Keep a record of all maintenance works and repairs.  
Please note that electronic components can be damaged by static discharge.  
Before initial operation and in regular intervals, make sure that no electrical connections are loo-  
se.  
Never readjust sensors without exactly knowing their functions.  
Please ensure that the permitted storage temperature lies between -20 and +55 °C  
(-4 to +131 °F).  
Please ensure that the permitted operation temperature lies between 0 and +45 °C  
(32 to +113 °F).  
Check the direction of rotation of the blowers after the electrical connections have been made  
(see rotational direction arrow).  
Clean the drying hoppers before the first filling.  
Note the instructions of the material manufacturer for the maximum drying temperature.  
Note the drying instructions of the material manufacturer.  
Take care that the drying hoppers are always completely filled and that the retention period is re-  
spected if continual removal is taking place.  
Note that too large amounts taken from the drying hopper lead to insufficient drying of the materi-  
al.  
Close the air stop valves of drying hoppers which are empty or have not been used.  
Note down all data which you have entered into the control system.  
The password is to be entrusted to authorised personnel only.  
Please note that the temperature of the dryer heating system must always be set lower than that of  
the supplementary heaters.  
When you dispose of drying agents, observe all official rules.  
Note that drying cells are replaced or refilled by Sterling only if they are empty.  
The material level may not fall below 40 % in the drying hopper, when material is continuously re-  
moved from the drying hopper, but no material is continuously fed into the drying hopper (batch  
drying). Close the throttle valves.  
Read the operating manuals of the connected devices.  
Safety instructions 2-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STT 300  
3. Start-up  
Version: 64.10-8266GB01 05/02  
This chapter is directed at the operators of the equipment.  
This chapter assumes general skills in dealing with drying systems and SPS  
(PLC) control units.  
»
This chapter assumes that the functional description has been read and un-  
derstood.  
It should be ensured in each and every case that the operators have the rele-  
vant skills.  
Note down all set values of the control system.  
Make sure that the cooling appliance is connected to the mains socket in  
the electrical cabinet (if present, optional).  
F
Make sure that any condensate penetrating from the cooling appliance  
(optional) does not get inside the dryer or the control box.  
If the inside temperature of the switch cabinet is above +50°C(122°F),  
the dryer is switched off after 30 minutes if it is operated with a cooling ap-  
pliance (optional).  
&
Start-up 3-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STT 300  
3.1. Control system  
The control system is switched on at the main switch. The control system is operated via a  
”selection window” and the keyboard of the operator panel.  
The facility’s control system is factory-programmed. Nevertheless, you have to set specific  
values (basic parameters) which are dependent on the processed material, for instance.  
The values entered are stored in the control system and remain so, even after the unit is switched  
off or in the event of a power cut. All messages are displayed in plain text.  
In describing this start-up, we have assumed that the various sub-menus are selected from the  
”table of contents”.  
This structure of the description has been selected since, in most cases, you will only work on one  
item in the ”submenu”.  
If you want to work on several ”submenu” items in succession, you can select the individual items  
directly by means of the arrow keys.  
3.1.1. Key assignment  
F1-key:  
Leads to the table of contents.  
ENTER-key:  
ESC-key:  
ACK-key:  
Arrow keys:  
Confirms the entries.  
Goes back one step in the menu.  
Activates an alarm message; to unblock the control system.  
Move the cursor bar;  
switch the appliances on or off in combination with the SHIFT key;  
for scrolling forward or backward in a menu.  
SHIFT-key:  
HELP-key:  
Switches on the secondary functions of the keys,  
when the SHIFT-key has been pushed, the LED “SHIFT” is on.  
Viewing additional texts,  
when additional texts can be viewed the LED “HELP” is on.  
LED “ALARM”:  
flashes in case of an error;  
is on if the error has been acknowledged but not yet  
eliminated; is off if there are no errors  
LED = light emitting diode  
&
An additional alarm device (horn or lamp) can be connected (optional).  
Start-up 3-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STT 300  
3.1.2. Flow chart  
3
2
1
2
3
1
2
Indicator lamp  
Valve system  
3
4
Drying chamber  
Drying blower  
5
6
7
Return air filter  
Drying hopper  
Drying heater  
8
9
10  
Regeneration heater  
Regeneration blower  
Regeneration air filter  
Indicator lamp messages:  
Green continous light:  
Red continous light:  
in process  
alarm  
Start-up 3-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STT 300  
3.2. Switching on the dryer  
Switch on the system by means of the main switch.  
The control system carries through a self-test; after that, the name of the  
dryer and the operation status of the unit are displayed.  
&
Unblock the control system:  
Keep the ACK key pressed until the LEDs of the keys K1 - K4 light up.  
F
3.2.1. Operation statuses  
The following operation statuses can be displayed:  
system is off  
system is on  
blower runs on  
valve block  
regeneration will be finished in x min.  
Start-up 3-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STT 300  
3.3. Viewing the software-version  
Press the “±”-key.  
The software-version will be displayed.  
&
3.4. Passwords  
The entry of a password prevents unauthorised persons from having access to the data entered  
into the control system. Important data can then be entered or modified only after the password  
has been entered.  
If you make no entries for more than 10 minutes, the access is blocked and you have to re-enter  
the password.  
password level 6: 79 21 54  
Tell the password only to authorised persons.  
F
Press the ”Shift”-key and the ”K4”-key.  
Press 3 x the “â” key.  
Press the ”F3”-key.  
Start-up 3-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STT 300  
Login  
Press the key “F2".  
Enter the password.  
Press the ENTER key.  
If the password has been entered correctly, the corresponding password  
level is displayed.  
&
You can now enter data into the control system or modify data which have  
already been entered.  
Press the ESC key.  
Logout  
Press the key “F3".  
Only data for which no password is necessary (= password level 0) can  
now be entered into the control system or modified.  
&
Press the “â“ key.  
Edit  
Press the key “F2".  
This function is available only for password level 9.  
Passwords and password levels can be modified or entered.  
Confirm your entries by means of the ENTER key.  
&
Press the ”F1"-key.  
Start-up 3-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STT 300  
3.5. Basic parameters  
Press the ”F1"-key.  
3.5.1. Turning the devices on/off  
Select ”Main menu”.  
Acknowledge with the ENTER-key.  
or  
Press the ”F2”-key.  
Dryer on/off  
”on” = turn dryer on, ”off” = turn dryer off.  
Acknowledge with the ENTER-key.  
Timer on/off  
Press the SHIFT-key and choose with the arrow-keys the desired operation:  
”internal” = operation with timer (operation at OP7, see chapter timer),  
“external” = operation with timer (if present),  
”off” = operation without timer.  
