Speco Technologies Security Camera CVC 927PTZ User Manual

SPECO TECHNOLOGIES CVC-927PTZ DOME CAMERA  
Instruction Manual  
Please read this manual thoroughly before use and keep it handy for future reference.  
Rev.040812  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FCC COMPLIANCE STATEMENT  
FCC INFORMATION: THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO  
COMPLY WITH THE LIMITS FOR A CLASS A DIGITAL DEVICE, PURSUANT TO  
PART 15 OF THE FCC RULES. THESE LIMITS ARE DESIGNED TO PROVIDE  
REASONABLE PROTECTION AGAINST HARMFUL INTERFERENCE WHEN  
THE EQUIPMENT IS OPERATED IN A COMMERCIAL ENVIRONMENT. THIS  
EQUIPMENT GENERATES, USES, AND CAN RADIATE RADIO FREQUENCY  
ENERGY AND IF NOT INSTALLED AND USED IN ACCORDANCE WITH THE  
INSTRUCTION MANUAL, MAY CAUSE HARMFUL INTERFERENCE TO RADIO  
COMMUNICATIONS. OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL  
AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE  
USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN  
EXPENSE.  
CAUTION: CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY  
THE PARTY RESPONSIBLE FOR COMPLIANCE COULD VOID THE USER'S  
AUTHORITY TO OPERATE THE EQUIPMENT.  
THIS CLASS A DIGITAL APPARATUS COMPLIES WITH CANADIAN ICES-003.  
CET APPAREIL NUMÉRIQUE DE LA CLASSE A EST CONFORME À LA NORME  
NMB-003 DU CANADA.  
CE COMPLIANCE STATEMENT  
WARNING  
THIS IS A CLASS A PRODUCT. IN A DOMESTIC ENVIRONMENT THIS  
PRODUCT MAY CAUSE RADIO INTERFERENCE IN WHICH CASE THE USER  
MAY BE REQUIRED TO TAKE ADEQUATE MEASURES.  
III  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFEGUARDS  
1. Read these instructions.  
2. Keep these instructions.  
3. Heed all warnings.  
4. Follow all instructions.  
5. Do not use this apparatus near water.  
6. Clean only with dry cloth.  
7. Do not block any ventilation openings. Install in accordance with the  
manufacturer's instructions.  
8. Do not install near any heat sources such as radiators, heat  
registers, stoves, or other apparatus (including amplifiers) that  
product heat.  
9. Do not defeat the safety purpose of the polarized or grounding-type  
plug. A polarized plug has two blades with one wider than the other.  
A grounding type plug has two blades and a third grounding prong.  
The wide blade or the third prong are provided for your safety. If the  
provided plug does not fit into your outlet, consult an electrician for  
replacement of the obsolete outlet.  
10.Protect the power cord from being walked on or pinched particularly  
at plugs, convenience receptacles, and the point where they exit from  
the apparatus.  
11. Only use attachments/accessories specified by the manufacturer.  
12. Unplug this apparatus during lightning storms or when unused for  
long periods of time.  
13. Refer all servicing to qualified service personnel. Servicing is  
required when the apparatus has been damaged in any way, such as  
power-supply cord or plug is damaged, liquid has been spilled or  
objects have fallen into the apparatus, the apparatus has been  
exposed to rain or moisture, does not operate normally, or has been  
dropped.  
14. CAUTION - THESE SERVICING INSTRUCTIONS ARE FOR USE  
BY QUALIFIED SERVICE PERSONNEL ONLY. TO REDUCE THE  
RISK OF ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING  
OTHER THAN THAT CONTAINED IN THE OPERATING  
INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO SO.  
15. Use Certified/Listed Class 2 power supply transformer only.  
IV  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
Chapter 1 — Introduction ..............................................................1  
1.1 Features..............................................................................................1  
Chapter 2 — Installation and Configuration ..................................3  
2.1 Package Contents ..............................................................................3  
2.2 Basic Configuration Of Fastrax II E Dome Camera System ...............4  
2.3 Setting Dome Camera Termination.....................................................5  
2.4 Setting Dome Camera Address(Id)....................................................7  
2.5 Setting Dome Camera Protocol..........................................................8  
2.6 Connection .........................................................................................9  
Connecting to the RS-485 ........................................................................................9  
Connecting to the Monitor ........................................................................................9  
Connecting Alarms ...................................................................................................9  
Connecting the Power ..............................................................................................9  
2.7 Getting Started....................................................................................9  
Chapter 3 — Program and Operation ......................................... 11  
3.1 Selecting Dome Camera...................................................................11  
3.2 Accessing On-Screen Menu Utility ...................................................11  
3.3 How To Control On-Screen Menu Utility ...........................................12  
3.4 Auto Scan .........................................................................................12  
3.5 Preset ...............................................................................................14  
3.6 Shortcut Preset Program ..................................................................15  
V
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.7 Tour ..................................................................................................15  
3.8 Pattern ..............................................................................................17  
3.9 Alarm.................................................................................................18  
3.10 Area Title.........................................................................................18  
3.11 Privacy Zone...................................................................................19  
3.12 Camera –HID2404SXEXXX MODEL ...................................................21  
Focus Control.........................................................................................................21  
WB(White Balance) Control....................................................................................22  
AE Control..............................................................................................................22  
Line Lock Control ...................................................................................................23  
Night Shot Menu.....................................................................................................23  
3.13 Camera –HID2404HCEXXX MODEL....................................................24  
Focus Control.........................................................................................................24  
WB(White Balance) Control....................................................................................24  
AE Control..............................................................................................................25  
Line Lock Control ...................................................................................................26  
Night Shot Menu.....................................................................................................26  
3.14 Dome Setup....................................................................................27  
Home Function Setup.............................................................................................27  
OSD Display Setup.................................................................................................28  
View Direction ........................................................................................................28  
Dome OSD Display ................................................................................................28  
Area Display...........................................................................................................28  
View Angle Setup ...................................................................................................28  
Panning Range.......................................................................................................29  
Flip..........................................................................................................................29  
Tilt Over Angle........................................................................................................29  
Initialize Data..........................................................................................................30  
Origin Offset ...........................................................................................................30  
VI  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dome Reset ...........................................................................................................30  
System Information ................................................................................................30  
Appendix A — Specifications.......................................................31  
Appendix B — Troubleshooting...................................................34  
Appendix C — Glossary..............................................................35  
Appendix D — Short Cut Key......................................................38  
VII  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1 — Introduction  
1.1 Features  
The Fastrax II E dome camera and the Fastrax II Keyboard Controller make up the building  
blocks for any surveillance/security system. Using multiple Keyboard Controllers and multiple  
dome cameras, no place is too large for monitoring. Extensible and flexible architecture  
facilitates remote control functions for a variety of external switching devices such as  
multiplexers and DVRs.  
Built-in 18x(23x,25x) times optical power zoom camera with True Night Shot function  
240 Preset positions.  
8 Tours consist of Preset, Pattern, Auto-Scan and other Tours can be programmed with over  
300 functions and Preset location. While moving, each Preset scan can be watched in  
smooth Vector Scan mode.  
8 Auto Scans including vector scan  
4 Patterns (240second)  
8 Privacy zones  
8 Alarm inputs / 4 Aux outs (NC & NO)  
Variable speed from 0.1°/sec to 90°/sec.  
Turbo speed is Max 360°/sec with Ctrl key pressed.  
Pan / Tilt speed is inversely proportional to the zoom ratio.  
Maximum speed is 380°/sec when preset command.  
Programmable user preferences (alarm, preset, title, etc.).  
Up to 999 selectable camera addresses (Optional 3999 : HID2404CE/CZ/CL ONLY)  
Built-in RS-485/422 receiver driver.  
Built-in power-line surge protection and lightning protection  
Clear bubble with black liner (shelter) for concealing the camera.  
Optional Tinted Bubble, Indoor & Outdoor pendant housing with heater & blower, Indoor Flush  
Mount, Parapet mount & Roof Top mount.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
UP TO 255 MULTIPLEXER  
Alarm Input  
UP TO 8  
<Sensor>  
UP TO 99 DVR  
<Siren>  
Alarm  
Output  
UP TO 4  
<Flashing Light>  
UP TO 32 CAMERA  
J-box  
Master Keyboard  
Figure 1 – Typical System Configuration  
push  
bubble ring ass'y  
remove camera window  
screw  
push  
remove window  
assemble bubble ring ass'y  
Figure 2 – Assemble bubble ring ass’y  
Note : It is recommended to remove camera window for improving picture quality when you use  
bubble ring ass’y.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 — Installation and Configuration  
2.1 Package Contents  
The package contains the following.  
