PACKAGE CONTENTS & SPECIFICATIONS
What’s in the Box:
Portable Air Conditioner
Exhaust Hoses (1)
Hose Adapters (1)
Window Kit Adapter (1)
Remote Control
AAA Batteries (2)
Window Kit - 3 Sliding Panels (1 single hose panel, 2 extension panels)
Owner’s Manual
SPECIFICATIONS
•
•
•
•
•
The cooling capacity is measured at an ambient temperature of DB 86 °F, WB 78 °F.
Noise level is measured at a distance of 3.28 ft away from the front of the unit, when the unit is in cooling mode.
Power consumption is measured when the fan runs at the highest speed setting.
These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit.
If the environment temperature is higher than the max operating temperature or lower than the minimum operating temperature,
the air conditioner may not work properly.
MODEL
PE7-10R-03
10,000 BTU/Hr
1060 Watts
Cooling Capacity
Cooling Power Consumption
Dehumidifying Capacity (Pints per day)
48 Pints/Day
Air Flow Volume (CFM)
Power Source
265 CFM
115 V / 60 HZ
9.3 Amps
45 dB (A)
56.2 lbs
Rated Current
Sound Pressure Level
Product Weight
Product Dimensions (W x D x H)
Refrigerant
11.75” W x 18.75” D x 24.875” H
R-410A
DISCLAIMER
ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER’S MANUAL ARE THE
PRESENTATION OF THE MANUFACTURER. SOLEUS INTERNATIONAL HAS NOT CONDUCTED INDEPENDENT
TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT DIAGRAM
NOTE: Actual product design may differ slightly from images below.
FRONT
A. Control panel
B. Vertical air louvers
C. Air outlet
D. Horizontal air louvers
E. Casters
F. Power Cord & Plug
BACK
A. Hot air outlet grill
B. Lower air inlet grill
ACCESSORIES
Flexible exhaust hose with 2 adapters
• 3-piece set
• stretches from 14 1/4” to 60 5/8”
(36cm to 150cm)
Adjustable window slider kit
• 3-piece set
• adjusts 19.7” - 55.5” (50cm to 141cm)
Drain tube
4
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
SELECTING THE LOCATION
Place the unit in a flat location where the air out-
lets are not obstructed. Place the unit at least
20” (50cm) away from a wall or other obstacle.
MOUNTING THE EXHAUST HOSE
Slide the square end of the exhaust duct over the
hot air outlet on the back of the unit.
The exhaust hose should be kept as short and
straight as possible. Prevent any sharp bends in
the exhaust hose, as this will trap hot exhaust air.
The hot exhaust air can be vented through the
wall or out a window. If mounting in the wall, the
height of the hole should be 14 1/4” to 60
5/8” (36cm to 150cm).
Soleus Air does not provide a venting kit for
through the wall ventilation. Venting through the
wall requires a custom installation.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
LCDI POWER CORD AND PLUG
This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and
plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord
with no termination on the load side and a LCDI attachment plug on the line side.
The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the
nominal current leakage between the cord shield and either load conductor exceeds a predetermined value.
The cord will remain de-energized until the devise has been manually reset. This is intended to reduce the risk
of a fire in the power cord or combustible materials nearby. The cord shields are not grounded and they must
be considered a shock hazards if exposed. The cord shield must not be connected to ground or to any exposed
metal.
The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test:
1. Plug power cord into wall outlet
2. Press TEST Button, circuit should trip, cutting power to the air conditioner
3. Press RESET button for use
If test button is pressed and unit can still be turned on, current leakage has been detected. Do not use the air
conditioner or attempt to reset the LCDI Plug. Contact Soleus Air Customer Service for troubleshooting
recommendations.
RESET
TEST
WARNING:
1. DO NOT press the TEST button while the air conditioner is operating.
2. The TEST and RESET buttons should not be used as “ON” and “OFF” switches.
3. The cord and plug are not intended to offer protection to externally connected loads or supply circuits.
4. The cord and plug are intended for indoor use only.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
WINDOW KIT INSTALLATION
WINDOW KIT INSTALLATION
The window kit is designed to fit into most standard
vertical and horizontal windows, as well as some
sliding glass doors. However, it may be necessary to
modify some aspects of the installation process for
certain window types.
Open the window or sliding door and adjust the
length of the window kit to fit the opening. If the
window kit is not long enough, connect the extra
window kit panel to fit the opening. Mark and cut
down a single panel of the window kit if neces-
sary.
Window Slider Kit
Minimum: 19.7” (50cm)
Maximum: 55.5” (141cm)
Place the window kit between the window and the
window frame as shown in the images to the right.
Close the window onto the window kit to form a
tight seal.
Attach the exhaust duct adapter to the window kit.