Acknowledge with the ENTER-key.  
The timer is only operating, when the dryer is switched on.  
&
Press the “â” key.  
If the unit operates with a return air cooler (optional):  
&
Return air cooler on/off  
“on” = operation with return air cooler, “off” = operation without return air cooler  
Acknowledge with the ENTER-key.  
Press the “â” key.  
Start-up 3-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STT 300  
Hopper X on/off (X = number of the drying hopper)  
“on” = releasing drying hopper X, “off” = blocking drying hopper X  
Acknowledge with the ENTER-key.  
Hopper heater X on/off (X = number of the hopper heater)  
“on” = switch on hopper heater X, “off” = switch off hopper heater X  
Acknowledge with the ENTER-key.  
Press the ”F1"-key.  
Start-up 3-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STT 300  
3.5.2. Entering dryer values  
Select ”Dryer”.  
Acknowledge with the ENTER-key.  
or  
Press the ”F3”-key.  
Regeneration Heater Act.  
The regenerated heat temperature will be displayed.  
Used air Act.  
The current temperature of the used air will be displayed.  
Press the “â” key.  
Dew point max.  
Enter the maximum permissible (worst allowed) dew point temperature (-35 to 28 °C) (-31 to  
82.4°F).  
Acknowledge with the ENTER-key.  
Dew point Act.  
The current dew point temperature will be displayed.  
If there is a cable break “+0 °C” (32°F) is displayed.  
&
Press the “â” key.  
Start-up 3-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STT 300  
If the unit operates with a return air cooler (optional):  
&
Return air cooler Target  
Enter the max. permissible return air temperature (65 °C max.) (149°F). Higher temperatures are  
not allowed. Acknowledge with the ENTER-key.  
Return air cooler Act.  
The current return air temperature will be displayed.  
The cooling effect of the return air cooler is highly dependent on the  
cooler circuit.  
&
The lower the value chosen for the return air temperature, the better the  
efficiency of the drying cells.  
Plan the size of the coolant circuit accordingly.  
F
Press the ”F1"-key.  
Start-up 3-10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STT 300  
3.5.3. Entering hopper values  
Select ”Hopper”.  
Acknowledge with the ENTER-key.  
or  
Press the ”F4”-key.  
Hopper entry X Target  
(X = number of the drying hopper)  
Enter the drying temperature for hopper flap X (when operating with supplementary heating).  
Acknowledge with the ENTER-key.  
Hopper entry X Act.  
(X = number of the drying hopper)  
The current temperature at the feed opening of hopper flap X will be displayed.  
If there is a cable break “+0 °C” (32°F) is displayed.  
&
The lowest drying temperature setting of the hopper flap must be the  
same as or higher than the drying temperature.  
F
Press the “â” key.  
Start-up 3-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STT 300  
If the unit operates with motor flaps (optional):  
&
Granules X  
target: _ % = _ °C  
(X = number of the drying hopper)  
Enter the material temperature at which the flap (optional) on the drying hopper X should close.  
Confirm with the ENTER key.  
This value is entered in percent of the temperature on the hopper inlet.  
&
The material temperature calculated by the control system for closing the  
flap on the drying hopper X is displayed in °C.  
Granules X  
act.: _ °C  
(X = number of the drying hopper)  
The current material temperature in the drying hopper X is displayed in °C (optional, if there is a  
flap).  
Press the ”F1"-key.  
Start-up 3-12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STT 300  
3.5.4. Observing processing status  
Select ”Status”.  
Acknowledge with the ENTER-key.  
or  
Press the ”K1”-key.  
The current operation status of individual assembly parts is displayed:  
e.g.: valve block moved in/moved out/error  
&
“moved in” = The upper drying cells are within the drying circuit; the lower  
ones are regenerated.  
“moved out” = The upper drying cells are regenerated; the lower ones are  
within the drying circuit.  
“error” = An error has occurred.  
Other operation statuses:  
“on” = in operation,  
“off” = out of operation,  
“open” = opened,  
“shut” = closed.  
Press the “F1"-key.  
Start-up 3-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STT 300  
3.5.5. Setting date and time  
This function is password protected.  
&
Press the “K3"-key.  
Enter the password if requested.  
Date  
Press the SHIFT key.  
By means of the arrow keys, select the desired week-day.  
By means of the arrow keys, select the shown date.  
Press the SHIFT key.  
Enter the desired date.  
Press the ENTER key.  
Time  
Enter the desired time.  
Press the ENTER key.  
Press the ”F1”-key.  
Start-up 3-14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STT 300  
3.5.6. Viewing/changing language and contrast  
This function is password protected.  
&
Press the “K4"-key.  
Enter the password if requested.  
Contrast  
Press the SHIFT key.  
By means of the arrow keys, select the adjustment which suits you best.  
Press the ENTER key.  
Depending on the outside temperature, the brightness of the screen may  
vary.  
&
Language  
Press the SHIFT key.  
By means of the arrow keys, select the desired language (if present).  
Press the ENTER key.  
Press the “F1"-key.  
Start-up 3-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STT 300  
3.5.7. Changing parameters  
Select ”Parameters”.  
Acknowledge with the ENTER-key.  
or  
Press the SHIFT-key and the ”K1”-key.  
Run on time  
drying blower  
-- 300 sec.  
Standard setting: 300 seconds, changes only after contacting SterlingService.  
Press the “â” key.  
Parameters  
The values in this menu may only be changed after contacting  
SterlingService.  
F
Press the ”F1"-key.  
Start-up 3-16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STT 300  
3.5.8. Setting the timer  
Select ”Timer”.  
Acknowledge with the ENTER-key.  
or  
Press the SHIFT-key and the ”F1”-key.  
XX ON 00:00 OFF 00:00 (XX = day Mo-Su)  
Enter for each day the switching on time and the switching off time.  
Acknowledge with the ENTER-key.  
Example:  
&
Fr  
ON  
ON  
ON  
ON  
08:00  
00:00  
20:00  
00:00  
OFF 23:59  
OFF 23:59  
OFF 08:00  
OFF 00:00  
Sa  
Su  
Mo  
The dryer starts on Friday at 08:00 in the morning, runs through without  
interruption until sunday at 08:00 and switches off. At 20:00 the dryer  
starts again and switches off on Monday at 00:00.  
Press the ”F1"-key.  
Start-up 3-17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STT 300  
3.6. Starting continuous operation  
When you have carried through all basic settings, you can start with continuous operation.  
Make sure that hoppers which are not in use are separated from the  
dehumidified air supply.  
F
Make sure that the set drying temperatures are suited for the materials in  
the hoppers.  