Fastrax II E (Dome Camera)  
Bubble Ring  
Instruction Manual (This Document)  
Assembly Screws for Attaching Fastrax II E  
Plastic Anchor  
………………………1  
………………………1  
………………………1  
………………………3  
………………………3  
………………………1  
………………………2  
10Pin Connector  
12Pin Connector  
CAUTION: Be sure to have caution labels(E version only) on both the body and the base  
of the camera. Different version will not support input and output.  
The dome camera is for use in surface mounting applications and the mounting surface should  
be capable of supporting loads up to 10lb (4.5 kg).  
The dome camera’s base should be attached to a structural object, such as hard wood, wall stud  
or ceiling rafter that supports the weight of the dome camera.  
CABLE ENTRY  
SURFACE(CEILING)  
Unlock  
Lock  
BASE  
Align extruded tap in the base to  
the Keyhole on the pcb in the body  
Lock  
BODY  
Figure 3 – Installation  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.2 Basic Configuration of Fastrax II E Dome Camera System.  
POWER  
AC 24V  
STP AWG # 22  
SIREN  
POWER  
AC 24V  
RS-485  
HALF DUPLEX MODE : RX+,RX-  
LIGHT  
ALARM OUTPUT  
UP TO 4  
SENSOR  
ALARM INPUT  
UP TO 8  
A L 1  
A L 2  
G N  
5
6
A L  
A L  
G N  
A L  
A L  
G N  
D
7
D
D
A L 3  
A L 4  
G N  
ALARM INPUT  
5~8  
ALARM INPUT  
1~4  
8
BNC  
D
1 M C O  
3 M C O  
N C 3  
N O  
4 M C O  
N C 4  
N O  
1
1
N C  
N O  
3
ALARM OUTPUT  
1~2  
2 M C O  
ALARM OUTPUT  
3~4  
2
2
N C  
N O  
(RS-422)  
4
MONITOR  
RS-422  
SIMPLEX MODE : (RX+),(RX-)  
DUPLEX MODE : (TX+),(TX-),(RX+),(RX-)  
BNC  
Figure 4– Basic installation diagram  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
The dome camera must be installed by qualified service personnel in accordance with all local  
and federal electrical and building codes. The system should be installed according to Figures 4  
through 9.  
Termination Switches  
SW1  
ON KSD02H  
9A 1  
2
Address(ID) and Protocol  
selection Switches  
7
9
S3  
S2  
S1  
S6  
S5  
S4  
4
2
7
9
2
4
7
9
2
4
Figure 5– Layout of Switches  
2.3 Setting Dome Camera Termination  
The device which is connected at end of line, whether it be a dome camera or keyboard  
controller, must have the cable for communication terminated by setting the appropriate DIP  
switch. Without proper termination, there is potential for control signal errors. Total length of the  
cable for communication should not exceed 1.2Km.  
SW1  
SW1  
1
2
ON KS D02H  
Terminated  
Not terminated  
ON  
OFF  
ON  
OFF  
2
9A 1  
Figure 6– Setting Dome Camera Termination  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 7- Termination Diagram  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.4 Setting Dome Camera Address (ID)  
To prevent damage, each dome camera must have a unique address (ID). When installing  
multiple dome cameras using a multiplexer, it is suggested that the dome camera address match  
the multiplexer port number.  
If you want to set the address more than 999, you should contact the service provider.  
Example: Port 1 = Dome 1, Port 2 = Dome 2 … Port 16 = Dome 16. If more than 16 dome  
cameras are installed using two or more multiplexers, ID of the dome camera should be ID of  
MUX x No. of camera IN. (e.g. multiplexer ID= n, Camera IN= m then ID of Dome =16x(n-1)+m )  
Refer to Figures 4-5 for setting the dome camera address (ID) and protocol selection.  
S3  
DOME ID  
S3  
0
S2  
0
S1  
1
1
2
S2  
S1  
0
0
2
.
.
.
.
999  
9
9
9
Figure 8– Setting Dome Camera Address (ID)  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.5 Setting Dome Camera Protocol  
If a dome camera is to be installed with a Fastrax keyboard controller, select F2 protocol.  
Consult service personnel if a dome camera is installed with device other than a keyboard  
controller.  
S/W  
S4-1 Enable  
On  
Off  
Disable  
NTSC  
FUNCTION  
Alarm  
NTSC/PAL  
Reserved  
NTSC  
PAL  
D1  
D2  
D3  
D4  
S4-2  
S4-3  
PAL  
S4  
S4  
S4-4 RS-422  
RS-485  
RS-422/RS-485  
D5  
S5-1  
D6  
D7  
PROTOCOL  
S5-2 S5-3  
F2,F2E,P,D,E & Ph Protocol  
(Default)  
Off  
Off  
Off  
Camera  
S6  
S5  
S4  
Off  
Off  
Off  
On  
On  
On  
On  
Off  
On  
On  
Off  
Off  
On  
On  
On  
Off  
On  
Off  
On  
Off  
On  
Reserved  
S 422  
Reserved  
V Protocol  
Reserved  
Baud rate  
D Color  
Reserved  
Protocol  
RS-422/  
RS-485  
D8  
D9  
D10  
BAUD RATE  
S5-4 S6-1 S6-2  
NTSC/PAL  
Alarm  
Off  
Off  
Off  
Off  
On  
On  
On  
On  
Off  
Off  
On  
On  
Off  
Off  
On  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
On  
2400 bps  
4800 bps  
9600 bps (Default)  
19200 bps  
38400 bps  
57600 bps  
115200 bps  
230400 bps  
D11  
D12  
CAMERA  
S6-3  
Off  
Off  
S6-4  
Off  
On  
Default cameras (Default)  
Reserved  
On  
Off  
Reserved  
On  
On  
Reserved  
Figure 9– Protocol Selection Switches  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.6 Connections  
• Connecting to the RS485/ 422  
The dome camera can be controlled remotely by an external device or control system, such as a  
control keyboard, using RS485 half-duplex , RS422 duplex or simplex serial communications  
signals. Connect Marked Rx+, Rx- to Tx+ and Tx- of the RS485 control system.  
If control system is RS422, connect Rx+(Tx+), Rx+(Tx-) and Rx+, Rx- of the dome camera to  
Tx+, Tx- and Rx+, Rx- of the control device respectively.  
Connecting Video out connector  
Connect the video out(BNC) connector to the monitor or video input.  
• Connecting Alarms  
AL1 to 8 (Alarm In)  
You can use external devices to signal the dome camera to react on events. Mechanical or  
electrical switches can be wired to the AL (Alarm In) and GND (Ground) connectors.. See  
Chapter 3 — Program and Operation for configuring alarm input.  
GND (Ground)  
NOTE: All the connectors marked GND are common.  
Connect the ground side of the Alarm input and/or alarm output to the GND connector.  
NC(NO)1 TO 4 (Normal Close or Normal Open : Alarm Out)  
The dome camera can activate external devices such as buzzers or lights. Connect the device to  
the NC(NO) (Alarm Out) and COM (Common) connectors. See Chapter 3 — Program and  
Operation for configuring alarm output.  
• Connecting the Power  
Connect the power of AC 24V 850mA to the dome camera.  
Use certified / Listed Class 2 power supply transformer only.  
2.7 Getting Started  
Once installed apply power to the dome camera. The dome camera will start a configuration  
sequence. When configuration is done, the following information is displayed on the keyboard  
controller’s LCD  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
RAM TEST  
CHECK NO. : OK!  
CHECK AAAA : OK!  
CHECK 5555 : OK!  
FASTRAX II E Vx.xxx  
CAMERA TYPE xxxx  
WAIT DOME SETTING.  
INIT TILT ORGIN SET OK  
INIT PAN ORGIN SET OK  
INIT CAMERA SET OK  
PRESET No.  
CAMERA TITLE  
CAMERA ID  
001 PRESET  
PRESET TITLE  
or AREA TITLE  
INFORMATION  
DISPLAY  
FUNCTION  
UNDER RUNNING  
T001  
ALARM:1  
DOMEID:0001  
W360.0,090.0  
PAN & TILT ANGLE  
VIEW DIRECTION  
ALARM DISPLAY  
OSD Position  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3 — Program and Operation  
3.1 Dome Camera Selection  
Before you program or operate a dome camera, you must select the dome camera by pressing  
the dome camera No. + CAM  
Example: Pressing 1 , 0 and CAM key sequentially will select dome camera 10. The selected  
dome camera ID will be displayed on the LCD monitor of the keyboard controller.  
