Southbend Electric Steamer EZ 3 User Manual

IMPORTANT FOR FUTURE REFERENCE  
Please complete this information and retain this  
manual for the life of the equipment:  
Model #: __________________________  
Serial #: __________________________  
Date Purchased: ___________________  
OPERATOR'S MANUAL  
FOR MODEL EZ-3 and EZ-5  
Simple Steam  
COUNTERTOP STEAMERS  
Model EZ-3  
Model EZ-5  
! WARNING  
Improper installation, operation, service, or maintenance can cause property damage, injury, or death.  
Read this manual thoroughly before installing and operating this equipment.  
1100 Old Honeycutt Road, Fuquay-Varina, NC 27526  
(800) 348-2558 or (919) 552-9161 FAX (800) 348-2558 or (919) 552-9798  
MANUAL 1178387 REV 2  
$18.00  
COUNTERTOP STEAMER  
MANUAL SECTION ST  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
TABLE OF CONTENTS  
Congratulations! You have purchased one of the finest pieces of heavy-duty commercial cooking equipment  
on the market.  
You will find that your new equipment, like all Southbend equipment, has been designed and manufactured  
to meet the toughest standards in the industry. Each piece of Southbend equipment is carefully engineered  
and designs are verified through laboratory tests and field installations. With proper care and field  
maintenance, you will experience years of reliable, trouble-free operation. For best results, read this  
manual carefully.  
RETAIN THIS MANUAL FOR FUTURE REFERENCE.  
Table of Contents  
Specifications..........................................................................................................................4  
Installation...............................................................................................................................5  
Operation ................................................................................................................................9  
Cooking Hints........................................................................................................................10  
Cleaning................................................................................................................................13  
Troubleshooting ....................................................................................................................15  
Parts......................................................................................................................................37  
Limited Warranty...................................................................................................................41  
Read these instructions carefully before attempting installation. Installation and initial startup should be  
performed by a qualified installer. Unless the installation instructions for this product are followed by a  
qualified service technician (a person experienced in and knowledgeable with the installation of commercial  
gas an/or electric cooking equipment) then the terms and conditions on the Manufacturer's Limited Warranty  
will be rendered void and no warranty of any kind shall apply.  
In the event you have questions concerning the installation, use, care, or service of the product, write to:  
Technical Service Department  
Southbend  
1100 Old Honeycutt Road  
Fuquay-Varina, North Carolina 27526 USA  
The serial plate is located on the right side of the unit near the back and top (see Figure 2 on page 7).  
OPERATORS MANUAL 1178387 REV 2  
PAGE 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
SPECIFICATIONS  
DIMENSIONS  
E
C
A
B
D
SIDE VIEW  
FRONT VIEW  
TOP VIEW  
= Electrical Connection Terminal Block  
Width  
A
Height  
B
Depth  
C
Electrical Connection  
Crate Size  
Crated  
Weight  
Model  
D
E
Width  
Depth  
Height  
Volume  
16.375"  
416 mm  
24.25"  
616 mm  
30.25"  
768 mm  
6"  
153 mm  
2.44"  
62 mm  
20"  
508 mm  
34"  
864 mm  
37"  
940 mm  
14.6 cu. ft.  
0.41 cu. m.  
150 lbs.  
68 kg.  
EZ-3  
EZ-5  
16.375"  
416 mm  
30.25"  
762 mm  
30.25"  
768 mm  
6"  
153 mm  
2.44"  
62 mm  
20"  
508 mm  
34"  
864 mm  
37"  
940 mm  
14.6 cu. ft.  
0.41 cu. m.  
175 lbs.  
79 kg.  
Internal Dimensions: EZ-3: 13.5" W x 22" D x 9.5" H; EZ-5: 13.5" W x 22" D x 15.5" H  
UTILITY INFORMATION  
One electric connection is required.  
IMPORTANT: UNIT MUST BE LEVEL FOR PROPER OPERATION. WARRANTY WILL BE VOIDED FOR  
IMPROPER INSTALLATION.  
All units shipped per customer order, three phase or single phase.  
Kit available for field conversion to three phase or single phase.  
Max. Amps per Line  
EZ-3  
EZ-5  
Total Connected Amps  
1 Phase  
40  
3 Phase  
24  
1 Phase  
57  
3 Phase  
33  
208 V 60 Hz  
220 V 50/60 Hz  
240 V 60 Hz  
38  
23  
54  
31  
35  
21  
49  
29  
380/220 V 50 Hz  
415/240 V 50 Hz  
480 V 60 Hz  
23  
14  
31  
19  
21  
13  
29  
17  
18  
13  
25  
15  
Circuit must be wired for maximum amps at required voltage.  
PAGE 4  
OPERATORS MANUAL 1178387 REV 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
INSTALLATION  
INSTALLATION  
! WARNING  
DO NOT CONNECT 3/4” ID GREY HOSE IN REAR OF UNIT TO ANYTHING. THESE ARE VENT  
HOSES AND MUST BE ALLOWED TO DRAIN INTO PAN. FAILURE TO COMPLY COULD CAUSE  
A DANGEROUS PRESSURE RISE INSIDE OF THE STEAMER.  
!
CAUTION  
Do not locate unit adjacent to any high heat or grease producing piece of equipment, such as a range  
top, griddle, fryer, etc., that could allow radiant heat to raise the exterior temperature of the steam  
body above 130°F (54°C). DO NOT MOUNT ABOVE OTHER COOKING EQUIPMENT.  
NOTICE  
These installation procedures must be followed by qualified personnel or warranty will be void.  
Local codes regarding installation vary greatly from one area to another. The National Fire Protection  
Association, Inc. states in its NFPA 96 latest edition that local codes are the “authority having  
jurisdiction” when it comes to installation requirements for equipment. Therefore, installations should  
comply with all local codes.  
The unit, when installed, must be electrically grounded and comply with local codes, or in the  
absence of local codes with the National Electrical Code ANSI/NFPA 70-latest edition.  
Canadian installation must comply with CSA-Standard (C22.2 No. 109-M1981 General  
Requirements-Canadian Electrical Code, Part II. 109-M1981) Commercial Cooking Appliances.  
Step 1: Unpacking  
IMMEDIATELY INSPECT FOR SHIPPING DAMAGE  
All containers should be examined for damage before and during unloading. The freight carrier has  
assumed responsibility for its safe transit and delivery. If damaged equipment is received, either  
apparent or concealed, a claim must be made with the delivering carrier.  
Apparent damage or loss must be noted on the freight bill at the time of delivery. The freight bill must  
then be signed by the carrier representative (Driver). If the bill is not signed, the carrier may refuse  
the claim. The carrier can supply the necessary forms.  
A request for inspection must be made to the carrier within 15 days if there is concealed damage or  
loss that is not apparent until after the equipment is uncrated. The carrier should arrange an  
inspection. Be certain to hold all contents plus all packing material.  
OPERATORS MANUAL 1178387 REV 2  
PAGE 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
Step 2: Install the Legs  
1. Uncrate carefully. Report any hidden damage to the freight carrier IMMEDIATELY.  
2. Do not remove any tags or labels until unit is installed and working properly.  
3. Remove placeholder bolts holding bottom cover onto unit and discard.  
4. Screw legs into the bottom of the unit until approximately 1/4" of thread is showing. The legs with rubber  
suction cups go on the back of unit.  
5. Slip drain pan guides into place between legs and bottom of steamer, as shown in Figure 1, making sure  
that pan stops are toward the rear of the unit.  
6. Tighten legs, making sure that the pan guides stay seated against the leg threads.  
7. To level the unit, adjust the base of unit’s legs.  
8. Place custom drain pan under unit.  
Figure 1  
NOTICE  
Unit must be level to assure maximum performance. Improper leveling may void warranty.  
!
