3-620-374-11 (1)
Network Camera
User’s Guide
Software Version 1.0
SNC-RZ30N/RZ30P
© 2002 Sony Corporation
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTICE TO USERS
© 2002 Sony Corporation. All rights reserved. This
manual or the software described herein, in whole or in
part, may not be reproduced, translated or reduced to
any machine readable form without prior written
approval from Sony Corporation.
SONY CORPORATION PROVIDES NO
WARRANTY WITH REGARD TO THIS MANUAL,
THE SOFTWARE OR OTHER INFORMATION
CONTAINED HEREIN AND HEREBY EXPRESSLY
DISCLAIMS ANY IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR ANY
PARTICULAR PURPOSE WITH REGARD TO THIS
MANUAL, THE SOFTWARE OR SUCH OTHER
INFORMATION. IN NO EVENT SHALL SONY
CORPORATION BE LIABLE FOR ANY
INCIDENTAL, CONSEQUENTIAL OR SPECIAL
DAMAGES, WHETHER BASED ON TORT,
CONTRACT, OR OTHERWISE, ARISING OUT OF
OR IN CONNECTION WITH THIS MANUAL, THE
SOFTWARE OR OTHER INFORMATION
CONTAINED HEREIN OR THE USE THEREOF.
Sony Corporation reserves the right to make any
modification to this manual or the information contained
herein at any time without notice.
The software described herein may also be governed by
the terms of a separate user license agreement.
“Memory Stick” is a trademark of Sony Corporation.
Microsoft, Windows, Internet Explorer and MS-DOS
are registered trademarks of Microsoft Corporation in
the United States and/or other countries.
Netscape and Navigator are registered trademarks of
Netscape Communications Corporation in the U.S. and
other countries.
Java is a trademark of Sun Microsystems, Inc. in the
United States and other countries.
MMX and Pentium are registered trademarks of Intel
Corporation or its subsidiaries in the United States and
other countries.
All other company and product names are trademarks or
registered trademarks of the respective companies or
their respective makers.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Checking the Preset Position Settings
Programming the Tour
Table of Contents
Checking the Tour Settings
Activating/Deactivating the FTP Client Function
Setting the FTP Client Function
Activating/Deactivating the FTP Server Function
Setting the FTP Server Function
Sending an Image via E-mail
Activating/Deactivating the SMTP Function
Setting the SMTP Function
Recording a Still Image on an ATA Memory Card
Setting the Alarm Out 1 or 2
Activating/Deactivating the Alarm Out 1 Function
Setting the Alarm Out 1 Function
Activating/Deactivating the Image Memory
— Image memory usage setting Page ............35
Recording an Image in the Selected Memory
Configuring the Network
Activating/Deactivating the Security Function
Setting the Security Function
Setting the Camera Position and Action
Setting the Alarm Buffer
Communicating Data via Serial Port
Setting the Activity Detection Function
Storing the Pan, Tilt and Zoom Positions
4
Table of Contents
Download from Www.Somanuals.com. All Manuals Search And Download.
Assigning the IP Address Using the Setup
Assigning the IP Address to the Camera Using
5
Table of Contents
Download from Www.Somanuals.com. All Manuals Search And Download.
Overview
Precautions
This Sony product has been designed with safety in
mind. However, if not used properly electrical products
can cause fires which may lead to serious body injury.
To avoid such accidents, be sure to heed the following.
How to Use This User’s
Guide
This User’s Guide explains how to operate the SNC-
RZ30N/RZ30P Network Camera from a computer.
The User’s Guide is written to be read on the computer
display.
Heed the safety precautions
Be sure to follow the general safety precautions and the
“Operating Precautions.”
In case of a breakdown
In case of system breakdown, discontinue use and
contact your authorized Sony dealer.
As this section gives tips on using the User’s Guide, read
it before you operate the camera.
Jumping to the related page
When you read the User’s Guide on the computer
display, click on the sentence to jump to the related page.
In case of abnormal operation
• If the unit emits smoke or an unusual smell,
• If water or other foreign objects enter the cabinet, or
• If you drop the unit or damage the cabinet:
Software display examples
Note that the displays shown in the User’s Guide are
explanatory examples. Some displays may be different
from the ones which appear as you operate the
application software.
1
2
Disconnect the camera cable and the connecting
cables.
Contact your authorized Sony dealer or the store
where you purchased the product.
Printing the User’s Guide
Depending on your system, certain displays or
illustrations in the User’s Guide, when printed out, may
differ from those as portrayed on your screen.
Operating Precautions
Operating or storage location
Avoid operating or storing the camera in the following
locations:
• Extremely hot or cold places (Operating temperature:
0°C to +40°C [32°F to 104°F])
• Exposed to direct sunlight for a long time, or close to
heating equipment (e.g., near heaters)
• Close to sources of strong magnetism
• Close to sources of powerful electromagnetic
radiation, such as radios or TV transmitters
Installation Manual (printed matter)
The supplied Installation Manual describes the names
and functions of parts and controls of the Network
Camera, connecting examples and how to set up the
camera. Be sure to read the Installation Manual before
operating.
Transportation
When transporting the camera, repack it as originally
packed at the factory or in materials of equal quality.
Cleaning
• Use a blower to remove dust from the lens or optical
filter.
• Use a soft, dry cloth to clean the external surfaces of
the camera. Stubborn stains can be removed using a
soft cloth dampened with a small quantity of detergent
solution, then wipe dry.
• Do not use volatile solvents such as alcohol, benzene
or thinners as they may damage the surface finishes.
6
How to Use This User’s Guide / Precautions
Download from Www.Somanuals.com. All Manuals Search And Download.
Note
Operating the Camera
To operate the welcome page correctly, set the security
level of the Internet Explorer to Medium or lower, as
follows:
The Operating the Camera section explains how to
monitor the image from the camera using the Web
browser. For setting the camera, see “Administrating the
1
2
3
Select Tool from the menu bar of Internet Explorer,
then select Internet Options and Security tab in
sequence.
Click the Internet icon (when using the camera via
the Internet) or Local intranet icon (when using
the camera via a local network).
Logging in to Homepage
— Welcome Page
Set the slider to Medium or lower. (If the slider is
not displayed, click Default Level.)
Logging in as a User
Logging in as Administrator
1
Start the web browser on the computer and type the
IP address of the camera you want to monitor.
If you log in the camera as the Administrator, you can
perform all the settings provided with the software. The
Administrator may be logged in at any time, regardless
of the number of the users being accessed.
1
Click Administrator on the welcome page.
The login page appears.
The welcome page of Network Camera SNC-
RZ30 is displayed.
2
Enter the user name and password for
Administrator, then click OK.
The user name “admin” and the password “admin”
are set as default settings for the Administrator.
You can change them on the User setting page in the
2
Click to select the viewer.
You can select the viewer from among Java applet
viewer, ActiveX viewer and Server push viewer,
whichever is suitable for your system environments
and usage.
For details, see “About Viewers” on page 8.
When you have selected the viewer, the main
7
Logging in to Homepage — Welcome Page
Download from Www.Somanuals.com. All Manuals Search And Download.
The welcome page is changed to that for
Administrator.
If you are using Internet Explorer
Select Tool from the menu bar of Internet Explorer, then
select Internet Option and the Advanced tab in
sequence, and check JIT compiler for virtual machine
enabled (requires restart). Then restart Internet
Explorer.
If you are going to install Netscape
Install Java in the process of Netscape installation,
following the instructions of the installer.
After installing, select Edit from the menu bar of
Netscape, then Setting and Details for category in
sequence, and check Activate Java.
If you are using Netscape without Java installed
Install Java from the Plug-in Download Page of
Netscape.
If you are using Netscape with Java installed,
but the viewer does not operate correctly
Download Java 2 Runtime Environment, Standard
Edition (JRE) from Netscape Netcenter or Sun
HomePage, and install it following the intructions of the
installer. After installing, select Edit from the menu bar
of Netscape, then Setting and Details for category in
sequence, and check Activate Java.
3
Select the viewer.
You can select the viewer from among Java applet
viewer, ActiveX viewer and Server push viewer,
whichever is suitable for your system environments
and usage.
When you have selected the viewer, the main
ActiveX viewer
The ActiveX viewer operates on Internet Explorer.
It displays the main viewer page using ActiveX.
With this viewer, you can display images at a high frame
rate and use all the functions provided with this
software.
Other functions on the welcome page for
Administrator
Setting
ActiveX Control is automatically installed to your
computer when you log in the camera using Internet
Explorer for the first time.
Home
Click to return to the normal welcome page.
Server push viewer
The Server push viewer operates on Netscape.
When you select this viewer, the main viewer page is
displayed through the Server push technology which the
Netscape supports as standard.
About Viewers
You can select one of the following three viewers.
This viewer allows image display at a high frame rate.
Java applet viewer
The Java applet viewer operates on Internet Explorer or
Netscape.
Notes
• When you use the Server push viewer, the time
display, pop-up display and image size selection do
not operate. As the image rotation does not operate,
the camera image is always upside down when the
camera is installed on a desk top.
• If you display a large size image such as VGA with a
high frame rate using the Server push viewer, the
computer may freeze. Change Frame rate on the
computer performance.
It displays the main viewer page using Java.
With this viewer, you can use all the functions provided
with this software.
Notes
• The frame rate is lower than that for the other viewers.
• If the viewer does not operate correctly, install or
activate Java as follows:
8
Logging in to Homepage — Welcome Page
Download from Www.Somanuals.com. All Manuals Search And Download.
Tip
Every page of this software is optimized as display
character size Medium for Internet Explorer, or 100%
for Netscape.
Configuration of Main
Viewer Page
When you select the viewer, the main viewer page is
displayed.