3.2 Accessing the On-Screen Menu Utility  
You can call up the On-screen menu utility on your monitor by pressing MENU key on the  
keyboard controller, the following On-screen menu utility will appear:  
MAIN MENU  
AUTO SCAN  
PRESET  
TOUR  
PATTERN  
ALARM  
AREA TITLE  
PRIVACY ZONE  
CAMERA  
DOME SETUP  
EXIT(ESC TO EXIT)  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.3 How to control the On-Screen Menu Utility  
Action  
Function  
MENU  
Call the On-screen menu utility  
Go into the sub-menu items.  
Execute the command(exit)  
Change value.  
Joystick left or right  
Navigate through the menu items.  
Joystick up or down  
Joystick down  
Navigate through the menu items.  
Finish editing title.  
Change value.  
Enter editing title mode.  
Zoom handle twist  
CTRL + Joystick  
ESC  
Change value of angle  
Escape (EXIT)  
3.4 Auto Scan (First Item of the Main menu / Shortcut: SCAN)  
The Auto scan supports up to 8 programmed angles at user-programmable speeds. Follow  
these steps to program Auto Scan:  
AUTO SCAN SETUP  
SCAN 01  
: AUTOSCAN01  
SPEED(MODE) : FAST VECTOR  
START ANGLE : 127.1, 027.7 X7  
END ANGLE : 157.7, 080.7 X13  
SCAN DIR. : CCW  
SWAP  
: OFF  
SAVE AND EXIT (ESC TO CANCEL)  
HOLD DOWN CTRL KEY  
WHILE SELECT POSITION.  
SPEED(MODE) :  
NORMAL1~NOMAL9,SLOW VECTOR,FAST VECTOR  
NORMAL1 (SLOWER) NORMAL9 ( FASTER)  
SLOW VECTOR, FAST VECTOR : Move from start point to end point  
including tilt and zoom simultaneously and linearly. In case of  
HID2404HCExxx model, zoom is fixed at more wide angle and the zoom  
magnification information is not displayed.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Press the SCAN key to enter Auto Scan menu directly. Or press the MENU key to display the  
main menu on the monitor. Scroll to Auto Scan and push the Joystick to the right.  
2. Select an Auto Scan number by pushing the Joystick left or right.  
3. Twist the Joystick to enter the title by scrolling through the alphanumeric characters and  
pushing the handle to the right or left to move to the next space. Press ENTR key or push the  
Joystick down to finish title mode.  
4. When finish entering the title, select “START ANGLE” with the Joystick. Hold down the  
CTRL/PGM key while selecting the start position using the Joystick. Current panning  
position will be displayed. Release CTRL/PGM key to complete the selection of the start  
position.  
5. Push the Joystick downward to select “END ANGLE.” Hold down the CTRL/PGM key while  
moving the Joystick to select the end position. The end position angle should be larger than  
start position. Release the CTRL/PGM key to complete the selection of the end position.  
6. Push the Joystick downward to select “Tilt & Zoom.” Set the zoom and tilt angle by holding  
down the CTRL/PGM key.  
7. Push the Joystick downward to select “Speed” and set the speed by twisting the Joystick  
clockwise or counterclockwise (HID2404CZ) or moving the Joystick left and  
right(HID2404CL) to select the auto scan speed.  
8. Select Save and Exit by pushing the Joystick to the right. Press ESC to exit the program  
without saving.  
Pressing the HOME key delete stored data and display 000 angle immediately.  
NOTE: Using the Tour mode in conjunction with preset and Auto Scan, you can make the camera  
travel from one preset position to another preset position at a specific speed. (Pan only)  
a. Before entering the Auto Scan menu, select a preset position as a starting point for Auto Scan.  
Example: 2 + PRST and do step 1 to 4. Instead of step 5, just press the Ctrl/PGM key at the  
start angle position, the current position will be displayed as a start position.  
b. Save and exit from the menu.  
c. In normal mode, call a preset to be the end point of scan. Press 3 + PRST then press Scan  
key to enter the Auto Scan menu. Move the cursor position to END ANGLE. Just press  
CTRL/PGM key at the end angle position. Do steps 7 to 9.  
Example: Preset 001>002>003>004>005>006, Auto Scan 01 starts at 002, ends at 003,  
Auto Scan 02 starts at 005, ends at 006. Tour 001, 002, A01, 004, A02.  
1 Î 2 2~3 Î 4 Î 5~6 Î1 Î 2 2~3 ……  
Where Î : Quick move, ~ : Programmed speed by Auto Scan.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.5 Preset (Second Item of the Main menu / Shortcut: PRST)  
If you need to view specific places routinely, you should program presets. A preset is a  
programmed video scene with automatic pan, tilt, zoom, focus and iris settings. Once  
programmed, entering the number and pressing a Preset button on your controller automatically  
calls up the preset. In addition, presets may be assigned to alarm actions or as the “home”  
position for the dome camera. As many as 240 presets, whose positions are saved in the  
dome’s firmware, may be programmed.  
There are three pages of preset menu, each page can hold 80 presets. Pages can be scrolled  
by pushing the Joystick to the Left or Right on the first or last No. of Preset.  
PRESET SETUP  
NO. 001: xxxxxxxxxxxxxxxx  
FOCUS : AUTO (MANUAL)  
IRIS : AUTO (MANUAL)  
DWELL : 03 SEC(0~99)  
1234567890 1234567890  
00***======01==========  
02==========03==========  
04==========05==========  
06==========07==========  
JOY-LEFT TO PREV. PAGE  
SAVE AND EXIT(ESC TO CANCEL)  
x : 16 digits of title for preset label  
= : blank preset position  
*
: position has the preset  
: Current cursor position  
Follow steps below to store the Preset positions:  
1. Press MENU to display the main menu. Select the Preset option by using the Joystick to the  
right. (Press Prst to go directly to the Preset menu without going through the main menu.)  
2. Select the blank preset position to be stored by pushing the Joystick up, down, right, or left.  
3. The position, which is marked with , already has the preset view assigned. To review the  
stored preset, press Prst key on the ★ ,The camera will show the stored preset view.  
4. After selecting a blank position, press and hold CTRL/PGM, Use the Joystick to control the  
direction of the camera and lens.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. After aiming the camera (view direction and lens control), release CTRL/PGM. Then twist the  
Joystick handle or Press Tele or Wide Key to store the selected view. The position number  
will be displayed and the user will be prompted to enter a preset title.  
6. Enter the title for the preset position using the Joystick. (Rotate handle clockwise and  
counterclockwise or press Tele or Wide Key to scroll through the alphanumeric characters,  
push the handle to right or left to select next or previous digit.)  
7. When you are finished entering the title, push the Joystick downward. Set the focus by  
pushing the Joystick to the right or left. Set the IRIS value in the same manner as the focus.  
8. Move to the DWELL setting by pushing the Joystick down. Twist the Joystick clockwise or  
counterclockwise to increase or decrease dwell time of the preset position.  
9. To select the next page of presets, scroll the page by pushing the Joystick to the Left on the  
first and last columns of the menu.  
10. Repeat steps 2 through 7 for each additional preset position.  
11. To edit the title of a stored preset, use the Joystick to position the cursor on the desired  
preset position. Press the Prst key to recall the stored preset. Twist the zoom handle  
clockwise to enter the preset title, focus and IRIS. Preset titles are useful with short cut  
preset programming. Refer to Shortcut programming below.  
12. Select Save and Exit by pushing the Joystick to the right. Press ESC to exit the Preset menu  
without saving.  
NOTE: Press the Home key at programmed position to delete a programmed preset view.  
3.6 Shortcut of Preset Program.  
Select a view to be stored (direction of the camera, zoom and focus), then press No. (1 to 240),  
and then press PGM, PRST subsequently. The current view will be stored to the selected preset  
number if position is empty. If selected preset number is not empty, “PRESET EXISTING”  
message will be displayed on the monitor and be prompted to overwrite.  
Example: 1 , 0 , 1 + PGM + PRST will store current view as preset No. 101. In this case, focus  
and Iris mode will be programmed as Auto, dwell time will be set to 3 sec.  