CAUTION  
WATER FROM A FULL CAVITY CANNOT BE HELD IN A 12" x 20" X 2½" PAN..  
PAGE 6  
OPERATORS MANUAL 1178387 REV 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
INSTALLATION  
Step 2: Electric Connection  
A field connection Fuse Block is located at the rear of the unit, lower left side. A hole is provided for a 3/4”  
conduit fitting (solid or flex). Rear cover and fuse block cover must be removed to gain access to fuse block.  
Refer to Figure 2.  
Be sure that the input voltage matches the requirement on the serial plate. The unit is factory wired per  
customer order.  
! WARNING  
A POSITIVE GROUND CONNECTION IS ESSENTIAL. DO NOT ALLOW ANY TAMPERING OR  
ADJUSTMENT OF ANY CONTROL OR WIRING. THE UNIT IS FACTORY SET. ADJUSTING ANY  
INTERNAL COMPONENT OTHER THAN THE MAIN FUSE BLOCK CAN VOID THE WARRANTY.  
THIS UNIT REQUIRES A KIT TO BE FIELD CONVERTED FROM THREE-PHASE TO SINGLE-  
PHASE OR VICE-VERSA. CONSULT FACTORY FOR PHASE CHANGES.  
All 208-220-240 and 480 volt units will have three fuse block sections, “L1-L2-L3”, for use with either 3-wire  
3-phase or 2-wire, single-phase, 50 or 60 Hz. All 380V and 415V units will have four fuse block sections, “L1-  
L2-L3-N,” for use with European style 4-wire 3-phase with neutral.  
Figure 2  
Serial  
Plate  
Fuse Block  
3/4" Conduit  
Fitting Hole  
Fuse Block Cover  
(shown removed)  
Rear Cover  
OPERATORS MANUAL 1178387 REV 2  
PAGE 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
Step 3: Optional Floor Drain  
The drain valve is 1/2’’ NPT. Position the unit near, but not on top of, an open floor drain. Allow at least a 1"  
air gap.  
DO NOT directly plumb to the unit unless you also install an “open funnel” downstream of this connection in  
the drain system. The “open funnel” is intended to eliminate any water from entering the steamer because of  
a blocked drain. Any connection that allows the build-up of back pressure in the unit (such as a reduction in  
pipe size to a line smaller than 1/2’’or a 90 degree angle in the line prior to the “open funnel” drain discharge  
point) may cause personal or property damage and will therefore void the warranty. (See Figure 3)  
Figure 3  
PERFORMANCE CHECK  
The following items should be checked within the first 30 days of operation by a qualified service technician.  
1. Check doors for proper alignment.  
2. Ensure proper opening and closing of doors.  
3. Open door and remove cavity bottom cover, if present.  
4. Ensure that the light comes on when lever is set to the ‘’ON” position.  
5. An audible ‘’click” should be heard when the door switch actuator rod is depressed and held. This  
indicates proper functioning of the contactor as it closes. You should hear a second audible ‘’click” (in  
less than 75 seconds) as the contactor opens. Release rod.  
6. Pour approximately 2 gallons of water into trough, ensuring that the cavity bottom is covered.  
7. Depress and hold the door switch for 2 minutes. The contactor should close when the switch is first  
depressed and stay closed during this period.  
8. Close the door and wait approximately 12 minutes until the contactor closes, indicating the unit has  
reached operating temperature.  
PAGE 8  
OPERATORS MANUAL 1178387 REV 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
OPERATION  
OPERATION  
STARTUP  
1. If the cavity bottom cover is present, open door and remove.  
2. Turn lever to ‘’ON’’ position with door open.  
3. Important: Pour water into trough above the door until water is observed passing through the fill / drain  
opening at left rear corner of cavity bottom.  
4. Add additional water through trough or through door up to ‘’-WATER LEVEL-’’ mark.  
NOTICE: WATER SPECIFICATION  
To meet warranty requirements, supply water must meet the following specification:  
Total Dissolved Solids (TDS)........... 60 PPM  
Hardness.......................................... 2 Grains or 35 PPM  
pH Factor ......................................... 7.0 to 7.5  
5. Replace cavity bottom cover (if present).  
6. Unit will be ready for cooking in approximately 12 minutes.  
OPERATION  
1. Suggested cooking times for various foods are shown in the table in the following section.  
2. Pan specifications are shown on specifications page (page 4).  
3. The door may be opened or closed at any time.  
4. Unit will automatically idle at operating temperature when and if the door is closed and there is no food in  
the cavity.  
5. Timer can be used as desired. However, it has no effect on unit operation.  
6. Add proper amount of water through the trough (above the door) or directly through the door when water  
level is low.  
7. If unit runs out of water the ‘’CHECK WATER LEVEL’’ light will illuminate. Follow step # 6, above.  
SHUTDOWN  
1. The custom drain pan or a 12”x 20”x 4” non-perforated stainless steel pan should be located under the  
unit at all times.  
2. Turn lever to the “OFF” position.  
3. Empty drain pan after allowing water to cool.  
4. Remove pan guides and cavity bottom cover (if present).  
5. Wipe out steamer (with Lime-A-Way or equivalent deliming solution as necessary), RINSE  
THOROUGHLY WITH CLEAN WATER.  
6. Ensure drain opening is clear.  
7. Replace pan guides and cavity bottom cover (if present).  
8. Leave the door open at night after cleaning.  
9. DO NOT USE high-chlorine or bleach solution for cleaning the door gasket.  
10. DO NOT USE steel wool or other metallic pads in the steamer.  
OPERATORS MANUAL 1178387 REV 2  
PAGE 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
COOKING HINTS  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
COOKING HINTS  
COOKING TIPS  
Schedule cooking of fresh vegetables so that they will be served soon after they are cooked. If it is  
necessary to prepare them in advance, they can be plunged into cold water, drained thoroughly and held  
under refrigeration until needed for service.  
Five pounds of cold cooked vegetables can be reheated in the steamer in 5 to 10 minutes, depending upon  
the variety.  
SUGGESTED COOKING TIMES  
Timer settings are for general guidance only. Differences in food quality, size, shape, freshness, load size,  
and desired degree of doneness must be taken into consideration and adjustments made in time, if  
necessary.  
Cooking Time  
Product  
Weight  
Portions  
(minutes)  
Pan Used  
Asparagus  
Fresh  
3½ lbs.  
5 lbs.  
14 (4 oz.)  
20 (4 oz.)  
8-10  
9
Full/Perforated  
Full/Perforated  
Frozen Spears (Thawed)  
Beans  
Green - Frozen, Cut  
Green - Fresh  
Wax - Frozen  
Lima - Frozen  
5 lbs.  
5 lbs.  
5 lbs.  
5 lbs.  
20 (4 oz.)  
20 (4 oz.)  
20 (4 oz.)  
20 (4 oz.)  
12  
15-17  
13  
Full/Perforated  
Full/Perforated  
Full/Perforated  
Full/Perforated  
10  
Broccoli  
Spears -Fresh  
Spears - Frozen (Thawed)  
4 lbs.  
5 lbs.  
16 (4 oz.)  
20 (4 oz.)  
10-12  
8
Full/Perforated  
Full/Perforated  
Brussel Sprouts  
Fresh  
Fresh  
5 lbs.  
5 lbs.  
20 (4 oz.)  
20 (4 oz.)  
15-17  
13  
Full/Perforated  
Full/Perforated  
Carrots  
Frozen - Whole Baby  
Fresh - ¼-inch Bias Cut  
5 lbs.  
5 lbs.  
20 (4 oz.)  
20 (4 oz.)  
12  
12  
Full/Perforated  
Full/Perforated  
Cabbage  
Green, Cut Into Wedges  
Red, Cut Into Wedges  
24  
16  
15  
18-20  
Full/Perforated  
Full/Perforated  
Cauliflower  
Fresh, Whole  
Fresh, Whole  
Frozen, Flowerettes  
2 lbs.  