After first filling, do not process the material until after the dwelling time.  
If a return air cooler is installed, switch on the coolant circuit of the return  
air cooler.  
Make sure that the cooling appliance is connected to the mains socket (if  
present, optional).  
Check setting of the timer.  
Select ”Main menu”.  
Acknowledge with the ENTER-key.  
or  
Press the ”F2”-key.  
Select ”Dryer on”.  
Acknowledge with the ENTER-key.  
Start-up 3-18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STT 300  
3.7. Viewing system runtime  
Select ”System runtime”.  
Acknowledge with the ENTER-key.  
or  
Press the SHIFT-key and the ”F2”-key.  
System runtime  
PLC  
r.-blwr.  
m.-blwr.  
X.XX h  
X,XX h  
X.XX h  
The runtime of the blowers and the PLC (SPS) is shown in hours.  
&
Start-up 3-19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STT 300  
3.8. Switching the dryer off  
Select ”Main menu”.  
Acknowledge with the ENTER-key.  
or  
Press the ”F2”-key.  
Select ”Dryer off”.  
Acknowledge with the ENTER-key.  
Wait until the regeneration phase is finished and the blower has come to  
a standstill.  
L
Switch off the dryer at the main switch.  
Disconnect the power supply.  
Never switch off the dryer directly at the main switch.  
F
Start-up 3-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Dehumidified Air Dryer  
4. Error and error correction  
This chapter is directed at the operators of the equipment.  
This chapter assumes general skills in dealing with drying systems and SPS  
(PLC) control units.  
»
This chapter assumes that the “start-up” description has been read and un-  
derstood.  
It should be ensured in each and every case that the operators have the rele-  
vant skills.  
Error and error correction 4-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Dehumidified Air Dryer  
Alarm messages are displayed in plain language on the screen of the  
operator device.  
&
The display of alarm messages in the operator device can only be erased  
by pressing the ”ACK” key. The failure is not repaired.  
A failure is given by flashing of the LED “alarm”. If the alarm message is  
acknowledged by pressing of the “ACK” key, but the failure is not yet eli-  
minated, the flashing changes to steady light.  
If a cooling appliance is present: If the temperature inside the switch box  
is higher than +50 °C, the lamp ”alarm - temperature inside switch box”  
goes on. If the temperature is still too high after 30 minutes, the dryer is  
switched off.  
Failures must be repaired immediately.  
F
LED “ALARM”:  
flashes in case of an error;  
is on if the error has been acknowledged but not yet eliminated;  
is off if there are no errors  
Press the ”K2"-key.  
Error and error correction 4-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dehumidified Air Dryer  
View  
Press the ”F2"-key.  
All alarm messages with their numbers (see Texts), date, time and the supplement ”K”, ”G”, or ”Q”  
are displayed.  
”K” = coming (a failure occured)  
Pressing the “à”-key displays the alarm message in plain text.  
&
”G” = going (the resent for the failure has gone)  
”Q” = reset (the display of the alarm message in the operator  
device has been erased by pressing the ”ACK”-key)  
Press the ESC-key.  
Print (Optional)  
This function is password protected.  
&
Make sure that a printer is connected and switched on.  
F
Press the ”F3"-key.  
The alarm messages are printed.  
Press the â”-key.  
Error and error correction 4-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dehumidified Air Dryer  
Number  
Press the ”F2"-key.  
Total messages  
The number of all alarm messages is displayed.  
Waiting messages  
The number of current alarm messages is displayed.  
Press the ESC-key.  
Delete  
Press the ”F3"-key.  
This function is password protected (Sterlingservice).  
&
Press the ENTER-key for deleting the messages.  
Press the ESC-key.  
Press the “â”-key.  
Error and error correction 4-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dehumidified Air Dryer  
Overflow  
Press the ”F2"-key.  
If there are more current alarm messages than can be saved, a warning  
message (= residual buffer reached) may be given.  
&
This function is password protected (Sterlingservice).  
Overflow warning On/Off  
Press the SHIFT-key.  
By means of the arrow keys, select ”on” if a warning message is to be given.  
By means of the arrow keys, select ”off” if no warning message is to be given.  
Press the ENTER-key.  
If the overflow warning message is given, press the ACK-key. Delete the  
alarm messages.  
F
Press the ESC-key.  
Error and error correction 4-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dehumidified Air Dryer  
Text  
Press the ”F3"-key.  
All possible alarm messages are displayed with their numbers (see Viewing).  
For viewing the possible alarm messages, press the arrow keys:  
PLC (= SPS) Battery is Empty  
Replace the SPS battery.  
Main Switch is Off  
The main switch has been placed in the off position.  
The safety temperature limiter of the drying or the regeneration heater, respectively, has been ac-  
tivated.  
The safety temperature limiter of a hopper heater has been activated.  
Error valve block.  
Check the safety temperature limiter.  
Check the position of the valve block.  
A Safety Temperature Limiter has been Activated  
Check the safety temperature limiter of the drying, regeneration, or hopper heater, respectively.  
Filter Door is Open  
The side panels to the air filters are open.  
Assemble side panels.  
The Safety Switch Regeneration Blower Has Been Actuated  
Check the blower.  
Check the fuses.  
Short circuit check of the blower.  
Vacuum Regeneration Blower  
The regeneration blower does not produce sufficient pressure.  
Check the blower.  
Vacuum sensor defective.  
The Safety Switch Drying Blower Has Been Actuated  
Check the blower.  
Check the fuses.  
Short circuit check of the blower.  
Vacuum Drying Blower  
The drying blower does not produce sufficient pressure.  
Error and error correction 4-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dehumidified Air Dryer  
Check the blower.  
Vacuum sensor defective.  
Temperature Measurement Regeneration Heater Defective  
Check the cables and the sensor.  
Check the power supply.  
Short circuit check.  
Excess Temperature Regeneration Heater  
The regeneration temperature is too high.  
Check the safety temperature limiter.  
SterlingService.  
Insufficient Temperature Regeneration Heater  
The regeneration temperature is too low.  
Check the regeneration heater.  
The Safety Switch Regeneration Heater Has Been Actuated  
Check the heater.  
Check the fuses.  
Short circuit check of the heater.  
Error Bypass Flap  
The bypass flap does not close or closes too slowly.  
Check the bypass flap.  
Error Valve Block  
The valve block has not reached the proper position. The main switch is placed in the off position.  
Check the position of the valve block. Press the “ACK” key and put the main switch in the on positi-  
on immediately. If the valve block has not reached the correct position within 1 minute, the main  
switch is again placed in the off position.  
SterlingService.  
Temperature Measurement Outgoing Air Defective  
Check cables and sensor.  