Tabs located on the adapter will lock into place
securing the adapter to the window kit.
Window Slider Kit
Minimum: 19.7” (50cm)
Maximum: 55.5” (141cm)
7
Download from Www.Somanuals.com. All Manuals Search And Download.
WINDOW KIT INSTALLATION
NOTE: The Portable Air Conditioner above may differ from the unit described in this manual. The above directions and images
show general directions for all Soleus Air single hose portable air conditioners.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTROL PANEL & OPERATION
1) Power On and Off - Press the POWER button once to manually turn the unit on. Press the POWER
button once more to turn the unit off.
2) Mode Selection - Press the MODE Button repeatedly to cycle between the different modes:
Air Conditioner and Dehumidifier.
3) Fan Speed Control - Press the FAN Button to cycle through the different fan speeds: High and low.
4) Temperature - Select the desired temperature by pressing either ▼ or ▲ button when using the unit in
cooling mode. The temperature indicator flashes to display the desired temperature setting. After the tem-
perature is set, the unit will display this temperature setting until it is changed by the user. Press the ▼ and
▲ buttons simultaneously on the control panel to change between Celsius or Fahrenheit.
5) Auto-on Timer - To program the Auto-on timer, press the TIMER button when the unit is powered off.
Press the ▲ or ▼ buttons to change the timer to the desired amount of time (1-24 hours) for the unit to
automatically turn on.
6) Auto-off Timer - To program the Auto-off Timer , press the TIMER button when the unit is powered on.
Press the ▲ or ▼ buttons to change the timer to the desired amount of time (1-24 hours) for the unit to
automatically turn on.
7) Swing - To start side-to-side louver oscillation, press the Swing button once. The SWING light will light
up on the control panel. To stop oscillation, press the Swing button again. Vertical air flow direction can be
adjusted manually.
NOTE: HEAT MODE is not available on this model.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
MODE OPERATION
OPERATING THE UNIT USING THE CONTROL PANEL
Air Conditioner Mode
1) Install the exhaust hose and window kit properly (see pages 7 & 8).
2) Plug the Power Cord into an electrical outlet.
3) Turn on the unit by pressing the POWER button on the control panel.
4) Press the ▲ or ▼ buttons until the desired room temperature appears on the control panel
display. The temperature ranges from 61°F - 88 °F (16 °C - 31 °C).
5) Select the desired fan speed by pressing the FAN button.
NOTE: During hot days, the unit will cool the room most efficiently by setting the temperature at the lowest
setting and the fan speed on high. Reducing the length of the exhaust duct, insulating the exhaust hose and
window kit, and keeping direct sunlight to a minimum will also improve the cooling efficiency.
NOTE: When the unit is running on cooling mode, the exhaust hoses are required and must be vented outside
using the supplied window kit.
Dehumidifier Mode
1) Install the exhaust hoses and window kit properly (see pages 7 & 8).
2) Plug the Power Cord into an electrical outlet.
3) Turn on the unit by pressing the POWER Button on the control panel.
NOTE: The unit operates at low fan speed during dehumidifier mode. The unit cools room slightly during
the dehumidification. Keep the windows and doors closed to aid the effectiveness of the unit in removing the
moisture from the room.
NOTE: When the unit is running in dehumidifier mode, the exhaust hoses are required and must be vented
outside using the supplied window kit. The unit will not perform in dehumidifier mode when the room tem-
perature is lower than 61°F .
Compressor Indicator
The compressor light will light up on the control panel display when the compressor turns on. The compressor
light will turn off when the compressor shuts off.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
CONDENSATE EVAPORATION
Emergency Condensate Holding Tank
When the room temperature is low and the indoor humidity is high, the air conditioner may not be able to
evaporate some of the moisture fast enough. When this happens, the water will accumulate in an emergency
condensate tank inside the unit. Once the emergency condensate tank is full, the unit will automatically shut
off and the FULL light will appear on the control panel display. To empty the condensate tank, unscrew the
screw plug at the bottom back of the unit. You will need a small pan, approximately 1” high to catch the water
coming out of the condensate tank. Once the condensate tank is drained, the unit will begin working within a
few minutes. The emergency condensate tank holds approximately 1.5 Liters of water. Another option is to
purchase a small hose from a hardware store that can fit around the 5/8” drain plug on the back of the unit and
drain the unit into a gravity drain or larger pan for continuous drainage.
To resume operation quickly, empty the water container according to the following steps:
1. Turn the unit off. Do not move the unit when the water container is full.
2. Place the drain pan accessory under the drainage port at the back of the unit.
3. Remove the drain plug from the drain hole. The condensate water will drain out automatically. When the
drain pan is full, place the drain plug back onto the drainage hole to stop the water flow. Empty the drain
pan. Repeat until all the water is emptied.