2 lbs. 12 oz.  
5 lbs.  
8 (4 oz.)  
11 (4 oz.)  
20 (4 oz.)  
9-10  
15  
10-12  
Full/Perforated  
Full/Perforated  
Full/Perforated  
Corn  
Fresh, Cob, 4-5 Inch Ears  
Frozen - Whole Kernel  
Frozen - Cob, 6 Inch Ears  
5½ lbs.  
5 lbs.  
9 lbs.  
15  
20 (4 oz.)  
14  
13-15  
8
12-14  
Full/Perforated  
Full/Perforated  
Full/Perforated  
Table continues on next page.  
PAGE 10  
OPERATORS MANUAL 1178387 REV 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
COOKING HINTS  
Table continuing from previous page.  
Cooking Time  
Product  
Weight  
5 lbs.  
Portions  
20 (4 oz.)  
20 (4 oz.)  
(minutes)  
Pan Used  
Mixed Vegetables  
Frozen  
12  
8
Full/Perforated  
Full/Perforated  
Peas  
Frozen  
5 lbs.  
Potatoes  
Red Bliss - Whole  
Russetts - Whole  
Russetts - Peeled  
Russetts 1-Inch Cubes  
7 lbs.  
8 lbs.  
5 lbs.  
5 lbs.  
28  
20  
12  
35  
25-35  
20  
Full/Perforated  
Full/Perforated  
Full/Perforated  
Full/Perforated  
20 (4 oz.)  
17  
Spinach  
Fresh, Leaf  
Frozen, Chopped  
2½ lbs.  
6 lbs.  
10 (4 oz.)  
24 (4 oz.)  
5
35  
Full/Perforated  
Full/Perforated  
Zucchini  
Fresh - Slices ¼-inch Thick  
5 lbs.  
20 (4 oz.)  
6-8  
Full/Perforated  
Broccoli  
Spears -Fresh  
Spears - Frozen (Thawed)  
4 lbs.  
5 lbs.  
16 (4 oz.)  
20 (4 oz.)  
10-12  
8
Full/Perforated  
Full/Perforated  
Eggs  
Large - Hard Cooked  
12 lbs.  
12  
15-16  
½ Perforated  
Meats  
Corned Beef  
Hot Dogs, Thawed  
Hot Dogs, Frozen  
6¾ lbs.  
5 lbs.  
5 lbs.  
18 (6 oz.)  
40 (2 oz.)  
40 (2 oz.)  
2 hours  
5
10  
Full  
Full/Perforated  
Full/Perforated  
Fowl  
Boneless Chicken Breast  
4½ lbs.  
12 (6 oz.)  
15  
Full/Perforated  
Tamales, Frozen  
Tortilla, Frozen 8-Inch  
3 lbs.  
4 Tortillas  
12 (4 oz.)  
4
20  
Full/Perforated  
Half/Perforated  
45 Seconds  
Beef Ravioli, Frozen  
Elbow Macaroni  
Spaghetti  
48 Ravioli  
(1 lb. 8 oz.)  
8
5-6  
Full/Perforated  
2 lbs.  
Uncooked  
32 (2 oz.)  
32 (2 oz.)  
32 (2 oz.)  
7
In Perforated Pan  
Nested in Solid Pan  
2 lbs.  
Uncooked  
14  
10  
25  
In 4-Inch  
Full/Perforated  
Egg Noodles  
2 lbs.  
Uncooked  
Full/Perforated  
Converted Rice  
2 lbs.  
Full/Perforated  
2½ Qts. Water  
+ Oil & Salt  
Navy Beans  
2 lbs.  
Full/Perforated  
Place beans in pan and cover with 3-quarts hot tap  
water. Steam for 2 minutes; remove from steamer  
and cover for 1 hour. Remove cover and place back  
in steamer for 40 minutes.  
Table continues on next page.  
OPERATORS MANUAL 1178387 REV 2  
PAGE 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
COOKING HINTS  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
Table continuing from previous page.  
Cooking Time  
Product  
Weight  
Portions  
(minutes)  
Pan Used  
Black Eyed Peas  
2 lbs.  
Full/Perforated  
Place beans in pan and cover with 3-quarts hot tap  
water. Steam for 2 minutes; remove from steamer  
and cover for 1 hour. Remove cover and place back  
in steamer for 35 minutes.  
Oysters  
5 lbs.  
16 Count  
12  
Perforated Pan  
Nested in Full Pan  
2½-Inch Deep  
Shrimp, Fresh, Medium, Heads Removed  
Shrimp, Frozen, Large, Peeled & Deveined  
Lobster  
5 lbs.  
5 lbs.  
6-7  
8
Full/Perforated  
Full/Perforated  
Full/Perforated  
Full/Perforated  
Full/Perforated  
1¾ lbs.  
1 lb.  
8
Alaskan King Crab Legs  
Cherrystone Clams  
4-5  
7
5 lbs.  
12  
Fish Fillets  
7½ lbs.  
12 (10 oz.)  
18  
Full/Perforated  
Nested in Full  
Hotel Pan  
For eggs cooked in the shell, adding salt to the cooking water increases cooking efficiency and decreases cooking  
time. If the egg cracks, the white is cooked at the crack and is sealed right away.  
To avoid green yolk (which is a deposit of iron sulfide) chill the eggs immediately after removing from the steamer by  
plunging them into a cold water bath (preferably containing ice).  
A quick and easy way to cook eggs for a salad mixture is to crack them directly into a solid steam table pan which has  
been lightly coated with salad oil. Do not mix. Steam until they are hard cooked. Remove and chop as you would for  
egg salad. The job of peeling is eliminated.  
Transfer steamed hot chicken to deep pan, cover with Cacciatore Sauce and finish in oven. Bake 20 to 30 minutes.  
May be held on steam table.  
Chicken, sausage, and/or fish may be browned in Infra-Red or Radiant Broiler after steaming by brushing with melted  
margarine mixed with salad oil to give a golden brown color.  
Save juices from steamed chicken or turkey to make soups, sauces, or casserole dishes.  
Chicken may be steamed in advance and refrigerated for next day’s use. Be sure to bring product back to 180°F  
before serving.  
Save the juice from the corned beef. After the cabbage has been steamed, place it in a solid pan and add the juice for  
flavoring and holding on a steam table.  
Steaming brisket is a definite time saver. Boiling in water takes 40 to 50 minutes per pound. Using the Simple Steam  
can save 50% in cooking time.  
Cabbage, when steamed, retains its color and wedge identity. It will not break apart as it does when boiled in an open  
pot.  
When removing items prepared in a perforated pan, place a solid pan underneath the perforated pan with the cooked  
food in order to prevent dripping on the floor.  
The Simple Steam is designed to accept standard 12 x 20 pans. Fractional size pans and dishes can be used as well  
with the optional perforated shelf.  
For stirring, the pan does not have to be removed from the steamer. Pull pan 1/3 way out of the cavity and the entire  
surface is accessible.  
The door may be opened at any time during operation to remove or add food.  
PAGE 12  
OPERATORS MANUAL 1178387 REV 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
CLEANING  
CLEANING  
Southbend equipment is constructed with the best quality materials and is designed to provide durable  
service when properly maintained. To expect the best performance, your equipment must be maintained in  
good condition and cleaned daily. Naturally, the frequency and extent of cleaning depends on the amount  
and degree of usage.  
Following daily and more extensive periodic maintenance procedures will increase the life of your equipment.  
Climatic conditions (i.e., salt air, seasonings, and water quality) may result in the need for more thorough and  
more frequent cleaning in order to keep equipment performing at optimal levels.  
! WARNING: BURN HAZARD  
For proper and safe operation, this steamer must be cleaned daily as described in this manual.  
Failure to do so could result in serious injury or damage.  
Drains must be kept clean and clear of debris.  