3.7 Tour (THIRD ITEM OF THE MAIN MENU / SHORTCUT: TOUR)  
There are 8 programmable Tours. Each Tour consists of up to 42 Preset positions, Patterns,  
Scans or other Tours (second-level). Using second-level Tours, it can be expanded to over 300  
functions in a single Tour. However second level Tours will be ignored when called by a Tours.  
The following example illustrates this concept:  
If  
Tour1 has Preset1ÎPreset2ÎTour2ÎTour3 and  
Tour2 has Preset3ÎPreset4ÎTour4ÎPreset5 and  
Tour3 has Preset6ÎPattern 1and  
Tour4 has Preset7.  
Tour1 executes as follows:  
Preset1 Î Preset2 Î Preset3 Î Preset4 Î Preset5 Î Preset6 Î Pattern1 Î  
Preset1 Î ... (Repeat)  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Tour2 executes as follows:  
Preset3 Î Preset4 Î Preset7 Î Preset5 Î Preset1 … Repeat  
(Tour4 is still valid if called directly from Tour2.)  
TOUR 01:xxxxxxxxxxxxxxxx  
SCAN TYPE:NORMAL  
=== === 003 === === === ===  
A08 === === === === === ===  
=== T02 === 001 === === ===  
=== === === T08 === === ===  
=== === === === === === ===  
=== === === === === === ===  
SAVE AND EXIT(ESC TO CANCEL)  
PRESS FUNCTION KEY AND ROTATE  
JOYSTICK TO SELECT NUMBER.  
xxxxx  
===  
SCAN TYPE  
DWELL  
003  
: 16 digits of title for tour label  
: blank preset position  
: Max (Normal)/ Slow V. Scan/ Fast V. Scan  
: 03-99 Sec  
: Preset 003 (1~240)  
A08  
: Auto Scan 08 (1~8)  
P01  
: Pattern 01 (1~4)  
T02  
: Tour 02  
(1~8)  
Follow the steps below to program the Tours:  
1. Press MENU to display the main menu on the monitor. Scroll to Tour and push the  
Joystick to the right to enter the Tour menu. Or just press the Tour key on the keyboard  
2. Choose an empty location to be programmed by pushing the Joystick up, down, right, or  
left.  
3. To see a stored preset view, use the Joystick to move the cursor to a stored position. By  
pressing Prst key, the camera will move to the stored Preset view.  
4. To add a stored preset as a Tour, twist the Zoom handle or press Zoom Key (Programmed  
preset will scroll). To remove a stored preset from the Tour, press the Home key, blank  
position mark (===) will be displayed. You can overwrite the programmed position.  
5. To place functions other than preset, press Tour, Ptrn, or Scan for Tour, Pattern or Auto  
Scan respectively.  
6. Repeat Step 2 through 5 for each desired position. Each title will be displayed on top of the  
line.  
7. Up to 36 Presets, Tours, Patterns Scans can be selected for a Tour. You can expand the  
Tour sequence by calling other programmed tours. Push the Joystick handle to right or left  
while the cursor is on the top of the line (TOUR 01) to select another page of the Tour menu.  
(TOUR 01)  
8. You can enter a title for the selected Tour by twisting the Joystick while the cursor is on  
the top of the line (TOUR 01). Rotate the handle clockwise or counterclockwise to scroll  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
through the alphanumeric characters. Push the handle to the right or left to select the next  
or previous digit.  
9. Select Save and Exit by pushing the Joystick to the right. Press ESC to exit the program  
without saving.  
NOTE: Press the Home key at a programmed position to delete programmed function.  
In the Tour mode, in conjunction with preset and Auto Scan, you can make the camera  
travel from a preset position to another preset position at a specific speed.  
Example: Preset 001>002>003>004>005>006, Auto Scan 01 starts at preset 002, ends at  
preset 003, Auto Scan 02 starts at preset 005, ends at preset 006; Tour 001, 002, A01, 004,  
A02.  
1 Î 2 2~3 Î 4 Î 5~6, repeat  
where Î : Quick move, ~ : Programmed speed  
3.8 Pattern (Fourth 4 Item of the Main menu / Shortcut: PTRN)  
The Pattern feature records user control of the selected dome camera for up to 240 seconds. Up  
to four 4 patterns can be stored and played back by pressing No.+ PTRN keys subsequently.  
PATTERN SETUP  
NO.  
TITLE  
SEC  
01 : xxxxxxxxxxxxxxxx 000  
02 : xxxxxxxxxxxxxxxx 041  
03 : xxxxxxxxxxxxxxxx 010  
04 : xxxxxxxxxxxxxxxx 020  
TOTAL  
071  
SAVE AND EXIT(ESC TO CANCEL)  
HOLD DOWN CTRL KEY  
WHILE RECORDING.  
Follow steps below to program the Pattern:  
1. Press MENU key to display the main menu on the monitor.  
2. Scroll down to PATTERN and push the Joystick to the right. Or simply press the PTRN  
key rather than use the Main Menu.  
3. Select the empty Pattern number to be programmed by pushing the Joystick Up or Down.  
If last column is not 000, a pattern has already been recorded. Patterns can be over written.  
4. Press and hold down the CTRL/PGM key while controlling the camera direction and zoom  
with the Joystick. Your controls will be automatically recorded until you release the  
CTRL/PGM key. You can repeat this procedure until you have the pattern you want.  
Previously recorded patterns will be overwritten each time you do this.  
5. Scroll down to the Save and Exit option and push the Joystick to the right to save and exit.  
6. You can title the selected Pattern by twisting the Joystick. Rotate the handle clockwise or  
counterclockwise to scroll through the alphanumeric characters, push the handle to right or  
left to select next or previous space.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. Pressing ESC will not save your information and exits to the previous mode.  
Press the HOME key at any programmed position to delete that programmed pattern.  
NOTE: If total recording time reaches 240 seconds, it will automatically stop for a moment and  
restart recording. Previous data will be overwritten.  
3.9 Alarm (This menu shows on only specific model, Fifth Item of Main menu)  
ALARM SETUP  
NO PRI PRS IN OUT HLD LATCH  
01 1 001 OFF OFF 3 OFF  
02 0 A01 OFF OUT1 3 OFF  
03 1 240 NO OUT1 3 OFF  
04 2 001 NC OUT4 3 OFF  
05 1 001 OFF OFF 3 OFF  
06 8 001 OFF OUT1 3 OFF  
07 1 240 NO OUT1 3 OFF  
08 2 001 NC OUT4 3 OFF  
SAVE AND EXIT(ESC TO CANCEL)  
NO  
: Alarm input number  
PRIO : Lower No. has higher priority, Equal priority alarms will be serviced repeatedly.  
PRS  
IN  
OUT  
: Stored preset number to be called by alarm.  
: NO/NC - normally open /Closed OFF - ignore  
: OUT1~OUT4 - Relay out 1,2,3,4, OFF - No output.  
HOLD : Alarm will be held for programmed time (01 to 99 seconds)  
LATCH : ON - Shows all alarms including past alarm, OFF - Shows activated alarms only.  
There are 8 levels of priority. “0” is the highest priority and can be choosed Autoscan, Pattern or  
Tour. During responding “0” priority alarm, other alarms won’t be serviced until the “0” priority  
action is completed.  
1. Press Menu to display the main menu on the monitor. Select the Alarm option by pushing  
the Joystick up or down and push to right to enter the detail menu.  
2. Select the alarm input number by pushing the Joystick up or down and select the column  
you wish to setup. Selected position will be highlighted.  
3. Select the Preset, Status of Input (NC/NO/OFF), and Output (OUT1~4/OFF) by pushing the  
Joystick to the right or to the left.  
4. To increase or decrease the preset number or to change the status or output number, twist  
the Joystick clockwise or counterclockwise. In case of preset, programmed preset number  
will be scrolled.  
5. Select the Save and Exit option by pushing the Joystick up or down. Save and exit the  
program by pushing the Joystick to the right. Press ESC to exit the program without saving.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.10 Area Title (Sixth Item of Main menu)  
Enter a specific name on programmed angle between START and END. For the screen below,  
when the camera points at an angle between 124.3° to 359.5°, ABC will be displayed on the  
screen.  