This section briefly explains the functions of the parts
and controls on the main viewer page. For a detailed
explanation on each part or control, see the specified
pages.
Main viewer page
Image control section
Monitor image
Menu section
Menu Section
The available functions are limited by user access right.
You can change user access right on the User setting
Control
Displays the camera control parts on the image control
User access right Level 2 to Level 4 is required for this
function.
Capture
Captures a still image shot by the camera and stores it in
the computer. (See “Capturing a Monitor Image” on
9
Configuration of Main Viewer Page
Download from Www.Somanuals.com. All Manuals Search And Download.
Trigger control parts
These parts are displayed when you click Trigger on the
menu section. You can output a trigger using these parts.
Trigger
Displays the trigger control parts on the image control
section.
By clicking the trigger button, you can control various
User access right Level 3 or Level 4 is required for this
function.
Setting
Displays the Administrator menu. (See “Configuration
User access right Level 4 is required for this function.
Home
Displays the Welcome page.
Image Control Section
Camera control parts
Trigger control parts
Frame rate
Selects the frame rate to transmit images.
View size
Selects the image size to be displayed.
Camera control parts
These parts are displayed when you click Control on the
menu section. You can operate the camera using these
parts.
10
Configuration of Main Viewer Page
Download from Www.Somanuals.com. All Manuals Search And Download.
Controlling the Monitor
Image
You can control the monitor image from the image
control section on the main viewer page.
Operating the Camera
You can operate the camera from the image control
section on the main viewer page.
For this function, user access right Level 2 to Level 4 is
Image control section
Click
Control on the menu section to display the
camera control parts.
Image control section (camera control parts)
Selecting the frame rate
Click the down-arrow button in the Frame rate box and
select the frame rate with which the images are
transmitted, from the drop-down list.
You can select the frame rate from among the following:
SNC-RZ30N:
1, 2, 3, 4, 5, 6, 8, 10, 15, 20, 25, Fastest
SNC-RZ30P:
1, 2, 3, 4, 5, 6, 8, 12, 16, 20, Fastest
The numbers indicate “FPS” (the number of frames
transmitted per second).
With Fastest, the camera transmits the maximum
number of frames possible for the connected line. The
maximum frame rate is 30 FPS for the SNC-RZ30N and
25 FPS for the SNC-RZ30P.
Panning and Tilting
Note
You can pan and tilt the camera using the 8-direction
arrow buttons or the tablet.
The frame rate options indicate the maximum number of
frames that can be transmitted. The number of frames
actually transmitted may vary depending on the network
environments and camera settings (image size and
image quality settings).
Setting the pan/tilt mode
Click
. Each click alternates the 8-direction
arrow mode and the tablet mode.
Selecting the view size
Click the down-arrow button in the View size box and
select the view size from the drop-down list.
You can select the view size from among the following:
Panning and tilting using the 8-direction
arrow buttons
Auto, 640 × 480, 320 × 240, 160 × 120
Auto is determined by the image size specified with
Observe the monitor image and click the arrow button
indicating the direction in which you want to move the
camera. The camera moves and the monitor image
follows.
11
Controlling the Monitor Image / Operating the Camera
Download from Www.Somanuals.com. All Manuals Search And Download.
Hold down the arrow button to move the direction of the
camera continuously.
Click
default position.
to return the camera to the factory-preset
When the Zoom mode menu on the Camera setting page
is set to Optical only, clicking this button operates the
electronic ×2 zoom.
The button name changes to DZOOM x 1.
Note
If the Exclusive control mode menu on the System
operation time is displayed instead of
.
When the Zoom mode menu on the Camera setting page
is set to Optical only, this button is displayed while the
electronic ×2 zoom is operating. Clicking this button
cancels the electronic ×2 zoom.
Panning and tilting using the tablet
The button name changes to DZOOM x 2.
About the zoom range
When the Zoom mode menu on the Camera setting page
magnification zoom, optical zoom of × 25 and electronic
zoom of × 12, giving × 300 in total. The electronic zoom
will operate after the optical zoom.
When the Zoom mode menu is set to Optical only, only
optical zoom of × 25 can operate. In this case, you can
use an electronic zoom of × 2 by clicking the DZOOM
x 2 button. To cancel the electronic zoom, click
DZOOM x 1.
When you click PT MODE, the 8-direction arrow
buttons change to a tablet. The tablet represents the
monitor image.
A click on the tablet moves the direction of the camera
so that the clicked position goes to the center of the
monitor image.
If you want to change the direction of the camera further,
click on the tablet and drag in the direction in which you
want to move the camera. The direction of the camera
moves as you drag. Hold down the button to move the
direction of the camera continuously.
Note
When you have changed the Zoom mode menu on the
Camera setting page, click the Control button on the
menu section to update the zoom mode setting on the
image control section.
Notes
Focusing
• The tablet represents the whole monitor image even
when you have trimmed the monitor image using the
Area setting menu on the Camera setting page (see
• If the Exclusive control mode menu on the System
operation time is displayed on the lower right corner
of the tablet.
When the Focus mode menu on the Camera setting page
manually from the image control section, or adjust it
with a push of the button.
Adjust the focus manually by clicking the two buttons
alternately.
Zooming
Click this button to adjust the focus instantly.
CIick to zoom in.
Click to zoom out.
Notes
• When you have changed the Focus mode menu on the
Camera setting page, click the Control button on the
menu section to update the focus mode setting on the
image control section.
• If the NEAR, FAR and ONE PUSH AF buttons are not
displayed, click the FOCUS button on the image
12
Operating the Camera
Download from Www.Somanuals.com. All Manuals Search And Download.
control section. The three buttons appear and the
FOCUS button name changes to PRESET.
Controlling the
Application Manually
Moving the Camera to the Preset
Position
You can send an image or output a trigger to control the
alarm output, using the image control section on the
main viewer page.
For this function, user access right Level 3 or Level 4 is
When you click this button, the PRESET list box
appears.
The PRESET button name changes to FOCUS.
Click
Trigger on the menu section to display the
trigger control parts.
PRESET list box
Image control section (trigger control parts)
Click the down-arrow button and select the preset
position name from the drop-down list. Then, the
camera will move to the preset position that you have
stored in memory using the Preset position setting page
Sending a Still Image File to an FTP
Server
If you select FTP send and click
, the current still
image is captured and the captured image file is sent to
the FTP server specified on the FTP client setting page.
To use this function, you need to select the Use FTP
client function option and the Manual mode on the
FTP client setting page.
For details, see “Sending Images to FTP Server — FTP
Note
If the camera is installed on a desk top, the sent still
image is upside down.
Sending a Still Image via E-mail
If you select Mail send and click
, the current still
image is captured and an E-mail with the captured image
file attached is sent to the E-mail address(es) specified
on the SMTP setting page.
To use this function, you need to select the Use SMTP
function option and the Manual mode on the SMTP
setting page.
For details, see “Sending an Image via E-mail — SMTP
13
Controlling the Application Manually
Download from Www.Somanuals.com. All Manuals Search And Download.
Note
Capturing a Monitor
Image
If the camera is installed on a desk top, the sent still
image is upside down.
If you click the
Capture button on the menu section,
Recording a Still Image on an ATA
Memory Card or the Built-in
Memory of the Camera
the current still image is captured and displayed on the
monitor image section.
If you select Memory save and click
, the current
still image is captured and stored in the memory
specified on the Image memory setting page.
To use this function, you need to select the Use image
memory function option and the Manual mode on the
Image memory setting page.
For details, see “Recording Images in Memory — Image
Note
If the camera is installed on a desk top, the recorded still
image is upside down.
Controlling Alarm Output
If you select Alarm out 1 or Alarm out 2 and click
,
you can control alarm out 1 or alarm out 2 of the I/O port
on the camera manually. Each click switches the relay
between short-circuit and open alternately.
To use this function, you need to select the Use alarm
out 1 (or 2) function option and the Manual mode on
the Alarm out 1 or Alarm out 2 setting page.
Note
If the camera is installed on a desk top, the captured still
image is upside down.
To save the captured image
For details, see “Setting the Alarm Out 1 or 2 — Alarm
Right-click on the monitor image and select Save As
from the menu. Then, the Save Picture dialog appears.
Type the file name and specify the destination to which
the image file is to be stored, and click Save. The image
is saved in the JPEG format.
For the connection of peripheral devices to the Alarm
out of the I/O port, see the supplied Installation Manual.
14
Capturing a Monitor Image
Download from Www.Somanuals.com. All Manuals Search And Download.
Network
Administrating the Camera
Displays the Network (Ethernet) setting page.
The Administrating the Camera section explains how to
set the functions of the camera by the Administrator.
For monitoring the camera image, see “Operating the
User
Displays the User setting page.
Security
Displays the Security setting page.
Configuration of
Administrator Menu
Page
Application menu
The Administrator menu page is displayed when the
Administrator having Level 4 access right selects
Setting on the welcome page for Administrator, or when
Preset position
Displays the Preset position setting page.
the
Setting button on the menu section of the main
viewer page is clicked.
FTP client
Displays the FTP client setting page.
FTP server
Displays the FTP server setting page.
SMTP
Displays the SMTP setting page.
Alarm out 1
Displays the Alarm out 1 setting page.
The Administrator menu consists of the Basic menu and
the Application menu. The Basic menu is used for basic
settings of the camera, and the Application menu is used
for setting various applications according to individual.
Click on each menu name to display its setting page.
Alarm out 2
Displays the Alarm out 2 setting page.
Basic menu
System
Image memory
Displays the System setting page.
Displays the Image memory setting page.
Camera
Alarm buffer
Displays the Camera setting page.
Displays the Alarm buffer setting page.
15
Configuration of Administrator Menu Page
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial
Displays the Serial setting page.