! WARNING: SHOCK HAZARD  
DO NOT GET WATER IN THE CONTROLS.  
This could result in expensive repairs and/or electrical shock.  
De-energize all power to equipment before cleaning the equipment.  
DAILY CLEANING  
Remove pan guides and cavity bottom cover (if present).  
Wipe out steamer (with Lime-A-Way or equivalent deliming solution as necessary) and rinse thoroughly  
with clean water.  
Make sure drain opening is clear.  
Replace pan guides and cavity bottom cover (if present).  
Leave the door open at night after cleaning.  
Do not clean the door gasket with a high-chlorine solution or bleach.  
Do not use steel wool or other metallic pads in the steamer.  
PERIODIC CLEANING  
If lime or mineral deposit starts to build up in the interior, clean the unit by using Southbend “descaler” or  
other non-caustic deliming solution. Follow manufacturer’s recommended procedures. Thoroughly rinse  
out unit with clean water.  
To remove normal dirt, grease, or product residue from stainless steel, use ordinary soap and water  
applied with a sponge or cloth. Dry thoroughly with a clean cloth. Never use vinegar or any corrosive  
cleaner.  
Occasionally drain rear water box. To remove grease and food splatter or condensed vapors that have  
baked on the equipment, apply cleanser to a damp cloth or sponge and rub cleanser on the metal in the  
direction of the polishing lines on the metal. Rubbing cleanser as gently as possible in the direction of the  
polished lines will not mar the finish of the stainless steel. NEVER RUB WITH A CIRCULAR MOTION.  
Soil and burnt deposits which do not respond to the above procedure can usually be removed by rubbing  
OPERATORS MANUAL 1178387 REV 2  
PAGE 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLEANING  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
the surface with SCOTCH-BRITE scouring pads. DO NOT USE ORDINARY STEEL WOOL, as any  
particles left on the surface will rust and further spoil the appearance of the finish. NEVER USE A WIRE  
RUSH, STEEL SCOURING PAD, SCRAPER, FILE OR OTHER STEEL TOOLS. Surfaces which are  
marred collect dirt more rapidly and become more difficult to clean. Marring also increases the possibility  
of corrosive attack. Refinishing may then be required.  
SEMIANNUAL CLEANING  
At least twice a year, have your Southbend Authorized Service Agency or another qualified service  
technician clean and adjust the unit for maximum performance. Semiannual cleaning should include the  
following:  
1. Remove rear cover.  
2. Place a (1) gallon container under the water seal box drain valve (see Figure 12 on page 29).  
3. Open drain valve, and close valve when box is finished draining.  
4. Add one gallon of deliming solution to the trough above the door.  
5. Add two gallons of deliming solution through the door into the cavity  
6. Turn unit on, let run for 30 minutes.  
7. Turn unit off and drain all solution from the cavity.  
8. Drain solution from water seal box as in steps 2 and 3.  
9. Fill unit with clean water THROUGH THE TROUGH and drain. Repeat 2 times.  
Consult the Southbend Authorized Parts/Service Distributor list for the Authorized Service Representative in  
your area or contact Southbend at 1-800-348-2558 for this information.  
PAGE 14  
OPERATORS MANUAL 1178387 REV 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
TROUBLESHOOTING  
TROUBLESHOOTING  
This section contains a troubleshooting key and referenced flowcharts to assist a qualified service technician  
in the servicing of a EZ-3 or EZ-5 Countertop Steamer.  
TROUBLESHOOTING KEY  
Find the symptom below that corresponds to the malfunction, then turn to the corresponding figure and page.  
Follow the flowchart on that page until the problem is solved.  
Symptom  
Page  
Unit Not Heating Up, "ON" Light Not Lit  
16  
17  
18  
19  
20  
Unit Not Heating Up Properly or Not Cooking As Fast, "ON" Light Lit  
Unit Using Excessive Amount of Water and/or Excessive Steam Coming from Vent Tube  
"Check Water Level" Light Does Not Come On When Unit Runs Out of Water  
Buzzer Does Not Come On  
TROUBLESHOOTING FIGURES AND PROCEDURES  
Figure and/or Procedure  
Page  
Voltage Check at Control Panel Fuse Block  
Heating Element Resistance Check (at contactor)  
Main Fuse Replacement  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
Power Switch Continuity Check  
Contactor Coil and MOV Check  
Idle Element Resistance Check  
Timer and Buzzer Check  
Door Switch Continuity Check  
Float Switch Continuity Check  
High Limit Continuity Check  
Time Delay Relay Check (EZ-3 only)  
Controller Check (EZ-5 only)  
Electric Schematic for 208-240 Volt 60 Hz or 220 Volt 50 Hz Model EZ-3  
Electric Schematic for 480 Volt Model EZ-3  
Electric Schematic for 208-240 Volt 60 Hz or 220 Volt 50 Hz Model EZ-5  
Electric Schematic for 480 Volt Model EZ-5  
OPERATORS MANUAL 1178387 REV 2  
PAGE 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
Unit Not Heating Up, "ON" Light Not Lit  
Unit not heating up, "ON" light not lit.  
Check that circuit breaker is ON and that proper voltage is  
available at main fuse block.  
DISCONNECT POWER AT CIRCUIT BREAKER.  
Remove control panel without disconnecting plug.  
Turn lever to "ON" position.  
Reconnect power.  
Check voltage between A and B on control panel fuse  
(see Figure 4 on page 21).  
Does voltage  
meet specifications?  
No  
Yes  
DISCONNECT POWER AT CIRCUIT BREAKER.  
Check voltage on side C and D on control panel  
fuse block (see Fig. 4 on page 21).  
Check resistance between contactor terminals  
(see Figure 5 on page 22).  
Does voltage  
meet specifications?  
Yes  
No  
Is measured resistance  
No  
consistent with the table in  
Figure 5 (see page 22)?  
Yes  
Check voltage across  
terminals 1 and 6 of  
terminal block  
Check for short circuit in  
power switch (see Fig. 7  
on page 24), contactor coil  
and MOV (see Fig. 8 on  
page 25), idle element  
(see Fig. 9 on page 26),  
and buzzer (see Fig. 10  
on page 27). Replace as  
necessary.  
(see Fig. 4 on page 21).  
Replace elements and  
main fuses  
(see Fig. 6 on page 23).  
Check main fuses and  
replace as needed  
(see Fig. 6 on page 23).  
Replace control panel  
fuses.  
Does voltage  
meet specifications?  
No  
Yes  
Replace "ON" light;  
continue on next page.  
Test power switch or  
adjust so that it is  
actuated properly by cam  
on valve shaft. Replace  
switch as necessary  
(see Fig. 7 on page 24).  
PAGE 16  
OPERATORS MANUAL 1178387 REV 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
TROUBLESHOOTING  
Unit Not Heating Up Properly or Not Cooking As Fast, "ON" Light Lit  
Unit not heating up properly, or not  
cooking as fast, "ON" light lit.  
Check all three main fuses, replace as necessary.  
Is "CHECK WATER LEVEL"  
No  
Yes  
light on with door closed?  
No  
Does unit have water?  
Yes  
Drain unit. Turn unit on with door open.  
Add two gallons of water THROUGH  
TROUGH. Close door, wait 10 minutes.  
Add water according to  
start up instructions on  
door. Wait 5 minutes,  
light should go off.  
No  
Does unit heat up?  
Yes  
Check and replace time  
delay relay as necessary  
(EZ-3 only, see Fig. 14  
on page 31).  
Open door, depress  
and hold switch  
Is bottom  
of unit covered with  
deposits?  
No  
Yes  
Remind operator of  
proper filling procedure.  
DISCONNECT POWER  
AT CIRCUIT BREAKER  
Clean unit  
(see page 13)  
Check high limits and  
replace as necessary  
(see Fig. 13 on page 30).  