AREA TITLE SETUP  
NO  
01 ABC  
TITLE  
START END  
124.3 359.5  
02 xxxxxxxxxxxxxxxx ===== =====  
03 xxxxxxxxxxxxxxxx ===== =====  
04 xxxxxxxxxxxxxxxx ===== =====  
05 xxxxxxxxxxxxxxxx ===== =====  
06 xxxxxxxxxxxxxxxx ===== =====  
07 xxxxxxxxxxxxxxxx ===== =====  
08 xxxxxxxxxxxxxxxx ===== =====  
SAVE AND EXIT(ESC TO CANCEL)  
HOLD DOWN CTRL KEY TO MOVE  
PAINNING AND SET AREA ANGLE.  
Pages can be scrolled through by pushing the Joystick to the Left or Right on the first or last  
column of the menu. Pushing the Joystick to left on the “NO” column (01 ~ 08) of the menu to  
scroll to the previous page. Push the Joystick to right on the “END” column to go to the next  
page.  
1. Press MENU to display the main menu on the monitor. Select the Area Title option by  
pushing the Joystick up or down and push to right to enter the detail menu.  
2. Select the area number by pushing the Joystick up or down. Select Start, End or number  
column to be set by pushing the handle to the right or left. The selected column will be  
highlighted.  
3. To enter area title, select the number column and rotate the handle clockwise or  
counterclockwise. You can select alphanumeric characters by rotating the handle. Move to  
the next character by pushing the Joystick to the right. To finish entering the title, push the  
Joystick down.  
4. To adjust panning limit, press the CTRL/PGM key and hold down. Then use the Joystick  
to go the desired direction. The end limit must be in an increasing direction. (Start < End).  
5. When you press the CTRL/PGM key, the current position of the pan will be printed in the  
highlighted column. With this feature, you can easily set the next start point as the previous  
end point.  
6. Select the Save and Exit option by pushing the Joystick up or down. Save and exit the  
program by pushing the Joystick to the right. Press ESC to exit the program without saving.  
Pressing the HOME key will delete programmed data. (Angles will be turned ====  
immediately.)  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.11 Privacy Zone (Seventh Item of Main menu)  
Hide up to 8 unwanted views in a camera.  
PRIVACY ZONE SETUP  
NO  
TITLE  
METHOD  
01 xxxxxxxxxxxxxxxx ON BLOCK  
02 xxxxxxxxxxxxxxxx OFF V.OFF  
03 xxxxxxxxxxxxxxxx NONE ====  
04 xxxxxxxxxxxxxxxx NONE ====  
05 xxxxxxxxxxxxxxxx NONE ====  
06 xxxxxxxxxxxxxxxx NONE ====  
07 xxxxxxxxxxxxxxxx NONE ====  
08 xxxxxxxxxxxxxxxx NONE ====  
SAVE AND EXIT(ESC TO CANCEL)  
1. Press MENU to display the main menu on the monitor. Select the Privacy Zone option by  
pushing Joystick Up or Down and push to right to enter the detail menu.  
2. Select the privacy zone number by pushing the Joystick up or down.  
3. To enter the zone name, rotate the handle clockwise or counterclockwise. You can select  
alphanumeric characters by rotating the handle. Move to the next character position by  
pushing the Joystick to the right. To finish entering the title, push the Joystick down or  
press the ENTR key.  
4. To adjust the “marked” (privacy) area, press and hold down the CTRL/PGM key and then  
use the Joystick (direction and zoom) until you get desired view. Release the key, the right  
column will be set to ON.  
5. You can overwrite an existing zone. Use the Home key to delete the marked zone, or push  
the Joystick to the right or left to turn the stored zone On or Off.  
6. Select the Save and Exit option by pushing the Joystick up or down. Save and exit the  
program by pushing the Joystick to the right. Press ESC to exit the program without saving.  
Press the HOME key to delete programmed privacy zone.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.12 Camera (Eighth Item of Main menu) – HID2404SxExxx MODEL  
NOTE: The menu features will vary depending on the camera module installed in your dome  
camera.  
CAMERA SETUP  
FOCUS CONTROL  
WB CONTROL  
AE CONTROL  
LINE LOCK CONTROL  
SHARPNESS  
BACK LIGHT  
: 9  
: OFF  
DIGITAL ZOOM : OFF (2X/4X/MAX)  
NIGHT SHOT CONTROL (optional)  
SAVE AND EXIT(ESC TO CANCEL)  
SHARPNESS  
BACK LIGHT  
Digital ZOOM  
The higher the value,the more edges in the picture will be enhanced(0~15)  
Objects in front of bright backgrounds will be clearer with BLC ON.  
OFF : Zoom range is limited to the optical.  
2x : Zoom is extendable up to 2x of digital range.  
4x : Zoom is extendable up to 4x of digital range.  
MAX: Zoom is extendable Max digital zoom range.  
•FOCUS CONTROL  
FOCUS SETUP  
MODE  
: AUTO  
AF SENSITIVITY : HIGH  
SAVE AND EXIT(ESC TO EXIT)  
MODE : AUTO / MANUAL  
Use manual mode in normal use.  
AF SENSITVITY : HIGH / LOW  
HIGH: Use this option when shooting fast motion.  
LOW: Offers better focus stability. In low luminance conditions, Auto Focus stops  
operation even when brightness changes, enabling stable images of moving  
objects.  
CAUTION: Avoid continuous, 24-hour use of the auto focus. This will shorten the  
lifespan of the lens.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
• WB (white balance) CONTROL  
WB SETUP  
MODE :  
R GAIN :  
B GAIN :  
AUTO  
210  
155  
EXIT(ESC TO EXIT)  
MODE  
RGAIN  
BGAIN  
MANUAL / AUTO / INDOOR / OUTDOOR / ONE PUSH / ATW  
0 ~ 255  
0 ~ 255  
Use the ATW mode for normal use.  
RGAIN / BGAIN modes are controllable only in MANUAL Mode  
Push the Joystick to the right or left to change.  
NOTE : “ONE PUSH” means that when rotating the Joystick handle for a moment the lens moves  
to adjust the focus for the subject. The focus lens then holds that position until the Joystick  
handle rotation.  
• AE CONTROL  
AE SETUP  
MODE  
: FULL AUTO  
SLOW SHUTTER : AUTO  
IRIS  
GAIN  
BRIGHT  
SHUTTER  
: F2.4  
: 0 DB  
: 14  
: 1/60  
SAVE AND EXIT(ESC TO CANCEL)  
MODE  
FULL AUTO / MANUAL / SHUTTER PRIO / IRIS PRIO / BRIGHT  
SLOW SHUTTER AUTO / MANUAL ----- AUTO effect only FULL AUTO mode  
IRIS  
CLOSE / F22 / F19 / F16 / F14 / F11 / F9.6 / F8.0 / F6.8 / F5.6 / F4.8 /  
F4.0 / F3.4 / F2.8 / F2.4 / F2.0 / F1.6 / F1.4  
0 / 2 / 4 / 6 …… / 28 / -3 DB  
GAIN  
BRIGHT  
SHUTTER  
0, 2, 3, 4 ..... 29, 30  
1/1 , 1/2 , 1/4(3), 1/8(6). .. 1/4000, 1/6000, 1/10000  
SAVE AND EXIT (ESC TO CANCEL)  
NOTE : Values in ( ) are for PAL Camera.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
• LINE LOCK CONTROL  
LINE LOCK SETUP  
MODE : INTERNAL  
PHASE : 125  
EXIT(ESC TO EXIT)  
MODE  
PHASE  
INTERNAL / EXTERNAL Adjusts phase of picture with other  
0~255 cameras in EXTERNAL mode.  
EXIT (ESC TO EXIT)  
• NIGHT SHOT MENU  
The NIGHT SHOT option removes the IR cutoff filter of the camera and makes the camera  
sensitive to near infrared. The picture will appear greenish. This may be suppressed by setting  
the BLACK & WHITE option to ON.  
The operator can enable NIGHT SHOT for all dome cameras at the same time.  
If the NIGHT SHOT mode is set to GLOBAL, “999” + ENTR/GLBL will turn Off the NIGHT SHOT  
mode  
“888” + ENTR/GLBL will turn On the NIGHT SHOT mode.  
NIGHT SHOT SETUP  
MODE  
LOCAL CONTROL  
: MANUAL  
: OFF  
EXIT(ESC TO CANCEL)  
MODE  
MANUAL / AUTO / GLOBAL  
AUTO: Camera goes in to B&W mode at low light.  
GLOBAL: Controlled by remote (888+ENTR/GLBL).  