Temperature Measurement Return Air Defective  
Check cables and sensor.  
Excess Temperature Return Air  
Check cables and sensor.  
Check the return air cooler.  
Error and error correction 4-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dehumidified Air Dryer  
Temperature Measurement Drying Heater Defective  
Check cables and sensor.  
Check the power supply.  
Short circuit check.  
Excess Temperature Drying Heater  
The drying temperature is too high.  
Check the safety temperature limiter.  
SterlingService.  
Insufficient Temperature Drying Heater  
The drying temperature is too low.  
Check the drying heater.  
Safety Switch Drying Heater  
Check the heater.  
Check the fuses.  
Short circuit check of the heater.  
Temperature Measurement Heater Defective Hopper X  
(X = number of the drying hopper)  
Check cables and sensor.  
Check the power supply.  
Short circuit check.  
Excess Temperature Heater Hopper X  
(X = number of the drying hopper)  
The temperature of the hopper heater is too high.  
Check the safety temperature limiter.  
SterlingService.  
Insufficient Temperature Heater Hopper X  
(X = number of the drying hopper)  
The temperature of the hopper heater is too low.  
Check the hopper heater.  
Safety Switch Heater Hopper X  
(X = number of the drying hopper)  
Check the heater.  
Check the fuses.  
Short circuit check of the heater.  
Error and error correction 4-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dehumidified Air Dryer  
Temperature Measurement Granules Defective Hopper X  
(X = number of the drying hopper)  
Check cables and sensor.  
Check the power supply.  
Short circuit check.  
Excess Temperature Granules Hopper X  
(X = number of the drying hopper)  
The material temperature is too high.  
Check the heater.  
Check the throttle valve.  
Valve Error Hopper X  
(X = number of the drying hopper)  
The throttle valve does not close or closes too slowly.  
Check the throttle valve.  
Press the “F1"-key.  
Error and error correction 4-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STT 300  
5. Maintenance  
This chapter is intended for persons with skills in electrical and mechanical  
areas due to their training, experience and received instructions.  
»
Personnel using the instructions in this chapter must be instructed of the re-  
gulations for the prevention of accidents, the operating conditions and safety  
regulations and their implementation.  
Ensure in each case that the personnel are informed.  
For maintenance work taking place at heights of over approx. 6 feet  
(1829mm), use only ladders or similar equipment and working platforms in-  
tended for this purpose. At greater heights, the proper equipment for protec-  
tion against falling must be worn.  
Use only suitable lifting gear which is in proper working order and load sus-  
pension devices with sufficient carrying capacity. Do not stand or work under  
suspended loads!  
Ensure that the electric motors/switch cabinets are sufficiently protected  
against moisture.  
Use only suitable workshop equipment.  
Before starting maintenance work, appoint a supervisor.  
Inform the responsible personnel before maintenance work on the system is  
started.  
Never operate the equipment when partially dismantled.  
All maintenace and repair work not described in this chapter, may only be  
carried out by Sterling service personnel or authorized personnel (appointed  
by Sterling).  
Disconnect the equipment from mains supply before starting maintenan-  
ce procedures to ensure that it cannot be switched on unintentionally.  
L
Depressurize all compressed air piping of the equipment before starting  
maintenance work.  
Maintenance 5-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STT 300  
Please observe the maintenance schedule.  
Before starting maintenance work, clean the equipment of oil, fuel or lu-  
bricants.  
F
Ensure that materials and incidentals required for operation as well as  
spare parts are disposed of properly and in an environmentally sound  
manner.  
Use only original Sterling spare parts.  
Keep record of all maintenance and repair procedures.  
Maintenance 5-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STT 300  
5.1. Maintenance intervals  
Daily:  
Check warning signs on equipment for good  
legibility and completeness  
Clean return air filter and housing  
(depending on amount of dust collected)  
Lamp test: if you press the ”+/-”-button longer than  
2 seconds all LED’s must light up  
Weekly:  
Monthly:  
Check function of the main switch  
Clean filter of the electrical cabinet  
(depending on amount of dust collected)  
Check V-belt tension of blower  
Every three months: Clean filter of the regeneration blower  
(depending on amount of dust collected)  
Every six months:  
Exchange return air filter  
(depending on amount of dust collected)  
Exchange filter of the electrical cabinet  
(depending on amount of dust collected)  
Check all electrical and mechanical connections for tight fit.  
Yearly:  
Exchange filter of the regeneration blower  
(depending on amount of dust collected  
This maintenance schedule is calculated for 3-shift operation.  
The given maintenance intervals are average values.  
&
Check whether in your individual case the maintenance intervals must be  
shortened.  
F
Maintenance 5-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STT 300  
5.2. Cleaning/renewing the air filters  
Press the ”F2”-key.  
Select ”Dryer off”.  
Acknowledge with the ENTER-key.  
Wait until the blowers have stopped turning.  
L
Switch off the dryer at the main switch.  
Disconnect the power supply.  
Open the upper panel by means of the provided switch cabinet key.  
F
Clogged filters reduce the volume of circulating air to a substantial de-  
gree and result in decreased dryer efficiency. In addition, the heating ele-  
ments may be damaged due to clogged filters.  
&
Maintenance 5-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STT 300  
Return air filter  
Loosen the securing nut on the return air filter housing  
and remove the housing lid.  
Return air filter  
Regeneration air filter  
Remove the return air filter.  
Clean the return air filter with compressed air from in-  
side to out or renew the filter. Never knock the return  
air filter on the floor.  
Clean the return air filter housing. Use lint-free clea-  
ning rags.  
Re-install the cleaned/new return air filter.  
Mount the lid and fasten the securing nut.  
Close the panel.  
Filter of the electrical cabinet  
STT 300  
Never operate the dryer without return air filter.  
The dryer can’t be put into operation if the panel is not replaced.  
F
Order number return air filter if operated  
&
with return air cooler:  
ID 88226  
ID 86378  
without return air cooler:  
Maintenance 5-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STT 300  
Regeneration air filter  
Loosen the securing nut on lid of the regeneration air filter.  
Remove the lid and regeneration air filter housing.  
Loosen the two wing nuts.  
Remove the circular grid.  
Remove the filter mat.  
Blow through the filter mat with compressed air from the inside to the outside, or renew the filter.  
Re-install the cleaned/new filter.  
Replace the circular grid.  
Fasten the two wing nuts on.  
Replace the regeneration air filter housing and the lid of the regeneration air filter.  
Fasten the securing nut onto the regeneration air filter.  
Close the panel.  
Never operate the dryer without regeneration air filter.  
The dryer can’t be put into operation if the panel is not replaced.  