Once the water container has been emptied, place the drain plug back onto the drain hole. Do not
allow the water to drip continuously into the drain pan, as it might easily overflow.
DRAIN PLUG
DRAIN HOLE
11
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATING THE UNIT USING THE REMOTE CONTROL
TIMER/TEMP INCREASE
REMOTE CONTROL
MODE BUTTON
°F/°C
SWING (LOUVER
OSCILLATION)
FAN SPEED
SLEEP MODE
(not available on this
model)
TIMER BUTTON
TIMER/TEMP DECREASE
POWER BUTTON
1) Power On and Off - Press the ON/OFF button on the remote to turn the unit on or off.
2) Mode Selection - Press the MODE Button repeatedly to cycle between the different modes: Air Condi-
tioner and Dehumidifier.
3) Fan Speed - Press the FAN speed button to cycle through low and high fan speeds.
4) Temperature Setting - When the unit is in Air Conditioner mode you can select your desired tempera-
ture. Press the ▲ or ▼ to select your desired temperature setting. The temperature on the multi-color
display on the control panel will increase or decrease accordingly. Pressing the °F/°C button will change
the temperature select between °F and °C.
5) Swing - To turn on oscillation, press the SWING button on the remote control. Once you press SWING,
the louvers on the unit will oscillate side-to-side.
6) Auto-on Timer - To program the Auto-on timer, press the TIMER button when the unit is powered off.
Press the ▲ or ▼ buttons to change the timer to the desired amount of time (1-24 hours) for the unit to
automatically turn on.
7) Auto-off Timer - To program the Auto-off Timer , press the TIMER button when the unit is powered on.
Press the ▲ or ▼ buttons to change the timer to the desired amount of time (1-24 hours) for the unit to
automatically turn on.
8) Sleep Mode - Sleep mode is not available on this model.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
MAINTENANCE
Note: Make sure power is off and the power cord is not plugged into an electrical outlet prior to
performing any maintenance on the unit.
Clean or replace filter - If the air filter is blocked with a dust, the airflow volume may reduce. It is
recommended to clean the filter once every two weeks or as needed.
1) Remove the filter from the filter compartment on the back of the unit.
2) Wash the air filter by immersing it gently into warm water with a neutral detergent. Rinse the filter
and dry it thoroughly out of sunlight.
3) Slide the filter back into the filter compartment after it is thoroughly dried.
4) If the filter is torn or unusable, order a new filter by calling the customer service number on the
warranty page of this manual.
Clean the unit Housing
1) Keep the unit from being exposed directly to the sun to prevent color fading.
2) Clean the surface with a damp cloth and dry it with a soft towel.
Storing the Unit for an Extended Period of Time or Transporting the unit
1) Empty any excess water by unplugging the water drainage stop in the back of the unit (located at
the bottom).
2) Unplug the unit.
3) The unit should be stored in a cool dry place.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY
One Year Limited Warranty
Soleus International Inc. warrants the accompanying Soleus Air Portable Air Conditioner to be free of defects in mate-
rial and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the
date of original retail purchase in the United States.
If the unit exhibits a defect in normal use, Soleus International Inc. will, at its option, either repair or replace it, free of
charge within a reasonable time after the unit is returned during the warranty period.
As a condition to any warranty service obligation, the consumer must present this Warranty Certificate along with a
copy of the original purchase invoice.
THIS WARRANTY DOES NOT COVER:
•
Damage, accidental or otherwise, to the unit while in the possession of a consumer not caused by a defect in
material or workmanship.
•
Damage caused by consumer misuse, tampering, or failure to follow the care and special handling provisions
in the instructions.
•
•
Damage to the finish of the case, or other appearance parts caused by wear.
Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna-
tional Inc.
•
Freight and Insurance cost for the warranty service.
ALL WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO
ONE-YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY. SOLEUS INTERNATIONAL INC.
DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT
SHALL SOLEUS INTERNATIONAL INC’S LIABILITY EXCEED THE RETAIL VALUE OF THE UNIT FOR
BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS UNIT.
This warranty covers only new products purchased from our authorized dealers or retailers. It does not cover used, sal-
vaged, or refurbished products.
As some states do not allow the limitation or exclusion of incidental or consequential damages, or do not allow
limitation on implied warranties, the above limitations and exclusions may not apply to you. This warranty gives you
specific legal rights, and you may also have other rights that vary from state to state.
For Technical Support and Warranty Service
Please Call (888) 876-5387
Or Write To:
Soleus International Inc.
20035 E. Walnut Dr. N.
City of Industry, CA 91789 USA
14
Download from Www.Somanuals.com. All Manuals Search And Download.
|