Does constactor  
"click" on and stay on for at  
least 2 minutes?  
No  
Yes  
Reconnect door switch  
DISCONNECT POWER  
AT CIRCUIT BREAKER  
DISCONNECT POWER  
AT CIRCUIT BREAKER  
lead wires.  
Remove rear cover.  
Remove control panel.  
Remove control panel.  
Check float switch for  
continuity and clean  
openings in float tube  
(see Fig. 12 on page 29).  
Check resistance between  
contactor terminals and  
replace any bad elements  
(see Fig. 5 on page 22).  
Remove door switch lead  
wires from terminal block  
positions 2 and 3.  
Depress door switch and  
check door switch lead  
wires for continuity  
Float  
switch and float tube  
OK?  
No  
Yes  
(see Fig. 11 on page 28).  
Replace float switch  
and clean tube.  
Check and replace contactor  
(see Fig. 8 on page 25) and  
controller (EZ-5 only, see  
Fig. 15 on page 32).  
No  
Continuity?  
Yes  
Replace door switch.  
OPERATORS MANUAL 1178387 REV 2  
PAGE 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
Unit Using Excessive Amount of Water and/or Excessive Steam Coming from Vent Tube  
Unit using excessive amount of water  
and/or excessive steam coming from  
vent tube behind the unit.  
DISCONNECT POWER  
AT CIRCUIT BREAKER  
Remove control panel,  
but leave plug connected.  
Disconnect wire C23 from terminal block position 3  
(EZ-3) or wire C98 from controller (EZ-5), reconnect  
power, turn unit on, wait 12 minutes.  
Yes  
No  
Excessive steam?  
DISCONNECT POWER AT  
CIRCUIT BREAKER  
DISCONNECT POWER AT  
CIRCUIT BREAKER  
Check float switch and float tube.  
Replace float switch and clean  
float tube as necessary  
Check time delay relay (EZ-3  
only, see Figure 14 on page 31)  
or controller (EZ-5 only, see  
Figure 15 on page 32). Replace  
if necessary  
(see Figure 12 on page 29).  
Reconnect power.  
Wait 12 minutes.  
Yes  
No  
Excessive steam?  
Check contactor and  
replace as necessary  
Reinstall control panel,  
reconnect power.  
(see Figure 8 on page 25).  
PAGE 18  
OPERATORS MANUAL 1178387 REV 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
TROUBLESHOOTING  
"Check Water Level" Light Does Not Come On When Unit Runs Out of Water  
"CHECK WATER LEVEL" light does not  
come on when unit runs out of water.  
Remove wire C17 (EZ-3) or C53 (EZ-5)  
from "CHECKWATER LEVEL" light and  
check resistance across light terminals.  
Is resistance over  
No  
Yes  
100 Kohm?  
Check High Limits  
(see Figure 13 on  
Page 30) and  
Replace light  
replace as needed.  
OPERATORS MANUAL 1178387 REV 2  
PAGE 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
Buzzer Does Not Come On  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
Buzzer does not come on.  
DISCONNECT POWER  
AT CIRCUIT BREAKER  
Remove control panel.  
Set timer for five minutes.  
Does timer  
No  
Yes  
time down?  
Remove buzzer  
lead wires  
from timer.  
Replace  
timer.  
Check timer  
(see Figure 10  
on page 27).  
Yes  
No  
Continuity?  
Replace  
buzzer  
(see Figure 10).  
Replace  
timer.  
PAGE 20  
OPERATORS MANUAL 1178387 REV 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
TROUBLESHOOTING  
Figure 4  
Voltage Check at Control Panel Fuse Block  
Power Switch  
"ON" Light  
"CHECK WATER  
LEVEL" Light  
C
A
D
B
Control  
Panel  
Fuse  
Block  
Terminal Block  
Door Switch  
1. Disconnect power at circuit breaker.  
2. Remove control panel without disconnecting plug.  
3. Turn lever to “on” position.  
4. Reconnect power.  
5. Place leads as shown.  
6. Check voltage.  
OPERATORS MANUAL 1178387 REV 2  
PAGE 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
Figure 5  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
Heating Element Resistance Check (at contactor)  
C
B
A
Contactor  
(top view)  
1. Disconnect power at circuit breaker.  
2. Remove control panel.  
3. Place test leads between terminals A and C on left side of contactor.  
4. Check the resistance and compare to the allowable range in the following table:  
Model EZ-3  
Model EZ-5  
Voltage  
Allowable Resistance (Ohms)  
Allowable Resistance (Ohms)  
208  
220  
240  
380  
415  
480  
8 to 16  
9 to 18  
6 to 12  
7 to 13  
11 to 21  
28 to 53  
34 to 63  
45 to 84  
8 to 15  
21 to 39  
24 to 46  
33 to 61  
5. Check resistance between terminals A and B and between terminals B and C similarly.  
PAGE 22  
OPERATORS MANUAL 1178387 REV 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
TROUBLESHOOTING  
Figure 6  
Main Fuse Replacement  
Fuse Block  
Fuse Block Cover  
(shown removed)  
Rear Cover  
1. Disconnect power at circuit breaker.  
2. Remove rear cover from unit.  
3. Remove fuse block cover.  
4. Check fuses for continuity.  
5. Replace as necessary.  
OPERATORS MANUAL 1178387 REV 2  
PAGE 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
Figure 7  
Power Switch Continuity Check  
Power Switch  
"C" Lead  
"NO" Lead  
Fuse Block  
1. Disconnect power at circuit breaker.  
2. Remove control panel.  
3. Turn Lever to ‘’ON’’ from ‘’OFF’’ and to ‘’OFF’’ from ‘’ON’’ ensuring that the power switch is  
properly actuated.  
4. Remove power switch lead wires from fuse block (note wire locations).  
5. Place test leads on ‘’C’’ and ‘’NO’’ lead wires as shown.  
6. Check for continuity with lever in ‘’OFF’’ position (there should be no continuity).  
7. Check for continuity with lever in ‘’ON’’ position (there should be continuity).  
8. Repeat steps 5 - 7 with test leads between other pair of ‘’C’’ and ‘’NO’’ lead wires.  
9. Place test lead on “NO” lead wire and other test lead on other “NO” lead wire.  
10. Check for continuity with lever in “ON” position (there should be no continuity).  
11. Reconnect wires or replace switch as necessary.  
PAGE 24  
OPERATORS MANUAL 1178387 REV 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
TROUBLESHOOTING  
Figure 8  
Contactor Coil and MOV Check  
Actuator  
C
B
A
F
E
D
MOV  
TOP VIEW  
LEFT SIDE VIEW  
1. Disconnect power at circuit breaker.  
2. Remove control panel and disconnect nine-pin plug PL1.  
3. Depress actuator on top of contactor. Actuator should travel freely and spring back when released.  
4. Check for continuity between contacts A and D as shown in top view. There should be no  
continuity.  
5. Repeat Step 4 for contacts B and E and for contacts C and F.  
6. Place test leads on contactor coil terminal as shown in left side view.  
7. Check resistance.  
8. If resistance is not approximately 390 (+/- 40) ohms, remove MOV and recheck coil resistance. If  
resistance is now approximately 390 (+/-40) ohms, replace MOV, otherwise replace contactor.  