Configuring the System
— System setting Page
When you click System on the Administrator menu, the
System setting page appears.
Use this page to perform the principal settings of the
software.
Schedule
Displays the Schedule setting page.
Activity detection
System setting Section
Displays the Activity detection setting page.
Pop-up
Displays the Pop-up setting page.
Buttons common to every setting page
The following buttons are displayed on the setting pages
where they are necessary. The functions of the buttons
are the same on every setting page.
Click this button to validate the settings.
Click this button to invalidate the set values and return to
the previous settings.
Click this button to return to the top of the setting page.
Title bar name
Type a name to display on the title bar up to 32
characters.
Welcome text
Type a text to show on the welcome page, in HTML
format, up to 1,024 characters. Use the <BR> tag for a
line break. (A line break is equivalent to 2 characters.)
Serial No.
Displays the serial number of the camera.
Default frame rate
Select the initial frame rate which is selected when you
log in the camera and display the main viewer page.
Click the down-arrow button in the box and select the
frame rate from the drop-down list.
16
Configuring the System — System setting Page
Download from Www.Somanuals.com. All Manuals Search And Download.
The selectable frame rates are the following:
SNC-RZ30N:
1, 2, 3, 4, 5, 6, 8, 10, 15, 20, 25, Fastest
SNC-RZ30P:
1, 2, 3, 4, 5, 6, 8, 12, 16, 20, Fastest
The numbers indicate “FPS” (the number of frames
transmitted per second).
With Fastest, the camera transmits the maximum
number of frames possible for the connected line. The
maximum frame rate is 30 FPS for the SNC-RZ30N and
25 FPS for the SNC-RZ30P.
A-slot (advr)/B-slot (bdrv)
Displays the type of the PC card inserted into the PC
card slot and its free card space. The PC card slot located
on the lens side is “A-slot,” and that on the camera
bottom side is “B-slot.”
Exclusive control mode
Limits the pan/tilt operation of the camera.
If you select Off, multiple users can pan/tilt the camera
at the same time. The operation by the user accessed
later has priority.
If you select On, only one user can pan/tilt the camera.
The period of operation allowed to one user is
determined by the Operation time setting. If a user tries
to operate the camera while another user is operating it,
the control right is limited according to the Operation
time and Maximum wait number settings.
Note
To update the main viewer page for the changed setting,
click Refresh of the browser.
Mount
Select Ceiling when you install the camera on the
ceiling, or Desk top when you install it on a desk top.
Operation time
Sets the period that one user can operate the camera
exclusively, between 10 and 600 sec.
This setting is valid when the Exclusive control mode
menu is set to On.
Notes
• To update the main viewer page for the changed
setting, click Refresh of the browser.
• This function is inactive when you use the Server push
viewer.
Maximum wait number
Sets the maximum number of users that can wait to
control the camera while another user is operating the
camera. The selectable number is between 0 and 20.
This setting is valid when the Exclusive control mode
menu is set to On.
Default URL
Select the homepage to be displayed when you enter the
IP address of the camera in the Address box of the
browser.
System log
Click View to display the Log file events page.
The Log file events page shows the software version and
troubleshooting information.
To display the homepage built in the camera
Select /index.html.
To display your individual homepage
You can display the favorite homepage if you create it
using the CGI commands of the camera and store the
HTML file in the recommended ATA memory card. In
this case, change the Default URL setting as follows:
Date time setting Section
1
2
Select User Setting.
Store the HTML file of the homepage you created
into an ATA memory card and insert the card into
the PC card slot of the camera.
The PC card slot located on the lens side is “A slot,”
and that on the camera bottom side is “B slot.”
3
4
Select from the drop-down list, /adrv/ when you
have inserted the PC card into A slot, or /bdrv/
when you have inserted it into B slot.
Current date time
Displays the date and time set on the camera.
You can set the date and time using the following two
methods.
Type the path of the homepage up to 64 characters.
17
Configuring the System — System setting Page
Download from Www.Somanuals.com. All Manuals Search And Download.
Click Factory default, and “All configuration
information will be initialized as factory setting. Are
you sure?” appears. Click OK to reset to the factory
settings.
Note
When you purchased the camera, be sure to check the
date and time of the camera and set them if necessary.
System (PC) current date time
Displays the date and time set on your computer.
Click Apply to transfer the computer’s date and time to
the camera.
The set date and time are shown on Current date time.
Manual current date time
When you want to set the camera’s date and time
manually.
Select the lower 2-digits of the year, month, date, hour,
minutes and seconds from each drop-down list. Click
Apply to change the Current date time setting to the date
and time you selected.
Time zone selecting
Set the time difference from Greenwich Mean Time in
the area where the camera is installed. When you send
an E-mail, the senting date and time is adjusted
according to this setting.
Select the time zone where the camera is installed from
the drop-down list. Click Apply to change the Current
date time setting according to the selection.
Notes
• If the time zone selected on the Time zone selecting
menu is different from that set on the computer, the
time is adjusted using the time zone difference and set
on the camera.
• Due to the network properties, there may be a slight
difference between the actual time and the time set on
the camera.
Date time format
Select the format of date and time to be displayed on the
monitor image from the drop-down list.
You can select from among yyyy-mm-dd hh:mm:ss
(year-month-day hour:minute:second), mm-dd-yyyy
hh:mm:ss (month-day-year hour:minute:second), and
dd-mm-yyyy hh:mm:ss (day-month-year
hour:minute:second).
Click Apply to transfer the setting to the camera.
Reboot
Reboots the camera.
Click Reboot, and “The SNC-RZ30 will be rebooted.
Are you sure?” appears. Click OK to reboot the camera.
Factory default
Resets the camera to the factory settings.
18
Configuring the System — System setting Page
Download from Www.Somanuals.com. All Manuals Search And Download.
Tip
The following table shows the relation between the data
size of a 24-bit image (8 bits for each R, G and B), and
the compression rate for each Level setting.
(in case of 640 × 480 image)
Setting the Camera
— Camera setting Page
When you click Camera on the Administrator menu,
the Camera setting page appears.
Use this page to set the functions of the camera.
Level
Data size (approx.)
Compression rate
(approx.)
1
2
3
4
5
6
7
8
9
10
15 KB
18 KB
22.5 KB
25.7 KB
30 KB
36 KB
45 KB
60 KB
90 KB
180 KB
1/60
1/50
1/40
1/35
1/30
1/25
1/20
1/15
1/10
1/5
Note
To update the camera for the changed setting, click
Apply on the changed item.
Upper Half of Camera setting Page
Image
Select Color or Monochrome.
Area setting
When the image size is 736 × 480 or 640 × 480 for the
SNC-RZ30N, or 736 × 544 or 640 × 480 for the SNC-
RZ30P, you can trim a portion of the image and display
the trimmed image on the computer. With the trimming,
the transmitting data size, and thus, the network load is
reduced and a higher frame rate is obtained.
Select On for trimming the image, or Off for no
trimming.
Image size
Select the size of the image to be transmitted to the
computer.
You can select from among the following options.
SNC-RZ30N:
To trim an image
736 × 480 (Auto), 736 × 480 (Frame), 736 × 480
(Field), 640 × 480 (Auto), 640 × 480 (Frame), 640 ×
480 (Field), 320 × 240, 160 × 120
1
Set the Image size menu to 736 × 480 or 640 × 480
for the SNC-RZ30N, or 736 × 544 or 640 × 480 for
the SNC-RZ30P.
SNC-RZ30P:
736 × 544 (Auto), 736 × 544 (Frame), 736 × 544
(Field), 640 × 480 (Auto), 640 × 480 (Frame), 640 ×
480 (Field), 320 × 240, 160 × 120
Frame is suitable for still images, and Field is suitable
for animation.
2
3
Set the Area setting menu to On, and click Apply.
Click the Area setting button.
A still image is displayed.
If you select Auto, the image mode changes between
Frame and Field automatically: Frame when the
subject is a still object, and Field when the subject is
moving.
Image quality
Select the image quality from Level 1 to Level 10.
A higher level gives a higher image quality, but the
frame rate decreases as the data size increases.
19
Setting the Camera — Camera setting Page
Download from Www.Somanuals.com. All Manuals Search And Download.
4
Click on the still image to specify the trimming
portion.
A red frame that appears when you clicked
indicates the trimming portion.
The trimming portion is determined as shown
below:
White balance mode
Select the white balance mode.
You can select from among Auto, Indoor, Outdoor,
One push WB, ATW and Manual.
If you select One push WB, the ONE PUSH
TRIGGER button is displayed. Click the button to
adjust the white balance instantly.
Point rotated by 180° around the
axis of the center of the still image
If you select Manual, the R Gain and B Gain controls
are displayed. Set 0 to 255 for each control.
Still image
Lower Half of Camera setting Page
Red trimming
frame
Center of the Clicked point
still image
To change the trimming portion, click on another
point on the image.
5
6
Click OK at the bottom of the window.
The trimmed image is displayed on the main viewer
page.
To close the image, click
corner.
on the upper-right
Exposure mode
Zoom mode
Select the zoom mode.
Select the exposure from among Full auto, Shutter
priority, Iris priority and Manual.
The setting items required for each setting appear.
Select Full to operate the optical zoom of × 25 and the
electronic zoom of × 12, giving × 300 in total. The
electronic zoom will operate after the optical zoom.
Select Optical only to operate the optical zoom of × 25
only. In this case, you can use an electronic zoom of × 2
by clicking the DZOOM x 2 button on the main viewer
page. To cancel the electronic zoom, click the DZOOM
x 1 button. (See “Zooming” on page 12.)
Full auto: Adjusts the exposure automatically using the
electronic shutter, iris and gain. Select the Back light
compensation menu On or Off.