F
Order number filter mat:  
ID 93686  
&
Maintenance 5-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STT 300  
Filter of the electrical cabinet  
Remove the lid of the filter.  
Remove the filter mat.  
Blow through the filter mat with compressed air from inside to outside or renew the filter mat.  
Clean the filter housing. Use lint-free cleaning rags.  
Re-install the cleaned/new filter mat.  
Replace the lid of the filter.  
Never operate the dryer without filter mat.  
F
Order number filter mat:  
ID 87491  
&
Maintenance 5-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STT 300  
5.3. Tensioning the V-belts  
Press the ”F2”-key.  
blower ”regeneration heater”  
Select ”Dryer off”.  
Acknowledge with the ENTER-key.  
Wait until the blowers have stopped turning.  
L
Switch off the dryer at the main switch.  
Disconnect the power supply.  
blower ”drying heater”  
STT 300  
Open the upper panel by means of the provided switch cabinet key.  
F
Order number V-belts blower  
&
”regeneration heater”:  
”drying heater”:  
ID 93741  
ID 94211  
Maintenance 5-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STT 300  
Blower ”regeneration heater” / Blower ”drying heater”  
1
2
3
6
5
4
3
Remove the protective grid of the blower (position 3).  
Loosen the nut (position 1).  
Loosen and remove the screw (position 2).  
Slide motor with carrier flange plate (position 6) towards the carrier flange housing (position 4).  
Remove defective V-belts (position 5), put on new ones.  
Attention should be given to exact alignment of the V-belt pulleys.  
F
Adjust belt tension by screw (position 2) in accordance with the information sticker.  
Tighten the nuts on threaded bolt (position 1) again.  
Mount the protective grid of the blower (position 2).  
Mount the side panels.  
Maintenance 5-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STT 300  
High-pressure blowers with frequency converter operation  
Blowers work without V-belts!  
F
5.4. Disposing of the drying agent  
Ensure that drying cells are exchanged by Sterlingor refilled only when empty.  
Drying agents must be disposed of in accordance with all official regula-  
tions.  
Used drying agents are to be disposed of as hazardous waste, as it may  
be contaminated with foreign substances from the materials dried in the  
system.  
Used drying agents or drying cells containing used drying agent cannot  
be returned to Sterling.  
F
5.5. Servicing the accessories  
The operating instructions must be followed.  
F
Maintenance 5-10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STT 300  
5.6. Changing the battery of the control system  
This work may be carried through only by qualified personnel trained in the  
field of electrical engineering.  
»
The battery may be changed only with the control system switched on.  
F
Open the control box by means of the control box key which is part of the supply.  
Open the front door of the CPU.  
Pull the backup battery with cable out of the compartment.  
Plug the connector of the new backup battery into the corresponding socket in the battery compartment of  
the CPU.  
The notch on the battery connector must point to the left!  
&
Place the backup battery into the battery compartment on the CPU.  
Close the front door of the CPU  
Close the control box.  
Maintenance 5-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STT 300  
Store backup batteries in a dry and cool place.  
Backup batteries can be stored for approx. 5 years.  
L
If backup batteries are not treated properly, they can ignite, explode and  
cause severe burning.  
Order number battery:  
ID 83809  
&
Batteries must be disposed of in keeping with the relevant national envi-  
ronment protection regulations/guidelines.  
Maintenance 5-12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STT 300  
5.6.1. Resetting the control values  
This electrical work is intended to be carried out only by trained personnel.  
»
&
After changing the battery or the PLC the control values should be reset-  
ted.  
All control values are set back to the standard settings.  
Open the control box with the switch box key which is part of the supply.  
Turn the key to the STOP position.  
Turn the key to the MRES position.  
Hold the key in this position until the STOP-LED comes on for the second time and remains on  
(this takes 3 seconds).  
Turn the key to the STOP position.  
Within 3 seconds you must turn the switch back to the MRES position.  
Hold the key until the STOP-LED flashes.  
When the CPU has completed the reset, the STOP-LED stops flashing  
and remains lit.  
&
Close the control box.  
Maintenance 5-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STT 300  
6. Functional description  
This functional description is intended for all operating personnel of the  
equipment.  
»
Prerequisite for this functional description is general knowledge of dryers  
and SPS (PLC) systems.  
Ensure in each case that the operating personnel are sufficiently informed.  
Functional description 6-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STT 300  
6.1. Dryer  
The dryer operates with dehumidified air, i.e. the air is not only heated but also dehumidified befo-  
re flowing into the drying hopper. This principle allows plastic granules to be dried to a residual  
moisture content as low as 0.002 % (PET granulate).  
The dryer operates continuously, i.e. dehumidified and, if necessary, heated air is produced con-  
tinuously.  
The dryer is designed for continuous operation.  
F
The dryer operates with 2 drying cells; one of these cells is always in the drying cycle while the ot-  
her is being regenerated (change-over after 3 hours).  
If a malfunction occurs in the drying cycle during the program run, regeneration is not interrupted,  
but continues until the program end has been reached. This guarantees that 1 regenerated drying  
cells is always available.  
The air inside the switch cabinet is cooled by a cooling appliance for the protection of temperatu-  
re-sensitive components (if present, optional).  
With the digital timer the dryer can be switched on and off at set times.  
Dew point dependent regeneration switch (optional)  
The dew point temperature is monitored continuously. The valve system switches to the freshly  
regenerated drying cells only after the selected dew point temperature has been reached. The hu-  
mid drying cells are then regenerated. After the cooling time the drying cells are ready for operati-  
on again. The valve system switches to the freshly regenerated drying cells only after the moistu-  
re content of the drying cells which are in the drying cycle have reached the setpoint value.  
Functional description 6-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STT 300  
6.2. Drying hopper (optional)  
The material is dried in the drying hopper. The dehumidified air is forced through the material in  
the hopper, collecting moisture in the process. The drying hopper must be dimensioned accor-  
ding to its intended use to ensure that the final moisture content is attained. When the hopper is fil-  
led for the first time or at the start of a drying procedure, the material in the hopper must be dried  
completely before material can be removed from the hopper for the first time.  
When material is continuously removed from the hopper, material must also be continuously fed  
into the drying hopper. The new (moist) material is fed into the drying hopper from the top and  
slowly moves downward toward the material suction box. As the material moves upward, it is  
dried until its final moisture content is attained.  
To ensure proper continuous drying, we recommend that the drying hopper always is kept com-  
pletely filled. Automatic conveyors, such as the models included in our delivery program, optimize  
the automation of the material flow.  
When material is continuously removed from the hopper, but no material  
is continuously fed into the drying hopper (batch drying), the material le-  
vel may not fall below 40 %.  