9. Reconnect all wires.  
OPERATORS MANUAL 1178387 REV 2  
PAGE 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
Figure 9  
Idle Element Resistance Check  
Model EZ-3  
Model EZ-5  
High Limit  
Idle Element Plug  
1. Disconnect power at circuit breaker.  
2. Remove control panel.  
3. Disconnect idle element plug (PL3).  
4. Place test leads as shown above.  
5. Check to see if resistance is within +/- 10% of values in the following table:  
Model EZ-3  
Model EZ-5  
Voltage  
Resistance (Ohms)  
Resistance (Ohms)  
208  
220  
240  
380  
415  
480  
115  
129  
154  
385  
459  
614  
87  
97  
115  
289  
344  
461  
6. Remove one test lead, place on ground, check for short circuit.  
PAGE 26  
OPERATORS MANUAL 1178387 REV 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
TROUBLESHOOTING  
Figure 10  
Timer and Buzzer Check  
Timer  
Buzzer  
1. Disconnect power at circuit breaker.  
2. Remove control panel.  
3. Set timer for one minute and allow to time out. If timer does not run, then replace.  
4. Remove buzzer lead wires from timer and terminal block position 6, as shown.  
5. Place test leads between positions 1 and 3 on the timer.  
6. Check for continuity. If no continuity, replace timer.  
7. Place test leads in terminals of buzzer lead wires.  
8. Check physical condition of buzzer.  
9. Check that resistance is approximately 3.4Kohms. Otherwise, replace buzzer.  
OPERATORS MANUAL 1178387 REV 2  
PAGE 27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
Figure 11  
Door Switch Continuity Check  
Model EZ-5  
Model EZ-3  
Terminal Block  
Door Switch  
1. Disconnect power at circuit breaker.  
2. Remove control panel.  
3. Depress and release door switch actuator rod to make sure door switch is properly actuated.  
4. EZ-3: Remove door switch lead wires from terminal block positions 2 and 3, or  
EZ-5: Remove door switch lead wires from terminal block position 1 and terminal 2 of the controller.  
5. Place test lead as shown inside the terminal connectors of the lead wires.  
6. Check for continuity - (there should be NO continuity).  
7. Depress door switch actuator rod and check for continuity - (there should be continuity).  
PAGE 28  
OPERATORS MANUAL 1178387 REV 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
TROUBLESHOOTING  
Figure 12  
Float Switch Continuity Check  
Coupling  
Water Seal Box  
Float Switch  
Drain Valve  
Rear View of Unit with Back Cover Removed  
1. Disconnect power at circuit breaker.  
2. Remove rear cover from unit.  
3. Disconnect 2 pin float switch plug from mating plug on back of unit (PL2).  
4. Drain water seal box by opening 3/8’’ drain valve on box.  
5. Remove float switch from box by removing float switch fitting from coupling on box.  
6. Make sure float travels freely along stem.  
7. Place test leads in float switch connector as shown.  
8. Hold float switch in same orientation as when installed.  
9. Check continuity. There should not be continuity.  
10. Flip float switch over.  
11. Check for continuity. There should be continuity. Replace as necessary.  
12. Check 0.060 passages in float tube. Clean if necessary.  
OPERATORS MANUAL 1178387 REV 2  
PAGE 29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
Figure 13  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
High Limit Continuity Check  
Model EZ-5  
Model EZ-3  
Terminal Block  
C58  
C59  
C16  
C19  
1. Turn unit off.  
2. Wait for cavity bottom to cool to touch.  
3. Disconnect power at circuit breaker.  
4. Remove control panel without disconnecting plug.  
5. EZ-3: Remove wires C16 and C19 from terminal block positions 1and 2, as shown; or  
EZ-5: Remove wires C58 and C59 from terminal block positions 5 and 6, as shown.  
6. EZ-3: Place test leads as shown inside the terminal connectors of wires C16 and C19, or  
EZ-5: Place test leads as shown inside the terminal connectors of wires C58 and C59.  
7. Check for continuity.  
8. If no continuity, disconnect each high limit switch individually and check for continuity. Replace  
switches that do not have continuity. (See Figure 9 for typical high limit switch location).  
9. EZ-3: Reconnect wires C16 and C19; or  
EZ-5: Reconnect wires C58 and C59.  
10. Reconnect power at circuit breaker.  
11. Dry cavity bottom with cloth.  
12. Turn unit on with door closed.  
13. Wait 6 minutes.  
14. Disconnect power at circuit breaker.  
15. EZ-3: Remove wires C16 and C19; or  
EZ-5: Remove wires C58 and C59.  
16. Remove wires from each high limit switch individually and check for continuity. Replace switches  
that have continuity.  
PAGE 30  
OPERATORS MANUAL 1178387 REV 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
TROUBLESHOOTING  
Figure 14  
Time Delay Relay Check (EZ-3 only)  
1. Disconnect power at circuit breaker.  
2. Remove control panel, but leave plugged in.  
3. Disconnect wire C23 from terminal block position 3.  
4. Reconnect power.  
5. Depress and hold door switch. Contactor should actuate and then deactuate in approximately 60  
seconds.  
6. If contactor fails to actuate or actuates but fails to deactuate, check potentiometer on top of time  
delay relay. Make sure potentiometer is seated properly on time delay relay terminal and make sure  
it is set to 60.  
7. Depress door switch again. If contactor still fails to actuate and deactuate properly, replace time  
delay relay.  
OPERATORS MANUAL 1178387 REV 2  
PAGE 31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
Figure 15  
Controller Check (EZ-5 only)  
C98  
1. Disconnect power at circuit breaker.  
2. Remove control panel, but leave plugged in.  
3. Disconnect wire C98 from controller.  
4. Reconnect power.  
5. Use a spacer to hold door switch in closed position. Contactor should actuate and then deactuate  
in less than 60 seconds.  
6. If contactor fails to actuate (or actuates but fails to deactuate), replace controller.  
7. With spacer still in place and door open, momentarily reconnect wire C98 and then disconnect.  
8. Controller should actuate, then deactuate 10 seconds after C98 is disconnected.  
9. If contactor fails to actuate (or actuates but fails to deactuate), replace controller.  
PAGE 32  
OPERATORS MANUAL 1178387 REV 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
TROUBLESHOOTING  
Figure 16  
Electric Schematic for 208-240 Volt 60 Hz or 220 Volt 50 Hz Model EZ-3  
OPERATORS MANUAL 1178387 REV 2  
PAGE 33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
Figure 17  
Electric Schematic for 480 Volt Model EZ-3  
PAGE 34  
OPERATORS MANUAL 1178387 REV 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
TROUBLESHOOTING  
Figure 18  
Electric Schematic for 208-240 Volt 60 Hz or 220 Volt 50 Hz Model EZ-5  
OPERATORS MANUAL 1178387 REV 2  
PAGE 35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
Figure 19  
Electric Schematic for 480 Volt Model EZ-5  
PAGE 36  
OPERATORS MANUAL 1178387 REV 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
PARTS  
PARTS  
NOTICE  
INSTALLATION OF OTHER THAN GENUINE SOUTHBEND PARTS WILL VOID THE WARRANTY  
ON THIS EQUIPMENT.  
The serial plate with voltage, model, and serial information is located on the right side of the steamer cavity  
on the upper rear corner. On single units a second tag is located on the face of the door which will show  
only model and serial number. On tandem units, a second tag is on the right side of the right unit and the left  
side of the left unit.  
Replacement parts may be ordered either through a Southbend Authorized Parts Distributor or a Southbend  
Authorized Service Agency.  
When ordering parts, please supply the Model Number, Serial Number, Part Number, Description, Finish,  
and Electrical Characteristics as applicable.  
For parts not listed, consult a Southbend Authorized Parts Distributor or Southbend Authorized Service  
Agency. Consult the Southbend Authorized Parts/Service Distributor list for the Authorized Parts supplier in  
your area. If this list is not available, call Southbend at 1-800-348-2558 to obtain this list.  