Shutter priority: Adjusts the exposure automatically
using the iris and gain. Select the electronic shutter
speed from the Shutter drop-down list.
Focus mode
Select the focus mode.
Select Auto to adjust the focus automatically.
Select Manual to adjust the focus manually using the
NEAR and FAR buttons on the main viewer page. If you
click the ONE PUSH AF button, the focus is adjusted
instantly. (See “Focusing” on page 12.)
Iris priority: Adjusts the exposure automatically using
the electronic shutter and gain. For the iris
adjustment, select the F number from the Iris drop-
down list.
Manual: Select the electronic shutter, iris and gain from
the drop-down list for each control.
Back light compensation
Select On to activate the backlight compensation, or Off
to deactivate it.
20
Setting the Camera — Camera setting Page
Download from Www.Somanuals.com. All Manuals Search And Download.
Shutter
Note
Select the electronic shutter speed from among the
following:
SNC-RZ30N:
The Contrast setting is effective for the computer image
only. (It is not effective for the video signal output.)
1/10000, 1/6000, 1/4000, 1/3000, 1/2000, 1/1000,
1/725, 1/500, 1/350, 1/250, 1/180, 1/125, 1/100, 1/90,
1/60, 1/30, 1/15, 1/8, 1/4, 1/2, 1 (seconds).
SNC-RZ30P:
1/10000, 1/6000, 1/3500, 1/3000, 1/2500, 1/1750,
1/1000, 1/600, 1/420, 1/300, 1/215, 1/150, 1/120, 1/100,
1/75, 1/50, 1/25, 1/12, 1/6, 1/3, 1/2, 1 (seconds).
Stabilizer
Select the stabilizer to compensate oscillation.
Select On to activate the stabilizer when the camera is
exposed to oscillation.
Normally select Off.
Notes
Iris
• If you pan or tilt the camera with the Stabilizer menu
set to On, it will take about 5 seconds until the monitor
image becomes stable after panning or tilting.
• The stabilizer was developed in order to compensate
the oscillation generated by human hands. The
stabilizer may not be effective depending slightly on
the amount of oscillation.
Select the iris (F number) from among the following:
F1.6, F2, F2.4, F2.8, F3.4, F4.0, F4.8, F5.6, F5.8, F8.0,
F9.6, F11, F14, F16, F19, F22, F28, Close.
Gain
Select the gain (dB) from among the following:
-3 dB, 0 dB, 2 dB, 4 dB, 6 dB, 8 dB, 10 dB, 12 dB, 14
dB, 16 dB, 18 dB, 20 dB, 22 dB, 24 dB, 26 dB, 28 dB
• The view angle differs depending on the Stabilizer On/
Off setting.
Note
Camera reset
When the shutter speed is set to 1 sec or 1/2 sec in the
Shutter priority or Manual mode, set the Focus mode
menu and the White balance mode menu to Manual.
Click Apply, and “Camera reset OK?” appears. Click
OK on the dialog to reset the camera settings on the
Camera setting page to the factory settings.
Day/Night mode
Exposure compensation
Select the Day/Night mode that selects the IR (infrared)
cut filter operation mode from among Disable, Auto,
Manual and Timer.
After selecting the mode, click OK to update the camera
to the selected mode.
When the Exposure mode menu is set to Full auto,
Shutter priority or Iris priority, select On to activate
the exposure compensation, or Off to deactivate it.
When it is set to On, select the EV value from among the
following:
+1.75, +1.5, +1.25, +1, +0.75, +0.5, +0.25, 0, –0.25, –
0.5, –0.75, –1, –1.25, –1.5, –1.75 (EV)
Disable: The Day mode is always set.
Auto: The Day/Night mode is set automatically. It is
normally set in the Day mode and changes to the
Night mode in a dark place.
Saturation
Select the saturation in 7 steps, from –3 to 3.
Selecting 3 gives the image with the highest saturation.
Manual: Set the Day/Night mode manually.
Note
If you select Manual, On and Off appear. Select On
to set to the Night mode, and Off to the Day mode.
The Saturation setting is effective for the computer
image only. (It is not effective for the video signal
output.)
Timer: Set the Day/Night mode using the timer.
If you select Timer, the Schedule No. menu appears
at the bottom. Select the schedule so that the Day/
Night mode is normally set to the Day mode, and it
enters the Night mode at the start time of the
Sharpness
Select the sharpness in 16 steps, from 1 to 16.
Selecting 16 gives the image with the highest sharpness.
schedule and returns to the Day mode at the end time.
Contrast
Select the contrast in 7 steps, from –3 to 3.
Selecting 3 gives the image with the highest contrast.
Schedule No.
When the Day/Night mode menu is set to Timer, click
the check box of the desired schedule No.1 to 6 to
activate the Day/Night mode.
21
Setting the Camera — Camera setting Page
Download from Www.Somanuals.com. All Manuals Search And Download.
To check the contents of the schedule, click Schedule
Configuring the Network
— Network (Ethernet) setting
Page
OK/Cancel
When you click Network on the Administrator menu,
the Network (Ethernet) setting page appears.
Use this page to configure the network to connect the
camera and the computer through the Ethernet.
DHCP
Select On to assign the IP address to the camera
automatically. When you have assigned a proper IP
address to the camera, select Off.
Note
When you set DHCP to On, make sure that there is an
DHCP server on the network.
DNS auto acquisition
When DHCP is set to On, select if the IP address of the
DNS server is assigned automatically or not. Select On
to assign the IP address of the DNS server automatically.
IP address
Type the IP address of the camera.
Subnet mask
Type the subnet mask.
Default gateway
Type the default gateway.
MAC address
Displays the MAC address of the camera.
Primary DNS
Type the IP address of the primary DNS server.
22
Configuring the Network — Network (Ethernet) setting Page
Download from Www.Somanuals.com. All Manuals Search And Download.
Secondary DNS
Type the IP address of the secondary DNS server, if
necessary.
Setting the User
— User setting Page
Bandwidth control
Limits the bandwidth of the data communication of the
camera.
You can select from among the following:
Unlimited, 0.5, 0.6, 0.7, 0.8, 0.9, 1.0, 2.0, 3.0, 4.0, 5.0,
6.0, 7.0, 8.0 (Mbps)
When you click User on the Administrator menu, the
User setting page appears.
Use this page to set the user names and passwords of
Administrator and up to 9 kinds of users (User 1 to User
9), and the access right of each user.
Select Unlimited when you do not want to limit the
bandwidth.
Notes
• If you limit the bandwidth, the camera performance
may be affected, for example, the frame rate of image
display may be reduced.
• The actual bandwidth may differ from the selected
option depending on the network environments.
OK/Cancel
Administrator, User 1 to 9
Specify User name, Password, Re-type password and
Access right for each user ID.
User name
Type a user name between 4 and 16 characters.
Password
Type a password between 4 and 16 characters.
Re-type password
To confirm the password, type the same characters as
you typed in the Password box.
Note
If you type an incorrect character in the User name,
Password or Re-type password box, a message like the
following appears. In this case, click OK to cancel the
message and re-type the correct character.
Access right
Select the access right for each user from the drop-down
list. You can select from Level 1 to Level 4. The rights
afforded to each access right are as follows:
23
Setting the User — User setting Page
Download from Www.Somanuals.com. All Manuals Search And Download.
Level 1: Allows monitoring of the camera image
(including some operations for monitoring)
Setting the Security
— Security setting Page
Level 2: Allows monitoring of the camera image and
camera operations.
When you click Security on the Administrator menu,
the Security setting page appears.
Use this page to limit the computers that can access the
camera.
Level 3: Allows monitoring of the camera image,
camera operations and manual application
operations.
Level 4: Allows all the access right as Administrator.
Activating/Deactivating the
Security Function
No access right: Use this option when you want to
prohibit access to the camera temporarily.
— Security usage setting Page
User access right
Select the level of the access right to require user
authentication.
The authentication dialog will appear where user
authentication is required.
To activate the security function, select Use security
function, then click OK. The Security setting page
appears.
If you do not use the security function, select Do not use
security function, then click OK.
Level 1: Performs user authentication when a user
accesses the following pages: main viewer page
Setting the Security Function
—Securing setting Page
Level 2: Performs user authentication when a user
accesses the following pages: Camera control parts,
Trigger control parts or Administrator menu page.
No user authentication is required to display the
main viewer page.
Level 3: Performs user authentication when a user
accesses the following pages: Trigger control parts
or Administrator menu page.
No user authentication is required to display the
main viewer page or the Camera control parts.
Level 4: Performs user authentication when a user
accesses the Administrator menu page only.
No user authentication is required to display the
other pages.
Default policy
Select the basic policy of the limit from Allow and
Deny.
If you select Allow, you will basically allow access to
the camera and only deny access from the computers
specified on the Network address/Subnet 1 to Network
address/Subnet 10 menus below.
OK/Cancel
If you select Deny, you will basically deny access to the
camera, and only allow access from the computers
specified on the Network address/Subnet 1 to Network
address/Subnet 10 menus.
24
Setting the Security — Security setting Page
Download from Www.Somanuals.com. All Manuals Search And Download.
Network address/Subnet 1 to Network
address/Subnet 10
Type the IP addresses and subnet mask values you want
to allow or deny access to the camera.
You can specify up to 10 IP addresses and subnet mask
values. For a subnet mask, type 8 to 32.
To temporarily cancel the Default Policy for a specified
IP address/subnet mask, select Allow or Deny from the
drop-down list on the right.
Setting the Camera
Position and Action
— Preset position setting Page
When you click Preset position on the Administrator
menu, the Preset position setting page appears.
Use this page to store the pan, tilt and zoom positions of
the camera (Preset position) in memory and program the
sequenced action of the camera (Tour).
Tip
The subnet mask value represents the bit number from
the left of the network address.