MANUAL CONTROL  
ON / OFF  
MANUAL: ON/OFF will enable and disable Night Shot mode of an individual camera.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.13 Camera (Eighth Item of Main menu) – HID2404HCExxx MODEL  
NOTE: The menu features will vary depending on the camera module installed in your dome  
camera.  
CAMERA SETUP  
FOCUS CONTROL  
WB CONTROL  
AE CONTROL  
LINE LOCK CONTROL  
SHARPNESS : 32  
BACK LIGHT  
: OFF  
DIGITAL ZOOM : OFF (2X,4X,MAX)  
NIGHT SHOT CONTROL  
SAVE AND EXIT(ESC TO CANCEL)  
SHARPNESS  
(0~63).  
The higher the value, the more edges in the picture will be enhanced  
BACK LIGHT  
Digital ZOOM  
Objects in front of bright backgrounds will be clearer with BLC ON.  
OFF : Zoom range is limited to the optical.  
2x : Zoom is extendable up to 2x of digital range.  
4x : Zoom is extendable up to 4x of digital range.  
MAX: Zoom is extendable Max digital Zoom range.  
• FOCUS CONTROL  
FOCUS SETUP  
MODE  
: AUTO  
EXIT(ESC TO EXIT)  
MODE : AUTO / MANUAL  
Use manual mode in normal use.  
CAUTION: Avoid continuous, 24-hour use of the auto focus. This will shorten the  
lifespan of the lens.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
• WB (white balance) CONTROL  
WB SETUP  
MODE :  
R GAIN :  
B GAIN :  
AUTO  
133  
133  
EXIT(ESC TO EXIT)  
MODE  
RGAIN  
BGAIN  
MANUAL / AUTO  
0 ~ 255  
0 ~ 255  
Use the AUTO mode for normal use.  
RGAIN / BGAIN modes are controllable only in MANUAL Mode  
Push the Joystick to the right or left to change.  
• AE CONTROL  
AE SETUP  
MODE : AE (DSS)  
SLOW SHUTTER : 1/4  
IRIS  
GAIN  
WDR MODE  
SHUTTER  
: F2.4  
: 0 DB  
: ON  
: AUTO  
SAVE AND EXIT(ESC TO CANCEL)  
MODE  
SHUTTER PRIO / IRIS PRIO / AGC PRIO / AE (DAWN) / AE (DARK)  
AE (DSS)  
AE (DAWN)  
AE (DARK)  
AE (DSS)  
Under the low light condition when night shot mode is AUTO, IR Cut filter  
is automatically turned on and off.  
IR Cut filter is automatically turned on and off more dark condition than  
AE (DAWN)  
Automatic Exposure without switching IR Cut filter  
SLOW SHUTTER OFF , 1/60 , 1/30 , 1/ 15 , 1/8, 1/4, 1/2 ---- AE (DSS) mode only.  
IRIS  
GAIN  
F1.6 / F2.2 / F3.2 / F4.4 / F6.4 / F8.8 / F12 / F17/F24/F34  
0, 6, 12 , 18 , 24 , 30 DB  
WDR MODE  
Wide Dynamic Range Technology uses two shutter speeds in alternative  
video fields-high and normal- every 60th (or 50th) of a second and  
combines two fields into one progressive scan frame. It allows every detail  
to be captured accurately even if one portion of an image is brilliantly  
bright while other portions are dark.  
SHUTTER  
1/2 , 1/4 , 1/8 , 1/15 , 1/30 , 1/60 , 1/120 , 1/180 , 1/250 , 1/500 ,  
1/1000 ,1/2000, 1/4000, 1/10,000 , 1/30,000  
(1/1.5 , 1/3 , 1/6 , 1/12 , 1/25 , 1/50 , 1/100 , 1/150 , 1/250 , 1/500 ,  
1/1000 ,1/2000, 1/4000, 1/10,000 , 1/30,000)  
NOTE : Values in ( ) are for PAL Camera.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
• LINE LOCK CONTROL  
LINE LOCK SETUP  
MODE : INTERNAL  
PHASE : 125  
EXIT(ESC TO EXIT)  
MODE  
PHASE  
INTERNAL / EXTERNAL Adjusts phase of picture with other  
0~255 cameras in EXTERNAL mode.  
EXIT (ESC TO EXIT)  
• NIGHT SHOT MENU  
The NIGHT SHOT option removes the IR cutoff filter of the camera and makes the camera  
sensitive to near infrared. The picture will appear greenish. This may be suppressed by setting  
the BLACK & WHITE option to ON.  
The operator can enable NIGHT SHOT for all dome cameras at the same time.  
If the NIGHT SHOT mode is set to GLOBAL, “999” + ENTR/GLBL will turn Off the NIGHT SHOT  
mode  
“888” + ENTR/GLBL will turn On the NIGHT SHOT mode.  
NIGHT SHOT SETUP  
MODE  
LOCAL CONTROL  
: MANUAL  
: OFF  
EXIT(ESC TO CANCEL)  
MODE  
AUTO / MANUAL / GLOBAL  
AUTO: Camera goes in to B&W mode at low light.  
GLOBAL: Controlled by remote (888+ENTR/GLBL).  
MANUAL CONTROL  
ON / OFF  
MANUAL: ON/OFF will enable and disable Night Shot mode of an individual camera.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.14 Dome Setup (Ninth Item of Main menu)  
CONFIGURATION MENU  
HOME FUNCTION SETUP  
OSD DISPLAY  
VIEW ANGLE SETUP  
INITIALIZE DATA  
ORIGIN OFFSET  
DOME RESET  
SYSTEM INFORMATION  
EXIT(ESC TO EXIT)  
• HOME FUNCTION SETUP  
After a dome control menu item has been selected, follow the directions below to set the function.  
HOME FUNCTION SETUP  
HOME FUNCTION : NONE  
FUNCTION NUMBER : ---  
WATING TIME  
: 120 SEC  
FUNCTION ENABLE : OFF  
SAVE AND EXIT(ESC TO CANCEL)  
HOME FUNCTION  
FUNCTION NUMBER  
WAITING TIME  
: None/ Preset/ Tour/ Pattern/ Auto Scan  
: xxx  
: 10~240 Seconds  
: ON/ OFF  
FUNCTION ENABLE  
The Home function can be set so that the camera automatically goes to Preset, Tour, Pattern,  
Auto Scan after the keyboard controller has been idle for a amount of time. For example, if the  
Joystick controller is idle for 10 seconds, the camera goes to preset 1.  
Follow these steps to program the Home position:  
1. Press MENU to display the main menu on the monitor.  
2. Select Home Function by pushing the Joystick to the right or to the left to scroll through the  
None, Tour, Pattern, Auto Scan and Preset functions.  
3. Select Function Number by pushing the Joystick down, and push the Joystick to the right  
or to the left. The executable function number will scroll. Each function has maximum  
numbers. For example, you can have 240 Presets, 8 Tours, 4 Patterns and 8 Auto Scan  
options.  
4. Select Function Time by pushing the Joystick down. Push the Joystick to the right or to  
the left to select from 10 to 240 seconds.  
5. Select Function Enable by pushing the Joystick down. Turn the Home Enable ON or OFF  
by pushing the Joystick to the right or to the left.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
• OSD DISPLAY  
DISPLAY SETUP  
CAMERA TITLE : DOMEID  
VIEW DIRECTION : OFF  
DOME OSD DISPLAY : ON  
AREA DISPLAY  
: OFF  
SAVE AND EXIT(ESC TO CANCEL)  
CAMERA TITLE  
: 8 CHARACTER CAN BE SET  
: ON / OFF  
: ON / OFF  
VIEW DIRECTION  
DOME OSD DISPLAY  
AREA DISPLAY  
: ON / OFF  
• VIEW DIRECTION  
“ON” sets current direction as N(north) and the coordinate angle to 000. “OFF” hides the  
directional title. Every 90 degrees of clockwise rotation will change the title to E(East), S(South),  
W(West). If using the ON/OFF option frequently, it is recommended that you set “North” as a  
Preset. Recall the “North” Preset before enabling the directional title.  
• DOME OSD DISPLAY  
All display or title will disappear when DOME OSD DISPLAY sets OFF  
• AREA DISPLAY  
If this option is enabled, the nearest area title will be displayed when the camera is moving  
whether by manual operation, Auto Scan, or Pattern. Select ON or OFF by pushing the Joystick  
to the right or to the left. The Dome camera’s OSD will override this function (Dome camera’s  
OSD must be enabled).  