F
Close the throttle valves.  
Functional description 6-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STT 300  
6.3. Return air cooler (optional)  
A return air cooler is generally required in cases in which the return air  
temperature is over 65 °C (149°F).  
F
A return air cooler improves the efficiency of the drying cells.  
The return air cooler reduces the return air temperature to a defined value.  
The return air temperature is set at the operation panel.  
The lower the value chosen for the return air temperature, the better the  
efficiency of the drying cells.  
&
The dryer is automatically switched off if temperature exceeds 80 °C  
(176°F).  
Return air temperature is continuously monitored; the return air cooler is activated only when nee-  
ded. If the return air temperature exceeds the set value (e.g. due to interruption in the cooling wa-  
ter supply or soiling), an alarm message is given.  
The return air cooler can be connected to a coolant circuit or to the water mains network.  
Functional description 6-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STT 300  
6.4. Hopper heaters (optional)  
If differing drying temperatures are required in the different drying hoppers, hopper heaters must  
be installed on the drying hoppers. The drying temperature of each drying hopper can be set cen-  
trally at the dryer.  
6.5. Automatic motor flaps (optional)  
Automatic motor flaps cut off the drying hopper from the drying circuit as soon as the material is  
completely dried. The supplementary heating system is also switched off. Dehumidified air flows  
into the drying hopper only after new, moist material is added to the hopper. This ensures that the  
material is not damaged, and saves a considerable amount of energy.  
Temperature probes at the feed opening of the drying hopper and inside the drying hopper enable  
comparison of feed opening and material temperature, from which the drying degree of the mate-  
rial can be calculated.  
If the drying hopper is to be cleaned or blocked, the motor flap can be closed via the dryer. The  
supplementary heating system is then automatically switched off.  
6.6. Connection to a pneumatic conveying system (optional)  
The dryer operates most effectively in conjunction with a pneumatic conveying system. This com-  
bination of dryer and conveying system ensures that sufficient material is always fed into the dry-  
ing hopper.  
Only the amount of material required for the processing machines used is removed from the hop-  
per. This guarantees that the final drying result remains constant.  
Sterlingdrying hoppers are available equipped with the corresponding flange for connection of a  
Sterlingpneumatic conveyor directly ex works.  
Suction boxes can also be delivered with the required number of suction tubes. These suction bo-  
xes were developed specially for this hopper to prevent dust and foreign particles from being aspi-  
rated into the system.  
A device for connection to the dehumidified air supply line is also available. Please note that the  
function of this combination is different from that of the conventional Sterling suction boxes.  
Functional description 6-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Dehumidified Air Dryer  
7. Transport, Assembly and Storage  
This chapter is intended for all operating personnel of the equipment.  
Personnel using these instructions must be instructed in the regulations for  
the prevention of accidents, the operating conditions and safety regulations  
and their implementation.  
»
Ensure in each case that the operating personnel are sufficiently informed.  
Please inform all persons within the range of action of the equipment of the  
direct and indirect hazards connected with the equipment.  
Please observe all safety regulations for the operation of lifting equipment.  
Transport, Assembly and Storage 7-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Dehumidified Air Dryer  
7.1. Transport and Packing  
Please ensure adequate carrying capacity of the lifting equipment.  
Note that the dryer system is top-heavy. Risc of toppling!  
»
Please check packing on delivery for transport damage.  
The equipment pass a rigorous operating test in the factory and are packed carefully to avoid  
transport damage.  
The inlet and discharge flanges are sealed with plugs, so that no dirt can enter during transport.  
Plugs must be removed before assembly.  
Packing materials should be disposed of according to environmental laws or reused.  
Only use for transport of the equipment a suitable lifting device (e. g. a fork lift truck or a workshop  
crane).  
Fasten the transport cables to the eyelets of the control cabinets.  
Transport must be shock-proofed and free from vibrations.  
with a fork lift truck  
Push the forks up to the dryer housing.  
Check that the forks reach completely under the dryer housing.  
Transport with a fork lift truck  
Transport, Assembly and Storage 7-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Dehumidified Air Dryer  
with a workshop crane  
Check if the eyelets are installed on the dryer housing.  
If this condition is met, fasten the transport cables to the eyelets.  
If this condition is not met, mount the eyelets and then fasten the transport cables to the eyelets.  
Disassemble the eyelets after set-up.  
Transport with a workshop crane  
Transport, Assembly and Storage 7-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dehumidified Air Dryer  
7.2. Assembly  
Please ensure adequate carrying capacity of the lifting equipment.  
Check the carrying capacity of the point of installation, particularly if installed  
on a platform.  
»
The place selected for installation should be as free of vibrations as possible.  
The main switch must be freely accessible.  
Ground the equipment against electrostatic charging.  
A special foundation is not required for installation.  
The dryer must be installed on a level surface, and may not be exposed to excessive humidity.  
Maximum permissible ambient temperature of the control system is 45 °C (113°F).  
To facilitate servicing, install the dryer such that it is accessible from 3 sides. Make sure that the  
air filters can be changed without problems. The rear of the dryer can be placed against a wall.  
To conserve energy, keep the distances between dryer, hopper and processing machine as short  
as possible.  
The location of the control unit should be chosen so that a clear view of the separators is guaran-  
teed from the control unit. Thus any malfunctions which arise can be corrected more easily.  
Fasten the transport cables to the eyelets of the control cabinets. During transport do not contact  
or push against other components with the control panels.  
7.3. Storage  
The control system may only be stored at temperatures from -25 to +55°C (-13 to +131 °F).  
Between delivery and machine commissioning the equipment should be stored in a dry, dust-free  
and vibration-free room.  
Transport, Assembly and Storage 7-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Dehumidified Air Dryer  
8. Assembly instructions  
Version: 64.10-8248GB01 04/02  
These installation instructions are intended for persons with skills in electri-  
cal and mechanical areas due to their training, experience and received in-  
structions.  
»
Personnel using these installation instructions must be instructed in the reg-  
ulations for the prevention of accidents, the operating conditions and safety  
regulations and their  
implementation.  
Ensure in each case that the personnel are informed.  
The installation instructions provided in the corresponding operating instruc-  
tions apply for all connected equipment.  
Observe safety regulations with regard to lifting gear handling  
All installation work must be carried out with the equipment disconnected  
from electrical power and compressed air supply.  
For installation work taking place at heights of over approx. 6 feet (1829  
mm), use only ladders or similar equipment and working platforms inten-  
ded for this purpose. At greater heights, the proper equipment for protec-  
tion against falling must be worn.  
L
Use only suitable lifting gear which is in proper working order and load  
suspension devices with sufficient carrying capacity. Do not stand or  
work under suspended loads!  