For example, the subnet mask value for 255.255.255.0 is
24.
If you set “192.168.0.0/24, Allow,” you can allow access
from the computers having an IP address between
192.169.0.0 and 192.168.0.255.
Storing the Pan, Tilt and Zoom
Positions
— Position preset Section
You can store up to 16 setting of the pan, tilt and zoom
positions (Preset positions) of the camera in memory.
OK/Cancel
Note
For a Preset position setting, you can store the pan, tilt
and zoom positions only. Set the Focus mode, Exposure
Preset No.
Select a preset number 1 to 16 from the drop-down list.
Click Preset call to move the camera to the pan, tilt and
zoom positions stored in the selected preset number.
Preset position name
Type a preset position name for the selected preset
number up to 32 characters.
Apply
Use this button to store the camera position in a preset
number.
To store, proceed as follow:
1
Display the monitor image on the main viewer
page, and pan, tilt and zoom the camera to the
position you want to store as a Preset position.
2
3
Select the Preset No. from the drop-down list and
enter the Preset position name.
Click Apply.
The camera position is stored in memory.
25
Setting the Camera Position and Action — Preset position setting Page
Download from Www.Somanuals.com. All Manuals Search And Download.
Clear
Checking the Preset Position
Settings
Deletes the Preset position data in the selected preset
number.
— Preset position table Section
Moving the Camera to the Preset
Position by the Alarm
— Position at alarm Section
You can move the camera to the preset position by
synchronizing with an external sensor input 1, 2 or 3 or
the activity detection function. If an alarm occurs by the
external sensor input or the activity detection function,
the camera automatically moves to the preset position.
Sensor 1/Sensor 2/Sensor 3
The table shows the preset position name and preset
position setting for each preset number.
Select from the drop-down list the preset number in
which the preset position you want to move the camera
to is stored. The camera moves to the preset position
when an alarm occurs via the corresponding sensor
input.
Programming the Tour
— Tour setting Section
You can program up to 16 preset positions so that the
camera moves to multiple preset positions in sequence
(Tour).
Select None if you do not want to move the camera to
any preset position.
Activity detection
Select from the drop-down list the preset number in
which the preset position you want to move the camera
to is stored. The camera moves to the preset position
when an alarm occurs by the activity detection function.
Click Activity detection to display the Activity
Tour name
Select a tour name from among A, B, C, D and E.
Apply/Cancel
Stay time
Type a period of time for which the camera is to stay at
each preset position, between 1 and 3600 seconds.
Pan speed
Select the pan speed from the drop-down list. You can
select the pan speed from 1 to 19 and Fastest. The
camera pans faster with a higher number setting. With
Fastest, the camera pans at the maximum speed.
26
Setting the Camera Position and Action — Preset position setting Page
Download from Www.Somanuals.com. All Manuals Search And Download.
Tilt speed
Activating the Tour
— Tour selection Section
Select the tilt speed from the drop-down list. You can
select the tilt speed from 1 to 15 and Fastest. The
camera tilts faster with a higher number setting. With
Fastest, the camera tilts at the maximum speed.
You can activate the tour according to the schedule.
Sequence
Select the preset number 1 to 16 for each of 16 list boxes.
The camera moves to the preset positions stored in the
selected preset numbers in sequence. The sequence of
camera movement starts from the preset position
specified in the upper-left list box to the right, then to the
lower list boxes from left to right. After the preset
position specified in the last list box, the camera returns
to the first preset position. This sequence is cyclical.
To determine the end of the program, select end in a list
box. When the camera reaches the preset position
specified in the list box before the end, it returns to the
first preset position, and the sequence recycles.
Selected tour name
Select the tour name A to E you want to activate.
Select None if you do not want to activate any tour or if
you want to stop the tour in action.
Available period
Select the period for which you can activate the tour.
Always: The tour can be activated any time.
Use scheduler: The tour is activated according to the
schedule selected on the Schedule No. menu below.
Apply/Cancel
Schedule No.
When Use scheduler is selected on the Available period
menu, select the schedule you want to activate the tour
(program).
Click to select the check box(es) 1 to 6. You can select
multiple schedules.
Checking the Tour Settings
— Tour table Section
To check the contents of schedules, click Schedule
Notes
• If you operate the camera using the image control
section on the main viewer page, the tour in action
stops.
zooming are not valid.
Sequence
Shows the preset numbers in the programmed order for
each tour A to E.
Speed
Shows the stay time, pan speed and tilt speed settings for
each tour.
27
Setting the Camera Position and Action — Preset position setting Page
Download from Www.Somanuals.com. All Manuals Search And Download.
User name
Type the user name for the FTP server.
Sending Images to FTP
Server
— FTP client setting Page
Password
Type the password for the FTP server.
When you click FTP client on the Administrator menu,
the FTP client setting page appears.
Re-type password
To confirm the password, type the same characters as
you typed in the Password box.
Use this page to set up for capturing and sending still
images to an FTP server. You can capture a still image
at the moment when a trigger occurs by an external
sensor input, the built-in activity detection function or a
manual trigger button, or capture sequenced still images
before and after the trigger. The captured still image(s)
is sent to the FTP server (FTP client function). You can
also send still images periodically.
Remote path
Type the path to the destination up to 64 characters.
Image file name
Type the basic file name you want to assign to the
images when sending to the FTP server. You can use up
to 6 alphanumeric, - (hyphen) and _ (underscore) for
naming.
Activating/Deactivating the FTP
Client Function
— FTP client usage setting Page
Suffix
Select the suffix to add to the file name.
None: No suffix is added. The basic file name is
assigned to the image to be sent to the FTP server.
Date/Time: The date/time suffix is added to the file
name.
To activate the FTP client function, select Use FTP
client function and click OK. The FTP client setting
page appears.
When you do not use the FTP client function, select Do
not use FTP client function and click OK.
The date/time suffix consists of lower two-digits of
year (2 digits), month (2 digits), date (2 digits), hour
(2 digits), minute (2 digits), second (2 digits) and
consecutive number (2 digits), thus 14-digit number
is added to the file name.
Sequence number: A consecutive number is added to
the basic file name. A number of up to 10 digits
between 0000000000 and 4294967295 is added to
the file name.
Note
The frame rate and operability on the main viewer page
may decrease while a file is being transmitted by the
FTP client function.
Tip
When the Mode menu is set to Alarm, the type of alarm
and the capture timing to the alarm are added to the
suffix.
Type of alarm: S1 (Sensor 1), S2 (Sensor 2), S3 (Sensor
3), AD (Activity Detection)
Setting the FTP Client Function
— FTP client setting Page
Capture timing: PR (Pre-alarm), JT (Just alarm), PT
(Post-alarm)
Sequence No. clear
Click Apply to reset the Sequence number suffix to 0.
Mode
Select the mode of the FTP client function.
FTP server name
Type the FTP server name to upload still images up to 64
characters, or the IP address of the FTP server.
Manual: Sends still images to the FTP server manually.
After selecting Manual, click OK. The FTP client
function mode is set to Manual.
28
Sending Images to FTP Server — FTP client setting Page
Download from Www.Somanuals.com. All Manuals Search And Download.
In this mode, when you click the
button on the main viewer page, a still image is
captured and sent to the FTP server. (See
(Trigger)
Available period
Select the period for which the selected alarm mode is
available.
Always: The selected alarm mode is available any time.
Use scheduler: The selected alarm mode is available
according to the schedule selected in Schedule No.
below.
Alarm: Sends still images to the FTP server by
synchronizing with an external sensor input or the
built-in activity detection function. When you select
Alarm, the Alarm mode setting section appears (see
Schedule No.
When Use scheduler is selected on the Available period
menu, select the schedule you want the selected alarm
mode being available.
Click to select the check box(es) 1 to 6. You can select
multiple schedules.
To check the contents of schedules, click Schedule
Note
If the Suffix menu is set to None, you cannot select
the Alarm mode. When you want to use the Alarm
mode, set the Suffix menu to Date/Time or
Sequence number.
Periodical sending: Sends still images to the FTP
server periodically. When you select Periodical
sending, the Periodical sending mode setting section
Alarm buffer configuration
Click Alarm buffer to display the Alarm buffer setting
page.
For details, see “Setting the Alarm Buffer — Alarm
Back/OK
Note
If an alarm occurs during the Alarm buffer processing,
that alarm is ignored.
Alarm mode setting Section
Digest viewer
If you select On, an HTML file (.html) and a Java Script
file (.js) are added each time the selected alarm is
detected.
When you open the added HTML file using a general
browser, the digest viewer runs and you can view the
still pictures in the alarm buffer in sequence (quasi-
animation).
Alarm
Select the alarm to link the FTP client function. If the
selected alarm is detected, the still images before and
after the alarm are captured sequentially and sent to the
FTP server.
Periodical sending mode setting
Section
Sensor 1: External sensor connected to sensor input 1 of
the camera I/O port
Sensor 2: External sensor connected to sensor input 2 of
the camera I/O port
Sensor 3: External sensor connected to sensor input 3 of
the camera I/O port
Activity detection: The activity detection function built
in the camera
Interval time
Type the interval at which you want to send images to
the FTP server periodically. You can set the hour (H),
minutes (M) and seconds (S) between 1 second and 24
hours (one day).
To set the activity detection function, click Activity
detection. The Activity detection setting page
29
Sending Images to FTP Server — FTP client setting Page
Download from Www.Somanuals.com. All Manuals Search And Download.
When you select Auto, the image is displayed in the size
specified with the Image size menu on the Camera
Available period
Select the period for which the periodical sending mode
is available.
Always: The periodical sending mode is available any
time.
Play speed
Use scheduler: The periodical sending mode is
available according to the schedule selected in
Schedule No. below.