Parts for Simple Steam Countertop Steamer  
EZ-3 Part Number EZ-5 Part Number Description  
PH-422  
PH-422  
BELLEVILLE WASHER, 1/4 ID  
BLANK, DOOR HINGE  
1332076  
1178266  
1178651  
1178534  
1178525  
1178411  
1177770  
1178389  
1178494  
1175708  
1178276  
1178370  
1178299  
1178256  
1176561  
1161525  
1173448  
1332076  
1178266  
1178651  
1178534  
1178525  
1178411  
1177770  
BOX WELD ASM.,REAR  
BRACKET, COMPONENT SIMPLE  
BRACKET, ON/OFF SWITCH  
BRACKET, VENT TUBE  
BRACKET,WIRE HANGER  
BUSHING, VALVE LEVER MOUN  
BUSSMAN FUSE BLOCK,30A  
BUSSMAN FUSE BLOCK,60A 48  
BUZZER, ADJUSTABLE, 220V,  
CAM ACTUATOR, STEAMER  
CAVITY INSULATION  
1178494  
1175708  
1178276  
1181019  
1178256  
CAVITY WELD ASM  
CLAMP, HEATER  
CLEANING INSTRUCTIONS,RS-  
CONTACTOR, 2-POLE,240V,30  
CONTACTOR, 63A,240V COIL  
CONTACTOR, DP, 60 FLA  
CONTROL PANEL S/A  
1161525  
1181032  
1181042  
1178311  
1181038  
1178442  
1178524  
1178552  
1178397  
1178311  
CONTROL PANEL W/A  
CONTROLLER, EZ-5  
1178442  
1178524  
1178552  
COVER ASM.,POOL  
COVER W/A, DRAIN BOX  
COVER W/A, DRAIN  
OPERATORS MANUAL 1178387 REV 2  
PAGE 37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
Parts for Simple Steam Countertop Steamer  
EZ-3 Part Number EZ-5 Part Number Description  
1178265  
1178527  
1178255  
1178265  
1181000  
1181009  
1178657  
1179962  
COVER, BOTTOM  
COVER, REAR STEAMER  
COVER,EXTERIOR  
COVER,EXTERIOR,STACKED  
COVER,REMOVABLE BUSS  
DESCALER, 3.5OZ PKG (100G)  
DOOR ASSEMBLY COMPLETE  
DOOR INSUL.BLOCK  
1179962  
1176797  
1178167  
1178171  
1178522  
1178410  
1333045  
1178353  
1178359  
1178526  
1178656  
1178354  
1178360  
1178355  
1178361  
1178358  
1178364  
1178332  
1178423  
1178422  
PH-423  
1181015  
1178522  
1178410  
DRAIN BOX WELD ASM.  
DRAIN PAN WELD ASM.  
DRAIN VENT TUBE ( AIR VEN  
DUAL HEATING ELEMENT  
DUAL HEATING ELEMENT  
ELBOW, 90 DEG. 1"NPT FEM,  
ELBOW, 90 DEG, STR. 1/2"  
ELEMENT BLOCK, 220V,CENTE  
ELEMENT BLOCK, 220V,OUTER  
ELEMENT BLOCK, 240V,CENTE  
ELEMENT BLOCK, 240V,OUTER  
ELEMENT BLOCK, 480V,CENTE  
ELEMENT BLOCK, 480V,OUTER  
FITTING,3/4 HOSE ID X 1/2  
FITTING,3/4" KYNAR HOSE,E  
FITTING,FLOAT SWITCH  
FLANGE BUSHING, 1/4ID BRO  
FRONT FRAME WELD ASM  
FRONT TOP CROSSMEMBER W/A  
FUSE, 10 AMP  
1178670  
1178332  
1178422  
PH-423  
1178318  
1178317  
1178545  
1178392  
1178390  
1181020  
1178317  
1178545  
FUSE, 2.5 AMP  
FUSE, 30 AMP  
1181024  
FUSE, 35 AMP  
1178495  
FUSE, 50 AMP, CLASS G  
FUSE, 60 AMP  
1181026  
1178391  
1181010  
1178391  
1178096  
1178227  
1178325  
1180953  
1332048-1  
1332048-2  
FUSEBLOCK, CONTROLS  
GASKET, DOOR  
GASKET, SIDE PANEL  
1178325  
1180953  
1332048-1  
1332048-2  
1181041  
1178560  
1178561  
1178565  
1178562  
1178554  
1178555  
1178556  
1178559  
GASKET,CONTROL PANEL  
HANGER,HOSE  
HINGE, LT DOOR  
HINGE, RT DOOR  
HARNESS, WIRE, EZ-5  
HEAT ELEMENT,DUAL COIL,20  
HEAT ELEMENT,DUAL COIL,22  
HEAT ELEMENT,DUAL COIL,48  
HEAT/ELEMENT,240V,DUAL CO  
HEATING ELEMENT, 208V, EZ  
HEATING ELEMENT, 220V, EZ  
HEATING ELEMENT, 240V  
HEATING ELEMENT, 480V, EZ  
PAGE 38  
OPERATORS MANUAL 1178387 REV 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
PARTS  
Parts for Simple Steam Countertop Steamer  
EZ-3 Part Number EZ-5 Part Number Description  
1178483  
1178386  
HOSE, 1 1/2"ID,SILCONE  
HOSE,3/4" ID SILCONE  
HOSE, OVERFLOW, 28"  
INSULATION, BACK PANEL  
INSULATION, BOTTOM  
INSULATION,CAVITY,EZ-5  
INSULATION, DOOR, EZ-5  
INSULATION,FRONT CAVITY  
KIT, DRAIN BOXES,STACK  
KNOB  
1178386  
1178685  
1181021  
1178371  
1181022  
1181018  
1178418  
4440480  
1170337  
1175168  
1177079  
1177317  
1177078  
1181039  
1178485  
1178486  
1179930  
1178329  
1178330  
1175547  
1178374  
1178387  
1178367  
1178643  
1146402  
1177865  
1178369  
1178371  
1178418  
4440478  
1170337  
1175168  
1177079  
1177317  
1177078  
KNURLED INSERT, 3/8"  
LATCH ARM, CAST  
LATCH ASSEMBLY, STEAMERS  
LATCH COVER PLATE, CAST  
LEAD, ELEMENT EZ-5  
LEG,4" S/S, EZ (FRONT)  
LEG,4" S/S,EZ (REAR)  
LEVER, VALVE  
1178485  
1178486  
1178329  
1178330  
1175547  
1178374  
1178387  
1178367  
1178643  
LIGHT,INDICATING,AMBER  
LIGHT,INDICATING,RED  
LUG, GROUNDING  
MAIN POWER LEADS  
MANUAL, EZ-3&5 STEAMER  
METAL OXIDE VARISTOR  
NIPPLE, CLOSE, 1/2" NPT  
NUT 1/4-20, HEX HEAD  
NUT, HEX, 5/8 -18, BRASS  
NYLON INSERT NUT  
1178351  
PH-292  
PH-292  
NYLON WASHER  
1178342  
1178344  
1178345  
1178169  
1178105  
1178106  
1177081  
1178342  
1178344  
1178345  
1181017  
1181016  
1181001  
1177081  
1178393  
O-RING, VALVE SHAFT  
PAN Z-BRACKET,LEFT  
PAN Z-BRACKET,RIGHT  
PANEL ASM.,DOOR  
PANEL ASM.,INNER DOOR  
PANEL, GASKET RETAINER  
PIN, .250 DIA, SS, CAST L  
PIN,COTTER,SS,1/8"X 1 1/4  
PIPE ALUM,1" SCHEDULE 40  
PLUG BUTTON, 1/4 NYLON  
POLYPANEL W/TIMER  
POT FILLER  
1172949  
PM-141  
PM-141  
1178319  
1178684  
1178319  
1178684  
1178352  
1333041  
1178337  
1177086  
1178338  
6600402  
1178343  
1175712  
POTENTIOMETER,TDR  
RACK MOUNTING STUDS,1/4-2  
RELAY, TIME DELAY, 120V  
RETAINER, CAST LATCH  
RETAINING RING  
1333041  
1177086  
1178338  
6600402  
RING,RETAINING S.S.  