Use suitable workshop equipment.  
Install the equipment such that all parts are easily accessible; this facili-  
tates maintenance and repair work.  
F
Assembly instructions 8-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Dehumidified Air Dryer  
8.1. Mounting of the suction device for regeneration exhaust air  
When plastics are dried which produce hazardous gases, environmentally sound disposal of the  
regeneration exhaust air must be provided. The throughput of the regeneration blower may not be  
changed.  
It must be taken into consideration when installing a disposal system (e.g. exhaust system) that  
regeneration exhaust air is extremely humid. This may result in condensation water which must  
not enter the dryer again under any circumstances.  
8.2. Connection of the air coolers (optional)  
A return air cooler is generally required in cases in which the return air  
temperature is over 65 °C (149°F).  
F
The return air cooler can be connected to a coolant circuit or the water mains network.  
Observe the water flow with connection to water mains network. The coolant circuit must be di-  
mensioned acccordingly.  
Remove the side panel of the dryer.  
Connect the coolant intake line and coolant return line to the return air cooler.  
Obeserve the flow direction of the coolant through the return air cooler.  
Check the connections for leaks.  
Mount the side panel.  
Assembly instructions 8-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Dehumidified Air Dryer  
8.3. Electrical connection  
Observe the rules of the local electricity board.  
Check that the supply voltage and the power frequency are in accordance  
with the data on the name plate of the device.  
»
The electrical connection may only be carried through or assigned by Ster-  
ling service staff or by qualified staff authorized by Sterling.  
Other persons are not permitted to carry through the electrical connection.  
The main switch must be freely accessible.  
Ground the equipment against electrostatic charging.  
Observe that the control system is still under voltage even when the  
mains switch is switched off.  
L
Regularly make sure that none of the electrical or screw connections are  
loose.  
F
Immediately after connection, check the direction of rotation of the blo-  
wers (see rotational direction arrow on the blowers).  
The direction of rotation should be switched in the supply line only.  
The operation voltage is 400 V/3AC/PEN/50 Hz.  
Special operation voltages are possible.  
Assembly instructions 8-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STT 300  
9. Technical Data  
Basic Equipment  
· Centrally monitored Mitsubishi drying control system with operator panel OP 7  
· Central temperature controls for all heating elements to ensure constant temperature levels  
· Safety temperature limiter for all heaters  
· Designed for optimal regeneration time due to constant monitoring of the moisture level in the  
drying cells or desiccant beds.  
· Maintenance free air valves  
· Automatic alarm clock or timer  
· Optical alarm indication  
· Function control with flow diagram  
Optional Equipment  
· Dew point display  
· Return air cooler for high processing temperatures  
· Pre-air filter  
· Special color  
· Special voltage  
· Printer interface  
· Fuzzy Logic control for automatic air distribution  
· Condensation collection chamber  
· High-pressure blowers with frequency converter operation  
Performance  
· Maximum air drying capacity of 500 m3/h (10,620 cu.ft./hr)  
· Operates with 400 V +/-10%, 3AC, 50 Hz voltage  
Special voltage possible 480/3/60  
· 16 kW connected load + max. 24 kW hopper heatings  
· Noise level: 83 dB (A)  
· Weight approx. 500 kg (1102.39 lbs)  
Technical Data 9-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STT 300  
Dimension sheet  
All dimensions are in mm (in). Subject to alteration.  
Technical Data 9-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STT 300  
10. Spare parts list  
This spare parts list is intended to be used only by trained personnel.  
Other persons are not permitted to modify or repair the equipment.  
»
ID-numbers for units with special voltage, for ex. blowers, only on re-  
quest.  
&
Spare parts list 10-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STT 300  
3
4
2
1
12  
Pos.  
ID-number Description  
1
87788  
93741  
High-pressure blower HRD 1/2, 0,5 kW, 400 V/50 Hz  
V-belt  
97762  
95819  
Silicon hose  
Pull-button  
2
95828  
85276  
Tubular heating element 230 V, 3 kW (drying, optional)  
Temperature limiter STB 160-250 °C (drying, optional)  
3
4
86363  
Spindle motor 24 V  
87094  
93795  
85275  
Tubular heating element 230 V, 3 kW (regeneration)  
Tubular heating element 230 V, 2450 W (regeneration)  
Temperature limiter STB 360-500 °C (680-932°F) (regeneration)  
12  
83986  
Moisture sensor  
Spare parts list 10-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STT 300  
5
6
PE  
11  
7
8
10  
9
Pos.  
ID-number Description  
5
6
86378  
Filter cartridge (if no return air cooler is in use)  
93687  
93686  
Fine-mesh filter with filter mat (complete)  
Filter mat for fine-mesh filter  
7
8
14208  
96196  
Drying cell, complete  
Drying agent  
05190  
85682  
Valve stem, complete  
Micro-switch  
9
84156  
84157  
87491  
Fan  
Filter unit complete  
Spare filter mat  
10  
87787  
94211  
High-pressure blower HRD 1/5, 1,1 kW, 400 V/50 Hz  
V-belt  
97762  
95819  
Silicon hose  
Pull-button  
Optional:  
S82524  
83023  
83022  
High-pressure blower HRD 1TFU, with frequency converter operation  
Frequency converter  
Operating unit  
11  
84157  
87491  
Filter unit complete  
Spare filter mat  
Spare parts list 10-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STT 300  
Accessories  
85241 Digital timer (extern, optional)  
86371 Multiplier Pt 100 (3 m) (9.84 ft)  
89846 Multiplier Pt 100 (6 m) (19.79 ft)  
93303 Multiplier Pt 100 (9 m) (29.53 ft)  
86387 Multiplier Pt PT 100 (12 m) (39.47 ft)  
83015 Multiplier Pt 100 (15 m) (49.21 ft)  
Return air coler (optional)  
29787 Return air coler  
87099 Solenoid valve 24 V  
84503 Temperature converter  
88226 Filter cartridge, temperature-proof (if a return air cooler is in use)  
Flaps (optional)  
16522 Motor flap NW150, complete  
16517 Motor flap NW80, complete  
86376 Motor operator 24 V, AD/DC, 50-60 Hz  
18232 Air control flap  
84492 Thermometer  
Hopper heaters (optional)  
85343 Radiator (1,5 kW)  
85338 Radiator (3 kW)  
85363 Radiator (6 kW)  
85651 Radiator (9 kW)  
85652 Temperature limiter STB hopper heaters  
10.1. Switching Cabinet and Operating Unit  
Observe spare parts list in the electrical manual.  