Select the play speed from 1 to 5. 5 is the highest speed.
Note
Whether you can play the image at a high speed depends
on the performance of your computer. You may need to
select a lower speed.
Schedule No.
When Use scheduler is selected on the Available period
menu, select the schedule you want the perdiodical
sending mode being available.
Click to select the check box(es) 1 to 6. You can select
multiple schedules.
To check the contents of schedules, click Schedule
Play
Click this button to start playing. Playing stops when the
last still image is displayed.
Next
When a still image is displayed, click this button to
display the next numbered still image.
Operating the Digest Viewer
Prev (previous)
When a still image is displayed, click this button to
display the previous numbered still image.
If you download the HTML file, the Java Script file and
the JPEG image files to your computer and open HTML
file using a general browser, the digest viewer is
displayed on the screen.
Still
Digest viewer
Click this button to stop playing temporarily.
Stop
Click to stop playing. The still image of number 1 is
displayed.
Number
Displays the consecutive still image number.
Date
Displays the date and time when the image is captured.
Image view size
Select the image size to be displayed on the digest
viewer from among the following: Auto, 160 × 120, 320
× 240, 640 × 480
30
Sending Images to FTP Server — FTP client setting Page
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting the FTP Server Function
— FTP server setting Page
You can register up to 10 user names and passwords to
allow logging in the camera using the FTP client
software of the computer.
Downloading Images
from the Camera
— FTP server setting Page
When you click FTP server on the Administrator menu,
the FTP server setting page appears.
Use this page to set up for the FTP server function which
finds a specified still image file stored in the built-in
memory of the camera (about 8 MB) or the ATA
memory card inserted into the PC card slot, or download
the still image file from the card.
Activating/Deactivating the FTP
Server Function
— FTP server usage setting Page
Built-in memory
Displays the free space of the built-in memory of the
camera.
To activate the FTP server function, select Use FTP
server function and click OK. The FTP server setting
page appears.
When you do not use the FTP server function, select Do
not use FTP server function and click OK.
A-slot (adrv)/B-slot (bdrv)
Displays the type of the PC card inserted into the PC
card slot and its free card space. The PC card slot located
on the lens side is “A-slot,” and that on the camera
bottom side is “B-slot.”
Note
The frame rate and operability on the main viewer page
may decrease when the FTP server function is used.
Selected root directory
Select from the drop-down list, the directory under
which the image file you want to find or download is
stored.
Built-in memory: Built-in memory of the camera
ATA memory card (A-slot): ATA memory card
inserted into A slot of the camera
ATA memory card (B-slot): ATA memory card
inserted into B slot of the camera
User ID
Type a user name between 4 and 16 characters.
Password
Type a password between 4 and 16 characters.
Re-type password
To confirm the password, type the same characters as
you typed in the Password box.
Back/OK
31
Downloading Images from the Camera — FTP server setting Page
Download from Www.Somanuals.com. All Manuals Search And Download.
SMTP server name
Type the SMTP server name up to 64 characters, or the
IP address of the SMTP server.
Sending an Image via E-
mail — SMTP setting Page
Recipient e-mail address
Type the recipient E-mail address up to 64 characters.
You can specify up to three recipient e-mail addresses.
When you click SMTP on the Administrator menu, the
SMTP setting page appears.
Use this page to set up for the SMTP function that can
capture and send a still image attached to an E-mail. You
can capture a still image at the moment when a trigger
occurs by an external sensor input, the built-in activity
detection function or a manual trigger button. The
captured still image is sent as an atttachment of the E-
mail. You can also send a still image periodically.
Administrator e-mail address
Type the Administrator e-mail address up to 64
characters.
This address is used for reply mail and sending error
messages from the camera.
Subject
Activating/Deactivating the SMTP
Function — SMTP usage setting
Page
Type the subject/title of the E-mail up to 64 characters.
Message
Type the text of the E-mail up to 384 characters. (A line
break is equivalent to 2 characters.)
Image file name
Type the basic file name you want to assign to the image
to attach an E-mail. You can use up to 6 alphanumeric,
- (hyphen) and _ (underscore) for naming.
To activate the SMTP function, select Use SMTP
function and click OK. The SMTP setting page
appears.
When you do not use the SMTP function, select Do not
use SMTP function and click OK.
Suffix
Select the suffix to add to the file name.
None: No suffix is added. The basic file name is
assigned to the image to be sent via an E-mail.
Date/Time: The date/time suffix is added to the file
name.
Note
The frame rate and operability on the main viewer page
may decrease while an image file is being transmitted
via an E-mail.
The date/time suffix consists of lower two-digits of
year (2 digits), month (2 digits), date (2 digits), hour
(2 digits), minute (2 digits) and second (2 digits) ,
thus 12-digit number is added to the file name.
Sequence number: A consecutive number is added to
the basic file name. A number of up to 10 digits
between 0000000000 and 4294967295 is added to
the file name.
Setting the SMTP Function
— SMTP setting Page
Sequence No. clear
Click Apply to reset the Sequence number suffix to 0.
Mode
Select the mode of the SMTP function.
Manual: Sends a still image attached to an E-mail
manually. After selecting Manual, click OK. The
SMTP function mode is set to Manual.
In this mode, when you click the
(Trigger)
button on the main viewer page, a still image is
32
Sending an Image via E-mail — SMTP setting Page
Download from Www.Somanuals.com. All Manuals Search And Download.
Use scheduler: The alarm mode is available according
to the schedule selected on the Schedule No. menu
below.
Alarm: Sends a still image via an E-mail by
synchronizing with an external sensor input or the
built-in activity detection function. When you select
Alarm, the Alarm mode setting section appears (see
Schedule No.
When Use scheduler is selected on the Available period
menu, select the schedule you want the alarm mode
being available.
Click to select the check box(es) 1 to 6. You can select
multiple schedules.
To check the contents of schedules, click Schedule
Periodical sending: Sends a still image via an E-mail
periodically. When you select Periodical sending,
the Periodical sending mode setting section appears
Back/OK
Periodical sending mode setting
Section
Alarm mode setting Section
Interval time
Type the interval at which you want to send an E-mail
with a still image periodically. You can set the hour (H)
and minutes (M) between 30 minutes and 24 hours (one
day).
Alarm
Available period
Select the period for which the periodical sending mode
is available.
Always: The periodical sending mode is available any
time.
Use scheduler: The periodical sending mode is
available according to the schedule selected on the
Schedule No. menu below.
Select the alarm to link the SMTP function. If the
selected alarm is detected, a still image is captured and
sent via an E-mail.
Sensor 1: External sensor connected to sensor input 1 of
the camera I/O port
Sensor 2: External sensor connected to sensor input 2 of
the camera I/O port
Sensor 3: External sensor connected to sensor input 3 of
the camera I/O port
Activity detection: The activity detection function built
in the camera.
To set the activity detection function, click Activity
detection. The Activity detection setting page appears
Schedule No.
When Use scheduler is selected on the Available period
menu, select the schedule you want the perdiodical
sending mode being available.
Click to select the check box(es) 1 to 6. You can select
multiple schedules.
To check the contents of schedules, click Schedule
Note
The image that can be attached to an E-mail is the one
captured at the moment when an alarm is input. If the
next alarm occurs while the captured image is being
processed, that alarm is ignored.
Available period
Select the period for which the alarm mode is available.
Always: The alarm mode is available any time.
33
Sending an Image via E-mail — SMTP setting Page
Download from Www.Somanuals.com. All Manuals Search And Download.
appears. Click the button, and the Camera setting
page appears and you can set the Day/Night function
In the Night mode, the relay corresponding to the
alarm out 1 is short-circuited. In the Day mode, it is
open.
Setting the Alarm Out 1
or 2
— Alarm out 1 or 2 setting Page
When you click Alarm out 1 on the Administrator
menu, the Alarm out 1 setting page appears. When you
click Alarm out 2 on the Administrator menu, the
Alarm out 2 setting page appears.
Alarm: Controls alarm out 1 by synchronizing with an
external sensor input or the built-in activity detection
function. When you select Alarm, the Alarm mode
Use these pages to set up for the Alarm out function that
controls the alarm out 1 or alarm out 2 of the I/O port
located on the rear the camera. You can control the
alarm out when a trigger occurs by an external sensor
input, the built-in activity detection function, a manual
trigger button, the Day/Night function or the timer.
The setting items for alarm out 1 and alarm out 2 are the
same. This section explains how to set alarm out 1 as an
example.
Timer: Controls alarm out 1 by the timer. When you
select Timer, the Timer mode setting section appears
Alarm mode setting Section
Activating/Deactivating the Alarm
Out 1 Function
— Alarm out 1 usage setting Page
Alarm
Select the alarm to link the alarm out 1 function. If the
selected alarm is detected, the alarm out 1 status
changes.
Sensor 1: External sensor connected to sensor input 1 of
the camera I/O port
Sensor 2: External sensor connected to sensor input 2 of
the camera I/O port
Sensor 3: External sensor connected to sensor input 3 of
the camera I/O port
To activate the Alarm out 1 function, select Use alarm
out 1 function and click OK. The Alarm out 1 setting
page appears.
When you do not use the Alarm out 1 function, select Do
not use alarm out 1 function and click OK.
Activity detection: The activity detection function built
in the camera.
Setting the Alarm Out 1 Function
— Alarm out 1 setting Page
To set the activity detection function, click Activity
detection. The Activity detection setting page
Available period
Select the period for which the alarm mode is available.
Always: The alarm mode is available any time.
Use scheduler: The alarm mode is available according
to the schedule selected on the Schedule No. menu
below.
Mode
Select the mode of the Alarm out 1 function.
Manual: Controls the alarm out 1 manually.
In this mode, you can short-circuit and open the
alarm out 1 by clicking the
(Trigger) button on
Schedule No.