ROLL PIN  
1175712  
S/A BUZZER, 220V  
OPERATORS MANUAL 1178387 REV 2  
PAGE 39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
Parts for Simple Steam Countertop Steamer  
EZ-3 Part Number EZ-5 Part Number Description  
1178347  
1178347  
1178275  
1178373  
1177318  
SEAL,SHAFT  
SHAFT, VALVE LEVER  
SHIELD,HEAT TRANSFER  
SHIM, CAST STRIKER  
1178373  
1177318  
1178234  
SIDE PANEL,SIMPLE STEAM  
SIDE, RACK W/A  
1181045  
1172951  
1172951  
1178113  
1178644  
1179932  
1177082  
1178654  
1178655  
1178379  
1177080  
1178270  
1178340  
1178533  
1178430  
SLEEVE, RUBBER 1 1/4"ID X  
SLIDE RACK, 3 PAN STEAMER  
SLIDE RACK, 5 POS. 3 PAN  
SPRING  
1179932  
1177082  
1178654  
1178655  
1178379  
1177080  
1178270  
1178340  
1178533  
1178430  
1181013  
1181012  
SPRING, DOOR HANDLE  
STAND W/DRAIN, EZ  
STAND, EZ  
STEAM TRAP  
STRIKER, CAST  
SWITCH ACTUATOR ROD  
SWITCH, FLOAT  
SWITCH, POWER S/A  
SWITCH,DOOR S/A,SIMPLE ST  
THERMOSTAT ASSEMBLY, F/F  
THERMOSTAT ASSEMBLY, M/M  
THERMOSTAT, ELEMENT, 2001  
TIMER, MECHANICAL  
1174302  
1178341  
1176388  
1178439  
1178261  
1178376  
1178388  
1178425  
1178444  
1176878  
1178341  
1176388  
1178439  
1178261  
1178376  
1178388  
1178425  
1178444  
TRANSFORMER, 480 TO 240,7  
TROUGH SCREEN ASM.  
TUBE & BOX TOP W/A  
TUBE, VALVE ACTUATOR  
VALVE LEVER WELD ASM  
VALVE, 1/2" DRAIN,MODIFIE  
VALVE, 3/8" BALL,NSF/FDA  
VENT PIPE, 1" NIPPLE  
VENT PIPE, 1" X 24.375"  
WASHER, SEALING, #10  
WATER TROUGH W/A  
WIRE HARNESS SUPPL., 480V  
WIRE HARNESS W/DISC TSTAT  
WIRING, DIAGNOSTIC, 480V  
WIRING, DIAGNOSTIC,208/22  
1178683  
1180460  
1178324  
1178652  
1178394  
1178650  
1178395  
1178324  
1181043  
1181040  
1181037  
PAGE 40  
OPERATORS MANUAL 1178387 REV 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS  
LIMITED WARRANTY  
Southbend warrants that the equipment, as supplied by the factory to the original purchasers, is free from defects in  
materials and workmanship. Should any part thereof become defective as a result of normal use within the period and  
limits defined below, then at the option of Southbend such parts will be repaired or replaced by Southbend or its  
Authorized Service Agency. This warranty is subject to the following conditions:  
Repairs under this warranty are to be performed by a Southbend Authorized Service Agency. Southbend cannot be  
responsible for charges incurred or service performed by non-Southbend Authorized Agencies. In all cases the closest  
Southbend Authorized Service Agency must be used.  
TIME PERIOD:  
One year labor, one year parts effective from the date of original purchase. The authorized service agency may at his  
option require proof of purchase.  
Exceptions to standard warranty, effective within above limitations:  
• Glass Windows, Door Seals, Rubber Seals, Light Bulbs, Ceramic Bricks,  
• Sight Glasses, Cathodic Descalers or Anodes, Broiler, Briquettes and Drip Shields....... 90 days material and labor  
• Stainless Steel Fry Pot................................................4 years extended material warranty on fry pot only—no labor  
• Stainless Steel Open Top Burners........................... 4 years extended material warranty on burners only—no labor  
• Pressure Steam Boiler Shell.............................. Prorated 4 years extended warranty on boiler shell only—no labor  
Boiler shells which have not been properly maintained will not be covered by warranty.  
In all cases, parts covered by a five year warranty will be shipped FOB the factory after the first year.  
EXCLUSIONS:  
• Equipment failure relating to improper installation. Examples are: improper utility connection, improper utilities supply  
and problems due to ventilation.  
• Equipment that has not been properly maintained. Examples are: calibration of controls, adjustments to pilots and  
burners, damage from improper cleaning, and water damage to controls.  
• Equipment that has not been used in an appropriate manner, or has been subject to misuse or misapplication,  
neglect, abuse, accident, damage during transit or delivery, fire, flood, riot, or act of God.  
If the equipment has been changed, altered, modified or repaired by other than a qualified service technician during or  
after the one year limited warranty period, then the manufacturer shall not be liable for any damages to any person or to  
any property which may result from the use of the equipment thereafter.  
Equipment failure caused by inadequate water quality is not covered under warranty. WATER QUALITY must not exceed  
the following limits: Total Dissolved Solids (TDS) - 60 PPM (Parts Per Million). Hardness - 2 Grains or 35 PPM, PH  
Factor - 7.0 to 7.5. Water pressure 30 PSI minimum, 60 PSI maximum. Boiler maintenance is the responsibility of the  
owner and is not covered by warranty.  
This warranty does not cover services performed at overtime or premium labor rates nor does Southbend assume any  
liability for extended delays in replacing or repairing any items in the equipment beyond the control of Southbend.  
"Southbend shall not be liable for consequential or special damages of any nature that may arise in connection with such  
product or part." Should service be required at times which normally involve overtime or premium labor rates, the owner  
shall be charged for the difference between normal service rates and such premium rates.  
This warranty only covers product shipped into the 48 contiguous United States and Hawaii. There will be no labor  
coverage for equipment located on any island not connected by roadway to the mainland.  
This equipment is intended for commercial use only. Warranty is void if equipment is installed in other than commercial  
application.  
Warranty on all replacement parts which are replaced in the field by Southbend Authorized Service Agencies will be  
limited to three months on labor, six months on materials (parts) effective from the date of installation. See LIMITED  
WARRANTY - REPLACEMENT PARTS for conditions and limitations.  
"THE FOREGOING WARRANTY IS IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESSED OR IMPLIED  
INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS, AND CONSTITUTES THE ENTIRE  
LIABILITY OF SOUTHBEND. IN NO EVENT DOES THE LIMITED WARRANTY EXTEND BEYOND THE DURATION  
OF ONE YEAR FROM THE EFFECTIVE DATE OF SAID WARRANTY."  
OPERATORS MANUAL 1178387 REV 2  
PAGE 41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
COUNTERTOP STEAMER  
A product with the Southbend name incorporates the best in durability and low maintenance. We  
all recognize, however, that replacement parts and occasional professional service may be  
necessary to extend the useful life of this unit. When service is needed, contact a Southbend  
Authorized Service Agency, or your dealer. To avoid confusion, always refer to the model number,  
serial number, and type of your unit.  
Southbend  
1100 Old Honeycutt Road, Fuquay-Varina, NC 27526  
(800) 348-2558 or (919) 552-9161 FAX (800) 348-2558 or (919) 552-9798  
PAGE 42  
OPERATORS MANUAL 1178387 REV 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sharper Image Refrigerator KP W140 User Manual
Sony Car Amplifier TA P9000ES User Manual
Sony Carrying Case LCS BP1BP User Manual
Sony Car Stereo System XR L240 User Manual
Sony Personal Computer PCV 1 1 1 6 User Manual
Sony Personal Computer PCV E204 User Manual
Southbend Hot Beverage Maker KDLS 100 User Manual
Sterling Dehumidifier 90 225 CFM User Manual
Sterling Plumbing Outdoor Shower 71140115 User Manual
Tanaka Edger TPE 2510 User Manual