&
Spare parts list 10-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Dehumidified Air Dryer  
11. Electrical manual  
This electrical manual is intended to be used only by Sterling service  
personnel and trained personnel authorized by Sterling.  
Other persons are not permitted to modify or repair the equipment.  
¨ Connection diagram no.: _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _  
¨ Currently not available; will be delivered at a later date!  
Electrical manual 11-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Dehumidified Air Dryer  
12. Accessories  
¨ Entering values on the OP 7 / 17  
¨ Flap control with Fuzzy-Logic  
¨ Elektror High-pressure blower with frequency converter operation  
¨ Elektror High-pressure blower  
¨ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _  
¨ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _  
Accessories 12-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Accessories  
Entering values on the OP 7 / 17  
Sterling Material Processing  
Download from Www.Somanuals.com. All Manuals Search And Download.  
General Operation  
3.3 Entering Values  
General procedure  
In input fields, values can be entered on the OP and transferred to the PLC.  
To do this, proceed as follows:  
Step  
Procedure  
Branch initially to the screen you  
require and then to the corresponding screen entry.  
1
2
3
Using the arrow keys, select the input field you require within the  
screen entry.  
Then enter your value. Depending on how the field has been con-  
figured, values may be input as  
inputs of numerical values (refer to section 3.3.1),  
inputs of alphanumeric values (refer to section 3.3.2),  
inputs of symbolic values (refer to section 3.3.3).  
4
Confirm your input with  
You can cancel any incorrect  
input by pressing  
ESC  
The original value is then automatically reinserted in  
the field. Insert the correct value and then enter the  
corrected value by pressing  
5
6
Position the cursor in the next input field, insert the next value  
etc.  
You can also use the arrow keys to move the cursor to the left or  
right to the previous input field to insert a different value in it.  
ESC  
Close the screen by pressing  
OP7, OP17  
09/96  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
General Operation  
3.3.1  
Entering Numerical Values  
Input using numer-  
ical keypad  
In fields that allow the operator to enter a numerical value, you enter the nu-  
merical value character by character using the keypad on the system key-  
board.  
Changing the  
value  
If there is a value in the field already, it is cleared completely from the field  
when the first character is entered. Once input has been started, you cannot  
exit from the field until the input has been entered or canceled.  
Right-justified  
input  
In numerical fields, input initially is normally right-justified. Digits that have  
already been entered are moved to the left (pocket-calculator format).  
Exception:  
Input fields for variables in KM format – for instance, when calling the PU  
functions STATUS/FORCE VAR – are changed to left-justified . When input  
begins, the old value does not disappear from the display completely but its  
bit pattern is overwritten one character at a time. You move the cursor in this  
type of field by pressing  
or  
with activated Shift Lock mode.  
Limit-value check  
Decimal places  
You can configure limit values for numerical input fields. In this type of  
field, a limit-value check takes place, i.e. the entered values are applied only  
if they lie within the configured limits. If a value outside these limits is en-  
tered, a system message is displayed and, after it has been canceled, the old  
value is restored in the field.  
If a numerical field has been configured with a certain number of decimal  
places and too many have been entered, they are ignored; if too few have  
been entered, the field is padded with zeroes.  
OP7, OP17  
09/96  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
General Operation  
3.3.2  
Entering Alphanumeric Values  
Mixed input of  
With the input of alphanumeric values, digits and letters are mixed.  
digits and letters  
For the numerical components of the input, proceed as described in section  
3.3.1. If, however, you wish to enter a letter at the current cursor position,  
you must enable the corresponding alphanumeric font. In this instance, you  
move the cursor with activated Shift Lock mode with  
and  
.
Entering A to F  
characters  
A to F characters can be entered directly with activated Shift Lock mode  
using numeric keys 1 to 6. If you want to enter digits again after the letters,  
Shift Lock mode must be de-activated. To enter the alphanumeric string  
7FEB53, for example, proceed as follows:  
Step  
Procedure  
1
Press  
7
2
3
4
5
6
Press  
Shift-LED is on.  
\
Press in succession  
5E  
2B  
6F  
Press  
Shift-LED goes out.  
\
Press in succession  
Confirm by pressing  
3C  
5E  
\b  
OP7, OP17  
09/96  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
General Operation  
Extended charac-  
ter set  
If the characters available on the keypad are not sufficient for the alphanu-  
meric input, you can select additional letters and special characters from the  
extended character set. The extended character set is available for all KC  
type fields.  
To enter the string 18OKT61, for example, proceed as follows:  
Step  
Procedure  
1
Press in succession  
1A  
8
2
Press  
Shift-LED is on.  
\
The extended character set is available.  
3
4
Scroll with the arrow  
keys through the extended  
character set.  
Select O and, using the  
arrow key, move right  
one position.  
The character you selected is applied by moving the cursor.  
5
6
Select K and, using the  
arrow key, move right  
one position.  
Select T and, using the  
arrow key, move right  
one position.  
7
8
9
Press  
Shift-LED goes out.  
\
Press in succession  
1A  
6F  
Confirm by pressing  
\b  
OP7, OP17  
09/96  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
General Operation  
3.3.3  
Entering Symbolic Values  
Text instead of a  
value  
When you enter a symbolic value, text is displayed instead of the value. If a  
field has to be filled by entering symbolic values, take the value from a list of  
options. To do so, proceed as follows:  
Step  
Procedure  
1
In the input field press  
Shift LED is on.  
\
The list of options with its configured symbolic inputs  
is activated.  
2
3
Select the value you require using the arrow keys.  
Enter the value you  
\b  
selected by pressing  
Shift Lock mode is de-activated automatically.  
OP7, OP17  
09/96  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Accessories  
Flap control  
with Fuzzy-Logic  
Sterling Material Processing  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Flap control with Fuzzy-Logic  
Observe that the hopper is not switched off after the flap has closed.  
Turning hopper off: see chapter “start-up, turning the devices on/off”.  
F
Control unit “flap”  
Switch position:  
0
= “Quick closing”  
flap closes quick  
1 = “Slow closing”  
flap closes controlled  
2 = “Automatic control”  
flap operates pulsed  
(opening/closing)  
0
1
2
2
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sennheiser Home Theater System SET 820 RF User Manual
Sennheiser Microphone SK 250 User Manual
Sharp Microwave Oven R 92STM User Manual
Sharp Projector XG MB55X L User Manual
Smooth Fitness Treadmill 825E User Manual
Sony DVD VCR Combo DIGITAL8 User Manual
Sony Personal Computer VGC RB31P User Manual
Stamina Products Bicycle 15 5325 User Manual
Sterling Plumbing Dehumidifier 100 User Manual
SUPER MICRO Computer Personal Computer X9SPV F User Manual