When Use scheduler is selected on the Available period
menu, select the schedule you want the alarm mode
being available.
Click to select the check box(es) 1 to 6. You can select
multiple schedules.
Day/Night: Controls alarm out 1 by synchronizing with
the Day/Night function of the camera. When you
select Day/Night, the Day/Night setting button
34
Setting the Alarm Out 1 or 2 — Alarm out 1 or 2 setting Page
Download from Www.Somanuals.com. All Manuals Search And Download.
To check the contents of schedules, click Schedule
Recording Images in
Memory
— Image memory setting Page
Alarm duration
Select the duration for which the alarm output is short-
circuited between 1 and 60 sec.
When you click Image memory on the Administrator
menu, the Image memory setting page appears.
Use this page to set up for the image memory function
which captures a still image and records it in the built-in
memory of the camera (about 8 MB) or the ATA
memory card. You can capture a still image at the
moment when a trigger occurs by an external sensor
input, the built-in activity detection function or a manual
trigger button. The captured still image is recorded in
the built-in memory or the ATA memory card. You can
also record a still image periodically.
Timer mode setting Section
Schedule No.
Select the schedule you want to activate the alarm out 1
timer mode.
The recorded image file can be found or downloaded to
the computer using the FTP server function. (See
Click to select the check box(es) 1 to 6. You can select
multiple schedules.
The alarm out 1 is short-circuited at the start time of the
selected schedule, and it switches to open at the end
time.
To check the contents of schedules, click Schedule
Activating/Deactivating the Image
Memory Function — Image memory
usage setting Page
Built-in memory
Displays the free space of the built-in memory of the
camera.
A-slot/B-slot
Displays the type of the PC card inserted into the PC
card slot and its free card space. The PC card slot located
on the lens side is “A-slot,” and that on the camera
bottom side is “B-slot.”
Use image memory function/Do not use
image memory function
To activate the Image memory function, select Use
image memory function and click OK. The Image
memory setting page appears.
When you do not use the Image memory function, select
Do not use image memory function and click OK.
35
Recording Images in Memory — Image memory setting Page
Download from Www.Somanuals.com. All Manuals Search And Download.
Type of alarm: S1 (Sensor 1), S2 (Sensor 2), S3 (Sensor
3), AD (Activity Detection)
Capture timing: PR (Pre-alarm), JT (Just alarm), PT
(Post-alarm)
Memory
Select the memory you want to store the image to, from
the drop-down list.
Built-in memory: Built-in memory of the camera
(about 8 MB)
ATA memory card (A-slot): ATA memory card
inserted into A slot of the camera
ATA memory card (B-slot): ATA memory card
inserted into B slot of the camera
Sequence No. clear
Click Apply to reset the Sequence number suffix to 0.
Overwrite
Select if you overwrite the file or not when there is
insufficient memory space to record the image.
Select On to allow overwriting. The oldest file or folder
is overwritten first.
Select Off to prohibit overwriting. In this case, a new
file cannot be stored.
Notes
• The image recorded in the built-in memory will be
erased when the power of the camera is turned off.
• The frame rate and operability on the main viewer
page may decrease during image storage.
Mode
Recording an Image in the Selected
Memory — Image memory setting
Page
Select the mode of the Image memory function.
Manual: Records a still image in the selected memory
manually.
In this mode, when you click the
(Trigger) button
on the main viewer page, a still image is captured and
Alarm: Records a still image in the selected memory by
synchronizing with an external sensor input or the
built-in activity detection function. When you select
Alarm, the Alarm mode setting section appears (see
Image file name
Type the basic file name you want to assign to the
images when saving in the memory. You can use up to
6 alphanumeric, - (hyphen) and _ (underscore) for
naming.
Note
If the Suffix menu is set to None, you cannot select
the Alarm mode. When you want to use the Alarm
mode, set the Suffix menu to Date/Time or
Sequence number.
Suffix
Select the suffix to add to the file name.
None: No suffix is added. The basic file name is
assigned to the image to be recorded in memory.
Date/Time: The date/time suffix is added to the file
name.
Periodical recording:Records still images in the
selected memory periodically. When you select
Periodical recording, the Periodical recording
mode setting section appears (see page 37).
The date/timer suffix consists of lower two-digits of
year (2 digits), month (2 digits), date (2 digits), hour
(2 digits), minute (2 digits), second (2 digits) and
consecutive number (2 digits), thus 14-digit number
is added to the file name.
Alarm mode setting Section
Sequence number: A consecutive number is added to
the basic file name. A number of up to 10 digits
between 0000000000 and 4294967295 is added to
the file name.
Tip
When the Mode menu is set to Alarm, the type of alarm
and the capture timing to the alarm are added to the
suffix.
36
Recording Images in Memory — Image memory setting Page
Download from Www.Somanuals.com. All Manuals Search And Download.
Alarm
Periodical recording mode setting
Section
Select the alarm to link the Image memory function. If
the selected alarm is detected, a still image is captured
and recorded in the selected memory.
Sensor 1: External sensor connected to sensor input 1 of
the camera I/O port
Sensor 2: External sensor connected to sensor input 2 of
the camera I/O port
Sensor 3: External sensor connected to sensor input 3 of
the camera I/O port
Activity detection: The activity detection function built
in the camera.
Interval time
Type the interval at which you want to record an image
periodically. You can set the hour (H), minutes (M) and
seconds (S) between 1 second and 24 hours (one day).
To set the activity detection function, click Activity
detection. The Activity detection setting page
Available period
Select the period for which the periodical recording
mode is available.
Always: The periodical recording mode is available any
time.
Use scheduler: The periodical recording mode is
available according to the schedule selected in the
Schedule No. menu below.
Available period
Select the period for which the alarm mode is available.
Always: The alarm mode is available any time.
Use scheduler: The alarm mode is available according
to the schedule selected in the Schedule No. menu
below.
Schedule No.
When Use scheduler is selected on the Available period
menu, select the schedule you want the alarm mode
being available.
Click to select the check box(es) 1 to 6. You can select
multiple schedules.
To check the contents of schedules, click Schedule
Schedule No.
When Use scheduler is selected on the Available period
menu, select the schedule you want the periodical
recording mode being available.
Click to select the check box(es) 1 to 6. You can select
multiple schedules.
To check the contents of schedules, click Schedule
Alarm buffer configuration
Click Alarm buffer to display the Alarm buffer setting
page.
For details, see “Setting the Alarm Buffer — Alarm
Digest viewer
If you select On, an HTML file (.html) and a Java Script
file (.js) are added every 100 files.
When you open the added HTML file using a general
browser, the digest viewer runs and you can view the
still pictures in the alarm buffer in sequence (quasi-
animation).
Note
If an alarm occurs during the Alarm buffer processing,
that alarm is ignored.
Note
Digest viewer
If you select On, an HTML file (.html) and a Java Script
file (.js) are added each time the selected alarm is
detected.
If the Suffix menu is set to None, you cannot select On.
When you want to use the digest viewer, set the Suffix
menu to Date/Time or Sequence number.
When you open the added HTML file using a general
browser, the digest viewer runs and you can view the
still pictures in the alarm buffer in sequence (quasi-
animation).
Back/OK
37
Recording Images in Memory — Image memory setting Page
Download from Www.Somanuals.com. All Manuals Search And Download.
Directory Structure of Image
Memory
The images are recorded in the memory with the
following directory structure.
Setting the Alarm Buffer
— Alarm buffer setting Page
When you click Alarm buffer on the Administrator
menu, the Alarm buffer Setting page appears.
Use this page to set up for the alarm buffer used in the
ATA memory card (A-slot): Slot A
ATA memory card (B-slot): Slot B
Built-in memory: Drive C
Each slot or drive has the following directory structure.
Drive root
Date
Alarm
Sensor 1
xxxxxxx.jpg
aaaaaa.html
aaaaaa.js
Sensor 2
Sensor 3
ActDet
yyyyyyy.jpg
bbbbbb.html
bbbbbb.js
Recording interval
Select the interval (in seconds) at which you want to
record an image in the alarm buffer.
You can select from among the following intervals:
SNC-RZ30N:
1/30, 1/15, 1/10, 1/5, 1/2, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
(seconds)
SNC-RZ30P:
1/25, 1/12, 1/8, 1/5, 1/2, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
(seconds)
Timer
Manual
zzzzzzz.jpg
cccccc.html
cccccc.js
Pre-alarm images
Type the number of images to be recorded before
detecting an alarm (Pre-alarm).
ddddddd.jpg
eeeeeee.jpg
ffffffff.jpg
Post-alarm images
Type the number of images to be recorded after
detecting an alarm (Post-alarm).
A
represents a folder created automatically. The
Date folder has a 6-digit folder name consisting of the
lower two digits of year (2 digits), month (2 digits) and
date (2 digits) . The Sensor 1, Sensor 2, Sensor 3 and
Act Det (activity detection) folders correspond to alarm
modes. The Timer folder corresponds to the periodical
recording mode. And, the Manual folder corresponds to
the manual mode.
Maximum alarm images
Displays the maximum number of images that can be
recorded in the alarm buffer with the current image size
and image quality.
JPEG image files are stored in each folder. If the digest
viewer is allowed, an HTML file (.html) and a Java
Script file (.js) are created automatically at the time of
each alarm event. For the periodical recording mode, an
HTML file (.html) and a Java Script file (.js) are created
automatically every 100 JPEG image files.
Note
The number of Maximum alarm images differs
depending on the Image size and Image quality settings
on the Camera setting page.
Check the Maximum alarm images setting and set so
that the total number of Pre-alarm images and Post-
alarm images does not exceed the Maximum alarm
images.
If you set both Pre-alarm images and Post-alarm images
to 0, only one image is recorded at the moment when an
alarm is detected.