VIEW ANGLE SETUP  
VIEW ANGLE SETUP  
PANNING RANGE  
FLIP  
TILT OVER ANGLE : W/O BUBBLE  
STABILIZER : ON (OFF)  
: ON  
SAVE AND EXIT(ESC TO CANCEL)  
STABILIZER When the Image Stabilizer Function is ON, it helps in obtaining a stable image  
free of vibration caused by jarring movements. For a vibration frequency of  
around 10 Hz, correction is approximately 90%.(HID2404SHE11X model only)  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
• PANNING RANGE  
When the dome camera is installed near a wall, panning range can be limited by user.  
PANNING RANGE SETUP  
RIGHT LIMIT : 000.0  
LEFT LIMIT : 000.0  
ENABLE  
SWAP RIGHT/LEFT  
SAVE AND EXIT(ESC TO CANCEL)  
: OFF  
• FLIP  
Allows the dome camera to automatically turn 180 degrees when the camera tilts to its lower  
position.  
When the camera reaches the floor directly above the moving object, it will stop. Release the  
Joystick handle instantly and then pull down to run the flip function. The tracking speed will be  
the same as previous.  
• TILT OVER ANGLE  
This option is used to set the limit of the horizontal view angle so that the trim ring or ceiling does  
not obstruct the horizontal image when zooming out (wide angle).  
ON: In some installations it is desirable for the dome camera to be able to see above the  
horizon. When this option is chosen, the dome will tilt up over the horizon(About 10  
degrees). When the lens is zoomed out, you can see the ceiling line. But when the lens is  
zoomed in, the viewing angle is narrower, and the ceiling line disappears.  
Without Bubble: The tilt range of the camera is limited to see the horizon so the picture  
shows part of the ceiling line.  
With Bubble: The tilt range of the camera is limited to see below the horizon (- 10 degrees).  
Over Angle is not sufficient enough to avoid ceiling obstructions, please adjust Origin Offset  
of tilt angle as described below.  
• INITIALIZE DATA  
INITIALIZE DATA  
FACTORY DEFAULT  
ERASE PROGRAMMED DATA  
EXIT(ESC TO EXIT)  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Erase all stored data from the Flash-ROM of the selected dome camera. You will be asked to  
enter Yes or No. If you intend to erase all data then press the MENU key, otherwise press the  
ESC key to exit without erasing. The erased data includes all stored data (titles, presets, and  
tours….) except origin offset.  
The offset value is still valid after all data is erased. The offset value can be zeroed only with  
default set of Offset origin menu.  
CAUTION: All the data in the selected dome camera will be lost unless you download the  
data into a safe place. (Refer to Download/ Upload data function in the  
Keyboard Configuration utility.) Data from the selected dome camera can be  
stored in the keyboard controller temporarily. If you want to save the data of all  
installed dome cameras, you need a special I/O interface and software for PC.  
• ORIGIN OFFSET  
This feature is useful to align a new dome camera exactly the same as the previously installed  
dome camera.  
Dome camera’s origin set and all data initialize option do not override offset values. Only the  
default set option in this menu will set the offset value to zero. This can be used to avoid ceiling  
obstructions.  
• DOME RESET  
This feature is used to re-calibrate the orientation of a selected dome camera. Origin offset value  
is not affected by this function. (Offset is still valid after origin set)  
• SYSTEM INFORMATION  
SYSTEM INFORMATION  
CAMERA TYPE : XXXXXXX  
H/W VERSION : V1.0  
ROM VERSION : V1.0  
PROTOCOL  
BUADRATE  
: F2E  
: 9600BPS  
EXIT(ESC TO EXIT)  
A Dome camera’s Setup menu provides essential information about the dome camera if service  
is required. When you view this screen, you can determine the camera type, ROM version.  
The information on this screen cannot be modified.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix A — Specifications  
Camera(HID2404SLExxx)  
Image Sensor  
1/4" Super HAD Color CCD (Sony)  
NTSC : 768x494 Approx. 380K pixels  
PAL : 752x582 Approx. 440K pixels  
Picture elements  
Horizontal Resolution  
470 / 460 lines(NTSC/PAL)  
18x optical zoom with auto focus  
12x digital zoom  
Lens  
F1.4 to F3.0, f=4.1mm to 73.8mm  
View angle  
Approx. 48° (WIDE end) to 2.7° (TELE end)  
1.0 Lux(F1.4,normal shutter speed)  
Minimum Illumination  
S/N ratio  
more than 50dB  
Camera(HID2404SMExxx)  
Image Sensor  
1/4" Exview HAD Color CCD (Sony)  
NTSC : 768x494 Approx. 380K pixels  
PAL : 752x582 Approx. 440K pixels  
Picture elements  
Horizontal Resolution  
470 / 460 lines(NTSC/PAL)  
18x optical zoom with auto focus  
12x digital zoom  
Lens  
F1.4 to F3.0, f=4.1mm to 73.8mm  
View angle  
Approx. 48° (WIDE end) to 2.7° (TELE end)  
0.7 Lux(F1.4,normal shutter speed)  
Minimum Illumination  
S/N ratio  
0.05 lux (F1.4,1/4S(NTSC) OR 1/3S(PAL)  
0.01 Lux (1/4s with IR Cut Filter Removed)  
more than 50dB  
Camera(HID2404SHExxx)  
Image Sensor  
1/6" Super HAD Color CCD (Sony)  
NTSC : 768x494 Approx. 680K pixels  
PAL : 752x582 Approx. 800K pixels  
Picture elements  
Horizontal Resolution  
470 / 460 lines(NTSC/PAL)  
25x optical zoom with auto focus  
12x digital zoom  
Lens  
F1.6 to F2.7, f=2.4mm to 60mm  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
View angle  
Approx. 45° (WIDE end) to 2° (TELE end)  
2.5 lux(F1.4,normal shutter speed)  
Minimum Illumination  
0.2 lux (F1.4,1/4S(NTSC) OR 1/3S(PAL)  
0.01 lux (1/4s with IR Cut Filter Removed)  
S/N ratio  
more than 49Db  
ON/OFF  
Image stabilizer  
Camera(HID2404HCExxx)  
Image Sensor  
1/4" Progressive scan CCD  
NTSC : 758x504 Approx. 380K pixels  
PAL : 758x592 Approx. 450K pixels  
Picture elements  
Horizontal Resolution  
470 / 470 lines(NTSC/PAL)  
23x optical zoom with auto focus  
10x digital zoom  
Lens  
F1.6 to F3.6, f=3.6mm to 82.8mm  
View angle  
Approx. 54° (WIDE end) to 2.5° (TELE end)  
3.0 lux(F1.4,normal shutter speed)  
Minimum Illumination  
0.2 lux (F1.4,1/4S(NTSC) OR 1/3S(PAL)  
0.02 lux (1/4s with IR Cut Filter Removed)  
S/N ratio  
WDR  
more than 50dB  
ON/OFF  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
General  
Certification  
Electrical  
Input Voltage  
CE EMC, FCC CLASS A, UL  
18 to 30 VAC; 24 VAC nominal, built-in power-line surge  
24 VAC/VDC 850mA  
Power Requirement  
Power Consumption  
Maximum 20W  
Alarm Output  
Alarm Input  
Control  
4 Normal relays 24 VDC/1A Max (selectable NC/NO)  
8 Normal dry contact (selectable NC/NO)  
RS-485/422 baud rate: 2400 ~230k bps (default:9600bps)  
0.75 second maximum preset recall time  
Access Time  
ID (Camera Address)  
Mechanical  
Dimension  
Weight  
999 (Factory mode selectable over 999 camera)  
See Figure 10  
Approx 1.2 kg  
Pan Angle  
Speed  
360° continuous rotation  
0.1° to 90°/sec. (proportional to zoom)  
360°/sec. maximum (with CTRL/PGM key pressed)  
Preset Speed : 380°/sec  
Repeatability  
Flip  
0.2°  
Rotate 180° at bottom of tilt  
8 auto scan include vector scan.  
240 positions with camera status (16-character title)  
8 tours  
Autoscan  
Preset Position  
Tour  
Pattern  
Four patterns, 240 second  
Displays camera ID and area name on screen  
On-Screen Display  
Environment  
Operating temperature  
Operating humidity  
Storage temperature  
0°C to 50°C (32°F to 122(F)  
0 to 90%RH (non-condensing)  
-20°C to 60°C (4°F to 140°F)  
Specifications are subject to change without notice.  