OK/Cancel
38
Setting the Alarm Buffer — Alarm buffer setting Page
Download from Www.Somanuals.com. All Manuals Search And Download.
TCP port No.
When you select TCP on the Transparency type menu,
type the port number for the TCP port (TCP Generic
Driver). Set a port number other than Well-Known port
numbers (0 to 1023).
Communicating Data via
Serial Port
— Serial setting Page
Baud rate
When you click Serial on the Administrator menu, the
Serial setting page appears.
Select the communication baud rate for the peripheral
device connected to the serial interface. You can select
from among the following baud rates:
Use this page to set up for the date communication via
the serial interface. You can input data from a computer
via the network to the camera, and output it to an
external serial interface for controlling a peripheral
device, or, vice versa, input data from a peripheral
device to the camera via the external serial interface and
output it to the computer via the network.
38400, 19200, 9600, 4800, 2400, 1200, 600, 300 (bps)
Parity bit
Select the parity bit for the peripheral device connected
to the serial interface: None, Odd or Even.
Perform the setting to match the peripheral device you
connect to the camera.
Character length
Select the character length for the peripheral device
connected to the serial interface: 7 or 8 (bits).
Stop bits
Select the stop bit for the peripheral device connected to
the serial interface: 1 or 2 (bits).
OK/Cancel
Standard
Select the serial standard used to connect a peripheral
device via the serial interface: RS232C or RS485.
Note
If RS485 is selected on the Standard menu, the data
communication is semi-duplex. Connect a peripheral
device supporting semi-duplex communication.
Transparency type
Select the port through which you send and receive data
via the network: HTTP (HTTP Generic Driver) or TCP
(TCP Generic Driver).
HTTP: When you select HTTP, you can realize data
communication by creating an HTML program with
CGI commands embedded in the computer.
For the CGI commands, consult your authorized
Sony dealer.
TCP: When you select TCP, specify the TCP port
number on the TCP Port No. menu, and you can send
and receive data that is input to or output from the
external serial communication port. You can check
the connection to the camera using a DOS command
“telnet [host name] [assigned port number]”.
39
Communicating Data via Serial Port — Serial setting Page
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting the Schedule
Setting the Activity
Detection Function —
Activity detection setting Page
— Schedule setting Page
When you click Schedule on the Administrator menu,
the Schedule setting page appears.
When you click Activity detection on the Administrator
menu, the Activity detection setting page appears.
Use this page to set up for the activity detection to link
various applications.
Use this page to set up to six schedules used for the
preset position function, Day/Night function, FTP client
function, SMTP function, Alarm out 1 or 2 function and
Image memory function.
Schedule No. 1 to Schedule No. 6
For each schedule, specify Start time (hour and minutes)
and End time (hour and minutes), and check the days of
the week that you want to activate the function.
Sensitivity
Select the sensitivity of the activity detection from the
drop-down list. You can select the sensitivity between
Level 1 and Level 9. Level 9 is the maximum
sensitivity.
OK/Cancel
Tip
The Sensitivity of the activity detection means a
proportion of the changed area (pixels) to the whole
activity detection area.
OK/Cancel
Setting the Activity Detection Area
Set the activity detection working area as follows:
1
2
Determine the view angle of the camera at which
you want to perform activity detection, using the
pan, tilt and zoom.
Click Activity detection on the Administrator
menu.
A still picture is captured and the Activity detection
setting page appears.
40
Setting the Schedule — Schedule setting Page / Setting the Activity Detection Function — Activity detection setting Page
Download from Www.Somanuals.com. All Manuals Search And Download.
3
Hold down the mouse left button and drag it
diagonally.
The portion marked with a red frame determines the
activity detection working area.
As the default setting, the whole area is set as the
activity detection working area.
Showing the Pop-up
— Pop-up setting Page
When you click Pop-up on the Administrator menu, the
Pop-up setting page appears.
Use this page to set up for displaying a pop-up with your
favorite message on the computer screen. You can
display the pop-up on all the computers monitoring the
camera image by the Administrator's manual operation.
The pop-up can also be displayed on the computer
logged in as the Administrator when there is an alarm
input.
Manual pop-up text
Type the text to be displayed on a pop-up between 1 and
64 characters.
Click Apply to display the pop-up on all the computers
monitoring the camera.
Alarm pop-up text
Sensor 1/Sensor 2/Sensor 3/Activity detection
Set a pop-up to be displayed when an alarm is input.
This pop-up is only displayed on the computer
monitoring the camera as the Administrator.
Select On to show a pop-up when an alarm occurs by the
corresponding sensor. Select Off not to show it.
On each text box, type the text to be displayed on the
pop-up between 1 and 64 characters.
OK/Cancel
41
Showing the Pop-up — Pop-up setting Page
Download from Www.Somanuals.com. All Manuals Search And Download.
The program detects the SNC-RZ30 cameras
connected to the local network and lists them on the
Network tab window.
Others
Using the Supplied
Setup Program
To connect the camera to a network, you need to assign
a new IP address to the camera when you installed the
camera for the first time.
You can assign an IP address in two ways:
• Using the setup program stored in the supplied CD-
ROM (see page 42)
• Using the ARP (Address Resolution Protocol)
This section explains how to assign an IP address to the
camera using the supplied setup program and configure
the network.
The setup program also allows the communication
bandwidth setting and date and time setting.
Before starting, connect the camera to a computer or a
local network, referring to “Assigning the IP Address to
the Camera” in the supplied Installation Manual.
Assigning the IP Address Using the
Setup Program
6
7
Click on the camera you want to assign a new IP
address in the list.
The network settings for the selected camera are
displayed.
1
2
Insert the supplied CD-ROM disc into your CD-
ROM drive.
Set the IP address.
Double-click the Setup folder in the CD-ROM
drive.
To obtain the IP address automatically from a
DHCP server:
Select Obtain an IP address automatically.
The IP address, Subnet mask and Default gateway
are assigned automatically.
3
4
Double-click Setup.exe.
Install the IP Setup Program to your computer
following the wizard displayed.
To specify the IP address manually:
Select Use the following IP address, and type the
IP address, Subnet mask and Default gateway in
each box.
If the Software License Agreement is displayed,
read it carefully and accept the agreement to
continue the installation.
5
Start the IP Setup Program.
8
Set the primary DNS server address and, if
necessary, secondary DNS server address.
To obtain the DNS server addresses
automatically:
Select Obtain DNS server address automatically.
42
Using the Supplied Setup Program
Download from Www.Somanuals.com. All Manuals Search And Download.
To specify the DNS server addresses manually:
Select Use the following DNS server address, and
type the Primary DNS server address and
3
4
Type the Administrator name and Administrator
password in each box.
Secondary DNS server address in each box.
Click OK.
If "Setting OK" is displayed, the bandwidth setting
is completed.
Note
The Third DNS server address and Fourth DNS
server address are invalid for this camera.
Setting the Date and Time
You can set the date and time on the camera.
9
Type the Administrator name and Administrator
password.
1
Click the Date time tab to display the date/time
setting window.
The default settings of both items are “admin.”
10 Confirm that all items are correctly set, then click
OK.
If “Setting OK” is displayed, the IP address is
correctly assigned.
Changing the Communication
Bandwidth
1
Click the Bandwidth control tab to display the
bandwidth setting window.
The current bandwidth is displayed in Current
bandwidth.
2
Click to select the camera you want to set the date
and time for.
You can select multiple cameras and set the date
and time simultaneously.
3
4
5
Select the date/time format from the Date time
format drop-down list.
Select the area where the camera is installed from
the Time zone selecting drop-down list.
Set the date and time.
You can set the date and time in two ways.
2
Click to select the desired bandwidth from the
Setting bandwidth list box.
Manual setting
Set the current date and time on the Manual current
date time setting boxes, and click OK. The setting
43
Using the Supplied Setup Program
Download from Www.Somanuals.com. All Manuals Search And Download.
boxes are for the year (lower two digits), month,
date, hour, minutes and seconds from left to right.
Assigning the IP
Using the computer’s date and time
The date and time set on the computer is displayed
in the PC current date time setting box.
Click OK on the right to set the camera’s date and
time to the displayed computer's date and time.
Address to the Camera
Using ARP Commands
This section explains how to assign an IP address to the
camera using ARP (Address Resolution Protocol)
commands without using the supplied setup program.
Note
Due to the network properties, there may be a slight
difference between the displayed computer's date and
time and those set on the camera.
Note
Enter the ARP commands within 5 minutes after the
power of the camera is turned on.
Rebooting the Camera
Click Reboot on the Network tab to reboot the camera.
1
2
Open the DOS window on the computer.
Enter the IP address and the MAC address of the
camera you want assign a new IP address to, using
the following ARP commands.
It will take about 10 to 20 seconds to reboot.
apr -s <Camera's IP address> <Camera's MAC address>
ping -t <Camera's IP address>
Example:
apr -s 192.168.0.100 08-00-46-21-00-00
ping -t 192.168.0.100
3
When the following line is displayed on the DOS
window, hold down Ctrl and press C.
Reply from 192.168.0.100:bytes=32 time...
You will normally receive the reply after about 5
repetitions of "Request time out."
Note
If you do not receive the reply, check the following:
– Did you enter the ARP commands within 5 minutes
after the camera was turned on?
If not, turn off the camera and restart the operation.
– Is the NETWORK indicator on the camera flashing?
If the indicator goes off, the network connection has a
problem. Connect the network correctly.
– Did you enter the IP address previously used for
another device?
Assign a new IP address to the camera.
– Do the computer and the camera have the same
network address?
If not, set the same network address on the computer
and the camera.
Sony Corporation
Download from Www.Somanuals.com. All Manuals Search And Download.
|