Figure 10– Dimension  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix B — Troubleshooting  
If problems occur, verify the installation of the camera with the instructions in this manual and  
with other operating equipment. Isolate the problem to the specific piece of equipment in the  
system and refer to the equipment manual for further information.  
Problem  
Possible Solution  
Verify that power is connected to all pieces of  
equipment in the system.  
No video.  
Verify that the power switches are in the ON position.  
Check the video connections  
(see Figure 4).  
Check that the BNC connectors are inserted properly.  
Check the voltage level of the dome camera.  
Check that 8-pin cable is connected to the Keyboard.  
8-pin cable for Keyboard is proprietary. Cable for video  
is shielded.  
Poor video quality.  
Reset the cameras using the Dome configuration  
menus.  
Dome cameras lose their positions.  
Check that the dome cameras are inserted properly in  
the base.  
Check the voltage level of the dome camera.  
Camera number does not match the  
multiplexer number.  
Check the camera ID and insert the BNC cable into  
the proper input of the multiplexer.  
Check Line Lock setting and adjust phase of L/L (see  
page 22)  
Picture is torn when switching  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix C — Glossary  
Alarm Actions  
The assigned responses for the dome camera when inputs change from normal to abnormal  
states. The dome may run a Preset, Pattern, or have no assigned action for each of the four  
dome inputs. The dome may also send alarm states to the host controller for processing. See  
also Input and Normal Input State.  
Areas  
Programmed start and end points of the dome's field of view around its pan axis.  
Each area is a part of a circular viewing area that extends around the dome. The areas can be  
different sizes. Up to 16 areas can be programmed for the dome.  
Automatic Gain Control (AGC)  
Allows for the amplification of the video signal in scenes with minimal ambient light. Many low-  
light scenes result in picture noise. As gain is increased, the picture noise is also amplified.  
When AGC is enabled, the value of the gain setting is based on feedback from the camera.  
When AGC is disabled, the camera uses the value set for the manual gain setting. The trade-off  
between picture level and noise may be adjusted when AGC is disabled.  
On-screen Menu  
The text overlay menu system used for setting dome features. The utility is accessed using a  
keystroke combination. The utility provides settings for camera functions, zoom, alarms, text  
display, and password protection.  
Flip  
Allows the dome to automatically turn 180 degrees when the camera tilts to its lower limit and  
stays in that position for a brief delay. When the dome flips (rotates), the camera starts moving  
upward as long as the tilt control is kept in the down position. Once the control is released, the  
tilt control returns to its normal operational mode. The flip feature is useful when you need to  
track someone who walks directly beneath the dome and continues on the other side.  
Home Position  
The default position to which the dome camera returns after an assigned period of inactivity  
passes. The default position may be a Preset, Tour, Pattern, or No Action.  
Input Alarm  
A connection point on the dome camera that enables the system to monitor Input Devices. There  
are four inputs available for the dome camera.  
Input Devices  
External devices that provide information about the condition of system components that  
connect to the inputs on the dome camera. Typical input devices include door contacts, motion  
detectors and smoke detectors.  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IR Mode  
A feature of the camera that permits manual or automatic switching between color and IR  
(black-and-white) operation. When IR mode is active, clearer images may be obtained under  
low-light conditions.  
Line Lock  
Allows you to phase lock the video with the AC power line. When line lock is enabled, it prevents  
vertical video rolling when switching multiple cameras to a single monitor. If text appears slightly  
tinted on color monitors, disabling the line lock may prevent this problem.  
Name Information  
Relates to the display the dome name, the area where the dome is pointing, the name of the  
preset or pattern that is running, and alarm names. The display of each type of name setting can  
be enabled or disabled. When the display of camera or area title(name) is enabled, the  
information appears on the screen continuously. Preset, tour and pattern titles(names) appear  
only while they are active.  
Normal Input State  
Describes the expected state of a device connected to one of eight dome camera’s inputs. The  
normal state may be open or closed. When a device is not in its normal input state, an alarm is  
issued.  
North Position  
User-definable setting that may correspond to magnetic north or some well-known landmark.  
Used to approximate the camera dome's pointing direction when Direction Indicators are  
enabled.  
Low Shutter  
Setting used to improve the quality of video obtained in extreme low-light situations. When the  
Low Shutter setting is enabled, low-light information is collected over multiple fields based on the  
Shutter Limit setting. As a result, video may appear blurred or choppy in extreme low-light  
situations. This setting does not effect camera operation in normal lighting situations. See also  
Automatic Gain Control (AGC).  
Pattern  
A series of pan, tilt, zoom and focus movements from a single programmable dome. Up to 8  
patterns may be programmed for the dome camera.  
Preset  
Programmed video scene, based on a specific pan, tilt, zoom, and focus settings. Up to 240  
presets may be programmed for the dome camera.  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Privacy Zones  
Masked areas of the dome camera's viewing area. These masks prevent operators of the  
surveillance system from viewing these designated zones. The Privacy Zones move in relation  
to the dome camera’s pan/tilt position. In addition, the apparent size of the Privacy Zone adjusts  
automatically as the lens zooms in or out. Up to eight Privacy Zones may be established for a  
dome camera.  
Shutter Limit  
Setting used to define the maximum exposure time for the Open Shutter setting. The values for  
the setting range from 1/2 to 1/60. The default setting is 1/4.  
Vector Scan  
Move from start point to end point including tilt and zoom simultaneously and linearly.  
WDR  
Wide Dynamic Range Technology uses two shutter speeds in alternative video fields-high and  
normal- every 60th (or 50th) of a second and combines two fields into one progressive scan  
frame. It allows every detail to be captured accurately even if one portion of an image is  
brilliantly. Whether at the high shutter speed or normal shutter speed, the progressive scan CCD  
provides a horizontal resolution of 470 lines. As a result, combined fields yield a frame of high-  
quality images.  
White balance  
Adjustments in the color hue (red and blue) gains for a camera so that true white appears white  
in the image. It is normally compensated for by the automatic gain control. In some lighting  
conditions, you may need to manually adjust the red and blue settings for optimal viewing. When  
Automatic White Balance is enabled, the camera measures the image and automatically adjusts  
the red and blue settings to balance white. When Automatic White Balance is disabled, the  
camera uses the values set for the red and blue settings to balance white.  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix D — Short Cut Key  
Short Cut Key  
PRST  
Function  
Pop up preset setup menu.  
Pop up guard Tour setup menu.  
Pop up Pattern setup menu.  
Pop up Auto Scan setup menu.  
TOUR  
PTRN  
SCAN  
NO.+ PGM +PRST Store the current view at the selected number.  
NO.+ PGM +TOUR Pop up tour setup menu at the selected number.  
NO.+ PGM +SCAN Pop up auto scan setup menu at the selected number.  
1 ~ 4 + ON  
1 ~ 4 + OFF  
10 + ON  
Turn On Relay.  
Turn Off Relay.  
Night Shot on  
10 + OFF  
11 + ON  
Night Shot off  
BLC on  
11 + OFF  
12 + ON  
BLC off  
Digital Zoom on (According to digital zoom setting)  
Digital Zoom off  
12 + OFF  
13 + ON  
Dome OSD on  
13 + OFF  
14 + ON  
Dome OSD off  
Dome Area Title Display on  
Dome Area Title Display off  
View Direction on  
View Direction off  
Shutter speed auto  
Shutter speed 1/4 (PAL 1/3)sec  
Shutter speed 1/2 sec  
Shutter speed 1 sec  
WDR on  
14 + OFF  
15 + ON  
15 + OFF  
100 + ON  
101 + ON  
102 + ON  
103 + ON  
104 + ON  
104 + OFF  
105 + ON  
105 + OFF  
150 + ON  
150 + OFF  
WDR off  
Stabilizer on  
Stabilizer off  
Image Reverse on  
Image Reverse off  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECODOME CAMERA  
040705  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sharp Cash Register TINSZ2600RCZZ User Manual
Sharp Microwave Oven R 239 User Manual
Snapper Blower 06117 User Manual
Sony Computer Monitor SDM S75FS User Manual
Sony CRT Television KP 57XBR10W User Manual
Spectra Clock Radio KT2089 User Manual
Sunrise Medical Dishwasher 374 90010 User Manual
Superior Indoor Fireplace GHC GRD 5500 User Manual
Sylvania CRT Television RSDCT3203 User Manual
Tanaka Brush Cutter TBC 220 User Manual